Hardware must fit as well. Tutterow (2008) writes that the need for standard fire service connections is most apparent during mutual-aid operations. Where hose couplings, nozzles and other equipment do not conform to the standards, adapters are needed, which complicates fire-fighting operations; NFPA 1963 covers these connections.<ref name="Tutterow-12-286">Tutterow (2008), p. 12-286.</ref> The auxiliary 2½ in. (64 mm) intake on a pumper is one means of connecting a supply line in mutual-aid operations if the hose connections for the large intake are not compatible.<ref name="Tutterow-12-273">Tutterow (2008), p. 12-273.</ref> Fires sometimes need more water-carrying capacity than one department has, and for that case Stewart (2008) calls a sound mutual-aid or automatic-aid programme necessary and far superior to makeshift, unsafe equipment.<ref name="Stewart-13-48">Stewart (2008), p. 13-48.</ref> | Hardware must fit as well. Tutterow (2008) writes that the need for standard fire service connections is most apparent during mutual-aid operations. Where hose couplings, nozzles and other equipment do not conform to the standards, adapters are needed, which complicates fire-fighting operations; NFPA 1963 covers these connections.<ref name="Tutterow-12-286">Tutterow (2008), p. 12-286.</ref> The auxiliary 2½ in. (64 mm) intake on a pumper is one means of connecting a supply line in mutual-aid operations if the hose connections for the large intake are not compatible.<ref name="Tutterow-12-273">Tutterow (2008), p. 12-273.</ref> Fires sometimes need more water-carrying capacity than one department has, and for that case Stewart (2008) calls a sound mutual-aid or automatic-aid programme necessary and far superior to makeshift, unsafe equipment.<ref name="Stewart-13-48">Stewart (2008), p. 13-48.</ref> | ||
[[File:fse-mutual-aid-v5.jpg|thumb|upright=1.5|alt=Two fire hose couplings of different types joined by a coupling adapter|A coupling adapter joining two different fire hose connections. Non-matching couplings make adapters necessary when departments work together.]] | |||
Mutual aid also enters planning before an incident. Serapiglia (2008) notes that company assignments in pre-incident plans based on the probable order of arrival, including neighbouring companies on automatic mutual aid, can make fireground operations more effective.<ref name="Serapiglia-12-297">Serapiglia (2008), p. 12-297.</ref> If an automatic response agreement means that a mutual-aid department arrives first, that department should take part in the planning and receive copies of the finished plan.<ref name="Serapiglia-12-298">Serapiglia (2008), p. 12-298.</ref> In call and volunteer departments, senior fire fighters who cannot respond regularly to first alarms may be assigned to guide mutual-aid companies when serious fires occur.<ref name="Denlinger-12-75">Denlinger (2008), p. 12-75.</ref> | Mutual aid also enters planning before an incident. Serapiglia (2008) notes that company assignments in pre-incident plans based on the probable order of arrival, including neighbouring companies on automatic mutual aid, can make fireground operations more effective.<ref name="Serapiglia-12-297">Serapiglia (2008), p. 12-297.</ref> If an automatic response agreement means that a mutual-aid department arrives first, that department should take part in the planning and receive copies of the finished plan.<ref name="Serapiglia-12-298">Serapiglia (2008), p. 12-298.</ref> In call and volunteer departments, senior fire fighters who cannot respond regularly to first alarms may be assigned to guide mutual-aid companies when serious fires occur.<ref name="Denlinger-12-75">Denlinger (2008), p. 12-75.</ref> | ||
Revision as of 09:34, 8 November 2026
Mutual aid is the arrangement under which neighbouring fire departments help one another when a major emergency or several simultaneous events overwhelm the response capacity of one department.[1] In the United States and Canada, as described in the 2008 NFPA Fire Protection Handbook, mutual-aid plans set out how help is requested and dispatched, so that each party knows what is expected.[2] Its forms include help sent on request to a large fire, automatic aid on the first alarm, joint response along common boundaries, and paid "outside aid" contracts.[2][3]
Even the largest jurisdictions rely to some extent on mutual aid from surrounding areas to provide resources for Firefighting.[4] For disasters it extends to statewide mutual aid legislation and to the Emergency Management Assistance Compact (EMAC) between US states.[2][5] In 2004, mutual aid made up 4% of the calls handled by US fire departments.[6] The handbook authors present mutual aid as a relatively easy way to add capacity, not as a substitute for adequate local resources.[7][3] They advise agreeing beforehand on command, procedures, communications and equipment, because differences in these can hamper joint operations.[2]
Definition and forms
Denlinger (2008) describes mutual aid as a tradition among neighbouring fire departments of helping each other when one department is overwhelmed.[1] "True mutual aid", in her words, is a relationship in which each member is prepared to assist the other parties to the agreement.[2] The incident command manual of the Fire Department of the City of New York (FDNY), reproduced by NIST, defines mutual aid as documents between the city and surrounding communities. In them the parties agree to assist one another on request with personnel and equipment in an emergency.[8] Mutual aid may also extend beyond emergency response into shared training facilities, apparatus purchase and long-range planning.[1] Denlinger treats it as one element of Fire department organisation, next to communications and staffing.[9]
Denlinger lists five things a mutual-aid plan may provide.[2] These are an immediate joint response of several departments to high-risk properties, and a joint response to alarms near the boundaries between department areas. A plan may also arrange cover of a department's area by outside departments while the local resources are engaged elsewhere. The last two are extra units at major fires that are too large for the local department, and specialised fire-fighting equipment that is not available locally in adequate quantity.[2] Granito (2008) names two boundary arrangements. "Line response" is a joint response along common boundaries to high-risk hazards, and "closest station response" sends the nearest station by prearrangement even when the address lies in another district.[3]
Some communities have adopted automatic reciprocal aid agreements, under which two or more departments are dispatched through one 9-1-1 communications centre as though they were a single department.[2] Denlinger calls this a "total boundary drop" that treats all the jurisdictions concerned as one and optimises the response for the citizens of the area. It usually saves taxpayers money as well, because it removes the need for several communications centres. Some jurisdictions have gone further and pooled or merged their resources into an integrated system with standardised training, shared facilities, joint purchases of specialised apparatus and coordinated long-range planning.[2] Granito calls such cooperation without loss of autonomy "functional consolidation", ranging from joint dispatch and stations to group purchasing and regional special response teams.[3]
Outside aid is a different arrangement. Communities or individual properties known to be deficient in fire-fighting resources contract in advance to pay another jurisdiction for certain fire-fighting assistance.[2] In some of these "outside aid programs" the contract covers the basic first-alarm response, and in others it covers additional help at major fires. Denlinger also notes that, in most areas of the United States, larger fire departments are willing to assist smaller jurisdictions on request at major incidents that exceed local capabilities.[2]
Why fire departments rely on mutual aid
Granito (2008) distinguishes two concepts in evaluating a fire department.[7] Capability is the ability to arrive within a short time with enough trained personnel and equipment to rescue trapped occupants and confine the fire to the room or building of origin on initial attack. Capacity is the ability to respond adequately to multiple-alarm incidents ("sustained attacks") and to simultaneous calls of any type. According to Granito, in many areas it is relatively easy to increase capacity through mutual aid and shift callbacks, but much more difficult to improve capability, which requires an immediate response of nearby forces. The techniques he lists for mitigating both handicaps include automatic, immediate mutual-aid response from nearby departments and elaborate regional mutual-aid agreements. One question he proposes for a local response evaluation is how many minutes mutual aid takes to arrive.[7]
Denlinger (2008) writes that mutual aid plays an important role in providing additional resources and that some departments use automatic mutual aid on the initial response.[4] Even large cities were making increased use of regularly assigned and automatic mutual aid. This is practical when a neighbouring department's companies are much nearer to an incident than the city's own, and vice versa. Her staffing example is that a large city may operate one engine company per 15,000 to 20,000 population and still have many well-distributed companies. A city of 30,000, by contrast, might not be able to muster an effective fire-fighting force with only two engine companies.[4]
Staffing costs push in the same direction. The requirement to pay overtime has improved mutual-aid arrangements, because on-duty companies from nearby departments respond much faster than off-duty local personnel called back in. Relying on them also keeps overtime costs down.[10] Granito notes that it may take 30 minutes or more to put reserve apparatus into service with recalled personnel.[3] Where personnel suffice for routine fires but not for major emergencies, he advises calling back off-shift personnel and promptly calling nearby departments for mutual aid. For volunteer departments short of response personnel, he lists automatic mutual-aid agreements among several methods that may be used to produce response crews.[3]
Specialised resources are a further reason. Granito lists vehicles for hazardous materials, heavy and specialised rescue (including boats), lighting, breathing apparatus bottles and emergency medical response; where these cannot be made available locally, mutual-aid arrangements are needed.[11] Additional alarms at a large fire may involve the immediate use of mutual-aid companies until local forces are supplemented with off-duty personnel.[12] For rescue work, R. Wright (2008) describes the use of mutual-aid agencies to augment daily fire, rescue and emergency medical alarm assignments as commonplace in many jurisdictions.[13]
The NFPA National Fire Experience Survey gives an idea of the volume. In 2004, US fire departments handled 22,616,500 calls, of which 4% were mutual aid, 7% fires, 9% false alarms and 62% medical aid.[6] As an illustration, 4% of that total is roughly 900,000 mutual-aid calls in one year, an approximate number because the share is rounded. Hall and Cote (2008) add that the potential to overload a department's total resources still came mainly from fires, although fires were only about 1 in 14 calls.[6]
Agreements and their content
In all cases of mutual aid and outside aid, Denlinger (2008) advises that carefully worded agreements be made in advance, in line with the legal requirements for fire department operations outside the normal jurisdiction.[2] Local departments may differ in operating methods and types of equipment, which could hamper coordination if no well-constructed agreement is in place. Command responsibility, jurisdictional questions, insurance coverage and legal constraints should be covered in written agreements and supported by enabling legislation. Plans should also specify that the National Incident Management System (NIMS) and the Incident command system (ICS) will be used at all incidents. They should also cover standard operating procedures, interdepartmental communications, maps and adaptors.[2]
An agreement need not oblige a party to strip its own area. The parties may choose to give assistance only to the extent that they can do so without seriously reducing local protection, so the plan should identify and address any weaknesses in coverage.[2] Denlinger regards an extensive, region-wide agreement that maintains and optimises coverage for all jurisdictions as the ideal plan. According to her, most states and provinces had large-area disaster plans coordinated under NIMS, which form a natural basis for smaller, routine plans.[2]
Setting up and maintaining agreements for each jurisdiction can be a significant administrative burden.[2] State legislation that provides mutual aid between all jurisdictions and emergency service agencies in the state can reduce this burden, and it can be written so that individual communities or agencies may opt out. Denlinger calls the regional planning and cooperation that this promotes the cornerstone of successful disaster response. She also recommends checking that interstate agreements release resources within hours of a request.[2]
Similar rules apply outside the public fire service. For private organisations, Schmidt (2008) states that mutual aid agreements should be in writing, reviewed by legal counsel and signed by an authorised manager.[14] They should define liability, funding and cost arrangements, as well as authority, roles, responsibilities, procedures, communications, resources and required qualifications.[14] For technical rescue, R. Wright (2008) lists mutual-aid agreements alongside memoranda of agreement and service contracts, all to be reviewed by legal counsel for liability.[15]
Working together at an incident
Joint operations depend on shared procedures. Klaene and Sanders (2008) note that large incidents often require more resources than a single fire department can provide.[16] This makes standard operating procedures for incident management, accountability and rapid intervention crews especially important at such scenes. When mutual-aid operations are likely, all responding departments should use the same procedures and conduct joint training so that operations on scene are safe and predictable.[16] Laughlin (2008) quotes a recommendation from fatality investigations by the National Institute for Occupational Safety and Health (NIOSH). It reads: "Train on the SOPs, the incident command system, and lost firefighter procedures with mutual aid departments to establish interagency knowledge of equipment, procedures, and capabilities."[17]
Radio communications are a second condition. Regional communications plans are essential when units from several jurisdictions work together, and they may specify dedicated frequencies or equipment that lets different systems communicate.[18] Merklinger (2008) states that adjacent agencies with similar missions should share a common mutual-aid radio channel, provided for by the Federal Communications Commission and usually managed statewide.[19] Responding fire department vehicles need radios that also work on the shared mutual-aid frequencies.[20] Describing the 2001 attack on the World Trade Center, an FDNY interviewee told NIST investigators that private ambulance teams did not have the same radios. Those that were part of the emergency medical services and mutual aid system did have working radios.[21]
Hardware must fit as well. Tutterow (2008) writes that the need for standard fire service connections is most apparent during mutual-aid operations. Where hose couplings, nozzles and other equipment do not conform to the standards, adapters are needed, which complicates fire-fighting operations; NFPA 1963 covers these connections.[22] The auxiliary 2½ in. (64 mm) intake on a pumper is one means of connecting a supply line in mutual-aid operations if the hose connections for the large intake are not compatible.[23] Fires sometimes need more water-carrying capacity than one department has, and for that case Stewart (2008) calls a sound mutual-aid or automatic-aid programme necessary and far superior to makeshift, unsafe equipment.[24]

Mutual aid also enters planning before an incident. Serapiglia (2008) notes that company assignments in pre-incident plans based on the probable order of arrival, including neighbouring companies on automatic mutual aid, can make fireground operations more effective.[25] If an automatic response agreement means that a mutual-aid department arrives first, that department should take part in the planning and receive copies of the finished plan.[26] In call and volunteer departments, senior fire fighters who cannot respond regularly to first alarms may be assigned to guide mutual-aid companies when serious fires occur.[27]
Mutual aid in disasters
In US Emergency management, the scale of a disaster determines how far mutual aid reaches. Van Helden and Stewart (2008) describe three levels.[28] Minor disasters, such as multiple wildland fires, a flood or a blizzard, require local and possibly regional resources, and local mutual aid agreements are critical. Major disasters exceed local and regional capabilities and require state and federal help, supported by interlocal and regional agreements that may include several states. Catastrophic disasters require substantial state and federal assistance with military involvement.[28]
The same authors divide mutual aid agreements for disasters into three categories.[5] The first is EMAC, an interstate agreement that allows states to help one another in all types of disaster and is managed by the National Emergency Management Association. The second is intrastate mutual aid legislation, relatively new in 2008, which allows aid across the political subdivisions of a state and had been modelled successfully in several states. The third is a state and county agreement that allows local emergency responders to be deployed under the auspices of EMAC.[5] The authors encourage all government entities to take part in EMAC, which allows the timely redistribution of resources across state lines.[29]
Disaster plans at state, regional, local and department level must work in concert, especially for requests for additional resources through mutual aid.[30] A request for mutual aid depends on the resources and needs of the community, and support from state and federal bodies is not automatic.[30] Local governments are advised to have critical ordinances drafted in advance, including one that activates local mutual aid agreements.[31]
Requests are clearer when resources are typed. Within NIMS, resources such as fire fighting, law enforcement and public works are defined by kind and type. A request for something as simple as a generator should therefore state its type, size, fuel and electrical hookup. The authors described resource typing in 2008 as a work in progress.[29]
Wildland fire suppression in the United States uses a tiered form of the same idea. Smalley (2008) describes a three-tier system of support: the local area, one of 11 geographic areas, and the national level.[32] When a fire is reported, the local agency and its fire-fighting partners respond. If the fire keeps growing, the agency can ask its geographic area for help, and when an area has exhausted its resources it can turn to the National Interagency Coordination Center in Boise, Idaho.[32] When national resources such as smoke jumpers, air tankers or Type 1 incident management teams are critically short, the National Multi-Agency Coordination Group sets priorities and allocates them.[33]
The World Trade Center attack of 11 September 2001 shows mutual aid in a large urban emergency. Before the attack, FDNY maintained agreements for two-way support with neighbouring jurisdictions, including Nassau and Westchester Counties, Jersey City and the cities of Mount Vernon and Yonkers.[34] Members of FDNY had historically responded to alarms in other municipalities, and the other departments had done the same in New York.[34] The NIST timeline records that mutual aid was requested from Westchester County at 10:07.[35] A request to Nassau County followed at 10:23, with directions on staging areas.[36]
Industrial sites and special facilities
Mutual aid is not limited to public fire departments. Schmidt (2008) describes mutual aid agreements with organisations that have similar facilities, systems or equipment as one means of responding to an emergency or restarting business after a loss.[14] Neighbouring facilities, businesses or even competitors may provide personnel, equipment or supplies for fires and other emergencies. According to Schmidt, this is common with high-hazard industrial facilities that are located far from capable public fire suppression services. Such agreements can also keep critical functions going by sharing facilities, machinery and equipment, or by producing common products.[14]
An appendix on selected fires at US commercial nuclear power plants, in a US Nuclear Regulatory Commission report on fire dynamics tools, describes onsite brigades calling in offsite fire departments. At Shearon Harris on 9 October 1989, the plant contacted offsite fire departments shortly after a fire at a main transformer and the main generator began. The plant operator later credited this prompt notification with limiting the damage.[37] At San Onofre Unit 3 on 3 February 2001, the onsite fire department arrived within 7 minutes and its captain requested additional support from an offsite fire department.[38]
At Waterford Unit 3 on 10 June 1995, the offsite fire department was summoned at 9:41 a.m. and arrived about 17 minutes later.[39] It recommended water, but the plant's shift supervisor decided to continue with other agents. Water was permitted about 90 minutes after the fire started, and the fire was brought under control within 4 minutes of its application.[39]
Airports also receive mutual aid from the surrounding cities. Kreckie (2008) points out that in a multiple-hit terrorist scenario, additional events may occur in the cities outside the airport. These are the same cities that provide mutual aid to the airport, so in such cases "there may be no help coming".[40]
Limits of mutual aid
The handbook authors set clear limits on what mutual aid can do. Granito (2008) states that mutual aid or mutual response should not be relied on for routine emergencies, because there could be times when local commitments prevent the expected assistance.[3] Mutual-aid agreements do not reduce the responsibility of each jurisdiction to maintain adequate facilities for its normal fire protection needs. Granito also writes that teamwork and tactical efficiency must be assumed to be somewhat lower than for equal units from the same department under a united command.[3] "Doing more with less" was a popular concept, but in his view it has limits.[7]
A second limit is that help may not be available when it is most needed. Each party may restrict its assistance to what it can give without seriously reducing its own protection.[2] For a pandemic flu affecting the whole country, Van Helden and Stewart expect that local governments would have to plan to operate without state and federal help.[28] The airport case shows the same weakness at a smaller scale, where the departments that normally provide help may be engaged by the same event.[40]
See also
- Fire company staffing
- Standards of cover
- Fire service radio communications
- Pre-incident planning
- Industrial fire brigade
Notes
- ↑ 1.0 1.1 1.2 Denlinger (2008), p. 12-52.
- ↑ 2.00 2.01 2.02 2.03 2.04 2.05 2.06 2.07 2.08 2.09 2.10 2.11 2.12 2.13 2.14 2.15 2.16 2.17 Denlinger (2008), p. 12-65.
- ↑ 3.0 3.1 3.2 3.3 3.4 3.5 3.6 3.7 Granito (2008), p. 12-13.
- ↑ 4.0 4.1 4.2 Denlinger (2008), p. 12-72.
- ↑ 5.0 5.1 5.2 Van Helden and Stewart (2008), p. 12-208.
- ↑ 6.0 6.1 6.2 Hall and Cote (2008), p. 3-28.
- ↑ 7.0 7.1 7.2 7.3 Granito (2008), p. 12-8.
- ↑ Lawson and Vettori (2005), Appendix A.
- ↑ Denlinger (2008), p. 12-51.
- ↑ Denlinger (2008), p. 12-74.
- ↑ Granito (2008), p. 12-11.
- ↑ Granito (2008), p. 12-12.
- ↑ R. Wright (2008), p. 13-16.
- ↑ 14.0 14.1 14.2 14.3 Schmidt (2008), p. 1-142.
- ↑ R. Wright (2008), p. 13-18.
- ↑ 16.0 16.1 Klaene and Sanders (2008), p. 13-4.
- ↑ Laughlin (2008), p. 12-164.
- ↑ Denlinger (2008), p. 12-66.
- ↑ Merklinger (2008), p. 12-257.
- ↑ Tutterow (2008), p. 12-279.
- ↑ Lawson and Vettori (2005), p. 66.
- ↑ Tutterow (2008), p. 12-286.
- ↑ Tutterow (2008), p. 12-273.
- ↑ Stewart (2008), p. 13-48.
- ↑ Serapiglia (2008), p. 12-297.
- ↑ Serapiglia (2008), p. 12-298.
- ↑ Denlinger (2008), p. 12-75.
- ↑ 28.0 28.1 28.2 Van Helden and Stewart (2008), p. 12-209.
- ↑ 29.0 29.1 Van Helden and Stewart (2008), p. 12-205.
- ↑ 30.0 30.1 Van Helden and Stewart (2008), p. 12-202.
- ↑ Van Helden and Stewart (2008), p. 12-203.
- ↑ 32.0 32.1 Smalley (2008), p. 13-68.
- ↑ Smalley (2008), p. 13-69.
- ↑ 34.0 34.1 Keough and Grill (2005), p. 13.
- ↑ Lawson and Vettori (2005), p. 224.
- ↑ Lawson and Vettori (2005), p. 227.
- ↑ Iqbal and Salley (2004), p. H-18.
- ↑ Iqbal and Salley (2004), p. H-26.
- ↑ 39.0 39.1 Iqbal and Salley (2004), p. H-21.
- ↑ 40.0 40.1 Kreckie (2008), p. 13-113.
References
- Denlinger, R. F. (2008). Managing fire-rescue departments. In A. E. Cote, C. C. Grant, J. R. Hall, Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 12-51–12-78). National Fire Protection Association.
- Granito, J. A. (2008). Planning for public fire-rescue protection. In A. E. Cote, C. C. Grant, J. R. Hall, Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 12-3–12-22). National Fire Protection Association.
- Hall, J. R., Jr., & Cote, A. E. (2008). An overview of the fire problem and fire protection. In A. E. Cote, C. C. Grant, J. R. Hall, Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 3-3–3-30). National Fire Protection Association.
- Iqbal, N., & Salley, M. H. (2004). Fire Dynamics Tools (FDTs): Quantitative fire hazard analysis methods for the U.S. Nuclear Regulatory Commission Fire Protection Inspection Program (NUREG-1805). U.S. Nuclear Regulatory Commission, Office of Nuclear Reactor Regulation.
- Keough, R. J., & Grill, R. A. (2005). Fire alarm systems (NIST NCSTAR 1-4C). National Institute of Standards and Technology.
- Klaene, B. J., & Sanders, R. (2008). Fireground operations. In A. E. Cote, C. C. Grant, J. R. Hall, Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 13-3–13-11). National Fire Protection Association.
- Kreckie, J. (2008). Aircraft rescue and fire fighting (ARFF). In A. E. Cote, C. C. Grant, J. R. Hall, Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 13-99–13-115). National Fire Protection Association.
- Laughlin, J. W. (2008). Training programs for fire and emergency service personnel. In A. E. Cote, C. C. Grant, J. R. Hall, Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 12-161–12-175). National Fire Protection Association.
- Lawson, J. R., & Vettori, R. L. (2005). The emergency response operations (NIST NCSTAR 1-8). National Institute of Standards and Technology.
- Merklinger, J. M. (2008). Public emergency services alarm, dispatch, and communications systems. In A. E. Cote, C. C. Grant, J. R. Hall, Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 12-253–12-266). National Fire Protection Association.
- Schmidt, D. L. (2008). Emergency management and business continuity. In A. E. Cote, C. C. Grant, J. R. Hall, Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 1-137–1-156). National Fire Protection Association.
- Serapiglia, M. J. (2008). Pre-Incident planning for industrial and municipal emergency response. In A. E. Cote, C. C. Grant, J. R. Hall, Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 12-289–12-298). National Fire Protection Association.
- Smalley, J. C. (2008). Wildland fire management. In A. E. Cote, C. C. Grant, J. R. Hall, Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 13-53–13-79). National Fire Protection Association.
- Stewart, L. J. (2008). Alternate water supplies. In A. E. Cote, C. C. Grant, J. R. Hall, Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 13-37–13-52). National Fire Protection Association.
- Tutterow, R. (2008). Fire department apparatus and equipment. In A. E. Cote, C. C. Grant, J. R. Hall, Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 12-267–12-287). National Fire Protection Association.
- Van Helden, W., & Stewart, T. (2008). Disaster planning and response services. In A. E. Cote, C. C. Grant, J. R. Hall, Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 12-199–12-214). National Fire Protection Association.
- Wright, R. (2008). Organizing rescue operations. In A. E. Cote, C. C. Grant, J. R. Hall, Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 13-13–13-21). National Fire Protection Association.