Skip to content

File:Fse-reduced-cross-section-method-v3.svg: Difference between revisions

From Fire Safety Academy Wiki
Jan (talk | contribs)
Watermark: Fire Safety Academy logo icon, 70 px, 45 % opacity
 
Mark (talk | contribs)
m Remove source references from file description
 
Line 1: Line 1:
== Summary ==
== Summary ==
Remaining section modulus of a 130 mm × 533 mm glued-laminated beam heated on three sides, with a charring rate of 0.7 mm/min, with and without the zero-strength layer. Based on White (2002), pp. 4-261, 4-266 to 4-268.
Remaining section modulus of a 130 mm × 533 mm glued-laminated beam heated on three sides, with a charring rate of 0.7 mm/min, with and without the zero-strength layer.


Original illustration for [[Reduced cross-section method]], level 4 Expert.
Original illustration for [[Reduced cross-section method]], level 4 Expert.


* Source basis: White (2002), pp. 4-261, 4-266, 4-267 and 4-268; calculation by Fire Safety Academy
* Alt text: Line chart of remaining section modulus of a 130 by 533 mm glulam beam over 60 minutes, with and without the zero-strength layer, crossing 50 % near 31 minutes.
* Alt text: Line chart of remaining section modulus of a 130 by 533 mm glulam beam over 60 minutes, with and without the zero-strength layer, crossing 50 % near 31 minutes.


== Licensing ==
== Licensing ==
New drawing by Fire Safety Academy. © Fire Safety Academy.
New drawing by Fire Safety Academy. © Fire Safety Academy.

Latest revision as of 09:23, 13 November 2026

Summary

Remaining section modulus of a 130 mm × 533 mm glued-laminated beam heated on three sides, with a charring rate of 0.7 mm/min, with and without the zero-strength layer.

Original illustration for Reduced cross-section method, level 4 Expert.

  • Alt text: Line chart of remaining section modulus of a 130 by 533 mm glulam beam over 60 minutes, with and without the zero-strength layer, crossing 50 % near 31 minutes.