== Meaning and terminology == | == Meaning and terminology == | ||
IDLH appears in the handbook in two related forms. Loflin describes an atmosphere as IDLH when recounting the development of United States firefighter respiratory-protection rules.<ref name="LO-110" /> Wright lists an “immediately dangerous to life and health value” among the exposure limits used to estimate harm from a hazardous-material release.<ref name="WR-134" /> The first form concerns the atmosphere encountered; the second is an item of chemical-hazard information. Neither passage supplies a numerical value for a particular substance.<ref name="LO-110" /><ref name="WR-134" /> | IDLH appears in the handbook in two related forms. Loflin describes an atmosphere as IDLH when recounting the development of United States firefighter respiratory-protection rules.<ref name="LO-110" /> Wright lists an “immediately dangerous to life and health value” among the exposure limits used to estimate harm from a hazardous-material release.<ref name="WR-134" /> The first form concerns the atmosphere encountered; the second is an item of chemical-hazard information. Neither passage supplies a numerical value for a particular substance.<ref name="LO-110" /><ref name="WR-134" /> | ||
[[File:fse-immediately-dangerous-to-life-or-health-v1.svg|thumb|upright=1.5|alt=IDLH abbreviation linked to an acute hazardous atmosphere and a chemical exposure value, with the two different expansions labelled|IDLH describes an acute atmospheric hazard and can also name an exposure value; the 2008 handbook expands the abbreviation with “and”. Based on Loflin (2008), p. 12-110 and C. J. Wright (2008a), p. 13-134.]] | |||
The title's “or” contrasts with the “and” in the handbook expansions by Loflin, Teele and Wright.<ref name="LO-110" /><ref name="TE-150" /><ref name="WR-134" /> Those chapters nevertheless use the same abbreviation for a severe atmospheric condition in respiratory protection and emergency assessment.<ref name="LO-110" /><ref name="TE-151" /><ref name="WR-134" /> The wording variation does not identify a second exposure limit.<ref name="LO-110" /><ref name="WR-134" /> | The title's “or” contrasts with the “and” in the handbook expansions by Loflin, Teele and Wright.<ref name="LO-110" /><ref name="TE-150" /><ref name="WR-134" /> Those chapters nevertheless use the same abbreviation for a severe atmospheric condition in respiratory protection and emergency assessment.<ref name="LO-110" /><ref name="TE-151" /><ref name="WR-134" /> The wording variation does not identify a second exposure limit.<ref name="LO-110" /><ref name="WR-134" /> | ||
| Line 12: | Line 13: | ||
== Different exposure limits == | == Different exposure limits == | ||
The hazardous-material worksheet in the handbook deliberately separates kinds of exposure information. It places threshold limit values and the permissible exposure limit in a group headed “non-life-threatening exposure limits”. IDLH, lethal concentration and lethal dose occupy a separate “life-threatening exposure limits” group.<ref name="WR-129">C. J. Wright (2008a), p. 13-129.</ref> These are headings on a 2008 response worksheet, not a claim that every entry within a group has the same endpoint or exposure duration.<ref name="WR-129" /><ref name="WR-134" /> | The hazardous-material worksheet in the handbook deliberately separates kinds of exposure information. It places threshold limit values and the permissible exposure limit in a group headed “non-life-threatening exposure limits”. IDLH, lethal concentration and lethal dose occupy a separate “life-threatening exposure limits” group.<ref name="WR-129">C. J. Wright (2008a), p. 13-129.</ref> These are headings on a 2008 response worksheet, not a claim that every entry within a group has the same endpoint or exposure duration.<ref name="WR-129" /><ref name="WR-134" /> | ||
[[File:fse-immediately-dangerous-to-life-or-health-v2.svg|thumb|upright=1.5|alt=Two-column schematic separating workplace exposure values from IDLH and lethal endpoints, with a distinct fire escape criterion below|The 2008 response worksheet groups workplace values separately from IDLH and lethal endpoints; fire-escape criteria address another question. Based on C. J. Wright (2008a), pp. 13-129 and 13-134 and Gann and Bryner (2008), pp. 6-18 and 6-24.]] | |||
A permissible exposure limit and a threshold limit value concern workplace exposure, whereas IDLH concerns a severe acute atmosphere in the handbook's respiratory-protection account.<ref name="WR-129" /><ref name="LO-110" /> The fire-toxicology chapter says long-term occupational values are normally of little use for the high concentrations and short exposure periods of a fire.<ref name="GB-14">Gann and Bryner (2008), p. 6-14.</ref> It would therefore be misleading to treat a workplace number as a fire-escape or emergency-entry threshold merely because all are expressed as concentrations.<ref name="GB-14" /><ref name="WR-134" /> | A permissible exposure limit and a threshold limit value concern workplace exposure, whereas IDLH concerns a severe acute atmosphere in the handbook's respiratory-protection account.<ref name="WR-129" /><ref name="LO-110" /> The fire-toxicology chapter says long-term occupational values are normally of little use for the high concentrations and short exposure periods of a fire.<ref name="GB-14">Gann and Bryner (2008), p. 6-14.</ref> It would therefore be misleading to treat a workplace number as a fire-escape or emergency-entry threshold merely because all are expressed as concentrations.<ref name="GB-14" /><ref name="WR-134" /> | ||
| Line 21: | Line 23: | ||
== Assessing an incident atmosphere == | == Assessing an incident atmosphere == | ||
In the handbook's hazardous-material procedure, the first task is to identify the material and verify information about a release. The survey records the form of the material, any leak, weather and surrounding conditions.<ref name="WR-127">C. J. Wright (2008a), p. 13-127.</ref> Material safety data sheets and response guides provide different pieces of information; the chapter states that more than one resource may be needed.<ref name="WR-127" /> Its historical comparison table lists the NIOSH Pocket Guide, the United States Coast Guard's CHRIS data and material safety data sheets as publications where an IDLH value is typically found.<ref name="WR-130">C. J. Wright (2008a), p. 13-130.</ref><ref name="WR-131">C. J. Wright (2008a), p. 13-131.</ref> | In the handbook's hazardous-material procedure, the first task is to identify the material and verify information about a release. The survey records the form of the material, any leak, weather and surrounding conditions.<ref name="WR-127">C. J. Wright (2008a), p. 13-127.</ref> Material safety data sheets and response guides provide different pieces of information; the chapter states that more than one resource may be needed.<ref name="WR-127" /> Its historical comparison table lists the NIOSH Pocket Guide, the United States Coast Guard's CHRIS data and material safety data sheets as publications where an IDLH value is typically found.<ref name="WR-130">C. J. Wright (2008a), p. 13-130.</ref><ref name="WR-131">C. J. Wright (2008a), p. 13-131.</ref> | ||
[[File:fse-immediately-dangerous-to-life-or-health-v3.svg|thumb|upright=1.5|alt=Hazardous-material assessment loop from verified substance identification through release and exposure assessment to repeated monitoring|A substance-specific exposure value is interpreted alongside the release, concentration, contact time and changing incident conditions. Based on C. J. Wright (2008a), pp. 13-127 and 13-132–13-134.]] | |||
Identification alone does not locate the hazard. Wright predicts how a containment system may breach, how its contents are released, and where a cloud, plume, stream or pool could spread.<ref name="WR-132" /> Contact may last minutes or hours, days or weeks, or longer, depending on the event and the exposure route.<ref name="WR-134" /> For a current incident, the model then considers concentrations, the duration of contact and physical as well as health hazards.<ref name="WR-134" /> This sequence explains why an IDLH value is one input to an assessment, rather than a description of the entire scene.<ref name="WR-129" /><ref name="WR-134" /> | Identification alone does not locate the hazard. Wright predicts how a containment system may breach, how its contents are released, and where a cloud, plume, stream or pool could spread.<ref name="WR-132" /> Contact may last minutes or hours, days or weeks, or longer, depending on the event and the exposure route.<ref name="WR-134" /> For a current incident, the model then considers concentrations, the duration of contact and physical as well as health hazards.<ref name="WR-134" /> This sequence explains why an IDLH value is one input to an assessment, rather than a description of the entire scene.<ref name="WR-129" /><ref name="WR-134" /> | ||
| Line 46: | Line 49: | ||
== Worked comparison: hydrogen chloride == | == Worked comparison: hydrogen chloride == | ||
Hydrogen chloride provides a documented example of how different acute criteria can be confused. In Purser's 2002 SFPE table, 200 ppm is predicted to impair escape in half a population, while 900 ppm is predicted to cause incapacitation in half.<ref name="PU-121" /> In the 2008 handbook's account of ISO 13571, the estimated incapacitating concentration is 1,000 µL/L.<ref name="GB-16" /> A microlitre per litre is numerically one part per million by volume, so the handbook's number is 1,000 ppm on the same concentration scale.<ref name="GB-14" /> The two sources use different methods and should retain their separate labels.<ref name="PU-121" /><ref name="GB-16" /> | Hydrogen chloride provides a documented example of how different acute criteria can be confused. In Purser's 2002 SFPE table, 200 ppm is predicted to impair escape in half a population, while 900 ppm is predicted to cause incapacitation in half.<ref name="PU-121" /> In the 2008 handbook's account of ISO 13571, the estimated incapacitating concentration is 1,000 µL/L.<ref name="GB-16" /> A microlitre per litre is numerically one part per million by volume, so the handbook's number is 1,000 ppm on the same concentration scale.<ref name="GB-14" /> The two sources use different methods and should retain their separate labels.<ref name="PU-121" /><ref name="GB-16" /> | ||
[[File:fse-immediately-dangerous-to-life-or-health-v4.svg|thumb|upright=1.5|alt=Logarithmic concentration scale with six hydrogen-chloride endpoints from emergency planning, fire escape and rat lethality sources|Published hydrogen-chloride criteria span different endpoints and populations; none of these plotted values is an IDLH value. Based on Purser (2002), pp. 2-121–2-122 and Gann and Bryner (2008), pp. 6-16 and 6-18.]] | |||
The SFPE incapacitation estimate divided by its escape-impairment estimate is 900/200 = 4.5. Dividing the handbook estimate by the SFPE escape-impairment estimate gives 1,000/200 = 5.<ref name="PU-121" /><ref name="GB-16" /> These ratios are simple comparisons of reported endpoints, not safety factors or an IDLH calculation. Purser also discusses one-hour Emergency Response Planning Guidelines for hydrogen chloride: 20 ppm for protection against serious effects impairing action and 100 ppm for protection against life-threatening effects.<ref name="PU-121" /><ref name="PU-122">Purser (2002), p. 2-122.</ref> Their exposure period and protective aims differ from the fire-escape estimates.<ref name="PU-121" /><ref name="PU-122" /> | The SFPE incapacitation estimate divided by its escape-impairment estimate is 900/200 = 4.5. Dividing the handbook estimate by the SFPE escape-impairment estimate gives 1,000/200 = 5.<ref name="PU-121" /><ref name="GB-16" /> These ratios are simple comparisons of reported endpoints, not safety factors or an IDLH calculation. Purser also discusses one-hour Emergency Response Planning Guidelines for hydrogen chloride: 20 ppm for protection against serious effects impairing action and 100 ppm for protection against life-threatening effects.<ref name="PU-121" /><ref name="PU-122">Purser (2002), p. 2-122.</ref> Their exposure period and protective aims differ from the fire-escape estimates.<ref name="PU-121" /><ref name="PU-122" /> | ||
Revision as of 08:19, 8 November 2026
Immediately dangerous to life or health (IDLH) describes a severe atmospheric hazard considered when people may enter a fire or hazardous-material incident. The 2008 Fire Protection Handbook expands the same abbreviation as “immediately dangerous to life and health”. The wording differs, but both phrases designate IDLH rather than two exposure limits.[1][2] In the handbook's account of United States occupational rules, an IDLH atmosphere poses an immediate hazard to life or causes immediate, irreversible, debilitating health effects.[1] The abbreviation also labels an exposure value consulted in Hazardous materials response, alongside other values with different purposes.[3]
IDLH is a designation for conditions requiring a high level of respiratory protection, rather than a description of every hazard at an incident. The handbook classifies structural fire atmospheres as IDLH because the types and quantities of combustion products are unknown.[4] It separately identifies oxygen deficiency as a reason for supplied breathing air.[2] Heat, smoke obscuration and toxic gases contribute to Fire toxicity and can affect people together.[5] Their effects vary with the fire and the person's location.[5] A reading for one gas therefore cannot, by itself, describe the whole fire atmosphere.[5][4]
Meaning and terminology
IDLH appears in the handbook in two related forms. Loflin describes an atmosphere as IDLH when recounting the development of United States firefighter respiratory-protection rules.[1] Wright lists an “immediately dangerous to life and health value” among the exposure limits used to estimate harm from a hazardous-material release.[3] The first form concerns the atmosphere encountered; the second is an item of chemical-hazard information. Neither passage supplies a numerical value for a particular substance.[1][3]
The title's “or” contrasts with the “and” in the handbook expansions by Loflin, Teele and Wright.[1][2][3] Those chapters nevertheless use the same abbreviation for a severe atmospheric condition in respiratory protection and emergency assessment.[1][4][3] The wording variation does not identify a second exposure limit.[1][3]
An IDLH designation is tied to exposure conditions. Wright's incident model first identifies a substance and its release, then considers dispersion, concentration, contact time and the kind of harm expected.[6][3] The same chemical can produce different concentrations as a plume moves or ventilation changes; the model is revised when new information becomes available.[6][3] The presence of a named chemical alone does not supply the concentration or duration needed to interpret a substance-specific limit.[3]
Different exposure limits
The hazardous-material worksheet in the handbook deliberately separates kinds of exposure information. It places threshold limit values and the permissible exposure limit in a group headed “non-life-threatening exposure limits”. IDLH, lethal concentration and lethal dose occupy a separate “life-threatening exposure limits” group.[7] These are headings on a 2008 response worksheet, not a claim that every entry within a group has the same endpoint or exposure duration.[7][3]
A permissible exposure limit and a threshold limit value concern workplace exposure, whereas IDLH concerns a severe acute atmosphere in the handbook's respiratory-protection account.[7][1] The fire-toxicology chapter says long-term occupational values are normally of little use for the high concentrations and short exposure periods of a fire.[8] It would therefore be misleading to treat a workplace number as a fire-escape or emergency-entry threshold merely because all are expressed as concentrations.[8][3]
An LC50 is a different endpoint again. The handbook gives 30-minute rat LC50 values for several combustion products, including 3,800 µL/L for hydrogen chloride in Table 6.2.1.[9] That table concerns lethality in an animal test, not the concentration at which a person could escape or a responder could enter without respiratory protection.[9][10] Even the handbook's equation on the same page prints 3,700 µL/L for hydrogen chloride, illustrating that the source's own model and table do not use an identical input.[9] Neither number is labelled an IDLH value there.[9]
Fire-tenability criteria address a further question: when conditions impair escape or produce incapacitation. The handbook's model treats the effects of asphyxiant gases as an accumulated dose, but treats initial sensory irritation mainly as a function of the concentration at that moment.[11] The endpoint is the ability to escape from a fire, not the classification of a responder's respiratory equipment.[9][4] A numerical comparison is useful only when the endpoint, exposed population, exposure time and units remain attached to every value.[9][12]
Assessing an incident atmosphere
In the handbook's hazardous-material procedure, the first task is to identify the material and verify information about a release. The survey records the form of the material, any leak, weather and surrounding conditions.[13] Material safety data sheets and response guides provide different pieces of information; the chapter states that more than one resource may be needed.[13] Its historical comparison table lists the NIOSH Pocket Guide, the United States Coast Guard's CHRIS data and material safety data sheets as publications where an IDLH value is typically found.[14][15]
Identification alone does not locate the hazard. Wright predicts how a containment system may breach, how its contents are released, and where a cloud, plume, stream or pool could spread.[6] Contact may last minutes or hours, days or weeks, or longer, depending on the event and the exposure route.[3] For a current incident, the model then considers concentrations, the duration of contact and physical as well as health hazards.[3] This sequence explains why an IDLH value is one input to an assessment, rather than a description of the entire scene.[7][3]
The handbook lists several ways to estimate airborne concentrations: colourimetric tubes, a carbon-monoxide meter, an oxygen meter, a combustible-gas meter, a photoionisation detector and personal monitoring equipment.[3] The choice of instrument depends on its limitations, and results must be recorded and interpreted.[3] An odour may offer a clue, but Wright warns that using it to judge concentration is itself risky.[3] Monitoring can also help identify an unknown material, although the chapter describes that as possible only in some cases.[3]
The assessment is repeated as the situation develops. Wright calls for predictions of the area exposed, the number of people and other assets within it, and the likely harm under the current conditions.[3] Weather, topography, release rate, barriers and dispersal all affect the result.[6][3] When incident conditions change, the chapter says the analysis information must be reviewed and updated.[3] A single concentration reading made earlier in a changing release therefore has a limited scope.[3]
Respiratory protection and entry
The 2008 handbook describes United States rules and NFPA standards that require Self-contained breathing apparatus (SCBA) for firefighting other than wildland operations, and for emergency operations where IDLH or oxygen-deficient atmospheres exist or are expected.[2] Its examples include structural firefighting, hazardous-material incidents, confined-space rescue and certain technical rescue work.[2] SCBA carries its own breathing-air supply, unlike a supplied-air respirator whose air source is not carried by the wearer.[2][4] This account is limited to the United States and the standards described in the 2008 handbook.[2][4]
The same chapter says that US OSHA regulations and NFPA standards, as it describes them, specify positive-pressure SCBA in IDLH or potentially IDLH atmospheres.[4] Positive pressure is maintained in the facepiece during inhalation and exhalation to reduce inward leakage.[4] Demand SCBA instead relies on negative pressure during inhalation, creating a risk that contaminated ambient air enters the mask, so the cited account excludes it for these operations.[4] Positive pressure does not substitute for a proper face seal and fit test.[4]
Equipment is only one part of entry control. For the initial stage of a working structure fire, Loflin reports an NFPA 1500 example with four people.[16] Two work inside the hazardous area and two remain outside, available for assistance or rescue.[16] The outside members track who entered, their location, work and entry time, while maintaining contact with the inside crew.[16] The example has this specific initial-crew scope; it is not a universal staffing formula for every hazardous-material incident.[16]
Fire smoke and oxygen loss
Fire atmosphere is difficult to reduce to a single chemical number. Burning materials produce gases and aerosols, while heat and reduced visibility can independently prevent escape.[5] The concentrations depend on the materials burning, ventilation, burning mode and distance from the fire.[5] The handbook therefore treats smoke toxicity as an exposure scenario rather than a fixed property of one product.[5] It also says unknown types and quantities of combustion products prevent substance-by-substance respirator selection during structural firefighting.[4]
Carbon monoxide illustrates why time matters. The handbook describes its effects as depending on accumulated inhaled dose and on factors that change breathing rate.[8][17] A brief measurement does not by itself show a person's total exposure.[8][11] Irritant gases are different: immediate eye and upper-airway effects depend mainly on current concentration, while serious pulmonary effects can follow high exposures after a delay of 6 to 48 hours.[10] These mechanisms are reasons to keep the toxicant and endpoint attached to any quoted limit.[8][10]
Oxygen depletion is a separate atmospheric danger. The handbook reports that oxygen near 17% may impair motor coordination; in the 14–10% range, judgment and stamina may suffer; and at 10–6%, unconsciousness can occur.[17] These are descriptions of human effects, not substance-specific IDLH concentrations.[17][2] Exertion can bring oxygen-deficiency symptoms at higher oxygen fractions.[17] The 2008 respirator chapter accordingly names oxygen-deficient conditions separately from IDLH atmospheres.[2]
An exception reported in that edition shows why the classification must retain its time and setting. Teele describes contemporary wildland practice as not classifying wildfire smoke as IDLH, while saying its short- and long-term health effects had not been quantified.[18] The chapter also warns that a particulate filter does nothing to protect against carbon monoxide.[18] That historical practice statement cannot be read as proof that a particular wildfire atmosphere is harmless.[18]
Worked comparison: hydrogen chloride
Hydrogen chloride provides a documented example of how different acute criteria can be confused. In Purser's 2002 SFPE table, 200 ppm is predicted to impair escape in half a population, while 900 ppm is predicted to cause incapacitation in half.[12] In the 2008 handbook's account of ISO 13571, the estimated incapacitating concentration is 1,000 µL/L.[10] A microlitre per litre is numerically one part per million by volume, so the handbook's number is 1,000 ppm on the same concentration scale.[8] The two sources use different methods and should retain their separate labels.[12][10]
The SFPE incapacitation estimate divided by its escape-impairment estimate is 900/200 = 4.5. Dividing the handbook estimate by the SFPE escape-impairment estimate gives 1,000/200 = 5.[12][10] These ratios are simple comparisons of reported endpoints, not safety factors or an IDLH calculation. Purser also discusses one-hour Emergency Response Planning Guidelines for hydrogen chloride: 20 ppm for protection against serious effects impairing action and 100 ppm for protection against life-threatening effects.[12][19] Their exposure period and protective aims differ from the fire-escape estimates.[12][19]
The 30-minute rat LC50 of 3,800 µL/L in the handbook has still another population and endpoint.[9] None of the values in this example is presented as a hydrogen-chloride IDLH value on the pages cited here.[10][9][12] The comparison shows why a number cannot be moved between a worksheet's “IDLH”, “LC50”, workplace and escape-impairment columns merely because they share a gas and a concentration unit.[7][12]
Limits of a single value
The IDLH concept signals severe acute atmospheric danger, but its use still depends on identifying the relevant chemical and measuring or predicting exposure.[1][3] The handbook's incident model explicitly considers the form and rate of release, weather, terrain and changing concentrations.[6][3] Its fire chapter adds that multiple gases, heat and smoke obscuration may act together.[5] The boundary of a hazardous area therefore cannot be inferred from one isolated chemical threshold without the incident conditions.[3][5]
Uncertainty also surrounds the comparison values used for fire escape. Purser notes that the human experiments needed to verify severe-irritation limits cannot be performed; the estimates apply at an occupant's breathing zone, not at the fire source.[12] The handbook's 30-minute rat LC50 table and equation even print slightly different hydrogen-chloride values, 3,800 and 3,700 µL/L, on the same page.[9] Reporting the endpoint and the source is therefore more informative than quoting an unqualified concentration.[12][9]
The cited handbook and SFPE chapters do not include a substance-by-substance IDLH table or current text of the respiratory-protection rules. They support the definition, the 2008 response procedure and the distinctions among limits, but not a present-day IDLH value for a named chemical.[1][15][4] Any numerical value used for such a decision would need its own identified source, substance, units and conditions.[13][3]
See also
- Ammonia refrigeration
- Chemical protective clothing
- Chlorine
- Gas detection system
- National Institute for Occupational Safety and Health
Notes
- ↑ 1.00 1.01 1.02 1.03 1.04 1.05 1.06 1.07 1.08 1.09 Loflin (2008), p. 12-110.
- ↑ 2.0 2.1 2.2 2.3 2.4 2.5 2.6 2.7 2.8 Teele (2008), p. 12-150.
- ↑ 3.00 3.01 3.02 3.03 3.04 3.05 3.06 3.07 3.08 3.09 3.10 3.11 3.12 3.13 3.14 3.15 3.16 3.17 3.18 3.19 3.20 3.21 3.22 3.23 3.24 3.25 C. J. Wright (2008a), p. 13-134.
- ↑ 4.00 4.01 4.02 4.03 4.04 4.05 4.06 4.07 4.08 4.09 4.10 4.11 Teele (2008), p. 12-151.
- ↑ 5.0 5.1 5.2 5.3 5.4 5.5 5.6 5.7 Gann and Bryner (2008), p. 6-11.
- ↑ 6.0 6.1 6.2 6.3 6.4 C. J. Wright (2008a), p. 13-132.
- ↑ 7.0 7.1 7.2 7.3 7.4 C. J. Wright (2008a), p. 13-129.
- ↑ 8.0 8.1 8.2 8.3 8.4 8.5 Gann and Bryner (2008), p. 6-14.
- ↑ 9.00 9.01 9.02 9.03 9.04 9.05 9.06 9.07 9.08 9.09 Gann and Bryner (2008), p. 6-18.
- ↑ 10.0 10.1 10.2 10.3 10.4 10.5 10.6 Gann and Bryner (2008), p. 6-16.
- ↑ 11.0 11.1 Gann and Bryner (2008), p. 6-24.
- ↑ 12.00 12.01 12.02 12.03 12.04 12.05 12.06 12.07 12.08 12.09 Purser (2002), p. 2-121.
- ↑ 13.0 13.1 13.2 C. J. Wright (2008a), p. 13-127.
- ↑ C. J. Wright (2008a), p. 13-130.
- ↑ 15.0 15.1 C. J. Wright (2008a), p. 13-131.
- ↑ 16.0 16.1 16.2 16.3 Loflin (2008), p. 12-114.
- ↑ 17.0 17.1 17.2 17.3 Gann and Bryner (2008), p. 6-15.
- ↑ 18.0 18.1 18.2 Teele (2008), p. 12-154.
- ↑ 19.0 19.1 Purser (2002), p. 2-122.
References
- Gann, R. G., & Bryner, N. P. (2008). Combustion products and their effects on life safety. In A. E. Cote, C. C. Grant, J. R. Hall Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 6-11–6-34). National Fire Protection Association.
- Loflin, M. E. (2008). Safety, medical, and health issues and programs. In A. E. Cote, C. C. Grant, J. R. Hall Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 12-107–12-125). National Fire Protection Association.
- Purser, D. A. (2002). Toxicity assessment of combustion products. In P. J. DiNenno, D. Drysdale, C. L. Beyler, W. D. Walton, R. L. P. Custer, J. R. Hall Jr., & J. M. Watts Jr. (Eds.), SFPE handbook of fire protection engineering (3rd ed., pp. 2-83–2-171). National Fire Protection Association; Society of Fire Protection Engineers.
- Teele, B. W. (2008). Fire and emergency services protective clothing and protective equipment. In A. E. Cote, C. C. Grant, J. R. Hall Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 12-143–12-160). National Fire Protection Association.
- Wright, C. J. (2008a). Managing the response to hazardous material incidents. In A. E. Cote, C. C. Grant, J. R. Hall Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 13-117–13-144). National Fire Protection Association.