Add watermarked Fire Safety Academy illustration at the location specified in the visual plan |
Wiki review: corrected 2 errors: grammar (2) (Claude Opus 5.5) |
||
| (2 intermediate revisions by 2 users not shown) | |||
| Line 13: | Line 13: | ||
== Scale of the problem == | == Scale of the problem == | ||
In US [[fire statistics]] for all structure fires in 1999–2002, smoking materials caused 35,100 fires a year (7 percent) and 890 civilian deaths (28 percent); the estimates exclude 11 September 2001.<ref name="HallCote-3-14" /> This made them the number one cause of civilian fire deaths, most of which began with the ignition of upholstered furniture, mattresses or bedding. In US homes, smoking materials caused 24,800 home structure fires a year (7 percent) but 850 deaths (29 percent), or 3.4 civilian deaths per 100 fires.<ref name="Ahrens-3-74" /> All home structure fires together caused 2,960 deaths in 372,900 fires, about 0.79 deaths per 100 fires, so a smoking-material fire was about four times as deadly as the average.<ref name="Ahrens-3-75">Ahrens et al. (2008), p. 3-75.</ref> In one- and two-family dwellings smoking materials | In US [[fire statistics]] for all structure fires in 1999–2002, smoking materials caused 35,100 fires a year (7 percent) and 890 civilian deaths (28 percent); the estimates exclude 11 September 2001.<ref name="HallCote-3-14" /> This made them the number one cause of civilian fire deaths, most of which began with the ignition of upholstered furniture, mattresses or bedding. In US homes, smoking materials caused 24,800 home structure fires a year (7 percent) but 850 deaths (29 percent), or 3.4 civilian deaths per 100 fires.<ref name="Ahrens-3-74" /> All home structure fires together caused 2,960 deaths in 372,900 fires, about 0.79 deaths per 100 fires, so a smoking-material fire was about four times as deadly as the average.<ref name="Ahrens-3-75">Ahrens et al. (2008), p. 3-75.</ref> In one- and two-family dwellings smoking materials were the leading cause of fire deaths, with 640 deaths a year (26 percent), while ranking fifth by number of fires.<ref name="Lathrop-20-57">Lathrop (2008b), p. 20-57.</ref><ref name="Lathrop-20-58" /> | ||
[[File:fse-smoking-material-fire-v1.svg|thumb|upright=1.5|alt=Paired horizontal bars comparing share of fires and share of deaths for leading causes of US home fires, 1999 to 2002|Share of fires and of civilian deaths by leading cause, US home structure fires, 1999–2002 annual averages. Smoking materials cause 7 percent of the fires but 29 percent of the deaths.]] | |||
The items first ignited explain much of this toll. In US home fires that began in upholstered furniture in 1999–2002, cigarettes were the heat source in 34 percent of the fires and 49 percent of the deaths.<ref name="Babrauskas-6-106" /> For fires that began in mattresses or bedding, cigarettes accounted for 22 percent of the fires and 44 percent of the deaths.<ref name="Babrauskas-6-107">Babrauskas (2008b), p. 6-107.</ref> Together these two item groups lost about 460 lives a year to cigarette ignitions. | The items first ignited explain much of this toll. In US home fires that began in upholstered furniture in 1999–2002, cigarettes were the heat source in 34 percent of the fires and 49 percent of the deaths.<ref name="Babrauskas-6-106" /> For fires that began in mattresses or bedding, cigarettes accounted for 22 percent of the fires and 44 percent of the deaths.<ref name="Babrauskas-6-107">Babrauskas (2008b), p. 6-107.</ref> Together these two item groups lost about 460 lives a year to cigarette ignitions. | ||
| Line 19: | Line 20: | ||
In US nonhome structures, smoking materials caused 9,900 fires a year (7 percent) and 40 deaths (24 percent).<ref name="HallCote-3-16">Hall and Cote (2008), p. 3-16.</ref> In hotels and motels they caused 16 percent of the fires and 9 deaths a year, which was 56 percent of all hotel and motel fire deaths.<ref name="Berkol-20-27">Berkol et al. (2008), p. 20-27.</ref> In 1994–1998, smoking materials and incendiary or suspicious acts together caused 75 percent of the deaths in US facilities that care for the sick.<ref name="OConnor-20-140" /> | In US nonhome structures, smoking materials caused 9,900 fires a year (7 percent) and 40 deaths (24 percent).<ref name="HallCote-3-16">Hall and Cote (2008), p. 3-16.</ref> In hotels and motels they caused 16 percent of the fires and 9 deaths a year, which was 56 percent of all hotel and motel fire deaths.<ref name="Berkol-20-27">Berkol et al. (2008), p. 20-27.</ref> In 1994–1998, smoking materials and incendiary or suspicious acts together caused 75 percent of the deaths in US facilities that care for the sick.<ref name="OConnor-20-140" /> | ||
Older US series show a decline. In 1980, smoking and heating | Older US series show a decline. In 1980, smoking and heating were the two leading causes of home fire deaths, and both declined rapidly in the following decades.<ref name="Hall-5-108">Hall (2008), p. 5-108.</ref> Deaths from smouldering ignitions of upholstered furniture fell from about 1,000 a year in the early 1980s to about 600 by the mid-1990s.<ref name="Babrauskas-6-113">Babrauskas (2008b), p. 6-113.</ref> The 2008 handbook reported the highest cigarette-fire death rate among people aged 65 or older, although they were only half as likely to smoke as younger adults.<ref name="Gamache-5-69">Gamache (2008), p. 5-69.</ref> | ||
== How a cigarette starts a fire == | == How a cigarette starts a fire == | ||
| Line 31: | Line 32: | ||
The [[smouldering-to-flaming transition]] does not happen in every case. When it does, times of 22 minutes to several hours from placing the cigarette to the first flames have been reported.<ref name="Babrauskas-6-109" /> In tests with a cotton mattress, smouldering turned to flaming in two of five tests after 65 to 80 minutes, and in other bedding and upholstery tests the transition usually took 2 to 3 hours.<ref name="Ohlemiller-2-206" /> | The [[smouldering-to-flaming transition]] does not happen in every case. When it does, times of 22 minutes to several hours from placing the cigarette to the first flames have been reported.<ref name="Babrauskas-6-109" /> In tests with a cotton mattress, smouldering turned to flaming in two of five tests after 65 to 80 minutes, and in other bedding and upholstery tests the transition usually took 2 to 3 hours.<ref name="Ohlemiller-2-206" /> | ||
[[File:fse-smoking-material-fire-v2.svg|thumb|upright=1.5|alt=Timeline diagram from a cigarette in a chair crevice through smouldering and carbon monoxide build-up to possible flaming|Typical course of a cigarette-initiated fire in upholstered furniture: a 5 W source starts smouldering that may turn to flaming after 22 minutes to several hours, or go out.]] | |||
== Hazards to occupants == | == Hazards to occupants == | ||
| Line 36: | Line 38: | ||
Tests at the US National Institute of Standards and Technology (NIST) illustrate this. Armchairs of polyurethane foam with cotton covers, with a combustible mass of 5.7 kg, were ignited by one or two cigarettes in the seat angle in a simulated small apartment of 101 m³.<ref name="Purser-2-134" /> About 1 kg of foam decomposed in just over an hour of smouldering. CO in the 11.8 m³ burn room rose from 180 ppm in the first 13 minutes to 1,000 ppm between 67 and 75 minutes. Cumulative exposure could cause loss of consciousness there after just over an hour, but probably not in the target room. Once the chairs flamed, a person in the target room would have lost consciousness within a minute.<ref name="Purser-2-134" /> | Tests at the US National Institute of Standards and Technology (NIST) illustrate this. Armchairs of polyurethane foam with cotton covers, with a combustible mass of 5.7 kg, were ignited by one or two cigarettes in the seat angle in a simulated small apartment of 101 m³.<ref name="Purser-2-134" /> About 1 kg of foam decomposed in just over an hour of smouldering. CO in the 11.8 m³ burn room rose from 180 ppm in the first 13 minutes to 1,000 ppm between 67 and 75 minutes. Cumulative exposure could cause loss of consciousness there after just over an hour, but probably not in the target room. Once the chairs flamed, a person in the target room would have lost consciousness within a minute.<ref name="Purser-2-134" /> | ||
[[File:fse-smoking-material-fire-v4.svg|thumb|upright=1.5|alt=Step chart of carbon monoxide in a burn room rising from 180 to 1000 ppm over 75 minutes of smouldering and then to 10000 ppm on flaming|Carbon monoxide in the burn room during cigarette-initiated smouldering of a standard foam armchair, followed by flaming, in NIST tests.]] | |||
The people at risk are often not the smokers themselves. In most fatal US home fires the victims were outside the room of fire origin, and this was also true for a large minority of smoking fire deaths.<ref name="Babrauskas-6-105">Babrauskas (2008b), p. 6-105.</ref> For victims aged 19 to 49, deaths were 20 times more likely in fires that burned for 30 minutes or more before discovery than in fires found within 5 minutes.<ref name="Purser-2-134" /> In US health care facilities, by contrast, most victims were intimate with ignition, and most of those fires began on their clothing or on the bedding or furniture on which they lay.<ref name="OConnor-20-140" /> | The people at risk are often not the smokers themselves. In most fatal US home fires the victims were outside the room of fire origin, and this was also true for a large minority of smoking fire deaths.<ref name="Babrauskas-6-105">Babrauskas (2008b), p. 6-105.</ref> For victims aged 19 to 49, deaths were 20 times more likely in fires that burned for 30 minutes or more before discovery than in fires found within 5 minutes.<ref name="Purser-2-134" /> In US health care facilities, by contrast, most victims were intimate with ignition, and most of those fires began on their clothing or on the bedding or furniture on which they lay.<ref name="OConnor-20-140" /> | ||
| Line 70: | Line 73: | ||
After two hours the total is about 1.5 + 0.073 × 60 ≈ 5.9 kg. For comparison, a NIST armchair lost about 1 kg in just over an hour of cigarette-initiated smouldering, so the model describes a larger source than that single chair.<ref name="Purser-2-134" /> The Australian data sheets add that measured data may suit detector activation and tenability better, and they call for separate CO tenability criteria.<ref name="ABCBDS-B1-10">Australian Building Codes Board (2020a), Data Sheet B1, pp. 9–10.</ref> | After two hours the total is about 1.5 + 0.073 × 60 ≈ 5.9 kg. For comparison, a NIST armchair lost about 1 kg in just over an hour of cigarette-initiated smouldering, so the model describes a larger source than that single chair.<ref name="Purser-2-134" /> The Australian data sheets add that measured data may suit detector activation and tenability better, and they call for separate CO tenability criteria.<ref name="ABCBDS-B1-10">Australian Building Codes Board (2020a), Data Sheet B1, pp. 9–10.</ref> | ||
[[File:fse-smoking-material-fire-v3.svg|thumb|upright=1.5|alt=Line chart of smouldering pyrolysis rate rising to 73 grams per minute at one hour and then constant, with cumulative mass loss|Pyrolysis rate (left axis) and cumulative mass loss (right axis) of the smouldering design fire of Quintiere and co-workers, 0–120 min.]] | |||
A second estimate shows how slowly a smouldering bed develops. In the cotton mattress tests, the smoulder front spread outwards at about 6.3 × 10<sup>−5</sup> m/s.<ref name="Ohlemiller-2-206" /> The radius of the smouldering patch is then <math>r = v\,t</math>, about 0.25 m after 65 minutes and 0.30 m after 80 minutes. The smouldering area <math>\pi r^2</math> is only 0.19 to 0.29 m² when flaming may begin, and many smouldering fires become flaming fires before anyone detects them.<ref name="Purser-2-134" /> | A second estimate shows how slowly a smouldering bed develops. In the cotton mattress tests, the smoulder front spread outwards at about 6.3 × 10<sup>−5</sup> m/s.<ref name="Ohlemiller-2-206" /> The radius of the smouldering patch is then <math>r = v\,t</math>, about 0.25 m after 65 minutes and 0.30 m after 80 minutes. The smouldering area <math>\pi r^2</math> is only 0.19 to 0.29 m² when flaming may begin, and many smouldering fires become flaming fires before anyone detects them.<ref name="Purser-2-134" /> | ||
Latest revision as of 00:36, 16 November 2026
A smoking-material fire is a fire started by a lighted tobacco product, such as a cigarette, cigar or pipe.[1][2] In fire statistics the term names a heat-source category: it describes what supplied the ignition energy, not what burned or who was to blame.[3] A burning cigarette releases only about 5 W, yet it can start smouldering in upholstered furniture, mattresses and bedding that may later burst into flame.[4][5] Because such fires can smoulder for hours, many fatal cases happen at night while the occupants are asleep.[6]
In the United States in 1999–2002, smoking materials caused about 7 percent of reported home structure fires but 29 percent of home fire deaths, the largest share of any cause.[7] Prevention works on three fronts: cigarettes that go out when left alone, furniture and mattresses that resist cigarette ignition, and smoke alarms that warn sleeping occupants.[8][9] New Zealand's 2025 C/VM2 verification method and Australia's 2020 FSVM handbook each specify a smouldering-fire design scenario for sleeping areas.[10][11]
Definition and classification
The US National Fire Incident Reporting System (NFIRS) has six cause-related data fields, from the general cause to the item first ignited.[12] Smoking materials belong to the heat-source element, which identifies the ignition source of the fire.[8] Heat-source categories in this group include "cigarette", "pipe or cigar" and "heat from undetermined smoking material".[2] Some data series, such as the 1994–1998 health care data, also count the matches and lighters used to light tobacco.[13]
National estimates depend on how vague entries are handled. NFIRS has a code for "other open flame or smoking material", and the National Fire Protection Association (NFPA) shares these fires out over its open-flame and smoking categories in proportion to the known cases.[14] Without this secondary allocation, intentional fires would overtake smoking materials as the leading cause of home fire deaths. Before NFIRS version 5.0, open flames and smoking materials were separate categories, so long trend lines mix two coding systems.
Sorting rules also matter. Under an older hierarchy of the US Fire Administration, an incendiary fire started with a cigarette was counted as incendiary and not as a smoking-material fire.[15] A fire started by a child playing with cigarettes can be placed under either heading.[7] Among the factors contributing to ignition, "abandoned or discarded materials or products" accounted for 8 percent of US home fires in 1999–2002, a code that often refers to smoking materials.[16]
The label says nothing about blame. A hostile fire needs a heat source, a first fuel and usually a human error, so the fire cause can be ranked by any of the three.[8] Smokers who never smoked in bed and always used sturdy ashtrays would have avoided most of these deaths. More ignition-resistant furniture and bedding, or cigarettes that self-extinguish sooner, might also have prevented many or most of them.[3] Analysts are therefore advised to choose the description that supports a workable prevention strategy.
Scale of the problem
In US fire statistics for all structure fires in 1999–2002, smoking materials caused 35,100 fires a year (7 percent) and 890 civilian deaths (28 percent); the estimates exclude 11 September 2001.[8] This made them the number one cause of civilian fire deaths, most of which began with the ignition of upholstered furniture, mattresses or bedding. In US homes, smoking materials caused 24,800 home structure fires a year (7 percent) but 850 deaths (29 percent), or 3.4 civilian deaths per 100 fires.[7] All home structure fires together caused 2,960 deaths in 372,900 fires, about 0.79 deaths per 100 fires, so a smoking-material fire was about four times as deadly as the average.[17] In one- and two-family dwellings smoking materials were the leading cause of fire deaths, with 640 deaths a year (26 percent), while ranking fifth by number of fires.[18][6]
The items first ignited explain much of this toll. In US home fires that began in upholstered furniture in 1999–2002, cigarettes were the heat source in 34 percent of the fires and 49 percent of the deaths.[2] For fires that began in mattresses or bedding, cigarettes accounted for 22 percent of the fires and 44 percent of the deaths.[19] Together these two item groups lost about 460 lives a year to cigarette ignitions.
In US nonhome structures, smoking materials caused 9,900 fires a year (7 percent) and 40 deaths (24 percent).[20] In hotels and motels they caused 16 percent of the fires and 9 deaths a year, which was 56 percent of all hotel and motel fire deaths.[21] In 1994–1998, smoking materials and incendiary or suspicious acts together caused 75 percent of the deaths in US facilities that care for the sick.[13]
Older US series show a decline. In 1980, smoking and heating were the two leading causes of home fire deaths, and both declined rapidly in the following decades.[22] Deaths from smouldering ignitions of upholstered furniture fell from about 1,000 a year in the early 1980s to about 600 by the mid-1990s.[23] The 2008 handbook reported the highest cigarette-fire death rate among people aged 65 or older, although they were only half as likely to smoke as younger adults.[24]
How a cigarette starts a fire
Smouldering is a slow, low-temperature, flameless form of combustion, sustained by the heat released when oxygen attacks the surface of a solid fuel.[5] A burning cigarette is itself a familiar example of smouldering, and it is one of the most common starters of smouldering in upholstery and bedding. The tobacco first forms a char, which oxidises readily at moderate temperatures of about 670 K. Introduction to Fire Safety Engineering treats smouldering as one of the two forms of combustion, next to flaming.[25]
As an ignition source a cigarette is weak but long-lasting. A 1.1 g cigarette lying unpuffed on a solid surface has a typical heat output of 5 W, burns for about 1,200 s and gives a maximum heat flux of 35 to 42 kW/m².[4] A wooden match gives 80 W, but only for 20 to 30 s. Multiplying power by duration gives about 6 kJ for the cigarette against 1.6 to 2.4 kJ for the match. An average living-room sofa can reach 2.5 MW, about 500,000 times the output of the cigarette that may have ignited it.[26] In a cigarette lying in open air, the smoulder front moves at 0.03 to 0.05 mm/s, with a peak temperature of about 820 °C.[27]
Whether the cigarette ignites its target depends mainly on the fabric and padding it touches. Medium and heavy synthetic thermoplastic fabrics such as nylon, olefin and polyester generally resist cigarettes, while cellulosic fabrics such as cotton, linen and rayon do not.[28] In small-scale tests on retail furniture, about 39 percent of items covered in cellulosic fabrics resisted cigarette smouldering, against about 95 percent of items covered in thermoplastic fabrics.[2] A pure cellulosic fabric heavier than 440 g/m² (13 oz/yd²) finds it very difficult to pass a cigarette test.[29] A cellulosic fabric over polyurethane foam can smoulder over a much wider range of conditions than the foam alone.[30]
The geometry of the item matters as well. Crevices in furniture, such as the junction of seat cushion, armrests and back, are more easily ignited by a cigarette than the flat surfaces of a mattress.[19] On a bed, however, sheets, blankets or pillows may cover a dropped cigarette, which raises the probability of ignition. This is one reason why mattress flammability is harder to test than the flammability of furniture. Once an upholstered furniture fire starts flaming, a single item with a high enough burning rate and enough oxygen can bring a room to flashover.[31]
The smouldering-to-flaming transition does not happen in every case. When it does, times of 22 minutes to several hours from placing the cigarette to the first flames have been reported.[31] In tests with a cotton mattress, smouldering turned to flaming in two of five tests after 65 to 80 minutes, and in other bedding and upholstery tests the transition usually took 2 to 3 hours.[30]
Hazards to occupants
The main danger of a smouldering fire is poisoning by carbon monoxide (CO). Smouldering decomposes materials at relatively low temperatures of about 400 °C and favours incomplete oxidation, so the ratio of carbon dioxide to CO approaches one.[32] CO is produced slowly, but smouldering fires do not mix and dilute their products vigorously with room air. Lethal CO concentrations can therefore build up close to the item within 10 minutes, while elsewhere in the room this may take 1 to 3 hours.[33]
Tests at the US National Institute of Standards and Technology (NIST) illustrate this. Armchairs of polyurethane foam with cotton covers, with a combustible mass of 5.7 kg, were ignited by one or two cigarettes in the seat angle in a simulated small apartment of 101 m³.[32] About 1 kg of foam decomposed in just over an hour of smouldering. CO in the 11.8 m³ burn room rose from 180 ppm in the first 13 minutes to 1,000 ppm between 67 and 75 minutes. Cumulative exposure could cause loss of consciousness there after just over an hour, but probably not in the target room. Once the chairs flamed, a person in the target room would have lost consciousness within a minute.[32]
The people at risk are often not the smokers themselves. In most fatal US home fires the victims were outside the room of fire origin, and this was also true for a large minority of smoking fire deaths.[34] For victims aged 19 to 49, deaths were 20 times more likely in fires that burned for 30 minutes or more before discovery than in fires found within 5 minutes.[32] In US health care facilities, by contrast, most victims were intimate with ignition, and most of those fires began on their clothing or on the bedding or furniture on which they lay.[13]
The sources do not fully agree on how often smouldering itself is fatal. The handbook chapter on upholstered furniture states that smouldering items rarely kill before the fire turns to flaming, goes out or is put out.[31] A review of closed-room tests found that a lethal CO dose and the transition to flaming were about equally likely between 1 and 2.5 hours after cigarette ignition.[30] A model study of national statistics suggested instead that deaths mostly followed the transition to flaming.[27]
Design fires and engineering analysis
In fire engineering, a smoking-material fire is a typical design fire scenario for dwellings and sleeping areas. The International Fire Engineering Guidelines (IFEG) list smoking materials, electrical equipment and heating appliances among the ignition sources to be reviewed in a fire engineering brief.[35] An example set of scenarios for a single-family house in the NFPA handbook includes a cigarette igniting upholstered furniture as a common smouldering fire.[36]
In an IFEG schematic fire that does not turn to flaming, maximum heat release rate is typically less than 5 kW.[37] The time to the transition to flaming cannot be calculated with certainty, so flaming design fires are usually assumed to start without a smouldering phase.[38] Zone models are not suited to a fire as small as a burning cigarette in a normal room.[39] The 2020 Australian data sheets list historic dwelling-fire shares of 18.7–27.0 percent smouldering fires across Australia, the United States, Canada and New Zealand.[40]
Where a smouldering source must be quantified, the IFEG gives a simple model by Quintiere and co-workers for the rate at which fuel mass is lost. The rate grows during the first hour, partly in proportion to time and partly to time squared, and then stays constant until the end of the second hour.[41] The same model, with the same coefficients, appears in the Australian design fire data sheets.[42]
| Symbol | Description | Unit |
|---|---|---|
| pyrolysis rate (rate of mass loss) of the smouldering fuel | g/min | |
| time from the start of smouldering | min | |
| coefficient, 0.10 | g/min² | |
| coefficient, 0.0185 | g/min³ | |
| constant pyrolysis rate in the second hour, 73 | g/min |
As a worked example, the model gives a mass loss rate of about 19.7 g/min after 30 minutes.[41] After 60 minutes the rate is 72.6 g/min, which matches the constant 73 g/min of the second hour. Integrating the first equation over the first hour gives the fuel consumed:
After two hours the total is about 1.5 + 0.073 × 60 ≈ 5.9 kg. For comparison, a NIST armchair lost about 1 kg in just over an hour of cigarette-initiated smouldering, so the model describes a larger source than that single chair.[32] The Australian data sheets add that measured data may suit detector activation and tenability better, and they call for separate CO tenability criteria.[43]
A second estimate shows how slowly a smouldering bed develops. In the cotton mattress tests, the smoulder front spread outwards at about 6.3 × 10−5 m/s.[30] The radius of the smouldering patch is then , about 0.25 m after 65 minutes and 0.30 m after 80 minutes. The smouldering area is only 0.19 to 0.29 m² when flaming may begin, and many smouldering fires become flaming fires before anyone detects them.[32]
Verification methods address this scenario through detection and, where needed, comparative analysis. In New Zealand, C/VM2 (second edition, 2025) contains scenario SF, a fire smouldering close to a sleeping area.[10] Compliance is shown by automatic fire detection and alarm throughout the building, with smoke detection in sleeping areas to NZS 4512; no further analysis is expected. Australia's Fire Safety Verification Method handbook (2020) compares time to detection and available safe egress time with those of a reference building.[11] It says CO exposure is generally the critical tenability criterion. For residential buildings, smoke detection and alarms are generally the only viable mitigation, although a performance solution may include other measures such as sprinklers.[11]
Prevention and protection
One strategy is to change the cigarette. A fire-safe cigarette has a reduced propensity to keep burning when left unattended.[44] After the US Cigarette Safety Act of 1984 and the Fire Safe Cigarette Act of 1990, NIST concluded that such cigarettes were feasible and practicable and developed the test method that became ASTM E2187. In July 2000, one manufacturer began making banded-paper cigarettes; their ignition probability still ranged from 3 to 50 percent, depending on the test substrate.[44] New York required reduced-ignition cigarettes from 28 June 2004 and Canada from 1 October 2005. By the end of 2006, six US states covering 25.9 percent of the population had passed such laws, some with later effective dates.[24] A change in cigarettes reaches the market within months, whereas changes in furniture may take decades to work through the existing stock.[45]
The other product strategy is to make the target fuel harder to ignite. The 2008 handbook describes a US federal test for mattresses made from June 1973, 16 CFR Part 1632, using nine cigarettes on the bare mattress and nine between two sheets.[46] Furniture instead used the voluntary programme of the Upholstered Furniture Action Council (UFAC). By the mid-1990s, 86 percent of upholstered seating on sale met its requirements; CPSC estimated that a cigarette on any mid-1990s furniture item had about an 85 percent chance of failing to ignite it.[44] The handbook also describes UK regulations of the late 1980s mandating resistance to both cigarettes and small flames.[19]
Detection is the main protection for sleeping occupants. As a class, photoelectric smoke alarms respond faster to smouldering fires, while ionisation alarms respond faster to open flaming fires.[9] Fitting a smoke alarm of each type gives an extra margin, at the cost of more nuisance alarms. The development of residential sprinklers drew on data showing that fatal ignitions of furniture and bedding most often came from a smouldering source or a small flame.[47] In September 1991, an abandoned cigarette ignited boxes in a basement office of the World Trade Center; the sprinkler system operated and the damage stayed in the area of origin.[48]
Management controls matter where occupants are vulnerable or supervised. In US health care facilities, the handbook recommends banning smoking wherever flammable liquids, combustible gases or oxygen are used or stored. It recommends metal containers with self-closing covers wherever smoking is allowed.[49] It says the Joint Commission then required hospitals to be smoke-free; restrictions led some visitors to give smoking materials to patients without staff knowing.[49][13] In 1989, 12 residents died in a Norfolk, Virginia, nursing home fire attributed to such a gift.[50] For workplaces, the handbook calls a total smoking ban the best policy, with otherwise clearly signed smoking areas and noncombustible ashtrays with steep sides.[51]

Fire and life safety education has a limited role against this cause. Conventional educational techniques are of limited or unproven effectiveness for smoking fires, so a serious programme also considers laws requiring reduced-ignition-strength cigarettes.[52] Such laws are suggested at state level, because a single community cannot practically mandate them.
Limits of the data and common misconceptions
Smoking-material statistics carry hidden assumptions. In nonconfined US home fires, the item first ignited was unknown in 21 percent of the fires and 39 percent of the deaths, so the most severe fires are the least well documented.[53] Allocating unknowns in proportion to the known cases assumes that fires of unknown cause look like the others. Counts of fires and counts of deaths also tell different stories. In US one- and two-family dwellings, smoking materials ranked fifth by number of fires but first by deaths.[6] Child-playing and smoking fires are major contributors to deaths and injuries but minor contributors to incidents, so a programme that counts only incidents underrates this cause.[54]
Slow and small does not mean harmless or finished. A cigarette-initiated fire can produce lethal CO near the item within 10 minutes and can turn to flaming hours later.[33] Soaking or even immersing smouldering furniture in water may not put it out. Many victims have wetted a smouldering chair or sofa and gone to bed, only to face dense smoke or a full fire several hours later.[55]
Finally, the statistics quoted here are US data from around 2000. New US mattress rules of 2006 and fire-safe cigarette laws were expected to change the picture.[19][8] The 2008 handbook reported that smoking was more prevalent among European adults than North American adults, with smoking materials responsible for a higher share of fire deaths.[56]
See also
Notes
- ↑ Paoletti (2008), p. 20-66.
- ↑ 2.0 2.1 2.2 2.3 Babrauskas (2008b), p. 6-106.
- ↑ 3.0 3.1 Ahrens et al. (2008), p. 3-71.
- ↑ 4.0 4.1 Babrauskas (2008b), p. 6-118.
- ↑ 5.0 5.1 Ohlemiller (2002), p. 2-200.
- ↑ 6.0 6.1 6.2 Lathrop (2008b), p. 20-58.
- ↑ 7.0 7.1 7.2 Ahrens et al. (2008), p. 3-74.
- ↑ 8.0 8.1 8.2 8.3 8.4 Hall and Cote (2008), p. 3-14.
- ↑ 9.0 9.1 Gottuk (2008), p. 14-84.
- ↑ 10.0 10.1 Ministry of Business, Innovation and Employment (2025b), p. 42.
- ↑ 11.0 11.1 11.2 Australian Building Codes Board (2020b), pp. 77–78.
- ↑ Ahrens et al. (2008), pp. 3-70–3-71.
- ↑ 13.0 13.1 13.2 13.3 O'Connor (2008), p. 20-140.
- ↑ Ahrens et al. (2008), p. 3-77.
- ↑ Ahrens et al. (2008), p. 3-73.
- ↑ Ahrens et al. (2008), p. 3-72.
- ↑ Ahrens et al. (2008), p. 3-75.
- ↑ Lathrop (2008b), p. 20-57.
- ↑ 19.0 19.1 19.2 19.3 Babrauskas (2008b), p. 6-107.
- ↑ Hall and Cote (2008), p. 3-16.
- ↑ Berkol et al. (2008), p. 20-27.
- ↑ Hall (2008), p. 5-108.
- ↑ Babrauskas (2008b), p. 6-113.
- ↑ 24.0 24.1 Gamache (2008), p. 5-69.
- ↑ Van Rossum (2027), §4.1.
- ↑ Van Rossum (2027), §4.5.
- ↑ 27.0 27.1 Ohlemiller (2002), p. 2-207.
- ↑ Babrauskas (2008b), p. 6-103.
- ↑ Babrauskas (2008b), p. 6-124.
- ↑ 30.0 30.1 30.2 30.3 Ohlemiller (2002), p. 2-206.
- ↑ 31.0 31.1 31.2 Babrauskas (2008b), p. 6-109.
- ↑ 32.0 32.1 32.2 32.3 32.4 32.5 Purser (2002), p. 2-134.
- ↑ 33.0 33.1 Gann and Bryner (2008), p. 6-12.
- ↑ Babrauskas (2008b), p. 6-105.
- ↑ National Research Council of Canada et al. (2005), p. 1.2-9.
- ↑ Puchovsky and Hurley (2008), p. 3-172.
- ↑ National Research Council of Canada et al. (2005), p. 1.2-29.
- ↑ National Research Council of Canada et al. (2005), p. 1.4-5.
- ↑ Peacock and Reneke (2007), p. 2-4.
- ↑ Australian Building Codes Board (2020a), Data Sheet B2, p. 7.
- ↑ 41.0 41.1 Quintiere et al. (1985), as cited in National Research Council of Canada et al. (2005), p. 2.4-11.
- ↑ Australian Building Codes Board (2020a), Data Sheet B1, p. 9.
- ↑ Australian Building Codes Board (2020a), Data Sheet B1, pp. 9–10.
- ↑ 44.0 44.1 44.2 Babrauskas (2008b), p. 6-112.
- ↑ Ahrens et al. (2008), p. 3-90.
- ↑ Babrauskas (2008b), p. 6-111.
- ↑ Madrzykowski and Fleming (2008), p. 16-93.
- ↑ Kuligowski et al. (2005), p. 9.
- ↑ 49.0 49.1 O'Connor (2008), p. 20-152.
- ↑ O'Connor (2008), pp. 20-152–20-153.
- ↑ Mattern (2008b), p. 11-34.
- ↑ Hall (2008), p. 5-112.
- ↑ Ahrens et al. (2008), p. 3-76.
- ↑ Hall (2008), p. 5-105.
- ↑ Babrauskas (2008b), p. 6-110.
- ↑ Hall (2008), p. 5-107.
References
- Ahrens, M., Frazier, P., & Kelch, G. (2008). Use of fire incident data and statistics. In A. E. Cote, C. C. Grant, J. R. Hall Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 3-61–3-92). National Fire Protection Association.
- Australian Building Codes Board. (2020a). Data sheets: Fire Safety Verification Method (Handbook annex, Print version 1.1).
- Australian Building Codes Board. (2020b). Handbook: Fire Safety Verification Method (Print version 1.1).
- Babrauskas, V. (2008b). Upholstered furniture and mattresses. In A. E. Cote, C. C. Grant, J. R. Hall Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 6-103–6-128). National Fire Protection Association.
- Berkol, A., Briese, B., & Comeau, E. (2008). Hotels and university housing. In A. E. Cote, C. C. Grant, J. R. Hall Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 20-23–20-36). National Fire Protection Association.
- Gamache, S. (2008). Reaching high-risk groups. In A. E. Cote, C. C. Grant, J. R. Hall Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 5-63–5-85). National Fire Protection Association.
- Gann, R. G., & Bryner, N. P. (2008). Combustion products and their effects on life safety. In A. E. Cote, C. C. Grant, J. R. Hall Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 6-11–6-34). National Fire Protection Association.
- Gottuk, D. T. (2008). Household fire-warning equipment. In A. E. Cote, C. C. Grant, J. R. Hall Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 14-79–14-87). National Fire Protection Association.
- Hall, J. R., Jr. (2008). Using data for public education planning and decision making. In A. E. Cote, C. C. Grant, J. R. Hall Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 5-103–5-118). National Fire Protection Association.
- Hall, J. R., Jr., & Cote, A. E. (2008). An overview of the fire problem and fire protection. In A. E. Cote, C. C. Grant, J. R. Hall Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 3-3–3-30). National Fire Protection Association.
- Kuligowski, E. D., Evans, D. D., & Peacock, R. D. (2005). Post-construction fires prior to September 11, 2001 (NIST NCSTAR 1-4A). National Institute of Standards and Technology.
- Lathrop, J. K. (2008b). One- and two-family dwellings. In A. E. Cote, C. C. Grant, J. R. Hall Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 20-55–20-61). National Fire Protection Association.
- Madrzykowski, D., & Fleming, R. P. (2008). Residential sprinkler systems. In A. E. Cote, C. C. Grant, J. R. Hall Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 16-91–16-107). National Fire Protection Association.
- Mattern, L. J. (2008b). Housekeeping practices. In A. E. Cote, C. C. Grant, J. R. Hall Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 11-27–11-38). National Fire Protection Association.
- Ministry of Business, Innovation and Employment. (2025b). Verification Method C/VM2: Framework for fire safety design (2nd ed.).
- National Research Council of Canada, International Code Council, Department of Building and Housing, & Australian Building Codes Board. (2005). International fire engineering guidelines (2005 ed.). Australian Building Codes Board.
- O'Connor, D. J. (2008). Health care occupancies. In A. E. Cote, C. C. Grant, J. R. Hall Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 20-139–20-155). National Fire Protection Association.
- Ohlemiller, T. J. (2002). Smoldering combustion. In P. J. DiNenno, D. Drysdale, C. L. Beyler, W. D. Walton, R. L. P. Custer, J. R. Hall Jr., & J. M. Watts Jr. (Eds.), SFPE handbook of fire protection engineering (3rd ed., pp. 2-200–2-210). National Fire Protection Association; Society of Fire Protection Engineers.
- Paoletti, K. M. (2008). Manufactured housing. In A. E. Cote, C. C. Grant, J. R. Hall Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 20-63–20-71). National Fire Protection Association.
- Peacock, R., & Reneke, P. (2007). Verification and validation of selected fire models for nuclear power plant applications: Vol. 5. Consolidated Fire Growth and Smoke Transport Model (CFAST) (NUREG-1824; EPRI 1011999). U.S. Nuclear Regulatory Commission, Office of Nuclear Regulatory Research; Electric Power Research Institute.
- Puchovsky, M. T., & Hurley, M. J. (2008). Performance-Based codes and standards for fire safety. In A. E. Cote, C. C. Grant, J. R. Hall Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 3-167–3-181). National Fire Protection Association.
- Purser, D. A. (2002). Toxicity assessment of combustion products. In P. J. DiNenno, D. Drysdale, C. L. Beyler, W. D. Walton, R. L. P. Custer, J. R. Hall Jr., & J. M. Watts Jr. (Eds.), SFPE handbook of fire protection engineering (3rd ed., pp. 2-83–2-171). National Fire Protection Association; Society of Fire Protection Engineers.
- Van Rossum, E. (2027). Introduction to Fire Safety Engineering. Fire Safety Academy.