== Summary ==
== Summary ==
The same frame after the loss of one column. Left: the loads find an alternate path and the damage stays local. Right: the failure spreads from element to element. Based on National Institute of Standards and Technology (2005), p. 206, and Australian Building Codes Board (2020b), p. 91.
The same frame after the loss of one column. Left: the loads find an alternate path and the damage stays local. Right: the failure spreads from element to element.


Original illustration for [[Progressive collapse]], level 4 Expert.
Original illustration for [[Progressive collapse]], level 4 Expert.


* Source basis: National Institute of Standards and Technology (2005), p. 206 (alternate load paths; removal of one or two columns as design initiating event); Australian Building Codes Board (2020b), p. 91 (notional removal of a column; collapse not to extend beyond immediately adjacent storeys); National Institute of Standards and Technology (2008), p. xxxvi (vertical and horizontal progression)
* Alt text: Two elevations of the same six-storey frame with one ground-floor column removed: left, the floors above bridge the gap; right, failure spreads up and sideways.
* Alt text: Two elevations of the same six-storey frame with one ground-floor column removed: left, the floors above bridge the gap; right, failure spreads up and sideways.


== Licensing ==
== Licensing ==
New drawing by Fire Safety Academy. © Fire Safety Academy.
New drawing by Fire Safety Academy. © Fire Safety Academy.

Latest revision as of 09:20, 13 November 2026

Summary

The same frame after the loss of one column. Left: the loads find an alternate path and the damage stays local. Right: the failure spreads from element to element.

Original illustration for Progressive collapse, level 4 Expert.

  • Alt text: Two elevations of the same six-storey frame with one ground-floor column removed: left, the floors above bridge the gap; right, failure spreads up and sideways.

Licensing

New drawing by Fire Safety Academy. © Fire Safety Academy.