<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://fire-safety.academy/w/index.php?action=history&amp;feed=atom&amp;title=Mass_timber</id>
	<title>Mass timber - Revision history</title>
	<link rel="self" type="application/atom+xml" href="https://fire-safety.academy/w/index.php?action=history&amp;feed=atom&amp;title=Mass_timber"/>
	<link rel="alternate" type="text/html" href="https://fire-safety.academy/w/index.php?title=Mass_timber&amp;action=history"/>
	<updated>2026-11-24T11:30:50Z</updated>
	<subtitle>Revision history for this page on the wiki</subtitle>
	<generator>MediaWiki 1.43.11</generator>
	<entry>
		<id>https://fire-safety.academy/w/index.php?title=Mass_timber&amp;diff=9681&amp;oldid=prev</id>
		<title>Mark: New FSE wiki article: Mass timber (written by GPT-6)</title>
		<link rel="alternate" type="text/html" href="https://fire-safety.academy/w/index.php?title=Mass_timber&amp;diff=9681&amp;oldid=prev"/>
		<updated>2026-11-23T19:12:36Z</updated>

		<summary type="html">&lt;p&gt;New FSE wiki article: Mass timber (written by GPT-6)&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;&amp;#039;&amp;#039;&amp;#039;Mass timber&amp;#039;&amp;#039;&amp;#039; is structural wood used in large load-bearing sections or panels. Examples include glued-laminated timber (glulam) beams and cross-laminated timber (CLT) panels. A building may use a few deep beams and columns where a lightweight timber frame would use many slender members. The difference matters in fire because the dimensions of the wood remaining beneath the heated surface influence how much load it can carry.&amp;lt;ref name=&amp;quot;wood&amp;quot;&amp;gt;Willse (2008), §19.1, pp. 19-8–19-9.&amp;lt;/ref&amp;gt;&amp;lt;ref name=&amp;quot;clt&amp;quot;&amp;gt;Australian Building Codes Board (2020), Data Sheet B1, pp. 7, 23, citing McGregor (2013).&amp;lt;/ref&amp;gt;&amp;lt;ref name=&amp;quot;core&amp;quot;&amp;gt;White (2002), ch. 4-11, pp. 4-265–4-268.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Exposed timber can contribute energy to a compartment fire at the same time as its cooler core continues to support a load. These are two distinct questions for [[Structural fire engineering|structural fire engineering]]. One concerns how the fire develops in a room. The other concerns the strength of an individual beam, column or connection as the exposure continues.&amp;lt;ref name=&amp;quot;clt&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;woodload&amp;quot;&amp;gt;Van Rossum (2027), §4.4.&amp;lt;/ref&amp;gt;&amp;lt;ref name=&amp;quot;core&amp;quot; /&amp;gt;&lt;br /&gt;
[[File:fse-mass-timber-v1.jpg|thumb|upright=1.5|alt=Illustrative studio view of a glulam beam with stacked wood lamellae visible on the cut end and long side.|AI-generated illustration of a glulam beam. The cut end and side show the layers forming one structural member. Based on Willse (2008), §19.1, pp. 19-8–19-9.]]&lt;br /&gt;
&lt;br /&gt;
== From the exposed face to the core ==&lt;br /&gt;
Heating breaks down the wood at the surface. Combustible gases escape, and a layer of char forms. The char has little load-bearing capacity and slows heating of the wood behind it. The timber just inside the char front can already be hot enough to have lost some strength. Oxidation at a solid surface can also continue without visible flames as [[Smouldering|smouldering]]. An assessment of [[Timber in fire|timber in fire]] therefore considers both the lost section and the properties of the wood that remains.&amp;lt;ref name=&amp;quot;char&amp;quot;&amp;gt;White (2002), ch. 4-11, pp. 4-260–4-261.&amp;lt;/ref&amp;gt;&amp;lt;ref name=&amp;quot;core&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;smoulder&amp;quot;&amp;gt;Ohlemiller (2002), ch. 2-9, pp. 2-200–2-201.&amp;lt;/ref&amp;gt;&lt;br /&gt;
[[File:fse-mass-timber-v2.svg|thumb|upright=1.5|alt=Cross-section from left to right showing char, heated uncharred wood and a cooler core.|Part of the uncharred wood near the char front can already have reduced strength. Based on White (2002), ch. 4-11, pp. 4-265–4-268.]]&lt;br /&gt;
&lt;br /&gt;
== A one-face charring estimate ==&lt;br /&gt;
For a broad face exposed to a standard furnace fire, a constant [[Charring rate|charring rate]] gives a first estimate of the depth converted to char. White reports a commonly used approximation of 0.6 mm/min across the grain for the ASTM E119 standard exposure. Taking 30 minutes as an illustrative exposure gives an estimated char depth of 18 mm on that face.&amp;lt;ref name=&amp;quot;char&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;math display=&amp;quot;block&amp;quot;&amp;gt;d=\beta t=(0.6\ \mathrm{mm/min})(30\ \mathrm{min})=18\ \mathrm{mm}&amp;lt;/math&amp;gt;&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
! Symbol !! Meaning !! Unit&lt;br /&gt;
|-&lt;br /&gt;
| &amp;lt;math&amp;gt;d&amp;lt;/math&amp;gt; || Depth measured from the original face to the char front || mm&lt;br /&gt;
|-&lt;br /&gt;
| &amp;lt;math&amp;gt;\beta&amp;lt;/math&amp;gt; || Assumed linear charring rate || mm/min&lt;br /&gt;
|-&lt;br /&gt;
| &amp;lt;math&amp;gt;t&amp;lt;/math&amp;gt; || Duration of the assumed exposure || min&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
The example assumes that the same face is exposed throughout. Corners, multiple exposed faces and changes in the fire exposure affect the remaining section. The [[Reduced cross-section method|reduced cross-section method]] can make a further allowance for heated wood beneath the char. The [[Fire resistance|fire resistance]] of the assembly also depends on the load and the capacity of its connections.&amp;lt;ref name=&amp;quot;char&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;core&amp;quot; /&amp;gt;&lt;br /&gt;
[[File:fse-mass-timber-v3.svg|thumb|upright=1.5|alt=Line graph rises from 0 mm initially to 18 mm after 30 minutes using an assumed rate of 0.6 mm per minute.|A constant rate of 0.6 mm/min gives an estimated char depth of 18 mm after 30 min of the assumed standard exposure. Based on White (2002), ch. 4-11, pp. 4-260–4-261.]]&lt;br /&gt;
&lt;br /&gt;
== Exposed surfaces and fire load ==&lt;br /&gt;
Furniture and contents form part of the variable [[Fire load|fire load]]. Exposed structural wood can also contribute to the permanent fire load. The distinction matters when using tabulated fuel loads for the contents of a room. The Australian verification data sheets identify the combustion of construction elements, including timber panels, as a possible contribution during a compartment fire.&amp;lt;ref name=&amp;quot;clt&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;woodload&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== Members, panels and the building ==&lt;br /&gt;
The fire assessment of a [[High-rise building|high-rise building]] can involve both the load path through timber connections and the behaviour of extensive exposed surfaces. New Zealand’s C/VM2 (2025) illustrates the distinction in its interior-linings scenario. It lists specified structural timber members among the surface-finish exceptions, but excludes exposed panels on the underside of a floor or ceiling from that particular exception.&amp;lt;ref name=&amp;quot;core&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;nzwood&amp;quot;&amp;gt;Ministry of Business, Innovation and Employment (2025), §4.7, p. 50.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== See also ==&lt;br /&gt;
* [[Cavity barrier]]&lt;br /&gt;
* [[Standard fire curve]]&lt;br /&gt;
* [[Fire resistance criteria]]&lt;br /&gt;
&lt;br /&gt;
== Notes ==&lt;br /&gt;
&amp;lt;references /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== References ==&lt;br /&gt;
* Australian Building Codes Board. (2020). &amp;#039;&amp;#039;[https://watermark.abcb.gov.au/sites/default/files/resources/2020/Handbook_annex_Fire_Safety_Verification_Method_Data_Sheets.pdf Fire safety verification method: Data sheets]&amp;#039;&amp;#039;.&lt;br /&gt;
* Ministry of Business, Innovation and Employment. (2025). &amp;#039;&amp;#039;[https://www.building.govt.nz/assets/Uploads/building-code-compliance/c-protection-from-fire/asvm/c-protection-from-fire-vm2-second-edition.pdf C protection from fire: Verification method C/VM2]&amp;#039;&amp;#039; (2nd ed.). New Zealand Government.&lt;br /&gt;
* Ohlemiller, T. J. (2002). Smoldering combustion. In P. J. DiNenno (Ed.), &amp;#039;&amp;#039;SFPE handbook of fire protection engineering&amp;#039;&amp;#039; (3rd ed.). National Fire Protection Association.&lt;br /&gt;
* Van Rossum, E. (2027). &amp;#039;&amp;#039;Introduction to Fire Safety Engineering&amp;#039;&amp;#039;. Fire Safety Academy.&lt;br /&gt;
* White, R. H. (2002). Analytical methods for determining fire resistance of timber members. In P. J. DiNenno (Ed.), &amp;#039;&amp;#039;SFPE handbook of fire protection engineering&amp;#039;&amp;#039; (3rd ed.). National Fire Protection Association.&lt;br /&gt;
* Willse, P. J. G. (2008). Types of building construction. In A. E. Cote (Ed.), &amp;#039;&amp;#039;Fire protection handbook&amp;#039;&amp;#039; (20th ed.). National Fire Protection Association.&lt;br /&gt;
&lt;br /&gt;
[[Category:Structural Fire Engineering]]&lt;/div&gt;</summary>
		<author><name>Mark</name></author>
	</entry>
</feed>