<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://fire-safety.academy/w/index.php?action=history&amp;feed=atom&amp;title=Large-scale_facade_fire_test</id>
	<title>Large-scale facade fire test - Revision history</title>
	<link rel="self" type="application/atom+xml" href="https://fire-safety.academy/w/index.php?action=history&amp;feed=atom&amp;title=Large-scale_facade_fire_test"/>
	<link rel="alternate" type="text/html" href="https://fire-safety.academy/w/index.php?title=Large-scale_facade_fire_test&amp;action=history"/>
	<updated>2026-11-24T12:22:46Z</updated>
	<subtitle>Revision history for this page on the wiki</subtitle>
	<generator>MediaWiki 1.43.11</generator>
	<entry>
		<id>https://fire-safety.academy/w/index.php?title=Large-scale_facade_fire_test&amp;diff=9678&amp;oldid=prev</id>
		<title>Mark: New FSE wiki article: Large-scale facade fire test (written by GPT-6)</title>
		<link rel="alternate" type="text/html" href="https://fire-safety.academy/w/index.php?title=Large-scale_facade_fire_test&amp;diff=9678&amp;oldid=prev"/>
		<updated>2026-11-23T19:12:17Z</updated>

		<summary type="html">&lt;p&gt;New FSE wiki article: Large-scale facade fire test (written by GPT-6)&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;A &amp;#039;&amp;#039;&amp;#039;large-scale facade fire test&amp;#039;&amp;#039;&amp;#039; exposes an assembled external wall system to flames and measures how far fire travels over or within it. One arrangement represents a fully developed room fire venting through a window. Flames leaving the opening heat the wall above, where cladding, joints and the construction behind the outer face can affect the outcome.&amp;lt;ref name=&amp;quot;isorich&amp;quot;&amp;gt;Janssens (2008), §2.5, p. 2-69.&amp;lt;/ref&amp;gt;&amp;lt;ref name=&amp;quot;auswall&amp;quot;&amp;gt;Australian Building Codes Board (2020), §9.6, pp. 80–81.&amp;lt;/ref&amp;gt;&amp;lt;ref name=&amp;quot;joints&amp;quot;&amp;gt;Ministry of Business, Innovation and Employment (2013), commentary on §4.6, p. 135.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
A small specimen can show how readily a material burns. A wall test addresses an additional question about a [[Facade fire|façade fire]]. Can flames travel beyond the area directly exposed when the materials are assembled as they would be on a building? The answer applies to the construction and exposure described in the test report.&amp;lt;ref name=&amp;quot;isorich&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;joints&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;nzwall&amp;quot;&amp;gt;Ministry of Business, Innovation and Employment (2025), §§4.6.1–4.6.3, pp. 47–49.&amp;lt;/ref&amp;gt;&lt;br /&gt;
[[File:fse-large-scale-facade-fire-test-v1.svg|thumb|upright=1.5|alt=Side section of a fire compartment with flames emerging from a window and turning upward along the outer wall.|Flames emerging from a compartment can expose cladding above the opening. Based on Australian Building Codes Board (2020), §9.6, pp. 80–81.]]&lt;br /&gt;
&lt;br /&gt;
== What the specimen represents ==&lt;br /&gt;
The outer face is only one part of a wall. A joint can expose material behind it, and a cavity can provide a route for spread past the part visible from outside. The arrangement of layers, joints and [[Cavity barrier|cavity barriers]] therefore matters when comparing the tested construction with a proposed wall. A material’s [[Combustibility|combustibility]] is one input to this comparison.&amp;lt;ref name=&amp;quot;joints&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;nzwall&amp;quot; /&amp;gt;&lt;br /&gt;
[[File:fse-large-scale-facade-fire-test-v2.svg|thumb|upright=1.5|alt=Section through a backing wall, cavity, cladding joint and cavity barrier at the level of the floor.|Joints and cavity details help determine how well a test specimen represents the proposed wall. Based on Ministry of Business, Innovation and Employment (2025), §§4.6.1–4.6.3, pp. 47–49.]]&lt;br /&gt;
&lt;br /&gt;
== Exposure and observations ==&lt;br /&gt;
In the ISO 13785-2 arrangement described by Janssens, flames emerge from a room opening beside a return wall. The corner concentrates the exposure. Other methods use different burners and wall geometries. Measurements or limits from one method acquire their meaning from that particular arrangement.&amp;lt;ref name=&amp;quot;isorich&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
[[External flaming]] from the opening is the imposed exposure. Sustained [[Upward flame spread|upward flame spread]] on the cladding is a response to that exposure. Observations of the flame front and temperatures at specified locations help distinguish the two. The method determines which observations count towards the result.&amp;lt;ref name=&amp;quot;isorich&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;nzwall&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== How countries use the evidence ==&lt;br /&gt;
Australia’s 2020 verification handbook discusses AS 5113:2016 with Amendment 1. Its vertical-spread scenario also considers falling debris, openings on higher floors and fire spread to adjacent buildings. A classification of the tested system is one part of this building-level assessment.&amp;lt;ref name=&amp;quot;auswall&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
New Zealand’s 2025 C/VM2 gives a specific example. For the multi-level buildings covered by §4.6.2, it specifies a design exposure of 50 kW/m² for importance levels 2 and 3, or 90 kW/m² for level 4, for 15 minutes in either case. These are scenario inputs. The same subsection separately identifies the construction or test evidence needed for the complete cladding system.&amp;lt;ref name=&amp;quot;nzwall&amp;quot; /&amp;gt;&lt;br /&gt;
[[File:fse-large-scale-facade-fire-test-v3.svg|thumb|upright=1.5|alt=Bar chart showing design exposures of 50 and 90 kilowatts per square metre, each for 15 minutes.|C/VM2 assigns different design heat fluxes to the specified building importance levels for the same duration. Based on Ministry of Business, Innovation and Employment (2025), §§4.6.1–4.6.3, pp. 47–49.]]&lt;br /&gt;
&lt;br /&gt;
== Applying a report to a building ==&lt;br /&gt;
A review starts with the method, the wall actually built for the test, and the proposed detail. Matching the product name leaves open questions about joints and cavities. A [[Single Burning Item test]] can describe a product’s contribution to fire growth in a corner. Large-scale [[Fire testing|fire testing]] supplies evidence about the path through the assembled wall.&amp;lt;ref name=&amp;quot;joints&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;nzwall&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;sbi&amp;quot;&amp;gt;Hirschler (2008), §6.3, pp. 6-48–6-49.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== See also ==&lt;br /&gt;
* [[Reaction to fire]]&lt;br /&gt;
* [[Glass breakage in fire]]&lt;br /&gt;
* [[Sandwich panel]]&lt;br /&gt;
&lt;br /&gt;
== Notes ==&lt;br /&gt;
&amp;lt;references /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== References ==&lt;br /&gt;
* Australian Building Codes Board. (2020). &amp;#039;&amp;#039;[https://watermark.abcb.gov.au/sites/default/files/resources/2020/Handbook_Fire_Safety_Verification_Method.pdf Fire safety verification method]&amp;#039;&amp;#039; (Handbook, version 1.1).&lt;br /&gt;
* Hirschler, M. M. (2008). Concepts and protocols of fire testing. In A. E. Cote (Ed.), &amp;#039;&amp;#039;Fire protection handbook&amp;#039;&amp;#039; (20th ed.). National Fire Protection Association.&lt;br /&gt;
* Janssens, M. L. (2008). Basics of fire containment. In A. E. Cote (Ed.), &amp;#039;&amp;#039;Fire protection handbook&amp;#039;&amp;#039; (20th ed.). National Fire Protection Association.&lt;br /&gt;
* Ministry of Business, Innovation and Employment. (2013). &amp;#039;&amp;#039;[https://www.building.govt.nz/assets/Uploads/building-code-compliance/c-protection-from-fire/asvm/cvm2-protection-from-fire-amendment-2-commentary.pdf Commentary for building code clauses C1–C6 and verification method C/VM2]&amp;#039;&amp;#039; (amended December 2013). New Zealand Government.&lt;br /&gt;
* Ministry of Business, Innovation and Employment. (2025). &amp;#039;&amp;#039;[https://www.building.govt.nz/assets/Uploads/building-code-compliance/c-protection-from-fire/asvm/c-protection-from-fire-vm2-second-edition.pdf C protection from fire: Verification method C/VM2]&amp;#039;&amp;#039; (2nd ed.). New Zealand Government.&lt;br /&gt;
&lt;br /&gt;
[[Category:Materials &amp;amp; Fire Testing]]&lt;/div&gt;</summary>
		<author><name>Mark</name></author>
	</entry>
</feed>