== Summary ==
== Summary ==
The critical flux is the horizontal-axis intercept of the fitted model. The illustrated line uses red oak parameters. Based on Iqbal and Salley (2004), pp. 6-5–6-6.
The critical flux is the horizontal-axis intercept of the fitted model. The illustrated line uses red oak parameters.


Original illustration for [[Critical heat flux for ignition]], level 3 Advanced.
Original illustration for [[Critical heat flux for ignition]], level 3 Advanced.


* Source basis: Iqbal and Salley (2004), p. 6-5, Eq. 6-2, and p. 6-6, Table 6-3; redraw, do not copy.
* Alt text: Calculated inverse-square-root ignition time against heat flux, extrapolated to an intercept at 10 kW/m².
* Alt text: Calculated inverse-square-root ignition time against heat flux, extrapolated to an intercept at 10 kW/m².
* Accuracy notes: Label extrapolation clearly; do not draw a negative-time or below-threshold branch. Use the NUREG parameter convention.
* Accuracy notes: Label extrapolation clearly; do not draw a negative-time or below-threshold branch. Use the NUREG parameter convention.

Latest revision as of 08:48, 13 November 2026

Summary

The critical flux is the horizontal-axis intercept of the fitted model. The illustrated line uses red oak parameters.

Original illustration for Critical heat flux for ignition, level 3 Advanced.

  • Alt text: Calculated inverse-square-root ignition time against heat flux, extrapolated to an intercept at 10 kW/m².
  • Accuracy notes: Label extrapolation clearly; do not draw a negative-time or below-threshold branch. Use the NUREG parameter convention.

Licensing

New drawing by Fire Safety Academy. © Fire Safety Academy.

File history

Click on a date/time to view the file as it appeared at that time.

Date/TimeThumbnailDimensionsUserComment
current16:12, 2 November 2026Thumbnail for version as of 16:12, 2 November 2026900 × 600 (12 KB)Emma (talk | contribs)Watermark: Fire Safety Academy logo icon, 70 px, 45 % opacity
07:26, 2 November 2026Thumbnail for version as of 07:26, 2 November 2026900 × 600 (10 KB)Emma (talk | contribs)Level 3 visual plan: fse-critical-heat-flux-for-ignition-v2.svg

The following page uses this file:

Metadata