Watermark: Fire Safety Academy logo icon, 70 px, 45 % opacity |
m Remove source references from file description |
||
| Line 1: | Line 1: | ||
== Summary == | == Summary == | ||
Parametric fire curves for the office in the worked example with a concrete and a gypsum plaster lining, compared with the ISO 834 standard curve | Parametric fire curves for the office in the worked example with a concrete and a gypsum plaster lining, compared with the ISO 834 standard curve. | ||
Original illustration for [[Parametric fire curve]], level 4 Expert. | Original illustration for [[Parametric fire curve]], level 4 Expert. | ||
* Alt text: Line chart of gas temperature against time: the concrete room peaks near 800 °C, the plaster room near 1,080 °C, the ISO 834 curve keeps rising. | * Alt text: Line chart of gas temperature against time: the concrete room peaks near 800 °C, the plaster room near 1,080 °C, the ISO 834 curve keeps rising. | ||
== Licensing == | == Licensing == | ||
New drawing by Fire Safety Academy. © Fire Safety Academy. | New drawing by Fire Safety Academy. © Fire Safety Academy. | ||
Latest revision as of 09:18, 13 November 2026
Summary
Parametric fire curves for the office in the worked example with a concrete and a gypsum plaster lining, compared with the ISO 834 standard curve.
Original illustration for Parametric fire curve, level 4 Expert.
- Alt text: Line chart of gas temperature against time: the concrete room peaks near 800 °C, the plaster room near 1,080 °C, the ISO 834 curve keeps rising.
Licensing
New drawing by Fire Safety Academy. © Fire Safety Academy.
File history
Click on a date/time to view the file as it appeared at that time.
| Date/Time | Thumbnail | Dimensions | User | Comment | |
|---|---|---|---|---|---|
| current | 17:25, 2 November 2026 | 900 × 600 (25 KB) | Jan (talk | contribs) | Watermark: Fire Safety Academy logo icon, 70 px, 45 % opacity |