'''Egress stair design''' concerns the geometry, protection and operation of stairs used during escape. It combines safe footing and support with the ability to accommodate the intended population. The SFPE Handbook treats stair movement as part of a connected evacuation system whose speed and flow depend on geometry and crowd conditions.<ref name="NM-3-368–3-372">Nelson and Mowrer (2002), pp. 3-368–3-372.</ref>
'''Egress stair design''' concerns the geometry, protection and operation of stairs used during escape. It combines safe footing and support with the ability to accommodate the intended population. The Society of Fire Protection Engineers (SFPE) Handbook treats stair movement as part of a connected evacuation system whose speed and flow depend on geometry and crowd conditions.<ref name="NM-3-368–3-372">Nelson and Mowrer (2002), pp. 3-368–3-372.</ref>


The NFPA Fire Protection Handbook emphasises prevention of falls, continuity of width, suitable landings and the protection of enclosed stairs. A fall or local restriction can interrupt movement beyond the people immediately involved. Stair design therefore includes both individual use and the collective consequences of obstruction.<ref name="NFPA-§4.3,pp.4-85–4-86">Cote et al. (2008), §4.3, pp. 4-85–4-86.</ref>
The National Fire Protection Association (NFPA) Fire Protection Handbook emphasises prevention of falls, continuity of width, suitable landings and the protection of enclosed stairs. A fall or local restriction can interrupt movement beyond the people immediately involved. Stair design therefore includes both individual use and the collective consequences of obstruction.<ref name="NFPA-§4.3,pp.4-85–4-86">Cote et al. (2008), §4.3, pp. 4-85–4-86.</ref>


[[Exit capacity]], [[Specific flow|specific flow]] and [[Walking speed|walking speed]] describe different aspects of performance. [[Effective width]] connects the physical geometry to a particular movement model. These analytical quantities complement the construction and operating requirements; they do not establish that the stair remains protected from smoke or suitable for every occupant needing assistance.<ref name="NM-3-367–3-372">Nelson and Mowrer (2002), pp. 3-367–3-372.</ref><ref name="NFPA-§4.3,pp.4-85–4-88">Cote et al. (2008), §4.3, pp. 4-85–4-88.</ref>
[[Exit capacity]], [[Specific flow|specific flow]] and [[Walking speed|walking speed]] describe different aspects of performance. [[Effective width]] connects the physical geometry to a particular movement model. These analytical quantities complement the construction and operating requirements; they do not establish that the stair remains protected from smoke or suitable for every occupant needing assistance.<ref name="NM-3-367–3-372">Nelson and Mowrer (2002), pp. 3-367–3-372.</ref><ref name="NFPA-§4.3,pp.4-85–4-88">Cote et al. (2008), §4.3, pp. 4-85–4-88.</ref>
Line 8: Line 8:


A stair must provide a usable sequence of treads and risers. The NFPA handbook links sufficiently deep treads and appropriate steepness with secure footing; it also describes landings that interrupt long flights and rails that support users. These features work together; considering tread dimensions without the rest of the flight would give an incomplete assessment.<ref name="NFPA-§4.3,pp.4-85–4-86" />
A stair must provide a usable sequence of treads and risers. The NFPA handbook links sufficiently deep treads and appropriate steepness with secure footing; it also describes landings that interrupt long flights and rails that support users. These features work together; considering tread dimensions without the rest of the flight would give an incomplete assessment.<ref name="NFPA-§4.3,pp.4-85–4-86" />
[[File:fse-egress-stair-design-v1.svg|thumb|upright=1.5|alt=Egress stair design: footing, landings and protective construction, showing the relationships described in the text.|Footing, landings and protective construction in the assessment of Egress stair design.]]


The handbook distinguishes provisions for new and existing stairs in its historical code account; it notes changes associated with the 2006 edition of NFPA 101. Those dimensions and classifications should therefore retain their edition and building context. They are not presented here as current universal stair requirements.<ref name="NFPA-§4.3,pp.4-85–4-86" />
The handbook distinguishes provisions for new and existing stairs in its historical code account; it notes changes associated with the 2006 edition of NFPA 101. Those dimensions and classifications should therefore retain their edition and building context. They are not presented here as current universal stair requirements.<ref name="NFPA-§4.3,pp.4-85–4-86" />
Line 20: Line 21:


Stair speed is measured along the line of travel. Storey height therefore does not give the complete distance; the sloping flights and landings both contribute; Nelson and Mowrer use stair geometry to select movement coefficients. Applying a level-corridor value to every stair would change the empirical model being used.<ref name="NM-3-370–3-371">Nelson and Mowrer (2002), pp. 3-370–3-371.</ref>
Stair speed is measured along the line of travel. Storey height therefore does not give the complete distance; the sloping flights and landings both contribute; Nelson and Mowrer use stair geometry to select movement coefficients. Applying a level-corridor value to every stair would change the empirical model being used.<ref name="NM-3-370–3-371">Nelson and Mowrer (2002), pp. 3-370–3-371.</ref>
[[File:fse-egress-stair-design-v2.svg|thumb|upright=1.5|alt=Egress stair design: movement, merging and continued use, showing the relationships described in the text.|Movement, merging and continued use in the assessment of Egress stair design.]]


People entering from a floor can merge with those already descending. The combined demand may exceed the downstream stair or door capacity; the SFPE treatment considers different sharing arrangements at a merge, including dominance by one stream. A calculation that assumes equal access should identify that choice rather than treating it as inevitable.<ref name="NM-3-371–3-372">Nelson and Mowrer (2002), pp. 3-371–3-372.</ref>
People entering from a floor can merge with those already descending. The combined demand may exceed the downstream stair or door capacity; the SFPE treatment considers different sharing arrangements at a merge, including dominance by one stream. A calculation that assumes equal access should identify that choice rather than treating it as inevitable.<ref name="NM-3-371–3-372">Nelson and Mowrer (2002), pp. 3-371–3-372.</ref>
Line 29: Line 31:
Maintenance preserves the designed route; the NFPA handbook identifies loose handrails, slippery or loose treads, stored materials and failed enclosure doors as threats to egress. These are changes to the stair's actual performance, even if its nominal dimensions remain unchanged. Inspection therefore includes surfaces, supports, protection and the discharge connection.<ref name="NFPA-§4.3,p.4-90">Cote et al. (2008), §4.3, p. 4-90.</ref>
Maintenance preserves the designed route; the NFPA handbook identifies loose handrails, slippery or loose treads, stored materials and failed enclosure doors as threats to egress. These are changes to the stair's actual performance, even if its nominal dimensions remain unchanged. Inspection therefore includes surfaces, supports, protection and the discharge connection.<ref name="NFPA-§4.3,p.4-90">Cote et al. (2008), §4.3, p. 4-90.</ref>


IFEG divides evacuation measures into physical provisions and emergency organisation. Routes, corridors, exits and signs need an organisation that maintains procedures, education, training and testing. The two groups must reflect the same fire-safety assumptions.<ref name="meansofescap_IFEG-1-8-14">Australian Building Codes Board et al. (2005), pp. 1.8-13–1.8-14.</ref>
International Fire Engineering Guidelines (IFEG) divides evacuation measures into physical provisions and emergency organisation. Routes, corridors, exits and signs need an organisation that maintains procedures, education, training and testing. The two groups must reflect the same fire-safety assumptions.<ref name="meansofescap_IFEG-1-8-14">Australian Building Codes Board et al. (2005), pp. 1.8-13–1.8-14.</ref>


Commissioning should examine both the constructed route and the procedures for using it. Differences between design and construction can require adjustments to the emergency plan. A documented plan that assumes an unavailable route would not provide the intended function.<ref name="meansofescap_IFEG-1-8-14" />
Commissioning should examine both the constructed route and the procedures for using it. Differences between design and construction can require adjustments to the emergency plan. A documented plan that assumes an unavailable route would not provide the intended function.<ref name="meansofescap_IFEG-1-8-14" />
Line 60: Line 62:
== Transitions, queues and changing conditions ==
== Transitions, queues and changing conditions ==


A route commonly includes several elements in series; people may pass from a room into a corridor, through a door and onto a stair. The density and speed can change at each transition even when the same total flow continues. Consequently, assigning one specific-flow value to the entire route can conceal the controlling restriction.<ref name="specificflow_NM-371">Nelson and Mowrer (2002), p. 3-371, equations 4–8 and Table 3-14.5.</ref><ref name="specificflow_NM-372">Nelson and Mowrer (2002), p. 3-372.</ref>
A route commonly includes several elements in series. People may pass from a room into a corridor, through a door and onto a stair. The density and speed can change at each transition even when the same total flow continues. Consequently, assigning one specific-flow value to the entire route can conceal the controlling restriction.<ref name="specificflow_NM-371">Nelson and Mowrer (2002), p. 3-371, equations 4–8 and Table 3-14.5.</ref><ref name="specificflow_NM-372">Nelson and Mowrer (2002), p. 3-372.</ref>


At a merge, incoming total flows are added before comparison with downstream capacity. Specific flows cannot simply be added without accounting for their respective widths. Each incoming specific flow must first be multiplied by its effective width. The resulting total is then assessed against the downstream maximum total flow.<ref name="specificflow_NM-372" />
At a merge, incoming total flows are added before comparison with downstream capacity. Specific flows cannot simply be added without accounting for their respective widths. Each incoming specific flow must first be multiplied by its effective width. The resulting total is then assessed against the downstream maximum total flow.<ref name="specificflow_NM-372" />
Line 95: Line 97:


Occupant characteristics affect route length, preparation, speed and assistance. A route suitable for awake, familiar and independently mobile adults may not serve sleeping occupants or people needing support. The design population should be defined explicitly.<ref name="meansofescap_Proulx-3-350">Proulx (2002), p. 3-350.</ref>
Occupant characteristics affect route length, preparation, speed and assistance. A route suitable for awake, familiar and independently mobile adults may not serve sleeping occupants or people needing support. The design population should be defined explicitly.<ref name="meansofescap_Proulx-3-350">Proulx (2002), p. 3-350.</ref>
[[File:fse-egress-stair-design-v3.svg|thumb|upright=1.5|alt=Egress stair design: occupants and regulatory context, showing the relationships described in the text.|Occupants and regulatory context in the assessment of Egress stair design.]]


Building regulations establish jurisdiction-specific objectives and performance criteria for escape. They can address route number, size, obstruction, protection, illumination and signage. These requirements must be read with the relevant edition and building type.<ref name="meansofescap_IFEG-1-2-18" />
Building regulations establish jurisdiction-specific objectives and performance criteria for escape. They can address route number, size, obstruction, protection, illumination and signage. These requirements must be read with the relevant edition and building type.<ref name="meansofescap_IFEG-1-2-18" />
Line 103: Line 106:


The applicable safety systems can change the escape analysis. Suppression, smoke control and compartmentation may limit exposure, but their required operation must be supported. A design should not rely on an ideal system state while ignoring failure or maintenance.<ref name="meansofescap_IFEG-1-8-14" /><ref name="meansofescap_ABCB-131">Australian Building Codes Board (2020), pp. 131–132.</ref>
The applicable safety systems can change the escape analysis. Suppression, smoke control and compartmentation may limit exposure, but their required operation must be supported. A design should not rely on an ideal system state while ignoring failure or maintenance.<ref name="meansofescap_IFEG-1-8-14" /><ref name="meansofescap_ABCB-131">Australian Building Codes Board (2020), pp. 131–132.</ref>
== See also ==


== Notes ==
== Notes ==

Latest revision as of 00:38, 16 November 2026

Egress stair design concerns the geometry, protection and operation of stairs used during escape. It combines safe footing and support with the ability to accommodate the intended population. The Society of Fire Protection Engineers (SFPE) Handbook treats stair movement as part of a connected evacuation system whose speed and flow depend on geometry and crowd conditions.[1]

The National Fire Protection Association (NFPA) Fire Protection Handbook emphasises prevention of falls, continuity of width, suitable landings and the protection of enclosed stairs. A fall or local restriction can interrupt movement beyond the people immediately involved. Stair design therefore includes both individual use and the collective consequences of obstruction.[2]

Exit capacity, specific flow and walking speed describe different aspects of performance. Effective width connects the physical geometry to a particular movement model. These analytical quantities complement the construction and operating requirements; they do not establish that the stair remains protected from smoke or suitable for every occupant needing assistance.[3][4]

Footing, landings and protective construction

A stair must provide a usable sequence of treads and risers. The NFPA handbook links sufficiently deep treads and appropriate steepness with secure footing; it also describes landings that interrupt long flights and rails that support users. These features work together; considering tread dimensions without the rest of the flight would give an incomplete assessment.[2]

Egress stair design: footing, landings and protective construction, showing the relationships described in the text.
Footing, landings and protective construction in the assessment of Egress stair design.

The handbook distinguishes provisions for new and existing stairs in its historical code account; it notes changes associated with the 2006 edition of NFPA 101. Those dimensions and classifications should therefore retain their edition and building context. They are not presented here as current universal stair requirements.[2]

The width should continue through flights, landings and connected doors without an unexpected restriction; a wide upper flight does not remove a bottleneck lower down. The handbook also addresses doors opening at stairs and the need for appropriate landings. Door movement and the space for people to stand or turn form part of the same geometry.[2]

An exit stair inside a building requires the corresponding enclosure and protected openings. Otherwise the vertical connection can carry smoke between floors. The handbook extends this protection to the route from the stair's bottom to discharge; the enclosure's usefulness depends on doors, service openings and continuity as well as wall construction.[5]

An exterior stair introduces exposure and weather conditions. Nearby windows can expose it to fire, while snow or ice can impair footing. The handbook distinguishes a standard exterior stair from a fire escape with different existing-building provisions; their open-air location alone does not make them equivalent escape components.[5]

Movement, merging and continued use

Stair speed is measured along the line of travel. Storey height therefore does not give the complete distance; the sloping flights and landings both contribute; Nelson and Mowrer use stair geometry to select movement coefficients. Applying a level-corridor value to every stair would change the empirical model being used.[6]

Egress stair design: movement, merging and continued use, showing the relationships described in the text.
Movement, merging and continued use in the assessment of Egress stair design.

People entering from a floor can merge with those already descending. The combined demand may exceed the downstream stair or door capacity; the SFPE treatment considers different sharing arrangements at a merge, including dominance by one stream. A calculation that assumes equal access should identify that choice rather than treating it as inevitable.[7]

Crowd crush is a different endpoint from ordinary queue formation, but congestion is relevant to both route capacity and crowd management. The NFPA handbook warns that one person falling can block a stair. Preventing falls and avoiding local reductions in usable width therefore support the continuing movement of the whole group.[2]

People needing assistance can change the movement pattern. Proulx describes stair users who rest, use handrails or move one step at a time. The reviewed measurements came from participants able to negotiate stairs; those results cannot demonstrate that every person can descend independently or keep pace with the same stream.[8]

Maintenance preserves the designed route; the NFPA handbook identifies loose handrails, slippery or loose treads, stored materials and failed enclosure doors as threats to egress. These are changes to the stair's actual performance, even if its nominal dimensions remain unchanged. Inspection therefore includes surfaces, supports, protection and the discharge connection.[9]

International Fire Engineering Guidelines (IFEG) divides evacuation measures into physical provisions and emergency organisation. Routes, corridors, exits and signs need an organisation that maintains procedures, education, training and testing. The two groups must reflect the same fire-safety assumptions.[10]

Commissioning should examine both the constructed route and the procedures for using it. Differences between design and construction can require adjustments to the emergency plan. A documented plan that assumes an unavailable route would not provide the intended function.[10]

Regular checks should keep paths clear, doors operating and signage in good condition. Lighting and emergency-power functions also need appropriate testing. These checks preserve the physical chain on which the evacuation analysis depends.[10][11] Staff positions and training need to be maintained as well. Procedures should be reviewed, exercises conducted and records kept. Changes in staffing or occupancy can undermine assumptions about directions and assistance.[10]

Alterations should trigger comparison with the original escape design. New partitions, furniture, storage or changed room use can alter distance, capacity and wayfinding. A previously acceptable route may no longer serve the building in its altered form.[12][10]

Purpose and route continuity

The central purpose is timely movement away from a threat. A route begins where occupants may be present and continues through the connected spaces and components leading to safety. Every link must be usable, because a failure near the destination can defeat an otherwise adequate path.[13][14] The threatened end deserves particular attention; Proulx distinguishes an emphasis on exit capacity from an emphasis on the decisions and conditions facing occupants at the start. A route with a safe discharge does not help if occupants cannot recognise or reach it in time.[15]

A place of safety must suit the intended occupants; the 2005 International Fire Engineering Guidelines (IFEG) give an example performance framework for this destination. It describes protection from untenable conditions, suitable communication and enough space for those expected to use it. The destination is therefore part of the escape provision, not an undefined endpoint beyond the exit.[16]

Evacuation uses these provisions within a timed human response. Warning, interpretation and preparation occur before directed travel, and queues can occur along the way. The physical route must be assessed together with those stages rather than in isolation.[17][18]

Route continuity also includes doors and other operating elements. A door that cannot open in the required condition interrupts the path just as a physical obstruction would. Management and maintenance must preserve the route's intended operation.[10]

Protected routes and boundaries

A protected escape route uses construction and closures to limit fire and smoke exposure along the path. The level of protection must support the time for which occupants rely on it. Open stairs and protected exit facilities should not be treated as equivalent without examining the applicable requirements;[19] fire-resistant boundaries can help preserve the route while fire develops elsewhere. Doors and other openings require suitable operation because an open or damaged boundary can compromise that function. The whole assembly matters, not only the wall material.[10][19]

New Zealand's C/VM2 includes a design scenario in which fire in an escape route can block an exit. It asks for a viable route or multiple routes where necessary under the relevant performance criteria. This scenario illustrates why route protection and alternative paths are assessed together.[20]

Radiation can also affect an escape route without direct flame contact. C/VM2 includes an analysis for occupants passing particular window openings, with conditions and limitations specific to that method. Those provisions should not be converted into a universal radiation limit.[21]

A safe place within the building can rely on separation and smoke control. This makes its boundary and ventilation conditions part of the escape system. The occupants must be able to reach and remain in that place for the intended period.[16][17]

Transitions, queues and changing conditions

A route commonly includes several elements in series. People may pass from a room into a corridor, through a door and onto a stair. The density and speed can change at each transition even when the same total flow continues. Consequently, assigning one specific-flow value to the entire route can conceal the controlling restriction.[22][23]

At a merge, incoming total flows are added before comparison with downstream capacity. Specific flows cannot simply be added without accounting for their respective widths. Each incoming specific flow must first be multiplied by its effective width. The resulting total is then assessed against the downstream maximum total flow.[23]

Conservation does not determine how people from competing routes share access; Nelson and Mowrer describe outcomes ranging from shared entry to dominance by one incoming stream. They propose examining different dominance assumptions where the sequence matters. Equal division at a merge is therefore an additional assumption, rather than an inevitable consequence of the flow equations.[23]

When arrivals vary, passage time cannot always be found by dividing the entire population by one maximum rate. The exit may initially be underused, later operate near capacity, and finally empty after the queue clears. Tracking arrivals and departures preserves this sequence. It also distinguishes a capacity limit from an average flow over the whole evacuation.[24][23]

A local reduction in width also changes the space available upstream as a queue develops; the arriving rate can then change because upstream density and speed change. Maintaining the original approach flow indefinitely would ignore that feedback. Nelson and Mowrer's treatment of transitions therefore connects the calculation of each route segment with the neighbouring segments.[24][23]

Interpretation and limitations

The hydraulic relationships summarise observations with empirical scatter; Nelson and Mowrer caution that a calculated movement time is a model result, not a guaranteed actual time. Behaviour, route choice and interruptions can affect the realised flow. Such effects remain relevant when specific-flow equations are embedded in more extensive evacuation modelling.[25][26]

Population characteristics also matter. The ABCB data sheets explicitly state that their doorway-flow equation is not suitable for people with mobility impairment. Their speed discussion requires further reductions for older people and those with restricted mobility. A general-population maximum cannot be used as evidence that an assisted evacuation will achieve the same throughput.[27][28]

Much of the movement evidence discussed by Nelson and Mowrer concerns smoke-free conditions. Smoke can reduce visibility and affect the eyes, changing movement performance. Their discussion distinguishes these influences from crowd density; applying an unobstructed flow curve does not establish either movement capability or acceptable exposure in a smoke-filled route.[23]

A numerical maximum describes movement under the model's assumptions; it is not a complete performance criterion. The same throughput can be associated with different queue locations and different waiting times for particular groups. Merge dominance can especially affect which occupants leave first. Total discharge alone cannot describe those differences in individual experience.[22][23]

A useful interpretation therefore preserves the complete chain of assumptions; the population, density range, route type, effective width and arrival pattern must match the calculation. Its result describes flow under those stated conditions. Claims about total evacuation performance require the remaining time components and the conditions along the route to be assessed as well.[25][24][28]

What the hydraulic representation includes

The hydraulic analogy treats a group as a stream passing through connected route elements. Corridors, doors and stairs have geometries that influence the stream's speed and flow; the approach focuses on quantities that can be expressed consistently across these elements. It does not imply that people behave as an actual liquid.[29][30]

Nelson and Mowrer identify three common assumptions: occupants begin together, decisions do not interrupt the flow, and most people can keep pace with the group. These assumptions simplify the movement problem. They also define important limits on the interpretation of its output. A population requiring assistance cannot automatically be represented by the same unrestricted stream.[29]

The calculated movement duration contributes to required safe egress time. Other components account for detection, notification, decisions and the interval before evacuation starts; a short flow calculation is therefore compatible with a much longer total response. Comparing its movement output directly with fire development would omit those additional periods.[29]

The source distinguishes modelled movement time from actual evacuation performance; it describes the calculation as a reproducible baseline for examining routes or changes to a system. Actual movement often takes longer because of interruptions and uneven use, but the source also recognises the opposite possibility. The hydraulic result is consequently not an automatic lower bound for every observed event.[31]

Occupants and regulatory context

Occupant characteristics affect route length, preparation, speed and assistance. A route suitable for awake, familiar and independently mobile adults may not serve sleeping occupants or people needing support. The design population should be defined explicitly.[32]

Egress stair design: occupants and regulatory context, showing the relationships described in the text.
Occupants and regulatory context in the assessment of Egress stair design.

Building regulations establish jurisdiction-specific objectives and performance criteria for escape. They can address route number, size, obstruction, protection, illumination and signage. These requirements must be read with the relevant edition and building type.[13]

IFEG reproduces historical New Zealand performance criteria for escape routes. These address route size, obstruction, length, fire-spread resistance, findability, illumination and safe use. They illustrate related design functions; the excerpt is not presented as the current text of New Zealand law.[13]

C/VM2 provides one verification method within the New Zealand context. Its 2025 travel and flow procedures include particular inputs and restrictions, such as door-flow provisions. Those values belong to the method and should not be treated as international defaults.[14]

The applicable safety systems can change the escape analysis. Suppression, smoke control and compartmentation may limit exposure, but their required operation must be supported. A design should not rely on an ideal system state while ignoring failure or maintenance.[10][33]

Notes

  1. ↑ Nelson and Mowrer (2002), pp. 3-368–3-372.
  2. ↑ 2.0 2.1 2.2 2.3 2.4 Cote et al. (2008), §4.3, pp. 4-85–4-86.
  3. ↑ Nelson and Mowrer (2002), pp. 3-367–3-372.
  4. ↑ Cote et al. (2008), §4.3, pp. 4-85–4-88.
  5. ↑ 5.0 5.1 Cote et al. (2008), §4.3, pp. 4-86–4-87.
  6. ↑ Nelson and Mowrer (2002), pp. 3-370–3-371.
  7. ↑ Nelson and Mowrer (2002), pp. 3-371–3-372.
  8. ↑ Proulx (2002), pp. 3-360–3-361.
  9. ↑ Cote et al. (2008), §4.3, p. 4-90.
  10. ↑ 10.0 10.1 10.2 10.3 10.4 10.5 10.6 10.7 Australian Building Codes Board et al. (2005), pp. 1.8-13–1.8-14.
  11. ↑ Razza and Grill (2005), pp. 3–4.
  12. ↑ Ministry of Business, Innovation and Employment (2025), p. 32.
  13. ↑ 13.0 13.1 13.2 Australian Building Codes Board et al. (2005), p. 1.2-18.
  14. ↑ 14.0 14.1 Ministry of Business, Innovation and Employment (2025), pp. 32–33.
  15. ↑ Proulx (2002), pp. 3-342–3-343.
  16. ↑ 16.0 16.1 Australian Building Codes Board et al. (2005), p. 1.2-15.
  17. ↑ 17.0 17.1 Australian Building Codes Board et al. (2005), pp. 2.8-1–2.8-2.
  18. ↑ Proulx (2002), pp. 3-347–3-348.
  19. ↑ 19.0 19.1 Australian Building Codes Board et al. (2005), pp. 1.2-16–1.2-17.
  20. ↑ Ministry of Business, Innovation and Employment (2025), p. 37.
  21. ↑ Ministry of Business, Innovation and Employment (2025), pp. 34–36.
  22. ↑ 22.0 22.1 Nelson and Mowrer (2002), p. 3-371, equations 4–8 and Table 3-14.5.
  23. ↑ 23.0 23.1 23.2 23.3 23.4 23.5 23.6 Nelson and Mowrer (2002), p. 3-372.
  24. ↑ 24.0 24.1 24.2 Nelson and Mowrer (2002), p. 3-369.
  25. ↑ 25.0 25.1 Nelson and Mowrer (2002), pp. 3-367–3-368.
  26. ↑ Nelson and Mowrer (2002), pp. 3-368–3-369.
  27. ↑ Australian Building Codes Board (2020), p. 278, §1.5.2.
  28. ↑ 28.0 28.1 Australian Building Codes Board (2020), p. 280, Table 21 and §1.5.3.
  29. ↑ 29.0 29.1 29.2 Nelson and Mowrer (2002), pp. 3-367–3-368.
  30. ↑ Nelson and Mowrer (2002), pp. 3-370–3-372.
  31. ↑ Nelson and Mowrer (2002), p. 3-368.
  32. ↑ Proulx (2002), p. 3-350.
  33. ↑ Australian Building Codes Board (2020), pp. 131–132.

References

  • Australian Building Codes Board, National Research Council of Canada, International Code Council, & Department of Building and Housing New Zealand. (2005). International fire engineering guidelines. Australian Building Codes Board.
  • Australian Building Codes Board. (2020). Fire safety verification method: Data sheets (Handbook annex, Print version 1.1).
  • Cote, A. E., Grant, C. C., Hall, J. R., Jr., & Solomon, R. E. (Eds.). (2008). Fire protection handbook (20th ed.). National Fire Protection Association.
  • Ministry of Business, Innovation and Employment. (2025). C protection from fire: Verification method C/VM2 (2nd ed.).
  • Nelson, H. E., & Mowrer, F. W. (2002). Emergency movement. In P. J. DiNenno (Ed.), SFPE handbook of fire protection engineering (3rd ed., pp. 3-367–3-380). National Fire Protection Association.
  • Proulx, G. (2002). Movement of people: The evacuation timing. In P. J. DiNenno (Ed.), SFPE handbook of fire protection engineering (3rd ed., pp. 3-342–3-366). National Fire Protection Association.
  • Razza, J. C., & Grill, R. A. (2005). Comparison of the 1968 and current (2003) New York City building code provisions (NIST NCSTAR 1-1F). National Institute of Standards and Technology.