Removing fuel from the path of the fire is a common method. Crews build a line from which all flammable material has been removed, so that the fire burns until its fuel is consumed but cannot spread further.<ref name="Smalley-13-58" /> A slow fire in sparse ground fuel may be checked by one fireline dug down to mineral soil, which is soil with little humus or organic matter. A hot or fast-running fire may need more work, such as felling snags, clearing thickets and removing low limbs to prevent a crown fire.<ref name="Smalley-13-58" />
Removing fuel from the path of the fire is a common method. Crews build a line from which all flammable material has been removed, so that the fire burns until its fuel is consumed but cannot spread further.<ref name="Smalley-13-58" /> A slow fire in sparse ground fuel may be checked by one fireline dug down to mineral soil, which is soil with little humus or organic matter. A hot or fast-running fire may need more work, such as felling snags, clearing thickets and removing low limbs to prevent a crown fire.<ref name="Smalley-13-58" />
[[File:fse-wildland-fire-suppression-v1.svg|thumb|upright=1.5|alt=Fire triangle with fuel, heat and oxygen legs, each labelled with the wildland suppression method that attacks it|The three legs of the fire triangle and the wildland suppression method that attacks each. Based on Smalley (2008), pp. 13-57–13-58.]]
[[File:fse-wildland-fire-suppression-v1.svg|thumb|upright=1.5|alt=Fire triangle with fuel, heat and oxygen legs, each labelled with the wildland suppression method that attacks it|The three legs of the fire triangle and the wildland suppression method that attacks each.]]


Water lowers the fuel temperature below the ignition point, and it must be aimed at the burning fuel rather than at the flames.<ref name="Smalley-13-58" /> Much of the water played on flames misses the fuel or evaporates, while the hot fuel keeps releasing flammable gases. Where the flames are too fierce to approach, a fog nozzle first knocks them down, after which the heated fuels are cooled thoroughly.<ref name="Smalley-13-58" />
Water lowers the fuel temperature below the ignition point, and it must be aimed at the burning fuel rather than at the flames.<ref name="Smalley-13-58" /> Much of the water played on flames misses the fuel or evaporates, while the hot fuel keeps releasing flammable gases. Where the flames are too fierce to approach, a fog nozzle first knocks them down, after which the heated fuels are cooled thoroughly.<ref name="Smalley-13-58" />
Line 62: Line 62:


As a worked example, take a fire in a uniform fuel bed. The empirical correlation uses the numerical wind speed in m/s: <math>(1 + V_\infty)</math> is 1 in calm air and 6 at 5 m/s. It gives a sixfold spread-rate ratio for the same fuel bed, not a field prediction.<ref name="Quintiere-2-255" /> If the wind stretches the fire into an ellipse with an assumed length-to-breadth ratio of 3, the head-to-back ratio is <math>(3 + \sqrt{8})/(3 - \sqrt{8}) \approx 34</math>. The rear then advances at about 3 percent of the head-fire rate and each flank at about 17 percent.<ref name="McGrattan-135-136" /> The handbook's attack rules likewise treat the head as the most dangerous part: crews size up a fast fire from a vantage point or its flanks, never by going around its head.<ref name="Smalley-13-70" />
As a worked example, take a fire in a uniform fuel bed. The empirical correlation uses the numerical wind speed in m/s: <math>(1 + V_\infty)</math> is 1 in calm air and 6 at 5 m/s. It gives a sixfold spread-rate ratio for the same fuel bed, not a field prediction.<ref name="Quintiere-2-255" /> If the wind stretches the fire into an ellipse with an assumed length-to-breadth ratio of 3, the head-to-back ratio is <math>(3 + \sqrt{8})/(3 - \sqrt{8}) \approx 34</math>. The rear then advances at about 3 percent of the head-fire rate and each flank at about 17 percent.<ref name="McGrattan-135-136" /> The handbook's attack rules likewise treat the head as the most dangerous part: crews size up a fast fire from a vantage point or its flanks, never by going around its head.<ref name="Smalley-13-70" />
[[File:fse-wildland-fire-suppression-v2.svg|thumb|upright=1.5|alt=Three fire outlines from one ignition point: a circle for no wind or slope and ellipses for length-to-breadth ratios 2 and 3, with head, flank and rear marked|Fire outlines after equal times for length-to-breadth ratios of 1, 2 and 3, with spread rates as a share of the head-fire rate. Based on McGrattan et al. (2026), pp. 135–136.]]
[[File:fse-wildland-fire-suppression-v2.svg|thumb|upright=1.5|alt=Three fire outlines from one ignition point: a circle for no wind or slope and ellipses for length-to-breadth ratios 2 and 3, with head, flank and rear marked|Fire outlines after equal times for length-to-breadth ratios of 1, 2 and 3, with spread rates as a share of the head-fire rate.]]


Both relations are simplifications. The Thomas correlation is described as approximate, its printed symbol list calls ''V'' the concurrent wind speed, and the sources give no bulk densities for wildland fuel beds. Here it therefore shows a trend rather than an absolute rate.<ref name="Quintiere-2-255" /> The elliptical model also assumes a fixed shape for each point of the front.<ref name="McGrattan-135-136" />
Both relations are simplifications. The Thomas correlation is described as approximate, its printed symbol list calls ''V'' the concurrent wind speed, and the sources give no bulk densities for wildland fuel beds. Here it therefore shows a trend rather than an absolute rate.<ref name="Quintiere-2-255" /> The elliptical model also assumes a fixed shape for each point of the front.<ref name="McGrattan-135-136" />
Line 68: Line 68:
== Suppression sequence and fireline tactics ==
== Suppression sequence and fireline tactics ==
Wildland fire management strategies aim at prompt, safe and aggressive suppression of all wildfires, and small fires need the same practices as large ones.<ref name="Smalley-13-70" /> A small fire is suppressed in seven steps: first attack, line location, line construction, burning out, mop-up, patrol and declaring the fire out. The strategy ranges from prompt control at the smallest possible area to containment by fireline and natural barriers, or merely keeping the fire inside a defined area.<ref name="Smalley-13-70" /> The attack rules are to act promptly on an attack point, to stay with the fire and to take the most effective action possible with the forces available. Crews also report the situation by radio and keep working at night where this is safe.<ref name="Smalley-13-70-71">Smalley (2008), pp. 13-70–13-71.</ref>
Wildland fire management strategies aim at prompt, safe and aggressive suppression of all wildfires, and small fires need the same practices as large ones.<ref name="Smalley-13-70" /> A small fire is suppressed in seven steps: first attack, line location, line construction, burning out, mop-up, patrol and declaring the fire out. The strategy ranges from prompt control at the smallest possible area to containment by fireline and natural barriers, or merely keeping the fire inside a defined area.<ref name="Smalley-13-70" /> The attack rules are to act promptly on an attack point, to stay with the fire and to take the most effective action possible with the forces available. Crews also report the situation by radio and keep working at night where this is safe.<ref name="Smalley-13-70-71">Smalley (2008), pp. 13-70–13-71.</ref>
[[File:fse-wildland-fire-suppression-v3.svg|thumb|upright=1.5|alt=Flowchart of seven steps from first attack to declaring the fire out, with a marker where the fire is called controlled|The suppression sequence for a small wildland fire, from first attack to declaring the fire out. Based on Smalley (2008), pp. 13-70–13-71.]]
[[File:fse-wildland-fire-suppression-v3.svg|thumb|upright=1.5|alt=Flowchart of seven steps from first attack to declaring the fire out, with a marker where the fire is called controlled|The suppression sequence for a small wildland fire, from first attack to declaring the fire out.]]


The fireline is also called the control line. A glossary in NUREG-1805 (2004) defines controlling a fire as completing a control line around the fire, any spot fires and any interior islands to be saved. Controlling also includes burning out the unburned area on the fire side of the line and cooling hot spots that threaten it.<ref name="Iqbal-F-17">Iqbal and Salley (2004), p. F-17.</ref> Crews light burnouts and backfires with drip torches, and hotshot crews build firelines, burn out, set backfires and mop up.<ref name="Smalley-13-73">Smalley (2008), p. 13-73.</ref><ref name="Smalley-13-71">Smalley (2008), p. 13-71.</ref> Air tankers drop retardant in a long string to slow the fire, giving ground forces the opportunity to build firelines.<ref name="Smalley-13-72">Smalley (2008), p. 13-72.</ref>
The fireline is also called the control line. A glossary in NUREG-1805 (2004) defines controlling a fire as completing a control line around the fire, any spot fires and any interior islands to be saved. Controlling also includes burning out the unburned area on the fire side of the line and cooling hot spots that threaten it.<ref name="Iqbal-F-17">Iqbal and Salley (2004), p. F-17.</ref> Crews light burnouts and backfires with drip torches, and hotshot crews build firelines, burn out, set backfires and mop up.<ref name="Smalley-13-73">Smalley (2008), p. 13-73.</ref><ref name="Smalley-13-71">Smalley (2008), p. 13-71.</ref> Air tankers drop retardant in a long string to slow the fire, giving ground forces the opportunity to build firelines.<ref name="Smalley-13-72">Smalley (2008), p. 13-72.</ref>
Line 93: Line 93:


Aircraft extend the reach of the ground forces. In a typical year 15 to 20 heavy and medium helicopters were under contract in the United States, plus 175 on call.<ref name="Smalley-13-72" /> Single engine air tankers, which are modified crop dusters, drop 1893 to 3028 L (500 to 800 gal) of retardant on small fires. Large air tankers carry 7571 to 11,356 L (2000 to 3000 gal), and 40 to 50 were under contract in a typical year.<ref name="Smalley-13-72" /> Infrared aircraft can pinpoint a 15 cm hot spot from 2.4 km above the ground, usually flying at night when the temperature contrast is largest.<ref name="Smalley-13-72-73">Smalley (2008), pp. 13-72–13-73.</ref> About 1150 remote automated weather stations in the United States report weather and fuel moisture every hour by satellite.<ref name="Smalley-13-73" />
Aircraft extend the reach of the ground forces. In a typical year 15 to 20 heavy and medium helicopters were under contract in the United States, plus 175 on call.<ref name="Smalley-13-72" /> Single engine air tankers, which are modified crop dusters, drop 1893 to 3028 L (500 to 800 gal) of retardant on small fires. Large air tankers carry 7571 to 11,356 L (2000 to 3000 gal), and 40 to 50 were under contract in a typical year.<ref name="Smalley-13-72" /> Infrared aircraft can pinpoint a 15 cm hot spot from 2.4 km above the ground, usually flying at night when the temperature contrast is largest.<ref name="Smalley-13-72-73">Smalley (2008), pp. 13-72–13-73.</ref> About 1150 remote automated weather stations in the United States report weather and fuel moisture every hour by satellite.<ref name="Smalley-13-73" />
[[File:fse-wildland-fire-suppression-v4.svg|thumb|upright=1.5|alt=Horizontal bar chart on a logarithmic scale of water or retardant capacity from a 19 litre backpack pump to an 11,356 litre air tanker|Water or retardant carried per unit by wildland suppression resources in the United States, logarithmic scale. Based on Smalley (2008), pp. 13-71–13-72; Tutterow (2008), p. 12-275; Conroy (2008), p. 17-77.]]
[[File:fse-wildland-fire-suppression-v4.svg|thumb|upright=1.5|alt=Horizontal bar chart on a logarithmic scale of water or retardant capacity from a 19 litre backpack pump to an 11,356 litre air tanker|Water or retardant carried per unit by wildland suppression resources in the United States, logarithmic scale.]]


Suppression in the United States rests on a three-tier system. The local agency responds first, then asks one of 11 geographic areas for help, and finally the national coordination centre in Boise, Idaho.<ref name="Smalley-13-68" /> The [[incident command system]] itself grew out of wildland fire. In 13 days of fires in southern California in 1970, 16 people died, 700 structures were destroyed and over 200,000 ha (500,000 acres) burned.<ref name="Loflin-12-119-120">Loflin (2008), pp. 12-119–12-120.</ref> The FIRESCOPE incident command system was developed in response.<ref name="Loflin-12-119-120" /> In 2005, 85 percent of US local fire departments provided wildland firefighting.<ref name="HallCote-3-27">Hall and Cote (2008), p. 3-27.</ref>
Suppression in the United States rests on a three-tier system. The local agency responds first, then asks one of 11 geographic areas for help, and finally the national coordination centre in Boise, Idaho.<ref name="Smalley-13-68" /> The [[incident command system]] itself grew out of wildland fire. In 13 days of fires in southern California in 1970, 16 people died, 700 structures were destroyed and over 200,000 ha (500,000 acres) burned.<ref name="Loflin-12-119-120">Loflin (2008), pp. 12-119–12-120.</ref> The FIRESCOPE incident command system was developed in response.<ref name="Loflin-12-119-120" /> In 2005, 85 percent of US local fire departments provided wildland firefighting.<ref name="HallCote-3-27">Hall and Cote (2008), p. 3-27.</ref>

Latest revision as of 08:39, 13 November 2026

Wildland fire suppression is all the work done to confine and extinguish a fire in natural vegetation such as grass, brush and forest, beginning with its discovery.[1][2] It is the branch of firefighting that deals with the wildfire rather than with fires inside buildings. Crews break the fire triangle by cutting a fireline down to bare mineral soil, cooling burning fuel with water and smothering fine fuels with soil.[3] In the United States, the main setting of the sources, hand crews, engines and aircraft are mobilised through a three-tier system of local, regional and national support.[4] Local agencies contain single ignitions in 98 to 99 percent of cases, but fires that escape under severe weather can overwhelm suppression forces, especially at the wildland-urban interface.[5] Wildland fires and control burns caused 15.9 percent of on-duty firefighter deaths in the United States between 1996 and 2005.[6]

Principles of extinguishment in wildland fuels

A fire needs heat, oxygen and fuel in the right proportion, a model known as the fire triangle.[7][8] Air contains about 21 percent oxygen by volume, and a fire stops spreading when the oxygen level falls far enough.[7] A wildland fire, however, burns freely in the open, so removing its oxygen supply is usually impractical.[8] The handbook therefore describes wildland suppression in terms of the three sides of the fire triangle; breaking the chemical chain reaction is not normally part of its methods.[8]

Removing fuel from the path of the fire is a common method. Crews build a line from which all flammable material has been removed, so that the fire burns until its fuel is consumed but cannot spread further.[3] A slow fire in sparse ground fuel may be checked by one fireline dug down to mineral soil, which is soil with little humus or organic matter. A hot or fast-running fire may need more work, such as felling snags, clearing thickets and removing low limbs to prevent a crown fire.[3]

Fire triangle with fuel, heat and oxygen legs, each labelled with the wildland suppression method that attacks it
The three legs of the fire triangle and the wildland suppression method that attacks each.

Water lowers the fuel temperature below the ignition point, and it must be aimed at the burning fuel rather than at the flames.[3] Much of the water played on flames misses the fuel or evaporates, while the hot fuel keeps releasing flammable gases. Where the flames are too fierce to approach, a fog nozzle first knocks them down, after which the heated fuels are cooled thoroughly.[3]

Soil thrown on burning material slows combustion by shielding part of the fuel surface, but most soils are too porous to cut off the air completely.[3] Smothering works best in fine fuels such as dry grass, which hold little heat, using gunnysacks, fire swatters or a shovel of dirt. Where dead stems and leaves lie beneath the grass, this layer can hold enough heat to reignite once air returns.[3]

Fires that look dead can reignite. The passage of a forest fire frequently leaves the duff layer, the partly decayed organic material on the forest floor, smouldering in an irregular pattern that can rekindle a flaming fire.[9] The key to stopping smouldering is removing heat from the fuel, since cutting off oxygen only works if it is kept up until the fuel has cooled.[9] For the same reason an experienced wildland firefighter feels the fuel by hand before leaving an area.[3]

Fire behaviour that governs suppression

Radiation is the main route by which heat passes from burning to unburned fuel in a forest fire. The location and width of firelines must therefore be chosen partly on the rate of radiant heat transfer.[3] Wind raises this transfer by making the fire hotter and by bending the flames towards the fuel ahead, while conduction plays a minor role.[3][10] Fires burn faster up steep slopes because the fuels above them receive more radiant and convective heat. As a rule of thumb, the rate of spread doubles on a 30 percent slope, about 17 degrees, and doubles again on a 55 percent slope, about 29 degrees.[10] In the SFPE Handbook, the jump of a forest fire across a firebreak is generally viewed as radiant ignition, and the break needed to stop a fire depends on its size and heat transfer.[11][12]

Fine deadwood, meaning twigs, small limbs and bark less than 50.8 mm (2 in.) in diameter, carries fire from one area to another and kindles heavier fuels.[13] In most forest fires the control job is aimed at fine deadwood and the duff and leaves beneath it. Final control needs a fireline down to mineral soil in nearly all cases.[13] Heavy logs need very large volumes of water or soil, so fire is sometimes left to burn out in them before mop-up.[13] Fires creeping along tree roots have escaped control lines, so roots are cut where they cross the line.[14]

The moisture of dead fuel follows that of the air with a delay called the time lag, which grows with fuel diameter.[15] The 1-hour class covers fuels under 6.35 mm (¼ in.), such as annual grass, and the 10-hour class fuels of 6.35–25.4 mm, such as chaparral. The 100-hour class covers 25.4–76.2 mm, such as logging slash, and the 1000-hour class 76.2–203 mm, such as logs and mature standing timber.[15] Heavy fuels therefore need long periods of hot, dry weather before they become highly flammable.[13]

Crown fires are extremely difficult to control. The main effort is to suppress the fire in the ground fuels and keep it out of the crowns, for example by removing limbs from the lower trunks.[16] Crown fires also throw burning embers, or firebrands, far ahead of the main fire, where they start spot fires. Spot fires become more frequent and severe as fuel moisture drops and wind increases.[15]

Estimating spread rate and fire shape

The USDA Forest Service has developed practical methods for estimating fire spread in the field, and Rothermel reviews the theory and models for fire behaviour prediction, including the BEHAVE computer model.[12] A correlation by Thomas, quoted in the SFPE Handbook, applies to wildland fires, wood cribs and urban conflagrations.[12] In words, the spread rate times the bulk density of the fuel bed equals an empirical constant times one plus the wind speed in metres per second. A denser fuel bed slows the fire, and wind speeds it up.

Vρb=k(1+V∞)

In the level set model of the Fire Dynamics Simulator (FDS), the default formulation, which follows FARSITE, lets each point of the fire front grow as an ellipse.[17] For elongated ellipses, the head advances fastest, the flanks more slowly and the rear slowest. The shape is set by the length-to-breadth ratio, which depends on a virtual wind combining actual wind and slope effects and is bounded between 1 and 8.[17] With no wind and no slope the ratio equals 1 and the fire grows as a circle. The head-to-back ratio and the ellipse parameters follow from this ratio and the head-fire rate; the flank rate equals a and the back rate b − c:[17]

HB=LB+LB2−1LB−LB2−1

b=12(R+RHB),a=bLB,c=b−RHB

By default, FDS takes the head-fire rate from the Rothermel model. Where wind and slope align with spread, R=R0(1+ϕW+ϕS); FDS treats their effects as vectors when they differ in direction.[18]

Symbol Description Unit
V rate of fire spread m/s
ρb bulk density of the fuel bed kg/m³
V∞ wind speed in the direction of spread m/s
k empirical constant: 0.07 for wildland fires, 0.05 for wood cribs kg/m³
R head-fire spread rate m/s
R0 spread rate without wind and slope m/s
ϕW,ϕS wind factor and slope factor dimensionless
LB length-to-breadth ratio of the fire ellipse (1 to 8) dimensionless
HB head-to-back spread ratio dimensionless
a flank spread rate m/s
b,c ellipse parameters; the back spread rate is b−c m/s

As a worked example, take a fire in a uniform fuel bed. The empirical correlation uses the numerical wind speed in m/s: (1+V∞) is 1 in calm air and 6 at 5 m/s. It gives a sixfold spread-rate ratio for the same fuel bed, not a field prediction.[12] If the wind stretches the fire into an ellipse with an assumed length-to-breadth ratio of 3, the head-to-back ratio is (3+8)/(3−8)≈34. The rear then advances at about 3 percent of the head-fire rate and each flank at about 17 percent.[17] The handbook's attack rules likewise treat the head as the most dangerous part: crews size up a fast fire from a vantage point or its flanks, never by going around its head.[1]

Three fire outlines from one ignition point: a circle for no wind or slope and ellipses for length-to-breadth ratios 2 and 3, with head, flank and rear marked
Fire outlines after equal times for length-to-breadth ratios of 1, 2 and 3, with spread rates as a share of the head-fire rate.

Both relations are simplifications. The Thomas correlation is described as approximate, its printed symbol list calls V the concurrent wind speed, and the sources give no bulk densities for wildland fuel beds. Here it therefore shows a trend rather than an absolute rate.[12] The elliptical model also assumes a fixed shape for each point of the front.[17]

Suppression sequence and fireline tactics

Wildland fire management strategies aim at prompt, safe and aggressive suppression of all wildfires, and small fires need the same practices as large ones.[1] A small fire is suppressed in seven steps: first attack, line location, line construction, burning out, mop-up, patrol and declaring the fire out. The strategy ranges from prompt control at the smallest possible area to containment by fireline and natural barriers, or merely keeping the fire inside a defined area.[1] The attack rules are to act promptly on an attack point, to stay with the fire and to take the most effective action possible with the forces available. Crews also report the situation by radio and keep working at night where this is safe.[19]

Flowchart of seven steps from first attack to declaring the fire out, with a marker where the fire is called controlled
The suppression sequence for a small wildland fire, from first attack to declaring the fire out.

The fireline is also called the control line. A glossary in NUREG-1805 (2004) defines controlling a fire as completing a control line around the fire, any spot fires and any interior islands to be saved. Controlling also includes burning out the unburned area on the fire side of the line and cooling hot spots that threaten it.[20] Crews light burnouts and backfires with drip torches, and hotshot crews build firelines, burn out, set backfires and mop up.[21][22] Air tankers drop retardant in a long string to slow the fire, giving ground forces the opportunity to build firelines.[23]

Hand crew with hand tools clearing a strip of vegetation down to bare soil next to a burning area
A hand crew clearing vegetation to build a fireline down to mineral soil.

Once the spread has stopped and all lines are complete, the fire is called controlled, but it is not yet out. Mop-up puts out all embers and sparks so that none can cross the fireline, either by extinguishing them or by burning or removing the remaining fuel.[22] Patrols move back and forth along the line to catch fire crossing it and spot fires outside it. Before leaving, the incident commander makes sure the fire is out and the line would hold a flare-up.[22] Duff fires inside a line are best mopped up by turning the duff over with a shovel so that it burns out.[14]

According to the 2008 handbook, nearly all wildfires in the United States are controlled at 40 ha (100 acres) or less, but roughly 2 percent of fires account for two-thirds of the burned area.[24] Early detection relies on lookouts in fire towers, aircraft patrols and, in the western United States and parts of Canada, electronic lightning detection.[1]

Water, foam and other agents

The handbook describes a typical wildland engine as an off-road vehicle carrying up to 3028 L (800 gal) of water, with a crew of three to five.[22] In the United States such vehicles fall under NFPA 1906, Standard for Wildland Fire Apparatus, which requires a pump that can work while the vehicle drives, known as pump-and-roll.[25][26] As summarised in the 2008 handbook, it requires a tank of at least 473 L (125 gal). It defines four pump ratings, from 690 kPa (100 psi) for low-pressure pumps to 2760 kPa (400 psi) for extra-high-pressure pumps.[27][26]

The 2008 handbook lists forestry hose in 25 mm (1 in.) and 38 mm (1½ in.) sizes and warns that hot spots or embers can burn it as the nozzle advances.[28] For the smallest quantities, firefighters carry backpack pump tanks, most commonly holding 19 L (5 gal) and weighing about 23 kg (50 lb) when full.[29] They are used chiefly on brush and wildland fires and for cooling hot spots during mop-up.[29][21]

Class A foam has been used extensively in wildland fire suppression, and its success on natural cover fuels suggested that it may also be effective in structural fire streams.[30] The concentrate is generally mixed with water at 0.1 to 1.0 percent, often in compressed air foam systems, which were first developed for wildland fire suppression.[31][32] For one full engine tank of 3028 L, a 0.1 percent solution needs about 3.0 L of concentrate and a 1.0 percent solution about 30 L. Wildland engines carry foam for vegetation and for protecting the outside walls of structures.[22]

Wetting agents, covered in the United States by NFPA 18, change the surface tension or viscosity of water and raise its extinguishing efficiency.[33] Plain water has a surface tension of 73 mN/m (73 dyn/cm), and wetting agents can lower it to about 25 mN/m. They work best as a soaking agent in three-dimensional burning masses such as wildland fuels.[34] Viscous water has been used mainly on forest fires: it clings to fuel and resists wind, but penetrates less well and raises friction loss.[35]

Away from hydrants, structural fire departments bring water to the scene by a water shuttle of mobile water supply apparatus, some reaching sustained flows of 3785 to 7570 L/min (1000 to 2000 gpm).[36] Inadequate water supply is listed among the watch-out situations for interface fires.[5]

Crews, aircraft and organisation

Hand crews of about 20 people cut fireline with hand tools, and the handbook counts roughly 500 such crews in the United States.[22] Hotshot crews are highly trained and experienced: the handbook lists 68 crews with 1360 firefighters in total, who take the toughest parts of a fire. Smoke jumpers parachute in as the initial attack force on remote fires, and helitack crews work from helicopters.[22][23] The Pulaski, invented by Ed Pulaski in 1910, combines an axe and a mattock, and the McLeod is a heavy rake-and-hoe for matted litter and duff.[21]

Aircraft extend the reach of the ground forces. In a typical year 15 to 20 heavy and medium helicopters were under contract in the United States, plus 175 on call.[23] Single engine air tankers, which are modified crop dusters, drop 1893 to 3028 L (500 to 800 gal) of retardant on small fires. Large air tankers carry 7571 to 11,356 L (2000 to 3000 gal), and 40 to 50 were under contract in a typical year.[23] Infrared aircraft can pinpoint a 15 cm hot spot from 2.4 km above the ground, usually flying at night when the temperature contrast is largest.[37] About 1150 remote automated weather stations in the United States report weather and fuel moisture every hour by satellite.[21]

Horizontal bar chart on a logarithmic scale of water or retardant capacity from a 19 litre backpack pump to an 11,356 litre air tanker
Water or retardant carried per unit by wildland suppression resources in the United States, logarithmic scale.

Suppression in the United States rests on a three-tier system. The local agency responds first, then asks one of 11 geographic areas for help, and finally the national coordination centre in Boise, Idaho.[4] The incident command system itself grew out of wildland fire. In 13 days of fires in southern California in 1970, 16 people died, 700 structures were destroyed and over 200,000 ha (500,000 acres) burned.[38] The FIRESCOPE incident command system was developed in response.[38] In 2005, 85 percent of US local fire departments provided wildland firefighting.[39]

Firefighter safety

Suppression is difficult and inherently dangerous work.[1] Of the 999 US firefighters who died on duty between 1996 and 2005, 159 (15.9 percent) died as a result of wildland fires or control burns. Annual totals ranged from 8 to 26, and these fires accounted for 25.5 percent of all fireground deaths.[6] Aircraft operations at major wildfires cause on-duty deaths nearly every year.[40] Wider statistics are covered under firefighter injuries and fatalities.

The Ten Standard Fire Orders were developed in 1957 by a task force studying firefighter injuries and deaths. They range from keeping informed on fire weather and identifying escape routes to fighting fire aggressively having provided for safety first.[6] Eighteen watch-out situations supplement them. Among these are constructing line without a safe anchor point, building line downhill with fire below and attempting a frontal assault on the fire.[6] Fatal and near-miss fires often occur in small or quiet parts of large fires, in light fuels such as grass, after an unexpected wind shift and when fire runs uphill.[41]

In the United States, NFPA 1500 requires protective equipment compliant with NFPA 1977 for all wildland fire-fighting operations. These exterior operations expose firefighters to radiant heat and many physical hazards, and the minimum is a fire shelter and protection for head, torso, hands and feet.[42] Respiratory protection was not yet required. Breathing apparatus is impractical for crews working long periods in remote areas because of its weight, limited use time and recharging logistics.[42][43] Air samples show potential exposure to respirable particulate, carbon monoxide, formaldehyde and acrolein, and suggested measures include short work periods and rest in smoke-free air.[43] The fire shelter is a last resort, and each deployment is recorded and investigated.[6]

Two reports to the US Congress, eight years apart, both found that over 40 percent of rural firefighters had no wildland fire training.[44] An updated US fire service needs assessment found that 63 percent of departments involved in wildland fire fighting had not formally trained all the firefighters involved.[45]

Interface fires and the limits of suppression

At the wildland-urban interface, suppression meets the built environment. NFPA 1144, as quoted in the handbook, defines the interface as structures in places where the authority having jurisdiction determines that terrain, vegetation, weather and winds could lead to their ignition by a wildland fire.[46] Under extreme conditions, firefighters, equipment and water supplies can run short as numerous homes ignite. Engines cannot evacuate residents and fight fire at the same time in a subdivision where homes ignite minutes apart.[5] Standard operations are then largely ineffective against huge flames and showering firebrands, and crews must often fall back to protect themselves.[5]

Watch-out situations specific to interface fires include narrow one-way roads, bridge load limits, wood shake roofs and inadequate water supply. They also include natural fuels within 9.1 m (30 ft) of structures and structures on slopes of 30 percent or more.[5] Because tactics differ from those for structure or forest fires alone, fire departments train jointly with forestry agencies.[5]

The handbook reports that, as debate over prescribed fire continued, suppression costs climbed and more unprotected homes were lost. This happened although agencies had treated millions of acres with prescribed fire and mechanical means; the fires in largely untreated areas were the problem.[47] A 2004 presentation by the chief of the USDA Forest Service, as summarised in the handbook, called for reducing fuels in overgrown ecosystems before large fires break out.[24] The handbook's US data to 2003 suggest fewer fires but growing burned areas, and larger fires may significantly affect suppression resources and firefighter safety.[47]

See also

Notes

  1. ↑ 1.0 1.1 1.2 1.3 1.4 1.5 Smalley (2008), p. 13-70.
  2. ↑ Iqbal and Salley (2004), p. F-29.
  3. ↑ 3.00 3.01 3.02 3.03 3.04 3.05 3.06 3.07 3.08 3.09 Smalley (2008), p. 13-58.
  4. ↑ 4.0 4.1 Smalley (2008), p. 13-68.
  5. ↑ 5.0 5.1 5.2 5.3 5.4 5.5 Smalley (2008), p. 13-66.
  6. ↑ 6.0 6.1 6.2 6.3 6.4 Smalley (2008), p. 13-74.
  7. ↑ 7.0 7.1 Van Rossum (2027), §4.2.
  8. ↑ 8.0 8.1 8.2 Smalley (2008), p. 13-57.
  9. ↑ 9.0 9.1 Ohlemiller (2002), p. 2-206.
  10. ↑ 10.0 10.1 Smalley (2008), p. 13-59.
  11. ↑ Kanury (2002a), p. 2-229.
  12. ↑ 12.0 12.1 12.2 12.3 12.4 Quintiere (2002b), p. 2-255.
  13. ↑ 13.0 13.1 13.2 13.3 Smalley (2008), p. 13-61.
  14. ↑ 14.0 14.1 Smalley (2008), p. 13-60.
  15. ↑ 15.0 15.1 15.2 Smalley (2008), p. 13-63.
  16. ↑ Smalley (2008), p. 13-62.
  17. ↑ 17.0 17.1 17.2 17.3 17.4 McGrattan et al. (2026), pp. 135–136.
  18. ↑ McGrattan et al. (2026), p. 137.
  19. ↑ Smalley (2008), pp. 13-70–13-71.
  20. ↑ Iqbal and Salley (2004), p. F-17.
  21. ↑ 21.0 21.1 21.2 21.3 Smalley (2008), p. 13-73.
  22. ↑ 22.0 22.1 22.2 22.3 22.4 22.5 22.6 Smalley (2008), p. 13-71.
  23. ↑ 23.0 23.1 23.2 23.3 Smalley (2008), p. 13-72.
  24. ↑ 24.0 24.1 Smalley (2008), p. 13-56.
  25. ↑ Tutterow (2008), p. 12-269.
  26. ↑ 26.0 26.1 Tutterow (2008), p. 12-274.
  27. ↑ Tutterow (2008), p. 12-275.
  28. ↑ Tutterow (2008), p. 12-285.
  29. ↑ 29.0 29.1 Conroy (2008), p. 17-77.
  30. ↑ Scheffey and Hickey (2002), p. 4-144.
  31. ↑ Iqbal and Salley (2004), p. B-60.
  32. ↑ Tutterow (2008), p. 12-278.
  33. ↑ Frank (2008), p. 17-36.
  34. ↑ Iqbal and Salley (2004), pp. F-70–F-71.
  35. ↑ Frank (2008), p. 17-42.
  36. ↑ Stewart (2008), p. 13-48.
  37. ↑ Smalley (2008), pp. 13-72–13-73.
  38. ↑ 38.0 38.1 Loflin (2008), pp. 12-119–12-120.
  39. ↑ Hall and Cote (2008), p. 3-27.
  40. ↑ Hall and Cote (2008), p. 3-30.
  41. ↑ Smalley (2008), pp. 13-74–13-75.
  42. ↑ 42.0 42.1 Teele (2008), p. 12-150.
  43. ↑ 43.0 43.1 Teele (2008), p. 12-154.
  44. ↑ Smalley (2008), pp. 13-73–13-74.
  45. ↑ Jenaway (2008), p. 12-42.
  46. ↑ Smalley (2008), p. 13-64.
  47. ↑ 47.0 47.1 Smalley (2008), p. 13-53.

References

  • Conroy, M. T. (2008). Fire extinguisher use and maintenance. In A. E. Cote, C. C. Grant, J. R. Hall Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 17-71–17-92). National Fire Protection Association.
  • Frank, J. A. (2008). Characteristics and hazards of water and water additives for fire suppression. In A. E. Cote, C. C. Grant, J. R. Hall Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 17-31–17-43). National Fire Protection Association.
  • Hall, J. R., Jr., & Cote, A. E. (2008). An overview of the fire problem and fire protection. In A. E. Cote, C. C. Grant, J. R. Hall Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 3-3–3-30). National Fire Protection Association.
  • Iqbal, N., & Salley, M. H. (2004). Fire Dynamics Tools (FDTs): Quantitative fire hazard analysis methods for the U.S. Nuclear Regulatory Commission Fire Protection Inspection Program (NUREG-1805). U.S. Nuclear Regulatory Commission, Office of Nuclear Reactor Regulation.
  • Jenaway, W. F. (2008). Needs assessment and hazard analysis. In A. E. Cote, C. C. Grant, J. R. Hall Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 12-41–12-50). National Fire Protection Association.
  • Kanury, A. M. (2002a). Flaming ignition of solid fuels. In P. J. DiNenno, D. Drysdale, C. L. Beyler, W. D. Walton, R. L. P. Custer, J. R. Hall Jr., & J. M. Watts Jr. (Eds.), SFPE handbook of fire protection engineering (3rd ed., pp. 2-229–2-245). National Fire Protection Association; Society of Fire Protection Engineers.
  • Loflin, M. E. (2008). Safety, medical, and health issues and programs. In A. E. Cote, C. C. Grant, J. R. Hall Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 12-107–12-125). National Fire Protection Association.
  • McGrattan, K., Hostikka, S., Floyd, J., McDermott, R., Vanella, M., Mueller, E., & Paul, C. (2026). Fire Dynamics Simulator technical reference guide: Vol. 1. Mathematical model (6th ed., NIST Special Publication 1018-1). National Institute of Standards and Technology. https://doi.org/10.6028/NIST.SP.1018
  • Ohlemiller, T. J. (2002). Smoldering combustion. In P. J. DiNenno, D. Drysdale, C. L. Beyler, W. D. Walton, R. L. P. Custer, J. R. Hall Jr., & J. M. Watts Jr. (Eds.), SFPE handbook of fire protection engineering (3rd ed., pp. 2-200–2-210). National Fire Protection Association; Society of Fire Protection Engineers.
  • Quintiere, J. G. (2002b). Surface flame spread. In P. J. DiNenno, D. Drysdale, C. L. Beyler, W. D. Walton, R. L. P. Custer, J. R. Hall Jr., & J. M. Watts Jr. (Eds.), SFPE handbook of fire protection engineering (3rd ed., pp. 2-246–2-257). National Fire Protection Association; Society of Fire Protection Engineers.
  • Scheffey, J. L., & Hickey, H. E. (2002). Foam system calculations. In P. J. DiNenno, D. Drysdale, C. L. Beyler, W. D. Walton, R. L. P. Custer, J. R. Hall Jr., & J. M. Watts Jr. (Eds.), SFPE handbook of fire protection engineering (3rd ed., pp. 4-123–4-148). National Fire Protection Association; Society of Fire Protection Engineers.
  • Smalley, J. C. (2008). Wildland fire management. In A. E. Cote, C. C. Grant, J. R. Hall Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 13-53–13-79). National Fire Protection Association.
  • Stewart, L. J. (2008). Alternate water supplies. In A. E. Cote, C. C. Grant, J. R. Hall Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 13-37–13-52). National Fire Protection Association.
  • Teele, B. W. (2008). Fire and emergency services protective clothing and protective equipment. In A. E. Cote, C. C. Grant, J. R. Hall Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 12-143–12-160). National Fire Protection Association.
  • Tutterow, R. (2008). Fire department apparatus and equipment. In A. E. Cote, C. C. Grant, J. R. Hall Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 12-267–12-287). National Fire Protection Association.
  • Van Rossum, E. (2027). Introduction to Fire Safety Engineering. Fire Safety Academy.