Emma uploaded a new version of File:Fse-critical-heat-flux-for-ignition-v2.svg |
m Remove source references from file description |
||
| Line 1: | Line 1: | ||
== Summary == | == Summary == | ||
The critical flux is the horizontal-axis intercept of the fitted model. The illustrated line uses red oak parameters | The critical flux is the horizontal-axis intercept of the fitted model. The illustrated line uses red oak parameters. | ||
Original illustration for [[Critical heat flux for ignition]], level 3 Advanced. | Original illustration for [[Critical heat flux for ignition]], level 3 Advanced. | ||
* Alt text: Calculated inverse-square-root ignition time against heat flux, extrapolated to an intercept at 10 kW/m². | * Alt text: Calculated inverse-square-root ignition time against heat flux, extrapolated to an intercept at 10 kW/m². | ||
* Accuracy notes: Label extrapolation clearly; do not draw a negative-time or below-threshold branch. Use the NUREG parameter convention. | * Accuracy notes: Label extrapolation clearly; do not draw a negative-time or below-threshold branch. Use the NUREG parameter convention. | ||
Latest revision as of 08:48, 13 November 2026
Summary
The critical flux is the horizontal-axis intercept of the fitted model. The illustrated line uses red oak parameters.
Original illustration for Critical heat flux for ignition, level 3 Advanced.
- Alt text: Calculated inverse-square-root ignition time against heat flux, extrapolated to an intercept at 10 kW/m².
- Accuracy notes: Label extrapolation clearly; do not draw a negative-time or below-threshold branch. Use the NUREG parameter convention.
Licensing
New drawing by Fire Safety Academy. © Fire Safety Academy.
File history
Click on a date/time to view the file as it appeared at that time.
| Date/Time | Thumbnail | Dimensions | User | Comment | |
|---|---|---|---|---|---|
| current | 16:12, 2 November 2026 | 900 × 600 (12 KB) | Emma (talk | contribs) | Watermark: Fire Safety Academy logo icon, 70 px, 45 % opacity | |
| 07:26, 2 November 2026 | 900 × 600 (10 KB) | Emma (talk | contribs) | Level 3 visual plan: fse-critical-heat-flux-for-ignition-v2.svg |
You cannot overwrite this file.