Heat release rate inside a room with one door (0.76 m by 2.05 m) against the heat release rate the burning fuel could produce; above about 3.3 MW the fire is ventilation-controlled. Based on Walton and Thomas (2002), p. 3-184, and Gottuk and Lattimer (2002), p. 2-80.
Heat release rate inside a room with one door (0.76 m by 2.05 m) against the heat release rate the burning fuel could produce; above about 3.3 MW the fire is ventilation-controlled.


Original vector illustration for [[Ventilation-controlled fire]], level 2 Intermediate.
Original vector illustration for [[Ventilation-controlled fire]], level 2 Intermediate.


* Source basis: Walton and Thomas (2002), p. 3-184 (Eq. 55); Gottuk and Lattimer (2002), p. 2-80 (Example 6); Australian Building Codes Board (2020a), Data Sheet B1, p. 14 (heat generated outside when pyrolysis exceeds air supply).
* Alt text: Line chart: heat release inside the room rises with the fuel's potential heat release up to 3.3 MW and then stays flat; the excess is shaded as burning outside.
* Alt text: Line chart: heat release inside the room rises with the fuel's potential heat release up to 3.3 MW and then stays flat; the excess is shaded as burning outside.


== Licensing ==
== Licensing ==
New drawing by Fire Safety Academy. © Fire Safety Academy.
New drawing by Fire Safety Academy. © Fire Safety Academy.

Latest revision as of 09:35, 13 November 2026

Summary

Heat release rate inside a room with one door (0.76 m by 2.05 m) against the heat release rate the burning fuel could produce; above about 3.3 MW the fire is ventilation-controlled.

Original vector illustration for Ventilation-controlled fire, level 2 Intermediate.

  • Alt text: Line chart: heat release inside the room rises with the fuel's potential heat release up to 3.3 MW and then stays flat; the excess is shaded as burning outside.