The fire propagation apparatus: a specimen on a load cell inside a quartz tube is heated by four infrared heaters while an oxygen and nitrogen mixture flows upwards; products are collected and analysed in the exhaust. Left: horizontal specimen for ignition and combustion tests; right: vertical specimen for fire propagation tests. Based on Tewarson (2002), p. 3-84 and Janssens (2002), p. 3-54.
Original illustration for Fire propagation apparatus.
- Source basis: Tewarson (2002), p. 3-84, Figures 3-4.2(a) and (b) (redraw, do not copy); Janssens (2002), p. 3-54 (tube dimensions, heaters, pilot, gas supply, orifice); Madrzykowski and Stroup (2008), pp. 2-38–2-39, 2-44 (tungsten-quartz heaters, Figure 2.3.7 and 2.3.8, HeNe laser smoke measurement); Tewarson (2002), p. 3-92 (vertical sample, ignition zone 120–200 mm)
- Alt text: Schematic of the fire propagation apparatus: specimen on a load cell in a quartz tube, four infrared heaters, gas inlet below, hood and exhaust duct above.
Licensing
New drawing by Fire Safety Academy. © Fire Safety Academy.
File history
Click on a date/time to view the file as it appeared at that time.
| Date/Time | Thumbnail | Dimensions | User | Comment | |
|---|---|---|---|---|---|
| current | 08:28, 8 November 2026 | 1,800 × 1,270 (16 KB) | Lisa (talk | contribs) | Watermark: Fire Safety Academy logo icon, 70 px, 45 % opacity | |
| 08:15, 8 November 2026 | 1,450 × 1,069 (14 KB) | Lisa (talk | contribs) | Watermark: Fire Safety Academy logo icon, 70 px, 45 % opacity |