New FSE wiki article: Search and rescue (written by Claude Opus 5.5) |
Add SVG figures fse-search-and-rescue-v1.svg, fse-search-and-rescue-v2.svg, fse-search-and-rescue-v3.svg, fse-search-and-rescue-v4.svg (list-8 visual plan) |
||
| (2 intermediate revisions by one other user not shown) | |||
| Line 8: | Line 8: | ||
The ''International Fire Engineering Guidelines'' (IFEG, 2005) treat the completion of search and rescue as one output of a fire service analysis. They define its duration as the time taken to search, to assist evacuation where necessary, and to rescue people who are injured or having difficulty evacuating.<ref name="IFEG-1.9-4">National Research Council of Canada et al. (2005), p. 1.9-4.</ref> Fire conditions in the building and the physical demands of the work can both lengthen this time.<ref name="IFEG-1.9-4" /> Calculations may show that all occupants have left before the fire service arrives. In practice, however, the fire service may still search for trapped or injured occupants.<ref name="IFEG-1.9-5">National Research Council of Canada et al. (2005), p. 1.9-5.</ref> The same guidelines state that the analysis of occupant evacuation to a place of safety should not rely on fire service intervention.<ref name="IFEG-1.9-1" /> | The ''International Fire Engineering Guidelines'' (IFEG, 2005) treat the completion of search and rescue as one output of a fire service analysis. They define its duration as the time taken to search, to assist evacuation where necessary, and to rescue people who are injured or having difficulty evacuating.<ref name="IFEG-1.9-4">National Research Council of Canada et al. (2005), p. 1.9-4.</ref> Fire conditions in the building and the physical demands of the work can both lengthen this time.<ref name="IFEG-1.9-4" /> Calculations may show that all occupants have left before the fire service arrives. In practice, however, the fire service may still search for trapped or injured occupants.<ref name="IFEG-1.9-5">National Research Council of Canada et al. (2005), p. 1.9-5.</ref> The same guidelines state that the analysis of occupant evacuation to a place of safety should not rely on fire service intervention.<ref name="IFEG-1.9-1" /> | ||
US | These US sources distinguish two stages of search. The size-up checklist of Klaene and Sanders (2008) lists the staffing needed to complete a primary search and rescue and the staffing needed to complete a secondary search and rescue as separate items.<ref name="KS-13-6">Klaene and Sanders (2008), p. 13-6.</ref> In the 1997 high-rise procedures of the Fire Department of the City of New York (FDNY), the first-arriving ladder company makes the primary search of the fire floor. The command checklist records the completion of the primary search, the secondary search and the search of elevators as separate entries.<ref name="LV-AppI">Lawson and Vettori (2005), Appendix I.</ref> | ||
The US standard NFPA 1670, as described by Wright (2008), defines wilderness search and rescue as the location and removal of persons trapped or stranded within a wilderness environment.<ref name="RW-13-14" /> Urban search and rescue and large-scale disaster rescue are named as specialised forms that NFPA 1670 and NFPA 1006 do not address.<ref name="RW-13-15">R. Wright (2008), p. 13-15.</ref> Schmidt (2008) adds that facilities far from public emergency services, or in seismically active regions, may need their own search and rescue capability, because a major earthquake could overtax the public fire service.<ref name="Schmidt-1-146">Schmidt (2008), p. 1-146.</ref> This article deals with search at fires in buildings. | |||
== Place in fireground operations == | == Place in fireground operations == | ||
| Line 22: | Line 22: | ||
== Staffing and timing == | == Staffing and timing == | ||
Granito (2008) lists the search for and rescue of fire victims among the tasks that must be done almost simultaneously at an urban structure fire | Granito (2008) lists the search for and rescue of fire victims among the tasks, such as command, water supply, ventilation and forcible entry, that must be done almost simultaneously at an urban structure fire.<ref name="Granito-12-10">Granito (2008), p. 12-10.</ref> He defines a department's "capability" as its ability to arrive quickly with enough trained personnel to rescue any trapped occupants and to confine the fire on initial attack.<ref name="Granito-12-8">Granito (2008), p. 12-8.</ref> Granito (2008) reported that a 1995 US stipulation then still in force required at least four trained personnel on scene before interior attack, except in the most extenuating circumstances. Both OSHA and NFPA had issued documents on it.<ref name="Granito-12-8" /> Under NFPA 1500, as described by Loflin (2008), the initial crew at a working structure fire has at least four members. Two work in the hazard area while two stay outside, available for assistance or rescue.<ref name="Loflin-12-114">Loflin (2008), p. 12-114.</ref> | ||
Occupancies with a high life hazard need the most people. Granito (2008) states that schools, hospitals and nursing homes need especially large numbers for search and rescue, with several firefighters required to "sweep and search" each floor.<ref name="Granito-12-11">Granito (2008), p. 12-11.</ref> His typical initial attack response for such high-hazard occupancies is at least 4 pumpers, 2 ladder trucks, not fewer than 24 firefighters and 2 chief officers, plus safety officers and a rapid intervention team. For one- to three-family dwellings he gives at least 14 firefighters and 1 chief officer.<ref name="Granito-12-12">Granito (2008), p. 12-12.</ref> Seriously understaffed companies are generally limited to small hose streams, which may be ineffective for both fire containment and rescue.<ref name="Granito-12-12" /> | Occupancies with a high life hazard need the most people. Granito (2008) states that schools, hospitals and nursing homes need especially large numbers for search and rescue, with several firefighters required to "sweep and search" each floor.<ref name="Granito-12-11">Granito (2008), p. 12-11.</ref> His typical initial attack response for such high-hazard occupancies is at least 4 pumpers, 2 ladder trucks, not fewer than 24 firefighters and 2 chief officers, plus safety officers and a rapid intervention team. For one- to three-family dwellings he gives at least 14 firefighters and 1 chief officer.<ref name="Granito-12-12">Granito (2008), p. 12-12.</ref> Seriously understaffed companies are generally limited to small hose streams, which may be ineffective for both fire containment and rescue.<ref name="Granito-12-12" /> | ||
[[File:fse-search-and-rescue-v1.svg|thumb|upright=1.5|alt=Bar chart of minimum firefighters in the typical US initial attack response for four occupancy classes|Typical initial attack response (US, 2008) by occupancy class: minimum number of firefighters plus chief officers, each with a safety officer and a rapid intervention team.]] | |||
A rule of thumb in the same chapter provides one company for each 250 gpm (946 L/min) needed in an interior attack. Personnel for rescue and other simultaneous operations come on top of that.<ref name="Granito-12-13" /> Time is the other constraint. | A rule of thumb in the same chapter provides one company for each 250 gpm (946 L/min) needed in an interior attack. Personnel for rescue and other simultaneous operations come on top of that.<ref name="Granito-12-13" /> Time is the other constraint. Granito (2008) gives a generally considered five-minute goal from the station alarm to first-apparatus arrival. Further minutes are needed for size-up, hose deployment and search and rescue.<ref name="Granito-12-13" /> Johnson and Price (2008) note that flashover occurs most frequently between 4 and 10 minutes after free burning starts. A post-flashover fire burns hotter and moves faster, which compounds the search and rescue problem in the rest of the structure just when more firefighters are needed for fire attack.<ref name="JP-12-217" /> | ||
Purser's analysis of heat, smoke and toxic exposure in one test fire illustrates how short the time can be for a person in the room of fire origin. Purser (2002) analysed a test fire in which a single upholstered armchair burned in a room. Smoke and irritant gases would have severely hindered escape by the end of the second minute, and heat would have incapacitated an occupant during the fourth minute, at an average air temperature of 220 °C.<ref name="Purser-2-131">Purser (2002), p. 2-131.</ref> A victim rescued after the fourth minute was predicted to suffer severe and possibly fatal after-effects. A victim rescued after the sixth minute would probably die within a few minutes to an hour.<ref name="Purser-2-131" /> The analysis concerns a single fuel package in one room and is not a general survival time. | |||
== Large and high-rise buildings == | == Large and high-rise buildings == | ||
| Line 36: | Line 37: | ||
Under these procedures, the first-arriving ladder company makes the primary search of the fire floor, and the second assists it because of the large area to be covered.<ref name="LV-AppI" /> The third company searches the floor above the fire and clears occupants from the attack stairway. If this proves difficult, its officer may ask for the fire attack to be withheld until the occupants are safe.<ref name="LV-AppI" /> The fourth company goes to the roof, searches the top five floors, and each member carries a spare breathing apparatus cylinder.<ref name="LV-AppI" /> | Under these procedures, the first-arriving ladder company makes the primary search of the fire floor, and the second assists it because of the large area to be covered.<ref name="LV-AppI" /> The third company searches the floor above the fire and clears occupants from the attack stairway. If this proves difficult, its officer may ask for the fire attack to be withheld until the occupants are safe.<ref name="LV-AppI" /> The fourth company goes to the roof, searches the top five floors, and each member carries a spare breathing apparatus cylinder.<ref name="LV-AppI" /> | ||
[[File:fse-search-and-rescue-v2.svg|thumb|upright=1.5|alt=Section of a high-rise building showing which ladder company searches the fire floor, the floor above and the top five floors|Search assignments in the 1997 FDNY procedures for high-rise office buildings.]] | |||
Above the fire, the FDNY procedures place a search and evacuation post, run by the third or fourth arriving battalion chief. It controls all operations above the fire floor and the floor above it, and it is set up at least five floors above the fire floor.<ref name="LV-AppI" /> The lobby command post must supply it with at least one unit for every five floors to be covered.<ref name="LV-AppI" /> | Above the fire, the FDNY procedures place a search and evacuation post, run by the third or fourth arriving battalion chief. It controls all operations above the fire floor and the floor above it, and it is set up at least five floors above the fire floor.<ref name="LV-AppI" /> The lobby command post must supply it with at least one unit for every five floors to be covered.<ref name="LV-AppI" /> | ||
| Line 44: | Line 46: | ||
== Firefighter safety and tenability == | == Firefighter safety and tenability == | ||
Wright (2008) proposes "Don't become a victim" as a motto for rescue personnel. He notes that many well-intentioned rescuers have died while trying to save others, adding another victim to an already difficult situation.<ref name="RW-13-13" /> | Wright (2008) proposes "Don't become a victim" as a motto for rescue personnel. He notes that many well-intentioned rescuers have died while trying to save others, adding another victim to an already difficult situation.<ref name="RW-13-13" /> Teele (2008) reports that US OSHA regulations and NFPA standards required positive-pressure [[Self-contained breathing apparatus]] in any atmosphere that was, or might be, immediately dangerous to life and health. This included structural firefighting; the use of only positive-pressure units became mandatory in the United States on 1 July 1983.<ref name="Teele-12-151">Teele (2008), p. 12-151.</ref> In the deployment rules described by Loflin (2008), at least one [[Rapid intervention crew]] for the rescue of firefighters is required once a second crew works in the hazardous area.<ref name="Loflin-12-114" /> | ||
Protective equipment and breathing apparatus increase firefighters' resistance to heat and protect them against toxic gases, so design guidance uses separate [[Tenability criteria]] for them.<ref name="ABCB20-87">Australian Building Codes Board (2020b), p. 87.</ref> The Australian handbook to the Fire Safety Verification Method (2020) takes these criteria from the Fire Brigade Intervention Model (FBIM) manual of the Australasian Fire Authorities Council (AFAC).<ref name="ABCB20-111">Australian Building Codes Board (2020b), p. 111.</ref> They apply at 1.5 m above the floor and must be confirmed with the fire brigade during the design brief.<ref name="ABCB20-112">Australian Building Codes Board (2020b), p. 112.</ref> For occupants, the same handbook uses limits at 2 m height, such as a visibility of 10 m.<ref name="ABCB20-110">Australian Building Codes Board (2020b), p. 110.</ref> | Protective equipment and breathing apparatus increase firefighters' resistance to heat and protect them against toxic gases, so design guidance uses separate [[Tenability criteria]] for them.<ref name="ABCB20-87">Australian Building Codes Board (2020b), p. 87.</ref> The Australian handbook to the Fire Safety Verification Method (2020) takes these criteria from the Fire Brigade Intervention Model (FBIM) manual of the Australasian Fire Authorities Council (AFAC).<ref name="ABCB20-111">Australian Building Codes Board (2020b), p. 111.</ref> They apply at 1.5 m above the floor and must be confirmed with the fire brigade during the design brief.<ref name="ABCB20-112">Australian Building Codes Board (2020b), p. 112.</ref> For occupants, the same handbook uses limits at 2 m height, such as a visibility of 10 m.<ref name="ABCB20-110">Australian Building Codes Board (2020b), p. 110.</ref> | ||
| Line 62: | Line 64: | ||
The criteria assume full protective equipment and breathing apparatus, so exposure to toxic gases is not generally relevant for firefighters.<ref name="ABCB20-111" /> Visibility is not a firefighter criterion, but poor visibility slows search and rescue, and the capacity of the breathing apparatus cylinders may end the work before the heat limits are reached.<ref name="ABCB20-111" /> The FBIM manual warns that firefighters can search in conditions untenable for occupants, who are unlikely to survive them. It states that search and rescue cannot be undertaken in a compartment that has reached flashover.<ref name="ABCB20-113" /> | The criteria assume full protective equipment and breathing apparatus, so exposure to toxic gases is not generally relevant for firefighters.<ref name="ABCB20-111" /> Visibility is not a firefighter criterion, but poor visibility slows search and rescue, and the capacity of the breathing apparatus cylinders may end the work before the heat limits are reached.<ref name="ABCB20-111" /> The FBIM manual warns that firefighters can search in conditions untenable for occupants, who are unlikely to survive them. It states that search and rescue cannot be undertaken in a compartment that has reached flashover.<ref name="ABCB20-113" /> | ||
[[File:fse-search-and-rescue-v3.svg|thumb|upright=1.5|alt=Firefighter time, temperature and radiation criteria for routine, hazardous, extreme and critical conditions|Firefighter tenability conditions of the AFAC Fire Brigade Intervention Model, at 1.5 m above the floor.]] | |||
Dutch guidance also sets limits for fire service operations. Van Rossum (2027) reports that the Dutch standard NEN 6093 gives limit values for a fire service deployment in a space with a smoke and heat exhaust system. They include a visibility of at least 100 m to luminous objects up to 1.8 m height and a radiation flux from the smoke layer of at most 3.5 kW/m² at 1.8 m. The calculated smoke layer temperature may not exceed 200 °C with goods in the layer, 500 °C otherwise, or the critical temperature of the load-bearing structure.<ref name="VR-9.3b">Van Rossum (2027), §9.3 (Results from zone models).</ref> He stresses that a favourable engineering result does not mean the fire service will make an interior attack: that decision is always made by the crews on site.<ref name="VR-9.3b" /> | Dutch guidance also sets limits for fire service operations. Van Rossum (2027) reports that the Dutch standard NEN 6093 gives limit values for a fire service deployment in a space with a smoke and heat exhaust system. They include a visibility of at least 100 m to luminous objects up to 1.8 m height and a radiation flux from the smoke layer of at most 3.5 kW/m² at 1.8 m. The calculated smoke layer temperature may not exceed 200 °C with goods in the layer, 500 °C otherwise, or the critical temperature of the load-bearing structure.<ref name="VR-9.3b">Van Rossum (2027), §9.3 (Results from zone models).</ref> He stresses that a favourable engineering result does not mean the fire service will make an interior attack: that decision is always made by the crews on site.<ref name="VR-9.3b" /> | ||
| Line 69: | Line 72: | ||
== Search and rescue in fire safety engineering and regulation == | == Search and rescue in fire safety engineering and regulation == | ||
In performance-based design, fire service intervention is analysed as a chain of events. The IFEG (2005) give guidance on quantifying the times of arrival, investigation, set-up, search and rescue, fire attack, fire control and extinguishment.<ref name="IFEG-1.9-1" /> Their step-by-step procedure starts with the notification of the fire service and ends when the agreed end time of the analysis is reached.<ref name="IFEG-1.9-6">National Research Council of Canada et al. (2005), p. 1.9-6.</ref><ref name="IFEG-1.9-7">National Research Council of Canada et al. (2005), p. 1.9-7.</ref> Some of these steps may run at the same time; a conservative analysis treats them one after another.<ref name="IFEG-1.9-6" /> The step for search and rescue is omitted where all occupants have evacuated and been accounted for.<ref name="IFEG-1.9-6" /> | In performance-based design, fire service intervention is analysed as a chain of events. The IFEG (2005) give guidance on quantifying the times of arrival, investigation, set-up, search and rescue, fire attack, fire control and extinguishment.<ref name="IFEG-1.9-1" /> Their step-by-step procedure starts with the notification of the fire service and ends when the agreed end time of the analysis is reached.<ref name="IFEG-1.9-6">National Research Council of Canada et al. (2005), p. 1.9-6.</ref><ref name="IFEG-1.9-7">National Research Council of Canada et al. (2005), p. 1.9-7.</ref> Some of these steps may run at the same time; a conservative analysis treats them one after another.<ref name="IFEG-1.9-6" /> The step for search and rescue is omitted where all occupants have evacuated and been accounted for.<ref name="IFEG-1.9-6" /> | ||
[[File:fse-search-and-rescue-v4.svg|thumb|upright=1.5|alt=Flowchart of fire service intervention from notification through search and rescue to fire attack and its effect|Sequence of fire service intervention events in the International Fire Engineering Guidelines; search and rescue is omitted when all occupants have evacuated and been accounted for.]] | |||
The main Australian tool for this analysis is the AFAC FBIM, which uses up to 16 flow charts, one of which gives the search and rescue time.<ref name="IFEG-2.9-2">National Research Council of Canada et al. (2005), p. 2.9-2.</ref><ref name="IFEG-2.9-3">National Research Council of Canada et al. (2005), p. 2.9-3.</ref><ref name="IFEG-2.9-5">National Research Council of Canada et al. (2005), p. 2.9-5.</ref> Its prioritised outcomes include protecting firefighters, who must be given a reasonable time to search for trapped occupants before conditions become hazardous to them.<ref name="IFEG-2.9-3" /> A common tactic described in the model is for some firefighters to locate and assess the fire while others check for trapped occupants close to it. Suppression may then buy time for an interior search of the rest of the building.<ref name="IFEG-2.9-3" /> The model can estimate how long firefighters will be inside for search and rescue, a period during which their tenability and the structural stability should be maintained.<ref name="IFEG-2.9-4">National Research Council of Canada et al. (2005), p. 2.9-4.</ref> | The main Australian tool for this analysis is the AFAC FBIM, which uses up to 16 flow charts, one of which gives the search and rescue time.<ref name="IFEG-2.9-2">National Research Council of Canada et al. (2005), p. 2.9-2.</ref><ref name="IFEG-2.9-3">National Research Council of Canada et al. (2005), p. 2.9-3.</ref><ref name="IFEG-2.9-5">National Research Council of Canada et al. (2005), p. 2.9-5.</ref> Its prioritised outcomes include protecting firefighters, who must be given a reasonable time to search for trapped occupants before conditions become hazardous to them.<ref name="IFEG-2.9-3" /> A common tactic described in the model is for some firefighters to locate and assess the fire while others check for trapped occupants close to it. Suppression may then buy time for an interior search of the rest of the building.<ref name="IFEG-2.9-3" /> The model can estimate how long firefighters will be inside for search and rescue, a period during which their tenability and the structural stability should be maintained.<ref name="IFEG-2.9-4">National Research Council of Canada et al. (2005), p. 2.9-4.</ref> | ||
| Line 76: | Line 80: | ||
New Zealand's Verification Method C/VM2 (second edition, 2025) has a firefighting operations scenario based on the code objective to facilitate firefighting and rescue operations. Building Code clause C5.6 requires buildings to let firefighters reach the floor of fire origin, search the general area of fire origin and protect their means of egress.<ref name="CVM2-53" /> Clause C6.3 requires the structural systems that give firefighters safe access to floors to remain stable during and after fire.<ref name="CVM2-53" /> | New Zealand's Verification Method C/VM2 (second edition, 2025) has a firefighting operations scenario based on the code objective to facilitate firefighting and rescue operations. Building Code clause C5.6 requires buildings to let firefighters reach the floor of fire origin, search the general area of fire origin and protect their means of egress.<ref name="CVM2-53" /> Clause C6.3 requires the structural systems that give firefighters safe access to floors to remain stable during and after fire.<ref name="CVM2-53" /> | ||
For buildings with an escape height above 10 m, the load-carrying structure and floors must resist collapse until burnout.<ref name="CVM2-55">Ministry of Business, Innovation and Employment (2025b), p. 55.</ref> For | For buildings with an escape height above 10 m, the main load-carrying structure and floors must generally resist collapse until burnout; some small intermediate floors may instead qualify for a 30-minute minimum.<ref name="CVM2-55">Ministry of Business, Innovation and Employment (2025b), p. 55.</ref> For buildings with an escape height of at most 10 m, floors must resist collapse for at least 30 minutes, while access stairways must withstand at least 60 minutes or burnout. This provision is intended to permit search and rescue and to avoid sudden collapse that would endanger firefighters.<ref name="CVM2-55" /> A worked example in the 2013 commentary calls the scenario prescriptive because no design methodology existed. It links the scenario to firefighter safety during search and rescue and firefighting.<ref name="MBIE13-196">Ministry of Business, Innovation and Employment (2013), p. 196.</ref> | ||
Similar aims appear elsewhere. NIST's World Trade Center investigation describes the objective of minimum fire-resistance ratings in building codes as preventing local structural collapse until occupants can escape and the fire service can complete search and rescue.<ref name="Carino-6">Carino et al. (2005), p. 6.</ref> In the Netherlands, one of the sub-goals of the building regulations in the ''Besluit bouwwerken leefomgeving'' (Bbl) is to maintain the attack routes of the fire service.<ref name="VR-1.2">Van Rossum (2027), §1.2.</ref> | Similar aims appear elsewhere. NIST's World Trade Center investigation describes the objective of minimum fire-resistance ratings in building codes as preventing local structural collapse until occupants can escape and the fire service can complete search and rescue.<ref name="Carino-6">Carino et al. (2005), p. 6.</ref> In the Netherlands, one of the sub-goals of the building regulations in the ''Besluit bouwwerken leefomgeving'' (Bbl) is to maintain the attack routes of the fire service.<ref name="VR-1.2">Van Rossum (2027), §1.2.</ref> | ||
Latest revision as of 18:13, 14 November 2026
Search and rescue is the fire service activity of finding people who are trapped, injured or unable to leave a burning building or other dangerous place, and moving them to safety. The 2008 Fire Protection Handbook notes that to rescue literally means to remove from confinement or danger, and it counts interior search and rescue at fires among the "typical", frequently performed forms of rescue.[1] In US fireground operations, life safety is the first of three operational priorities, ahead of extinguishment and property conservation.[2] Search and rescue competes with fire attack for the first crews on scene, and it is time-critical because a fire can reach flashover within minutes.[3][4]
Firefighters with breathing apparatus can search in conditions that occupants could not survive, but not in a room that has reached flashover, and design guidance sets separate exposure limits for them.[5] Fire safety engineering treats search and rescue as one stage of the fire brigade intervention time line.[6] The verification methods for performance-based design in Australia and New Zealand require designers to show that firefighters can carry it out safely.[7][8] Rescue from collapsed structures, confined spaces, water and wilderness is organised separately as Technical rescue.[9]
Definition and scope
Wright (2008) separates "typical" rescues from specialised technical rescue. Typical rescues include interior search and rescue within fireground operations and the extrication of people trapped in cars after crashes.[1] Because such rescues occur regularly, the task becomes somewhat routine, and response organisations find it easier to keep their crews competent.[9] Specialised rescues are rare but vital, and their rarity may make them the most dangerous, because errors of judgement and gaps in skill are more likely.[9]
The International Fire Engineering Guidelines (IFEG, 2005) treat the completion of search and rescue as one output of a fire service analysis. They define its duration as the time taken to search, to assist evacuation where necessary, and to rescue people who are injured or having difficulty evacuating.[10] Fire conditions in the building and the physical demands of the work can both lengthen this time.[10] Calculations may show that all occupants have left before the fire service arrives. In practice, however, the fire service may still search for trapped or injured occupants.[11] The same guidelines state that the analysis of occupant evacuation to a place of safety should not rely on fire service intervention.[6]
These US sources distinguish two stages of search. The size-up checklist of Klaene and Sanders (2008) lists the staffing needed to complete a primary search and rescue and the staffing needed to complete a secondary search and rescue as separate items.[12] In the 1997 high-rise procedures of the Fire Department of the City of New York (FDNY), the first-arriving ladder company makes the primary search of the fire floor. The command checklist records the completion of the primary search, the secondary search and the search of elevators as separate entries.[13]
The US standard NFPA 1670, as described by Wright (2008), defines wilderness search and rescue as the location and removal of persons trapped or stranded within a wilderness environment.[9] Urban search and rescue and large-scale disaster rescue are named as specialised forms that NFPA 1670 and NFPA 1006 do not address.[14] Schmidt (2008) adds that facilities far from public emergency services, or in seismically active regions, may need their own search and rescue capability, because a major earthquake could overtax the public fire service.[15] This article deals with search at fires in buildings.
Place in fireground operations
Klaene and Sanders (2008) rank the US operational priorities at a structure fire as life safety, extinguishment and property conservation. When occupants are known to be inside a burning building, life safety factors are pre-eminent.[2] The life safety part of the Size-up checklist covers the evacuation status, the estimated number of people inside and their proximity to the fire. It also covers their mobility, awareness and familiarity with the building, the rescue options and the medical status of occupants.[12]
The decision to send crews inside rests on a risk-benefit analysis. NFPA 1500, as quoted by Klaene and Sanders (2008), limits activities that present a significant risk to members to situations with a potential to save endangered lives. It also states that no risk is acceptable when there is no possibility to save lives or property.[16] Once savable occupants and firefighters are out of the building, the benefit side of the analysis shrinks, and so does the level of acceptable risk.[12] Extinguishment is only the second priority, yet an offensive interior attack is often the most important life safety tactic.[17] Proper ventilation can pull fire away from trapped occupants and their means of egress, whereas improper ventilation can draw fire towards victims.[18]
Search and rescue is traditionally a truck company task in US Firefighting. Engine companies extinguish the fire, while truck crews gain entry, raise ladders, ventilate and evacuate occupants. An engine crew can still be given a truck task such as search and rescue.[17] Denlinger (2008) names search and rescue, forcible entry, ventilation, salvage and overhaul as the fireground duties of ladder companies, which also use ladders to rescue people trapped above ground level.[19] Where departments operate separate rescue companies, these are usually assigned on the fireground primarily to search and rescue and to medical treatment.[20]
The building's own exits are the preferred way out. If the stairways are not compromised, they offer the easiest and safest route from upper floors.[17] Interior stairs, fire escapes, aerial apparatus and ground ladders are the common rescue methods. Elevators, scaling ladders, ropes, helicopters, life nets and air bags are atypical methods that often expose rescuer and victim to extraordinary danger.[17] The incident commander needs enough staff to extinguish or contain the fire, to search, and to treat and transport the injured while preventing re-entry. The number depends on the occupants at risk, their condition, the rescue methods, fire size, smoke, weather and the need to force entry.[17]
Staffing and timing
Granito (2008) lists the search for and rescue of fire victims among the tasks, such as command, water supply, ventilation and forcible entry, that must be done almost simultaneously at an urban structure fire.[21] He defines a department's "capability" as its ability to arrive quickly with enough trained personnel to rescue any trapped occupants and to confine the fire on initial attack.[22] Granito (2008) reported that a 1995 US stipulation then still in force required at least four trained personnel on scene before interior attack, except in the most extenuating circumstances. Both OSHA and NFPA had issued documents on it.[22] Under NFPA 1500, as described by Loflin (2008), the initial crew at a working structure fire has at least four members. Two work in the hazard area while two stay outside, available for assistance or rescue.[23]
Occupancies with a high life hazard need the most people. Granito (2008) states that schools, hospitals and nursing homes need especially large numbers for search and rescue, with several firefighters required to "sweep and search" each floor.[24] His typical initial attack response for such high-hazard occupancies is at least 4 pumpers, 2 ladder trucks, not fewer than 24 firefighters and 2 chief officers, plus safety officers and a rapid intervention team. For one- to three-family dwellings he gives at least 14 firefighters and 1 chief officer.[25] Seriously understaffed companies are generally limited to small hose streams, which may be ineffective for both fire containment and rescue.[25]
A rule of thumb in the same chapter provides one company for each 250 gpm (946 L/min) needed in an interior attack. Personnel for rescue and other simultaneous operations come on top of that.[3] Time is the other constraint. Granito (2008) gives a generally considered five-minute goal from the station alarm to first-apparatus arrival. Further minutes are needed for size-up, hose deployment and search and rescue.[3] Johnson and Price (2008) note that flashover occurs most frequently between 4 and 10 minutes after free burning starts. A post-flashover fire burns hotter and moves faster, which compounds the search and rescue problem in the rest of the structure just when more firefighters are needed for fire attack.[4]
Purser's analysis of heat, smoke and toxic exposure in one test fire illustrates how short the time can be for a person in the room of fire origin. Purser (2002) analysed a test fire in which a single upholstered armchair burned in a room. Smoke and irritant gases would have severely hindered escape by the end of the second minute, and heat would have incapacitated an occupant during the fourth minute, at an average air temperature of 220 °C.[26] A victim rescued after the fourth minute was predicted to suffer severe and possibly fatal after-effects. A victim rescued after the sixth minute would probably die within a few minutes to an hour.[26] The analysis concerns a single fuel package in one room and is not a general survival time.
Large and high-rise buildings
Large, complex buildings make search harder and increase the risk to firefighters. Flexible floor plans and multiple additions can create a maze-like layout with confusing routes to the exits.[17] Klaene and Sanders (2008) cite the Beverly Hills Supper Club as an example. That 1977 fire in Kentucky killed 165 people, less than 10 percent of the 2,400 to 2,800 occupants reportedly on site.[27] Watts (2008b) adds that inadequate interior access can delay or prevent the rescue of trapped occupants, and that obstacles to ventilation let smoke accumulate and obscure firefighters' vision.[28] In some buildings, smoke purge systems may be appropriate to clear smoke and heat during fire-fighting and search and rescue operations.[29]
High-rise buildings need a planned division of the search. The FDNY procedures for high-rise office buildings in force on 11 September 2001 are reproduced in the NIST report on the emergency response at the World Trade Center.[30] They warn that occupants of the fire floor may be unaware of the fire until it is too late, because of large floor areas or maze-like corridors. Large areas must therefore be searched, and the floor above the fire must also be searched and evacuated.[31]
Under these procedures, the first-arriving ladder company makes the primary search of the fire floor, and the second assists it because of the large area to be covered.[13] The third company searches the floor above the fire and clears occupants from the attack stairway. If this proves difficult, its officer may ask for the fire attack to be withheld until the occupants are safe.[13] The fourth company goes to the roof, searches the top five floors, and each member carries a spare breathing apparatus cylinder.[13]
Above the fire, the FDNY procedures place a search and evacuation post, run by the third or fourth arriving battalion chief. It controls all operations above the fire floor and the floor above it, and it is set up at least five floors above the fire floor.[13] The lobby command post must supply it with at least one unit for every five floors to be covered.[13]
On 11 September 2001, the fires in WTC 1 were very high in the building and its water supply was compromised. The chiefs at the lobby command post therefore directed the effort to evacuation and rescue. Companies arriving after the first ones had gone up were instructed only to carry out occupant evacuation and search and rescue.[32] At the MGM Grand Hotel fire in Las Vegas in 1980, which killed 85 people, the fire department rescued about 900 guests, while about 300 were evacuated by helicopter.[33][34]
Other settings change the method. At aircraft fires, guidance from the International Fire Service Training Association, as described by Kreckie (2008), is to start entry, search and rescue and interior fire attack from the unburned side of the aircraft. Where trapped victims must be extricated, making the cabin atmosphere safe may be the only alternative to removing them.[35]
Firefighter safety and tenability
Wright (2008) proposes "Don't become a victim" as a motto for rescue personnel. He notes that many well-intentioned rescuers have died while trying to save others, adding another victim to an already difficult situation.[1] Teele (2008) reports that US OSHA regulations and NFPA standards required positive-pressure Self-contained breathing apparatus in any atmosphere that was, or might be, immediately dangerous to life and health. This included structural firefighting; the use of only positive-pressure units became mandatory in the United States on 1 July 1983.[36] In the deployment rules described by Loflin (2008), at least one Rapid intervention crew for the rescue of firefighters is required once a second crew works in the hazardous area.[23]
Protective equipment and breathing apparatus increase firefighters' resistance to heat and protect them against toxic gases, so design guidance uses separate Tenability criteria for them.[37] The Australian handbook to the Fire Safety Verification Method (2020) takes these criteria from the Fire Brigade Intervention Model (FBIM) manual of the Australasian Fire Authorities Council (AFAC).[38] They apply at 1.5 m above the floor and must be confirmed with the fire brigade during the design brief.[39] For occupants, the same handbook uses limits at 2 m height, such as a visibility of 10 m.[40]
| Condition | Situation | Maximum time | Maximum air temperature | Maximum radiation |
|---|---|---|---|---|
| Routine | Elevated temperatures, no direct thermal radiation | 25 min | 100 °C (lower layer) | 1 kW/m² |
| Hazardous | Short period in high temperature with direct radiation | 10 min | 120 °C (lower layer) | 3 kW/m² |
| Extreme | Snatch rescue or retreat from a flashover | 1 min | 160 °C (lower layer), 280 °C (upper layer) | 4–4.5 kW/m² |
| Critical | Not expected to operate; life-threatening | less than 1 min | above 235 °C (lower layer) | above 10 kW/m² |
The criteria assume full protective equipment and breathing apparatus, so exposure to toxic gases is not generally relevant for firefighters.[38] Visibility is not a firefighter criterion, but poor visibility slows search and rescue, and the capacity of the breathing apparatus cylinders may end the work before the heat limits are reached.[38] The FBIM manual warns that firefighters can search in conditions untenable for occupants, who are unlikely to survive them. It states that search and rescue cannot be undertaken in a compartment that has reached flashover.[5]
Dutch guidance also sets limits for fire service operations. Van Rossum (2027) reports that the Dutch standard NEN 6093 gives limit values for a fire service deployment in a space with a smoke and heat exhaust system. They include a visibility of at least 100 m to luminous objects up to 1.8 m height and a radiation flux from the smoke layer of at most 3.5 kW/m² at 1.8 m. The calculated smoke layer temperature may not exceed 200 °C with goods in the layer, 500 °C otherwise, or the critical temperature of the load-bearing structure.[41] He stresses that a favourable engineering result does not mean the fire service will make an interior attack: that decision is always made by the crews on site.[41]
Klaene and Sanders (2008) list thermal imaging devices among the innovations that aid fireground operations.[42] These cameras detect temperature differences through smoke and darkness, and their uses include searching for fire victims, for missing persons and for hidden fire.[43] In the US needs assessment surveys described by Jenaway (2008), the share of fire departments with thermal imaging cameras rose from 24 percent in the 2001 survey to 55 percent in the 2005 assessment.[44]
Search and rescue in fire safety engineering and regulation
In performance-based design, fire service intervention is analysed as a chain of events. The IFEG (2005) give guidance on quantifying the times of arrival, investigation, set-up, search and rescue, fire attack, fire control and extinguishment.[6] Their step-by-step procedure starts with the notification of the fire service and ends when the agreed end time of the analysis is reached.[45][46] Some of these steps may run at the same time; a conservative analysis treats them one after another.[45] The step for search and rescue is omitted where all occupants have evacuated and been accounted for.[45]
The main Australian tool for this analysis is the AFAC FBIM, which uses up to 16 flow charts, one of which gives the search and rescue time.[47][48][49] Its prioritised outcomes include protecting firefighters, who must be given a reasonable time to search for trapped occupants before conditions become hazardous to them.[48] A common tactic described in the model is for some firefighters to locate and assess the fire while others check for trapped occupants close to it. Suppression may then buy time for an interior search of the rest of the building.[48] The model can estimate how long firefighters will be inside for search and rescue, a period during which their tenability and the structural stability should be maintained.[50]
In Australia, the Fire Safety Verification Method Standard 2022 contains a fire brigade intervention design scenario. Its required outcome is to show that the fire brigade can undertake intervention until search and rescue is complete.[7] The scenario applies only to buildings within 50 km road travel of a fire station and is demonstrated with the AFAC FBIM.[7] Access to normally occupied areas for search and rescue is required in all unsprinklered buildings, and in sprinklered buildings with more than 50 occupants.[51] The accompanying handbook also compares the risk of major structural collapse before search and rescue is complete.[52]
New Zealand's Verification Method C/VM2 (second edition, 2025) has a firefighting operations scenario based on the code objective to facilitate firefighting and rescue operations. Building Code clause C5.6 requires buildings to let firefighters reach the floor of fire origin, search the general area of fire origin and protect their means of egress.[8] Clause C6.3 requires the structural systems that give firefighters safe access to floors to remain stable during and after fire.[8]
For buildings with an escape height above 10 m, the main load-carrying structure and floors must generally resist collapse until burnout; some small intermediate floors may instead qualify for a 30-minute minimum.[53] For buildings with an escape height of at most 10 m, floors must resist collapse for at least 30 minutes, while access stairways must withstand at least 60 minutes or burnout. This provision is intended to permit search and rescue and to avoid sudden collapse that would endanger firefighters.[53] A worked example in the 2013 commentary calls the scenario prescriptive because no design methodology existed. It links the scenario to firefighter safety during search and rescue and firefighting.[54]
Similar aims appear elsewhere. NIST's World Trade Center investigation describes the objective of minimum fire-resistance ratings in building codes as preventing local structural collapse until occupants can escape and the fire service can complete search and rescue.[55] In the Netherlands, one of the sub-goals of the building regulations in the Besluit bouwwerken leefomgeving (Bbl) is to maintain the attack routes of the fire service.[56]
See also
- Fire company staffing
- Pre-incident planning
- Personnel accountability system
- Building collapse during firefighting
- Aircraft rescue and firefighting
- Incident command system
Notes
- ↑ 1.0 1.1 1.2 R. Wright (2008), p. 13-13.
- ↑ 2.0 2.1 Klaene and Sanders (2008), p. 13-5.
- ↑ 3.0 3.1 3.2 Granito (2008), p. 12-13.
- ↑ 4.0 4.1 Johnson and Price (2008), p. 12-217.
- ↑ 5.0 5.1 5.2 Australian Building Codes Board (2020b), p. 113.
- ↑ 6.0 6.1 6.2 National Research Council of Canada et al. (2005), p. 1.9-1.
- ↑ 7.0 7.1 7.2 Australian Building Codes Board (2022), p. 15.
- ↑ 8.0 8.1 8.2 Ministry of Business, Innovation and Employment (2025b), p. 53.
- ↑ 9.0 9.1 9.2 9.3 R. Wright (2008), p. 13-14.
- ↑ 10.0 10.1 National Research Council of Canada et al. (2005), p. 1.9-4.
- ↑ National Research Council of Canada et al. (2005), p. 1.9-5.
- ↑ 12.0 12.1 12.2 Klaene and Sanders (2008), p. 13-6.
- ↑ 13.0 13.1 13.2 13.3 13.4 13.5 Lawson and Vettori (2005), Appendix I.
- ↑ R. Wright (2008), p. 13-15.
- ↑ Schmidt (2008), p. 1-146.
- ↑ Klaene and Sanders (2008), pp. 13-6–13-7.
- ↑ 17.0 17.1 17.2 17.3 17.4 17.5 Klaene and Sanders (2008), p. 13-7.
- ↑ Klaene and Sanders (2008), p. 13-10.
- ↑ Denlinger (2008), pp. 12-63–12-64.
- ↑ Denlinger (2008), p. 12-64.
- ↑ Granito (2008), p. 12-10.
- ↑ 22.0 22.1 Granito (2008), p. 12-8.
- ↑ 23.0 23.1 Loflin (2008), p. 12-114.
- ↑ Granito (2008), p. 12-11.
- ↑ 25.0 25.1 Granito (2008), p. 12-12.
- ↑ 26.0 26.1 Purser (2002), p. 2-131.
- ↑ Hall and Cote (2008), p. 3-25.
- ↑ Watts (2008b), p. 1-167.
- ↑ Meacham and Galioto (2008), p. 1-133.
- ↑ Lawson and Vettori (2005), p. 115.
- ↑ Lawson and Vettori (2005), p. 116.
- ↑ Lawson and Vettori (2005), p. 47.
- ↑ Bryan (2002), p. 3-327.
- ↑ Ahrens et al. (2008), p. 3-86.
- ↑ Kreckie (2008), p. 13-110.
- ↑ Teele (2008), p. 12-151.
- ↑ Australian Building Codes Board (2020b), p. 87.
- ↑ 38.0 38.1 38.2 Australian Building Codes Board (2020b), p. 111.
- ↑ 39.0 39.1 Australian Building Codes Board (2020b), p. 112.
- ↑ Australian Building Codes Board (2020b), p. 110.
- ↑ 41.0 41.1 Van Rossum (2027), §9.3 (Results from zone models).
- ↑ Klaene and Sanders (2008), p. 13-3.
- ↑ Duggan (2008), p. 12-87.
- ↑ Jenaway (2008), p. 12-43.
- ↑ 45.0 45.1 45.2 National Research Council of Canada et al. (2005), p. 1.9-6.
- ↑ National Research Council of Canada et al. (2005), p. 1.9-7.
- ↑ National Research Council of Canada et al. (2005), p. 2.9-2.
- ↑ 48.0 48.1 48.2 National Research Council of Canada et al. (2005), p. 2.9-3.
- ↑ National Research Council of Canada et al. (2005), p. 2.9-5.
- ↑ National Research Council of Canada et al. (2005), p. 2.9-4.
- ↑ Australian Building Codes Board (2022), p. 16.
- ↑ Australian Building Codes Board (2020b), p. 88.
- ↑ 53.0 53.1 Ministry of Business, Innovation and Employment (2025b), p. 55.
- ↑ Ministry of Business, Innovation and Employment (2013), p. 196.
- ↑ Carino et al. (2005), p. 6.
- ↑ Van Rossum (2027), §1.2.
References
- Ahrens, M., Frazier, P., & Kelch, G. (2008). Use of fire incident data and statistics. In A. E. Cote, C. C. Grant, J. R. Hall, Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 3-61–3-92). National Fire Protection Association.
- Australian Building Codes Board. (2020b). Handbook: Fire Safety Verification Method (Print version 1.1).
- Australian Building Codes Board. (2022). Fire Safety Verification Method Standard 2022.
- Bryan, J. L. (2002). Behavioral response to fire and smoke. In P. J. DiNenno, D. Drysdale, C. L. Beyler, W. D. Walton, R. L. P. Custer, J. R. Hall Jr., & J. M. Watts Jr. (Eds.), SFPE handbook of fire protection engineering (3rd ed., pp. 3-315–3-341). National Fire Protection Association; Society of Fire Protection Engineers.
- Carino, N. J., Starnes, M. A., Gross, J. L., Yang, J. C., Kukuck, S. R., Prasad, K. R., & Bukowski, R. W. (2005). Passive fire protection (NIST NCSTAR 1-6A). National Institute of Standards and Technology.
- Denlinger, R. F. (2008). Managing fire-rescue departments. In A. E. Cote, C. C. Grant, J. R. Hall, Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 12-51–12-78). National Fire Protection Association.
- Duggan, B. P. (2008). Information management and computer technology. In A. E. Cote, C. C. Grant, J. R. Hall, Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 12-79–12-97). National Fire Protection Association.
- Granito, J. A. (2008). Planning for public fire-rescue protection. In A. E. Cote, C. C. Grant, J. R. Hall, Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 12-3–12-22). National Fire Protection Association.
- Hall, J. R., Jr., & Cote, A. E. (2008). An overview of the fire problem and fire protection. In A. E. Cote, C. C. Grant, J. R. Hall, Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 3-3–3-30). National Fire Protection Association.
- Jenaway, W. F. (2008). Needs assessment and hazard analysis. In A. E. Cote, C. C. Grant, J. R. Hall, Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 12-41–12-50). National Fire Protection Association.
- Johnson, R., & Price, M. (2008). GIS for fire station locations and response protocols. In A. E. Cote, C. C. Grant, J. R. Hall, Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 12-215–12-231). National Fire Protection Association.
- Klaene, B. J., & Sanders, R. (2008). Fireground operations. In A. E. Cote, C. C. Grant, J. R. Hall, Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 13-3–13-11). National Fire Protection Association.
- Kreckie, J. (2008). Aircraft rescue and fire fighting (ARFF). In A. E. Cote, C. C. Grant, J. R. Hall, Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 13-99–13-115). National Fire Protection Association.
- Lawson, J. R., & Vettori, R. L. (2005). The emergency response operations (NIST NCSTAR 1-8). National Institute of Standards and Technology.
- Loflin, M. E. (2008). Safety, medical, and health issues and programs. In A. E. Cote, C. C. Grant, J. R. Hall, Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 12-107–12-125). National Fire Protection Association.
- Meacham, B. J., & Galioto, C. (2008). Protecting against extreme events. In A. E. Cote, C. C. Grant, J. R. Hall, Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 1-109–1-136). National Fire Protection Association.
- Ministry of Business, Innovation and Employment. (2013). Commentary for Building Code clauses C1–C6 and Verification Method C/VM2.
- Ministry of Business, Innovation and Employment. (2025b). Verification Method C/VM2: Framework for fire safety design (2nd ed.).
- National Research Council of Canada, International Code Council, Department of Building and Housing, & Australian Building Codes Board. (2005). International fire engineering guidelines (2005 ed.). Australian Building Codes Board.
- Purser, D. A. (2002). Toxicity assessment of combustion products. In P. J. DiNenno, D. Drysdale, C. L. Beyler, W. D. Walton, R. L. P. Custer, J. R. Hall Jr., & J. M. Watts Jr. (Eds.), SFPE handbook of fire protection engineering (3rd ed., pp. 2-83–2-171). National Fire Protection Association; Society of Fire Protection Engineers.
- Schmidt, D. L. (2008). Emergency management and business continuity. In A. E. Cote, C. C. Grant, J. R. Hall, Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 1-137–1-156). National Fire Protection Association.
- Teele, B. W. (2008). Fire and emergency services protective clothing and protective equipment. In A. E. Cote, C. C. Grant, J. R. Hall, Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 12-143–12-160). National Fire Protection Association.
- Van Rossum, E. (2027). Introduction to Fire Safety Engineering. Fire Safety Academy.
- Watts, J. M., Jr. (2008b). Systems approach to fire-safe building design. In A. E. Cote, C. C. Grant, J. R. Hall, Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 1-157–1-170). National Fire Protection Association.
- Wright, R. (2008). Organizing rescue operations. In A. E. Cote, C. C. Grant, J. R. Hall, Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 13-13–13-21). National Fire Protection Association.