== Physiology of heat, exertion and smoke ==
== Physiology of heat, exertion and smoke ==
Purser (2002) describes how prolonged heat exposure that is too mild to burn still harms the body. In air below about 120 °C (dry) or 80 °C (saturated), the main effect is a gradual rise of body core temperature. A rise from the normal 37 °C to about 39 °C is within the physiological range and can occur during hard exercise. At 40 °C consciousness becomes blurred and the person becomes seriously ill, and above 42.5 °C the condition is fatal unless treated within minutes.<ref name="Purser-2-125">Purser (2002), p. 2-125.</ref>
Purser (2002) describes how prolonged heat exposure that is too mild to burn still harms the body. In air below about 120 °C (dry) or 80 °C (saturated), the main effect is a gradual rise of body core temperature. A rise from the normal 37 °C to about 39 °C is within the physiological range and can occur during hard exercise. At 40 °C consciousness becomes blurred and the person becomes seriously ill, and above 42.5 °C the condition is fatal unless treated within minutes.<ref name="Purser-2-125">Purser (2002), p. 2-125.</ref>
[[File:fse-firefighter-rehabilitation-v3.svg|thumb|upright=1.5|alt=Vertical thermometer scale from 36 to 44 degrees Celsius with bands for normal, hard exercise, seriously ill and fatal|Body core temperature bands from normal to fatal hyperthermia.]]


Below about 120 °C, evaporation of sweat is an important means of cooling. Clothing can then shorten the tolerance time by impeding that evaporative cooling, and a fire fighter may suffer heat stroke after an exposure longer than 15 minutes, especially in humid air and during hard work.<ref name="Purser-2-125-126">Purser (2002), pp. 2-125–2-126.</ref> The general mechanisms are treated in [[Effects of heat on people]].
Below about 120 °C, evaporation of sweat is an important means of cooling. Clothing can then shorten the tolerance time by impeding that evaporative cooling, and a fire fighter may suffer heat stroke after an exposure longer than 15 minutes, especially in humid air and during hard work.<ref name="Purser-2-125-126">Purser (2002), pp. 2-125–2-126.</ref> The general mechanisms are treated in [[Effects of heat on people]].
Line 31: Line 32:


Exertion also changes the effect of smoke. Purser (2002) explains that the uptake of [[carbon monoxide]] depends on the respiratory minute volume, and hence on the activity of the person. Active subjects are seriously affected at carboxyhaemoglobin levels that have only minor effects on sedentary ones.<ref name="Purser-2-101">Purser (2002), p. 2-101.</ref> In Purser's model for a 70 kg person, incapacitation is expected at about 40 percent carboxyhaemoglobin at rest, 30 percent during light work and 20 percent during heavy work. The corresponding breathing rates are 8.5, 25 and 50 L/min.<ref name="Purser-2-102">Purser (2002), p. 2-102.</ref> Teele (2008) notes that the particulate respirators used by some wildland fire fighters do nothing to protect against carbon monoxide.<ref name="Teele-12-154" />
Exertion also changes the effect of smoke. Purser (2002) explains that the uptake of [[carbon monoxide]] depends on the respiratory minute volume, and hence on the activity of the person. Active subjects are seriously affected at carboxyhaemoglobin levels that have only minor effects on sedentary ones.<ref name="Purser-2-101">Purser (2002), p. 2-101.</ref> In Purser's model for a 70 kg person, incapacitation is expected at about 40 percent carboxyhaemoglobin at rest, 30 percent during light work and 20 percent during heavy work. The corresponding breathing rates are 8.5, 25 and 50 L/min.<ref name="Purser-2-102">Purser (2002), p. 2-102.</ref> Teele (2008) notes that the particulate respirators used by some wildland fire fighters do nothing to protect against carbon monoxide.<ref name="Teele-12-154" />
[[File:fse-firefighter-rehabilitation-v4.svg|thumb|upright=1.5|alt=Bar chart with three bars for rest, light work and heavy work showing incapacitating carboxyhaemoglobin falling from 40 to 20 percent|Carboxyhaemoglobin level at which incapacitation is expected for a 70 kg person at rest, in light work and in heavy work, with breathing rates.]]


== Organisation at the incident ==
== Organisation at the incident ==
Line 38: Line 40:


The rehabilitation area is organised as a group or division within the incident management system. It is placed in a safe environment away from the hazardous area of the incident. Its resources include an environment that limits temperature stress, medical equipment and adequate medical staff.<ref name="Loflin-12-124" />
The rehabilitation area is organised as a group or division within the incident management system. It is placed in a safe environment away from the hazardous area of the incident. Its resources include an environment that limits temperature stress, medical equipment and adequate medical staff.<ref name="Loflin-12-124" />
[[File:fse-firefighter-rehabilitation-v1.svg|thumb|upright=1.5|alt=Plan of an incident with the burning building and hazard zone on one side and a rehabilitation area with medical, rest and fluids zones on the other|Example layout of an incident scene rehabilitation area away from the hazardous area, with medical care, rest and climate relief, and food and fluids.]]


The FDNY procedure adds practical site criteria. The incident commander designates the location and may appoint a RAC officer, who can be a chief officer at large operations. The site must protect from the weather, be free of exhaust fumes, apparatus and equipment, give room for members to take off their bunker gear and be easily accessible to emergency medical services.<ref name="LV-A-RAC" /> Enclosed rescue vehicles can serve as a sheltered environment for rehabilitation during inclement weather.<ref name="Tutterow-12-278">Tutterow (2008), p. 12-278.</ref>
The FDNY procedure adds practical site criteria. The incident commander designates the location and may appoint a RAC officer, who can be a chief officer at large operations. The site must protect from the weather, be free of exhaust fumes, apparatus and equipment, give room for members to take off their bunker gear and be easily accessible to emergency medical services.<ref name="LV-A-RAC" /> Enclosed rescue vehicles can serve as a sheltered environment for rehabilitation during inclement weather.<ref name="Tutterow-12-278">Tutterow (2008), p. 12-278.</ref>
Line 45: Line 48:
== Medical evaluation and care ==
== Medical evaluation and care ==
Medical care is one of the main elements of rehabilitation. Evaluation and treatment in the rehabilitation area follow emergency medical service protocols that the department develops with the fire department physician and the EMS medical director. If advanced life support (paramedic) personnel are available, that level of care is preferred. The minimum is basic life support. During long-duration or heavy-exertion operations, assigning an ambulance or other support crew to rehabilitation is essential, and advanced life support must be available quickly.<ref name="Loflin-12-124" />
Medical care is one of the main elements of rehabilitation. Evaluation and treatment in the rehabilitation area follow emergency medical service protocols that the department develops with the fire department physician and the EMS medical director. If advanced life support (paramedic) personnel are available, that level of care is preferred. The minimum is basic life support. During long-duration or heavy-exertion operations, assigning an ambulance or other support crew to rehabilitation is essential, and advanced life support must be available quickly.<ref name="Loflin-12-124" />
[[File:fse-firefighter-rehabilitation-v5.jpg|thumb|upright=1.5|alt=Fire fighters with coats removed sitting in the shade drinking water while a paramedic measures blood pressure|Fire fighters in a rehabilitation area: protective coats off, fluids, shade and a blood pressure check by medical staff.]]


Fire departments often provided [[fire-based emergency medical services]] themselves. In 2000, a survey by the International Association of Fire Chiefs among its members found that over 90 percent of fire departments took part in delivering emergency medical services. Over 50 percent of the responding departments provided advanced life support transport.<ref name="Krakeel-13-149">Krakeel (2008), p. 13-149.</ref> Loflin (2008) describes the levels of fire service EMS, from first responder to the emergency medical technician levels basic, intermediate and paramedic.<ref name="Loflin-12-114" />
Fire departments often provided [[fire-based emergency medical services]] themselves. In 2000, a survey by the International Association of Fire Chiefs among its members found that over 90 percent of fire departments took part in delivering emergency medical services. Over 50 percent of the responding departments provided advanced life support transport.<ref name="Krakeel-13-149">Krakeel (2008), p. 13-149.</ref> Loflin (2008) describes the levels of fire service EMS, from first responder to the emergency medical technician levels basic, intermediate and paramedic.<ref name="Loflin-12-114" />
Line 54: Line 59:


For hot weather, Loflin lists typical measures. Fatigued or unassigned members move away from the hazardous area and remove their personal protective equipment. They stay out of direct sunlight, with natural or mechanical air movement over them, and receive fluids, especially water. Shade, fans, air conditioning and misting systems help to limit heat stress.<ref name="Loflin-12-124" />
For hot weather, Loflin lists typical measures. Fatigued or unassigned members move away from the hazardous area and remove their personal protective equipment. They stay out of direct sunlight, with natural or mechanical air movement over them, and receive fluids, especially water. Shade, fans, air conditioning and misting systems help to limit heat stress.<ref name="Loflin-12-124" />
[[File:fse-firefighter-rehabilitation-v2.svg|thumb|upright=1.5|alt=Two columns comparing hot weather and cold weather rehabilitation measures, with shared measures in the middle|Typical rehabilitation measures for hot and cold weather.]]


The FDNY procedure adds a caution on cooling. Members should not move from a hot environment directly into an air-conditioned area, because the body's cooling system can shut down in response to the external cooling. An air-conditioned space is acceptable only after a cool-down period at ambient temperature with enough air movement.<ref name="LV-A-RAC" /> For cold weather, the measures are moving members away from the hazardous area, shelter from wind and temperature extremes, and fluids, especially water. Heat, blankets and protection from the wind help to limit cold stress.<ref name="Loflin-12-124" />
The FDNY procedure adds a caution on cooling. Members should not move from a hot environment directly into an air-conditioned area, because the body's cooling system can shut down in response to the external cooling. An air-conditioned space is acceptable only after a cool-down period at ambient temperature with enough air movement.<ref name="LV-A-RAC" /> For cold weather, the measures are moving members away from the hazardous area, shelter from wind and temperature extremes, and fluids, especially water. Heat, blankets and protection from the wind help to limit cold stress.<ref name="Loflin-12-124" />

Latest revision as of 18:53, 14 November 2026

Firefighter rehabilitation, often shortened to rehab, is the organised rest, cooling or warming, rehydration, food and medical evaluation of fire fighters during and after work at an incident or training exercise. The 2008 handbook describes NFPA 1584 as a US recommended practice for rehabilitation at incident scenes and training exercises. As outlined by Loflin (2008), rehabilitation covers medical evaluation and treatment, food and fluid replenishment, relief from climatic conditions, rest and recovery, and member accountability.[1]

It answers a basic problem of fire fighting. Body temperature rises rapidly during work in insulating protective clothing, and long or labour-intensive incidents rapidly deplete the energy and strength of personnel.[2][3] Loflin (2008) recommends that the incident commander consider each incident and initiate rehabilitation under departmental procedures, NFPA 1584 and Chapter 8 of NFPA 1500. The rehabilitation area should be away from the hazardous area and have at least basic life support care.[4] This article describes practice as presented in sources up to 2008, mainly from the United States.

Purpose and principles

Discussing NFPA 1500, Loflin (2008) lists incident scene rest and rehabilitation among the components of operational risk management at emergency incidents, together with training, protective equipment, an incident safety officer and rapid intervention crews.[5] Loflin (2008) calls an organised approach to the rehabilitation of members an integral part both of an occupational safety and health programme and of incident scene management.[6] Elsewhere Loflin names effective training, rest and rehabilitation, continuous evaluation of changing conditions and past experience as further areas that are very important in reducing risks to members.[7]

The need follows from the conditions of the work. Teele (2008) explains that protective garments must insulate to protect against the hostile thermal environment of a fire, and that garments alone cannot keep a fire fighter both cool and protected.[8] Heat stress is affected by the fire fighter's age, physical condition and individual metabolism, and by how fire fighters are managed during an incident. Crews working in high-temperature areas or at high work rates must therefore be rotated periodically to allow rest, cooling, rehydration and monitoring of their physiological condition.[8]

Exertion also matters for the heart. In Hall and Cote's 2008 account, nearly half of all US fire fighter deaths in the line of duty in a typical year involved heart attacks.[9] Of the fire fighters who died from sudden cardiac death from 1995 through 2004, 35 percent suffered their symptoms during fireground operations.[10] Rehabilitation includes medical evaluation and treatment as well as rest.[4]

The same need exists beyond structural fire fighting. Hazardous materials protective equipment can itself create heat stress and physical and psychological stress.[11] For wildland fire fighters exposed to smoke, Teele (2008) lists short work periods, removal of crews from heavy smoke and rest periods in smoke-free air among the ways to reduce exposure.[12]

Development in the United States

NFPA 1584 grew out of the programme of standards that followed NFPA 1500, the first edition of which was passed in 1987.[13] Its 2003 edition was prepared by the Technical Committee on Fire Service Occupational Medical and Health. It was acted on at the NFPA meeting of 16–20 November 2002 in Atlanta, issued on 17 January 2003 and took effect on 6 February 2003.[6] It falls under the umbrella of NFPA 1500 (2002 edition), together with the standards on incident management, medical programmes, fitness, the safety officer and infection control.[6]

Loflin (2008) notes that incident scene rehabilitation had been discussed and used throughout the fire service in various sizes and configurations before the document existed. Many departments had used material from the United States Fire Administration and from emergency medical services, and progressive departments shared their lessons learned. As a recommended practice, NFPA 1584 sets the minimum level of criteria for developing and implementing a rehabilitation process at incident scene operations and at training exercises.[6]

Large departments wrote their own procedures. The incident command system manual of the Fire Department of the City of New York (FDNY), dated 17 July 1995 and reproduced by NIST, provides for a "Recuperation and Care" (RAC) area. It states that any incident that is large, long or labour-intensive will rapidly deplete the energy and strength of personnel and merits consideration for rehabilitation. Severe climatic or environmental conditions also make such an area necessary.[3] In the FDNY incident command system, rehabilitation areas are among the incident facilities handled by the logistics function.[14]

Physiology of heat, exertion and smoke

Purser (2002) describes how prolonged heat exposure that is too mild to burn still harms the body. In air below about 120 °C (dry) or 80 °C (saturated), the main effect is a gradual rise of body core temperature. A rise from the normal 37 °C to about 39 °C is within the physiological range and can occur during hard exercise. At 40 °C consciousness becomes blurred and the person becomes seriously ill, and above 42.5 °C the condition is fatal unless treated within minutes.[15]

Vertical thermometer scale from 36 to 44 degrees Celsius with bands for normal, hard exercise, seriously ill and fatal
Body core temperature bands from normal to fatal hyperthermia.

Below about 120 °C, evaporation of sweat is an important means of cooling. Clothing can then shorten the tolerance time by impeding that evaporative cooling, and a fire fighter may suffer heat stroke after an exposure longer than 15 minutes, especially in humid air and during hard work.[16] The general mechanisms are treated in Effects of heat on people.

Structural firefighting protective clothing adds to this load. Teele (2008) records the view that its thermal insulation causes more heat stress injuries than lighter, less protective garments. Teele rejects simply reducing the insulation or weight of the garments, because that would not have any meaningful effect on heat stress. In mild and moderate environments and at low and moderate work levels, garment materials can make an appreciable difference. In high-temperature environments or at high work rates they are unlikely to improve tolerance time significantly. NFPA standards addressed part of the problem with a total heat loss test that measures the breathability of garments.[8]

The World Trade Center response of 11 September 2001 showed these effects on a large scale. An FDNY fire fighter in full protective clothing and breathing apparatus carried about 23 kg of gear, and extra tools, hose and air cylinders could add another 23 kg or more.[17] Fire fighters climbed the first 10 to 12 floors in 2 to 5 minutes and then had to stop and rest; after that they usually managed only 5 to 6 floors between rests.[18]

Interviewees reported fatigue, thermal stress and dehydration, and a need for water.[2] During rests they took off their helmets and opened their coats, and some removed their breathing apparatus and coats to cool down. Several fire fighters suffered chest pains or heart attacks, and oxygen was given to them.[2] NIST notes that the protective clothing produced heat stress and added to the fatigue of the climb.[19]

Exertion also changes the effect of smoke. Purser (2002) explains that the uptake of carbon monoxide depends on the respiratory minute volume, and hence on the activity of the person. Active subjects are seriously affected at carboxyhaemoglobin levels that have only minor effects on sedentary ones.[20] In Purser's model for a 70 kg person, incapacitation is expected at about 40 percent carboxyhaemoglobin at rest, 30 percent during light work and 20 percent during heavy work. The corresponding breathing rates are 8.5, 25 and 50 L/min.[21] Teele (2008) notes that the particulate respirators used by some wildland fire fighters do nothing to protect against carbon monoxide.[12]

Bar chart with three bars for rest, light work and heavy work showing incapacitating carboxyhaemoglobin falling from 40 to 20 percent
Carboxyhaemoglobin level at which incapacitation is expected for a 70 kg person at rest, in light work and in heavy work, with breathing rates.

Organisation at the incident

Loflin (2008) recommends that each fire department write standard operating procedures with a systematic approach to rehabilitation. They should cover medical evaluation and treatment, food and fluid replenishment, crew rotation and relief from extreme climatic conditions. The procedures should describe an ongoing rehabilitation process for simple or short-duration incidents and a way to scale up to the needs of a large or long-duration incident.[4]

The incident commander considers the circumstances of each incident and initiates rest and rehabilitation. The incident safety officer has the task of making sure that the incident commander establishes an incident scene rehabilitation unit during emergency operations, as required by NFPA 1521.[22][4] At emergency medical operations, especially mass casualty incidents, the safety officer for special operations makes sure that rehabilitation and critical incident stress management are set up as needed. At hazardous materials incidents, the safety officer meets the incident commander to decide on rehabilitation needs and, for long-term operations, on food and hygiene facilities. The safety officer's post-incident report includes the rehabilitation operations.[5]

The rehabilitation area is organised as a group or division within the incident management system. It is placed in a safe environment away from the hazardous area of the incident. Its resources include an environment that limits temperature stress, medical equipment and adequate medical staff.[4]

Plan of an incident with the burning building and hazard zone on one side and a rehabilitation area with medical, rest and fluids zones on the other
Example layout of an incident scene rehabilitation area away from the hazardous area, with medical care, rest and climate relief, and food and fluids.

The FDNY procedure adds practical site criteria. The incident commander designates the location and may appoint a RAC officer, who can be a chief officer at large operations. The site must protect from the weather, be free of exhaust fumes, apparatus and equipment, give room for members to take off their bunker gear and be easily accessible to emergency medical services.[3] Enclosed rescue vehicles can serve as a sheltered environment for rehabilitation during inclement weather.[23]

Rehabilitation also supports accountability. Member accountability is one of the elements of rehabilitation under NFPA 1584.[1] In the FDNY procedure, units are considered for rehabilitation not only on the energy spent at the incident, but also on their activity before it. Battalion chiefs could grant rest periods of two hours and deputy chiefs of three hours.[3]

Medical evaluation and care

Medical care is one of the main elements of rehabilitation. Evaluation and treatment in the rehabilitation area follow emergency medical service protocols that the department develops with the fire department physician and the EMS medical director. If advanced life support (paramedic) personnel are available, that level of care is preferred. The minimum is basic life support. During long-duration or heavy-exertion operations, assigning an ambulance or other support crew to rehabilitation is essential, and advanced life support must be available quickly.[4]

Fire fighters with coats removed sitting in the shade drinking water while a paramedic measures blood pressure
Fire fighters in a rehabilitation area: protective coats off, fluids, shade and a blood pressure check by medical staff.

Fire departments often provided fire-based emergency medical services themselves. In 2000, a survey by the International Association of Fire Chiefs among its members found that over 90 percent of fire departments took part in delivering emergency medical services. Over 50 percent of the responding departments provided advanced life support transport.[24] Loflin (2008) describes the levels of fire service EMS, from first responder to the emergency medical technician levels basic, intermediate and paramedic.[7]

The medical equipment in the rehabilitation area should include blood pressure cuffs, stethoscopes, oxygen, cardiac monitors, thermometers, and intravenous fluids and supplies.[4] Loflin recommends medical evaluation for members showing signs or symptoms of heat exhaustion or heat stroke in hot weather, or frostbite, hypothermia or other cold-related injury in cold weather.[4]

Fluids, food and climate

Weather can have a severe effect on the safety and health of members. Loflin (2008) warns that when bad weather combines with long-duration incidents or heavy exertion, the risks increase rapidly. Departments should therefore develop procedures for relief from adverse climatic conditions in consultation with the fire department physician.[4]

For hot weather, Loflin lists typical measures. Fatigued or unassigned members move away from the hazardous area and remove their personal protective equipment. They stay out of direct sunlight, with natural or mechanical air movement over them, and receive fluids, especially water. Shade, fans, air conditioning and misting systems help to limit heat stress.[4]

Two columns comparing hot weather and cold weather rehabilitation measures, with shared measures in the middle
Typical rehabilitation measures for hot and cold weather.

The FDNY procedure adds a caution on cooling. Members should not move from a hot environment directly into an air-conditioned area, because the body's cooling system can shut down in response to the external cooling. An air-conditioned space is acceptable only after a cool-down period at ambient temperature with enough air movement.[3] For cold weather, the measures are moving members away from the hazardous area, shelter from wind and temperature extremes, and fluids, especially water. Heat, blankets and protection from the wind help to limit cold stress.[4]

Food and drink are among the rehabilitation provisions described by Loflin. Loflin (2008) lists water and other oral fluids, food, broth and fruit. A 50/50 mixture of water and an electrolyte replacement drink can be provided for hydration.[4] The FDNY procedure states that members in the rehabilitation area should keep a high level of hydration. During heat stress they should drink at least one quart of water per hour, which is about 0.95 L.[3]

Limits and open questions

NFPA 1584 is a recommended practice rather than a standard. It sets minimum criteria for a rehabilitation process.[6] Loflin (2008) leaves the details to each department's standard operating procedures.[4] The sources cited here give no general physiological thresholds for returning to duty, such as core temperature or heart rate, and no standard work-rest schedule. The 1995 FDNY procedure instead gives a water-intake target and permits two- or three-hour rest periods at chiefs' discretion.[3]

Rehabilitation cannot remove every limit on human performance. At the World Trade Center, climbing rates were estimated at about 1.4 minutes per floor for responders without extra equipment and about 2.0 minutes per floor for those in protective clothing with equipment. These estimates had an uncertainty of about 0.5 minutes per floor.[25] Fatigue became a factor after about 12 floors and reduced the capability of responders on arrival at the fire floor.[26]

NIST recommended fire-protected and structurally hardened elevators for emergency responders in tall buildings. It found that climbing 20 or more storeys makes effective and timely firefighting and rescue difficult.[27] The International Fire Engineering Guidelines likewise note that the time for search and rescue may be affected by the physiological demands of the activities.[28]

See also

Notes

  1. ↑ 1.0 1.1 Loflin (2008), pp. 12-117–12-118.
  2. ↑ 2.0 2.1 2.2 Lawson and Vettori (2005), p. 90.
  3. ↑ 3.0 3.1 3.2 3.3 3.4 3.5 3.6 Lawson and Vettori (2005), Appendix A, FDNY ICS Manual Part 4 (1995), pp. 2–3.
  4. ↑ 4.00 4.01 4.02 4.03 4.04 4.05 4.06 4.07 4.08 4.09 4.10 4.11 4.12 Loflin (2008), p. 12-124.
  5. ↑ 5.0 5.1 Loflin (2008), p. 12-112.
  6. ↑ 6.0 6.1 6.2 6.3 6.4 Loflin (2008), p. 12-117.
  7. ↑ 7.0 7.1 Loflin (2008), p. 12-114.
  8. ↑ 8.0 8.1 8.2 Teele (2008), p. 12-147.
  9. ↑ Hall and Cote (2008), p. 3-30.
  10. ↑ Ahrens et al. (2008), p. 3-64.
  11. ↑ C. J. Wright (2008a), p. 13-140.
  12. ↑ 12.0 12.1 Teele (2008), p. 12-154.
  13. ↑ Loflin (2008), p. 12-109.
  14. ↑ Lawson and Vettori (2005), Appendix A, FDNY ICS Manual Part 5 (1994), p. 41.
  15. ↑ Purser (2002), p. 2-125.
  16. ↑ Purser (2002), pp. 2-125–2-126.
  17. ↑ Lawson and Vettori (2005), p. 87.
  18. ↑ Lawson and Vettori (2005), p. 89.
  19. ↑ Lawson and Vettori (2005), p. 105.
  20. ↑ Purser (2002), p. 2-101.
  21. ↑ Purser (2002), p. 2-102.
  22. ↑ Loflin (2008), p. 12-111.
  23. ↑ Tutterow (2008), p. 12-278.
  24. ↑ Krakeel (2008), p. 13-149.
  25. ↑ Lawson and Vettori (2005), p. 91.
  26. ↑ Lawson and Vettori (2005), p. 73.
  27. ↑ National Institute of Standards and Technology (2005), pp. 218–219.
  28. ↑ National Research Council of Canada et al. (2005), p. 1.9-4.

References

  • Ahrens, M., Frazier, P., & Kelch, G. (2008). Use of fire incident data and statistics. In A. E. Cote, C. C. Grant, J. R. Hall, Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 3-61–3-92). National Fire Protection Association.
  • Hall, J. R., Jr., & Cote, A. E. (2008). An overview of the fire problem and fire protection. In A. E. Cote, C. C. Grant, J. R. Hall, Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 3-3–3-30). National Fire Protection Association.
  • Krakeel, J. J. (2008). Emergency medical services and the fire department. In A. E. Cote, C. C. Grant, J. R. Hall, Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 13-145–13-161). National Fire Protection Association.
  • Lawson, J. R., & Vettori, R. L. (2005). The emergency response operations (NIST NCSTAR 1-8). National Institute of Standards and Technology.
  • Loflin, M. E. (2008). Safety, medical, and health issues and programs. In A. E. Cote, C. C. Grant, J. R. Hall, Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 12-107–12-125). National Fire Protection Association.
  • National Institute of Standards and Technology. (2005). Final report on the collapse of the World Trade Center towers (NIST NCSTAR 1).
  • National Research Council of Canada, International Code Council, Department of Building and Housing, & Australian Building Codes Board. (2005). International fire engineering guidelines (2005 ed.). Australian Building Codes Board.
  • Purser, D. A. (2002). Toxicity assessment of combustion products. In P. J. DiNenno, D. Drysdale, C. L. Beyler, W. D. Walton, R. L. P. Custer, J. R. Hall Jr., & J. M. Watts Jr. (Eds.), SFPE handbook of fire protection engineering (3rd ed., pp. 2-83–2-171). National Fire Protection Association; Society of Fire Protection Engineers.
  • Teele, B. W. (2008). Fire and emergency services protective clothing and protective equipment. In A. E. Cote, C. C. Grant, J. R. Hall, Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 12-143–12-160). National Fire Protection Association.
  • Tutterow, R. (2008). Fire department apparatus and equipment. In A. E. Cote, C. C. Grant, J. R. Hall, Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 12-267–12-287). National Fire Protection Association.
  • Wright, C. J. (2008a). Managing the response to hazardous material incidents. In A. E. Cote, C. C. Grant, J. R. Hall, Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 13-117–13-144). National Fire Protection Association.