Decision steps for the UL 94 vertical classes.
Main criteria for the UL 94 vertical classes. Time limits are inclusive; the complete prescribed procedure also applies.
 
Source: <ref name="UL-current-vertical">UL Solutions. [https://www.ul.com/services/combustion-fire-tests-plastics Combustion (Fire) Tests for Plastics], “Test criteria for Flammability UL 94 V – 50 W, 20 mm Vertical”. Accessed 23 November 2026.</ref>


Original illustration for [[UL 94 flammability test]].
Original illustration for [[UL 94 flammability test]].


* Alt text: Flowchart: afterflame under 10 s and total under 50 s without cotton ignition gives V-0; under 30 s and 250 s gives V-1 or V-2.
* Alt text: Criteria table for UL 94 V-0, V-1 and V-2: inclusive individual afterflame limits of 10, 30 and 30 seconds and total limits of 50, 250 and 250 seconds, plus afterglow, clamp and cotton criteria.


== Licensing ==
== Licensing ==
New drawing by Fire Safety Academy. © Fire Safety Academy.
New drawing by Fire Safety Academy. © Fire Safety Academy.
<references />

Latest revision as of 18:25, 23 November 2026

Summary

Main criteria for the UL 94 vertical classes. Time limits are inclusive; the complete prescribed procedure also applies.

Source: [1]

Original illustration for UL 94 flammability test.

  • Alt text: Criteria table for UL 94 V-0, V-1 and V-2: inclusive individual afterflame limits of 10, 30 and 30 seconds and total limits of 50, 250 and 250 seconds, plus afterglow, clamp and cotton criteria.

Licensing

New drawing by Fire Safety Academy. © Fire Safety Academy.

  1. ↑ UL Solutions. Combustion (Fire) Tests for Plastics, “Test criteria for Flammability UL 94 V – 50 W, 20 mm Vertical”. Accessed 23 November 2026.

File history

Click on a date/time to view the file as it appeared at that time.

Date/TimeThumbnailDimensionsUserComment
current18:25, 23 November 2026Thumbnail for version as of 18:25, 23 November 20261,300 × 1,180 (8 KB)Peter (talk | contribs)Watermark: Fire Safety Academy logo icon, 70 px, 45 % opacity
08:12, 8 November 2026Thumbnail for version as of 08:12, 8 November 20261,400 × 990 (9 KB)Lisa (talk | contribs)Watermark: Fire Safety Academy logo icon, 70 px, 45 % opacity

The following page uses this file:

Metadata