<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://fire-safety.academy/w/index.php?action=history&amp;feed=atom&amp;title=Live_fire_training</id>
	<title>Live fire training - Revision history</title>
	<link rel="self" type="application/atom+xml" href="https://fire-safety.academy/w/index.php?action=history&amp;feed=atom&amp;title=Live_fire_training"/>
	<link rel="alternate" type="text/html" href="https://fire-safety.academy/w/index.php?title=Live_fire_training&amp;action=history"/>
	<updated>2026-11-21T21:45:49Z</updated>
	<subtitle>Revision history for this page on the wiki</subtitle>
	<generator>MediaWiki 1.43.11</generator>
	<entry>
		<id>https://fire-safety.academy/w/index.php?title=Live_fire_training&amp;diff=9231&amp;oldid=prev</id>
		<title>Peter: Wiki review: corrected 1 error: american-spelling (Claude Opus 5.5)</title>
		<link rel="alternate" type="text/html" href="https://fire-safety.academy/w/index.php?title=Live_fire_training&amp;diff=9231&amp;oldid=prev"/>
		<updated>2026-11-15T23:37:15Z</updated>

		<summary type="html">&lt;p&gt;Wiki review: corrected 1 error: american-spelling (Claude Opus 5.5)&lt;/p&gt;
&lt;table style=&quot;background-color: #fff; color: #202122;&quot; data-mw=&quot;interface&quot;&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;tr class=&quot;diff-title&quot; lang=&quot;en&quot;&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;← Older revision&lt;/td&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;Revision as of 00:37, 16 November 2026&lt;/td&gt;
				&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l45&quot;&gt;Line 45:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 45:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Safety rules and NFPA 1403 ==&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Safety rules and NFPA 1403 ==&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Laughlin (2008) reads the training injuries and deaths of the previous 25 years as a warning. Instructors can forget that a realistic scenario can have disastrous results when safety is not the paramount consideration.&amp;lt;ref name=&quot;Laughlin-12-172&quot; /&amp;gt; Such training deaths and injuries form part of the wider record of [[Firefighter injuries and fatalities|firefighter injuries and fatalities]]. NFPA 1403 was developed after numerous training deaths, especially those of two fire fighters at Boulder in 1982 in an abandoned wood-frame building.&amp;lt;ref name=&quot;Laughlin-12-172&quot; /&amp;gt; There, rapid fire spread across a combustible low-density &lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;fiberboard &lt;/del&gt;ceiling, an inadequate water supply, inadequate exits and a general lack of planning contributed to the deaths.&amp;lt;ref name=&quot;Laughlin-12-172&quot; /&amp;gt; During its development, NFPA 1403 drew approximately 1,000 comments at the Report on Comments stage in 1985, and the first edition followed in 1986.&amp;lt;ref name=&quot;Loflin-12-109&quot;&amp;gt;Loflin (2008), p. 12-109.&amp;lt;/ref&amp;gt;&amp;lt;ref name=&quot;Laughlin-12-172&quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Laughlin (2008) reads the training injuries and deaths of the previous 25 years as a warning. Instructors can forget that a realistic scenario can have disastrous results when safety is not the paramount consideration.&amp;lt;ref name=&quot;Laughlin-12-172&quot; /&amp;gt; Such training deaths and injuries form part of the wider record of [[Firefighter injuries and fatalities|firefighter injuries and fatalities]]. NFPA 1403 was developed after numerous training deaths, especially those of two fire fighters at Boulder in 1982 in an abandoned wood-frame building.&amp;lt;ref name=&quot;Laughlin-12-172&quot; /&amp;gt; There, rapid fire spread across a combustible low-density &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;fibreboard &lt;/ins&gt;ceiling, an inadequate water supply, inadequate exits and a general lack of planning contributed to the deaths.&amp;lt;ref name=&quot;Laughlin-12-172&quot; /&amp;gt; During its development, NFPA 1403 drew approximately 1,000 comments at the Report on Comments stage in 1985, and the first edition followed in 1986.&amp;lt;ref name=&quot;Loflin-12-109&quot;&amp;gt;Loflin (2008), p. 12-109.&amp;lt;/ref&amp;gt;&amp;lt;ref name=&quot;Laughlin-12-172&quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The guidance was not always followed. In 1987 three fire fighters died in an exercise in an old frame house in Milford, Michigan, where multiple fires had been set to create a realistic scenario. The scenario did not comply with NFPA 1403: planning was lacking, escape paths were insufficient, the water supply was inadequate and large amounts of accelerants were used. Safety was not a sufficient priority to prevent an unanticipated flashover while fire fighters were still inside.&amp;lt;ref name=&amp;quot;Laughlin-12-172&amp;quot; /&amp;gt; In a Florida incident in 2002, a fire was set in a vacant concrete-block dwelling to accompany search and rescue training. The two trainees had no ready water supply and there were insufficient escape paths.&amp;lt;ref name=&amp;quot;Laughlin-12-173&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The guidance was not always followed. In 1987 three fire fighters died in an exercise in an old frame house in Milford, Michigan, where multiple fires had been set to create a realistic scenario. The scenario did not comply with NFPA 1403: planning was lacking, escape paths were insufficient, the water supply was inadequate and large amounts of accelerants were used. Safety was not a sufficient priority to prevent an unanticipated flashover while fire fighters were still inside.&amp;lt;ref name=&amp;quot;Laughlin-12-172&amp;quot; /&amp;gt; In a Florida incident in 2002, a fire was set in a vacant concrete-block dwelling to accompany search and rescue training. The two trainees had no ready water supply and there were insufficient escape paths.&amp;lt;ref name=&amp;quot;Laughlin-12-173&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;

&lt;!-- diff cache key firesb_pjbsiy42-wiki_:diff:1.41:old-8976:rev-9231:php=table --&gt;
&lt;/table&gt;</summary>
		<author><name>Peter</name></author>
	</entry>
	<entry>
		<id>https://fire-safety.academy/w/index.php?title=Live_fire_training&amp;diff=8976&amp;oldid=prev</id>
		<title>Linda: Add SVG figures fse-live-fire-training-v1.svg, fse-live-fire-training-v2.svg, fse-live-fire-training-v3.svg, fse-live-fire-training-v4.svg (list-8 visual plan)</title>
		<link rel="alternate" type="text/html" href="https://fire-safety.academy/w/index.php?title=Live_fire_training&amp;diff=8976&amp;oldid=prev"/>
		<updated>2026-11-14T17:28:45Z</updated>

		<summary type="html">&lt;p&gt;Add SVG figures fse-live-fire-training-v1.svg, fse-live-fire-training-v2.svg, fse-live-fire-training-v3.svg, fse-live-fire-training-v4.svg (list-8 visual plan)&lt;/p&gt;
&lt;table style=&quot;background-color: #fff; color: #202122;&quot; data-mw=&quot;interface&quot;&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;tr class=&quot;diff-title&quot; lang=&quot;en&quot;&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;← Older revision&lt;/td&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;Revision as of 18:28, 14 November 2026&lt;/td&gt;
				&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l14&quot;&gt;Line 14:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 14:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The sources give slightly different thresholds. Custer (2008) states that flashover is triggered when the upper gas layer reaches approximately 600 °C and the radiant heat flux on unignited materials is approximately 20 kW/m².&amp;lt;ref name=&amp;quot;Custer-2-56&amp;quot; /&amp;gt; Van Rossum (2027) links a heat flux of about 20 kW/m² to a hot smoke layer above 500 °C, a flux at which many materials pyrolyse rapidly. He also names a lower-layer temperature above 300 to 350 °C, at which many combustibles on the floor become hot enough to ignite spontaneously.&amp;lt;ref name=&amp;quot;VR-4.7&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The sources give slightly different thresholds. Custer (2008) states that flashover is triggered when the upper gas layer reaches approximately 600 °C and the radiant heat flux on unignited materials is approximately 20 kW/m².&amp;lt;ref name=&amp;quot;Custer-2-56&amp;quot; /&amp;gt; Van Rossum (2027) links a heat flux of about 20 kW/m² to a hot smoke layer above 500 °C, a flux at which many materials pyrolyse rapidly. He also names a lower-layer temperature above 300 to 350 °C, at which many combustibles on the floor become hot enough to ignite spontaneously.&amp;lt;ref name=&amp;quot;VR-4.7&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-deleted&quot;&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;[[File:fse-live-fire-training-v3.svg|thumb|upright=1.5|alt=Two-layer room fire with upper layer described as above 500 °C or about 600 °C, with 20 kW/m2 radiation to the floor and layer burning at the interface|Conditions associated with flashover in a room fire, and the location of layer burning.]]&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Other phenomena arise when the fire is short of air. Gottuk and Lattimer (2002) describe [[Rollover|layer burning]] as the ignition of fuel-rich upper-layer gases at the interface between the hot upper layer and the cooler lower layer. It can occur only under underventilated burning.&amp;lt;ref name=&amp;quot;GL-2-55&amp;quot;&amp;gt;Gottuk and Lattimer (2002), p. 2-55.&amp;lt;/ref&amp;gt; A [[Backdraft|backdraft]] is the explosive ignition of accumulated pyrolysis gases when fresh air suddenly enters, for example when a door is opened. Van Rossum (2027) calls it a dangerous phenomenon for the fire service.&amp;lt;ref name=&amp;quot;VR-4.9&amp;quot;&amp;gt;Van Rossum (2027), §4.9.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Other phenomena arise when the fire is short of air. Gottuk and Lattimer (2002) describe [[Rollover|layer burning]] as the ignition of fuel-rich upper-layer gases at the interface between the hot upper layer and the cooler lower layer. It can occur only under underventilated burning.&amp;lt;ref name=&amp;quot;GL-2-55&amp;quot;&amp;gt;Gottuk and Lattimer (2002), p. 2-55.&amp;lt;/ref&amp;gt; A [[Backdraft|backdraft]] is the explosive ignition of accumulated pyrolysis gases when fresh air suddenly enters, for example when a door is opened. Van Rossum (2027) calls it a dangerous phenomenon for the fire service.&amp;lt;ref name=&amp;quot;VR-4.9&amp;quot;&amp;gt;Van Rossum (2027), §4.9.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l21&quot;&gt;Line 21:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 22:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Training environments ==&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Training environments ==&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;NFPA 1403 has chapters covering acquired structures; gas-fired and non-gas-fired buildings at training centres; exterior props; and exterior Class B (flammable liquid) fires.&amp;lt;ref name=&amp;quot;Laughlin-12-173&amp;quot; /&amp;gt; Laughlin (2008) singles out the chapter on acquired structures as especially important, because the most preventable injuries and fatalities occur in such buildings.&amp;lt;ref name=&amp;quot;Laughlin-12-173&amp;quot; /&amp;gt; Corbett (2008) makes a related point. In most typical training school structures, the hazards of collapse, hidden fire and highly combustible interior finish are absent. There have been serious accidents during live fire training in abandoned buildings where these hazards were present.&amp;lt;ref name=&amp;quot;Corbett-12-130&amp;quot;&amp;gt;Corbett (2008), p. 12-130.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;NFPA 1403 has chapters covering acquired structures; gas-fired and non-gas-fired buildings at training centres; exterior props; and exterior Class B (flammable liquid) fires.&amp;lt;ref name=&amp;quot;Laughlin-12-173&amp;quot; /&amp;gt; Laughlin (2008) singles out the chapter on acquired structures as especially important, because the most preventable injuries and fatalities occur in such buildings.&amp;lt;ref name=&amp;quot;Laughlin-12-173&amp;quot; /&amp;gt; Corbett (2008) makes a related point. In most typical training school structures, the hazards of collapse, hidden fire and highly combustible interior finish are absent. There have been serious accidents during live fire training in abandoned buildings where these hazards were present.&amp;lt;ref name=&amp;quot;Corbett-12-130&amp;quot;&amp;gt;Corbett (2008), p. 12-130.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-deleted&quot;&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;[[File:fse-live-fire-training-v1.svg|thumb|upright=1.5|alt=Four panels showing acquired structure, training centre burn building, exterior gas prop and exterior flammable liquid fire|Training settings addressed by NFPA 1403, as described in 2008.]]&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;At a training centre, the first design choice for a burn building is the fuel. The two main options are Class A fuels and gas-fired props that burn liquefied petroleum (LP) gas or natural gas.&amp;lt;ref name=&amp;quot;AcombLeBoeuf-12-247&amp;quot; /&amp;gt; Class A fires are fires in ordinary combustible materials such as wood, cloth and paper, and Class B fires are fires in flammable and combustible liquids.&amp;lt;ref name=&amp;quot;Conroy-17-71&amp;quot;&amp;gt;Conroy (2008), p. 17-71.&amp;lt;/ref&amp;gt; Acomb and LeBoeuf (2008) note that the benefits of one are the drawbacks of the other, so some centres build burn buildings that can use both.&amp;lt;ref name=&amp;quot;AcombLeBoeuf-12-247&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;At a training centre, the first design choice for a burn building is the fuel. The two main options are Class A fuels and gas-fired props that burn liquefied petroleum (LP) gas or natural gas.&amp;lt;ref name=&amp;quot;AcombLeBoeuf-12-247&amp;quot; /&amp;gt; Class A fires are fires in ordinary combustible materials such as wood, cloth and paper, and Class B fires are fires in flammable and combustible liquids.&amp;lt;ref name=&amp;quot;Conroy-17-71&amp;quot;&amp;gt;Conroy (2008), p. 17-71.&amp;lt;/ref&amp;gt; Acomb and LeBoeuf (2008) note that the benefits of one are the drawbacks of the other, so some centres build burn buildings that can use both.&amp;lt;ref name=&amp;quot;AcombLeBoeuf-12-247&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l30&quot;&gt;Line 30:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 32:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Burn building design ==&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Burn building design ==&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Acomb and LeBoeuf (2008) describe the burn building as usually the first training structure provided at a training centre.&amp;lt;ref name=&amp;quot;AcombLeBoeuf-12-247&amp;quot; /&amp;gt; It can deteriorate quickly if it is not designed correctly, and there are three main causes of damage. The first is heat, which can reach 2000 °F (1093 °C) where flames impinge directly, as on ceilings above training fires. The second is thermal shock when heated surfaces are sprayed with cold water. The third is abuse inherent in training, such as hose streams and impacts from tools and gear.&amp;lt;ref name=&amp;quot;AcombLeBoeuf-12-247&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Acomb and LeBoeuf (2008) describe the burn building as usually the first training structure provided at a training centre.&amp;lt;ref name=&amp;quot;AcombLeBoeuf-12-247&amp;quot; /&amp;gt; It can deteriorate quickly if it is not designed correctly, and there are three main causes of damage. The first is heat, which can reach 2000 °F (1093 °C) where flames impinge directly, as on ceilings above training fires. The second is thermal shock when heated surfaces are sprayed with cold water. The third is abuse inherent in training, such as hose streams and impacts from tools and gear.&amp;lt;ref name=&amp;quot;AcombLeBoeuf-12-247&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-deleted&quot;&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;[[File:fse-live-fire-training-v2.svg|thumb|upright=1.5|alt=Cross-section of a burn room showing flame impingement on a lined ceiling, a hose stream causing thermal shock and tool impacts|Heat, thermal shock and physical abuse damage burn buildings; thermal linings protect the structure.]]&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;No building material is immune to these conditions. Masonry cracks and gradually deteriorates, steel warps and corrodes, and concrete cracks and spalls.&amp;lt;ref name=&amp;quot;AcombLeBoeuf-12-247&amp;quot; /&amp;gt; The structural elements are therefore protected with thermal linings. For ceilings these are mostly proprietary products that differ in materials and installation, so they should be judged on initial and long-term cost, verifiable durability and insulating capability, and references.&amp;lt;ref name=&amp;quot;AcombLeBoeuf-12-247&amp;quot; /&amp;gt; Steel is not an insulator and tends to warp, and refractory (calcium aluminate) concrete should not be used for structural components because of its record of severe damage.&amp;lt;ref name=&amp;quot;AcombLeBoeuf-12-247&amp;quot; /&amp;gt; The two most common types of burn building are combinations of concrete and masonry and pre-engineered steel buildings.&amp;lt;ref name=&amp;quot;AcombLeBoeuf-12-247-248&amp;quot;&amp;gt;Acomb and LeBoeuf (2008), pp. 12-247–12-248.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;No building material is immune to these conditions. Masonry cracks and gradually deteriorates, steel warps and corrodes, and concrete cracks and spalls.&amp;lt;ref name=&amp;quot;AcombLeBoeuf-12-247&amp;quot; /&amp;gt; The structural elements are therefore protected with thermal linings. For ceilings these are mostly proprietary products that differ in materials and installation, so they should be judged on initial and long-term cost, verifiable durability and insulating capability, and references.&amp;lt;ref name=&amp;quot;AcombLeBoeuf-12-247&amp;quot; /&amp;gt; Steel is not an insulator and tends to warp, and refractory (calcium aluminate) concrete should not be used for structural components because of its record of severe damage.&amp;lt;ref name=&amp;quot;AcombLeBoeuf-12-247&amp;quot; /&amp;gt; The two most common types of burn building are combinations of concrete and masonry and pre-engineered steel buildings.&amp;lt;ref name=&amp;quot;AcombLeBoeuf-12-247-248&amp;quot;&amp;gt;Acomb and LeBoeuf (2008), pp. 12-247–12-248.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l45&quot;&gt;Line 45:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 48:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The guidance was not always followed. In 1987 three fire fighters died in an exercise in an old frame house in Milford, Michigan, where multiple fires had been set to create a realistic scenario. The scenario did not comply with NFPA 1403: planning was lacking, escape paths were insufficient, the water supply was inadequate and large amounts of accelerants were used. Safety was not a sufficient priority to prevent an unanticipated flashover while fire fighters were still inside.&amp;lt;ref name=&amp;quot;Laughlin-12-172&amp;quot; /&amp;gt; In a Florida incident in 2002, a fire was set in a vacant concrete-block dwelling to accompany search and rescue training. The two trainees had no ready water supply and there were insufficient escape paths.&amp;lt;ref name=&amp;quot;Laughlin-12-173&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The guidance was not always followed. In 1987 three fire fighters died in an exercise in an old frame house in Milford, Michigan, where multiple fires had been set to create a realistic scenario. The scenario did not comply with NFPA 1403: planning was lacking, escape paths were insufficient, the water supply was inadequate and large amounts of accelerants were used. Safety was not a sufficient priority to prevent an unanticipated flashover while fire fighters were still inside.&amp;lt;ref name=&amp;quot;Laughlin-12-172&amp;quot; /&amp;gt; In a Florida incident in 2002, a fire was set in a vacant concrete-block dwelling to accompany search and rescue training. The two trainees had no ready water supply and there were insufficient escape paths.&amp;lt;ref name=&amp;quot;Laughlin-12-173&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-deleted&quot;&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;[[File:fse-live-fire-training-v4.svg|thumb|upright=1.5|alt=Timeline from 1982 to 2004 of US live fire training incidents and the development of NFPA 1403|US live fire training incidents and NFPA 1403, 1982–2004.]]&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The exercise had designated [[Incident safety officer|safety officers]] and a rapid intervention team, but the fuel load contributed to a flashover only 3 minutes later.&amp;lt;ref name=&amp;quot;Laughlin-12-173&amp;quot; /&amp;gt; Four instructors inside the building as interior safety officers escaped, but the lieutenant and the fire fighter in the exercise died of smoke inhalation and thermal injuries.&amp;lt;ref name=&amp;quot;Laughlin-12-173&amp;quot; /&amp;gt; After a 19-year-old trainee died in New York in 2001, the officer supervising the exercise was convicted of criminally negligent homicide. The state then offered two programmes on live fire training safety, both referring to NFPA 1403.&amp;lt;ref name=&amp;quot;Laughlin-12-173&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The exercise had designated [[Incident safety officer|safety officers]] and a rapid intervention team, but the fuel load contributed to a flashover only 3 minutes later.&amp;lt;ref name=&amp;quot;Laughlin-12-173&amp;quot; /&amp;gt; Four instructors inside the building as interior safety officers escaped, but the lieutenant and the fire fighter in the exercise died of smoke inhalation and thermal injuries.&amp;lt;ref name=&amp;quot;Laughlin-12-173&amp;quot; /&amp;gt; After a 19-year-old trainee died in New York in 2001, the officer supervising the exercise was convicted of criminally negligent homicide. The state then offered two programmes on live fire training safety, both referring to NFPA 1403.&amp;lt;ref name=&amp;quot;Laughlin-12-173&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;

&lt;!-- diff cache key firesb_pjbsiy42-wiki_:diff:1.41:old-5274:rev-8976:php=table --&gt;
&lt;/table&gt;</summary>
		<author><name>Linda</name></author>
	</entry>
	<entry>
		<id>https://fire-safety.academy/w/index.php?title=Live_fire_training&amp;diff=5274&amp;oldid=prev</id>
		<title>Linda: Add watermarked Fire Safety Academy illustration at the location specified in the visual plan</title>
		<link rel="alternate" type="text/html" href="https://fire-safety.academy/w/index.php?title=Live_fire_training&amp;diff=5274&amp;oldid=prev"/>
		<updated>2026-11-08T08:35:15Z</updated>

		<summary type="html">&lt;p&gt;Add watermarked Fire Safety Academy illustration at the location specified in the visual plan&lt;/p&gt;
&lt;table style=&quot;background-color: #fff; color: #202122;&quot; data-mw=&quot;interface&quot;&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;tr class=&quot;diff-title&quot; lang=&quot;en&quot;&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;← Older revision&lt;/td&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;Revision as of 09:35, 8 November 2026&lt;/td&gt;
				&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l34&quot;&gt;Line 34:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 34:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Details serve both training and safety. Possible features include various roof pitches and ventilation cutouts, durable doors and shutters that tolerate heat while keeping in smoke, drainage scuppers, forced-entry doors, standpipes and temperature monitoring systems.&amp;lt;ref name=&amp;quot;AcombLeBoeuf-12-248&amp;quot;&amp;gt;Acomb and LeBoeuf (2008), p. 12-248.&amp;lt;/ref&amp;gt; The building is best accessible from all sides and lockable where the grounds are not fenced.&amp;lt;ref name=&amp;quot;AcombLeBoeuf-12-248&amp;quot; /&amp;gt; A burn building combined with a training tower saves site space, whereas separate structures allow live fire training and tower drills to run at the same time.&amp;lt;ref name=&amp;quot;AcombLeBoeuf-12-249&amp;quot;&amp;gt;Acomb and LeBoeuf (2008), p. 12-249.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Details serve both training and safety. Possible features include various roof pitches and ventilation cutouts, durable doors and shutters that tolerate heat while keeping in smoke, drainage scuppers, forced-entry doors, standpipes and temperature monitoring systems.&amp;lt;ref name=&amp;quot;AcombLeBoeuf-12-248&amp;quot;&amp;gt;Acomb and LeBoeuf (2008), p. 12-248.&amp;lt;/ref&amp;gt; The building is best accessible from all sides and lockable where the grounds are not fenced.&amp;lt;ref name=&amp;quot;AcombLeBoeuf-12-248&amp;quot; /&amp;gt; A burn building combined with a training tower saves site space, whereas separate structures allow live fire training and tower drills to run at the same time.&amp;lt;ref name=&amp;quot;AcombLeBoeuf-12-249&amp;quot;&amp;gt;Acomb and LeBoeuf (2008), p. 12-249.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-deleted&quot;&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-deleted&quot;&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;[[File:fse-live-fire-training-v5.jpg|thumb|upright=1.5|alt=Concrete burn building at a fire training centre with smoke from a window and a hose crew at the entrance|A burn building at a fire service training centre during a controlled training fire.]]&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Experience in designing schools or fire stations does not provide the expertise needed for live fire training structures. Architects and engineers without training centre experience should therefore team with specialist consultants.&amp;lt;ref name=&amp;quot;AcombLeBoeuf-12-241&amp;quot;&amp;gt;Acomb and LeBoeuf (2008), p. 12-241.&amp;lt;/ref&amp;gt; The authors treat training centres together with [[Fire station design|fire station design]], since needs assessment, master planning, site selection and design follow the same process for both.&amp;lt;ref name=&amp;quot;AcombLeBoeuf-12-251&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Experience in designing schools or fire stations does not provide the expertise needed for live fire training structures. Architects and engineers without training centre experience should therefore team with specialist consultants.&amp;lt;ref name=&amp;quot;AcombLeBoeuf-12-241&amp;quot;&amp;gt;Acomb and LeBoeuf (2008), p. 12-241.&amp;lt;/ref&amp;gt; The authors treat training centres together with [[Fire station design|fire station design]], since needs assessment, master planning, site selection and design follow the same process for both.&amp;lt;ref name=&amp;quot;AcombLeBoeuf-12-251&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;

&lt;!-- diff cache key firesb_pjbsiy42-wiki_:diff:1.41:old-4304:rev-5274:php=table --&gt;
&lt;/table&gt;</summary>
		<author><name>Linda</name></author>
	</entry>
	<entry>
		<id>https://fire-safety.academy/w/index.php?title=Live_fire_training&amp;diff=4304&amp;oldid=prev</id>
		<title>Lisa: FSE wiki: fact-check corrections (written by Claude Opus 5.5)</title>
		<link rel="alternate" type="text/html" href="https://fire-safety.academy/w/index.php?title=Live_fire_training&amp;diff=4304&amp;oldid=prev"/>
		<updated>2026-11-08T02:59:16Z</updated>

		<summary type="html">&lt;p&gt;FSE wiki: fact-check corrections (written by Claude Opus 5.5)&lt;/p&gt;
&lt;table style=&quot;background-color: #fff; color: #202122;&quot; data-mw=&quot;interface&quot;&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;tr class=&quot;diff-title&quot; lang=&quot;en&quot;&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;← Older revision&lt;/td&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;Revision as of 03:59, 8 November 2026&lt;/td&gt;
				&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l11&quot;&gt;Line 11:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 11:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Fire behaviour in training ==&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Fire behaviour in training ==&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;A training fire inside a structure is a compartment fire, &lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;and trainees &lt;/del&gt;must learn to recognise how it develops. NFPA 1403 calls for students in acquired structures to have prior training so that they understand the safety issues and can recognise normal and abnormal fire behaviour.&amp;lt;ref name=&quot;Laughlin-12-173&quot; /&amp;gt; A key transition is [[Flashover|flashover]], in which surfaces exposed to thermal radiation reach their ignition temperature more or less simultaneously and fire spreads rapidly through the whole space.&amp;lt;ref name=&quot;Janssens-2-61&quot;&amp;gt;Janssens (2008), p. 2-61.&amp;lt;/ref&amp;gt; Before flashover a fire is local and fuel-controlled; after it the whole room is burning and the fire is usually ventilation-controlled.&amp;lt;ref name=&quot;VR-4.7&quot;&amp;gt;Van Rossum (2027), §4.7.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;A training fire inside a structure is a compartment fire&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;.&amp;lt;ref name=&quot;Custer-2-56&quot;&amp;gt;Custer (2008)&lt;/ins&gt;, &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;p. 2-56.&amp;lt;/ref&amp;gt; Trainees &lt;/ins&gt;must learn to recognise how it develops. NFPA 1403 calls for students in acquired structures to have prior training so that they understand the safety issues and can recognise normal and abnormal fire behaviour.&amp;lt;ref name=&quot;Laughlin-12-173&quot; /&amp;gt; A key transition is [[Flashover|flashover]], in which surfaces exposed to thermal radiation reach their ignition temperature more or less simultaneously and fire spreads rapidly through the whole space.&amp;lt;ref name=&quot;Janssens-2-61&quot;&amp;gt;Janssens (2008), p. 2-61.&amp;lt;/ref&amp;gt; Before flashover a fire is local and fuel-controlled; after it the whole room is burning and the fire is usually ventilation-controlled.&amp;lt;ref name=&quot;VR-4.7&quot;&amp;gt;Van Rossum (2027), §4.7.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The sources give slightly different thresholds. Custer (2008) states that flashover is triggered when the upper gas layer reaches approximately 600 °C and the radiant heat flux on unignited materials is approximately 20 kW/m².&amp;lt;ref name=&quot;Custer-2-56&quot;&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;&amp;gt;Custer (2008), p. 2-56.&amp;lt;&lt;/del&gt;/&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;ref&lt;/del&gt;&amp;gt; Van Rossum (2027) links a heat flux of about 20 kW/m² to a hot smoke layer above 500 °C, a flux at which many materials pyrolyse rapidly. He also names a lower-layer temperature above 300 to 350 °C, at which many combustibles on the floor become hot enough to ignite spontaneously.&amp;lt;ref name=&quot;VR-4.7&quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The sources give slightly different thresholds. Custer (2008) states that flashover is triggered when the upper gas layer reaches approximately 600 °C and the radiant heat flux on unignited materials is approximately 20 kW/m².&amp;lt;ref name=&quot;Custer-2-56&quot; /&amp;gt; Van Rossum (2027) links a heat flux of about 20 kW/m² to a hot smoke layer above 500 °C, a flux at which many materials pyrolyse rapidly. He also names a lower-layer temperature above 300 to 350 °C, at which many combustibles on the floor become hot enough to ignite spontaneously.&amp;lt;ref name=&quot;VR-4.7&quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Other phenomena arise when the fire is short of air. Gottuk and Lattimer (2002) describe [[Rollover|layer burning]] as the ignition of fuel-rich upper-layer gases at the interface between the hot upper layer and the cooler lower layer. It can occur only under underventilated burning.&amp;lt;ref name=&amp;quot;GL-2-55&amp;quot;&amp;gt;Gottuk and Lattimer (2002), p. 2-55.&amp;lt;/ref&amp;gt; A [[Backdraft|backdraft]] is the explosive ignition of accumulated pyrolysis gases when fresh air suddenly enters, for example when a door is opened. Van Rossum (2027) calls it a dangerous phenomenon for the fire service.&amp;lt;ref name=&amp;quot;VR-4.9&amp;quot;&amp;gt;Van Rossum (2027), §4.9.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Other phenomena arise when the fire is short of air. Gottuk and Lattimer (2002) describe [[Rollover|layer burning]] as the ignition of fuel-rich upper-layer gases at the interface between the hot upper layer and the cooler lower layer. It can occur only under underventilated burning.&amp;lt;ref name=&amp;quot;GL-2-55&amp;quot;&amp;gt;Gottuk and Lattimer (2002), p. 2-55.&amp;lt;/ref&amp;gt; A [[Backdraft|backdraft]] is the explosive ignition of accumulated pyrolysis gases when fresh air suddenly enters, for example when a door is opened. Van Rossum (2027) calls it a dangerous phenomenon for the fire service.&amp;lt;ref name=&amp;quot;VR-4.9&amp;quot;&amp;gt;Van Rossum (2027), §4.9.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Training centres can also demonstrate fire behaviour deliberately. &lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;A &lt;/del&gt;fire behaviour laboratory, also called a flashover simulator, &lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;consists of &lt;/del&gt;two shipping containers placed side by side and offset vertically to demonstrate fire behaviour.&amp;lt;ref name=&quot;AcombLeBoeuf-12-251&quot;&amp;gt;Acomb and LeBoeuf (2008), p. 12-251.&amp;lt;/ref&amp;gt; Where real fire is not needed, a smokehouse provides simulated smoke conditions. In it, performance can be observed while real fires are avoided as a safety measure.&amp;lt;ref name=&quot;Nolan-F-54&quot;&amp;gt;Nolan (2000), as cited in Iqbal and Salley (2004), p. F-54.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Training centres can also demonstrate fire behaviour deliberately. &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;One example of a &lt;/ins&gt;fire behaviour laboratory, also called a flashover simulator, &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;uses &lt;/ins&gt;two shipping containers placed side by side and offset vertically to demonstrate fire behaviour.&amp;lt;ref name=&quot;AcombLeBoeuf-12-251&quot;&amp;gt;Acomb and LeBoeuf (2008), p. 12-251.&amp;lt;/ref&amp;gt; Where real fire is not needed, a smokehouse provides simulated smoke conditions. In it, performance can be observed while real fires are avoided as a safety measure.&amp;lt;ref name=&quot;Nolan-F-54&quot;&amp;gt;Nolan (2000), as cited in Iqbal and Salley (2004), p. F-54.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Training environments ==&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Training environments ==&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;NFPA 1403 has &lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;separate &lt;/del&gt;chapters &lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;for four settings: &lt;/del&gt;acquired structures&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;, &lt;/del&gt;gas-fired and non-gas-fired buildings at training centres&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;, &lt;/del&gt;exterior props&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;, &lt;/del&gt;and exterior Class B (flammable liquid) fires.&amp;lt;ref name=&quot;Laughlin-12-173&quot; /&amp;gt; Laughlin (2008) singles out the chapter on acquired structures as especially important, because the most preventable injuries and fatalities occur in such buildings.&amp;lt;ref name=&quot;Laughlin-12-173&quot; /&amp;gt; Corbett (2008) makes a related point. In most typical training school structures, the hazards of collapse, hidden fire and highly combustible interior finish are absent. There have been serious accidents during live fire training in abandoned buildings where these hazards were present.&amp;lt;ref name=&quot;Corbett-12-130&quot;&amp;gt;Corbett (2008), p. 12-130.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;NFPA 1403 has chapters &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;covering &lt;/ins&gt;acquired structures&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;; &lt;/ins&gt;gas-fired and non-gas-fired buildings at training centres&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;; &lt;/ins&gt;exterior props&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;; &lt;/ins&gt;and exterior Class B (flammable liquid) fires.&amp;lt;ref name=&quot;Laughlin-12-173&quot; /&amp;gt; Laughlin (2008) singles out the chapter on acquired structures as especially important, because the most preventable injuries and fatalities occur in such buildings.&amp;lt;ref name=&quot;Laughlin-12-173&quot; /&amp;gt; Corbett (2008) makes a related point. In most typical training school structures, the hazards of collapse, hidden fire and highly combustible interior finish are absent. There have been serious accidents during live fire training in abandoned buildings where these hazards were present.&amp;lt;ref name=&quot;Corbett-12-130&quot;&amp;gt;Corbett (2008), p. 12-130.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;At a training centre, the first design choice for a burn building is the fuel. The two main options are Class A fuels and gas-fired props that burn liquefied petroleum (LP) gas or natural gas.&amp;lt;ref name=&amp;quot;AcombLeBoeuf-12-247&amp;quot; /&amp;gt; Class A fires are fires in ordinary combustible materials such as wood, cloth and paper, and Class B fires are fires in flammable and combustible liquids.&amp;lt;ref name=&amp;quot;Conroy-17-71&amp;quot;&amp;gt;Conroy (2008), p. 17-71.&amp;lt;/ref&amp;gt; Acomb and LeBoeuf (2008) note that the benefits of one are the drawbacks of the other, so some centres build burn buildings that can use both.&amp;lt;ref name=&amp;quot;AcombLeBoeuf-12-247&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;At a training centre, the first design choice for a burn building is the fuel. The two main options are Class A fuels and gas-fired props that burn liquefied petroleum (LP) gas or natural gas.&amp;lt;ref name=&amp;quot;AcombLeBoeuf-12-247&amp;quot; /&amp;gt; Class A fires are fires in ordinary combustible materials such as wood, cloth and paper, and Class B fires are fires in flammable and combustible liquids.&amp;lt;ref name=&amp;quot;Conroy-17-71&amp;quot;&amp;gt;Conroy (2008), p. 17-71.&amp;lt;/ref&amp;gt; Acomb and LeBoeuf (2008) note that the benefits of one are the drawbacks of the other, so some centres build burn buildings that can use both.&amp;lt;ref name=&amp;quot;AcombLeBoeuf-12-247&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l51&quot;&gt;Line 51:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 51:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Environmental constraints ==&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Environmental constraints ==&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Live fire training &lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;produces &lt;/del&gt;smoke, light&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;, &lt;/del&gt;noise and &lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;contaminated water&lt;/del&gt;, &lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;and these affect where and how it can be done&lt;/del&gt;. Visible flames, night lighting, noise and smoke have a negative impact on neighbours. Acomb and LeBoeuf (2008) therefore recommend adequate setback and visual buffering with berms, vegetation, fences and buildings.&amp;lt;ref name=&quot;AcombLeBoeuf-12-244&quot;&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;&amp;gt;Acomb and LeBoeuf (2008), p. 12-244.&amp;lt;&lt;/del&gt;/&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;ref&lt;/del&gt;&amp;gt; When potential sites are compared, the smoke plume and prevailing winds should be evaluated. Runoff can carry soot, unburned Class A or Class B fuels and firefighting chemicals.&amp;lt;ref name=&quot;AcombLeBoeuf-12-245&quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Live fire training &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;can produce &lt;/ins&gt;smoke, light &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;and &lt;/ins&gt;noise &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;that affect siting; training runoff can contain contaminants.&amp;lt;ref name=&quot;AcombLeBoeuf-12-244&quot;&amp;gt;Acomb &lt;/ins&gt;and &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;LeBoeuf (2008)&lt;/ins&gt;, &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;p. 12-244&lt;/ins&gt;.&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;&amp;lt;/ref&amp;gt;&amp;lt;ref name=&quot;AcombLeBoeuf-12-245&quot; /&amp;gt; &lt;/ins&gt;Visible flames, night lighting, noise and smoke have a negative impact on neighbours. Acomb and LeBoeuf (2008) therefore recommend adequate setback and visual buffering with berms, vegetation, fences and buildings.&amp;lt;ref name=&quot;AcombLeBoeuf-12-244&quot; /&amp;gt; When potential sites are compared, the smoke plume and prevailing winds should be evaluated. Runoff can carry soot, unburned Class A or Class B fuels and firefighting chemicals.&amp;lt;ref name=&quot;AcombLeBoeuf-12-245&quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Flammable liquid pits were becoming less common because of concerns about groundwater contamination and black smoke.&amp;lt;ref name=&amp;quot;AcombLeBoeuf-12-250&amp;quot; /&amp;gt; At airports, Boucher (2008) reports that live fire training with hydrocarbon fuels and other flammable liquids had been suspended at many airports because of local environmental constraints. The Federal Aviation Administration, the US military and private industry were developing alternative exercises that duplicate realistic fuel fire atmospheres while meeting environmental requirements.&amp;lt;ref name=&amp;quot;Boucher-21-144&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Flammable liquid pits were becoming less common because of concerns about groundwater contamination and black smoke.&amp;lt;ref name=&amp;quot;AcombLeBoeuf-12-250&amp;quot; /&amp;gt; At airports, Boucher (2008) reports that live fire training with hydrocarbon fuels and other flammable liquids had been suspended at many airports because of local environmental constraints. The Federal Aviation Administration, the US military and private industry were developing alternative exercises that duplicate realistic fuel fire atmospheres while meeting environmental requirements.&amp;lt;ref name=&amp;quot;Boucher-21-144&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;

&lt;!-- diff cache key firesb_pjbsiy42-wiki_:diff:1.41:old-3423:rev-4304:php=table --&gt;
&lt;/table&gt;</summary>
		<author><name>Lisa</name></author>
	</entry>
	<entry>
		<id>https://fire-safety.academy/w/index.php?title=Live_fire_training&amp;diff=3423&amp;oldid=prev</id>
		<title>Lisa: New FSE wiki article: Live fire training (written by Claude Opus 5.5)</title>
		<link rel="alternate" type="text/html" href="https://fire-safety.academy/w/index.php?title=Live_fire_training&amp;diff=3423&amp;oldid=prev"/>
		<updated>2026-11-07T21:25:27Z</updated>

		<summary type="html">&lt;p&gt;New FSE wiki article: Live fire training (written by Claude Opus 5.5)&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;&amp;#039;&amp;#039;&amp;#039;Live fire training&amp;#039;&amp;#039;&amp;#039; is [[Fire service training|fire service training]] in which trainees fight real, deliberately set fires under controlled conditions. It gives hands-on practice with actual fires, and at a training centre the &amp;quot;burn building&amp;quot; is the structure built for it.&amp;lt;ref name=&amp;quot;Snyder-12-194&amp;quot;&amp;gt;Snyder (2008), p. 12-194.&amp;lt;/ref&amp;gt;&amp;lt;ref name=&amp;quot;AcombLeBoeuf-12-247&amp;quot;&amp;gt;Acomb and LeBoeuf (2008), p. 12-247.&amp;lt;/ref&amp;gt; Fires may be set in acquired structures, such as vacant houses, in purpose-built burn buildings fired with gas or ordinary combustibles, in exterior props, or as exterior flammable liquid fires.&amp;lt;ref name=&amp;quot;Laughlin-12-173&amp;quot;&amp;gt;Laughlin (2008), p. 12-173.&amp;lt;/ref&amp;gt; Its value lies in realism: learning is more effective when it is relevant to the work, and realistic, intense experiences are remembered longer.&amp;lt;ref name=&amp;quot;Laughlin-12-165&amp;quot;&amp;gt;Laughlin (2008), p. 12-165.&amp;lt;/ref&amp;gt; The same realism makes it dangerous. Several US training deaths followed a flashover or rapid fire spread in a building without an adequate water supply or escape routes.&amp;lt;ref name=&amp;quot;Laughlin-12-172&amp;quot;&amp;gt;Laughlin (2008), p. 12-172.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
In the United States, NFPA 1403, &amp;#039;&amp;#039;Standard on Live Fire Training Evolutions&amp;#039;&amp;#039;, sets the rules for such exercises. It was first published in 1986, after training deaths that included two fire fighters in Boulder, Colorado, in 1982.&amp;lt;ref name=&amp;quot;Laughlin-12-172&amp;quot; /&amp;gt; By 2008 several states, among them Washington and Florida, required live fire training to follow it.&amp;lt;ref name=&amp;quot;Laughlin-12-163&amp;quot;&amp;gt;Laughlin (2008), p. 12-163.&amp;lt;/ref&amp;gt; Training centres, airport fire departments and industrial fire brigades use live fire training in different forms.&amp;lt;ref name=&amp;quot;Snyder-12-194&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;Kreckie-13-107&amp;quot;&amp;gt;Kreckie (2008), p. 13-107.&amp;lt;/ref&amp;gt; Environmental limits on smoke, runoff and fuel have also shaped how it is done.&amp;lt;ref name=&amp;quot;AcombLeBoeuf-12-250&amp;quot;&amp;gt;Acomb and LeBoeuf (2008), p. 12-250.&amp;lt;/ref&amp;gt;&amp;lt;ref name=&amp;quot;Boucher-21-144&amp;quot;&amp;gt;Boucher (2008), p. 21-144.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== Purpose and value ==&lt;br /&gt;
Laughlin (2008) explains the appeal of live fire training through the &amp;quot;laws of learning&amp;quot;. Under the law of relevance, learning is more effective when it is shown to be highly relevant to the learner&amp;#039;s life and work. Realistic training has higher relevance, which makes it tempting to provide live fire training, but Laughlin adds that the overriding safety requirements should not be forgotten.&amp;lt;ref name=&amp;quot;Laughlin-12-165&amp;quot; /&amp;gt; Under the law of emotional learning, learning that is accompanied by intense emotions tends to last longer. This fits realistic and even stressful training, but a scenario that becomes too intense can become dangerous and interfere with learning.&amp;lt;ref name=&amp;quot;Laughlin-12-165&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Live fire exercises serve the job performance requirements of NFPA 1001, the US standard for [[Firefighter professional qualifications|fire fighter professional qualifications]]. Acomb and LeBoeuf (2008) call the burn building &amp;quot;vital&amp;quot; in teaching the skills that NFPA 1001 requires, especially those that need live fire training scenarios.&amp;lt;ref name=&amp;quot;AcombLeBoeuf-12-247&amp;quot; /&amp;gt; Drill towers, smoke rooms and live fire training structures are expensive to build properly, but Laughlin (2008) considers them important for training in basic firefighting and for building confidence.&amp;lt;ref name=&amp;quot;Laughlin-12-168&amp;quot;&amp;gt;Laughlin (2008), p. 12-168.&amp;lt;/ref&amp;gt; He also notes that the value of realistic simulation brings an extra responsibility for safety.&amp;lt;ref name=&amp;quot;Laughlin-12-168&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Realism matters outside municipal fire departments too. For industrial fire brigades, Snyder (2008) advises that firefighting training be made as realistic as possible and simulate the fire conditions actually expected. He warns that too many brigades rely on stereotyped training with outside oil-pit fires or scrap-wood fires, which seldom prepares them for typical interior fires.&amp;lt;ref name=&amp;quot;Snyder-12-194&amp;quot; /&amp;gt; Public fire department training grounds near a plant are useful because they are usually arranged for hands-on training with actual fires, and such training should comply with NFPA 1403.&amp;lt;ref name=&amp;quot;Snyder-12-194&amp;quot; /&amp;gt; At US airports, each aircraft rescue and firefighting fire fighter must take part in at least one live-fire drill. The drill simulates an aircraft fire of the size typical for the index of the airport&amp;#039;s certificate.&amp;lt;ref name=&amp;quot;Kreckie-13-107&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== Fire behaviour in training ==&lt;br /&gt;
A training fire inside a structure is a compartment fire, and trainees must learn to recognise how it develops. NFPA 1403 calls for students in acquired structures to have prior training so that they understand the safety issues and can recognise normal and abnormal fire behaviour.&amp;lt;ref name=&amp;quot;Laughlin-12-173&amp;quot; /&amp;gt; A key transition is [[Flashover|flashover]], in which surfaces exposed to thermal radiation reach their ignition temperature more or less simultaneously and fire spreads rapidly through the whole space.&amp;lt;ref name=&amp;quot;Janssens-2-61&amp;quot;&amp;gt;Janssens (2008), p. 2-61.&amp;lt;/ref&amp;gt; Before flashover a fire is local and fuel-controlled; after it the whole room is burning and the fire is usually ventilation-controlled.&amp;lt;ref name=&amp;quot;VR-4.7&amp;quot;&amp;gt;Van Rossum (2027), §4.7.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
The sources give slightly different thresholds. Custer (2008) states that flashover is triggered when the upper gas layer reaches approximately 600 °C and the radiant heat flux on unignited materials is approximately 20 kW/m².&amp;lt;ref name=&amp;quot;Custer-2-56&amp;quot;&amp;gt;Custer (2008), p. 2-56.&amp;lt;/ref&amp;gt; Van Rossum (2027) links a heat flux of about 20 kW/m² to a hot smoke layer above 500 °C, a flux at which many materials pyrolyse rapidly. He also names a lower-layer temperature above 300 to 350 °C, at which many combustibles on the floor become hot enough to ignite spontaneously.&amp;lt;ref name=&amp;quot;VR-4.7&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Other phenomena arise when the fire is short of air. Gottuk and Lattimer (2002) describe [[Rollover|layer burning]] as the ignition of fuel-rich upper-layer gases at the interface between the hot upper layer and the cooler lower layer. It can occur only under underventilated burning.&amp;lt;ref name=&amp;quot;GL-2-55&amp;quot;&amp;gt;Gottuk and Lattimer (2002), p. 2-55.&amp;lt;/ref&amp;gt; A [[Backdraft|backdraft]] is the explosive ignition of accumulated pyrolysis gases when fresh air suddenly enters, for example when a door is opened. Van Rossum (2027) calls it a dangerous phenomenon for the fire service.&amp;lt;ref name=&amp;quot;VR-4.9&amp;quot;&amp;gt;Van Rossum (2027), §4.9.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Training centres can also demonstrate fire behaviour deliberately. A fire behaviour laboratory, also called a flashover simulator, consists of two shipping containers placed side by side and offset vertically to demonstrate fire behaviour.&amp;lt;ref name=&amp;quot;AcombLeBoeuf-12-251&amp;quot;&amp;gt;Acomb and LeBoeuf (2008), p. 12-251.&amp;lt;/ref&amp;gt; Where real fire is not needed, a smokehouse provides simulated smoke conditions. In it, performance can be observed while real fires are avoided as a safety measure.&amp;lt;ref name=&amp;quot;Nolan-F-54&amp;quot;&amp;gt;Nolan (2000), as cited in Iqbal and Salley (2004), p. F-54.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== Training environments ==&lt;br /&gt;
NFPA 1403 has separate chapters for four settings: acquired structures, gas-fired and non-gas-fired buildings at training centres, exterior props, and exterior Class B (flammable liquid) fires.&amp;lt;ref name=&amp;quot;Laughlin-12-173&amp;quot; /&amp;gt; Laughlin (2008) singles out the chapter on acquired structures as especially important, because the most preventable injuries and fatalities occur in such buildings.&amp;lt;ref name=&amp;quot;Laughlin-12-173&amp;quot; /&amp;gt; Corbett (2008) makes a related point. In most typical training school structures, the hazards of collapse, hidden fire and highly combustible interior finish are absent. There have been serious accidents during live fire training in abandoned buildings where these hazards were present.&amp;lt;ref name=&amp;quot;Corbett-12-130&amp;quot;&amp;gt;Corbett (2008), p. 12-130.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
At a training centre, the first design choice for a burn building is the fuel. The two main options are Class A fuels and gas-fired props that burn liquefied petroleum (LP) gas or natural gas.&amp;lt;ref name=&amp;quot;AcombLeBoeuf-12-247&amp;quot; /&amp;gt; Class A fires are fires in ordinary combustible materials such as wood, cloth and paper, and Class B fires are fires in flammable and combustible liquids.&amp;lt;ref name=&amp;quot;Conroy-17-71&amp;quot;&amp;gt;Conroy (2008), p. 17-71.&amp;lt;/ref&amp;gt; Acomb and LeBoeuf (2008) note that the benefits of one are the drawbacks of the other, so some centres build burn buildings that can use both.&amp;lt;ref name=&amp;quot;AcombLeBoeuf-12-247&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Some large centres chose gas. One of the main motivations for the design of the Tarrant County College Fire Service Training Center in Fort Worth, Texas, was live fire training without the safety risks of acquired structures. According to the college, it was one of the largest computer-controlled, gas-fired facilities in the world, with six separate live fire buildings.&amp;lt;ref name=&amp;quot;Laughlin-12-168&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Exterior props are typically gas-fired, in most cases with LP gas, because natural gas flames are difficult to see in daylight. Vendors offer props that simulate car, fuel spill, tank, dumpster, railcar, aircraft and shipboard fires, among others.&amp;lt;ref name=&amp;quot;AcombLeBoeuf-12-250&amp;quot; /&amp;gt; Mobile gas-fired props bring live fire training to students in statewide and regional programmes, although a trailer cannot provide the proportions of a burn building.&amp;lt;ref name=&amp;quot;AcombLeBoeuf-12-250&amp;quot; /&amp;gt; Class A materials can also be burned outdoors, for example in a junked car. All closed containers, such as tanks, bumpers, pistons and shock absorbers, must first be removed to prevent bursting, and upholstery and plastics with hazardous emissions should also be removed.&amp;lt;ref name=&amp;quot;AcombLeBoeuf-12-250&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== Burn building design ==&lt;br /&gt;
Acomb and LeBoeuf (2008) describe the burn building as usually the first training structure provided at a training centre.&amp;lt;ref name=&amp;quot;AcombLeBoeuf-12-247&amp;quot; /&amp;gt; It can deteriorate quickly if it is not designed correctly, and there are three main causes of damage. The first is heat, which can reach 2000 °F (1093 °C) where flames impinge directly, as on ceilings above training fires. The second is thermal shock when heated surfaces are sprayed with cold water. The third is abuse inherent in training, such as hose streams and impacts from tools and gear.&amp;lt;ref name=&amp;quot;AcombLeBoeuf-12-247&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
No building material is immune to these conditions. Masonry cracks and gradually deteriorates, steel warps and corrodes, and concrete cracks and spalls.&amp;lt;ref name=&amp;quot;AcombLeBoeuf-12-247&amp;quot; /&amp;gt; The structural elements are therefore protected with thermal linings. For ceilings these are mostly proprietary products that differ in materials and installation, so they should be judged on initial and long-term cost, verifiable durability and insulating capability, and references.&amp;lt;ref name=&amp;quot;AcombLeBoeuf-12-247&amp;quot; /&amp;gt; Steel is not an insulator and tends to warp, and refractory (calcium aluminate) concrete should not be used for structural components because of its record of severe damage.&amp;lt;ref name=&amp;quot;AcombLeBoeuf-12-247&amp;quot; /&amp;gt; The two most common types of burn building are combinations of concrete and masonry and pre-engineered steel buildings.&amp;lt;ref name=&amp;quot;AcombLeBoeuf-12-247-248&amp;quot;&amp;gt;Acomb and LeBoeuf (2008), pp. 12-247–12-248.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Details serve both training and safety. Possible features include various roof pitches and ventilation cutouts, durable doors and shutters that tolerate heat while keeping in smoke, drainage scuppers, forced-entry doors, standpipes and temperature monitoring systems.&amp;lt;ref name=&amp;quot;AcombLeBoeuf-12-248&amp;quot;&amp;gt;Acomb and LeBoeuf (2008), p. 12-248.&amp;lt;/ref&amp;gt; The building is best accessible from all sides and lockable where the grounds are not fenced.&amp;lt;ref name=&amp;quot;AcombLeBoeuf-12-248&amp;quot; /&amp;gt; A burn building combined with a training tower saves site space, whereas separate structures allow live fire training and tower drills to run at the same time.&amp;lt;ref name=&amp;quot;AcombLeBoeuf-12-249&amp;quot;&amp;gt;Acomb and LeBoeuf (2008), p. 12-249.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Experience in designing schools or fire stations does not provide the expertise needed for live fire training structures. Architects and engineers without training centre experience should therefore team with specialist consultants.&amp;lt;ref name=&amp;quot;AcombLeBoeuf-12-241&amp;quot;&amp;gt;Acomb and LeBoeuf (2008), p. 12-241.&amp;lt;/ref&amp;gt; The authors treat training centres together with [[Fire station design|fire station design]], since needs assessment, master planning, site selection and design follow the same process for both.&amp;lt;ref name=&amp;quot;AcombLeBoeuf-12-251&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
The building also needs a budget after it opens. The operations and maintenance budget includes training fuel and any abatement of noise, smoke and runoff. It also covers routine structural engineering evaluations of the burn building, as called for by NFPA 1403.&amp;lt;ref name=&amp;quot;AcombLeBoeuf-12-246&amp;quot;&amp;gt;Acomb and LeBoeuf (2008), p. 12-246.&amp;lt;/ref&amp;gt; The design draws on several documents, including NFPA 1402, &amp;#039;&amp;#039;Guide to Building Fire Service Training Centers&amp;#039;&amp;#039;, NFPA 1403, and the gas codes NFPA 54 and NFPA 58.&amp;lt;ref name=&amp;quot;AcombLeBoeuf-12-245&amp;quot;&amp;gt;Acomb and LeBoeuf (2008), p. 12-245.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== Safety rules and NFPA 1403 ==&lt;br /&gt;
Laughlin (2008) reads the training injuries and deaths of the previous 25 years as a warning. Instructors can forget that a realistic scenario can have disastrous results when safety is not the paramount consideration.&amp;lt;ref name=&amp;quot;Laughlin-12-172&amp;quot; /&amp;gt; Such training deaths and injuries form part of the wider record of [[Firefighter injuries and fatalities|firefighter injuries and fatalities]]. NFPA 1403 was developed after numerous training deaths, especially those of two fire fighters at Boulder in 1982 in an abandoned wood-frame building.&amp;lt;ref name=&amp;quot;Laughlin-12-172&amp;quot; /&amp;gt; There, rapid fire spread across a combustible low-density fiberboard ceiling, an inadequate water supply, inadequate exits and a general lack of planning contributed to the deaths.&amp;lt;ref name=&amp;quot;Laughlin-12-172&amp;quot; /&amp;gt; During its development, NFPA 1403 drew approximately 1,000 comments at the Report on Comments stage in 1985, and the first edition followed in 1986.&amp;lt;ref name=&amp;quot;Loflin-12-109&amp;quot;&amp;gt;Loflin (2008), p. 12-109.&amp;lt;/ref&amp;gt;&amp;lt;ref name=&amp;quot;Laughlin-12-172&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
The guidance was not always followed. In 1987 three fire fighters died in an exercise in an old frame house in Milford, Michigan, where multiple fires had been set to create a realistic scenario. The scenario did not comply with NFPA 1403: planning was lacking, escape paths were insufficient, the water supply was inadequate and large amounts of accelerants were used. Safety was not a sufficient priority to prevent an unanticipated flashover while fire fighters were still inside.&amp;lt;ref name=&amp;quot;Laughlin-12-172&amp;quot; /&amp;gt; In a Florida incident in 2002, a fire was set in a vacant concrete-block dwelling to accompany search and rescue training. The two trainees had no ready water supply and there were insufficient escape paths.&amp;lt;ref name=&amp;quot;Laughlin-12-173&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
The exercise had designated [[Incident safety officer|safety officers]] and a rapid intervention team, but the fuel load contributed to a flashover only 3 minutes later.&amp;lt;ref name=&amp;quot;Laughlin-12-173&amp;quot; /&amp;gt; Four instructors inside the building as interior safety officers escaped, but the lieutenant and the fire fighter in the exercise died of smoke inhalation and thermal injuries.&amp;lt;ref name=&amp;quot;Laughlin-12-173&amp;quot; /&amp;gt; After a 19-year-old trainee died in New York in 2001, the officer supervising the exercise was convicted of criminally negligent homicide. The state then offered two programmes on live fire training safety, both referring to NFPA 1403.&amp;lt;ref name=&amp;quot;Laughlin-12-173&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
NFPA 1403 calls the ongoing training of fire fighters &amp;quot;the cornerstone of good fire protection in today&amp;#039;s world&amp;quot;. It adds that the benefits of live fire training &amp;quot;can be negated by the injuries and deaths suffered by fire fighters under unsafe and poorly supervised training conditions&amp;quot;.&amp;lt;ref name=&amp;quot;Laughlin-12-173&amp;quot; /&amp;gt; A US Nuclear Regulatory Commission report listed the 2002 edition of NFPA 1403 as current in 2004.&amp;lt;ref name=&amp;quot;IqbalSalley-E-11&amp;quot;&amp;gt;Iqbal and Salley (2004), p. E-11.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
In acquired structures, the building must be specially prepared to minimise the factors that contribute to uncontrolled burning, and fuel loads are limited. Before any training fire, participants must become familiar with the building, its exits and the plan for the exercise.&amp;lt;ref name=&amp;quot;Laughlin-12-173&amp;quot; /&amp;gt; Adequate water supplies and enough instructors to supervise the burn must be available, and flammable or combustible liquids may not be used to fuel the fire.&amp;lt;ref name=&amp;quot;Laughlin-12-173&amp;quot; /&amp;gt; The standard also requires accurate and complete training records.&amp;lt;ref name=&amp;quot;Laughlin-12-173&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== Environmental constraints ==&lt;br /&gt;
Live fire training produces smoke, light, noise and contaminated water, and these affect where and how it can be done. Visible flames, night lighting, noise and smoke have a negative impact on neighbours. Acomb and LeBoeuf (2008) therefore recommend adequate setback and visual buffering with berms, vegetation, fences and buildings.&amp;lt;ref name=&amp;quot;AcombLeBoeuf-12-244&amp;quot;&amp;gt;Acomb and LeBoeuf (2008), p. 12-244.&amp;lt;/ref&amp;gt; When potential sites are compared, the smoke plume and prevailing winds should be evaluated. Runoff can carry soot, unburned Class A or Class B fuels and firefighting chemicals.&amp;lt;ref name=&amp;quot;AcombLeBoeuf-12-245&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Flammable liquid pits were becoming less common because of concerns about groundwater contamination and black smoke.&amp;lt;ref name=&amp;quot;AcombLeBoeuf-12-250&amp;quot; /&amp;gt; At airports, Boucher (2008) reports that live fire training with hydrocarbon fuels and other flammable liquids had been suspended at many airports because of local environmental constraints. The Federal Aviation Administration, the US military and private industry were developing alternative exercises that duplicate realistic fuel fire atmospheres while meeting environmental requirements.&amp;lt;ref name=&amp;quot;Boucher-21-144&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Firefighting foam adds its own problems. Scheffey (2008) lists firefighting training evolutions among the discharge scenarios to consider when assessing the environmental impact of foam. Training offers greater opportunities than real incidents to control foam flow, particularly by collecting it.&amp;lt;ref name=&amp;quot;Scheffey-17-68&amp;quot;&amp;gt;Scheffey (2008), p. 17-68.&amp;lt;/ref&amp;gt; New techniques with simulated pool fires and simulated foams were available.&amp;lt;ref name=&amp;quot;Scheffey-17-69&amp;quot;&amp;gt;Scheffey (2008), p. 17-69.&amp;lt;/ref&amp;gt; In uncontrolled fires, spills and live fire training scenarios, foams may contain suspended fuels that become emulsified in the foam-water solution.&amp;lt;ref name=&amp;quot;Scheffey2002-4-119&amp;quot;&amp;gt;Scheffey (2002), p. 4-119.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== See also ==&lt;br /&gt;
* [[Fire department organisation]]&lt;br /&gt;
* [[Rapid intervention crew]]&lt;br /&gt;
* [[Self-contained breathing apparatus]]&lt;br /&gt;
* [[Aircraft rescue and firefighting]]&lt;br /&gt;
* [[Industrial fire brigade]]&lt;br /&gt;
* [[NFPA 1500]]&lt;br /&gt;
&lt;br /&gt;
== Notes ==&lt;br /&gt;
&amp;lt;references /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== References ==&lt;br /&gt;
* Acomb, D. J., &amp;amp; LeBoeuf, R. M. (2008). Fire rescue stations and fire service training centers. In A. E. Cote, C. C. Grant, J. R. Hall, Jr., &amp;amp; R. E. Solomon (Eds.), &amp;#039;&amp;#039;Fire protection handbook&amp;#039;&amp;#039; (20th ed., pp. 12-233–12-251). National Fire Protection Association.&lt;br /&gt;
* Boucher, B. (2008). Aviation. In A. E. Cote, C. C. Grant, J. R. Hall, Jr., &amp;amp; R. E. Solomon (Eds.), &amp;#039;&amp;#039;Fire protection handbook&amp;#039;&amp;#039; (20th ed., pp. 21-135–21-149). National Fire Protection Association.&lt;br /&gt;
* Conroy, M. T. (2008). Fire extinguisher use and maintenance. In A. E. Cote, C. C. Grant, J. R. Hall, Jr., &amp;amp; R. E. Solomon (Eds.), &amp;#039;&amp;#039;Fire protection handbook&amp;#039;&amp;#039; (20th ed., pp. 17-71–17-92). National Fire Protection Association.&lt;br /&gt;
* Corbett, G. P. (2008). Effect of building construction and fire protection systems on fire fighter safety. In A. E. Cote, C. C. Grant, J. R. Hall, Jr., &amp;amp; R. E. Solomon (Eds.), &amp;#039;&amp;#039;Fire protection handbook&amp;#039;&amp;#039; (20th ed., pp. 12-127–12-141). National Fire Protection Association.&lt;br /&gt;
* Custer, R. L. P. (2008). Dynamics of compartment fire growth. In A. E. Cote, C. C. Grant, J. R. Hall, Jr., &amp;amp; R. E. Solomon (Eds.), &amp;#039;&amp;#039;Fire protection handbook&amp;#039;&amp;#039; (20th ed., pp. 2-49–2-58). National Fire Protection Association.&lt;br /&gt;
* Gottuk, D. T., &amp;amp; Lattimer, B. Y. (2002). Effect of combustion conditions on species production. In P. J. DiNenno, D. Drysdale, C. L. Beyler, W. D. Walton, R. L. P. Custer, J. R. Hall Jr., &amp;amp; J. M. Watts Jr. (Eds.), &amp;#039;&amp;#039;SFPE handbook of fire protection engineering&amp;#039;&amp;#039; (3rd ed., pp. 2-54–2-82). National Fire Protection Association; Society of Fire Protection Engineers.&lt;br /&gt;
* Iqbal, N., &amp;amp; Salley, M. H. (2004). &amp;#039;&amp;#039;Fire Dynamics Tools (FDTs): Quantitative fire hazard analysis methods for the U.S. Nuclear Regulatory Commission Fire Protection Inspection Program&amp;#039;&amp;#039; (NUREG-1805). U.S. Nuclear Regulatory Commission, Office of Nuclear Reactor Regulation.&lt;br /&gt;
* Janssens, M. L. (2008). Basics of fire containment. In A. E. Cote, C. C. Grant, J. R. Hall, Jr., &amp;amp; R. E. Solomon (Eds.), &amp;#039;&amp;#039;Fire protection handbook&amp;#039;&amp;#039; (20th ed., pp. 2-59–2-74). National Fire Protection Association.&lt;br /&gt;
* Kreckie, J. (2008). Aircraft rescue and fire fighting (ARFF). In A. E. Cote, C. C. Grant, J. R. Hall, Jr., &amp;amp; R. E. Solomon (Eds.), &amp;#039;&amp;#039;Fire protection handbook&amp;#039;&amp;#039; (20th ed., pp. 13-99–13-115). National Fire Protection Association.&lt;br /&gt;
* Laughlin, J. W. (2008). Training programs for fire and emergency service personnel. In A. E. Cote, C. C. Grant, J. R. Hall, Jr., &amp;amp; R. E. Solomon (Eds.), &amp;#039;&amp;#039;Fire protection handbook&amp;#039;&amp;#039; (20th ed., pp. 12-161–12-175). National Fire Protection Association.&lt;br /&gt;
* Loflin, M. E. (2008). Safety, medical, and health issues and programs. In A. E. Cote, C. C. Grant, J. R. Hall, Jr., &amp;amp; R. E. Solomon (Eds.), &amp;#039;&amp;#039;Fire protection handbook&amp;#039;&amp;#039; (20th ed., pp. 12-107–12-125). National Fire Protection Association.&lt;br /&gt;
* Scheffey, J. L. (2002). Foam agents and AFFF system design considerations. In P. J. DiNenno, D. Drysdale, C. L. Beyler, W. D. Walton, R. L. P. Custer, J. R. Hall Jr., &amp;amp; J. M. Watts Jr. (Eds.), &amp;#039;&amp;#039;SFPE handbook of fire protection engineering&amp;#039;&amp;#039; (3rd ed., pp. 4-88–4-122). National Fire Protection Association; Society of Fire Protection Engineers.&lt;br /&gt;
* Scheffey, J. L. (2008). Foam extinguishing agents and systems. In A. E. Cote, C. C. Grant, J. R. Hall, Jr., &amp;amp; R. E. Solomon (Eds.), &amp;#039;&amp;#039;Fire protection handbook&amp;#039;&amp;#039; (20th ed., pp. 17-45–17-70). National Fire Protection Association.&lt;br /&gt;
* Snyder, M. (2008). Industrial fire loss prevention. In A. E. Cote, C. C. Grant, J. R. Hall, Jr., &amp;amp; R. E. Solomon (Eds.), &amp;#039;&amp;#039;Fire protection handbook&amp;#039;&amp;#039; (20th ed., pp. 12-177–12-198). National Fire Protection Association.&lt;br /&gt;
* Van Rossum, E. (2027). &amp;#039;&amp;#039;Introduction to Fire Safety Engineering&amp;#039;&amp;#039;. Fire Safety Academy.&lt;br /&gt;
&lt;br /&gt;
[[Category:Firefighting &amp;amp; Fire Service]]&lt;/div&gt;</summary>
		<author><name>Lisa</name></author>
	</entry>
</feed>