<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://fire-safety.academy/w/index.php?action=history&amp;feed=atom&amp;title=Rate-of-rise_heat_detector</id>
	<title>Rate-of-rise heat detector - Revision history</title>
	<link rel="self" type="application/atom+xml" href="https://fire-safety.academy/w/index.php?action=history&amp;feed=atom&amp;title=Rate-of-rise_heat_detector"/>
	<link rel="alternate" type="text/html" href="https://fire-safety.academy/w/index.php?title=Rate-of-rise_heat_detector&amp;action=history"/>
	<updated>2026-11-22T00:09:10Z</updated>
	<subtitle>Revision history for this page on the wiki</subtitle>
	<generator>MediaWiki 1.43.11</generator>
	<entry>
		<id>https://fire-safety.academy/w/index.php?title=Rate-of-rise_heat_detector&amp;diff=9171&amp;oldid=prev</id>
		<title>Peter: Wiki review: corrected 11 errors: citation (8), markup (3) (Claude Opus 5.5)</title>
		<link rel="alternate" type="text/html" href="https://fire-safety.academy/w/index.php?title=Rate-of-rise_heat_detector&amp;diff=9171&amp;oldid=prev"/>
		<updated>2026-11-15T23:34:05Z</updated>

		<summary type="html">&lt;p&gt;Wiki review: corrected 11 errors: citation (8), markup (3) (Claude Opus 5.5)&lt;/p&gt;
&lt;table style=&quot;background-color: #fff; color: #202122;&quot; data-mw=&quot;interface&quot;&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;tr class=&quot;diff-title&quot; lang=&quot;en&quot;&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;← Older revision&lt;/td&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;Revision as of 00:34, 16 November 2026&lt;/td&gt;
				&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l1&quot;&gt;Line 1:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 1:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;A &amp;#039;&amp;#039;&amp;#039;rate-of-rise [[Heat detector|heat detector]]&amp;#039;&amp;#039;&amp;#039; responds when temperature increases faster than a specified rate. It measures a change over time rather than only whether a fixed temperature has been reached. The Fire Protection Handbook describes pneumatic and electronic forms, including devices that combine rate-of-rise and fixed-temperature operation.&amp;lt;ref name=&amp;quot;F-6f102e82c9&amp;quot;&amp;gt;Cote et al. (2008), chapter 14.2, pp. 14-17–14-19.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;A &amp;#039;&amp;#039;&amp;#039;rate-of-rise [[Heat detector|heat detector]]&amp;#039;&amp;#039;&amp;#039; responds when temperature increases faster than a specified rate. It measures a change over time rather than only whether a fixed temperature has been reached. The Fire Protection Handbook describes pneumatic and electronic forms, including devices that combine rate-of-rise and fixed-temperature operation.&amp;lt;ref name=&amp;quot;F-6f102e82c9&amp;quot;&amp;gt;Cote et al. (2008), chapter 14.2, pp. 14-17–14-19.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[[File:fse-rate-of-rise-heat-detector-v1.svg|thumb|upright=1.5|alt=&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;Separate &lt;/del&gt;temperature change rate &lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;from &lt;/del&gt;a fixed &lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;threshold&lt;/del&gt;.|&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;Separate &lt;/del&gt;temperature &lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;change &lt;/del&gt;rate &lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;from a fixed threshold&lt;/del&gt;.]]&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[[File:fse-rate-of-rise-heat-detector-v1.svg|thumb|upright=1.5|alt=&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;A &lt;/ins&gt;temperature change &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;feeds two branches, a &lt;/ins&gt;rate &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;response (rate of change dT/dt) and &lt;/ins&gt;a fixed&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;-temperature response (temperature T), both leading to an alarm input&lt;/ins&gt;.|&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;Rate response and fixed-&lt;/ins&gt;temperature &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;response use different criteria; rate-of-rise operation is not the same as &lt;/ins&gt;rate &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;compensation&lt;/ins&gt;.]]&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The detector is a type of heat detector and can act as an [[Initiating device|initiating device]] in an alarm installation. Its response depends on the heating history produced by the fire and the surrounding airflow. A [[Ceiling jet|ceiling jet]] can deliver that heat, while [[Detector spacing|detector spacing]] influences the location at which the device experiences it.&amp;lt;ref name=&amp;quot;F-bb5da34c80&amp;quot;&amp;gt;Cote et al. (2008), chapter 14.2, pp. 14-16–14-19, 14-27.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The detector is a type of heat detector and can act as an [[Initiating device|initiating device]] in an alarm installation. Its response depends on the heating history produced by the fire and the surrounding airflow. A [[Ceiling jet|ceiling jet]] can deliver that heat, while [[Detector spacing|detector spacing]] influences the location at which the device experiences it.&amp;lt;ref name=&amp;quot;F-bb5da34c80&amp;quot;&amp;gt;Cote et al. (2008), chapter 14.2, pp. 14-16–14-19, 14-27.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l9&quot;&gt;Line 9:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 9:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;A pneumatic device contains air that expands when heated. A restricted vent allows slow changes to equalise with the surroundings. When heating is sufficiently rapid, expansion exceeds the venting rate and pressure moves a diaphragm that operates contacts. The mechanism therefore compares heating with pressure equalisation rather than directly measuring a flame.&amp;lt;ref name=&amp;quot;F-4d4078b9f3&amp;quot;&amp;gt;Cote et al. (2008), chapter 14.2, pp. 14-17–14-18.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;A pneumatic device contains air that expands when heated. A restricted vent allows slow changes to equalise with the surroundings. When heating is sufficiently rapid, expansion exceeds the venting rate and pressure moves a diaphragm that operates contacts. The mechanism therefore compares heating with pressure equalisation rather than directly measuring a flame.&amp;lt;ref name=&amp;quot;F-4d4078b9f3&amp;quot;&amp;gt;Cote et al. (2008), chapter 14.2, pp. 14-17–14-18.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;An electronic arrangement can compare thermistors that respond differently to changes in ambient temperature. The exposed sensing element responds more rapidly than the reference element. Processing interprets the difference as a rate-related condition. The handbook describes fixed-temperature backup as a means of retaining response to slower heating that does not reach the rate threshold.&amp;lt;ref name=&quot;F-d75465fddb&quot;&amp;gt;Cote et al. (2008), chapter 14.2, &lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;pp&lt;/del&gt;. 14-19.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;An electronic arrangement can compare thermistors that respond differently to changes in ambient temperature. The exposed sensing element responds more rapidly than the reference element. Processing interprets the difference as a rate-related condition. The handbook describes fixed-temperature backup as a means of retaining response to slower heating that does not reach the rate threshold.&amp;lt;ref name=&quot;F-d75465fddb&quot;&amp;gt;Cote et al. (2008), chapter 14.2, &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;p&lt;/ins&gt;. 14-19.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;A rate-compensation device has another objective. Its construction compensates for thermal lag so that operation corresponds more closely to a specified surrounding temperature. It is consequently not a synonym for rate-of-rise detection. The two mechanisms consequently require separate interpretation when selecting a detector.&amp;lt;ref name=&quot;F-7a0dfd6628&quot;&amp;gt;Cote et al. (2008), chapter 14.2, &lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;pp&lt;/del&gt;. 14-17.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;A rate-compensation device has another objective. Its construction compensates for thermal lag so that operation corresponds more closely to a specified surrounding temperature. It is consequently not a synonym for rate-of-rise detection. The two mechanisms consequently require separate interpretation when selecting a detector.&amp;lt;ref name=&quot;F-7a0dfd6628&quot;&amp;gt;Cote et al. (2008), chapter 14.2, &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;p&lt;/ins&gt;. 14-17.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Rapid non-fire temperature changes can also produce the relevant stimulus. The handbook identifies heating equipment, kitchens and other variable-temperature environments as application concerns. Selection therefore considers both expected fire heating and ordinary operation of the space. A rate-sensitive function cannot independently determine why the temperature changed.&amp;lt;ref name=&amp;quot;F-6f102e82c9&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Rapid non-fire temperature changes can also produce the relevant stimulus. The handbook identifies heating equipment, kitchens and other variable-temperature environments as application concerns. Selection therefore considers both expected fire heating and ordinary operation of the space. A rate-sensitive function cannot independently determine why the temperature changed.&amp;lt;ref name=&amp;quot;F-6f102e82c9&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Fire signatures and detector selection ==&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Fire signatures and detector selection ==&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;A fire signature is a measurable effect associated with combustion. Heat, suspended smoke particles and radiant energy provide different signatures, and detector technologies respond to different parts of that information. A detector can therefore be highly sensitive to one type of fire and comparatively slow for another. Selection begins with the fires and environmental conditions expected in the protected space.&amp;lt;ref name=&quot;S-fd76472e02&quot;&amp;gt;Schifiliti et al. (2002), &lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;pp&lt;/del&gt;. 4-3.&amp;lt;/ref&amp;gt;&amp;lt;ref name=&quot;F-e5e5ba2507&quot;&amp;gt;Cote et al. (2008), chapter 14.2, &lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;pp&lt;/del&gt;. 14-15.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;A fire signature is a measurable effect associated with combustion. Heat, suspended smoke particles and radiant energy provide different signatures, and detector technologies respond to different parts of that information. A detector can therefore be highly sensitive to one type of fire and comparatively slow for another. Selection begins with the fires and environmental conditions expected in the protected space.&amp;lt;ref name=&quot;S-fd76472e02&quot;&amp;gt;Schifiliti et al. (2002), &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;p&lt;/ins&gt;. 4-3.&amp;lt;/ref&amp;gt;&amp;lt;ref name=&quot;F-e5e5ba2507&quot;&amp;gt;Cote et al. (2008), chapter 14.2, &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;p&lt;/ins&gt;. 14-15.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[[File:fse-rate-of-rise-heat-detector-v2.svg|thumb|upright=1.5|alt=&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;Explain &lt;/del&gt;the &lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;mechanism supporting rate-of-rise heat detector&lt;/del&gt;.|&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;Explain &lt;/del&gt;the &lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;mechanism supporting rate-&lt;/del&gt;of&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;-rise heat detector&lt;/del&gt;.]]&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[[File:fse-rate-of-rise-heat-detector-v2.svg|thumb|upright=1.5|alt=&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;Heat, smoke particles and radiant energy as fire signatures feeding sensor selection, with environmental interference also influencing &lt;/ins&gt;the &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;choice&lt;/ins&gt;.|&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;Detector selection depends on &lt;/ins&gt;the &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;expected fire signatures and on the environment, including sources &lt;/ins&gt;of &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;interference&lt;/ins&gt;.]]&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Flaming and smouldering fires illustrate this distinction. A rapidly flaming fire can produce substantial heat and a strong radiation signal. A smouldering fire can produce smoke without a visible flame and with relatively little heat. A detection strategy based only on heat or visible flame may consequently respond differently from one based on smoke. The relevant comparison is response to the selected scenario, rather than an abstract ranking of all detectors.&amp;lt;ref name=&amp;quot;F-b20170c94c&amp;quot;&amp;gt;Cote et al. (2008), chapter 14.2, pp. 14-15–14-19.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Flaming and smouldering fires illustrate this distinction. A rapidly flaming fire can produce substantial heat and a strong radiation signal. A smouldering fire can produce smoke without a visible flame and with relatively little heat. A detection strategy based only on heat or visible flame may consequently respond differently from one based on smoke. The relevant comparison is response to the selected scenario, rather than an abstract ranking of all detectors.&amp;lt;ref name=&amp;quot;F-b20170c94c&amp;quot;&amp;gt;Cote et al. (2008), chapter 14.2, pp. 14-15–14-19.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l23&quot;&gt;Line 23:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 23:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Non-fire processes can resemble the signature that a detector is intended to recognise. Airborne dust, process aerosols and normal temperature changes can therefore influence selection and location. Increasing sensitivity can shorten response to a fire while increasing response to unwanted stimuli. The handbook describes selection as a balance between useful sensitivity and discrimination under the expected environmental conditions.&amp;lt;ref name=&amp;quot;F-5dba1efe59&amp;quot;&amp;gt;Cote et al. (2008), chapter 14.2, pp. 14-15, 14-26.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Non-fire processes can resemble the signature that a detector is intended to recognise. Airborne dust, process aerosols and normal temperature changes can therefore influence selection and location. Increasing sensitivity can shorten response to a fire while increasing response to unwanted stimuli. The handbook describes selection as a balance between useful sensitivity and discrimination under the expected environmental conditions.&amp;lt;ref name=&amp;quot;F-5dba1efe59&amp;quot;&amp;gt;Cote et al. (2008), chapter 14.2, pp. 14-15, 14-26.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;A combined detector does not necessarily treat every sensor in the same way. Some combinations contain independently operating sensing elements. Multicriteria equipment instead combines information through a processing algorithm before deciding whether to signal. The resulting response belongs to that particular sensing and processing arrangement. The presence of several sensors does not establish a universal response time or remove the need to examine nuisance conditions.&amp;lt;ref name=&quot;F-5ea64bae68&quot;&amp;gt;Cote et al. (2008), chapter 14.2, &lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;pp&lt;/del&gt;. 14-23.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;A combined detector does not necessarily treat every sensor in the same way. Some combinations contain independently operating sensing elements. Multicriteria equipment instead combines information through a processing algorithm before deciding whether to signal. The resulting response belongs to that particular sensing and processing arrangement. The presence of several sensors does not establish a universal response time or remove the need to examine nuisance conditions.&amp;lt;ref name=&quot;F-5ea64bae68&quot;&amp;gt;Cote et al. (2008), chapter 14.2, &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;p&lt;/ins&gt;. 14-23.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Smoke sensing and signal interpretation ==&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Smoke sensing and signal interpretation ==&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l41&quot;&gt;Line 41:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 41:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Different detection methods impose different transport conditions. An aspirating system draws sampled air through pipework, introducing transport time and possible dilution between sampling ports. A projected beam measures smoke along an optical path rather than at a single point. Video detection analyses an image and therefore does not require smoke to enter a local sensing chamber. Each arrangement introduces its own limitations concerning coverage, obstruction and interpretation.&amp;lt;ref name=&amp;quot;F-724337824e&amp;quot;&amp;gt;Cote et al. (2008), chapter 14.2, pp. 14-21–14-23.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Different detection methods impose different transport conditions. An aspirating system draws sampled air through pipework, introducing transport time and possible dilution between sampling ports. A projected beam measures smoke along an optical path rather than at a single point. Video detection analyses an image and therefore does not require smoke to enter a local sensing chamber. Each arrangement introduces its own limitations concerning coverage, obstruction and interpretation.&amp;lt;ref name=&amp;quot;F-724337824e&amp;quot;&amp;gt;Cote et al. (2008), chapter 14.2, pp. 14-21–14-23.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Duct detection has a different purpose from open-area detection. Smoke in a duct may be diluted by air returning from other rooms, and it may not reach the detector when the fan is stopped. The handbook consequently distinguishes control of smoke circulation from protection of an occupied space itself. Coverage is assessed against the function being claimed, including the relevant operating and non-operating states of the ventilation system.&amp;lt;ref name=&quot;F-97c29afec9&quot;&amp;gt;Cote et al. (2008), chapter 14.2, &lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;pp&lt;/del&gt;. 14-27.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Duct detection has a different purpose from open-area detection. Smoke in a duct may be diluted by air returning from other rooms, and it may not reach the detector when the fan is stopped. The handbook consequently distinguishes control of smoke circulation from protection of an occupied space itself. Coverage is assessed against the function being claimed, including the relevant operating and non-operating states of the ventilation system.&amp;lt;ref name=&quot;F-97c29afec9&quot;&amp;gt;Cote et al. (2008), chapter 14.2, &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;p&lt;/ins&gt;. 14-27.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Heat response and the meaning of spacing ==&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Heat response and the meaning of spacing ==&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l50&quot;&gt;Line 50:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 50:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The handbook distinguishes the test basis of heat-detector spacing from the conventional nominal spacing used for smoke detectors. Listed heat-detector spacing relates to a defined fire-test arrangement and response comparison. It does not mean that a fire of any size will be detected within a fixed time anywhere in the resulting area. Ceiling height, ambient conditions, fire growth and the detector&amp;#039;s thermal response still influence the result.&amp;lt;ref name=&amp;quot;S-21ffe36703&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;F-97c29afec9&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The handbook distinguishes the test basis of heat-detector spacing from the conventional nominal spacing used for smoke detectors. Listed heat-detector spacing relates to a defined fire-test arrangement and response comparison. It does not mean that a fire of any size will be detected within a fixed time anywhere in the resulting area. Ceiling height, ambient conditions, fire growth and the detector&amp;#039;s thermal response still influence the result.&amp;lt;ref name=&amp;quot;S-21ffe36703&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;F-97c29afec9&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Performance assessment therefore combines the fire environment with the sensing element&#039;s response. A model can estimate gas temperature and velocity near a detector and then estimate heating of the element. The assumptions must match the type of fire and enclosure being represented. The handbook cautions that a plume-based approach developed for flaming fires cannot simply be transferred to low-energy smouldering scenarios.&amp;lt;ref name=&quot;F-97c29afec9&quot; /&amp;gt;&amp;lt;ref name=&quot;S-6654fefff7&quot;&amp;gt;Schifiliti et al. (2002), &lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;pp&lt;/del&gt;. 4-4.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Performance assessment therefore combines the fire environment with the sensing element&#039;s response. A model can estimate gas temperature and velocity near a detector and then estimate heating of the element. The assumptions must match the type of fire and enclosure being represented. The handbook cautions that a plume-based approach developed for flaming fires cannot simply be transferred to low-energy smouldering scenarios.&amp;lt;ref name=&quot;F-97c29afec9&quot; /&amp;gt;&amp;lt;ref name=&quot;S-6654fefff7&quot;&amp;gt;Schifiliti et al. (2002), &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;p&lt;/ins&gt;. 4-4.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Protection objectives and response time ==&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Protection objectives and response time ==&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l63&quot;&gt;Line 63:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 63:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Inspection, testing and continuing performance ==&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Inspection, testing and continuing performance ==&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Inspection, testing and maintenance answer different questions about the installation. Inspection can reveal damage, obstruction, unsuitable surroundings or changes in the protected space. Functional testing demonstrates an intended response under a stated test condition. Maintenance addresses defects and deterioration so that the installation can continue to perform its specified functions. The handbook treats these activities as part of the original protection design.&amp;lt;ref name=&amp;quot;F-c183541efa&amp;quot;&amp;gt;Cote et al. (2008), chapter 14.5, pp. 14-53–14-54, 14-61–14-62.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Inspection, testing and maintenance answer different questions about the installation. Inspection can reveal damage, obstruction, unsuitable surroundings or changes in the protected space. Functional testing demonstrates an intended response under a stated test condition. Maintenance addresses defects and deterioration so that the installation can continue to perform its specified functions. The handbook treats these activities as part of the original protection design.&amp;lt;ref name=&amp;quot;F-c183541efa&amp;quot;&amp;gt;Cote et al. (2008), chapter 14.5, pp. 14-53–14-54, 14-61–14-62.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[[File:fse-rate-of-rise-heat-detector-v3.svg|thumb|upright=1.5|alt=&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;Distinguish complementary evidence needed to assess rate-of-rise heat detector&lt;/del&gt;.|&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;Distinguish complementary &lt;/del&gt;evidence &lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;needed to assess &lt;/del&gt;rate-of-rise heat detector.]]&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[[File:fse-rate-of-rise-heat-detector-v3.svg|thumb|upright=1.5|alt=&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;Physical inspection, functional test, integrated response and recorded conditions, each with what it establishes and does not prove, combined into an assessment that is reviewed after changed conditions&lt;/ins&gt;.|&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;Complementary &lt;/ins&gt;evidence &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;for assessing a &lt;/ins&gt;rate-of-rise heat detector&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;, and what each kind of evidence does not prove&lt;/ins&gt;.]]&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Acceptance testing checks the installed arrangement against its intended sequence of operation. Changes to hardware, wiring or software can require reacceptance testing because they can affect previously demonstrated functions. The scope of the assessment depends on the change and its consequences. Records make the original arrangement, subsequent changes and observed performance available for later comparison.&amp;lt;ref name=&amp;quot;F-d70f9bf924&amp;quot;&amp;gt;Cote et al. (2008), chapter 14.5, pp. 14-61–14-62.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Acceptance testing checks the installed arrangement against its intended sequence of operation. Changes to hardware, wiring or software can require reacceptance testing because they can affect previously demonstrated functions. The scope of the assessment depends on the change and its consequences. Records make the original arrangement, subsequent changes and observed performance available for later comparison.&amp;lt;ref name=&amp;quot;F-d70f9bf924&amp;quot;&amp;gt;Cote et al. (2008), chapter 14.5, pp. 14-61–14-62.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Electrical supervision cannot identify every physical impairment. A communicating smoke detector may have an obstructed smoke-entry path, and an interface may remain electrically normal while its mechanical connection is ineffective. The handbook specifically identifies painting, covering and changed airflows as reasons for examining detectors physically. Test planning therefore includes the real stimulus and the downstream response wherever those are necessary to demonstrate the required function.&amp;lt;ref name=&quot;F-527d72e812&quot;&amp;gt;Cote et al. (2008), chapter 14.2, &lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;pp&lt;/del&gt;. 14-28.&amp;lt;/ref&amp;gt;&amp;lt;ref name=&quot;F-d70f9bf924&quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Electrical supervision cannot identify every physical impairment. A communicating smoke detector may have an obstructed smoke-entry path, and an interface may remain electrically normal while its mechanical connection is ineffective. The handbook specifically identifies painting, covering and changed airflows as reasons for examining detectors physically. Test planning therefore includes the real stimulus and the downstream response wherever those are necessary to demonstrate the required function.&amp;lt;ref name=&quot;F-527d72e812&quot;&amp;gt;Cote et al. (2008), chapter 14.2, &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;p&lt;/ins&gt;. 14-28.&amp;lt;/ref&amp;gt;&amp;lt;ref name=&quot;F-d70f9bf924&quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The Australian part of the International Fire Engineering Guidelines, published in 2005, connects commissioning with management and maintenance throughout building use. It also identifies alterations as a possible challenge to the original engineering assumptions. A changed layout or operating procedure can invalidate an earlier assessment without causing an electrical fault. Continuing performance consequently involves reviewing both equipment condition and the circumstances in which the equipment is expected to work.&amp;lt;ref name=&amp;quot;I-abe1241982&amp;quot;&amp;gt;National Research Council of Canada et al. (2005), §0.3.2.4–0.3.2.8; pp. 0.3-6–0.3-7.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The Australian part of the International Fire Engineering Guidelines, published in 2005, connects commissioning with management and maintenance throughout building use. It also identifies alterations as a possible challenge to the original engineering assumptions. A changed layout or operating procedure can invalidate an earlier assessment without causing an electrical fault. Continuing performance consequently involves reviewing both equipment condition and the circumstances in which the equipment is expected to work.&amp;lt;ref name=&amp;quot;I-abe1241982&amp;quot;&amp;gt;National Research Council of Canada et al. (2005), §0.3.2.4–0.3.2.8; pp. 0.3-6–0.3-7.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;

&lt;!-- diff cache key firesb_pjbsiy42-wiki_:diff:1.41:old-6760:rev-9171:php=table --&gt;
&lt;/table&gt;</summary>
		<author><name>Peter</name></author>
	</entry>
	<entry>
		<id>https://fire-safety.academy/w/index.php?title=Rate-of-rise_heat_detector&amp;diff=6760&amp;oldid=prev</id>
		<title>Mark: Remove source references from image captions</title>
		<link rel="alternate" type="text/html" href="https://fire-safety.academy/w/index.php?title=Rate-of-rise_heat_detector&amp;diff=6760&amp;oldid=prev"/>
		<updated>2026-11-13T07:34:24Z</updated>

		<summary type="html">&lt;p&gt;Remove source references from image captions&lt;/p&gt;
&lt;table style=&quot;background-color: #fff; color: #202122;&quot; data-mw=&quot;interface&quot;&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;tr class=&quot;diff-title&quot; lang=&quot;en&quot;&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;← Older revision&lt;/td&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;Revision as of 08:34, 13 November 2026&lt;/td&gt;
				&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l1&quot;&gt;Line 1:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 1:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;A &amp;#039;&amp;#039;&amp;#039;rate-of-rise [[Heat detector|heat detector]]&amp;#039;&amp;#039;&amp;#039; responds when temperature increases faster than a specified rate. It measures a change over time rather than only whether a fixed temperature has been reached. The Fire Protection Handbook describes pneumatic and electronic forms, including devices that combine rate-of-rise and fixed-temperature operation.&amp;lt;ref name=&amp;quot;F-6f102e82c9&amp;quot;&amp;gt;Cote et al. (2008), chapter 14.2, pp. 14-17–14-19.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;A &amp;#039;&amp;#039;&amp;#039;rate-of-rise [[Heat detector|heat detector]]&amp;#039;&amp;#039;&amp;#039; responds when temperature increases faster than a specified rate. It measures a change over time rather than only whether a fixed temperature has been reached. The Fire Protection Handbook describes pneumatic and electronic forms, including devices that combine rate-of-rise and fixed-temperature operation.&amp;lt;ref name=&amp;quot;F-6f102e82c9&amp;quot;&amp;gt;Cote et al. (2008), chapter 14.2, pp. 14-17–14-19.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[[File:fse-rate-of-rise-heat-detector-v1.svg|thumb|upright=1.5|alt=Separate temperature change rate from a fixed threshold.|Separate temperature change rate from a fixed threshold&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;. Based on Cote et al. (2008), chapter 14.2, pp. 14-17–14-19; Cote et al. (2008), chapter 14.2, pp. 14-16–14-19, 14-27; Cote et al. (2008), chapter 14.2, pp. 14-17–14-19, 14-27&lt;/del&gt;.]]&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[[File:fse-rate-of-rise-heat-detector-v1.svg|thumb|upright=1.5|alt=Separate temperature change rate from a fixed threshold.|Separate temperature change rate from a fixed threshold.]]&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The detector is a type of heat detector and can act as an [[Initiating device|initiating device]] in an alarm installation. Its response depends on the heating history produced by the fire and the surrounding airflow. A [[Ceiling jet|ceiling jet]] can deliver that heat, while [[Detector spacing|detector spacing]] influences the location at which the device experiences it.&amp;lt;ref name=&amp;quot;F-bb5da34c80&amp;quot;&amp;gt;Cote et al. (2008), chapter 14.2, pp. 14-16–14-19, 14-27.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The detector is a type of heat detector and can act as an [[Initiating device|initiating device]] in an alarm installation. Its response depends on the heating history produced by the fire and the surrounding airflow. A [[Ceiling jet|ceiling jet]] can deliver that heat, while [[Detector spacing|detector spacing]] influences the location at which the device experiences it.&amp;lt;ref name=&amp;quot;F-bb5da34c80&amp;quot;&amp;gt;Cote et al. (2008), chapter 14.2, pp. 14-16–14-19, 14-27.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l17&quot;&gt;Line 17:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 17:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Fire signatures and detector selection ==&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Fire signatures and detector selection ==&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;A fire signature is a measurable effect associated with combustion. Heat, suspended smoke particles and radiant energy provide different signatures, and detector technologies respond to different parts of that information. A detector can therefore be highly sensitive to one type of fire and comparatively slow for another. Selection begins with the fires and environmental conditions expected in the protected space.&amp;lt;ref name=&amp;quot;S-fd76472e02&amp;quot;&amp;gt;Schifiliti et al. (2002), pp. 4-3.&amp;lt;/ref&amp;gt;&amp;lt;ref name=&amp;quot;F-e5e5ba2507&amp;quot;&amp;gt;Cote et al. (2008), chapter 14.2, pp. 14-15.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;A fire signature is a measurable effect associated with combustion. Heat, suspended smoke particles and radiant energy provide different signatures, and detector technologies respond to different parts of that information. A detector can therefore be highly sensitive to one type of fire and comparatively slow for another. Selection begins with the fires and environmental conditions expected in the protected space.&amp;lt;ref name=&amp;quot;S-fd76472e02&amp;quot;&amp;gt;Schifiliti et al. (2002), pp. 4-3.&amp;lt;/ref&amp;gt;&amp;lt;ref name=&amp;quot;F-e5e5ba2507&amp;quot;&amp;gt;Cote et al. (2008), chapter 14.2, pp. 14-15.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[[File:fse-rate-of-rise-heat-detector-v2.svg|thumb|upright=1.5|alt=Explain the mechanism supporting rate-of-rise heat detector.|Explain the mechanism supporting rate-of-rise heat detector&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;. Based on Schifiliti et al. (2002), pp. 4-3; Cote et al. (2008), chapter 14.2, pp. 14-15; Cote et al. (2008), chapter 14.2, pp. 14-15–14-19&lt;/del&gt;.]]&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[[File:fse-rate-of-rise-heat-detector-v2.svg|thumb|upright=1.5|alt=Explain the mechanism supporting rate-of-rise heat detector.|Explain the mechanism supporting rate-of-rise heat detector.]]&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Flaming and smouldering fires illustrate this distinction. A rapidly flaming fire can produce substantial heat and a strong radiation signal. A smouldering fire can produce smoke without a visible flame and with relatively little heat. A detection strategy based only on heat or visible flame may consequently respond differently from one based on smoke. The relevant comparison is response to the selected scenario, rather than an abstract ranking of all detectors.&amp;lt;ref name=&amp;quot;F-b20170c94c&amp;quot;&amp;gt;Cote et al. (2008), chapter 14.2, pp. 14-15–14-19.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Flaming and smouldering fires illustrate this distinction. A rapidly flaming fire can produce substantial heat and a strong radiation signal. A smouldering fire can produce smoke without a visible flame and with relatively little heat. A detection strategy based only on heat or visible flame may consequently respond differently from one based on smoke. The relevant comparison is response to the selected scenario, rather than an abstract ranking of all detectors.&amp;lt;ref name=&amp;quot;F-b20170c94c&amp;quot;&amp;gt;Cote et al. (2008), chapter 14.2, pp. 14-15–14-19.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l63&quot;&gt;Line 63:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 63:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Inspection, testing and continuing performance ==&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Inspection, testing and continuing performance ==&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Inspection, testing and maintenance answer different questions about the installation. Inspection can reveal damage, obstruction, unsuitable surroundings or changes in the protected space. Functional testing demonstrates an intended response under a stated test condition. Maintenance addresses defects and deterioration so that the installation can continue to perform its specified functions. The handbook treats these activities as part of the original protection design.&amp;lt;ref name=&amp;quot;F-c183541efa&amp;quot;&amp;gt;Cote et al. (2008), chapter 14.5, pp. 14-53–14-54, 14-61–14-62.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Inspection, testing and maintenance answer different questions about the installation. Inspection can reveal damage, obstruction, unsuitable surroundings or changes in the protected space. Functional testing demonstrates an intended response under a stated test condition. Maintenance addresses defects and deterioration so that the installation can continue to perform its specified functions. The handbook treats these activities as part of the original protection design.&amp;lt;ref name=&amp;quot;F-c183541efa&amp;quot;&amp;gt;Cote et al. (2008), chapter 14.5, pp. 14-53–14-54, 14-61–14-62.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[[File:fse-rate-of-rise-heat-detector-v3.svg|thumb|upright=1.5|alt=Distinguish complementary evidence needed to assess rate-of-rise heat detector.|Distinguish complementary evidence needed to assess rate-of-rise heat detector&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;. Based on Cote et al. (2008), chapter 14.5, pp. 14-53–14-54, 14-61–14-62; Cote et al. (2008), chapter 14.5, pp. 14-61–14-62; Cote et al. (2008), chapter 14.2, pp. 14-28&lt;/del&gt;.]]&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[[File:fse-rate-of-rise-heat-detector-v3.svg|thumb|upright=1.5|alt=Distinguish complementary evidence needed to assess rate-of-rise heat detector.|Distinguish complementary evidence needed to assess rate-of-rise heat detector.]]&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Acceptance testing checks the installed arrangement against its intended sequence of operation. Changes to hardware, wiring or software can require reacceptance testing because they can affect previously demonstrated functions. The scope of the assessment depends on the change and its consequences. Records make the original arrangement, subsequent changes and observed performance available for later comparison.&amp;lt;ref name=&amp;quot;F-d70f9bf924&amp;quot;&amp;gt;Cote et al. (2008), chapter 14.5, pp. 14-61–14-62.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Acceptance testing checks the installed arrangement against its intended sequence of operation. Changes to hardware, wiring or software can require reacceptance testing because they can affect previously demonstrated functions. The scope of the assessment depends on the change and its consequences. Records make the original arrangement, subsequent changes and observed performance available for later comparison.&amp;lt;ref name=&amp;quot;F-d70f9bf924&amp;quot;&amp;gt;Cote et al. (2008), chapter 14.5, pp. 14-61–14-62.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;

&lt;!-- diff cache key firesb_pjbsiy42-wiki_:diff:1.41:old-6124:rev-6760:php=table --&gt;
&lt;/table&gt;</summary>
		<author><name>Mark</name></author>
	</entry>
	<entry>
		<id>https://fire-safety.academy/w/index.php?title=Rate-of-rise_heat_detector&amp;diff=6124&amp;oldid=prev</id>
		<title>Peter: Add SVG figures fse-rate-of-rise-heat-detector-v1.svg, fse-rate-of-rise-heat-detector-v2.svg, fse-rate-of-rise-heat-detector-v3.svg (list-4 visual plan)</title>
		<link rel="alternate" type="text/html" href="https://fire-safety.academy/w/index.php?title=Rate-of-rise_heat_detector&amp;diff=6124&amp;oldid=prev"/>
		<updated>2026-11-12T15:07:13Z</updated>

		<summary type="html">&lt;p&gt;Add SVG figures fse-rate-of-rise-heat-detector-v1.svg, fse-rate-of-rise-heat-detector-v2.svg, fse-rate-of-rise-heat-detector-v3.svg (list-4 visual plan)&lt;/p&gt;
&lt;table style=&quot;background-color: #fff; color: #202122;&quot; data-mw=&quot;interface&quot;&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;tr class=&quot;diff-title&quot; lang=&quot;en&quot;&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;← Older revision&lt;/td&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;Revision as of 16:07, 12 November 2026&lt;/td&gt;
				&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l1&quot;&gt;Line 1:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 1:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;A &amp;#039;&amp;#039;&amp;#039;rate-of-rise [[Heat detector|heat detector]]&amp;#039;&amp;#039;&amp;#039; responds when temperature increases faster than a specified rate. It measures a change over time rather than only whether a fixed temperature has been reached. The Fire Protection Handbook describes pneumatic and electronic forms, including devices that combine rate-of-rise and fixed-temperature operation.&amp;lt;ref name=&amp;quot;F-6f102e82c9&amp;quot;&amp;gt;Cote et al. (2008), chapter 14.2, pp. 14-17–14-19.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;A &amp;#039;&amp;#039;&amp;#039;rate-of-rise [[Heat detector|heat detector]]&amp;#039;&amp;#039;&amp;#039; responds when temperature increases faster than a specified rate. It measures a change over time rather than only whether a fixed temperature has been reached. The Fire Protection Handbook describes pneumatic and electronic forms, including devices that combine rate-of-rise and fixed-temperature operation.&amp;lt;ref name=&amp;quot;F-6f102e82c9&amp;quot;&amp;gt;Cote et al. (2008), chapter 14.2, pp. 14-17–14-19.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-deleted&quot;&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;[[File:fse-rate-of-rise-heat-detector-v1.svg|thumb|upright=1.5|alt=Separate temperature change rate from a fixed threshold.|Separate temperature change rate from a fixed threshold. Based on Cote et al. (2008), chapter 14.2, pp. 14-17–14-19; Cote et al. (2008), chapter 14.2, pp. 14-16–14-19, 14-27; Cote et al. (2008), chapter 14.2, pp. 14-17–14-19, 14-27.]]&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The detector is a type of heat detector and can act as an [[Initiating device|initiating device]] in an alarm installation. Its response depends on the heating history produced by the fire and the surrounding airflow. A [[Ceiling jet|ceiling jet]] can deliver that heat, while [[Detector spacing|detector spacing]] influences the location at which the device experiences it.&amp;lt;ref name=&amp;quot;F-bb5da34c80&amp;quot;&amp;gt;Cote et al. (2008), chapter 14.2, pp. 14-16–14-19, 14-27.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The detector is a type of heat detector and can act as an [[Initiating device|initiating device]] in an alarm installation. Its response depends on the heating history produced by the fire and the surrounding airflow. A [[Ceiling jet|ceiling jet]] can deliver that heat, while [[Detector spacing|detector spacing]] influences the location at which the device experiences it.&amp;lt;ref name=&amp;quot;F-bb5da34c80&amp;quot;&amp;gt;Cote et al. (2008), chapter 14.2, pp. 14-16–14-19, 14-27.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l16&quot;&gt;Line 16:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 17:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Fire signatures and detector selection ==&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Fire signatures and detector selection ==&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;A fire signature is a measurable effect associated with combustion. Heat, suspended smoke particles and radiant energy provide different signatures, and detector technologies respond to different parts of that information. A detector can therefore be highly sensitive to one type of fire and comparatively slow for another. Selection begins with the fires and environmental conditions expected in the protected space.&amp;lt;ref name=&amp;quot;S-fd76472e02&amp;quot;&amp;gt;Schifiliti et al. (2002), pp. 4-3.&amp;lt;/ref&amp;gt;&amp;lt;ref name=&amp;quot;F-e5e5ba2507&amp;quot;&amp;gt;Cote et al. (2008), chapter 14.2, pp. 14-15.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;A fire signature is a measurable effect associated with combustion. Heat, suspended smoke particles and radiant energy provide different signatures, and detector technologies respond to different parts of that information. A detector can therefore be highly sensitive to one type of fire and comparatively slow for another. Selection begins with the fires and environmental conditions expected in the protected space.&amp;lt;ref name=&amp;quot;S-fd76472e02&amp;quot;&amp;gt;Schifiliti et al. (2002), pp. 4-3.&amp;lt;/ref&amp;gt;&amp;lt;ref name=&amp;quot;F-e5e5ba2507&amp;quot;&amp;gt;Cote et al. (2008), chapter 14.2, pp. 14-15.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-deleted&quot;&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;[[File:fse-rate-of-rise-heat-detector-v2.svg|thumb|upright=1.5|alt=Explain the mechanism supporting rate-of-rise heat detector.|Explain the mechanism supporting rate-of-rise heat detector. Based on Schifiliti et al. (2002), pp. 4-3; Cote et al. (2008), chapter 14.2, pp. 14-15; Cote et al. (2008), chapter 14.2, pp. 14-15–14-19.]]&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Flaming and smouldering fires illustrate this distinction. A rapidly flaming fire can produce substantial heat and a strong radiation signal. A smouldering fire can produce smoke without a visible flame and with relatively little heat. A detection strategy based only on heat or visible flame may consequently respond differently from one based on smoke. The relevant comparison is response to the selected scenario, rather than an abstract ranking of all detectors.&amp;lt;ref name=&amp;quot;F-b20170c94c&amp;quot;&amp;gt;Cote et al. (2008), chapter 14.2, pp. 14-15–14-19.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Flaming and smouldering fires illustrate this distinction. A rapidly flaming fire can produce substantial heat and a strong radiation signal. A smouldering fire can produce smoke without a visible flame and with relatively little heat. A detection strategy based only on heat or visible flame may consequently respond differently from one based on smoke. The relevant comparison is response to the selected scenario, rather than an abstract ranking of all detectors.&amp;lt;ref name=&amp;quot;F-b20170c94c&amp;quot;&amp;gt;Cote et al. (2008), chapter 14.2, pp. 14-15–14-19.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l61&quot;&gt;Line 61:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 63:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Inspection, testing and continuing performance ==&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Inspection, testing and continuing performance ==&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Inspection, testing and maintenance answer different questions about the installation. Inspection can reveal damage, obstruction, unsuitable surroundings or changes in the protected space. Functional testing demonstrates an intended response under a stated test condition. Maintenance addresses defects and deterioration so that the installation can continue to perform its specified functions. The handbook treats these activities as part of the original protection design.&amp;lt;ref name=&amp;quot;F-c183541efa&amp;quot;&amp;gt;Cote et al. (2008), chapter 14.5, pp. 14-53–14-54, 14-61–14-62.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Inspection, testing and maintenance answer different questions about the installation. Inspection can reveal damage, obstruction, unsuitable surroundings or changes in the protected space. Functional testing demonstrates an intended response under a stated test condition. Maintenance addresses defects and deterioration so that the installation can continue to perform its specified functions. The handbook treats these activities as part of the original protection design.&amp;lt;ref name=&amp;quot;F-c183541efa&amp;quot;&amp;gt;Cote et al. (2008), chapter 14.5, pp. 14-53–14-54, 14-61–14-62.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-deleted&quot;&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;[[File:fse-rate-of-rise-heat-detector-v3.svg|thumb|upright=1.5|alt=Distinguish complementary evidence needed to assess rate-of-rise heat detector.|Distinguish complementary evidence needed to assess rate-of-rise heat detector. Based on Cote et al. (2008), chapter 14.5, pp. 14-53–14-54, 14-61–14-62; Cote et al. (2008), chapter 14.5, pp. 14-61–14-62; Cote et al. (2008), chapter 14.2, pp. 14-28.]]&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Acceptance testing checks the installed arrangement against its intended sequence of operation. Changes to hardware, wiring or software can require reacceptance testing because they can affect previously demonstrated functions. The scope of the assessment depends on the change and its consequences. Records make the original arrangement, subsequent changes and observed performance available for later comparison.&amp;lt;ref name=&amp;quot;F-d70f9bf924&amp;quot;&amp;gt;Cote et al. (2008), chapter 14.5, pp. 14-61–14-62.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Acceptance testing checks the installed arrangement against its intended sequence of operation. Changes to hardware, wiring or software can require reacceptance testing because they can affect previously demonstrated functions. The scope of the assessment depends on the change and its consequences. Records make the original arrangement, subsequent changes and observed performance available for later comparison.&amp;lt;ref name=&amp;quot;F-d70f9bf924&amp;quot;&amp;gt;Cote et al. (2008), chapter 14.5, pp. 14-61–14-62.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;

&lt;!-- diff cache key firesb_pjbsiy42-wiki_:diff:1.41:old-3767:rev-6124:php=table --&gt;
&lt;/table&gt;</summary>
		<author><name>Peter</name></author>
	</entry>
	<entry>
		<id>https://fire-safety.academy/w/index.php?title=Rate-of-rise_heat_detector&amp;diff=3767&amp;oldid=prev</id>
		<title>Thomas: New FSE wiki article: Rate-of-rise heat detector (written by GPT-6)</title>
		<link rel="alternate" type="text/html" href="https://fire-safety.academy/w/index.php?title=Rate-of-rise_heat_detector&amp;diff=3767&amp;oldid=prev"/>
		<updated>2026-11-07T21:36:51Z</updated>

		<summary type="html">&lt;p&gt;New FSE wiki article: Rate-of-rise heat detector (written by GPT-6)&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;A &amp;#039;&amp;#039;&amp;#039;rate-of-rise [[Heat detector|heat detector]]&amp;#039;&amp;#039;&amp;#039; responds when temperature increases faster than a specified rate. It measures a change over time rather than only whether a fixed temperature has been reached. The Fire Protection Handbook describes pneumatic and electronic forms, including devices that combine rate-of-rise and fixed-temperature operation.&amp;lt;ref name=&amp;quot;F-6f102e82c9&amp;quot;&amp;gt;Cote et al. (2008), chapter 14.2, pp. 14-17–14-19.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
The detector is a type of heat detector and can act as an [[Initiating device|initiating device]] in an alarm installation. Its response depends on the heating history produced by the fire and the surrounding airflow. A [[Ceiling jet|ceiling jet]] can deliver that heat, while [[Detector spacing|detector spacing]] influences the location at which the device experiences it.&amp;lt;ref name=&amp;quot;F-bb5da34c80&amp;quot;&amp;gt;Cote et al. (2008), chapter 14.2, pp. 14-16–14-19, 14-27.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
[[Detector activation time]] is therefore not specified by the rate threshold alone. [[Response time index]] describes thermal response characteristics used in modelling, while rate-compensation and rate-of-rise mechanisms remain distinct concepts. A detector&amp;#039;s operating designation has to be interpreted alongside its actual sensing arrangement.&amp;lt;ref name=&amp;quot;F-6a5cb7157e&amp;quot;&amp;gt;Cote et al. (2008), chapter 14.2, pp. 14-17–14-19, 14-27.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== Sensing principle and application ==&lt;br /&gt;
A pneumatic device contains air that expands when heated. A restricted vent allows slow changes to equalise with the surroundings. When heating is sufficiently rapid, expansion exceeds the venting rate and pressure moves a diaphragm that operates contacts. The mechanism therefore compares heating with pressure equalisation rather than directly measuring a flame.&amp;lt;ref name=&amp;quot;F-4d4078b9f3&amp;quot;&amp;gt;Cote et al. (2008), chapter 14.2, pp. 14-17–14-18.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
An electronic arrangement can compare thermistors that respond differently to changes in ambient temperature. The exposed sensing element responds more rapidly than the reference element. Processing interprets the difference as a rate-related condition. The handbook describes fixed-temperature backup as a means of retaining response to slower heating that does not reach the rate threshold.&amp;lt;ref name=&amp;quot;F-d75465fddb&amp;quot;&amp;gt;Cote et al. (2008), chapter 14.2, pp. 14-19.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
A rate-compensation device has another objective. Its construction compensates for thermal lag so that operation corresponds more closely to a specified surrounding temperature. It is consequently not a synonym for rate-of-rise detection. The two mechanisms consequently require separate interpretation when selecting a detector.&amp;lt;ref name=&amp;quot;F-7a0dfd6628&amp;quot;&amp;gt;Cote et al. (2008), chapter 14.2, pp. 14-17.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Rapid non-fire temperature changes can also produce the relevant stimulus. The handbook identifies heating equipment, kitchens and other variable-temperature environments as application concerns. Selection therefore considers both expected fire heating and ordinary operation of the space. A rate-sensitive function cannot independently determine why the temperature changed.&amp;lt;ref name=&amp;quot;F-6f102e82c9&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== Fire signatures and detector selection ==&lt;br /&gt;
A fire signature is a measurable effect associated with combustion. Heat, suspended smoke particles and radiant energy provide different signatures, and detector technologies respond to different parts of that information. A detector can therefore be highly sensitive to one type of fire and comparatively slow for another. Selection begins with the fires and environmental conditions expected in the protected space.&amp;lt;ref name=&amp;quot;S-fd76472e02&amp;quot;&amp;gt;Schifiliti et al. (2002), pp. 4-3.&amp;lt;/ref&amp;gt;&amp;lt;ref name=&amp;quot;F-e5e5ba2507&amp;quot;&amp;gt;Cote et al. (2008), chapter 14.2, pp. 14-15.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Flaming and smouldering fires illustrate this distinction. A rapidly flaming fire can produce substantial heat and a strong radiation signal. A smouldering fire can produce smoke without a visible flame and with relatively little heat. A detection strategy based only on heat or visible flame may consequently respond differently from one based on smoke. The relevant comparison is response to the selected scenario, rather than an abstract ranking of all detectors.&amp;lt;ref name=&amp;quot;F-b20170c94c&amp;quot;&amp;gt;Cote et al. (2008), chapter 14.2, pp. 14-15–14-19.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Non-fire processes can resemble the signature that a detector is intended to recognise. Airborne dust, process aerosols and normal temperature changes can therefore influence selection and location. Increasing sensitivity can shorten response to a fire while increasing response to unwanted stimuli. The handbook describes selection as a balance between useful sensitivity and discrimination under the expected environmental conditions.&amp;lt;ref name=&amp;quot;F-5dba1efe59&amp;quot;&amp;gt;Cote et al. (2008), chapter 14.2, pp. 14-15, 14-26.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
A combined detector does not necessarily treat every sensor in the same way. Some combinations contain independently operating sensing elements. Multicriteria equipment instead combines information through a processing algorithm before deciding whether to signal. The resulting response belongs to that particular sensing and processing arrangement. The presence of several sensors does not establish a universal response time or remove the need to examine nuisance conditions.&amp;lt;ref name=&amp;quot;F-5ea64bae68&amp;quot;&amp;gt;Cote et al. (2008), chapter 14.2, pp. 14-23.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== Smoke sensing and signal interpretation ==&lt;br /&gt;
Ionisation and photoelectric detectors measure different effects of suspended particles. An ionisation chamber maintains a small electrical current through ionised air. Smoke particles reduce the mobility of charged species and change the chamber&amp;#039;s conductivity. A photoelectric detector instead measures the effect of particles on light. Its optical arrangement can respond to scattered light or to attenuation along a beam.&amp;lt;ref name=&amp;quot;F-0269bd4d24&amp;quot;&amp;gt;Cote et al. (2008), chapter 14.2, pp. 14-19–14-21.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
In a light-scattering detector, the source and receiver are arranged so that the receiver normally sees little direct source light. Particles entering the sensing region scatter some light towards the receiver. In an obscuration detector, smoke reduces the amount of light reaching the receiver along an established path. These are distinct optical arrangements, even though both are described as photoelectric detection.&amp;lt;ref name=&amp;quot;F-31879b8553&amp;quot;&amp;gt;Cote et al. (2008), chapter 14.2, pp. 14-21–14-22.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
The handbook associates ionisation response with particle number and photoelectric response with optical properties. It reports different responses to flaming and smouldering test fires, while also explaining that distance and smoke development influence the comparison. Particle properties and transport therefore matter alongside nominal detector sensitivity. A claim about one tested fire cannot establish which technology will respond first in every building scenario.&amp;lt;ref name=&amp;quot;F-5a30bdeee0&amp;quot;&amp;gt;Cote et al. (2008), chapter 14.2, pp. 14-19–14-22, 14-27.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Analogue reporting and addressability add different capabilities. Analogue information describes a measured condition beyond a simple normal-or-alarm state. Addressability identifies the individual reporting device. Processing can use this information for sensitivity management, diagnostics and locating an event. Compensation for gradual contamination nevertheless cannot demonstrate that smoke reaches the sensing chamber. Physical inspection and functional testing remain separate parts of performance assessment.&amp;lt;ref name=&amp;quot;F-aab91cceb4&amp;quot;&amp;gt;Cote et al. (2008), chapter 14.2, pp. 14-19–14-20, 14-28.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== Transport, location and coverage ==&lt;br /&gt;
A detector responds to conditions at its sensing location, which may differ from conditions beside the fire. A plume carries hot combustion products upwards and entrains surrounding air. The resulting mixture becomes cooler and more dilute as it travels. Beneath a ceiling, the flow can then spread horizontally before reaching a detector. Ceiling height and horizontal separation therefore influence the available signal.&amp;lt;ref name=&amp;quot;S-21ffe36703&amp;quot;&amp;gt;Schifiliti et al. (2002), pp. 4-3–4-4.&amp;lt;/ref&amp;gt;&amp;lt;ref name=&amp;quot;F-306a4a9de8&amp;quot;&amp;gt;Cote et al. (2008), chapter 14.2, pp. 14-26–14-27.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Beams, partitions and other obstructions can redirect or restrict that movement. Building ventilation can also transport smoke or bathe a detector in relatively clean supply air. For low-energy fires, the airflow produced by building services can be especially relevant to where smoke travels. A regular detector grid is consequently a layout arrangement, not a direct measurement of response time.&amp;lt;ref name=&amp;quot;F-306a4a9de8&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Different detection methods impose different transport conditions. An aspirating system draws sampled air through pipework, introducing transport time and possible dilution between sampling ports. A projected beam measures smoke along an optical path rather than at a single point. Video detection analyses an image and therefore does not require smoke to enter a local sensing chamber. Each arrangement introduces its own limitations concerning coverage, obstruction and interpretation.&amp;lt;ref name=&amp;quot;F-724337824e&amp;quot;&amp;gt;Cote et al. (2008), chapter 14.2, pp. 14-21–14-23.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Duct detection has a different purpose from open-area detection. Smoke in a duct may be diluted by air returning from other rooms, and it may not reach the detector when the fan is stopped. The handbook consequently distinguishes control of smoke circulation from protection of an occupied space itself. Coverage is assessed against the function being claimed, including the relevant operating and non-operating states of the ventilation system.&amp;lt;ref name=&amp;quot;F-97c29afec9&amp;quot;&amp;gt;Cote et al. (2008), chapter 14.2, pp. 14-27.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== Heat response and the meaning of spacing ==&lt;br /&gt;
Heat detectors respond through a sensing element whose temperature changes as heat is transferred to it. A fixed-temperature device signals when that element reaches its operating condition. The surrounding gas can already be hotter because the element takes time to heat. This difference is thermal lag, and it explains why a rated temperature alone does not determine activation time.&amp;lt;ref name=&amp;quot;F-db91827158&amp;quot;&amp;gt;Cote et al. (2008), chapter 14.2, pp. 14-16–14-17.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
A rate-of-rise detector responds to a sufficiently rapid temperature increase. A rate-compensation detector has a different purpose: it reduces the effect of thermal lag on operation near a specified ambient temperature. The two descriptions are therefore not interchangeable. A combination detector may include both rate-of-rise and fixed-temperature functions so that different heating histories can produce operation.&amp;lt;ref name=&amp;quot;F-6f102e82c9&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
The handbook distinguishes the test basis of heat-detector spacing from the conventional nominal spacing used for smoke detectors. Listed heat-detector spacing relates to a defined fire-test arrangement and response comparison. It does not mean that a fire of any size will be detected within a fixed time anywhere in the resulting area. Ceiling height, ambient conditions, fire growth and the detector&amp;#039;s thermal response still influence the result.&amp;lt;ref name=&amp;quot;S-21ffe36703&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;F-97c29afec9&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Performance assessment therefore combines the fire environment with the sensing element&amp;#039;s response. A model can estimate gas temperature and velocity near a detector and then estimate heating of the element. The assumptions must match the type of fire and enclosure being represented. The handbook cautions that a plume-based approach developed for flaming fires cannot simply be transferred to low-energy smouldering scenarios.&amp;lt;ref name=&amp;quot;F-97c29afec9&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;S-6654fefff7&amp;quot;&amp;gt;Schifiliti et al. (2002), pp. 4-4.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== Protection objectives and response time ==&lt;br /&gt;
A detection and alarm design begins with the outcome that the protection is intended to achieve. Life safety, property protection and continuity of a building&amp;#039;s activities can require different responses to the same fire. A warning intended to support evacuation has to arrive while useful escape time remains. Protection of sensitive equipment may instead demand detection before a small fire produces unacceptable contamination. These objectives influence the devices, processing and response arrangements chosen for the installation.&amp;lt;ref name=&amp;quot;S-4be2477a1d&amp;quot;&amp;gt;Schifiliti et al. (2002), pp. 4-2–4-3.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
The response is a sequence rather than a single event. Products of combustion must reach an appropriate sensor, the system must recognise its input, and the intended action must follow. A person receiving a warning may then need time to interpret it and begin moving. For an automatic protective function, the corresponding delay includes operation of the connected equipment. Treating detector operation as the end of the process therefore omits part of the protection mechanism.&amp;lt;ref name=&amp;quot;S-4be2477a1d&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;V-9cf08291b8&amp;quot;&amp;gt;Van Rossum (2027), §7.2–7.3.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
The SFPE design approach separates delays associated with transport from delays associated with processing and subsequent response. Transport depends on the fire, distance and enclosure geometry. Processing delays depend on the selected system and its configuration. This distinction helps identify whether an improvement requires a different sensor location, different processing or a different response arrangement.&amp;lt;ref name=&amp;quot;S-4be2477a1d&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
A single favourable fire scenario does not establish performance for every possible fire. Different fuels, locations and growth histories can change which signature reaches the system first. Assessment therefore compares plausible scenarios and the consequences of delayed or unsuccessful operation. The resulting performance claim belongs to the complete arrangement and its stated assumptions, rather than to an isolated component.&amp;lt;ref name=&amp;quot;S-4be2477a1d&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== Inspection, testing and continuing performance ==&lt;br /&gt;
Inspection, testing and maintenance answer different questions about the installation. Inspection can reveal damage, obstruction, unsuitable surroundings or changes in the protected space. Functional testing demonstrates an intended response under a stated test condition. Maintenance addresses defects and deterioration so that the installation can continue to perform its specified functions. The handbook treats these activities as part of the original protection design.&amp;lt;ref name=&amp;quot;F-c183541efa&amp;quot;&amp;gt;Cote et al. (2008), chapter 14.5, pp. 14-53–14-54, 14-61–14-62.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Acceptance testing checks the installed arrangement against its intended sequence of operation. Changes to hardware, wiring or software can require reacceptance testing because they can affect previously demonstrated functions. The scope of the assessment depends on the change and its consequences. Records make the original arrangement, subsequent changes and observed performance available for later comparison.&amp;lt;ref name=&amp;quot;F-d70f9bf924&amp;quot;&amp;gt;Cote et al. (2008), chapter 14.5, pp. 14-61–14-62.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Electrical supervision cannot identify every physical impairment. A communicating smoke detector may have an obstructed smoke-entry path, and an interface may remain electrically normal while its mechanical connection is ineffective. The handbook specifically identifies painting, covering and changed airflows as reasons for examining detectors physically. Test planning therefore includes the real stimulus and the downstream response wherever those are necessary to demonstrate the required function.&amp;lt;ref name=&amp;quot;F-527d72e812&amp;quot;&amp;gt;Cote et al. (2008), chapter 14.2, pp. 14-28.&amp;lt;/ref&amp;gt;&amp;lt;ref name=&amp;quot;F-d70f9bf924&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
The Australian part of the International Fire Engineering Guidelines, published in 2005, connects commissioning with management and maintenance throughout building use. It also identifies alterations as a possible challenge to the original engineering assumptions. A changed layout or operating procedure can invalidate an earlier assessment without causing an electrical fault. Continuing performance consequently involves reviewing both equipment condition and the circumstances in which the equipment is expected to work.&amp;lt;ref name=&amp;quot;I-abe1241982&amp;quot;&amp;gt;National Research Council of Canada et al. (2005), §0.3.2.4–0.3.2.8; pp. 0.3-6–0.3-7.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== Warning, recognition and movement ==&lt;br /&gt;
A warning reaches its life-safety objective through the response of the people who receive it. Hearing a sound or seeing a light is only the first part of that process. People must recognise its significance, interpret the situation and decide what action to take. Movement towards safety follows those earlier stages rather than occurring automatically at the instant of detection.&amp;lt;ref name=&amp;quot;V-9cf08291b8&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Van Rossum distinguishes awareness, decision-making and the actions preceding purposeful movement. Behaviour depends on perceived danger, previous experience, training, roles and the conduct of other people. The same audible signal can therefore produce different responses in different occupancies. A calculation that assigns no time to interpretation removes a part of the evacuation process described in the source.&amp;lt;ref name=&amp;quot;V-75f086b683&amp;quot;&amp;gt;Van Rossum (2027), §7.3.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Information content also matters. A simple alarm pattern identifies an emergency condition but carries little detail about its location or the required response. A voice message can convey additional instructions, provided that the message is understandable. The Fire Protection Handbook consequently treats audibility and intelligibility as separate performance questions. Greater sound output alone does not establish that a listener understands spoken instructions.&amp;lt;ref name=&amp;quot;F-9cd1c89205&amp;quot;&amp;gt;Cote et al. (2008), chapter 14.3, pp. 14-29–14-32.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
The intended audience influences the notification arrangement. Public-mode notification addresses occupants generally, while private-mode arrangements address trained people responsible for emergency actions. The handbook uses hospitals and prisons as examples where staff may mediate the response. Such arrangements depend on the defined management and assistance strategy. They cannot be evaluated solely by checking whether a warning appliance operates electrically.&amp;lt;ref name=&amp;quot;F-5996d38f18&amp;quot;&amp;gt;Cote et al. (2008), chapter 14.3, pp. 14-29–14-30.&amp;lt;/ref&amp;gt;&amp;lt;ref name=&amp;quot;I-a0c3c0da57&amp;quot;&amp;gt;National Research Council of Canada et al. (2005), §0.3.2.6; p. 0.3-6.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== See also ==&lt;br /&gt;
* [[Ionisation smoke detector]]&lt;br /&gt;
* [[Photoelectric smoke detector]]&lt;br /&gt;
* [[Video smoke detection]]&lt;br /&gt;
&lt;br /&gt;
== Notes ==&lt;br /&gt;
&amp;lt;references /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== References ==&lt;br /&gt;
* Cote, A. E., Grant, C. C., Hall, J. R., Jr., &amp;amp; Solomon, R. E. (Eds.). (2008). &amp;#039;&amp;#039;Fire Protection Handbook&amp;#039;&amp;#039; (20th ed.). National Fire Protection Association.&lt;br /&gt;
* National Research Council of Canada, International Code Council, Department of Building and Housing, &amp;amp; Australian Building Codes Board. (2005). &amp;#039;&amp;#039;International Fire Engineering Guidelines&amp;#039;&amp;#039; (2005 ed.). Australian Building Codes Board.&lt;br /&gt;
* Schifiliti, R. P., Meacham, B. J., &amp;amp; Custer, R. L. P. (2002). Design of detection systems. In P. J. DiNenno, D. Drysdale, C. L. Beyler, W. D. Walton, R. L. P. Custer, J. R. Hall, Jr., &amp;amp; J. M. Watts, Jr. (Eds.), &amp;#039;&amp;#039;SFPE Handbook of Fire Protection Engineering&amp;#039;&amp;#039; (3rd ed., chapter 4-1, pp. 4-1–4-43). National Fire Protection Association.&lt;br /&gt;
* Van Rossum, E. (2027). &amp;#039;&amp;#039;Introduction to Fire Safety Engineering&amp;#039;&amp;#039;. Fire Safety Academy.&lt;br /&gt;
&lt;br /&gt;
[[Category:Detection &amp;amp; Alarm]]&lt;/div&gt;</summary>
		<author><name>Thomas</name></author>
	</entry>
</feed>