<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://fire-safety.academy/w/index.php?action=history&amp;feed=atom&amp;title=NFPA_68</id>
	<title>NFPA 68 - Revision history</title>
	<link rel="self" type="application/atom+xml" href="https://fire-safety.academy/w/index.php?action=history&amp;feed=atom&amp;title=NFPA_68"/>
	<link rel="alternate" type="text/html" href="https://fire-safety.academy/w/index.php?title=NFPA_68&amp;action=history"/>
	<updated>2026-11-21T22:27:53Z</updated>
	<subtitle>Revision history for this page on the wiki</subtitle>
	<generator>MediaWiki 1.43.11</generator>
	<entry>
		<id>https://fire-safety.academy/w/index.php?title=NFPA_68&amp;diff=5649&amp;oldid=prev</id>
		<title>Peter: Correct errors identified in the editorial review of 9 November 2026</title>
		<link rel="alternate" type="text/html" href="https://fire-safety.academy/w/index.php?title=NFPA_68&amp;diff=5649&amp;oldid=prev"/>
		<updated>2026-11-09T15:08:14Z</updated>

		<summary type="html">&lt;p&gt;Correct errors identified in the editorial review of 9 November 2026&lt;/p&gt;
&lt;table style=&quot;background-color: #fff; color: #202122;&quot; data-mw=&quot;interface&quot;&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;tr class=&quot;diff-title&quot; lang=&quot;en&quot;&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;← Older revision&lt;/td&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;Revision as of 16:08, 9 November 2026&lt;/td&gt;
				&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l82&quot;&gt;Line 82:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 82:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&amp;lt;math display=&amp;quot;block&amp;quot;&amp;gt;A_v = \left[0.127\log_{10}K_G - 0.0567\right]P_{\mathrm{red}}^{-0.582}\,V^{2/3} + 0.175\,P_{\mathrm{red}}^{-0.572}\left(P_{\mathrm{stat}} - 0.1\right)V^{2/3}&amp;lt;/math&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&amp;lt;math display=&amp;quot;block&amp;quot;&amp;gt;A_v = \left[0.127\log_{10}K_G - 0.0567\right]P_{\mathrm{red}}^{-0.582}\,V^{2/3} + 0.175\,P_{\mathrm{red}}^{-0.572}\left(P_{\mathrm{stat}} - 0.1\right)V^{2/3}&amp;lt;/math&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Its limits are &#039;&#039;K&#039;&#039;&amp;lt;sub&amp;gt;G&amp;lt;/sub&amp;gt; up to 550 bar·m/s, &#039;&#039;P&#039;&#039;&amp;lt;sub&amp;gt;stat&amp;lt;/sub&amp;gt; up to 0.5 bar and a volume up to 1,000 m³.&amp;lt;ref name=&quot;S-18-85&quot; /&amp;gt; &#039;&#039;P&#039;&#039;&amp;lt;sub&amp;gt;red&amp;lt;/sub&amp;gt; is &lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;printed as &lt;/del&gt;2 bar and at least 0.&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;5 &lt;/del&gt;bar above &#039;&#039;P&#039;&#039;&amp;lt;sub&amp;gt;stat&amp;lt;/sub&amp;gt;.&amp;lt;ref name=&quot;S-18-85&quot; /&amp;gt; Extra terms enlarge the area for &#039;&#039;L&#039;&#039;/&#039;&#039;D&#039;&#039; between 2 and 5 and for panels heavier than a threshold mass.&amp;lt;ref name=&quot;S-18-85&quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Its limits are &#039;&#039;K&#039;&#039;&amp;lt;sub&amp;gt;G&amp;lt;/sub&amp;gt; up to 550 bar·m/s, &#039;&#039;P&#039;&#039;&amp;lt;sub&amp;gt;stat&amp;lt;/sub&amp;gt; up to 0.5 bar and a volume up to 1,000 m³.&amp;lt;ref name=&quot;S-18-85&quot; /&amp;gt; &#039;&#039;P&#039;&#039;&amp;lt;sub&amp;gt;red&amp;lt;/sub&amp;gt; is &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;limited to &lt;/ins&gt;2 bar and at least 0.&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;05 &lt;/ins&gt;bar above &#039;&#039;P&#039;&#039;&amp;lt;sub&amp;gt;stat&amp;lt;/sub&amp;gt;.&amp;lt;ref name=&quot;S-18-85&quot; /&amp;gt; Extra terms enlarge the area for &#039;&#039;L&#039;&#039;/&#039;&#039;D&#039;&#039; between 2 and 5 and for panels heavier than a threshold mass.&amp;lt;ref name=&quot;S-18-85&quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;For dusts and hybrid mixtures, the equation applies to enclosures stronger than 0.1 bar with &amp;#039;&amp;#039;L&amp;#039;&amp;#039;/&amp;#039;&amp;#039;D&amp;#039;&amp;#039; up to 2.&amp;lt;ref name=&amp;quot;S-18-86&amp;quot; /&amp;gt; The initial pressure is 1 bar absolute (±0.2 bar):&amp;lt;ref name=&amp;quot;S-18-86&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;For dusts and hybrid mixtures, the equation applies to enclosures stronger than 0.1 bar with &amp;#039;&amp;#039;L&amp;#039;&amp;#039;/&amp;#039;&amp;#039;D&amp;#039;&amp;#039; up to 2.&amp;lt;ref name=&amp;quot;S-18-86&amp;quot; /&amp;gt; The initial pressure is 1 bar absolute (±0.2 bar):&amp;lt;ref name=&amp;quot;S-18-86&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;

&lt;!-- diff cache key firesb_pjbsiy42-wiki_:diff:1.41:old-5613:rev-5649:php=table --&gt;
&lt;/table&gt;</summary>
		<author><name>Peter</name></author>
	</entry>
	<entry>
		<id>https://fire-safety.academy/w/index.php?title=NFPA_68&amp;diff=5613&amp;oldid=prev</id>
		<title>Emma: Add SVG figures fse-nfpa-68-v1.svg, fse-nfpa-68-v2.svg, fse-nfpa-68-v3.svg, fse-nfpa-68-v4.svg, fse-nfpa-68-v5.svg (list-2 visual plan)</title>
		<link rel="alternate" type="text/html" href="https://fire-safety.academy/w/index.php?title=NFPA_68&amp;diff=5613&amp;oldid=prev"/>
		<updated>2026-11-09T08:17:32Z</updated>

		<summary type="html">&lt;p&gt;Add SVG figures fse-nfpa-68-v1.svg, fse-nfpa-68-v2.svg, fse-nfpa-68-v3.svg, fse-nfpa-68-v4.svg, fse-nfpa-68-v5.svg (list-2 visual plan)&lt;/p&gt;
&lt;table style=&quot;background-color: #fff; color: #202122;&quot; data-mw=&quot;interface&quot;&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;tr class=&quot;diff-title&quot; lang=&quot;en&quot;&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;← Older revision&lt;/td&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;Revision as of 09:17, 9 November 2026&lt;/td&gt;
				&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l7&quot;&gt;Line 7:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 7:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Work at the US Bureau of Mines and larger test programmes in Great Britain, Germany and Switzerland increased the evidence during the late 1960s and early 1970s. This led to the 1974 edition, printed in the handbook as &amp;#039;&amp;#039;Guide for Venting of Deflagration&amp;#039;&amp;#039;.&amp;lt;ref name=&amp;quot;S-18-79&amp;quot; /&amp;gt; The procedures for enclosures of 1.5 psig (10.4 kPa) or stronger rest mainly on the work of Bartknecht and his associates.&amp;lt;ref name=&amp;quot;S6-148&amp;quot;&amp;gt;Schwab (2008c), p. 6-148.&amp;lt;/ref&amp;gt; Those for weaker structures are based on the work of Swift and Epstein.&amp;lt;ref name=&amp;quot;S6-148&amp;quot; /&amp;gt; The 1998 version still had the title &amp;#039;&amp;#039;Guide for Venting of Deflagrations&amp;#039;&amp;#039;.&amp;lt;ref name=&amp;quot;Z02-3-420&amp;quot;&amp;gt;Zalosh (2002), p. 3-420.&amp;lt;/ref&amp;gt; Its equation for dusts in high-strength enclosures was then the same as in the VDI 3673 guideline, and the technical committee had proposed a new dust equation for the 2002 edition.&amp;lt;ref name=&amp;quot;Z02-3-416&amp;quot;&amp;gt;Zalosh (2002), p. 3-416.&amp;lt;/ref&amp;gt; By 2007 the document had become a standard, titled &amp;#039;&amp;#039;Standard on Explosion Protection by Deflagration Venting&amp;#039;&amp;#039;.&amp;lt;ref name=&amp;quot;S-18-79&amp;quot; /&amp;gt; In that edition, data on the fundamental burning velocity can be used to set the venting parameter for more individual fuels than in earlier editions.&amp;lt;ref name=&amp;quot;S-18-85&amp;quot;&amp;gt;Schwab (2008b), p. 18-85.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Work at the US Bureau of Mines and larger test programmes in Great Britain, Germany and Switzerland increased the evidence during the late 1960s and early 1970s. This led to the 1974 edition, printed in the handbook as &amp;#039;&amp;#039;Guide for Venting of Deflagration&amp;#039;&amp;#039;.&amp;lt;ref name=&amp;quot;S-18-79&amp;quot; /&amp;gt; The procedures for enclosures of 1.5 psig (10.4 kPa) or stronger rest mainly on the work of Bartknecht and his associates.&amp;lt;ref name=&amp;quot;S6-148&amp;quot;&amp;gt;Schwab (2008c), p. 6-148.&amp;lt;/ref&amp;gt; Those for weaker structures are based on the work of Swift and Epstein.&amp;lt;ref name=&amp;quot;S6-148&amp;quot; /&amp;gt; The 1998 version still had the title &amp;#039;&amp;#039;Guide for Venting of Deflagrations&amp;#039;&amp;#039;.&amp;lt;ref name=&amp;quot;Z02-3-420&amp;quot;&amp;gt;Zalosh (2002), p. 3-420.&amp;lt;/ref&amp;gt; Its equation for dusts in high-strength enclosures was then the same as in the VDI 3673 guideline, and the technical committee had proposed a new dust equation for the 2002 edition.&amp;lt;ref name=&amp;quot;Z02-3-416&amp;quot;&amp;gt;Zalosh (2002), p. 3-416.&amp;lt;/ref&amp;gt; By 2007 the document had become a standard, titled &amp;#039;&amp;#039;Standard on Explosion Protection by Deflagration Venting&amp;#039;&amp;#039;.&amp;lt;ref name=&amp;quot;S-18-79&amp;quot; /&amp;gt; In that edition, data on the fundamental burning velocity can be used to set the venting parameter for more individual fuels than in earlier editions.&amp;lt;ref name=&amp;quot;S-18-85&amp;quot;&amp;gt;Schwab (2008b), p. 18-85.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-deleted&quot;&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;[[File:fse-nfpa-68-v5.svg|thumb|upright=1.5|alt=Horizontal timeline of NFPA 68 from 1945 to 2007 with six labelled milestones|Development of NFPA 68 from the tentative 1945 standard to the 2007 standard.]]&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Scope and definitions ==&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Scope and definitions ==&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l72&quot;&gt;Line 72:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 73:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&amp;#039;&amp;#039;&amp;#039;Worked example.&amp;#039;&amp;#039;&amp;#039; Zalosh (2002) sizes a vent for a 4 m × 4 m × 3 m room with a worst-case butane–air mixture.&amp;lt;ref name=&amp;quot;Z02-3-416&amp;quot; /&amp;gt; The damage threshold is 1.0 psig and the vent opens at 0.2 psig.&amp;lt;ref name=&amp;quot;Z02-3-416&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&amp;#039;&amp;#039;&amp;#039;Worked example.&amp;#039;&amp;#039;&amp;#039; Zalosh (2002) sizes a vent for a 4 m × 4 m × 3 m room with a worst-case butane–air mixture.&amp;lt;ref name=&amp;quot;Z02-3-416&amp;quot; /&amp;gt; The damage threshold is 1.0 psig and the vent opens at 0.2 psig.&amp;lt;ref name=&amp;quot;Z02-3-416&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-deleted&quot;&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;[[File:fse-nfpa-68-v2.svg|thumb|upright=1.5|alt=Rising curve of venting parameter C against burning velocity from 0 to 60 cm/s with points for methane, n-butane and propane|Venting parameter C for low-strength enclosures as a function of fundamental burning velocity (2007 method).]]&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The internal surface area is 2 × (4 × 4 + 4 × 3 + 4 × 3) = 80 m².&amp;lt;ref name=&amp;quot;Z02-3-416&amp;quot; /&amp;gt; With &amp;#039;&amp;#039;S&amp;#039;&amp;#039;&amp;lt;sub&amp;gt;u&amp;lt;/sub&amp;gt; = 45 cm/s for &amp;#039;&amp;#039;n&amp;#039;&amp;#039;-butane, the equation gives &amp;#039;&amp;#039;C&amp;#039;&amp;#039; = 0.0498 bar&amp;lt;sup&amp;gt;1/2&amp;lt;/sup&amp;gt;.&amp;lt;ref name=&amp;quot;S-18-82&amp;quot; /&amp;gt; With &amp;#039;&amp;#039;P&amp;#039;&amp;#039;&amp;lt;sub&amp;gt;red&amp;lt;/sub&amp;gt; = 1.0 psi = 0.0689 bar, the vent area is 0.0498 × 80 / √0.0689 ≈ 15.2 m², about one-fifth of the internal surface area. The 1998 method that Zalosh (2002) used, with &amp;#039;&amp;#039;C&amp;#039;&amp;#039; = 0.17 psi&amp;lt;sup&amp;gt;1/2&amp;lt;/sup&amp;gt; for gases with a burning velocity below 60 cm/s, gave 13.6 m² for the same room.&amp;lt;ref name=&amp;quot;Z02-3-416&amp;quot; /&amp;gt; The 2007 equation therefore asks for about 11 % more vent area in this case.&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The internal surface area is 2 × (4 × 4 + 4 × 3 + 4 × 3) = 80 m².&amp;lt;ref name=&amp;quot;Z02-3-416&amp;quot; /&amp;gt; With &amp;#039;&amp;#039;S&amp;#039;&amp;#039;&amp;lt;sub&amp;gt;u&amp;lt;/sub&amp;gt; = 45 cm/s for &amp;#039;&amp;#039;n&amp;#039;&amp;#039;-butane, the equation gives &amp;#039;&amp;#039;C&amp;#039;&amp;#039; = 0.0498 bar&amp;lt;sup&amp;gt;1/2&amp;lt;/sup&amp;gt;.&amp;lt;ref name=&amp;quot;S-18-82&amp;quot; /&amp;gt; With &amp;#039;&amp;#039;P&amp;#039;&amp;#039;&amp;lt;sub&amp;gt;red&amp;lt;/sub&amp;gt; = 1.0 psi = 0.0689 bar, the vent area is 0.0498 × 80 / √0.0689 ≈ 15.2 m², about one-fifth of the internal surface area. The 1998 method that Zalosh (2002) used, with &amp;#039;&amp;#039;C&amp;#039;&amp;#039; = 0.17 psi&amp;lt;sup&amp;gt;1/2&amp;lt;/sup&amp;gt; for gases with a burning velocity below 60 cm/s, gave 13.6 m² for the same room.&amp;lt;ref name=&amp;quot;Z02-3-416&amp;quot; /&amp;gt; The 2007 equation therefore asks for about 11 % more vent area in this case.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l105&quot;&gt;Line 105:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 107:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&amp;#039;&amp;#039;&amp;#039;Worked example.&amp;#039;&amp;#039;&amp;#039; A 50 m³ compact enclosure (&amp;#039;&amp;#039;L&amp;#039;&amp;#039;/&amp;#039;&amp;#039;D&amp;#039;&amp;#039; ≤ 2) handles wheat flour with &amp;#039;&amp;#039;P&amp;#039;&amp;#039;&amp;lt;sub&amp;gt;max&amp;lt;/sub&amp;gt; = 8.3 bar and &amp;#039;&amp;#039;K&amp;#039;&amp;#039;&amp;lt;sub&amp;gt;St&amp;lt;/sub&amp;gt; = 87 bar·m/s.&amp;lt;ref name=&amp;quot;S6-146&amp;quot; /&amp;gt; Its weakest element withstands 0.75 bar, so with a DLF of 1.5 the design value is &amp;#039;&amp;#039;P&amp;#039;&amp;#039;&amp;lt;sub&amp;gt;red&amp;lt;/sub&amp;gt; = 0.50 bar.&amp;lt;ref name=&amp;quot;S-18-84&amp;quot; /&amp;gt; With a vent of &amp;#039;&amp;#039;P&amp;#039;&amp;#039;&amp;lt;sub&amp;gt;stat&amp;lt;/sub&amp;gt; = 0.1 bar, the three factors are 1.072, 50&amp;lt;sup&amp;gt;0.75&amp;lt;/sup&amp;gt; = 18.8 and √(8.3/0.50 − 1) = 3.95. The vent area is 10&amp;lt;sup&amp;gt;−4&amp;lt;/sup&amp;gt; × 1.072 × 87 × 18.8 × 3.95 = 0.692 m², rounded up to 0.70 m². A vent cover that opens at 0.2 bar instead raises the area to 0.77 m², and an &amp;#039;&amp;#039;L&amp;#039;&amp;#039;/&amp;#039;&amp;#039;D&amp;#039;&amp;#039; of 4 with the 0.1 bar vent raises it to about 1.25 m².&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&amp;#039;&amp;#039;&amp;#039;Worked example.&amp;#039;&amp;#039;&amp;#039; A 50 m³ compact enclosure (&amp;#039;&amp;#039;L&amp;#039;&amp;#039;/&amp;#039;&amp;#039;D&amp;#039;&amp;#039; ≤ 2) handles wheat flour with &amp;#039;&amp;#039;P&amp;#039;&amp;#039;&amp;lt;sub&amp;gt;max&amp;lt;/sub&amp;gt; = 8.3 bar and &amp;#039;&amp;#039;K&amp;#039;&amp;#039;&amp;lt;sub&amp;gt;St&amp;lt;/sub&amp;gt; = 87 bar·m/s.&amp;lt;ref name=&amp;quot;S6-146&amp;quot; /&amp;gt; Its weakest element withstands 0.75 bar, so with a DLF of 1.5 the design value is &amp;#039;&amp;#039;P&amp;#039;&amp;#039;&amp;lt;sub&amp;gt;red&amp;lt;/sub&amp;gt; = 0.50 bar.&amp;lt;ref name=&amp;quot;S-18-84&amp;quot; /&amp;gt; With a vent of &amp;#039;&amp;#039;P&amp;#039;&amp;#039;&amp;lt;sub&amp;gt;stat&amp;lt;/sub&amp;gt; = 0.1 bar, the three factors are 1.072, 50&amp;lt;sup&amp;gt;0.75&amp;lt;/sup&amp;gt; = 18.8 and √(8.3/0.50 − 1) = 3.95. The vent area is 10&amp;lt;sup&amp;gt;−4&amp;lt;/sup&amp;gt; × 1.072 × 87 × 18.8 × 3.95 = 0.692 m², rounded up to 0.70 m². A vent cover that opens at 0.2 bar instead raises the area to 0.77 m², and an &amp;#039;&amp;#039;L&amp;#039;&amp;#039;/&amp;#039;&amp;#039;D&amp;#039;&amp;#039; of 4 with the 0.1 bar vent raises it to about 1.25 m².&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-deleted&quot;&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;[[File:fse-nfpa-68-v3.svg|thumb|upright=1.5|alt=Two falling curves of vent area against reduced pressure for a 50 cubic metre wheat flour enclosure, for vent opening pressures 0.1 and 0.2 bar|Required vent area for a 50 m³ wheat flour enclosure (KSt 87 bar·m/s, Pmax 8.3 bar) from the 2007 dust equation.]]&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;As a check, Zalosh (2002) sized vents for a 400 m³ electrostatic precipitator in a power plant firing bituminous coal (&amp;#039;&amp;#039;K&amp;#039;&amp;#039;&amp;lt;sub&amp;gt;St&amp;lt;/sub&amp;gt; = 59 bar·m/s, &amp;#039;&amp;#039;P&amp;#039;&amp;#039;&amp;lt;sub&amp;gt;max&amp;lt;/sub&amp;gt; = 9.1 bar).&amp;lt;ref name=&amp;quot;Z02-3-416-417&amp;quot;&amp;gt;Zalosh (2002), pp. 3-416–3-417.&amp;lt;/ref&amp;gt; With &amp;#039;&amp;#039;P&amp;#039;&amp;#039;&amp;lt;sub&amp;gt;red&amp;lt;/sub&amp;gt; = 1.2 bar and &amp;#039;&amp;#039;P&amp;#039;&amp;#039;&amp;lt;sub&amp;gt;stat&amp;lt;/sub&amp;gt; = 0.4 bar, he found 1.96 m² with the equation then proposed for the 2002 edition.&amp;lt;ref name=&amp;quot;Z02-3-416-417&amp;quot; /&amp;gt; The 2007 equation above gives 1.97 m² for the same inputs. Zalosh used the damage threshold of 1.2 bar directly as &amp;#039;&amp;#039;P&amp;#039;&amp;#039;&amp;lt;sub&amp;gt;red&amp;lt;/sub&amp;gt;; with the 2007 load factor of 1.5, &amp;#039;&amp;#039;P&amp;#039;&amp;#039;&amp;lt;sub&amp;gt;red&amp;lt;/sub&amp;gt; would be 0.8 bar and the area 2.47 m².&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;As a check, Zalosh (2002) sized vents for a 400 m³ electrostatic precipitator in a power plant firing bituminous coal (&amp;#039;&amp;#039;K&amp;#039;&amp;#039;&amp;lt;sub&amp;gt;St&amp;lt;/sub&amp;gt; = 59 bar·m/s, &amp;#039;&amp;#039;P&amp;#039;&amp;#039;&amp;lt;sub&amp;gt;max&amp;lt;/sub&amp;gt; = 9.1 bar).&amp;lt;ref name=&amp;quot;Z02-3-416-417&amp;quot;&amp;gt;Zalosh (2002), pp. 3-416–3-417.&amp;lt;/ref&amp;gt; With &amp;#039;&amp;#039;P&amp;#039;&amp;#039;&amp;lt;sub&amp;gt;red&amp;lt;/sub&amp;gt; = 1.2 bar and &amp;#039;&amp;#039;P&amp;#039;&amp;#039;&amp;lt;sub&amp;gt;stat&amp;lt;/sub&amp;gt; = 0.4 bar, he found 1.96 m² with the equation then proposed for the 2002 edition.&amp;lt;ref name=&amp;quot;Z02-3-416-417&amp;quot; /&amp;gt; The 2007 equation above gives 1.97 m² for the same inputs. Zalosh used the damage threshold of 1.2 bar directly as &amp;#039;&amp;#039;P&amp;#039;&amp;#039;&amp;lt;sub&amp;gt;red&amp;lt;/sub&amp;gt;; with the 2007 load factor of 1.5, &amp;#039;&amp;#039;P&amp;#039;&amp;#039;&amp;lt;sub&amp;gt;red&amp;lt;/sub&amp;gt; would be 0.8 bar and the area 2.47 m².&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l113&quot;&gt;Line 113:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 116:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Effects outside the vent ==&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Effects outside the vent ==&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Flames and pressure waves that leave the vent must not ignite nearby combustibles or injure people.&amp;lt;ref name=&amp;quot;S-18-83&amp;quot; /&amp;gt; For a vented dust or hybrid deflagration, the handbook estimates the axial reach of the fireball &amp;#039;&amp;#039;D&amp;#039;&amp;#039; (m) from the volume &amp;#039;&amp;#039;V&amp;#039;&amp;#039; (m³) and the number of evenly distributed vents &amp;#039;&amp;#039;n&amp;#039;&amp;#039;:&amp;lt;ref name=&amp;quot;S-18-86&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Flames and pressure waves that leave the vent must not ignite nearby combustibles or injure people.&amp;lt;ref name=&amp;quot;S-18-83&amp;quot; /&amp;gt; For a vented dust or hybrid deflagration, the handbook estimates the axial reach of the fireball &amp;#039;&amp;#039;D&amp;#039;&amp;#039; (m) from the volume &amp;#039;&amp;#039;V&amp;#039;&amp;#039; (m³) and the number of evenly distributed vents &amp;#039;&amp;#039;n&amp;#039;&amp;#039;:&amp;lt;ref name=&amp;quot;S-18-86&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-deleted&quot;&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;[[File:fse-nfpa-68-v1.svg|thumb|upright=1.5|alt=Side view of a box-shaped enclosure with one wall vent, a fireball zone extending in front of the vent and a smaller side zone|Vented deflagration: the vent opens at P&amp;lt;sub&amp;gt;stat&amp;lt;/sub&amp;gt;, the enclosure pressure peaks at P&amp;lt;sub&amp;gt;red&amp;lt;/sub&amp;gt;, and the fireball reaches an axial distance D.]]&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&amp;lt;math display=&amp;quot;block&amp;quot;&amp;gt;D = K\left(\frac{V}{n}\right)^{1/3}&amp;lt;/math&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&amp;lt;math display=&amp;quot;block&amp;quot;&amp;gt;D = K\left(\frac{V}{n}\right)^{1/3}&amp;lt;/math&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l124&quot;&gt;Line 124:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 128:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Use in design and regulation ==&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Use in design and regulation ==&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Ural and Garzia (2008) name four explosion protection strategies: pressure containment, deflagration venting, deflagration suppression and deflagration isolation.&amp;lt;ref name=&amp;quot;UG-17-154&amp;quot; /&amp;gt; Venting suits cases where material toxicity and environmental contamination are not a concern and a safe discharge location exists, and it is then often a low-cost protection option.&amp;lt;ref name=&amp;quot;UG-17-155&amp;quot; /&amp;gt; NFPA 68, the VDI 3673 guideline and the European standard EN 14491 publish their correlations, so vendors, owners and authorities having jurisdiction can all check a vent size.&amp;lt;ref name=&amp;quot;UG-17-155&amp;quot; /&amp;gt; Suppression, by contrast, discharges no flame or fuel, so it suits indoor equipment and toxic materials.&amp;lt;ref name=&amp;quot;Z02-3-417&amp;quot;&amp;gt;Zalosh (2002), p. 3-417.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Ural and Garzia (2008) name four explosion protection strategies: pressure containment, deflagration venting, deflagration suppression and deflagration isolation.&amp;lt;ref name=&amp;quot;UG-17-154&amp;quot; /&amp;gt; Venting suits cases where material toxicity and environmental contamination are not a concern and a safe discharge location exists, and it is then often a low-cost protection option.&amp;lt;ref name=&amp;quot;UG-17-155&amp;quot; /&amp;gt; NFPA 68, the VDI 3673 guideline and the European standard EN 14491 publish their correlations, so vendors, owners and authorities having jurisdiction can all check a vent size.&amp;lt;ref name=&amp;quot;UG-17-155&amp;quot; /&amp;gt; Suppression, by contrast, discharges no flame or fuel, so it suits indoor equipment and toxic materials.&amp;lt;ref name=&amp;quot;Z02-3-417&amp;quot;&amp;gt;Zalosh (2002), p. 3-417.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-deleted&quot;&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;[[File:fse-nfpa-68-v4.svg|thumb|upright=1.5|alt=Flowchart with four boxes for containment, venting, suppression and isolation and decision questions leading to venting|The four explosion protection strategies and the conditions that favour deflagration venting.]]&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Many chapters of the 2008 handbook point to NFPA 68 for specific equipment in the United States. Woodworking dust collectors may be protected by venting to NFPA 68, or by venting through a listed retention and quenching device or by suppression to NFPA 69.&amp;lt;ref name=&amp;quot;C-9-22&amp;quot;&amp;gt;Cholin (2008d), p. 9-22.&amp;lt;/ref&amp;gt; Coal dust collection systems should have explosion-relief vents sized to NFPA 68.&amp;lt;ref name=&amp;quot;D-7-7&amp;quot;&amp;gt;Dungan (2008b), p. 7-7.&amp;lt;/ref&amp;gt; Deflagration relief vents on ducts that carry explosible mixtures should lead by the most direct practical route outdoors.&amp;lt;ref name=&amp;quot;L-8-14&amp;quot;&amp;gt;Lataille (2008), p. 8-14.&amp;lt;/ref&amp;gt; Refrigeration machinery rooms with flammability Class 2 or 3 refrigerants should be outdoors or of damage-limiting construction to NFPA 68.&amp;lt;ref name=&amp;quot;F-8-124&amp;quot;&amp;gt;Febo (2008), p. 8-124.&amp;lt;/ref&amp;gt; In process pipes, vents placed to Chapter 9 of NFPA 68 limit pressure and flame speed, although the flame can still travel through the whole pipe.&amp;lt;ref name=&amp;quot;UG-17-158&amp;quot;&amp;gt;Ural and Garzia (2008), p. 17-158.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Many chapters of the 2008 handbook point to NFPA 68 for specific equipment in the United States. Woodworking dust collectors may be protected by venting to NFPA 68, or by venting through a listed retention and quenching device or by suppression to NFPA 69.&amp;lt;ref name=&amp;quot;C-9-22&amp;quot;&amp;gt;Cholin (2008d), p. 9-22.&amp;lt;/ref&amp;gt; Coal dust collection systems should have explosion-relief vents sized to NFPA 68.&amp;lt;ref name=&amp;quot;D-7-7&amp;quot;&amp;gt;Dungan (2008b), p. 7-7.&amp;lt;/ref&amp;gt; Deflagration relief vents on ducts that carry explosible mixtures should lead by the most direct practical route outdoors.&amp;lt;ref name=&amp;quot;L-8-14&amp;quot;&amp;gt;Lataille (2008), p. 8-14.&amp;lt;/ref&amp;gt; Refrigeration machinery rooms with flammability Class 2 or 3 refrigerants should be outdoors or of damage-limiting construction to NFPA 68.&amp;lt;ref name=&amp;quot;F-8-124&amp;quot;&amp;gt;Febo (2008), p. 8-124.&amp;lt;/ref&amp;gt; In process pipes, vents placed to Chapter 9 of NFPA 68 limit pressure and flame speed, although the flame can still travel through the whole pipe.&amp;lt;ref name=&amp;quot;UG-17-158&amp;quot;&amp;gt;Ural and Garzia (2008), p. 17-158.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;

&lt;!-- diff cache key firesb_pjbsiy42-wiki_:diff:1.41:old-4168:rev-5613:php=table --&gt;
&lt;/table&gt;</summary>
		<author><name>Emma</name></author>
	</entry>
	<entry>
		<id>https://fire-safety.academy/w/index.php?title=NFPA_68&amp;diff=4168&amp;oldid=prev</id>
		<title>Jan: NFPA wiki: fact-check corrections (written by Claude Opus 5.5)</title>
		<link rel="alternate" type="text/html" href="https://fire-safety.academy/w/index.php?title=NFPA_68&amp;diff=4168&amp;oldid=prev"/>
		<updated>2026-11-07T22:28:22Z</updated>

		<summary type="html">&lt;p&gt;NFPA wiki: fact-check corrections (written by Claude Opus 5.5)&lt;/p&gt;
&lt;table style=&quot;background-color: #fff; color: #202122;&quot; data-mw=&quot;interface&quot;&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;tr class=&quot;diff-title&quot; lang=&quot;en&quot;&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;← Older revision&lt;/td&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;Revision as of 23:28, 7 November 2026&lt;/td&gt;
				&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l6&quot;&gt;Line 6:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 6:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The first NFPA document on explosion venting was NFPA 68-T, &amp;#039;&amp;#039;Standard on Explosion Venting&amp;#039;&amp;#039;, tentatively adopted in 1945.&amp;lt;ref name=&amp;quot;S-18-79&amp;quot; /&amp;gt; A &amp;#039;&amp;#039;Guide for Explosion Venting&amp;#039;&amp;#039; followed in 1954 and brought together the best information then available, which Schwab (2008b) describes as sparse.&amp;lt;ref name=&amp;quot;S-18-79&amp;quot; /&amp;gt; Its data had no theoretical basis, and vent area was given as a vent ratio in square feet per cubic foot of enclosure volume.&amp;lt;ref name=&amp;quot;S-18-79&amp;quot; /&amp;gt; Enclosure strength was given little weight, although strong enclosures were known to need less vent area than weak ones.&amp;lt;ref name=&amp;quot;S-18-79&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The first NFPA document on explosion venting was NFPA 68-T, &amp;#039;&amp;#039;Standard on Explosion Venting&amp;#039;&amp;#039;, tentatively adopted in 1945.&amp;lt;ref name=&amp;quot;S-18-79&amp;quot; /&amp;gt; A &amp;#039;&amp;#039;Guide for Explosion Venting&amp;#039;&amp;#039; followed in 1954 and brought together the best information then available, which Schwab (2008b) describes as sparse.&amp;lt;ref name=&amp;quot;S-18-79&amp;quot; /&amp;gt; Its data had no theoretical basis, and vent area was given as a vent ratio in square feet per cubic foot of enclosure volume.&amp;lt;ref name=&amp;quot;S-18-79&amp;quot; /&amp;gt; Enclosure strength was given little weight, although strong enclosures were known to need less vent area than weak ones.&amp;lt;ref name=&amp;quot;S-18-79&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Work at the US Bureau of Mines and larger test programmes in Great Britain, Germany and Switzerland &lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;in &lt;/del&gt;the late 1960s and early 1970s led to the 1974 edition, the &#039;&#039;Guide for Venting of &lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;Deflagrations&lt;/del&gt;&#039;&#039;.&amp;lt;ref name=&quot;S-18-79&quot; /&amp;gt; The procedures for enclosures of 1.5 psig (10.4 kPa) or stronger rest mainly on the work of Bartknecht and his associates.&amp;lt;ref name=&quot;S6-148&quot;&amp;gt;Schwab (2008c), p. 6-148.&amp;lt;/ref&amp;gt; Those for weaker structures are based on the work of Swift and Epstein.&amp;lt;ref name=&quot;S6-148&quot; /&amp;gt; The 1998 version still had the title &#039;&#039;Guide for Venting of Deflagrations&#039;&#039;.&amp;lt;ref name=&quot;Z02-3-420&quot;&amp;gt;Zalosh (2002), p. 3-420.&amp;lt;/ref&amp;gt; Its equation for dusts in high-strength enclosures was then the same as in the VDI 3673 guideline, and the technical committee had proposed a new dust equation for the 2002 edition.&amp;lt;ref name=&quot;Z02-3-416&quot;&amp;gt;Zalosh (2002), p. 3-416.&amp;lt;/ref&amp;gt; By 2007 the document had become a standard, titled &#039;&#039;Standard on Explosion Protection by Deflagration Venting&#039;&#039;.&amp;lt;ref name=&quot;S-18-79&quot; /&amp;gt; In that edition, data on the fundamental burning velocity can be used to set the venting parameter for more individual fuels than in earlier editions.&amp;lt;ref name=&quot;S-18-85&quot;&amp;gt;Schwab (2008b), p. 18-85.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Work at the US Bureau of Mines and larger test programmes in Great Britain, Germany and Switzerland &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;increased the evidence during &lt;/ins&gt;the late 1960s and early 1970s&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;. This &lt;/ins&gt;led to the 1974 edition, &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;printed in &lt;/ins&gt;the &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;handbook as &lt;/ins&gt;&#039;&#039;Guide for Venting of &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;Deflagration&lt;/ins&gt;&#039;&#039;.&amp;lt;ref name=&quot;S-18-79&quot; /&amp;gt; The procedures for enclosures of 1.5 psig (10.4 kPa) or stronger rest mainly on the work of Bartknecht and his associates.&amp;lt;ref name=&quot;S6-148&quot;&amp;gt;Schwab (2008c), p. 6-148.&amp;lt;/ref&amp;gt; Those for weaker structures are based on the work of Swift and Epstein.&amp;lt;ref name=&quot;S6-148&quot; /&amp;gt; The 1998 version still had the title &#039;&#039;Guide for Venting of Deflagrations&#039;&#039;.&amp;lt;ref name=&quot;Z02-3-420&quot;&amp;gt;Zalosh (2002), p. 3-420.&amp;lt;/ref&amp;gt; Its equation for dusts in high-strength enclosures was then the same as in the VDI 3673 guideline, and the technical committee had proposed a new dust equation for the 2002 edition.&amp;lt;ref name=&quot;Z02-3-416&quot;&amp;gt;Zalosh (2002), p. 3-416.&amp;lt;/ref&amp;gt; By 2007 the document had become a standard, titled &#039;&#039;Standard on Explosion Protection by Deflagration Venting&#039;&#039;.&amp;lt;ref name=&quot;S-18-79&quot; /&amp;gt; In that edition, data on the fundamental burning velocity can be used to set the venting parameter for more individual fuels than in earlier editions.&amp;lt;ref name=&quot;S-18-85&quot;&amp;gt;Schwab (2008b), p. 18-85.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Scope and definitions ==&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Scope and definitions ==&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l47&quot;&gt;Line 47:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 47:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Here &amp;#039;&amp;#039;P&amp;#039;&amp;#039;&amp;lt;sub&amp;gt;es&amp;lt;/sub&amp;gt; is the enclosure strength from static calculations for deformation or burst, and &amp;#039;&amp;#039;X&amp;#039;&amp;#039;&amp;lt;sub&amp;gt;m&amp;lt;/sub&amp;gt; and &amp;#039;&amp;#039;X&amp;#039;&amp;#039;&amp;lt;sub&amp;gt;s&amp;lt;/sub&amp;gt; are the dynamic and static deflections.&amp;lt;ref name=&amp;quot;S-18-84&amp;quot; /&amp;gt; Without a detailed structural response analysis, a conservative DLF of 1.5 is used, based on the weakest structural element, so that &amp;#039;&amp;#039;P&amp;#039;&amp;#039;&amp;lt;sub&amp;gt;red&amp;lt;/sub&amp;gt; reaches two-thirds of the enclosure strength.&amp;lt;ref name=&amp;quot;S-18-84&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Here &amp;#039;&amp;#039;P&amp;#039;&amp;#039;&amp;lt;sub&amp;gt;es&amp;lt;/sub&amp;gt; is the enclosure strength from static calculations for deformation or burst, and &amp;#039;&amp;#039;X&amp;#039;&amp;#039;&amp;lt;sub&amp;gt;m&amp;lt;/sub&amp;gt; and &amp;#039;&amp;#039;X&amp;#039;&amp;#039;&amp;lt;sub&amp;gt;s&amp;lt;/sub&amp;gt; are the dynamic and static deflections.&amp;lt;ref name=&amp;quot;S-18-84&amp;quot; /&amp;gt; Without a detailed structural response analysis, a conservative DLF of 1.5 is used, based on the weakest structural element, so that &amp;#039;&amp;#039;P&amp;#039;&amp;#039;&amp;lt;sub&amp;gt;red&amp;lt;/sub&amp;gt; reaches two-thirds of the enclosure strength.&amp;lt;ref name=&amp;quot;S-18-84&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;For pressure vessels built to the ASME &#039;&#039;Boiler and Pressure Vessel Code&#039;&#039;, the limit uses the maximum allowable working pressure.&amp;lt;ref name=&quot;S-18-84&quot; /&amp;gt; Where permanent deformation is accepted, &#039;&#039;P&#039;&#039;&amp;lt;sub&amp;gt;red&amp;lt;/sub&amp;gt; may reach two-thirds of that pressure times &#039;&#039;F&#039;&#039;&amp;lt;sub&amp;gt;u&amp;lt;/sub&amp;gt;, the ratio of ultimate to allowable stress.&amp;lt;ref name=&quot;S-18-84&quot; /&amp;gt; Where it is not, &#039;&#039;F&#039;&#039;&amp;lt;sub&amp;gt;y&amp;lt;/sub&amp;gt;, the ratio of yield to allowable stress, replaces &#039;&#039;F&#039;&#039;&amp;lt;sub&amp;gt;u&amp;lt;/sub&amp;gt;.&amp;lt;ref name=&quot;S-18-84&quot; /&amp;gt; For carbon steel or low-alloy stainless steel, &#039;&#039;F&#039;&#039;&amp;lt;sub&amp;gt;u&amp;lt;/sub&amp;gt; and &#039;&#039;F&#039;&#039;&amp;lt;sub&amp;gt;y&amp;lt;/sub&amp;gt; are about 3.5 and 1.75.&amp;lt;ref name=&quot;UG-17-155&quot;&amp;gt;Ural and Garzia (2008), p. 17-155.&amp;lt;/ref&amp;gt; A vessel with a maximum allowable working pressure of 1.0 bar may then reach a &#039;&#039;P&#039;&#039;&amp;lt;sub&amp;gt;red&amp;lt;/sub&amp;gt; of 2.33 bar if it may deform, or 1.17 bar if it may not. The ASME code accepts the NFPA 68 method for this purpose, so the allowable &#039;&#039;P&#039;&#039;&amp;lt;sub&amp;gt;red&amp;lt;/sub&amp;gt; can exceed the stamped working pressure.&amp;lt;ref name=&quot;S-18-84&quot; /&amp;gt;&amp;lt;ref name=&quot;UG-17-&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;155&lt;/del&gt;&quot; /&amp;gt; For comparison, Ural and Garzia (2008) give 0.3 barg (5 psig) as a common deflagration load for venting or suppression and 10 barg (150 psig) for containment.&amp;lt;ref name=&quot;UG-17-154&quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;For pressure vessels built to the ASME &#039;&#039;Boiler and Pressure Vessel Code&#039;&#039;, the limit uses the maximum allowable working pressure.&amp;lt;ref name=&quot;S-18-84&quot; /&amp;gt; Where permanent deformation is accepted, &#039;&#039;P&#039;&#039;&amp;lt;sub&amp;gt;red&amp;lt;/sub&amp;gt; may reach two-thirds of that pressure times &#039;&#039;F&#039;&#039;&amp;lt;sub&amp;gt;u&amp;lt;/sub&amp;gt;, the ratio of ultimate to allowable stress.&amp;lt;ref name=&quot;S-18-84&quot; /&amp;gt; Where it is not, &#039;&#039;F&#039;&#039;&amp;lt;sub&amp;gt;y&amp;lt;/sub&amp;gt;, the ratio of yield to allowable stress, replaces &#039;&#039;F&#039;&#039;&amp;lt;sub&amp;gt;u&amp;lt;/sub&amp;gt;.&amp;lt;ref name=&quot;S-18-84&quot; /&amp;gt; For carbon steel or low-alloy stainless steel, &#039;&#039;F&#039;&#039;&amp;lt;sub&amp;gt;u&amp;lt;/sub&amp;gt; and &#039;&#039;F&#039;&#039;&amp;lt;sub&amp;gt;y&amp;lt;/sub&amp;gt; are about 3.5 and 1.75.&amp;lt;ref name=&quot;UG-17-155&quot;&amp;gt;Ural and Garzia (2008), p. 17-155.&amp;lt;/ref&amp;gt; A vessel with a maximum allowable working pressure of 1.0 bar may then reach a &#039;&#039;P&#039;&#039;&amp;lt;sub&amp;gt;red&amp;lt;/sub&amp;gt; of 2.33 bar if it may deform, or 1.17 bar if it may not. The ASME code accepts the NFPA 68 method for this purpose, so the allowable &#039;&#039;P&#039;&#039;&amp;lt;sub&amp;gt;red&amp;lt;/sub&amp;gt; can exceed the stamped working pressure.&amp;lt;ref name=&quot;S-18-84&quot; /&amp;gt;&amp;lt;ref name=&quot;UG-17-&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;154&lt;/ins&gt;&quot; /&amp;gt; For comparison, Ural and Garzia (2008) give 0.3 barg (5 psig) as a common deflagration load for venting or suppression and 10 barg (150 psig) for containment.&amp;lt;ref name=&quot;UG-17-154&quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Vent area equations ==&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Vent area equations ==&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l123&quot;&gt;Line 123:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 123:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Use in design and regulation ==&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Use in design and regulation ==&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Ural and Garzia (2008) name four explosion protection strategies: pressure containment, deflagration venting, deflagration suppression and deflagration isolation.&amp;lt;ref name=&quot;UG-17-154&quot; /&amp;gt; Venting suits cases where material toxicity and environmental contamination are not a concern and a safe discharge location exists, and it is then often &lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;the lowest&lt;/del&gt;-cost option.&amp;lt;ref name=&quot;UG-17-155&quot; /&amp;gt; NFPA 68, the VDI 3673 guideline and the European standard EN 14491 publish their correlations, so vendors, owners and authorities having jurisdiction can all check a vent size.&amp;lt;ref name=&quot;UG-17-155&quot; /&amp;gt; Suppression, by contrast, discharges no flame or fuel, so it suits indoor equipment and toxic materials.&amp;lt;ref name=&quot;Z02-3-417&quot;&amp;gt;Zalosh (2002), p. 3-417.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Ural and Garzia (2008) name four explosion protection strategies: pressure containment, deflagration venting, deflagration suppression and deflagration isolation.&amp;lt;ref name=&quot;UG-17-154&quot; /&amp;gt; Venting suits cases where material toxicity and environmental contamination are not a concern and a safe discharge location exists, and it is then often &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;a low&lt;/ins&gt;-cost &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;protection &lt;/ins&gt;option.&amp;lt;ref name=&quot;UG-17-155&quot; /&amp;gt; NFPA 68, the VDI 3673 guideline and the European standard EN 14491 publish their correlations, so vendors, owners and authorities having jurisdiction can all check a vent size.&amp;lt;ref name=&quot;UG-17-155&quot; /&amp;gt; Suppression, by contrast, discharges no flame or fuel, so it suits indoor equipment and toxic materials.&amp;lt;ref name=&quot;Z02-3-417&quot;&amp;gt;Zalosh (2002), p. 3-417.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Many chapters of the 2008 handbook point to NFPA 68 for specific equipment in the United States. Woodworking dust collectors may be protected by venting to NFPA 68, or by venting through a listed retention and quenching device or by suppression to NFPA 69.&amp;lt;ref name=&amp;quot;C-9-22&amp;quot;&amp;gt;Cholin (2008d), p. 9-22.&amp;lt;/ref&amp;gt; Coal dust collection systems should have explosion-relief vents sized to NFPA 68.&amp;lt;ref name=&amp;quot;D-7-7&amp;quot;&amp;gt;Dungan (2008b), p. 7-7.&amp;lt;/ref&amp;gt; Deflagration relief vents on ducts that carry explosible mixtures should lead by the most direct practical route outdoors.&amp;lt;ref name=&amp;quot;L-8-14&amp;quot;&amp;gt;Lataille (2008), p. 8-14.&amp;lt;/ref&amp;gt; Refrigeration machinery rooms with flammability Class 2 or 3 refrigerants should be outdoors or of damage-limiting construction to NFPA 68.&amp;lt;ref name=&amp;quot;F-8-124&amp;quot;&amp;gt;Febo (2008), p. 8-124.&amp;lt;/ref&amp;gt; In process pipes, vents placed to Chapter 9 of NFPA 68 limit pressure and flame speed, although the flame can still travel through the whole pipe.&amp;lt;ref name=&amp;quot;UG-17-158&amp;quot;&amp;gt;Ural and Garzia (2008), p. 17-158.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Many chapters of the 2008 handbook point to NFPA 68 for specific equipment in the United States. Woodworking dust collectors may be protected by venting to NFPA 68, or by venting through a listed retention and quenching device or by suppression to NFPA 69.&amp;lt;ref name=&amp;quot;C-9-22&amp;quot;&amp;gt;Cholin (2008d), p. 9-22.&amp;lt;/ref&amp;gt; Coal dust collection systems should have explosion-relief vents sized to NFPA 68.&amp;lt;ref name=&amp;quot;D-7-7&amp;quot;&amp;gt;Dungan (2008b), p. 7-7.&amp;lt;/ref&amp;gt; Deflagration relief vents on ducts that carry explosible mixtures should lead by the most direct practical route outdoors.&amp;lt;ref name=&amp;quot;L-8-14&amp;quot;&amp;gt;Lataille (2008), p. 8-14.&amp;lt;/ref&amp;gt; Refrigeration machinery rooms with flammability Class 2 or 3 refrigerants should be outdoors or of damage-limiting construction to NFPA 68.&amp;lt;ref name=&amp;quot;F-8-124&amp;quot;&amp;gt;Febo (2008), p. 8-124.&amp;lt;/ref&amp;gt; In process pipes, vents placed to Chapter 9 of NFPA 68 limit pressure and flame speed, although the flame can still travel through the whole pipe.&amp;lt;ref name=&amp;quot;UG-17-158&amp;quot;&amp;gt;Ural and Garzia (2008), p. 17-158.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;

&lt;!-- diff cache key firesb_pjbsiy42-wiki_:diff:1.41:old-3005:rev-4168:php=table --&gt;
&lt;/table&gt;</summary>
		<author><name>Jan</name></author>
	</entry>
	<entry>
		<id>https://fire-safety.academy/w/index.php?title=NFPA_68&amp;diff=3005&amp;oldid=prev</id>
		<title>Jan: New FSE wiki article: NFPA 68 (written by Claude Opus 5.5)</title>
		<link rel="alternate" type="text/html" href="https://fire-safety.academy/w/index.php?title=NFPA_68&amp;diff=3005&amp;oldid=prev"/>
		<updated>2026-11-07T21:05:25Z</updated>

		<summary type="html">&lt;p&gt;New FSE wiki article: NFPA 68 (written by Claude Opus 5.5)&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;&amp;#039;&amp;#039;&amp;#039;NFPA 68&amp;#039;&amp;#039;&amp;#039; is the US document of the [[NFPA|National Fire Protection Association]] (NFPA) on protecting enclosures against deflagrations by venting.&amp;lt;ref name=&amp;quot;S-18-79&amp;quot;&amp;gt;Schwab (2008b), p. 18-79.&amp;lt;/ref&amp;gt; Its 2007 edition is titled &amp;#039;&amp;#039;Standard on Explosion Protection by Deflagration Venting&amp;#039;&amp;#039;.&amp;lt;ref name=&amp;quot;S-18-79&amp;quot; /&amp;gt; A deflagration vent is an opening in an enclosure through which material expands and flows out, so that the pressure inside stays below a level the enclosure can withstand.&amp;lt;ref name=&amp;quot;S-18-83&amp;quot;&amp;gt;Schwab (2008b), p. 18-83.&amp;lt;/ref&amp;gt; The standard links the required vent area to the volume and strength of the enclosure and to the reactivity of the fuel, expressed as the [[deflagration index]] or the fundamental [[burning velocity]].&amp;lt;ref name=&amp;quot;S-18-84-85&amp;quot;&amp;gt;Schwab (2008b), pp. 18-84–18-85.&amp;lt;/ref&amp;gt; It also covers vent ducts, elongated enclosures and the fireball outside the vent.&amp;lt;ref name=&amp;quot;S-18-86-87&amp;quot;&amp;gt;Schwab (2008b), pp. 18-86–18-87.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
The first NFPA document on the subject dates from 1945; later versions appeared as guides before the 2007 edition was issued as a standard.&amp;lt;ref name=&amp;quot;S-18-79&amp;quot; /&amp;gt; Venting limits damage but does not prevent ignition.&amp;lt;ref name=&amp;quot;S-18-82&amp;quot;&amp;gt;Schwab (2008b), p. 18-82.&amp;lt;/ref&amp;gt; It is one of four explosion protection options, next to pressure containment, suppression and isolation.&amp;lt;ref name=&amp;quot;UG-17-154&amp;quot;&amp;gt;Ural and Garzia (2008), p. 17-154.&amp;lt;/ref&amp;gt; This article describes the 1998 and 2007 editions as summarised in the &amp;#039;&amp;#039;Fire Protection Handbook&amp;#039;&amp;#039; (2008) and the &amp;#039;&amp;#039;SFPE Handbook of Fire Protection Engineering&amp;#039;&amp;#039; (2002); later editions may differ.&lt;br /&gt;
&lt;br /&gt;
== History and editions ==&lt;br /&gt;
The first NFPA document on explosion venting was NFPA 68-T, &amp;#039;&amp;#039;Standard on Explosion Venting&amp;#039;&amp;#039;, tentatively adopted in 1945.&amp;lt;ref name=&amp;quot;S-18-79&amp;quot; /&amp;gt; A &amp;#039;&amp;#039;Guide for Explosion Venting&amp;#039;&amp;#039; followed in 1954 and brought together the best information then available, which Schwab (2008b) describes as sparse.&amp;lt;ref name=&amp;quot;S-18-79&amp;quot; /&amp;gt; Its data had no theoretical basis, and vent area was given as a vent ratio in square feet per cubic foot of enclosure volume.&amp;lt;ref name=&amp;quot;S-18-79&amp;quot; /&amp;gt; Enclosure strength was given little weight, although strong enclosures were known to need less vent area than weak ones.&amp;lt;ref name=&amp;quot;S-18-79&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Work at the US Bureau of Mines and larger test programmes in Great Britain, Germany and Switzerland in the late 1960s and early 1970s led to the 1974 edition, the &amp;#039;&amp;#039;Guide for Venting of Deflagrations&amp;#039;&amp;#039;.&amp;lt;ref name=&amp;quot;S-18-79&amp;quot; /&amp;gt; The procedures for enclosures of 1.5 psig (10.4 kPa) or stronger rest mainly on the work of Bartknecht and his associates.&amp;lt;ref name=&amp;quot;S6-148&amp;quot;&amp;gt;Schwab (2008c), p. 6-148.&amp;lt;/ref&amp;gt; Those for weaker structures are based on the work of Swift and Epstein.&amp;lt;ref name=&amp;quot;S6-148&amp;quot; /&amp;gt; The 1998 version still had the title &amp;#039;&amp;#039;Guide for Venting of Deflagrations&amp;#039;&amp;#039;.&amp;lt;ref name=&amp;quot;Z02-3-420&amp;quot;&amp;gt;Zalosh (2002), p. 3-420.&amp;lt;/ref&amp;gt; Its equation for dusts in high-strength enclosures was then the same as in the VDI 3673 guideline, and the technical committee had proposed a new dust equation for the 2002 edition.&amp;lt;ref name=&amp;quot;Z02-3-416&amp;quot;&amp;gt;Zalosh (2002), p. 3-416.&amp;lt;/ref&amp;gt; By 2007 the document had become a standard, titled &amp;#039;&amp;#039;Standard on Explosion Protection by Deflagration Venting&amp;#039;&amp;#039;.&amp;lt;ref name=&amp;quot;S-18-79&amp;quot; /&amp;gt; In that edition, data on the fundamental burning velocity can be used to set the venting parameter for more individual fuels than in earlier editions.&amp;lt;ref name=&amp;quot;S-18-85&amp;quot;&amp;gt;Schwab (2008b), p. 18-85.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== Scope and definitions ==&lt;br /&gt;
NFPA 68 clearly separates the terms deflagration, detonation and explosion.&amp;lt;ref name=&amp;quot;S-18-79&amp;quot; /&amp;gt; A deflagration is a combustion zone that spreads from the ignition point at less than the speed of sound in the unreacted medium.&amp;lt;ref name=&amp;quot;S-18-79&amp;quot; /&amp;gt; In a detonation it travels faster than sound.&amp;lt;ref name=&amp;quot;S-18-79&amp;quot; /&amp;gt; An explosion, in the narrow sense used by NFPA 68 and [[NFPA 69]], is &amp;quot;the bursting or rupture of an enclosure or a container due to the development of internal pressure from a deflagration&amp;quot;.&amp;lt;ref name=&amp;quot;UG-17-141&amp;quot;&amp;gt;Ural and Garzia (2008), p. 17-141.&amp;lt;/ref&amp;gt; The standard calls the relief of pressure from a combustion process slower than sound [[Explosion venting|explosion (deflagration) venting]], and it states that detonations cannot be vented.&amp;lt;ref name=&amp;quot;S-18-79&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
The fuel may be a flammable gas, a mist, a combustible dust, or a hybrid mixture of dust with gas or mist.&amp;lt;ref name=&amp;quot;S-18-80&amp;quot;&amp;gt;Schwab (2008b), p. 18-80.&amp;lt;/ref&amp;gt; Venting a [[dust explosion]] is therefore within its scope as well as venting a gas explosion.&amp;lt;ref name=&amp;quot;S-18-86&amp;quot;&amp;gt;Schwab (2008b), p. 18-86.&amp;lt;/ref&amp;gt; A deflagration needs a fuel concentration between the lower and upper combustible limits, enough oxidant (usually air) and an ignition source with enough energy.&amp;lt;ref name=&amp;quot;S-18-79&amp;quot; /&amp;gt; Solid particles smaller than 420 µm (0.017 in.), which pass a US No. 40 standard sieve, are classified as dusts.&amp;lt;ref name=&amp;quot;S-18-81&amp;quot;&amp;gt;Schwab (2008b), p. 18-81.&amp;lt;/ref&amp;gt; A flammable gas added to a dust cloud lowers the lower flammable limit and the ignition energy, even when gas and dust are each below their own limits.&amp;lt;ref name=&amp;quot;S-18-81&amp;quot; /&amp;gt; It also raises the effective dust deflagration index, and with it the vent area needed.&amp;lt;ref name=&amp;quot;S-18-81&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Deflagration venting limits damage to the protected enclosure; it is not a preventive measure.&amp;lt;ref name=&amp;quot;S-18-82&amp;quot; /&amp;gt; It presupposes that a combustible mixture will form in the enclosure and will be ignited, and it keeps the damage to a level chosen in advance.&amp;lt;ref name=&amp;quot;S-18-82&amp;quot; /&amp;gt; Some users accept a permanently deformed enclosure, while others accept only elastic deformation.&amp;lt;ref name=&amp;quot;S-18-82-83&amp;quot;&amp;gt;Schwab (2008b), pp. 18-82–18-83.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== Fuel parameters ==&lt;br /&gt;
Without venting, most fuels produce a maximum deflagration pressure, &amp;#039;&amp;#039;P&amp;#039;&amp;#039;&amp;lt;sub&amp;gt;max&amp;lt;/sub&amp;gt;, of 6 to 10 times the absolute pressure at the moment of ignition.&amp;lt;ref name=&amp;quot;S-18-80&amp;quot; /&amp;gt; Both this pressure and the maximum rate of pressure rise are measured in closed vessels at the optimum concentration, using a strong igniter.&amp;lt;ref name=&amp;quot;S-18-80&amp;quot; /&amp;gt; The basis of venting theory is the &amp;quot;cubic law&amp;quot;, which defines the deflagration index &amp;#039;&amp;#039;K&amp;#039;&amp;#039; as the maximum rate of pressure rise in a closed vessel multiplied by the cube root of the vessel volume:&amp;lt;ref name=&amp;quot;S-18-80&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;math display=&amp;quot;block&amp;quot;&amp;gt;K = \left(\frac{\mathrm{d}P}{\mathrm{d}t}\right)_{\max} V^{1/3}&amp;lt;/math&amp;gt;&lt;br /&gt;
&lt;br /&gt;
The index is written &amp;#039;&amp;#039;K&amp;#039;&amp;#039;&amp;lt;sub&amp;gt;G&amp;lt;/sub&amp;gt; for gases and &amp;#039;&amp;#039;K&amp;#039;&amp;#039;&amp;lt;sub&amp;gt;St&amp;lt;/sub&amp;gt; for dusts, and it is not a true constant, although older literature called it one.&amp;lt;ref name=&amp;quot;S-18-80&amp;quot; /&amp;gt; For dusts it is measured in roughly spherical calibrated vessels of at least 20 L to ASTM E1226, whereas the method for &amp;#039;&amp;#039;K&amp;#039;&amp;#039;&amp;lt;sub&amp;gt;G&amp;lt;/sub&amp;gt; has not been standardised.&amp;lt;ref name=&amp;quot;S-18-80&amp;quot; /&amp;gt; According to Ural and Garzia (2008), no standard test for &amp;#039;&amp;#039;K&amp;#039;&amp;#039;&amp;lt;sub&amp;gt;G&amp;lt;/sub&amp;gt; and burning velocity existed yet, but Annex C of NFPA 68 (2007) gives data and test guidance.&amp;lt;ref name=&amp;quot;UG-17-146-147&amp;quot;&amp;gt;Ural and Garzia (2008), pp. 17-146–17-147.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
The fundamental burning velocity, &amp;#039;&amp;#039;S&amp;#039;&amp;#039;&amp;lt;sub&amp;gt;u&amp;lt;/sub&amp;gt;, is the burning velocity of a laminar flame relative to the unburned gas under stated conditions of composition, temperature and pressure.&amp;lt;ref name=&amp;quot;S-18-81&amp;quot; /&amp;gt; Flame speed, measured against a fixed point, is at least the burning velocity times the expansion ratio of the gas.&amp;lt;ref name=&amp;quot;S-18-81&amp;quot; /&amp;gt; It rises with turbulence from obstructions, enclosure volume and ignition energy.&amp;lt;ref name=&amp;quot;S-18-81&amp;quot; /&amp;gt; The table gives values for common gases.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|+ Explosion parameters of selected gases in air&lt;br /&gt;
! Gas !! &amp;#039;&amp;#039;P&amp;#039;&amp;#039;&amp;lt;sub&amp;gt;max&amp;lt;/sub&amp;gt; (bar) !! &amp;#039;&amp;#039;K&amp;#039;&amp;#039;&amp;lt;sub&amp;gt;G&amp;lt;/sub&amp;gt; (bar·m/s) !! &amp;#039;&amp;#039;S&amp;#039;&amp;#039;&amp;lt;sub&amp;gt;u&amp;lt;/sub&amp;gt; (cm/s)&lt;br /&gt;
|-&lt;br /&gt;
| Methane || 7.1 || 55 || 40&lt;br /&gt;
|-&lt;br /&gt;
| Propane || 7.9 || 100 || 46&lt;br /&gt;
|-&lt;br /&gt;
| Butane (&amp;#039;&amp;#039;S&amp;#039;&amp;#039;&amp;lt;sub&amp;gt;u&amp;lt;/sub&amp;gt; for &amp;#039;&amp;#039;n&amp;#039;&amp;#039;-butane) || 8.0 || 92 || 45&lt;br /&gt;
|-&lt;br /&gt;
| Hydrogen || 6.8 || 550 || 312&lt;br /&gt;
|}&lt;br /&gt;
&amp;#039;&amp;#039;P&amp;#039;&amp;#039;&amp;lt;sub&amp;gt;max&amp;lt;/sub&amp;gt; and &amp;#039;&amp;#039;K&amp;#039;&amp;#039;&amp;lt;sub&amp;gt;G&amp;lt;/sub&amp;gt; were measured in a 5 L sphere with an ignition energy of 10 J; &amp;#039;&amp;#039;S&amp;#039;&amp;#039;&amp;lt;sub&amp;gt;u&amp;lt;/sub&amp;gt; is from a separate table.&amp;lt;ref name=&amp;quot;S-18-80&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;S-18-82&amp;quot; /&amp;gt; NFPA 68 (2007 edition, Table B.1, as reproduced in the handbook) places dusts in three hazard classes.&amp;lt;ref name=&amp;quot;S-18-80&amp;quot; /&amp;gt; Class St-1 covers &amp;#039;&amp;#039;K&amp;#039;&amp;#039;&amp;lt;sub&amp;gt;St&amp;lt;/sub&amp;gt; up to 200 bar·m/s, St-2 covers 201–300 bar·m/s and St-3 covers more than 300 bar·m/s, with &amp;#039;&amp;#039;P&amp;#039;&amp;#039;&amp;lt;sub&amp;gt;max&amp;lt;/sub&amp;gt; values of 10, 10 and 12 bar.&amp;lt;ref name=&amp;quot;S-18-80&amp;quot; /&amp;gt; Wheat flour with a particle size of 57 µm, for example, has a &amp;#039;&amp;#039;P&amp;#039;&amp;#039;&amp;lt;sub&amp;gt;max&amp;lt;/sub&amp;gt; of 8.3 bar and a &amp;#039;&amp;#039;K&amp;#039;&amp;#039;&amp;lt;sub&amp;gt;St&amp;lt;/sub&amp;gt; of 87 bar·m/s, which puts it in class St-1.&amp;lt;ref name=&amp;quot;S6-146&amp;quot;&amp;gt;Schwab (2008c), p. 6-146.&amp;lt;/ref&amp;gt; Irregular particles from a hammer mill give a faster pressure rise than spherical ones of similar size, so dust from the actual process should be tested.&amp;lt;ref name=&amp;quot;S-18-81&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== Enclosure strength and reduced pressure ==&lt;br /&gt;
The reduced pressure, &amp;#039;&amp;#039;P&amp;#039;&amp;#039;&amp;lt;sub&amp;gt;red&amp;lt;/sub&amp;gt;, is the maximum pressure developed in a vented enclosure during a vented deflagration.&amp;lt;ref name=&amp;quot;S-18-83&amp;quot; /&amp;gt; The rate of pressure rise is the most important design parameter: a fast rise leaves little time for venting and, other factors being equal, needs a larger vent.&amp;lt;ref name=&amp;quot;S-18-83&amp;quot; /&amp;gt; A larger vent gives a lower &amp;#039;&amp;#039;P&amp;#039;&amp;#039;&amp;lt;sub&amp;gt;red&amp;lt;/sub&amp;gt;, open vents work better than covered ones, and light closures respond faster than heavy ones.&amp;lt;ref name=&amp;quot;S-18-83&amp;quot; /&amp;gt; Weak structures leave little margin: an ordinary masonry wall of 20 cm (8 in.) brick or concrete block cannot withstand a pressure difference of more than 0.035 bar (0.5 psi).&amp;lt;ref name=&amp;quot;S-18-83&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Because the pressure rises quickly, the enclosure may feel it as a dynamic load rather than a static one.&amp;lt;ref name=&amp;quot;S-18-83&amp;quot; /&amp;gt; The ratio of maximum dynamic to static deflection under the same peak load is the dynamic load factor (DLF).&amp;lt;ref name=&amp;quot;S-18-84&amp;quot;&amp;gt;Schwab (2008b), p. 18-84.&amp;lt;/ref&amp;gt; NFPA 68 (2007), as summarised by Schwab (2008b), limits &amp;#039;&amp;#039;P&amp;#039;&amp;#039;&amp;lt;sub&amp;gt;red&amp;lt;/sub&amp;gt; to the static enclosure strength divided by this factor:&amp;lt;ref name=&amp;quot;S-18-84&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;math display=&amp;quot;block&amp;quot;&amp;gt;P_{\mathrm{red}} \le \frac{P_{\mathrm{es}}}{\mathrm{DLF}}, \qquad \mathrm{DLF} = \frac{X_m}{X_s}&amp;lt;/math&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Here &amp;#039;&amp;#039;P&amp;#039;&amp;#039;&amp;lt;sub&amp;gt;es&amp;lt;/sub&amp;gt; is the enclosure strength from static calculations for deformation or burst, and &amp;#039;&amp;#039;X&amp;#039;&amp;#039;&amp;lt;sub&amp;gt;m&amp;lt;/sub&amp;gt; and &amp;#039;&amp;#039;X&amp;#039;&amp;#039;&amp;lt;sub&amp;gt;s&amp;lt;/sub&amp;gt; are the dynamic and static deflections.&amp;lt;ref name=&amp;quot;S-18-84&amp;quot; /&amp;gt; Without a detailed structural response analysis, a conservative DLF of 1.5 is used, based on the weakest structural element, so that &amp;#039;&amp;#039;P&amp;#039;&amp;#039;&amp;lt;sub&amp;gt;red&amp;lt;/sub&amp;gt; reaches two-thirds of the enclosure strength.&amp;lt;ref name=&amp;quot;S-18-84&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
For pressure vessels built to the ASME &amp;#039;&amp;#039;Boiler and Pressure Vessel Code&amp;#039;&amp;#039;, the limit uses the maximum allowable working pressure.&amp;lt;ref name=&amp;quot;S-18-84&amp;quot; /&amp;gt; Where permanent deformation is accepted, &amp;#039;&amp;#039;P&amp;#039;&amp;#039;&amp;lt;sub&amp;gt;red&amp;lt;/sub&amp;gt; may reach two-thirds of that pressure times &amp;#039;&amp;#039;F&amp;#039;&amp;#039;&amp;lt;sub&amp;gt;u&amp;lt;/sub&amp;gt;, the ratio of ultimate to allowable stress.&amp;lt;ref name=&amp;quot;S-18-84&amp;quot; /&amp;gt; Where it is not, &amp;#039;&amp;#039;F&amp;#039;&amp;#039;&amp;lt;sub&amp;gt;y&amp;lt;/sub&amp;gt;, the ratio of yield to allowable stress, replaces &amp;#039;&amp;#039;F&amp;#039;&amp;#039;&amp;lt;sub&amp;gt;u&amp;lt;/sub&amp;gt;.&amp;lt;ref name=&amp;quot;S-18-84&amp;quot; /&amp;gt; For carbon steel or low-alloy stainless steel, &amp;#039;&amp;#039;F&amp;#039;&amp;#039;&amp;lt;sub&amp;gt;u&amp;lt;/sub&amp;gt; and &amp;#039;&amp;#039;F&amp;#039;&amp;#039;&amp;lt;sub&amp;gt;y&amp;lt;/sub&amp;gt; are about 3.5 and 1.75.&amp;lt;ref name=&amp;quot;UG-17-155&amp;quot;&amp;gt;Ural and Garzia (2008), p. 17-155.&amp;lt;/ref&amp;gt; A vessel with a maximum allowable working pressure of 1.0 bar may then reach a &amp;#039;&amp;#039;P&amp;#039;&amp;#039;&amp;lt;sub&amp;gt;red&amp;lt;/sub&amp;gt; of 2.33 bar if it may deform, or 1.17 bar if it may not. The ASME code accepts the NFPA 68 method for this purpose, so the allowable &amp;#039;&amp;#039;P&amp;#039;&amp;#039;&amp;lt;sub&amp;gt;red&amp;lt;/sub&amp;gt; can exceed the stamped working pressure.&amp;lt;ref name=&amp;quot;S-18-84&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;UG-17-155&amp;quot; /&amp;gt; For comparison, Ural and Garzia (2008) give 0.3 barg (5 psig) as a common deflagration load for venting or suppression and 10 barg (150 psig) for containment.&amp;lt;ref name=&amp;quot;UG-17-154&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== Vent area equations ==&lt;br /&gt;
NFPA 68 uses separate methods for low-strength and high-strength enclosures, with the boundary at a &amp;#039;&amp;#039;P&amp;#039;&amp;#039;&amp;lt;sub&amp;gt;red&amp;lt;/sub&amp;gt; of 0.1 bar (1.5 psi).&amp;lt;ref name=&amp;quot;S-18-84&amp;quot; /&amp;gt; Zalosh (2002) explains that the high-strength guidelines came mainly from European test programmes without low-pressure tests, while many US programmes used large, low-strength structures.&amp;lt;ref name=&amp;quot;Z02-3-415&amp;quot;&amp;gt;Zalosh (2002), p. 3-415.&amp;lt;/ref&amp;gt; All pressures in the equations are gauge pressures in bar unless stated otherwise.&amp;lt;ref name=&amp;quot;S-18-84&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
=== Low-strength enclosures ===&lt;br /&gt;
Enclosures that can withstand a &amp;#039;&amp;#039;P&amp;#039;&amp;#039;&amp;lt;sub&amp;gt;red&amp;lt;/sub&amp;gt; of no more than 0.1 bar are sized with an equation based on the internal surface area.&amp;lt;ref name=&amp;quot;S-18-84&amp;quot; /&amp;gt; The vent area grows with the surface area and with a venting parameter &amp;#039;&amp;#039;C&amp;#039;&amp;#039; for the fuel, and it falls with the square root of the allowed pressure.&amp;lt;ref name=&amp;quot;S-18-84&amp;quot; /&amp;gt; In the 2007 method, &amp;#039;&amp;#039;C&amp;#039;&amp;#039; follows from the fundamental burning velocity for fuels with &amp;#039;&amp;#039;S&amp;#039;&amp;#039;&amp;lt;sub&amp;gt;u&amp;lt;/sub&amp;gt; below 60 cm/s.&amp;lt;ref name=&amp;quot;S-18-84&amp;quot; /&amp;gt; Where several fuels may be present, the one with the highest burning velocity governs.&amp;lt;ref name=&amp;quot;S-18-85&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;math display=&amp;quot;block&amp;quot;&amp;gt;A_v = \frac{C\,A_s}{\sqrt{P_{\mathrm{red}}}}, \qquad C = 1.57\times10^{-5}\,S_u^2 + 1.57\times10^{-4}\,S_u + 0.0109&amp;lt;/math&amp;gt;&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
! Symbol !! Description !! Unit&lt;br /&gt;
|-&lt;br /&gt;
| &amp;#039;&amp;#039;A&amp;#039;&amp;#039;&amp;lt;sub&amp;gt;v&amp;lt;/sub&amp;gt; || Vent area || m²&lt;br /&gt;
|-&lt;br /&gt;
| &amp;#039;&amp;#039;C&amp;#039;&amp;#039; || Venting parameter || bar&amp;lt;sup&amp;gt;1/2&amp;lt;/sup&amp;gt;&lt;br /&gt;
|-&lt;br /&gt;
| &amp;#039;&amp;#039;A&amp;#039;&amp;#039;&amp;lt;sub&amp;gt;s&amp;lt;/sub&amp;gt; || Internal surface area of the enclosure || m²&lt;br /&gt;
|-&lt;br /&gt;
| &amp;#039;&amp;#039;P&amp;#039;&amp;#039;&amp;lt;sub&amp;gt;red&amp;lt;/sub&amp;gt; || Maximum pressure in the vented enclosure || bar (gauge)&lt;br /&gt;
|-&lt;br /&gt;
| &amp;#039;&amp;#039;S&amp;#039;&amp;#039;&amp;lt;sub&amp;gt;u&amp;lt;/sub&amp;gt; || Fundamental burning velocity, below 60 cm/s || cm/s&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;Worked example.&amp;#039;&amp;#039;&amp;#039; Zalosh (2002) sizes a vent for a 4 m × 4 m × 3 m room with a worst-case butane–air mixture.&amp;lt;ref name=&amp;quot;Z02-3-416&amp;quot; /&amp;gt; The damage threshold is 1.0 psig and the vent opens at 0.2 psig.&amp;lt;ref name=&amp;quot;Z02-3-416&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
The internal surface area is 2 × (4 × 4 + 4 × 3 + 4 × 3) = 80 m².&amp;lt;ref name=&amp;quot;Z02-3-416&amp;quot; /&amp;gt; With &amp;#039;&amp;#039;S&amp;#039;&amp;#039;&amp;lt;sub&amp;gt;u&amp;lt;/sub&amp;gt; = 45 cm/s for &amp;#039;&amp;#039;n&amp;#039;&amp;#039;-butane, the equation gives &amp;#039;&amp;#039;C&amp;#039;&amp;#039; = 0.0498 bar&amp;lt;sup&amp;gt;1/2&amp;lt;/sup&amp;gt;.&amp;lt;ref name=&amp;quot;S-18-82&amp;quot; /&amp;gt; With &amp;#039;&amp;#039;P&amp;#039;&amp;#039;&amp;lt;sub&amp;gt;red&amp;lt;/sub&amp;gt; = 1.0 psi = 0.0689 bar, the vent area is 0.0498 × 80 / √0.0689 ≈ 15.2 m², about one-fifth of the internal surface area. The 1998 method that Zalosh (2002) used, with &amp;#039;&amp;#039;C&amp;#039;&amp;#039; = 0.17 psi&amp;lt;sup&amp;gt;1/2&amp;lt;/sup&amp;gt; for gases with a burning velocity below 60 cm/s, gave 13.6 m² for the same room.&amp;lt;ref name=&amp;quot;Z02-3-416&amp;quot; /&amp;gt; The 2007 equation therefore asks for about 11 % more vent area in this case.&lt;br /&gt;
&lt;br /&gt;
=== High-strength enclosures ===&lt;br /&gt;
Compact enclosures have a length-to-diameter ratio (&amp;#039;&amp;#039;L&amp;#039;&amp;#039;/&amp;#039;&amp;#039;D&amp;#039;&amp;#039;) of 2 or less.&amp;lt;ref name=&amp;quot;S-18-83&amp;quot; /&amp;gt; For gas deflagrations in them, the 2007 method uses &amp;#039;&amp;#039;K&amp;#039;&amp;#039;&amp;lt;sub&amp;gt;G&amp;lt;/sub&amp;gt;, &amp;#039;&amp;#039;P&amp;#039;&amp;#039;&amp;lt;sub&amp;gt;red&amp;lt;/sub&amp;gt;, the vent opening pressure &amp;#039;&amp;#039;P&amp;#039;&amp;#039;&amp;lt;sub&amp;gt;stat&amp;lt;/sub&amp;gt; and the volume:&amp;lt;ref name=&amp;quot;S-18-85&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;math display=&amp;quot;block&amp;quot;&amp;gt;A_v = \left[0.127\log_{10}K_G - 0.0567\right]P_{\mathrm{red}}^{-0.582}\,V^{2/3} + 0.175\,P_{\mathrm{red}}^{-0.572}\left(P_{\mathrm{stat}} - 0.1\right)V^{2/3}&amp;lt;/math&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Its limits are &amp;#039;&amp;#039;K&amp;#039;&amp;#039;&amp;lt;sub&amp;gt;G&amp;lt;/sub&amp;gt; up to 550 bar·m/s, &amp;#039;&amp;#039;P&amp;#039;&amp;#039;&amp;lt;sub&amp;gt;stat&amp;lt;/sub&amp;gt; up to 0.5 bar and a volume up to 1,000 m³.&amp;lt;ref name=&amp;quot;S-18-85&amp;quot; /&amp;gt; &amp;#039;&amp;#039;P&amp;#039;&amp;#039;&amp;lt;sub&amp;gt;red&amp;lt;/sub&amp;gt; is printed as 2 bar and at least 0.5 bar above &amp;#039;&amp;#039;P&amp;#039;&amp;#039;&amp;lt;sub&amp;gt;stat&amp;lt;/sub&amp;gt;.&amp;lt;ref name=&amp;quot;S-18-85&amp;quot; /&amp;gt; Extra terms enlarge the area for &amp;#039;&amp;#039;L&amp;#039;&amp;#039;/&amp;#039;&amp;#039;D&amp;#039;&amp;#039; between 2 and 5 and for panels heavier than a threshold mass.&amp;lt;ref name=&amp;quot;S-18-85&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
For dusts and hybrid mixtures, the equation applies to enclosures stronger than 0.1 bar with &amp;#039;&amp;#039;L&amp;#039;&amp;#039;/&amp;#039;&amp;#039;D&amp;#039;&amp;#039; up to 2.&amp;lt;ref name=&amp;quot;S-18-86&amp;quot; /&amp;gt; The initial pressure is 1 bar absolute (±0.2 bar):&amp;lt;ref name=&amp;quot;S-18-86&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;math display=&amp;quot;block&amp;quot;&amp;gt;A_{vo} = 1\times10^{-4}\left(1 + 1.54\,P_{\mathrm{stat}}^{4/3}\right)K_{St}\,V^{3/4}\sqrt{\frac{P_{\max}}{P_{\mathrm{red}}} - 1}&amp;lt;/math&amp;gt;&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
! Symbol !! Description !! Unit&lt;br /&gt;
|-&lt;br /&gt;
| &amp;#039;&amp;#039;A&amp;#039;&amp;#039;&amp;lt;sub&amp;gt;vo&amp;lt;/sub&amp;gt; || Vent area || m²&lt;br /&gt;
|-&lt;br /&gt;
| &amp;#039;&amp;#039;P&amp;#039;&amp;#039;&amp;lt;sub&amp;gt;stat&amp;lt;/sub&amp;gt; || Nominal static burst pressure of the vent, up to 0.75 || bar&lt;br /&gt;
|-&lt;br /&gt;
| &amp;#039;&amp;#039;K&amp;#039;&amp;#039;&amp;lt;sub&amp;gt;St&amp;lt;/sub&amp;gt; || Dust deflagration index, 10 to 800 || bar·m/s&lt;br /&gt;
|-&lt;br /&gt;
| &amp;#039;&amp;#039;V&amp;#039;&amp;#039; || Enclosure volume, 0.1 to 10,000 || m³&lt;br /&gt;
|-&lt;br /&gt;
| &amp;#039;&amp;#039;P&amp;#039;&amp;#039;&amp;lt;sub&amp;gt;max&amp;lt;/sub&amp;gt; || Maximum deflagration pressure, 5 to 12 || bar&lt;br /&gt;
|-&lt;br /&gt;
| &amp;#039;&amp;#039;P&amp;#039;&amp;#039;&amp;lt;sub&amp;gt;red&amp;lt;/sub&amp;gt; || Reduced pressure after the vent opens || bar&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
For &amp;#039;&amp;#039;L&amp;#039;&amp;#039;/&amp;#039;&amp;#039;D&amp;#039;&amp;#039; above 2 and up to 6, the area is multiplied by 1 + 0.6 (&amp;#039;&amp;#039;L&amp;#039;&amp;#039;/&amp;#039;&amp;#039;D&amp;#039;&amp;#039; − 2)&amp;lt;sup&amp;gt;0.75&amp;lt;/sup&amp;gt; exp(−0.95 &amp;#039;&amp;#039;P&amp;#039;&amp;#039;&amp;lt;sub&amp;gt;red&amp;lt;/sub&amp;gt;&amp;lt;sup&amp;gt;2&amp;lt;/sup&amp;gt;).&amp;lt;ref name=&amp;quot;S-18-86&amp;quot; /&amp;gt; For top-fed bins, hoppers and silos, &amp;#039;&amp;#039;L&amp;#039;&amp;#039;/&amp;#039;&amp;#039;D&amp;#039;&amp;#039; can be increased to 8.&amp;lt;ref name=&amp;quot;S-18-86&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;Worked example.&amp;#039;&amp;#039;&amp;#039; A 50 m³ compact enclosure (&amp;#039;&amp;#039;L&amp;#039;&amp;#039;/&amp;#039;&amp;#039;D&amp;#039;&amp;#039; ≤ 2) handles wheat flour with &amp;#039;&amp;#039;P&amp;#039;&amp;#039;&amp;lt;sub&amp;gt;max&amp;lt;/sub&amp;gt; = 8.3 bar and &amp;#039;&amp;#039;K&amp;#039;&amp;#039;&amp;lt;sub&amp;gt;St&amp;lt;/sub&amp;gt; = 87 bar·m/s.&amp;lt;ref name=&amp;quot;S6-146&amp;quot; /&amp;gt; Its weakest element withstands 0.75 bar, so with a DLF of 1.5 the design value is &amp;#039;&amp;#039;P&amp;#039;&amp;#039;&amp;lt;sub&amp;gt;red&amp;lt;/sub&amp;gt; = 0.50 bar.&amp;lt;ref name=&amp;quot;S-18-84&amp;quot; /&amp;gt; With a vent of &amp;#039;&amp;#039;P&amp;#039;&amp;#039;&amp;lt;sub&amp;gt;stat&amp;lt;/sub&amp;gt; = 0.1 bar, the three factors are 1.072, 50&amp;lt;sup&amp;gt;0.75&amp;lt;/sup&amp;gt; = 18.8 and √(8.3/0.50 − 1) = 3.95. The vent area is 10&amp;lt;sup&amp;gt;−4&amp;lt;/sup&amp;gt; × 1.072 × 87 × 18.8 × 3.95 = 0.692 m², rounded up to 0.70 m². A vent cover that opens at 0.2 bar instead raises the area to 0.77 m², and an &amp;#039;&amp;#039;L&amp;#039;&amp;#039;/&amp;#039;&amp;#039;D&amp;#039;&amp;#039; of 4 with the 0.1 bar vent raises it to about 1.25 m².&lt;br /&gt;
&lt;br /&gt;
As a check, Zalosh (2002) sized vents for a 400 m³ electrostatic precipitator in a power plant firing bituminous coal (&amp;#039;&amp;#039;K&amp;#039;&amp;#039;&amp;lt;sub&amp;gt;St&amp;lt;/sub&amp;gt; = 59 bar·m/s, &amp;#039;&amp;#039;P&amp;#039;&amp;#039;&amp;lt;sub&amp;gt;max&amp;lt;/sub&amp;gt; = 9.1 bar).&amp;lt;ref name=&amp;quot;Z02-3-416-417&amp;quot;&amp;gt;Zalosh (2002), pp. 3-416–3-417.&amp;lt;/ref&amp;gt; With &amp;#039;&amp;#039;P&amp;#039;&amp;#039;&amp;lt;sub&amp;gt;red&amp;lt;/sub&amp;gt; = 1.2 bar and &amp;#039;&amp;#039;P&amp;#039;&amp;#039;&amp;lt;sub&amp;gt;stat&amp;lt;/sub&amp;gt; = 0.4 bar, he found 1.96 m² with the equation then proposed for the 2002 edition.&amp;lt;ref name=&amp;quot;Z02-3-416-417&amp;quot; /&amp;gt; The 2007 equation above gives 1.97 m² for the same inputs. Zalosh used the damage threshold of 1.2 bar directly as &amp;#039;&amp;#039;P&amp;#039;&amp;#039;&amp;lt;sub&amp;gt;red&amp;lt;/sub&amp;gt;; with the 2007 load factor of 1.5, &amp;#039;&amp;#039;P&amp;#039;&amp;#039;&amp;lt;sub&amp;gt;red&amp;lt;/sub&amp;gt; would be 0.8 bar and the area 2.47 m².&lt;br /&gt;
&lt;br /&gt;
=== Vent ducts, panel mass and elevated pressure ===&lt;br /&gt;
A duct that leads the vented gases to a safe outside location resists the outflow and raises the pressure in the enclosure, so the vent area must be increased.&amp;lt;ref name=&amp;quot;S-18-83&amp;quot; /&amp;gt; The correction is found by trial and error from the resistance coefficient of the duct.&amp;lt;ref name=&amp;quot;S-18-83&amp;quot; /&amp;gt; Reaction forces on the enclosure and the place where the fireball leaves the duct must also be considered.&amp;lt;ref name=&amp;quot;S-18-86&amp;quot; /&amp;gt; NFPA 68 intends ducts to be as short and straight as possible and vent closures to be as light as possible; insulated panels add mass and can raise the achieved &amp;#039;&amp;#039;P&amp;#039;&amp;#039;&amp;lt;sub&amp;gt;red&amp;lt;/sub&amp;gt;.&amp;lt;ref name=&amp;quot;S-18-86&amp;quot; /&amp;gt; Where a dust cloud is above 0.2 bar before ignition, vents are allowed only under extra conditions.&amp;lt;ref name=&amp;quot;S-18-86&amp;quot; /&amp;gt; These include an initial pressure below 4.0 bar and a panel mass below 40 kg/m².&amp;lt;ref name=&amp;quot;S-18-86&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== Effects outside the vent ==&lt;br /&gt;
Flames and pressure waves that leave the vent must not ignite nearby combustibles or injure people.&amp;lt;ref name=&amp;quot;S-18-83&amp;quot; /&amp;gt; For a vented dust or hybrid deflagration, the handbook estimates the axial reach of the fireball &amp;#039;&amp;#039;D&amp;#039;&amp;#039; (m) from the volume &amp;#039;&amp;#039;V&amp;#039;&amp;#039; (m³) and the number of evenly distributed vents &amp;#039;&amp;#039;n&amp;#039;&amp;#039;:&amp;lt;ref name=&amp;quot;S-18-86&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;math display=&amp;quot;block&amp;quot;&amp;gt;D = K\left(\frac{V}{n}\right)^{1/3}&amp;lt;/math&amp;gt;&lt;br /&gt;
&lt;br /&gt;
The flame length factor &amp;#039;&amp;#039;K&amp;#039;&amp;#039; is 10 for metal dusts and 8 for chemical and agricultural dusts, and the distance is limited to 60 m (200 ft).&amp;lt;ref name=&amp;quot;S-18-86-87&amp;quot;&amp;gt;Schwab (2008b), pp. 18-86–18-87.&amp;lt;/ref&amp;gt; For gas and vapour deflagrations the equation is &amp;#039;&amp;#039;D&amp;#039;&amp;#039; = 3.1 (&amp;#039;&amp;#039;V&amp;#039;&amp;#039;/&amp;#039;&amp;#039;n&amp;#039;&amp;#039;)&amp;lt;sup&amp;gt;0.402&amp;lt;/sup&amp;gt;, with a hazard zone to the sides of half that distance.&amp;lt;ref name=&amp;quot;S-18-87&amp;quot;&amp;gt;Schwab (2008b), p. 18-87.&amp;lt;/ref&amp;gt; The maximum external pressure is estimated as 0.2 &amp;#039;&amp;#039;P&amp;#039;&amp;#039;&amp;lt;sub&amp;gt;red&amp;lt;/sub&amp;gt; &amp;#039;&amp;#039;A&amp;#039;&amp;#039;&amp;lt;sub&amp;gt;v&amp;lt;/sub&amp;gt;&amp;lt;sup&amp;gt;0.1&amp;lt;/sup&amp;gt; &amp;#039;&amp;#039;V&amp;#039;&amp;#039;&amp;lt;sup&amp;gt;0.18&amp;lt;/sup&amp;gt;, and at a distance &amp;#039;&amp;#039;r&amp;#039;&amp;#039; of at least 0.2&amp;#039;&amp;#039;D&amp;#039;&amp;#039; from the vent it falls in proportion to 0.2&amp;#039;&amp;#039;D&amp;#039;&amp;#039;/&amp;#039;&amp;#039;r&amp;#039;&amp;#039;.&amp;lt;ref name=&amp;quot;S-18-87&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
For the wheat flour enclosure with one vent, the fireball reaches 8 × 50&amp;lt;sup&amp;gt;1/3&amp;lt;/sup&amp;gt; = 29.5 m, rounded up to 30 m. The maximum external pressure is 0.2 × 0.50 × 0.692&amp;lt;sup&amp;gt;0.1&amp;lt;/sup&amp;gt; × 50&amp;lt;sup&amp;gt;0.18&amp;lt;/sup&amp;gt; ≈ 0.2 bar, falling to about 0.04 bar at 30 m from the vent. Gagnon (2008) warns that explosion venting louvres must not be placed where an explosion relief blast could injure an operator or a passer-by.&amp;lt;ref name=&amp;quot;G-16-130&amp;quot;&amp;gt;Gagnon (2008), p. 16-130.&amp;lt;/ref&amp;gt; Iqbal and Salley (2004) add that gases released through an explosion vent, even a door or a window, can produce turbulence and a second pressure peak, citing Harris (1983).&amp;lt;ref name=&amp;quot;IS-15-5&amp;quot;&amp;gt;Iqbal and Salley (2004), p. 15-5.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Equipment may also be vented inside a building through a flame-arresting and particulate retention device.&amp;lt;ref name=&amp;quot;S-18-87&amp;quot; /&amp;gt; The pressure rise in an unvented building is then 1.47 times the ambient pressure times the ratio of equipment volume to free building volume.&amp;lt;ref name=&amp;quot;S-18-87&amp;quot; /&amp;gt; A 10 m³ collector in a building with 5,000 m³ of free volume would raise the pressure by about 3 mbar.&lt;br /&gt;
&lt;br /&gt;
== Use in design and regulation ==&lt;br /&gt;
Ural and Garzia (2008) name four explosion protection strategies: pressure containment, deflagration venting, deflagration suppression and deflagration isolation.&amp;lt;ref name=&amp;quot;UG-17-154&amp;quot; /&amp;gt; Venting suits cases where material toxicity and environmental contamination are not a concern and a safe discharge location exists, and it is then often the lowest-cost option.&amp;lt;ref name=&amp;quot;UG-17-155&amp;quot; /&amp;gt; NFPA 68, the VDI 3673 guideline and the European standard EN 14491 publish their correlations, so vendors, owners and authorities having jurisdiction can all check a vent size.&amp;lt;ref name=&amp;quot;UG-17-155&amp;quot; /&amp;gt; Suppression, by contrast, discharges no flame or fuel, so it suits indoor equipment and toxic materials.&amp;lt;ref name=&amp;quot;Z02-3-417&amp;quot;&amp;gt;Zalosh (2002), p. 3-417.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Many chapters of the 2008 handbook point to NFPA 68 for specific equipment in the United States. Woodworking dust collectors may be protected by venting to NFPA 68, or by venting through a listed retention and quenching device or by suppression to NFPA 69.&amp;lt;ref name=&amp;quot;C-9-22&amp;quot;&amp;gt;Cholin (2008d), p. 9-22.&amp;lt;/ref&amp;gt; Coal dust collection systems should have explosion-relief vents sized to NFPA 68.&amp;lt;ref name=&amp;quot;D-7-7&amp;quot;&amp;gt;Dungan (2008b), p. 7-7.&amp;lt;/ref&amp;gt; Deflagration relief vents on ducts that carry explosible mixtures should lead by the most direct practical route outdoors.&amp;lt;ref name=&amp;quot;L-8-14&amp;quot;&amp;gt;Lataille (2008), p. 8-14.&amp;lt;/ref&amp;gt; Refrigeration machinery rooms with flammability Class 2 or 3 refrigerants should be outdoors or of damage-limiting construction to NFPA 68.&amp;lt;ref name=&amp;quot;F-8-124&amp;quot;&amp;gt;Febo (2008), p. 8-124.&amp;lt;/ref&amp;gt; In process pipes, vents placed to Chapter 9 of NFPA 68 limit pressure and flame speed, although the flame can still travel through the whole pipe.&amp;lt;ref name=&amp;quot;UG-17-158&amp;quot;&amp;gt;Ural and Garzia (2008), p. 17-158.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Buildings can be designed so that some elements dislocate at low pressure while others stay in place, but Lemoff (2008) notes that this suits industrial structures rather than most ordinary buildings.&amp;lt;ref name=&amp;quot;Le-6-175&amp;quot;&amp;gt;Lemoff (2008), p. 6-175.&amp;lt;/ref&amp;gt; For grain elevators, Maness and Sargent (2008) call doors, windows, multiple explosion-relief panels and light-gauge coverings on steel structures a practical approach to an acceptable design.&amp;lt;ref name=&amp;quot;MS-9-99-100&amp;quot;&amp;gt;Maness and Sargent (2008), pp. 9-99–9-100.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== Limitations ==&lt;br /&gt;
The vent equations rest on tests in fairly large enclosures with near worst-case mixtures, and many of the gas data were enveloped rather than correlated.&amp;lt;ref name=&amp;quot;Z02-3-415&amp;quot; /&amp;gt; The recommended &amp;#039;&amp;#039;C&amp;#039;&amp;#039; values of the 1998 method are the highest values inferred from 18 test references, covering volumes from 0.18 to 82.3 m³.&amp;lt;ref name=&amp;quot;Z02-3-416&amp;quot; /&amp;gt; For propane, the most likely value was about one-third of the recommended one, but a very turbulent case such as a hammer mill could exceed it.&amp;lt;ref name=&amp;quot;Z02-3-416&amp;quot; /&amp;gt; The guidelines do not account for application-specific turbulence, equipment obstructions or partial filling of the enclosure.&amp;lt;ref name=&amp;quot;Z02-3-416&amp;quot; /&amp;gt; Since the vent area is proportional to &amp;#039;&amp;#039;K&amp;#039;&amp;#039;&amp;lt;sub&amp;gt;St&amp;lt;/sub&amp;gt;, which varies widely among coals and other materials, it should be based on samples from the site.&amp;lt;ref name=&amp;quot;Z02-3-417&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Pressure builds quickly: in an enclosure of 1 m radius with a burning velocity of 45 cm/s, it reaches 0.14 bar (2 psig) in about 0.2 s.&amp;lt;ref name=&amp;quot;Z08-2-99&amp;quot;&amp;gt;Zalosh (2008), p. 2-99.&amp;lt;/ref&amp;gt; At that damage threshold, venting would have to act within 0.2 s of ignition.&amp;lt;ref name=&amp;quot;Z08-2-99&amp;quot; /&amp;gt; Venting relieves pressure but does nothing to stop the continued burning of the fuel.&amp;lt;ref name=&amp;quot;G-16-130&amp;quot; /&amp;gt; It may be inappropriate where toxic or noxious materials are involved or where vents cannot discharge to a safe location.&amp;lt;ref name=&amp;quot;UG-17-155&amp;quot; /&amp;gt; Finally, the handbook refers readers to the NFPA catalogue for current editions, and the equations here describe US practice of about 1998 to 2007.&amp;lt;ref name=&amp;quot;S-18-87&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== See also ==&lt;br /&gt;
* [[Deflagration]]&lt;br /&gt;
* [[Explosion suppression system]]&lt;br /&gt;
* [[Explosion isolation]]&lt;br /&gt;
* [[Dust collector]]&lt;br /&gt;
* [[Pressure relief device]]&lt;br /&gt;
&lt;br /&gt;
== Notes ==&lt;br /&gt;
&amp;lt;references /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== References ==&lt;br /&gt;
* Cholin, J. M. (2008d). Woodworking facilities and processes. In A. E. Cote, C. C. Grant, J. R. Hall Jr., &amp;amp; R. E. Solomon (Eds.), &amp;#039;&amp;#039;Fire protection handbook&amp;#039;&amp;#039; (20th ed., pp. 9-3–9-25). National Fire Protection Association.&lt;br /&gt;
* Dungan, K. W. (2008b). Storage and handling of solid fuels. In A. E. Cote, C. C. Grant, J. R. Hall Jr., &amp;amp; R. E. Solomon (Eds.), &amp;#039;&amp;#039;Fire protection handbook&amp;#039;&amp;#039; (20th ed., pp. 7-3–7-13). National Fire Protection Association.&lt;br /&gt;
* Febo, H. L., Jr. (2008). Refrigeration systems. In A. E. Cote, C. C. Grant, J. R. Hall Jr., &amp;amp; R. E. Solomon (Eds.), &amp;#039;&amp;#039;Fire protection handbook&amp;#039;&amp;#039; (20th ed., pp. 8-117–8-125). National Fire Protection Association.&lt;br /&gt;
* Gagnon, R. M. (2008). Ultra-High-Speed water spray systems. In A. E. Cote, C. C. Grant, J. R. Hall Jr., &amp;amp; R. E. Solomon (Eds.), &amp;#039;&amp;#039;Fire protection handbook&amp;#039;&amp;#039; (20th ed., pp. 16-109–16-133). National Fire Protection Association.&lt;br /&gt;
* Iqbal, N., &amp;amp; Salley, M. H. (2004). &amp;#039;&amp;#039;Fire Dynamics Tools (FDTs): Quantitative fire hazard analysis methods for the U.S. Nuclear Regulatory Commission Fire Protection Inspection Program&amp;#039;&amp;#039; (NUREG-1805). U.S. Nuclear Regulatory Commission, Office of Nuclear Reactor Regulation.&lt;br /&gt;
* Lataille, J. I. (2008). Air-Moving equipment. In A. E. Cote, C. C. Grant, J. R. Hall Jr., &amp;amp; R. E. Solomon (Eds.), &amp;#039;&amp;#039;Fire protection handbook&amp;#039;&amp;#039; (20th ed., pp. 8-3–8-15). National Fire Protection Association.&lt;br /&gt;
* Lemoff, T. C. (2008). Gases. In A. E. Cote, C. C. Grant, J. R. Hall Jr., &amp;amp; R. E. Solomon (Eds.), &amp;#039;&amp;#039;Fire protection handbook&amp;#039;&amp;#039; (20th ed., pp. 6-165–6-186). National Fire Protection Association.&lt;br /&gt;
* Maness, J. E., &amp;amp; Sargent, L. M. (2008). Storage and handling of grain mill products. In A. E. Cote, C. C. Grant, J. R. Hall Jr., &amp;amp; R. E. Solomon (Eds.), &amp;#039;&amp;#039;Fire protection handbook&amp;#039;&amp;#039; (20th ed., pp. 9-85–9-103). National Fire Protection Association.&lt;br /&gt;
* Schwab, R. F. (2008b). Deflagration (explosion) venting. In A. E. Cote, C. C. Grant, J. R. Hall Jr., &amp;amp; R. E. Solomon (Eds.), &amp;#039;&amp;#039;Fire protection handbook&amp;#039;&amp;#039; (20th ed., pp. 18-79–18-88). National Fire Protection Association.&lt;br /&gt;
* Schwab, R. F. (2008c). Dusts. In A. E. Cote, C. C. Grant, J. R. Hall Jr., &amp;amp; R. E. Solomon (Eds.), &amp;#039;&amp;#039;Fire protection handbook&amp;#039;&amp;#039; (20th ed., pp. 6-141–6-152). National Fire Protection Association.&lt;br /&gt;
* Ural, E. A., &amp;amp; Garzia, H. W. (2008). Explosion prevention and protection. In A. E. Cote, C. C. Grant, J. R. Hall Jr., &amp;amp; R. E. Solomon (Eds.), &amp;#039;&amp;#039;Fire protection handbook&amp;#039;&amp;#039; (20th ed., pp. 17-141–17-165). National Fire Protection Association.&lt;br /&gt;
* Zalosh, R. (2002). Explosion protection. In P. J. DiNenno, D. Drysdale, C. L. Beyler, W. D. Walton, R. L. P. Custer, J. R. Hall Jr., &amp;amp; J. M. Watts Jr. (Eds.), &amp;#039;&amp;#039;SFPE handbook of fire protection engineering&amp;#039;&amp;#039; (3rd ed., pp. 3-402–3-421). National Fire Protection Association; Society of Fire Protection Engineers.&lt;br /&gt;
* Zalosh, R. (2008). Explosions. In A. E. Cote, C. C. Grant, J. R. Hall Jr., &amp;amp; R. E. Solomon (Eds.), &amp;#039;&amp;#039;Fire protection handbook&amp;#039;&amp;#039; (20th ed., pp. 2-93–2-106). National Fire Protection Association.&lt;br /&gt;
&lt;br /&gt;
[[Category:Explosions &amp;amp; Industrial Fires]]&lt;/div&gt;</summary>
		<author><name>Jan</name></author>
	</entry>
</feed>