Skip to content
From Fire Safety Academy Wiki
Peter (talk | contribs)
Add SVG figures fse-fire-hose-v1.svg, fse-fire-hose-v2.svg, fse-fire-hose-v3.svg (list-4 visual plan)
Mark (talk | contribs)
m Remove source references from image captions
Line 1: Line 1:
'''Fire hose''' is a flexible conduit used to convey water or an appropriate water-based extinguishing medium between a supply and a discharge point. Its function includes both supplying [[Firefighting|firefighting]] operations and carrying the flow used for attack. The Fire Protection Handbook distinguishes attack hose, larger supply hose, occupant-use hose and forestry hose because their duties differ.<ref name="F-3e9f9bbde6">Cote et al. (2008), chapter 12.16, pp. 12-285.</ref>
'''Fire hose''' is a flexible conduit used to convey water or an appropriate water-based extinguishing medium between a supply and a discharge point. Its function includes both supplying [[Firefighting|firefighting]] operations and carrying the flow used for attack. The Fire Protection Handbook distinguishes attack hose, larger supply hose, occupant-use hose and forestry hose because their duties differ.<ref name="F-3e9f9bbde6">Cote et al. (2008), chapter 12.16, pp. 12-285.</ref>
[[File:fse-fire-hose-v1.svg|thumb|upright=1.5|alt=Show the components of the pressure balance.|Show the components of the pressure balance. Based on Cote et al. (2008), chapter 12.16, pp. 12-285; Cote et al. (2008), chapter 12.16, pp. 12-274–12-275, 12-285–12-286; Cote et al. (2008), chapter 13.3, pp. 13-29.]]
[[File:fse-fire-hose-v1.svg|thumb|upright=1.5|alt=Show the components of the pressure balance.|Show the components of the pressure balance.]]


The hose connects equipment such as [[Fire apparatus|fire apparatus]], a [[Fire nozzle|fire nozzle]] and building outlets supplied by [[Dry and wet risers|dry and wet risers]]. A [[Hose reel|hose reel]] is a particular storage and use arrangement, rather than a synonym for every fire hose. Coupling compatibility, condition and routing affect whether the intended water path can be established.<ref name="F-562905d52c">Cote et al. (2008), chapter 12.16, pp. 12-274–12-275, 12-285–12-286.</ref>
The hose connects equipment such as [[Fire apparatus|fire apparatus]], a [[Fire nozzle|fire nozzle]] and building outlets supplied by [[Dry and wet risers|dry and wet risers]]. A [[Hose reel|hose reel]] is a particular storage and use arrangement, rather than a synonym for every fire hose. Coupling compatibility, condition and routing affect whether the intended water path can be established.<ref name="F-562905d52c">Cote et al. (2008), chapter 12.16, pp. 12-274–12-275, 12-285–12-286.</ref>
Line 30: Line 30:
== Heat absorption and delivery to the fuel ==
== Heat absorption and delivery to the fuel ==
Water absorbs energy as its temperature increases and as liquid changes into vapour. This gives it substantial cooling capacity, but that capacity is useful only where heat transfer actually occurs. Water passing through a fire without sufficient heating does not realise its full theoretical capacity. A heat-balance calculation therefore describes a potential contribution rather than an automatic prediction of extinguishment.<ref name="F-a7e389f0f3">Cote et al. (2008), chapter 17.3, pp. 17-32–17-33.</ref>
Water absorbs energy as its temperature increases and as liquid changes into vapour. This gives it substantial cooling capacity, but that capacity is useful only where heat transfer actually occurs. Water passing through a fire without sufficient heating does not realise its full theoretical capacity. A heat-balance calculation therefore describes a potential contribution rather than an automatic prediction of extinguishment.<ref name="F-a7e389f0f3">Cote et al. (2008), chapter 17.3, pp. 17-32–17-33.</ref>
[[File:fse-fire-hose-v2.svg|thumb|upright=1.5|alt=Explain the mechanism supporting fire hose.|Explain the mechanism supporting fire hose. Based on Cote et al. (2008), chapter 17.3, pp. 17-32–17-33; Cote et al. (2008), chapter 17.3, pp. 17-33.]]
[[File:fse-fire-hose-v2.svg|thumb|upright=1.5|alt=Explain the mechanism supporting fire hose.|Explain the mechanism supporting fire hose.]]


For ordinary solid fuels, cooling the burning surface can reduce the generation of combustible vapour. Water can also cool the surrounding gases and reduce heat transferred back to the fuel. The relative importance of these effects depends on the fire and the application method. The handbook distinguishes direct fuel cooling from the effects of droplets and steam within the surrounding hot environment.<ref name="F-a7e389f0f3" />
For ordinary solid fuels, cooling the burning surface can reduce the generation of combustible vapour. Water can also cool the surrounding gases and reduce heat transferred back to the fuel. The relative importance of these effects depends on the fire and the application method. The handbook distinguishes direct fuel cooling from the effects of droplets and steam within the surrounding hot environment.<ref name="F-a7e389f0f3" />
Line 85: Line 85:
== Commissioning, maintenance and change ==
== Commissioning, maintenance and change ==
An installed system needs evidence that its components perform the intended sequence together. Commissioning examines the arrangement as built, including supplies, controls and the interfaces with the protected process. A component test establishes only the behaviour observed under that test. The Australian part of the International Fire Engineering Guidelines treats commissioning as a distinct stage connecting design and subsequent occupation or use.<ref name="I-f73f312240">National Research Council of Canada et al. (2005), §0.3.2.4–0.3.2.6; pp. 0.3-6–0.3-7.</ref>
An installed system needs evidence that its components perform the intended sequence together. Commissioning examines the arrangement as built, including supplies, controls and the interfaces with the protected process. A component test establishes only the behaviour observed under that test. The Australian part of the International Fire Engineering Guidelines treats commissioning as a distinct stage connecting design and subsequent occupation or use.<ref name="I-f73f312240">National Research Council of Canada et al. (2005), §0.3.2.4–0.3.2.6; pp. 0.3-6–0.3-7.</ref>
[[File:fse-fire-hose-v3.svg|thumb|upright=1.5|alt=Distinguish complementary evidence needed to assess fire hose.|Distinguish complementary evidence needed to assess fire hose. Based on National Research Council of Canada et al. (2005), §0.3.2.4–0.3.2.6; pp. 0.3-6–0.3-7; Cote et al. (2008), chapter 17.4, pp. 17-68; Cote et al. (2008), chapter 17.5, pp. 17-89–17-91.]]
[[File:fse-fire-hose-v3.svg|thumb|upright=1.5|alt=Distinguish complementary evidence needed to assess fire hose.|Distinguish complementary evidence needed to assess fire hose.]]


Inspection and functional testing provide complementary information. Physical examination can reveal corrosion, obstruction, leakage or changes around the hazard. Functional tests can demonstrate flow, proportioning, signalling or mechanical movement under specified conditions. The Fire Protection Handbook's foam-system discussion separates these checks from the more extensive task of demonstrating complete extinguishing performance. It also recognises test arrangements that avoid unnecessarily discharging agent over the protected equipment.<ref name="F-2ef4d8b6a4">Cote et al. (2008), chapter 17.4, pp. 17-68.</ref>
Inspection and functional testing provide complementary information. Physical examination can reveal corrosion, obstruction, leakage or changes around the hazard. Functional tests can demonstrate flow, proportioning, signalling or mechanical movement under specified conditions. The Fire Protection Handbook's foam-system discussion separates these checks from the more extensive task of demonstrating complete extinguishing performance. It also recognises test arrangements that avoid unnecessarily discharging agent over the protected equipment.<ref name="F-2ef4d8b6a4">Cote et al. (2008), chapter 17.4, pp. 17-68.</ref>

Revision as of 08:27, 13 November 2026

Fire hose is a flexible conduit used to convey water or an appropriate water-based extinguishing medium between a supply and a discharge point. Its function includes both supplying firefighting operations and carrying the flow used for attack. The Fire Protection Handbook distinguishes attack hose, larger supply hose, occupant-use hose and forestry hose because their duties differ.[1]

Show the components of the pressure balance.
Show the components of the pressure balance.

The hose connects equipment such as fire apparatus, a fire nozzle and building outlets supplied by dry and wet risers. A hose reel is a particular storage and use arrangement, rather than a synonym for every fire hose. Coupling compatibility, condition and routing affect whether the intended water path can be established.[2]

Flow through the hose creates friction loss, while a change in elevation changes the pressure needed at the supply. Hose selection therefore involves hydraulic performance as well as handling and durability. An apparently intact hose is only one component of the complete delivery arrangement.[3]

Discharge characteristics and calculation

The hydraulic calculation follows the path from the pump to the nozzle. Pump discharge pressure must cover nozzle pressure, losses along the route and the effect of elevation. For water, the handbook gives an elevation contribution of approximately 9.81 kPa per metre. The sign is positive when the nozzle is above the pump and negative when it is below.[3]

The pressure balance can be written as follows, with elevation measured relative to the pump: ppump=pnozzle+Δploss+9.81h.[3]

Symbol Description Unit
ppump Pump discharge pressure kPa
pnozzle Required nozzle pressure kPa
Δploss Pressure losses along the delivery route kPa
h Nozzle elevation above the pump m

For an illustrative arrangement, take a nozzle pressure of 345 kPa, the handbook's example operating pressure for a hand-held smooth-bore nozzle. Assume a nozzle elevation of 10 m and a measured route loss of 100 kPa. The required pump pressure is then 345 + 100 + 9.81 × 10 = 543.1 kPa, or 0.55 MPa when rounded upwards to two significant figures. The elevation and loss are stated example inputs, not universal allowances.[4]

The equation describes an established flowing condition with a known route loss. It does not predict pressure surges or determine the loss without additional information. The handbook separately identifies abrupt flow changes as a source of damaging surges. Hose condition, pressure limits and the actual nozzle characteristic remain necessary parts of the assessment.[1][3]

Heat absorption and delivery to the fuel

Water absorbs energy as its temperature increases and as liquid changes into vapour. This gives it substantial cooling capacity, but that capacity is useful only where heat transfer actually occurs. Water passing through a fire without sufficient heating does not realise its full theoretical capacity. A heat-balance calculation therefore describes a potential contribution rather than an automatic prediction of extinguishment.[5]

Explain the mechanism supporting fire hose.
Explain the mechanism supporting fire hose.

For ordinary solid fuels, cooling the burning surface can reduce the generation of combustible vapour. Water can also cool the surrounding gases and reduce heat transferred back to the fuel. The relative importance of these effects depends on the fire and the application method. The handbook distinguishes direct fuel cooling from the effects of droplets and steam within the surrounding hot environment.[5]

Droplet size creates a trade-off between heat transfer and penetration. Fine droplets provide more surface area for a given water volume and can exchange heat rapidly. They can also evaporate or be carried away before reaching a hot surface. Larger droplets or more coherent streams can penetrate more effectively, while presenting less surface area for heat transfer. The favourable balance therefore changes with plume strength, distance and the intended target.[6]

The amount discharged from a nozzle is consequently different from the amount delivered to the burning material. Obstructions, upward gas motion and evaporation can reduce useful delivery. The handbook uses the distinction between actual delivered density and required delivered density when discussing suppression research. For a manual stream, the same physical distinction explains why an adequate pump flow alone cannot establish that the required cooling reaches the fire.[6]

Stream form, reach and application

A solid stream and a spray distribute the same medium in different ways. A smooth-bore nozzle forms a comparatively coherent jet, while a spray nozzle breaks the flow into droplets. The coherent stream can provide reach and penetration, including resistance to wind effects. A spray provides greater exposed surface area for heat transfer, but its smaller droplets interact more strongly with surrounding air.[7]

These differences connect nozzle choice with the extinguishing objective. Cooling a solid fuel surface requires water to arrive at that surface. Cooling a hot gas region depends on contact between droplets and gases. The handbook describes both effects and the need to balance them. A particular stream shape therefore cannot be judged independently of the fire location, the route to the target and the available water supply.[5]

A visually impressive stream can conceal inadequate flow. Automatic spray nozzles can alter their discharge opening to maintain approximately constant nozzle pressure over their operating range. The resulting appearance does not prove that the flow is sufficient for the fire. The handbook explicitly distinguishes acceptable pressure and pattern from adequate water delivery. Flow, pressure and nozzle behaviour need to be interpreted together.[8]

Foam application introduces additional constraints. A coherent foam blanket can be damaged by plunging into fuel or by a disruptive water stream. Wind and fire-driven air movement can also prevent discharged foam from reaching the intended surface. The handbook consequently treats application method as part of foam performance. The discharge device, agent and target geometry form a combined delivery problem, rather than independent selections.[9]

Flow, pressure and supply

Pressure and flow describe different properties of a water supply. Pressure is force per unit area, while flow is the volume passing a point per unit time. A closed outlet can have pressure without delivering water. Once an outlet opens, the available flow depends on the supply and the resistance of the connected path. The SFPE hydraulics chapter treats these quantities within the behaviour of water in conduits.[10]

The pump must provide the pressure required at the nozzle together with the losses between pump and nozzle. Friction depends on the hose or pipe, its length and diameter, the flow and restrictions along the route. Elevation adds a further pressure requirement when water rises and provides a contribution when it descends. The Fire Protection Handbook expresses this as nozzle pressure plus friction loss, adjusted for elevation.[3]

A nozzle's flow characteristic connects pressure with discharge. A smooth-bore opening can be described by its diameter and pressure, whereas adjustable spray nozzles also depend on their particular control mechanism. Manufacturer flow data therefore serve a different purpose from a generic hose calculation. A complete assessment connects the nozzle characteristic with the available supply and the losses along the actual arrangement.[11]

Measurements also have limits. The SFPE discussion notes that a pressure gauge can be damaged by impact or pressure surges, and a field reading cannot automatically be assumed correct. A pressure measured at the pump is also not the pressure at a distant nozzle. The location, condition and operating state of the measurement belong with the recorded value when assessing water delivery.[12][3]

Equipment condition and operational dependencies

The water-delivery path includes more than the nozzle. Hose, couplings, valves, adapters and the pumping apparatus must provide a compatible route from the source to the discharge point. The handbook identifies connection compatibility as particularly relevant during mutual assistance between fire services. Additional adapters can complicate an otherwise straightforward arrangement, while unsuitable connections can prevent the intended supply from being established.[13]

Hose is exposed to mechanical and thermal damage during use. Abrasion, sharp objects, hot surfaces and pressure surges can affect its condition. Routing also influences whether the hose can remain available as operations develop. Inspection and records address this continuing service history. The handbook treats hose condition and maintenance as contributors to reliability, rather than assuming that a previously functioning length remains satisfactory indefinitely.[1]

The apparatus arrangement affects access to equipment and the speed of establishing a supply. Preconnected hose can shorten preparation, while larger supply hose supports water delivery over a route with different handling demands. An onboard tank provides an initial supply with a finite volume. The subsequent supply arrangement therefore remains part of the intended operation even when the first stream can begin from stored water.[14]

The suppression objective finally depends on coordinated use of the complete path. Changing a nozzle setting, adding hose or moving to a different elevation can alter the hydraulic demand. The flow required at the fire must be connected to the available supply under those conditions. This is why the handbook discusses nozzle pressure, friction and elevation together, and why a nominal apparatus or nozzle capacity is only part of the assessment.[11]

Matching the agent to the hazard

The first selection question concerns the material that is burning. Ordinary solid combustibles, flammable liquids, cooking fats and combustible metals do not respond identically to the same agent. The Fire Protection Handbook consequently relates extinguisher selection to fire classification and to the specific hazard within that classification. A familiar agent name is not sufficient evidence of suitability for every material in a broad group.[15]

Electrical equipment adds another selection question. Conductivity concerns the possibility of an electrical path through the applied agent, while residue concerns contamination after discharge. These characteristics are distinct from extinguishing effectiveness. An agent can be electrically non-conductive yet leave deposits that are undesirable around sensitive equipment. Conversely, a water-based formulation does not become electrically non-conductive merely because an additive improves its wetting or foaming behaviour.[16][17]

The physical arrangement of the fire also matters. A surface flame, a concealed hot mass and a continuing release of burning liquid present different delivery and re-ignition problems. Rapid flame removal does not necessarily cool the underlying material sufficiently. Protection of a process can therefore include isolation of its fuel or heat source as well as application of the selected extinguishing medium.[18][19]

Compatibility extends to the equipment carrying the agent. Concentrate, powder formulation, seals, valves and discharge devices form a specified combination. The handbook identifies both incompatible dry chemicals and foam systems requiring matched proportioning and discharge equipment. Substitution based only on a similar generic description can change flow or extinguishing performance. The applicable product information and test evidence describe the combination being assessed.[16][20]

Protection objectives and limits of performance

Suppression describes an intended change in a fire, but the required outcome needs further definition. Control can limit growth or reduce the rate of heat release without extinguishing every burning item. Extinguishment removes the continuing combustion under the conditions considered. Prevention of renewed burning may require cooling, continued agent retention or removal of an ignition source. These outcomes impose different demands on the protection arrangement.[5][21]

Agent selection follows the fuel and the objective. Water can cool a solid surface, foam can maintain a barrier over a liquid, and a gaseous agent can change the atmosphere surrounding a fire. None of these descriptions establishes universal effectiveness. The protected material, fire geometry, ventilation and available delivery arrangement determine whether the relevant mechanism can operate where it is needed.[22][23]

The assessment also distinguishes successful operation from unsuccessful or delayed operation. An explicit example appears in Australia's Fire Safety Verification Method Standard, 2022 edition. Its structural-stability scenario considers failures of suppression, delayed fire brigade intervention and combinations of failures. That requirement belongs to the Australian method and its stated scenario. It illustrates why the mere presence of equipment is insufficient evidence of the building's performance.[24]

The protection claim consequently includes its conditions of use. These include the hazard, the quantity and distribution of agent, the expected activation sequence and the time for which protection is maintained. Changes to storage, ventilation or operating procedures can alter those conditions. The International Fire Engineering Guidelines connect continued building use and alterations with review of the original engineering assumptions.[25]

Commissioning, maintenance and change

An installed system needs evidence that its components perform the intended sequence together. Commissioning examines the arrangement as built, including supplies, controls and the interfaces with the protected process. A component test establishes only the behaviour observed under that test. The Australian part of the International Fire Engineering Guidelines treats commissioning as a distinct stage connecting design and subsequent occupation or use.[26]

Distinguish complementary evidence needed to assess fire hose.
Distinguish complementary evidence needed to assess fire hose.

Inspection and functional testing provide complementary information. Physical examination can reveal corrosion, obstruction, leakage or changes around the hazard. Functional tests can demonstrate flow, proportioning, signalling or mechanical movement under specified conditions. The Fire Protection Handbook's foam-system discussion separates these checks from the more extensive task of demonstrating complete extinguishing performance. It also recognises test arrangements that avoid unnecessarily discharging agent over the protected equipment.[27]

Records connect observations with the installation's intended performance. An indicated pressure, for example, establishes a different fact from a measured agent quantity or a demonstrated discharge pattern. The handbook makes this distinction particularly clear for portable extinguishers. A satisfactory observation must therefore be interpreted in relation to what was measured, rather than treated as proof that every possible failure has been excluded.[28]

Continuing performance also depends on management of change. A modified appliance, altered storage arrangement or new partition may change the hazard while leaving the protection equipment apparently intact. Maintenance alone cannot restore a design assumption that no longer describes the site. The IFEG lifecycle approach consequently connects alterations, operational responsibilities and maintenance with the original fire engineering assessment and its documented conditions.[25]

See also

Notes

  1. ↑ 1.0 1.1 1.2 Cote et al. (2008), chapter 12.16, pp. 12-285.
  2. ↑ Cote et al. (2008), chapter 12.16, pp. 12-274–12-275, 12-285–12-286.
  3. ↑ 3.0 3.1 3.2 3.3 3.4 3.5 Cote et al. (2008), chapter 13.3, pp. 13-29.
  4. ↑ Cote et al. (2008), chapter 13.3, pp. 13-27, 13-29.
  5. ↑ 5.0 5.1 5.2 5.3 Cote et al. (2008), chapter 17.3, pp. 17-32–17-33.
  6. ↑ 6.0 6.1 Cote et al. (2008), chapter 17.3, pp. 17-33.
  7. ↑ Cote et al. (2008), chapter 13.3, pp. 13-27–13-28.
  8. ↑ Cote et al. (2008), chapter 13.3, pp. 13-28.
  9. ↑ Cote et al. (2008), chapter 17.4, pp. 17-46, 17-49, 17-59–17-61.
  10. ↑ Titus (2002), pp. 4-44–4-46.
  11. ↑ 11.0 11.1 Cote et al. (2008), chapter 13.3, pp. 13-27–13-29.
  12. ↑ Titus (2002), pp. 4-46.
  13. ↑ Cote et al. (2008), chapter 12.16, pp. 12-285–12-286.
  14. ↑ Cote et al. (2008), chapter 12.16, pp. 12-274–12-275.
  15. ↑ Cote et al. (2008), chapter 17.5, pp. 17-71–17-74, 17-81–17-82.
  16. ↑ 16.0 16.1 Cote et al. (2008), chapter 17.2, pp. 17-18–17-20.
  17. ↑ Cote et al. (2008), chapter 17.3, pp. 17-36–17-38.
  18. ↑ Cote et al. (2008), chapter 17.1, pp. 17-5–17-8.
  19. ↑ Cote et al. (2008), chapter 17.2, pp. 17-24–17-26.
  20. ↑ Cote et al. (2008), chapter 17.4, pp. 17-50–17-52, 17-64.
  21. ↑ Cote et al. (2008), chapter 17.6, pp. 17-119–17-121.
  22. ↑ Cote et al. (2008), chapter 17.3, pp. 17-32–17-33, 17-36–17-38.
  23. ↑ Cote et al. (2008), chapter 17.4, pp. 17-45–17-49.
  24. ↑ Australian Building Codes Board (2022), §2.12.2; p. 19.
  25. ↑ 25.0 25.1 National Research Council of Canada et al. (2005), §0.3.2.6–0.3.2.8; pp. 0.3-6–0.3-7.
  26. ↑ National Research Council of Canada et al. (2005), §0.3.2.4–0.3.2.6; pp. 0.3-6–0.3-7.
  27. ↑ Cote et al. (2008), chapter 17.4, pp. 17-68.
  28. ↑ Cote et al. (2008), chapter 17.5, pp. 17-89–17-91.

References

  • Australian Building Codes Board. (2022). Fire Safety Verification Method Standard 2022.
  • Cote, A. E., Grant, C. C., Hall, J. R., Jr., & Solomon, R. E. (Eds.). (2008). Fire Protection Handbook (20th ed.). National Fire Protection Association.
  • National Research Council of Canada, International Code Council, Department of Building and Housing, & Australian Building Codes Board. (2005). International Fire Engineering Guidelines (2005 ed.). Australian Building Codes Board.
  • Titus, J. J. (2002). Hydraulics. In P. J. DiNenno, D. Drysdale, C. L. Beyler, W. D. Walton, R. L. P. Custer, J. R. Hall, Jr., & J. M. Watts, Jr. (Eds.), SFPE Handbook of Fire Protection Engineering (3rd ed., chapter 4-2, pp. 4-44–4-71). National Fire Protection Association.