== Summary ==
== Summary ==
Left: one detection system controls four functions, so its failure removes all of them. Right: revised design with early automatic suppression and smoke doors on local detectors. Based on Australian Building Codes Board (2020b), p. 100.
Left: one detection system controls four functions, so its failure removes all of them. Right: revised design with early automatic suppression and smoke doors on local detectors.


Original illustration for [[Common cause failure]], level 4 Expert.
Original illustration for [[Common cause failure]], level 4 Expert.


* Source basis: Australian Building Codes Board (2020b), p. 100 (example: detection system raises alarm, activates smoke control, alerts fire brigade, releases hold-open smoke doors; total failure probability about 20 %; redesign with early automatic suppression in lieu of active smoke control and smoke doors on local detectors independent of the main system, detection system retained)
* Alt text: Two panels: left, one detection system feeds alarm, brigade call, smoke control and smoke doors; right, sprinklers and local door detectors added.
* Alt text: Two panels: left, one detection system feeds alarm, brigade call, smoke control and smoke doors; right, sprinklers and local door detectors added.


== Licensing ==
== Licensing ==
New drawing by Fire Safety Academy. © Fire Safety Academy.
New drawing by Fire Safety Academy. © Fire Safety Academy.

Latest revision as of 08:46, 13 November 2026

Summary

Left: one detection system controls four functions, so its failure removes all of them. Right: revised design with early automatic suppression and smoke doors on local detectors.

Original illustration for Common cause failure, level 4 Expert.

  • Alt text: Two panels: left, one detection system feeds alarm, brigade call, smoke control and smoke doors; right, sprinklers and local door detectors added.

Licensing

New drawing by Fire Safety Academy. © Fire Safety Academy.