Summary

Arrangement of the UL 94 vertical burning test: a 125 mm by 13 mm strip is clamped upright, a 50 W flame is applied to its lower end for 10 s, and loose cotton 30 cm below catches any flaming drops. Based on Madrzykowski and Stroup (2008), p. 2-42 and Hirschler (2008a), p. 6-41.

Original illustration for UL 94 flammability test.

  • Source basis: Madrzykowski and Stroup (2008), p. 2-42; Hirschler (2008a), p. 6-41
  • Alt text: Side view of a plastic strip clamped vertically, a small burner flame at its lower end and a layer of cotton 30 cm below.

Licensing

New drawing by Fire Safety Academy. © Fire Safety Academy.

File history

Click on a date/time to view the file as it appeared at that time.

Date/TimeThumbnailDimensionsUserComment
current08:27, 8 November 2026Thumbnail for version as of 08:27, 8 November 20261,630 × 965 (11 KB)Lisa (talk | contribs)Watermark: Fire Safety Academy logo icon, 70 px, 45 % opacity
08:12, 8 November 2026Thumbnail for version as of 08:12, 8 November 20261,450 × 899 (9 KB)Lisa (talk | contribs)Watermark: Fire Safety Academy logo icon, 70 px, 45 % opacity

The following page uses this file: