Failure events in NIST's model of a long-span floor truss under assumed temperatures: the catenary stage starts at 565 °C, connection failures follow up to walk-off at 730 °C. Based on Zarghamee, Bolourchi, et al. (2005), pp. xxxviii–xxxix.
Failure events in NIST's model of a long-span floor truss under assumed temperatures: the catenary stage starts at 565 °C, connection failures follow up to walk-off at 730 °C.


Original illustration for [[Tensile membrane action]], level 4 Expert.
Original illustration for [[Tensile membrane action]], level 4 Expert.


* Source basis: Zarghamee, Bolourchi, et al. (2005), pp. xxxviii–xxxix (truss model C32T1 of Floor 96, WTC 1, assumed temperature history), p. 81 (failure sequence, tension of about 12 kip at about 600 °C, caveat)
* Alt text: Timeline from 0 to 750 °C with failure events of a floor truss model, catenary action at 565 °C and walk-off at 730 °C.
* Alt text: Timeline from 0 to 750 °C with failure events of a floor truss model, catenary action at 565 °C and walk-off at 730 °C.


== Licensing ==
== Licensing ==
New drawing by Fire Safety Academy. © Fire Safety Academy.
New drawing by Fire Safety Academy. © Fire Safety Academy.

Latest revision as of 09:31, 13 November 2026

Summary

Failure events in NIST's model of a long-span floor truss under assumed temperatures: the catenary stage starts at 565 °C, connection failures follow up to walk-off at 730 °C.

Original illustration for Tensile membrane action, level 4 Expert.

  • Alt text: Timeline from 0 to 750 °C with failure events of a floor truss model, catenary action at 565 °C and walk-off at 730 °C.