FSE wiki: fact-check corrections (written by Claude Opus 5.5) |
Add SVG figures fse-chemical-protective-clothing-v1.svg, fse-chemical-protective-clothing-v2.svg, fse-chemical-protective-clothing-v3.svg, fse-chemical-protective-clothing-v4.svg (list-8 visual plan) |
||
| (One intermediate revision by the same user not shown) | |||
| Line 1: | Line 1: | ||
'''Chemical protective clothing''' is apparel designed to protect the wearer's skin and eyes from contact with hazardous materials.<ref name="Wright-13-139">C. J. Wright (2008a), p. 13-139.</ref> It is used in [[Hazardous materials response]], where it forms part of the personal protective equipment together with respiratory protection.<ref name="Wright-13-139" /> There are two main types: vapour-protective suits, which are gastight and enclose the wearer together with the breathing apparatus, and liquid splash-protective suits, which keep out splashes but not vapours.<ref name="Teele-12-156">Teele (2008), p. 12-156.</ref><ref name="Teele-12-157">Teele (2008), p. 12-157.</ref> No material resists every chemical: a suit may protect against one chemical and yet be readily penetrated by another, and it offers little or no thermal protection in a fire.<ref name="Lawson-AppA">Lawson and Vettori (2005), Appendix A.</ref> | '''Chemical protective clothing''' is apparel designed to protect the wearer's skin and eyes from contact with hazardous materials.<ref name="Wright-13-139">C. J. Wright (2008a), p. 13-139.</ref> It is used in [[Hazardous materials response]], where it forms part of the personal protective equipment together with respiratory protection.<ref name="Wright-13-139" /> There are two main types: vapour-protective suits, which are gastight and enclose the wearer together with the breathing apparatus, and liquid splash-protective suits, which keep out splashes but not vapours.<ref name="Teele-12-156">Teele (2008), p. 12-156.</ref><ref name="Teele-12-157">Teele (2008), p. 12-157.</ref> No material resists every chemical: a suit may protect against one chemical and yet be readily penetrated by another, and it offers little or no thermal protection in a fire.<ref name="Lawson-AppA">Lawson and Vettori (2005), Appendix A.</ref> | ||
[[File:fse-chemical-protective-clothing-v5.jpg|thumb|upright=1.5|alt=Two hazardous materials technicians in fully encapsulating gastight suits with large visors during an exercise|Hazardous materials technicians in fully encapsulating vapour-protective suits, with the breathing apparatus worn inside the suit.]] | |||
In the United States, as described in the 2008 ''Fire Protection Handbook'', suits were certified to NFPA 1991 or NFPA 1992, and ensembles for terrorism incidents to NFPA 1994.<ref name="Teele-12-157" /><ref name="Teele-12-158">Teele (2008), p. 12-158.</ref> Responders also used the four levels of protection, A to D, defined by the US Environmental Protection Agency (EPA).<ref name="Teele-12-156" /> Wearing the clothing can cause heat stress and limit vision, mobility and communication.<ref name="Wright-13-140">C. J. Wright (2008a), p. 13-140.</ref> | In the United States, as described in the 2008 ''Fire Protection Handbook'', suits were certified to NFPA 1991 or NFPA 1992, and ensembles for terrorism incidents to NFPA 1994.<ref name="Teele-12-157" /><ref name="Teele-12-158">Teele (2008), p. 12-158.</ref> Responders also used the four levels of protection, A to D, defined by the US Environmental Protection Agency (EPA).<ref name="Teele-12-156" /> Wearing the clothing can cause heat stress and limit vision, mobility and communication.<ref name="Wright-13-140">C. J. Wright (2008a), p. 13-140.</ref> | ||
| Line 7: | Line 9: | ||
A chemical can defeat a protective garment in three ways. Penetration is the movement of a chemical through zippers, stitched seams or imperfections such as pinholes. Permeation is the process by which the chemical dissolves in the material and moves through it on a molecular level. Degradation is the physical decomposition of the material through chemicals, use or ambient conditions such as sunlight.<ref name="Wright-13-139" /> Permeation often happens without any visible sign of chemical attack.<ref name="Teele-12-157" /> The breakthrough time is the time a hazardous material takes to move through the protective material.<ref name="Wright-13-139" /> | A chemical can defeat a protective garment in three ways. Penetration is the movement of a chemical through zippers, stitched seams or imperfections such as pinholes. Permeation is the process by which the chemical dissolves in the material and moves through it on a molecular level. Degradation is the physical decomposition of the material through chemicals, use or ambient conditions such as sunlight.<ref name="Wright-13-139" /> Permeation often happens without any visible sign of chemical attack.<ref name="Teele-12-157" /> The breakthrough time is the time a hazardous material takes to move through the protective material.<ref name="Wright-13-139" /> | ||
[[File:fse-chemical-protective-clothing-v1.svg|thumb|upright=1.5|alt=Three panels of a suit wall: chemical passing a seam or pinhole, molecules diffusing through intact material, and material breaking down|Penetration, permeation and degradation of chemical protective clothing. Penetration passes zippers, seams and pinholes; permeation is molecular movement through the material, often without visible attack; degradation is physical decomposition of the material.]] | |||
Resistance has to be known for each combination of chemical and material. For ensembles certified to NFPA 1991 or NFPA 1992, manufacturers had to supply technical data packages. Makers of vapour-protective ensembles provide permeation data, and makers of splash-protective garments provide penetration data.<ref name="Teele-12-157" /> Permeation data should name the chemical and give the breakthrough time, the permeation rate and the system sensitivity, which allows results from different laboratories to be compared.<ref name="Teele-12-157" /> Data should cover every primary material in the ensemble, including suit, hood, visor, gloves and boots. Materials that show no breakthrough or penetration for a large number of chemicals are likely to have a broad range of resistance.<ref name="Teele-12-157" /> | Resistance has to be known for each combination of chemical and material. For ensembles certified to NFPA 1991 or NFPA 1992, manufacturers had to supply technical data packages. Makers of vapour-protective ensembles provide permeation data, and makers of splash-protective garments provide penetration data.<ref name="Teele-12-157" /> Permeation data should name the chemical and give the breakthrough time, the permeation rate and the system sensitivity, which allows results from different laboratories to be compared.<ref name="Teele-12-157" /> Data should cover every primary material in the ensemble, including suit, hood, visor, gloves and boots. Materials that show no breakthrough or penetration for a large number of chemicals are likely to have a broad range of resistance.<ref name="Teele-12-157" /> | ||
| Line 18: | Line 21: | ||
Liquid splash-protective ensembles under NFPA 1992 protect against liquid chemicals in the form of splashes. They do not protect against continuous liquid contact or against chemical vapours and gases.<ref name="Teele-12-157" /> A material that stops liquid penetration can still let a chemical permeate. Such clothing is not gastight, even if duct tape is used to seal its interfaces. It is meant only for liquids with a low vapour pressure and no known skin absorption toxicity, and it may not be used against known or suspected carcinogens.<ref name="Teele-12-157" /> NFPA 1992 allowed the SCBA inside or outside the suit, although wearing it inside was strongly recommended to prevent its failure and to reduce decontamination problems.<ref name="Teele-12-157" /> | Liquid splash-protective ensembles under NFPA 1992 protect against liquid chemicals in the form of splashes. They do not protect against continuous liquid contact or against chemical vapours and gases.<ref name="Teele-12-157" /> A material that stops liquid penetration can still let a chemical permeate. Such clothing is not gastight, even if duct tape is used to seal its interfaces. It is meant only for liquids with a low vapour pressure and no known skin absorption toxicity, and it may not be used against known or suspected carcinogens.<ref name="Teele-12-157" /> NFPA 1992 allowed the SCBA inside or outside the suit, although wearing it inside was strongly recommended to prevent its failure and to reduce decontamination problems.<ref name="Teele-12-157" /> | ||
[[File:fse-chemical-protective-clothing-v2.svg|thumb|upright=1.5|alt=Two suit outlines: an encapsulating vapour-protective suit with SCBA inside, and a splash suit with separate gloves and boots|Vapour-protective ensemble (NFPA 1991, gastight, SCBA inside) and liquid splash-protective ensemble (NFPA 1992, not gastight, SCBA inside or outside, inside strongly recommended).]] | |||
A third family covers terrorism incidents. NFPA 1994 (second edition, 2007) specified Class 2, Class 3 and Class 4 ensembles. Classes 2 and 3 are tested for permeation by chemical warfare agents and liquid industrial chemicals at lower exposure rates matching their intended protection level. Class 4 protects against particulates, for example at "white powder" incidents.<ref name="Teele-12-158" /> The former Class 1, the highest level of protection against vapour and liquid hazards [[Immediately dangerous to life or health|immediately dangerous to life and health]], was moved to NFPA 1991.<ref name="Teele-12-158" /> Teele (2008) describes NFPA 1994 ensembles as intended to be kept pristine in their own packaging until use and discarded after a single exposure.<ref name="Teele-12-158" /> | A third family covers terrorism incidents. NFPA 1994 (second edition, 2007) specified Class 2, Class 3 and Class 4 ensembles. Classes 2 and 3 are tested for permeation by chemical warfare agents and liquid industrial chemicals at lower exposure rates matching their intended protection level. Class 4 protects against particulates, for example at "white powder" incidents.<ref name="Teele-12-158" /> The former Class 1, the highest level of protection against vapour and liquid hazards [[Immediately dangerous to life or health|immediately dangerous to life and health]], was moved to NFPA 1991.<ref name="Teele-12-158" /> Teele (2008) describes NFPA 1994 ensembles as intended to be kept pristine in their own packaging until use and discarded after a single exposure.<ref name="Teele-12-158" /> | ||
| Line 51: | Line 55: | ||
The levels have clear limits. The EPA defined them primarily for workers at hazardous waste sites, where emergency conditions do not usually exist. According to Teele (2008), emergency responders commonly, and often inappropriately, use them.<ref name="Teele-12-156" /> The levels may serve as a starting point for selecting an ensemble, but each ensemble must suit the specific situation. Having the right components is not enough, because the EPA levels do not define what performance the clothing must offer.<ref name="Teele-12-156" /> | The levels have clear limits. The EPA defined them primarily for workers at hazardous waste sites, where emergency conditions do not usually exist. According to Teele (2008), emergency responders commonly, and often inappropriately, use them.<ref name="Teele-12-156" /> The levels may serve as a starting point for selecting an ensemble, but each ensemble must suit the specific situation. Having the right components is not enough, because the EPA levels do not define what performance the clothing must offer.<ref name="Teele-12-156" /> | ||
[[File:fse-chemical-protective-clothing-v3.svg|thumb|upright=1.5|alt=Four-step ladder of EPA protection levels A to D with the condition for using each level|The four EPA levels of protection, defined primarily for hazardous waste sites and often used by emergency responders as a starting point only.]] | |||
The New York City Fire Department (FDNY) used the same four levels in its hazardous materials response plan of 1994. That plan described Level B as giving high respiratory protection but less skin protection than Level A. Level C presupposed that the air contaminants were identified, their concentrations measured and the atmosphere not deficient in oxygen. Level D guarded against nuisance contamination only.<ref name="Lawson-AppA" /> Levels A and B were available only to members of the department's Hazardous Materials Unit. Turnout or bunker gear was not classified as chemical protective clothing; the highest level of chemical protection it could give was Level D.<ref name="Lawson-AppA" /> | The New York City Fire Department (FDNY) used the same four levels in its hazardous materials response plan of 1994. That plan described Level B as giving high respiratory protection but less skin protection than Level A. Level C presupposed that the air contaminants were identified, their concentrations measured and the atmosphere not deficient in oxygen. Level D guarded against nuisance contamination only.<ref name="Lawson-AppA" /> Levels A and B were available only to members of the department's Hazardous Materials Unit. Turnout or bunker gear was not classified as chemical protective clothing; the highest level of chemical protection it could give was Level D.<ref name="Lawson-AppA" /> | ||
| Line 73: | Line 78: | ||
Work in suits is organised by zones and teams. The hot zone surrounds the incident, decontamination takes place in the warm zone, and the command post stands in the cold zone. Access to each zone depends on need and on the level of personal protection set in the plan of action.<ref name="Wright-13-142">C. J. Wright (2008a), p. 13-142.</ref><ref name="Wright-13-143">C. J. Wright (2008a), p. 13-143.</ref> In the FDNY plan, a backup team of at least two members maintained sight contact with the entry team whenever possible. It stood by in proper protective equipment in a safe area, ready to rescue them.<ref name="Lawson-AppA" /> | Work in suits is organised by zones and teams. The hot zone surrounds the incident, decontamination takes place in the warm zone, and the command post stands in the cold zone. Access to each zone depends on need and on the level of personal protection set in the plan of action.<ref name="Wright-13-142">C. J. Wright (2008a), p. 13-142.</ref><ref name="Wright-13-143">C. J. Wright (2008a), p. 13-143.</ref> In the FDNY plan, a backup team of at least two members maintained sight contact with the entry team whenever possible. It stood by in proper protective equipment in a safe area, ready to rescue them.<ref name="Lawson-AppA" /> | ||
[[File:fse-chemical-protective-clothing-v4.svg|thumb|upright=1.5|alt=Plan of concentric hot, warm and cold zones with decontamination corridor, access control points and command post upwind|Control zones at a hazardous materials incident: the suited entry team in the hot zone and a backup team standing by in a safe area, with decontamination in the warm zone and the command post in the cold zone.]] | |||
In the same plan, a support member monitored SCBA use time during suit operations and checked the compatibility of the equipment with the hazardous material. Serial numbers of the chemical protective suits worn by members were documented.<ref name="Lawson-AppA" /> Communication inside a suit needs special equipment. Merklinger (2008) notes that many hazardous materials team members must work inside encapsulating suits. They need communications systems designed for this, preferably hands-free two-way wireless systems with bone, ear or throat microphones.<ref name="Merklinger-12-259">Merklinger (2008), p. 12-259.</ref> Response personnel should also be able to record the use, repair and testing of their chemical protective clothing.<ref name="Wright-13-143" /> | In the same plan, a support member monitored SCBA use time during suit operations and checked the compatibility of the equipment with the hazardous material. Serial numbers of the chemical protective suits worn by members were documented.<ref name="Lawson-AppA" /> Communication inside a suit needs special equipment. Merklinger (2008) notes that many hazardous materials team members must work inside encapsulating suits. They need communications systems designed for this, preferably hands-free two-way wireless systems with bone, ear or throat microphones.<ref name="Merklinger-12-259">Merklinger (2008), p. 12-259.</ref> Response personnel should also be able to record the use, repair and testing of their chemical protective clothing.<ref name="Wright-13-143" /> | ||
Latest revision as of 18:54, 14 November 2026
Chemical protective clothing is apparel designed to protect the wearer's skin and eyes from contact with hazardous materials.[1] It is used in Hazardous materials response, where it forms part of the personal protective equipment together with respiratory protection.[1] There are two main types: vapour-protective suits, which are gastight and enclose the wearer together with the breathing apparatus, and liquid splash-protective suits, which keep out splashes but not vapours.[2][3] No material resists every chemical: a suit may protect against one chemical and yet be readily penetrated by another, and it offers little or no thermal protection in a fire.[4]

In the United States, as described in the 2008 Fire Protection Handbook, suits were certified to NFPA 1991 or NFPA 1992, and ensembles for terrorism incidents to NFPA 1994.[3][5] Responders also used the four levels of protection, A to D, defined by the US Environmental Protection Agency (EPA).[2] Wearing the clothing can cause heat stress and limit vision, mobility and communication.[6]
How chemicals pass through protective materials
At a hazardous materials incident, personal protective equipment consists of protective clothing and respiratory protection. It is used to shield or isolate a person from the chemical, biological, physical or thermal hazards that may be present.[1] C. J. Wright (2008a) stresses that no single combination of equipment protects against all hazards. It must be combined with other measures such as medical monitoring and environmental surveillance, and both overprotection and underprotection can be hazardous.[1]
A chemical can defeat a protective garment in three ways. Penetration is the movement of a chemical through zippers, stitched seams or imperfections such as pinholes. Permeation is the process by which the chemical dissolves in the material and moves through it on a molecular level. Degradation is the physical decomposition of the material through chemicals, use or ambient conditions such as sunlight.[1] Permeation often happens without any visible sign of chemical attack.[3] The breakthrough time is the time a hazardous material takes to move through the protective material.[1]
Resistance has to be known for each combination of chemical and material. For ensembles certified to NFPA 1991 or NFPA 1992, manufacturers had to supply technical data packages. Makers of vapour-protective ensembles provide permeation data, and makers of splash-protective garments provide penetration data.[3] Permeation data should name the chemical and give the breakthrough time, the permeation rate and the system sensitivity, which allows results from different laboratories to be compared.[3] Data should cover every primary material in the ensemble, including suit, hood, visor, gloves and boots. Materials that show no breakthrough or penetration for a large number of chemicals are likely to have a broad range of resistance.[3]
When selecting materials, C. J. Wright (2008a) advises looking for breakthrough times of at least 2 hours. A breakthrough time of 2 hours represents the normal physical limit of a responder's capacity for effective work in protective equipment.[6] His worksheet for recording compatible materials sorts them into breakthrough times of more than 8 hours, more than 2 hours and less than half an hour. Several materials can be layered to give the required protection.[6] Where a jurisdiction has specific chemicals that have not been tested, Teele (2008) recommends asking the manufacturer for test data on those chemicals.[3]
Types of suits and ensembles
For emergency response, Teele (2008) names only two acceptable designs. The first is the fully or totally encapsulating suit. The second is the nonencapsulating or "splash" suit worn with accessory items such as chemically resistant gloves and boots.[2] These descriptions concern design only and say nothing about performance. Hazardous materials ensembles should cover both the wearer and the wearer's respiratory protection completely, because a self-contained breathing apparatus (SCBA) worn outside the ensemble is exposed to the contaminated environment.[2][3]
Vapour-protective ensembles under NFPA 1991 are designed to be "gastight" and "liquidtight". They are intended for situations where no chemical contact is permissible or where the exposure is unknown.[3] They had to resist permeation by the hazardous materials present, and NFPA 1991 required the SCBA to be worn inside the suit.[3] By 2007 these ensembles also carried the mandatory requirements for protection at chemical, biological, radiological and nuclear (CBRN) terrorism incidents where no contact is permissible. Those requirements had earlier been covered as the Class 1 ensemble of the 2001 edition of NFPA 1994.[3]
Liquid splash-protective ensembles under NFPA 1992 protect against liquid chemicals in the form of splashes. They do not protect against continuous liquid contact or against chemical vapours and gases.[3] A material that stops liquid penetration can still let a chemical permeate. Such clothing is not gastight, even if duct tape is used to seal its interfaces. It is meant only for liquids with a low vapour pressure and no known skin absorption toxicity, and it may not be used against known or suspected carcinogens.[3] NFPA 1992 allowed the SCBA inside or outside the suit, although wearing it inside was strongly recommended to prevent its failure and to reduce decontamination problems.[3]
A third family covers terrorism incidents. NFPA 1994 (second edition, 2007) specified Class 2, Class 3 and Class 4 ensembles. Classes 2 and 3 are tested for permeation by chemical warfare agents and liquid industrial chemicals at lower exposure rates matching their intended protection level. Class 4 protects against particulates, for example at "white powder" incidents.[5] The former Class 1, the highest level of protection against vapour and liquid hazards immediately dangerous to life and health, was moved to NFPA 1991.[5] Teele (2008) describes NFPA 1994 ensembles as intended to be kept pristine in their own packaging until use and discarded after a single exposure.[5]
| Standard | Design | Protects against | Main test criterion | Breathing apparatus |
|---|---|---|---|---|
| NFPA 1991 | Vapour-protective, gastight and liquidtight | Vapours, gases and liquids where no contact is permissible or exposure is unknown | Breakthrough time of at least 1 h for each test chemical | Inside the suit (required) |
| NFPA 1992 | Liquid splash-protective, not gastight | Liquid splashes of low-vapour-pressure chemicals without known skin absorption toxicity | Penetration resistance time of at least 1 h for each test liquid | Inside or outside (inside strongly recommended) |
| NFPA 1994, Classes 2 and 3 | CBRN terrorism ensembles | Chemical warfare agents and liquid industrial chemicals at lower exposure rates | Permeation resistance at class-specific exposure rates | Certified with a specific NIOSH CBRN respirator |
| NFPA 1994, Class 4 | CBRN terrorism ensemble | Particulates | Particulate inward leakage | Certified with a specific NIOSH CBRN respirator |
Levels of protection
The EPA defined four levels of protection, A to D, which combine protective clothing and respiratory protection.[2] As described by C. J. Wright (2008a), Level A is the highest and should be worn when respiratory, skin, eye and mucous membrane protection is needed.[1] Level B gives a lesser degree of skin and eye protection and is the minimum recommended for initial site entries until the hazards have been determined.[6] Level C may be worn only when the airborne substance is known, its concentration measured, the criteria for air-purifying respirators met and skin and eye exposure unlikely. Level D is primarily a work uniform and should not be worn where respiratory or skin hazards exist.[6]
| Level | Protection | When it may be worn |
|---|---|---|
| A | Highest level | When respiratory, skin, eye and mucous membrane protection is needed |
| B | Second highest; lesser skin and eye protection | Minimum for initial site entries until hazards have been determined |
| C | Third highest | Airborne substance known, concentration measured, air-purifying respirator criteria met, skin and eye exposure unlikely; periodic air monitoring |
| D | Lowest; primarily a work uniform | Not on any site where respiratory or skin hazards exist |
The levels have clear limits. The EPA defined them primarily for workers at hazardous waste sites, where emergency conditions do not usually exist. According to Teele (2008), emergency responders commonly, and often inappropriately, use them.[2] The levels may serve as a starting point for selecting an ensemble, but each ensemble must suit the specific situation. Having the right components is not enough, because the EPA levels do not define what performance the clothing must offer.[2]
The New York City Fire Department (FDNY) used the same four levels in its hazardous materials response plan of 1994. That plan described Level B as giving high respiratory protection but less skin protection than Level A. Level C presupposed that the air contaminants were identified, their concentrations measured and the atmosphere not deficient in oxygen. Level D guarded against nuisance contamination only.[4] Levels A and B were available only to members of the department's Hazardous Materials Unit. Turnout or bunker gear was not classified as chemical protective clothing; the highest level of chemical protection it could give was Level D.[4]
Standards and performance testing
In the United States, both product standards for hazardous materials clothing set test batteries of chemicals that represent the classes met at hazardous materials emergencies.[3] For vapour-protective ensembles under NFPA 1991, permeation resistance is measured as a breakthrough time of at least 1 hour. This must be met for each chemical in ASTM F1001, the standard guide for selecting chemicals to evaluate protective clothing materials.[3] Any further chemicals or mixtures for which the manufacturer certifies the ensemble must meet the same criterion. Further tests cover gastight and liquidtight integrity, overall suit function, the suit ventilation rate and physical durability.[3]
For splash-protective clothing under NFPA 1992, the criterion is a penetration resistance time of at least 1 hour for each liquid in the battery. Additional tests check liquidtight integrity, overall function and durability.[3] The CBRN ensembles of NFPA 1994 are further tested for inward leakage through exhaust valves, burst strength, puncture propagation, seam and closure strength, visual acuity through the visor, suit airflow and cold weather performance.[5] Every Class 2, 3 or 4 ensemble must be certified together with a specific respirator certified by the National Institute for Occupational Safety and Health (NIOSH) for CBRN use.[5]
The manufacturer's technical data package should document all features of the ensemble and the materials used in it. It should state specific limitations and restrictions on use. At a minimum, it should give procedures for donning and doffing, inspection, maintenance, storage, decontamination and use.[3] At NFPA, these standards were the responsibility of the Technical Committee on Hazardous Materials Protective Clothing and Equipment. Its scope covered protective clothing and equipment for emergency responders at hazardous materials incidents, excluding respiratory protection.[7]
The regulatory basis was the rule 29 CFR 1910.120 on hazardous materials emergency response of the US Occupational Safety and Health Administration (OSHA).[8] The US Congress had the EPA issue an identical rule, 40 CFR 311 of 23 June 1989, so that the requirements also covered state and local government employees and volunteers.[9] Under 29 CFR 1910.120, positive-pressure SCBA was the minimum respiratory protection at hazardous materials emergencies until concentrations had been determined.[1]
Selection and use at incidents
C. J. Wright (2008a) sets out a stepwise selection procedure. First, the name, concentration and hazards of each material are determined. The types of exposure expected for each response option are then predicted: immersion, splash or airborne contact.[1] If liquid contact is the chief threat, the clothing should resist degradation and penetration. A vapour threat may require airtight, impermeable clothing.[1]
Chemically compatible materials are then identified and matched with the equipment available. The buddy system, backup personnel and enough equipment in the right sizes must also be considered.[6] C. J. Wright (2008a) stresses that pre-emergency planning cannot be overemphasised in this selection.[10]
Training determines who may wear what. Under OSHA rule 29 CFR 1910.120(q)(6), responders at the operations level, which includes most fire suppression personnel, need at least 8 hours of training or sufficient experience to demonstrate the required competencies. They must know how to select and use the protective equipment available at that level.[11] Hazardous materials technicians, who approach a release to plug or patch it, need at least 24 hours of training. Technicians and specialists must be able to select and use the specialised chemical protective clothing provided to them.[12][13]
An incident commander at such an incident must understand the hazards and risks of working in chemical protective clothing.[13] The FDNY plan of 1994 drew the same line. Its operations-level first responders were not trained or equipped for specialised chemical protective clothing, so their actions were limited to what could be done in SCBA and Structural firefighting protective clothing.[4]
Work in suits is organised by zones and teams. The hot zone surrounds the incident, decontamination takes place in the warm zone, and the command post stands in the cold zone. Access to each zone depends on need and on the level of personal protection set in the plan of action.[14][15] In the FDNY plan, a backup team of at least two members maintained sight contact with the entry team whenever possible. It stood by in proper protective equipment in a safe area, ready to rescue them.[4]
In the same plan, a support member monitored SCBA use time during suit operations and checked the compatibility of the equipment with the hazardous material. Serial numbers of the chemical protective suits worn by members were documented.[4] Communication inside a suit needs special equipment. Merklinger (2008) notes that many hazardous materials team members must work inside encapsulating suits. They need communications systems designed for this, preferably hands-free two-way wireless systems with bone, ear or throat microphones.[16] Response personnel should also be able to record the use, repair and testing of their chemical protective clothing.[15]
Under the FDNY plan, everything leaving the hot zone should be treated as contaminated unless shown otherwise, and appropriate Decontamination procedures should be applied to personnel and equipment.[4] Decontamination is the removal or neutralisation of contaminants from personnel and equipment.[6] Planning should identify how clothing and equipment that cannot be decontaminated will be isolated, secured and disposed of.[17] Teele (2008) notes that decontamination may not be possible when garments are contaminated with chemical, radiological or biological agents. Such garments should then be discarded in accordance with local, state and federal regulations.[18]
Limitations
Protection is always limited in scope. According to the FDNY plan of 1994, a suit may protect against only one chemical yet be readily penetrated by others for which it was not designed. No single suit protects against all hazardous materials.[4] Chemical protective clothing also offers little or no thermal protection in case of fire.[4]
Structural fire-fighting clothing has the opposite profile. It is designed against heat and flame, and is worn with SCBA against the toxic products of fire smoke.[4] Even when certified, however, it gives little or no protection against hazardous materials.[2]
The clothing itself can create hazards. C. J. Wright (2008a) lists heat stress, physical and psychological stress, and impaired vision, mobility and communication.[6] Response personnel should be able to identify the symptoms of heat and cold stress. They should also be aware of the physical and psychological stresses that can affect users of protective equipment.[15] Even the 2-hour breakthrough time recommended for materials is tied to the wearer, as it represents the normal physical limit of effective work in protective equipment.[6]
Ordinary emergency clothing is no substitute at terrorism incidents. Teele (2008) warns that existing fire-fighting, emergency medical or hazardous materials clothing might give some low level of skin protection for a very short exposure. No evaluation or procedure exists to determine how much protection each item in service would offer.[5] In-service clothing that is not certified for CBRN protection most likely gives no protection at all, or only a few seconds before the wearer could face severe or lethal exposure.[5]
Selection rests on knowing the hazard. The EPA levels and the encapsulating or splash designs describe configuration, not performance.[2] The choice of an NFPA 1994 class must be based on a thorough risk assessment of the incident. This assessment considers the exposure and delivery method, the potential for skin contact, the identity and concentration of the contaminant, its persistency and the threat of contamination and cross-contamination.[5] Where the appropriate level of protection is not available, C. J. Wright (2008a) advises obtaining it from other resources.[6]
See also
- Emergency Response Guidebook
- Weapons of mass destruction
- Incident safety officer
- Firefighter rehabilitation
Notes
- ↑ 1.00 1.01 1.02 1.03 1.04 1.05 1.06 1.07 1.08 1.09 1.10 C. J. Wright (2008a), p. 13-139.
- ↑ 2.0 2.1 2.2 2.3 2.4 2.5 2.6 2.7 2.8 Teele (2008), p. 12-156.
- ↑ 3.00 3.01 3.02 3.03 3.04 3.05 3.06 3.07 3.08 3.09 3.10 3.11 3.12 3.13 3.14 3.15 3.16 3.17 3.18 3.19 Teele (2008), p. 12-157.
- ↑ 4.00 4.01 4.02 4.03 4.04 4.05 4.06 4.07 4.08 4.09 Lawson and Vettori (2005), Appendix A.
- ↑ 5.00 5.01 5.02 5.03 5.04 5.05 5.06 5.07 5.08 5.09 Teele (2008), p. 12-158.
- ↑ 6.00 6.01 6.02 6.03 6.04 6.05 6.06 6.07 6.08 6.09 6.10 C. J. Wright (2008a), p. 13-140.
- ↑ Hildebrand and Noll (2008), p. 13-96.
- ↑ Teele (2008), p. 12-144.
- ↑ Teele (2008), p. 12-145.
- ↑ C. J. Wright (2008a), p. 13-138.
- ↑ Hildebrand and Noll (2008), pp. 13-88–13-89.
- ↑ Hildebrand and Noll (2008), p. 13-89.
- ↑ 13.0 13.1 Hildebrand and Noll (2008), p. 13-90.
- ↑ C. J. Wright (2008a), p. 13-142.
- ↑ 15.0 15.1 15.2 C. J. Wright (2008a), p. 13-143.
- ↑ Merklinger (2008), p. 12-259.
- ↑ C. J. Wright (2008a), p. 13-141.
- ↑ Teele (2008), p. 12-146.
References
- Hildebrand, M. S., & Noll, G. G. (2008). Public fire protection and hazmat management. In A. E. Cote, C. C. Grant, J. R. Hall, Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 13-81–13-98). National Fire Protection Association.
- Lawson, J. R., & Vettori, R. L. (2005). The emergency response operations (NIST NCSTAR 1-8). National Institute of Standards and Technology.
- Merklinger, J. M. (2008). Public emergency services alarm, dispatch, and communications systems. In A. E. Cote, C. C. Grant, J. R. Hall, Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 12-253–12-266). National Fire Protection Association.
- Teele, B. W. (2008). Fire and emergency services protective clothing and protective equipment. In A. E. Cote, C. C. Grant, J. R. Hall, Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 12-143–12-160). National Fire Protection Association.
- Wright, C. J. (2008a). Managing the response to hazardous material incidents. In A. E. Cote, C. C. Grant, J. R. Hall, Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 13-117–13-144). National Fire Protection Association.