	<entry>
		<id>https://fire-safety.academy/w/index.php?title=Single_Burning_Item_test&amp;diff=9679&amp;oldid=prev</id>
		<title>Mark: New FSE wiki article: Single Burning Item test (written by GPT-6)</title>
		<link rel="alternate" type="text/html" href="https://fire-safety.academy/w/index.php?title=Single_Burning_Item_test&amp;diff=9679&amp;oldid=prev"/>
		<updated>2026-11-23T19:12:24Z</updated>

		<summary type="html">&lt;p&gt;New FSE wiki article: Single Burning Item test (written by GPT-6)&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;The &amp;#039;&amp;#039;&amp;#039;Single Burning Item test&amp;#039;&amp;#039;&amp;#039; (&amp;#039;&amp;#039;&amp;#039;SBI test&amp;#039;&amp;#039;&amp;#039;) measures how a construction product contributes to a developing fire when a burner exposes two upright specimen wings arranged in a corner. The European method, EN 13823, uses the same exposure for each specimen so that products can be compared. The burner represents a single burning object near the corner. The product forms the surfaces on which fire may grow.&amp;lt;ref name=&amp;quot;sbi&amp;quot;&amp;gt;Hirschler (2008), §6.3, pp. 6-48–6-49.&amp;lt;/ref&amp;gt;&amp;lt;ref name=&amp;quot;sbiro&amp;quot;&amp;gt;Babrauskas (2002), ch. 3-1, pp. 3-32–3-33, Table 3-1.17.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
The test contributes to the European [[Euroclass system|classification of construction products]]. It measures [[Reaction to fire|reaction to fire]], including heat and smoke production during the exposure. A reader interpreting a result needs the time history, the observations of flame spread and the product configuration. A fire-resistance period for a wall or floor answers a separate question.&amp;lt;ref name=&amp;quot;sbi&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;sbiclass&amp;quot;&amp;gt;Hirschler (2008), §6.3, Table 6.3.6, p. 6-52.&amp;lt;/ref&amp;gt;&amp;lt;ref name=&amp;quot;sbisand&amp;quot;&amp;gt;Madrzykowski and Stroup (2008), §2.3, p. 2-40.&amp;lt;/ref&amp;gt;&lt;br /&gt;
[[File:fse-single-burning-item-test-v1.svg|thumb|upright=1.5|alt=Two upright wings, both 1.5 m high, meet at a corner. Their widths are 1.0 m and 0.5 m, with a burner at the base.|The two wings expose the product to a common burner at the base of a corner. Based on Hirschler (2008), §6.3, pp. 6-48–6-49.]]&lt;br /&gt;
&lt;br /&gt;
== The corner and the exhaust hood ==&lt;br /&gt;
Both wings are 1.5 m high. The long wing is 1.0 m wide and the short wing 0.5 m wide. A triangular propane burner at their base supplies about 30 kW. A hood above the corner collects the gases for measurement. The [[Oxygen consumption principle|oxygen consumption principle]] relates the oxygen consumed in combustion to the heat released.&amp;lt;ref name=&amp;quot;sbi&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;sbisand&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;sbiro&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== What the results describe ==&lt;br /&gt;
The fire growth rate index (FIGRA) describes how quickly the specimen develops heat release. A high heat output reached early can produce a higher index than the same output reached later. The smoke growth rate index (SMOGRA) applies a related time-dependent measure to smoke production. The report also records lateral flame spread and flaming droplets or particles.&amp;lt;ref name=&amp;quot;sbi&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;sbiclass&amp;quot; /&amp;gt;&lt;br /&gt;
[[File:fse-single-burning-item-test-v2.svg|thumb|upright=1.5|alt=Three rows connect heat, smoke and visual observations to the corresponding indices and reported outcomes.|Heat release, smoke production and visual observations give complementary information about a product. Based on Hirschler (2008), §6.3, pp. 6-48–6-49.]]&lt;br /&gt;
&lt;br /&gt;
== Reading a total heat release value ==&lt;br /&gt;
Total heat release over 600 seconds, written THR&amp;lt;sub&amp;gt;600&amp;lt;/sub&amp;gt;, is an energy. It adds up the product’s contribution during that interval. The historical classification table reproduced by Hirschler gives 7.5 MJ as one of several criteria for class B. Its equivalent mean heat release rate over that interval is calculated by dividing energy by time.&amp;lt;ref name=&amp;quot;sbiclass&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;sbisand&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;math display=&amp;quot;block&amp;quot;&amp;gt;\overline{\dot Q}=\frac{E}{t}=\frac{7{,}500\ \mathrm{kJ}}{600\ \mathrm{s}}=12.5\ \mathrm{kW}&amp;lt;/math&amp;gt;&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
! Symbol !! Meaning !! Unit&lt;br /&gt;
|-&lt;br /&gt;
| &amp;lt;math&amp;gt;E&amp;lt;/math&amp;gt; || Energy released by the specimen over the interval || kJ&lt;br /&gt;
|-&lt;br /&gt;
| &amp;lt;math&amp;gt;t&amp;lt;/math&amp;gt; || Length of the interval || s&lt;br /&gt;
|-&lt;br /&gt;
| &amp;lt;math&amp;gt;\overline{\dot Q}&amp;lt;/math&amp;gt; || Mean heat release rate over that interval || kW&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
Two products can release the same total energy and reach quite different peaks. The arithmetic alone cannot determine FIGRA, the smoke classification or the overall class.&amp;lt;ref name=&amp;quot;sbiclass&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;sbi&amp;quot; /&amp;gt;&lt;br /&gt;
[[File:fse-single-burning-item-test-v3.svg|thumb|upright=1.5|alt=A rectangle 600 seconds wide and 12.5 kilowatts high represents 7.5 megajoules of energy.|A mean of 12.5 kW over 600 s corresponds to 7.5 MJ. The rectangle represents the equivalent average. Based on Hirschler (2008), §6.3, Table 6.3.6, p. 6-52.]]&lt;br /&gt;
&lt;br /&gt;
== Where the test has limits ==&lt;br /&gt;
A [[Cone calorimeter|cone calorimeter]] exposes a small specimen to radiant heat. The SBI uses a corner without a ceiling, while the [[Room corner test|room corner test]] exposes linings in an enclosure. For some metal-faced sandwich panels, the SBI exposure did not reach the combustible core in the same way as the room test. This is one reason to identify the scale and exposure when comparing [[Fire testing|fire testing]] reports.&amp;lt;ref name=&amp;quot;sbisand&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;sbiro&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== See also ==&lt;br /&gt;
* [[Flame spread]]&lt;br /&gt;
* [[Large-scale facade fire test]]&lt;br /&gt;
* [[Fire resistance test]]&lt;br /&gt;
&lt;br /&gt;
== Notes ==&lt;br /&gt;
&amp;lt;references /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== References ==&lt;br /&gt;
* Babrauskas, V. (2002). Heat release rates. In P. J. DiNenno (Ed.), &amp;#039;&amp;#039;SFPE handbook of fire protection engineering&amp;#039;&amp;#039; (3rd ed.). National Fire Protection Association.&lt;br /&gt;
* Hirschler, M. M. (2008). Concepts and protocols of fire testing. In A. E. Cote (Ed.), &amp;#039;&amp;#039;Fire protection handbook&amp;#039;&amp;#039; (20th ed.). National Fire Protection Association.&lt;br /&gt;
* Madrzykowski, D., &amp;amp; Stroup, D. W. (2008). Flammability hazard of materials. In A. E. Cote (Ed.), &amp;#039;&amp;#039;Fire protection handbook&amp;#039;&amp;#039; (20th ed.). National Fire Protection Association.&lt;br /&gt;
&lt;br /&gt;
[[Category:Materials &amp;amp; Fire Testing]]&lt;/div&gt;</summary>