Add SVG figures fse-recreational-vehicle-fire-v1.svg, fse-recreational-vehicle-fire-v2.svg, fse-recreational-vehicle-fire-v3.svg, fse-recreational-vehicle-fire-v4.svg (list-3 visual plan) |
m Remove source references from image captions |
||
| Line 7: | Line 7: | ||
Motor homes are divided into three types. A Type A motor home is generally the largest, and its driving compartment is built by the RV manufacturer.<ref name="Hopkins-21-91" /> A Type B motor home, or van camper, is the smallest and is built inside a van whose shell comes from the chassis manufacturer. A Type C motor home has a cab supplied by the chassis manufacturer and falls in between in size. Type A motor homes sleep 2 to 6 people, Type B 2 to 4 and Type C 6 to 10.<ref name="Hopkins-21-93">Hopkins (2008), p. 21-93.</ref> | Motor homes are divided into three types. A Type A motor home is generally the largest, and its driving compartment is built by the RV manufacturer.<ref name="Hopkins-21-91" /> A Type B motor home, or van camper, is the smallest and is built inside a van whose shell comes from the chassis manufacturer. A Type C motor home has a cab supplied by the chassis manufacturer and falls in between in size. Type A motor homes sleep 2 to 6 people, Type B 2 to 4 and Type C 6 to 10.<ref name="Hopkins-21-93">Hopkins (2008), p. 21-93.</ref> | ||
[[File:fse-recreational-vehicle-fire-v1.svg|thumb|upright=1.5|alt=Side-view silhouettes of Type A, B and C motor homes, four towable RV types and a camper mounted on a pickup truck|Main types of recreational vehicles in the United States, with typical sleeping capacity | [[File:fse-recreational-vehicle-fire-v1.svg|thumb|upright=1.5|alt=Side-view silhouettes of Type A, B and C motor homes, four towable RV types and a camper mounted on a pickup truck|Main types of recreational vehicles in the United States, with typical sleeping capacity.]] | ||
A towable RV is designed to be towed by a car, van or pickup truck without a special highway permit, and it needs no permanent connection on site.<ref name="Hopkins-21-92">Hopkins (2008), p. 21-92.</ref> A conventional travel trailer is 3.66 to 10.67 m (12–35 ft) long and sleeps 4 to 8 people.<ref name="Hopkins-21-93" /> Sport utility RVs contain a built-in garage for motorcycles, all-terrain vehicles or other sports equipment. | A towable RV is designed to be towed by a car, van or pickup truck without a special highway permit, and it needs no permanent connection on site.<ref name="Hopkins-21-92">Hopkins (2008), p. 21-92.</ref> A conventional travel trailer is 3.66 to 10.67 m (12–35 ft) long and sleeps 4 to 8 people.<ref name="Hopkins-21-93" /> Sport utility RVs contain a built-in garage for motorcycles, all-terrain vehicles or other sports equipment. | ||
| Line 33: | Line 33: | ||
Several changes from the 1993 edition onwards may explain fewer RV fire deaths, according to the handbook author.<ref name="Hopkins-21-99" /> The minimum portable extinguisher for towable RVs was raised from 4B:C to 5B:C, and motorised RVs were required to carry a 10B:C extinguisher. [[Carbon monoxide]] detectors were required in RVs with an internal combustion engine or features for installing one later; propane detectors were required in RVs with propane appliances and a 120 V AC system. Emergency exits were enlarged and marked, and propane containers had to be shielded from exhaust parts and other hot surfaces. | Several changes from the 1993 edition onwards may explain fewer RV fire deaths, according to the handbook author.<ref name="Hopkins-21-99" /> The minimum portable extinguisher for towable RVs was raised from 4B:C to 5B:C, and motorised RVs were required to carry a 10B:C extinguisher. [[Carbon monoxide]] detectors were required in RVs with an internal combustion engine or features for installing one later; propane detectors were required in RVs with propane appliances and a 120 V AC system. Emergency exits were enlarged and marked, and propane containers had to be shielded from exhaust parts and other hot surfaces. | ||
[[File:fse-recreational-vehicle-fire-v2.svg|thumb|upright=1.5|alt=Cutaway of a motor home with historical smoke, CO, propane, extinguisher, exit and electrical provisions, plus a separate transport-area inset|Selected US recreational-vehicle fire and life safety provisions described in the 2008 handbook | [[File:fse-recreational-vehicle-fire-v2.svg|thumb|upright=1.5|alt=Cutaway of a motor home with historical smoke, CO, propane, extinguisher, exit and electrical provisions, plus a separate transport-area inset|Selected US recreational-vehicle fire and life safety provisions described in the 2008 handbook.]] | ||
The electrical changes described in the 2008 handbook were equally specific. Low-voltage wiring was required to have an insulation rating of at least 90 °C for interior use and 125 °C in an engine area.<ref name="Hopkins-21-99" /> A 30 A power supply could serve at most five branch circuits, and an RV could have only one power supply assembly. Low-voltage light fittings had to be listed to limit heat build-up at their mounting surfaces, and countertop sockets near sinks needed ground-fault circuit interrupters. | The electrical changes described in the 2008 handbook were equally specific. Low-voltage wiring was required to have an insulation rating of at least 90 °C for interior use and 125 °C in an engine area.<ref name="Hopkins-21-99" /> A 30 A power supply could serve at most five branch circuits, and an RV could have only one power supply assembly. Low-voltage light fittings had to be listed to limit heat build-up at their mounting surfaces, and countertop sockets near sinks needed ground-fault circuit interrupters. | ||
| Line 65: | Line 65: | ||
As a worked example, assume that exhaust from an engine or generator keeps the CO level in a closed RV at 400 ppm. This is a hypothetical constant concentration, not a measured RV fire scenario. The starting COHb of a non-smoker can be taken as 0.8%.<ref name="Purser-2-164">Purser (2002), p. 2-164.</ref> With ''B'' = 0.0404, the time constant 2398''B'' is 96.9 minutes. After 30 minutes the equation gives about 18% COHb, within the cited range for a headache, and after 60 minutes about 31%, a level at which incapacitation is possible during activity.<ref name="Black-14-114" /><ref name="Purser-2-100" /><ref name="Purser-2-101" /> The calculated 30% crossing occurs after about 57 minutes under these assumptions. | As a worked example, assume that exhaust from an engine or generator keeps the CO level in a closed RV at 400 ppm. This is a hypothetical constant concentration, not a measured RV fire scenario. The starting COHb of a non-smoker can be taken as 0.8%.<ref name="Purser-2-164">Purser (2002), p. 2-164.</ref> With ''B'' = 0.0404, the time constant 2398''B'' is 96.9 minutes. After 30 minutes the equation gives about 18% COHb, within the cited range for a headache, and after 60 minutes about 31%, a level at which incapacitation is possible during activity.<ref name="Black-14-114" /><ref name="Purser-2-100" /><ref name="Purser-2-101" /> The calculated 30% crossing occurs after about 57 minutes under these assumptions. | ||
[[File:fse-recreational-vehicle-fire-v3.svg|thumb|upright=1.5|alt=Line chart of carboxyhaemoglobin rising over four hours at 200 and 400 ppm carbon monoxide, with threshold bands for headache, incapacitation and death|Estimated carboxyhaemoglobin in the blood during exposure to 200 and 400 ppm carbon monoxide, with effect levels | [[File:fse-recreational-vehicle-fire-v3.svg|thumb|upright=1.5|alt=Line chart of carboxyhaemoglobin rising over four hours at 200 and 400 ppm carbon monoxide, with threshold bands for headache, incapacitation and death|Estimated carboxyhaemoglobin in the blood during exposure to 200 and 400 ppm carbon monoxide, with effect levels.]] | ||
The model result is approximate and is not an exposure limit. The handbook's separate US symptom table for healthy adults lists headache and nausea after 1–2 hours at 400 ppm, without a precise incapacitation time.<ref name="Black-14-114" /> At concentrations above about 600 ppm and long exposures, the equation even predicts COHb levels above 100%, which is physically impossible. NFPA 720 (2005) gives separate dwelling-unit guidance to place CO alarms outside each sleeping area, on a wall or ceiling, because CO mixes readily with air; it does not itself require installation.<ref name="Black-14-115">Black (2008), p. 14-115.</ref> The handbook describes a [[Carbon monoxide alarm|carbon monoxide alarm]] signal with a distinct temporal 4 pattern and an occupant response that includes opening windows, assessing occupants and calling for emergency help when needed.<ref name="Black-14-116">Black (2008), p. 14-116.</ref> | The model result is approximate and is not an exposure limit. The handbook's separate US symptom table for healthy adults lists headache and nausea after 1–2 hours at 400 ppm, without a precise incapacitation time.<ref name="Black-14-114" /> At concentrations above about 600 ppm and long exposures, the equation even predicts COHb levels above 100%, which is physically impossible. NFPA 720 (2005) gives separate dwelling-unit guidance to place CO alarms outside each sleeping area, on a wall or ceiling, because CO mixes readily with air; it does not itself require installation.<ref name="Black-14-115">Black (2008), p. 14-115.</ref> The handbook describes a [[Carbon monoxide alarm|carbon monoxide alarm]] signal with a distinct temporal 4 pattern and an occupant response that includes opening windows, assessing occupants and calling for emergency help when needed.<ref name="Black-14-116">Black (2008), p. 14-116.</ref> | ||
| Line 78: | Line 78: | ||
For fire fighters, the propane system shapes the response. Apparatus is placed upwind, because propane vapour stays heavier than air and can travel a long way downwind.<ref name="Rivkin-21-74">Rivkin (2008b), p. 21-74.</ref> For propane-fuelled vehicles, the handbook adds that water streams can control the fire and disperse the vapour, and that the main shutoff valve of the container is closed where possible. A burning gas leak is left to burn until the flow is stopped, because putting out the flame could let unburned gas accumulate and explode later.<ref name="Routhier-21-23" /> Fire-exposed containers are kept cool with water, while water on a pool of liquid gas is avoided because it increases the rate of evaporation.<ref name="Lemoff-6-184" /> | For fire fighters, the propane system shapes the response. Apparatus is placed upwind, because propane vapour stays heavier than air and can travel a long way downwind.<ref name="Rivkin-21-74">Rivkin (2008b), p. 21-74.</ref> For propane-fuelled vehicles, the handbook adds that water streams can control the fire and disperse the vapour, and that the main shutoff valve of the container is closed where possible. A burning gas leak is left to burn until the flow is stopped, because putting out the flame could let unburned gas accumulate and explode later.<ref name="Routhier-21-23" /> Fire-exposed containers are kept cool with water, while water on a pool of liquid gas is avoided because it increases the rate of evaporation.<ref name="Lemoff-6-184" /> | ||
[[File:fse-recreational-vehicle-fire-v4.svg|thumb|upright=1.5|alt=Side view of a travel trailer with a liquid propane release forming visible fog while the ignitable vapour cloud extends further downwind, and a fire engine upwind|Behaviour of leaking propane vapour and basic positioning at an RV fire | [[File:fse-recreational-vehicle-fire-v4.svg|thumb|upright=1.5|alt=Side view of a travel trailer with a liquid propane release forming visible fog while the ignitable vapour cloud extends further downwind, and a fire engine upwind|Behaviour of leaking propane vapour and basic positioning at an RV fire.]] | ||
== See also == | == See also == | ||
Latest revision as of 08:34, 13 November 2026
A recreational vehicle fire is a fire in a recreational vehicle (RV), such as a motor home, caravan (travel trailer), folding camping trailer or truck camper. An RV is a vehicle that combines transportation with temporary living quarters for travel, recreation and camping.[1] It therefore carries the hazards of a road vehicle, described in Motor vehicle fire, together with those of a small dwelling.
Many RVs contain propane appliances for cooking and heating, a 120 V AC electrical system, sleeping places and combustible interior finishes.[2] The 2008 US handbook describes NFPA 1192, Standard on Recreational Vehicles, as the standard setting minimum RV fire and life safety provisions.[3] Its account includes portable fire extinguishers. Since the 1990s, it also describes propane detectors for RVs with propane appliances and a 120 V AC system, and carbon monoxide detectors for RVs with an internal combustion engine or provisions for one.[2] RV standards have addressed smoke alarms since the first fire safety provisions of 1982.[4] Nearly 8 million US households owned an RV around 2005, but reliable fire statistics for RVs are scarce, because RV fires are often recorded as fires in mobile homes or under brand names.[2]
Definition and types
The definition used in NFPA 1192, as refined by the Recreation Vehicle Industry Association (RVIA), covers three forms.[1] Motor homes have their own motor power, truck campers are mounted on a truck, and travel trailers, fifth-wheel trailers and folding camping trailers are towed by another vehicle. Conversion vehicles, off-road vehicles, emergency living units and manufactured housing for long-term residence, such as park trailers and mobile homes, are not RVs under this definition.
Motor homes are divided into three types. A Type A motor home is generally the largest, and its driving compartment is built by the RV manufacturer.[1] A Type B motor home, or van camper, is the smallest and is built inside a van whose shell comes from the chassis manufacturer. A Type C motor home has a cab supplied by the chassis manufacturer and falls in between in size. Type A motor homes sleep 2 to 6 people, Type B 2 to 4 and Type C 6 to 10.[5]
A towable RV is designed to be towed by a car, van or pickup truck without a special highway permit, and it needs no permanent connection on site.[6] A conventional travel trailer is 3.66 to 10.67 m (12–35 ft) long and sleeps 4 to 8 people.[5] Sport utility RVs contain a built-in garage for motorcycles, all-terrain vehicles or other sports equipment.
The RV differs from a Manufactured home, although the two share a history and were long covered by the same NFPA standards. US manufactured homes are built to the federal HUD Code and placed on piers, footings or a permanent foundation.[7] Their sections are typically 2.5 m (8 ft) or more wide and 12.2 to 24.4 m (40–80 ft) long. In US fire statistics, a fire in a motor home, camper or RV used as a fixed structure is coded as a structure fire.[8] A fire in an RV on the road falls among the vehicle fires.
Growth and use
RVs have existed since the beginning of motor travel in the early 1900s.[1] In the late 1940s and early 1950s, portable propane or butane cylinders allowed gas stoves and heaters to replace liquid-fuelled models.[9] Refrigerators, running hot water, toilets, showers and 110 V generators followed. With these comforts came concerns about the safe installation of plumbing, gas and electrical systems, and California introduced RV safety standards in the late 1950s.
The vehicles also grew larger. From the 1930s to the early 1960s, most units were shorter than 6.1 m (20 ft); the 2008 handbook describes 9.14 to 12.19 m (30–40 ft) units as common in its period.[4] From the early 1980s, larger rigs offered living rooms, air-conditioning and other comforts of a home. Some retirees and families sold their houses and lived on the road full time, so an RV may be a permanent dwelling for some of its users. By about 2005, nearly 8 million US households, or one in twelve vehicle-owning households, owned at least one RV.[4] About 8.2 million RVs were on US roads, and annual shipments rose from 259,200 in 1994 to 390,500 in 2006, an increase of about half.[10]
Fire hazards
The main fire hazards of an RV come from its fuels, its electrical system and its interior. Motor homes with combustion engines carry petrol or diesel, and NFPA 1192 as described by the 2008 handbook contains separate provisions for these fuel systems and for propane engines.[3] Many RVs also carry liquefied petroleum gas (propane) for appliances, and gas-fired heaters are popular in RVs.[11]
Liquefied petroleum gas vapour is about 1.5 times as heavy as air and tends to spread along the floor or ground. When escaping liquid creates a visible fog, the ignitable mixture can extend beyond it.[12] The gas is odorised so that it can be smelled at less than one fifth of its lower flammable limit. Odorants can fade, however, and the sense of smell weakens with age.[13]
In vehicles that use it as engine fuel, propane is stored as a liquid at about 827 to 1,379 kPa (120–200 psig).[14] A gas container exposed to flames can weaken and rupture. The handbook advises cooling such a container to avoid a BLEVE, a boiling liquid expanding vapour explosion, and leaving the area at once if no hose streams are available.[15] At a road accident involving a travel trailer or motor home, the handbook advises responders to consider propane likely, prohibit smoking and keep open flames and lights well away.[16]
The electrical system adds a second group of hazards. An RV combines a low-voltage vehicle system with a 120 V AC system, supplied through a power supply assembly or by a generator.[2] NFPA 1192 therefore sets minimum insulation ratings for low-voltage wiring and limits the number of branch circuits on a 30 A supply. Heating appliances that burn liquid fuel or gas have their own UL standards, UL 307(a) and UL 307(b), for mobile homes and RVs.[17] RVs also offer little shelter in thunderstorms. Enclosed vehicles with metal tops and bodies protect their occupants against lightning, but RVs that are open or not made of metal offer little or no protection.[18]
The interior combines kitchen, sleeping and bathroom facilities within one vehicle.[1] RV standards that preceded NFPA 1192 added provisions for interior finishes and textile and film materials in 1982.[4] NFPA 1192, as described in 2008, uses the ASTM E162 radiant panel test for cabinet door and drawer faces, exposed cabinet bottoms and end panels, and tub and shower walls. A radiant panel index of 200 is specified for these surfaces.[19] Sport utility RVs can carry motorcycles or all-terrain vehicles with internal combustion engines inside, so the 2008 handbook describes a requirement for a ventilated transport area with a vapour-tight separation from the living area.[2]
Standards and fire safety measures
NFPA work on trailers began with a Committee on Trailers and Trailer Camps in 1937.[10] The handbook describes a 1939 standard for trailer camps followed by a 1940 standard for trailer coaches and trailer coach camps. The first Standard for Recreational Vehicles, NFPA 501C, appeared in 1970 and defined motor homes, travel trailers, camping trailers and truck campers.[4] Fire safety requirements were first added in 1982, covering interior finish, textile and film flammability, exits, fire detection equipment and smoke alarms. From 1987 to 2005 the standard was updated every three years.[4] It was renumbered NFPA 1192 in 1999, and in 2005 the requirements of the separate ANSI A119.2 standard were merged into it.[3]
Several changes from the 1993 edition onwards may explain fewer RV fire deaths, according to the handbook author.[2] The minimum portable extinguisher for towable RVs was raised from 4B:C to 5B:C, and motorised RVs were required to carry a 10B:C extinguisher. Carbon monoxide detectors were required in RVs with an internal combustion engine or features for installing one later; propane detectors were required in RVs with propane appliances and a 120 V AC system. Emergency exits were enlarged and marked, and propane containers had to be shielded from exhaust parts and other hot surfaces.
The electrical changes described in the 2008 handbook were equally specific. Low-voltage wiring was required to have an insulation rating of at least 90 °C for interior use and 125 °C in an engine area.[2] A 30 A power supply could serve at most five branch circuits, and an RV could have only one power supply assembly. Low-voltage light fittings had to be listed to limit heat build-up at their mounting surfaces, and countertop sockets near sinks needed ground-fault circuit interrupters.
The 2008 handbook describes RV industry compliance and oversight. At the time, the RVIA represented more than 550 manufacturers and suppliers producing about 98% of RVs and conversion vehicles built in the United States.[2] The RVIA seal indicated a manufacturer's certification of compliance with more than 500 electrical, plumbing, heating and fire and life safety requirements of NFPA 1192, and members were subject to unannounced plant inspections. The handbook describes the separate state and federal programmes as self-certification schemes without oversight by an outside agency; manufacturers had to report safety defects and usually recall the affected vehicles. NFPA 1194 addressed RV parks and campgrounds, including fire detection and alarm services, posted emergency information and provisions for wildland/urban interface areas.[3]
Smoke alarms and carbon monoxide
Smoke alarms are the basic fire warning device in homes, and the RV standards that became NFPA 1192 have addressed them since 1982.[20][4] Residential detection ranges from one single-station smoke alarm in an apartment, manufactured home or RV to large wired systems.[21] In US homes, having smoke detectors present cuts the chance of dying in a fire nearly in half.[20] About one third of US home smoke alarms, however, did not work when a fire occurred in the NFPA analysis cited in 2008, usually because of dead or missing batteries.[21]
Carbon monoxide (CO) is a colourless and odourless gas produced by incomplete combustion.[22] When inhaled, it binds to haemoglobin in the blood and reduces its oxygen-carrying capacity, forming carboxyhaemoglobin (COHb). Sources include improperly operating heating appliances, blocked or missing vents, idling vehicles in attached garages and portable equipment such as generators. In fires, CO is the most important asphyxiant: in one pathology study, 69% of fire fatalities had COHb levels that can cause incapacitation, at or above 30%.[23] Loss of consciousness is predicted at about 40% COHb, but can occur from 30%, and death at 50 to 70%. In the cited human exposure studies, headache first appeared at about 15–20% COHb.[24]
The effect of CO depends on the dose, the product of concentration and time.[25] Far from a fire, CO concentrations can be very high even where visibility exceeds 20 m. US guidance gives approximate effects for healthy adults. At 200 ppm, a mild headache follows after 2–3 hours; 400 ppm causes headache and nausea after 1–2 hours, and 1,000 ppm loss of consciousness after 1 hour.[26] Children, the elderly and people with heart or lung disease can be affected at lower levels.
The COHb level after a given exposure can be estimated with an uptake equation from the annex of NFPA 720. It combines the initial COHb level, which decays over time, with a growing term that depends on the CO concentration in the air.[26] The time constant depends on a factor B for work effort.
| Symbol | Description | Unit |
|---|---|---|
| Carboxyhaemoglobin in the blood at time t | % | |
| Carboxyhaemoglobin at the start of the exposure | % | |
| Exposure time | min | |
| Factor for work effort, 0.0404 | – | |
| Carbon monoxide concentration in the air | ppm |
As a worked example, assume that exhaust from an engine or generator keeps the CO level in a closed RV at 400 ppm. This is a hypothetical constant concentration, not a measured RV fire scenario. The starting COHb of a non-smoker can be taken as 0.8%.[27] With B = 0.0404, the time constant 2398B is 96.9 minutes. After 30 minutes the equation gives about 18% COHb, within the cited range for a headache, and after 60 minutes about 31%, a level at which incapacitation is possible during activity.[26][23][24] The calculated 30% crossing occurs after about 57 minutes under these assumptions.
The model result is approximate and is not an exposure limit. The handbook's separate US symptom table for healthy adults lists headache and nausea after 1–2 hours at 400 ppm, without a precise incapacitation time.[26] At concentrations above about 600 ppm and long exposures, the equation even predicts COHb levels above 100%, which is physically impossible. NFPA 720 (2005) gives separate dwelling-unit guidance to place CO alarms outside each sleeping area, on a wall or ceiling, because CO mixes readily with air; it does not itself require installation.[28] The handbook describes a carbon monoxide alarm signal with a distinct temporal 4 pattern and an occupant response that includes opening windows, assessing occupants and calling for emergency help when needed.[29]
Fire statistics and data limits
The handbook reports that deaths from fire in RVs fell between 1993 and 2002, but gives no numbers.[2] The reasons are difficult to determine, because records are limited and police accident reports classify RVs inconsistently. RVs are sometimes reported as mobile homes or manufactured homes, and motor homes and trailers are often listed under brand names such as Airstream or Winnebago. All-terrain vehicles and dune buggies are also sometimes recorded as RVs, which further distorts the data.
National vehicle fire analyses do not always treat RVs the same way. One handbook analysis of passenger vehicle fires excluded off-road recreational vehicles and trailers, while an NFPA report on the same subject included them.[30] Because an RV used as a fixed structure is coded as a structure fire, its fires can also appear in the building statistics.[8] The source documents contain no heat release rate measurements or full-scale fire tests of motor homes or caravans.
Response
The handbook steps for any vehicle fire also apply to RVs. The engine, if present, and electrical systems are shut off, everyone is moved well away, preferably uphill and upwind, and the fire department is called.[16] A fire is fought only if this can be done without danger. The 2008 handbook reports that many people kept extinguishers in vans and motor homes, and describes an NFPA 1192 requirement for them in RVs.[2]
For fire fighters, the propane system shapes the response. Apparatus is placed upwind, because propane vapour stays heavier than air and can travel a long way downwind.[31] For propane-fuelled vehicles, the handbook adds that water streams can control the fire and disperse the vapour, and that the main shutoff valve of the container is closed where possible. A burning gas leak is left to burn until the flow is stopped, because putting out the flame could let unburned gas accumulate and explode later.[15] Fire-exposed containers are kept cool with water, while water on a pool of liquid gas is avoided because it increases the rate of evaporation.[12]
See also
Notes
- ↑ 1.0 1.1 1.2 1.3 1.4 Hopkins (2008), p. 21-91.
- ↑ 2.00 2.01 2.02 2.03 2.04 2.05 2.06 2.07 2.08 2.09 Hopkins (2008), p. 21-99.
- ↑ 3.0 3.1 3.2 3.3 Hopkins (2008), p. 21-98.
- ↑ 4.0 4.1 4.2 4.3 4.4 4.5 4.6 Hopkins (2008), p. 21-96.
- ↑ 5.0 5.1 Hopkins (2008), p. 21-93.
- ↑ Hopkins (2008), p. 21-92.
- ↑ Paoletti (2008), pp. 20-63–20-64.
- ↑ 8.0 8.1 Ahrens et al. (2008), p. 3-67.
- ↑ Hopkins (2008), pp. 21-95–21-96.
- ↑ 10.0 10.1 Hopkins (2008), p. 21-97.
- ↑ Gore Willse (2008a), p. 10-16.
- ↑ 12.0 12.1 Lemoff (2008), p. 6-184.
- ↑ Rivkin (2008b), p. 21-60.
- ↑ Rivkin (2008b), p. 21-72.
- ↑ 15.0 15.1 Routhier (2008), p. 21-23.
- ↑ 16.0 16.1 Routhier (2008), p. 21-22.
- ↑ Routhier (2008), p. 21-19.
- ↑ Caloggero (2008), p. 11-80.
- ↑ Hirschler (2008b), p. 18-32.
- ↑ 20.0 20.1 Gottuk (2008), p. 14-79.
- ↑ 21.0 21.1 Gottuk (2008), p. 14-81.
- ↑ Black (2008), p. 14-113.
- ↑ 23.0 23.1 Purser (2002), p. 2-100.
- ↑ 24.0 24.1 Purser (2002), p. 2-101.
- ↑ Van Rossum (2027), §6.1.
- ↑ 26.0 26.1 26.2 26.3 Black (2008), p. 14-114.
- ↑ Purser (2002), p. 2-164.
- ↑ Black (2008), p. 14-115.
- ↑ Black (2008), p. 14-116.
- ↑ Long et al. (2008), p. 21-5.
- ↑ Rivkin (2008b), p. 21-74.
References
- Ahrens, M., Frazier, P., & Kelch, G. (2008). Use of fire incident data and statistics. In A. E. Cote, C. C. Grant, J. R. Hall Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 3-61–3-92). National Fire Protection Association.
- Black, A. (2008). Carbon monoxide detection in residential occupancies. In A. E. Cote, C. C. Grant, J. R. Hall Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 14-113–14-117). National Fire Protection Association.
- Caloggero, J. M. (2008). Lightning protection systems. In A. E. Cote, C. C. Grant, J. R. Hall Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 11-69–11-81). National Fire Protection Association.
- Gore Willse, P. J. (2008a). Heating systems and appliances. In A. E. Cote, C. C. Grant, J. R. Hall Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 10-9–10-56). National Fire Protection Association.
- Gottuk, D. T. (2008). Household fire-warning equipment. In A. E. Cote, C. C. Grant, J. R. Hall Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 14-79–14-87). National Fire Protection Association.
- Hirschler, M. M. (2008b). Interior finish. In A. E. Cote, C. C. Grant, J. R. Hall Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 18-23–18-42). National Fire Protection Association.
- Hopkins, B. A. (2008). Recreational vehicles. In A. E. Cote, C. C. Grant, J. R. Hall Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 21-91–21-100). National Fire Protection Association.
- Lemoff, T. C. (2008). Gases. In A. E. Cote, C. C. Grant, J. R. Hall Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 6-165–6-186). National Fire Protection Association.
- Long, R. T., Jr., Colwell, J. D., Ray, R., Grossman, H. L., Thomas, B., & Strassburger, R. (2008). Passenger vehicle fires. In A. E. Cote, C. C. Grant, J. R. Hall Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 21-3–21-14). National Fire Protection Association.
- Paoletti, K. M. (2008). Manufactured housing. In A. E. Cote, C. C. Grant, J. R. Hall Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 20-63–20-71). National Fire Protection Association.
- Purser, D. A. (2002). Toxicity assessment of combustion products. In P. J. DiNenno, D. Drysdale, C. L. Beyler, W. D. Walton, R. L. P. Custer, J. R. Hall Jr., & J. M. Watts Jr. (Eds.), SFPE handbook of fire protection engineering (3rd ed., pp. 2-83–2-171). National Fire Protection Association; Society of Fire Protection Engineers.
- Rivkin, C. H. (2008b). Vehicle fueling using gaseous fuels. In A. E. Cote, C. C. Grant, J. R. Hall Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 21-41–21-76). National Fire Protection Association.
- Routhier, B. (2008). Fire safety in commercial vehicles. In A. E. Cote, C. C. Grant, J. R. Hall Jr., & R. E. Solomon (Eds.), Fire protection handbook (20th ed., pp. 21-15–21-27). National Fire Protection Association.
- Van Rossum, E. (2027). Introduction to Fire Safety Engineering. Fire Safety Academy.