CBUF rule for mattresses: a fire is predicted to be nonpropagating (below 80 kW) when the 180 s cone average multiplied by the thickness factor is below 100 kW/m² and q″60 is below 250 kW/m². Points show eight CBUF mattresses with their measured furniture calorimeter peaks. Based on Babrauskas (2002b), p. 3-22.
CBUF rule for mattresses: a fire is predicted to be nonpropagating (below 80 kW) when the 180 s cone average multiplied by the thickness factor is below 100 kW/m² and q″60 is below 250 kW/m². Points show eight CBUF mattresses with their measured furniture calorimeter peaks.


Original illustration for [[Mattress flammability]].
Original illustration for [[Mattress flammability]].


* Source basis: Babrauskas (2002b), p. 3-22 (rule and Table 3-1.10); new chart, not a copied figure
* Alt text: CBUF mattress results: thickness-adjusted 180 s average against q″60, with nonpropagating limits of 100 and 250 kW/m².
* Alt text: CBUF mattress results: thickness-adjusted 180 s average against q″60, with nonpropagating limits of 100 and 250 kW/m².


== Licensing ==
== Licensing ==
New drawing by Fire Safety Academy. © Fire Safety Academy.
New drawing by Fire Safety Academy. © Fire Safety Academy.

Latest revision as of 08:34, 8 November 2026

Summary

CBUF rule for mattresses: a fire is predicted to be nonpropagating (below 80 kW) when the 180 s cone average multiplied by the thickness factor is below 100 kW/m² and q″60 is below 250 kW/m². Points show eight CBUF mattresses with their measured furniture calorimeter peaks.

Original illustration for Mattress flammability.

  • Alt text: CBUF mattress results: thickness-adjusted 180 s average against q″60, with nonpropagating limits of 100 and 250 kW/m².

Licensing

New drawing by Fire Safety Academy. © Fire Safety Academy.

File history

Click on a date/time to view the file as it appeared at that time.

Date/TimeThumbnailDimensionsUserComment
current08:34, 8 November 2026Thumbnail for version as of 08:34, 8 November 20261,220 × 825 (10 KB)Lisa (talk | contribs)Watermark: Fire Safety Academy logo icon, 70 px, 45 % opacity
07:55, 8 November 2026Thumbnail for version as of 07:55, 8 November 20261,220 × 825 (10 KB)Lisa (talk | contribs)Watermark: Fire Safety Academy logo icon, 70 px, 45 % opacity

The following page uses this file:

Metadata