Skip to content

File:Fse-fire-propagation-apparatus-v1.svg: Difference between revisions

From Fire Safety Academy Wiki
Lisa (talk | contribs)
Lisa uploaded a new version of File:Fse-fire-propagation-apparatus-v1.svg
Linda (talk | contribs)
Remove bibliographic source lines from image captions and descriptions
 
Line 1: Line 1:
== Summary ==
== Summary ==
The fire propagation apparatus: a specimen on a load cell inside a quartz tube is heated by four infrared heaters while an oxygen and nitrogen mixture flows upwards; products are collected and analysed in the exhaust. Left: horizontal specimen for ignition and combustion tests; right: vertical specimen for fire propagation tests. Based on Tewarson (2002), p. 3-84 and Janssens (2002), p. 3-54.
The fire propagation apparatus: a specimen on a load cell inside a quartz tube is heated by four infrared heaters while an oxygen and nitrogen mixture flows upwards; products are collected and analysed in the exhaust. Left: horizontal specimen for ignition and combustion tests; right: vertical specimen for fire propagation tests.


Original illustration for [[Fire propagation apparatus]].
Original illustration for [[Fire propagation apparatus]].


* Source basis: Tewarson (2002), p. 3-84, Figures 3-4.2(a) and (b) (redraw, do not copy); Janssens (2002), p. 3-54 (tube dimensions, heaters, pilot, gas supply, orifice); Madrzykowski and Stroup (2008), pp. 2-38–2-39, 2-44 (tungsten-quartz heaters, Figure 2.3.7 and 2.3.8, HeNe laser smoke measurement); Tewarson (2002), p. 3-92 (vertical sample, ignition zone 120–200 mm)
* Alt text: Schematic of the fire propagation apparatus: specimen on a load cell in a quartz tube, four infrared heaters, gas inlet below, hood and exhaust duct above.
* Alt text: Schematic of the fire propagation apparatus: specimen on a load cell in a quartz tube, four infrared heaters, gas inlet below, hood and exhaust duct above.


== Licensing ==
== Licensing ==
New drawing by Fire Safety Academy. © Fire Safety Academy.
New drawing by Fire Safety Academy. © Fire Safety Academy.

Latest revision as of 08:31, 8 November 2026

Summary

The fire propagation apparatus: a specimen on a load cell inside a quartz tube is heated by four infrared heaters while an oxygen and nitrogen mixture flows upwards; products are collected and analysed in the exhaust. Left: horizontal specimen for ignition and combustion tests; right: vertical specimen for fire propagation tests.

Original illustration for Fire propagation apparatus.

  • Alt text: Schematic of the fire propagation apparatus: specimen on a load cell in a quartz tube, four infrared heaters, gas inlet below, hood and exhaust duct above.

Licensing

New drawing by Fire Safety Academy. © Fire Safety Academy.

File history

Click on a date/time to view the file as it appeared at that time.

Date/TimeThumbnailDimensionsUserComment
current08:28, 8 November 2026Thumbnail for version as of 08:28, 8 November 20261,800 × 1,270 (16 KB)Lisa (talk | contribs)Watermark: Fire Safety Academy logo icon, 70 px, 45 % opacity
08:15, 8 November 2026Thumbnail for version as of 08:15, 8 November 20261,450 × 1,069 (14 KB)Lisa (talk | contribs)Watermark: Fire Safety Academy logo icon, 70 px, 45 % opacity

The following page uses this file: