Skip to content

File:Fse-wildland-urban-interface-v2.svg: Difference between revisions

From Fire Safety Academy Wiki
Lisa (talk | contribs)
Watermark: Fire Safety Academy logo icon, 70 px, 45 % opacity
 
Mark (talk | contribs)
Correct factcheck 23 Nov 2026, points 15: primary-source corrections, edition context and consistent figures
 
(2 intermediate revisions by the same user not shown)
Line 1: Line 1:
== Summary ==
== Summary ==
Radiant heat fluxes for the ignition of wood and a regulatory limit for building fires. Based on Babrauskas (2003), as cited in National Research Council of Canada et al. (2005), p. 3.3-4, and other sources in the chart data.
Radiant ignition values for [[Wildland-urban interface]]. The quoted 10 kW/m² value is method-specific, not a universal lower limit. RIVM reports piloted ignition of maple at 8 kW/m² after 2680 seconds.


Original vector illustration for [[Wildland-urban interface]], level 2 Intermediate.
Sources for the corrections:
 
* [https://www.rivm.nl/bibliotheek/rapporten/2024-0149.pdf RIVM 2024-0149], p. 81.
* Source basis: as listed in Data
* Other values: sources cited in [[Wildland-urban interface]].
* Alt text: Bars of heat flux in kW per square metre: wood ignition 4.3, 10, 12 and 20; New Zealand boundary limit 30.


== Licensing ==
== Licensing ==
New drawing by Fire Safety Academy. © Fire Safety Academy.
New drawing by Fire Safety Academy. © Fire Safety Academy.

Latest revision as of 18:41, 23 November 2026

Summary

Radiant ignition values for Wildland-urban interface. The quoted 10 kW/m² value is method-specific, not a universal lower limit. RIVM reports piloted ignition of maple at 8 kW/m² after 2680 seconds.

Sources for the corrections:

Licensing

New drawing by Fire Safety Academy. © Fire Safety Academy.

File history

Click on a date/time to view the file as it appeared at that time.

Date/TimeThumbnailDimensionsUserComment
current18:41, 23 November 2026Thumbnail for version as of 18:41, 23 November 2026900 × 600 (9 KB)Mark (talk | contribs)Correct factcheck 23 Nov 2026, points 15: primary-source corrections, edition context and consistent figures
17:45, 2 November 2026Thumbnail for version as of 17:45, 2 November 2026900 × 600 (9 KB)Lisa (talk | contribs)Watermark: Fire Safety Academy logo icon, 70 px, 45 % opacity

The following page uses this file:

Metadata