<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://fire-safety.academy/w/index.php?action=history&amp;feed=atom&amp;title=Industrial_occupancy</id>
	<title>Industrial occupancy - Revision history</title>
	<link rel="self" type="application/atom+xml" href="https://fire-safety.academy/w/index.php?action=history&amp;feed=atom&amp;title=Industrial_occupancy"/>
	<link rel="alternate" type="text/html" href="https://fire-safety.academy/w/index.php?title=Industrial_occupancy&amp;action=history"/>
	<updated>2026-11-21T22:01:12Z</updated>
	<subtitle>Revision history for this page on the wiki</subtitle>
	<generator>MediaWiki 1.43.11</generator>
	<entry>
		<id>https://fire-safety.academy/w/index.php?title=Industrial_occupancy&amp;diff=9454&amp;oldid=prev</id>
		<title>Peter: Wiki review: corrected 4 errors: grammar (3), typo (Claude Opus 5.5)</title>
		<link rel="alternate" type="text/html" href="https://fire-safety.academy/w/index.php?title=Industrial_occupancy&amp;diff=9454&amp;oldid=prev"/>
		<updated>2026-11-15T23:49:26Z</updated>

		<summary type="html">&lt;p&gt;Wiki review: corrected 4 errors: grammar (3), typo (Claude Opus 5.5)&lt;/p&gt;
&lt;table style=&quot;background-color: #fff; color: #202122;&quot; data-mw=&quot;interface&quot;&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;tr class=&quot;diff-title&quot; lang=&quot;en&quot;&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;← Older revision&lt;/td&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;Revision as of 00:49, 16 November 2026&lt;/td&gt;
				&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l5&quot;&gt;Line 5:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 5:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Processes and hazard identification ==&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Processes and hazard identification ==&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[[Sprinkler hazard classification]] concerns the fire challenge represented in a suppression design. [[Hazardous area classification]] addresses a different question concerning potentially hazardous atmospheres and equipment. Neither can be inferred completely from the word industrial. The handbook emphasises the diversity of fuels, processes and possible explosions within industrial facilities. The relevant classification needs the actual materials and operating conditions. &amp;lt;ref name=&amp;quot;FPH-22a95fc6&amp;quot;&amp;gt;Cote et al. (2008), §20.18, p. 20-204.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[[Sprinkler hazard classification]] concerns the fire challenge represented in a suppression design. [[Hazardous area classification]] addresses a different question concerning potentially hazardous atmospheres and equipment. Neither can be inferred completely from the word industrial. The handbook emphasises the diversity of fuels, processes and possible explosions within industrial facilities. The relevant classification needs the actual materials and operating conditions. &amp;lt;ref name=&amp;quot;FPH-22a95fc6&amp;quot;&amp;gt;Cote et al. (2008), §20.18, p. 20-204.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[[File:fse-industrial_occupancy-v1.svg|thumb|upright=1.5|alt=Industrial occupancy: Material, Process, Ignition source, Possible consequence|Processes and hazard identification for &lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;Industrial &lt;/del&gt;occupancy.]]&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[[File:fse-industrial_occupancy-v1.svg|thumb|upright=1.5|alt=Industrial occupancy: Material, Process, Ignition source, Possible consequence|Processes and hazard identification for &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;an industrial &lt;/ins&gt;occupancy.]]&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[[Ammonia refrigeration]] is one example of a specialised industrial system requiring its own hazard information. Its name does not provide the inventory, layout or release conditions needed for assessment. The broader method identifies equipment and materials before constructing incident scenarios. The same approach separates process-specific hazards from ordinary building hazards such as electrical equipment, heating and maintenance work. &amp;lt;ref name=&amp;quot;FPH-22a95fc6&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;MEACHAM-b6373d4d&amp;quot;&amp;gt;Meacham (2002), pp. 5-155–5-156.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[[Ammonia refrigeration]] is one example of a specialised industrial system requiring its own hazard information. Its name does not provide the inventory, layout or release conditions needed for assessment. The broader method identifies equipment and materials before constructing incident scenarios. The same approach separates process-specific hazards from ordinary building hazards such as electrical equipment, heating and maintenance work. &amp;lt;ref name=&amp;quot;FPH-22a95fc6&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;MEACHAM-b6373d4d&amp;quot;&amp;gt;Meacham (2002), pp. 5-155–5-156.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l13&quot;&gt;Line 13:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 13:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Movement, process change and preparedness ==&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Movement, process change and preparedness ==&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[[Common path of travel]] is one feature of the escape arrangement considered in industrial protection. The handbook identifies locked and obstructed exits among the contributors to serious losses. Route geometry and usable doors therefore need to be considered together. A route shown on a drawing provides little protection if operating practices prevent its use. &amp;lt;ref name=&amp;quot;FPH-2d7261ea&amp;quot;&amp;gt;Cote et al. (2008), §20.18, pp. 20-204, 20-209.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[[Common path of travel]] is one feature of the escape arrangement considered in industrial protection. The handbook identifies locked and obstructed exits among the contributors to serious losses. Route geometry and usable doors therefore need to be considered together. A route shown on a drawing provides little protection if operating practices prevent its use. &amp;lt;ref name=&amp;quot;FPH-2d7261ea&amp;quot;&amp;gt;Cote et al. (2008), §20.18, pp. 20-204, 20-209.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[[File:fse-industrial_occupancy-v2.svg|thumb|upright=1.5|alt=Industrial occupancy: Changed process, Changed hazard, Protection review, Emergency roles|Movement, process change and preparedness for &lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;Industrial &lt;/del&gt;occupancy.]]&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[[File:fse-industrial_occupancy-v2.svg|thumb|upright=1.5|alt=Industrial occupancy: Changed process, Changed hazard, Protection review, Emergency roles|Movement, process change and preparedness for &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;an industrial &lt;/ins&gt;occupancy.]]&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;An [[&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;Emergency &lt;/del&gt;action plan]] connects warning with actions such as evacuation, equipment shutdown and an authorised response. The handbook describes planning with the responding fire service and identifying hazardous materials on site plans. It also discusses exercises as a way to identify deficiencies. These activities make the plan a description of coordinated actions rather than a list of telephone numbers. &amp;lt;ref name=&quot;FPH-b054bd8c&quot;&amp;gt;Cote et al. (2008), §20.18, p. 20-209.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;An [[&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;emergency &lt;/ins&gt;action plan]] connects warning with actions such as evacuation, equipment shutdown and an authorised response. The handbook describes planning with the responding fire service and identifying hazardous materials on site plans. It also discusses exercises as a way to identify deficiencies. These activities make the plan a description of coordinated actions rather than a list of telephone numbers. &amp;lt;ref name=&quot;FPH-b054bd8c&quot;&amp;gt;Cote et al. (2008), §20.18, p. 20-209.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Changes in a process can alter the hazard without changing the building&amp;#039;s general occupancy. The handbook specifically identifies changes in fuel load or hazard beyond a sprinkler system&amp;#039;s original design basis. This creates a need to reassess the relationship between the hazard and its protection. The existence of installed equipment is not evidence that the current operation remains within its intended scope. &amp;lt;ref name=&amp;quot;FPH-22a95fc6&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Changes in a process can alter the hazard without changing the building&amp;#039;s general occupancy. The handbook specifically identifies changes in fuel load or hazard beyond a sprinkler system&amp;#039;s original design basis. This creates a need to reassess the relationship between the hazard and its protection. The existence of installed equipment is not evidence that the current operation remains within its intended scope. &amp;lt;ref name=&amp;quot;FPH-22a95fc6&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l23&quot;&gt;Line 23:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 23:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== What the assessment has to establish ==&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== What the assessment has to establish ==&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;An assessment starts by identifying what could be harmed and how a fire could produce that harm. Life, property, continuity of operations, heritage and the environment can all be relevant. These objectives overlap, but they do not describe the same outcome. A building that allows everyone to escape can still suffer a loss that stops its activities. Equally, preserving the structure does not necessarily preserve its contents or services. Meacham&amp;#039;s account of building fire risk analysis makes these distinctions part of defining the problem. &amp;lt;ref name=&amp;quot;MEACHAM-3d03e7f5&amp;quot;&amp;gt;Meacham (2002), pp. 5-153–5-155.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;An assessment starts by identifying what could be harmed and how a fire could produce that harm. Life, property, continuity of operations, heritage and the environment can all be relevant. These objectives overlap, but they do not describe the same outcome. A building that allows everyone to escape can still suffer a loss that stops its activities. Equally, preserving the structure does not necessarily preserve its contents or services. Meacham&amp;#039;s account of building fire risk analysis makes these distinctions part of defining the problem. &amp;lt;ref name=&amp;quot;MEACHAM-3d03e7f5&amp;quot;&amp;gt;Meacham (2002), pp. 5-153–5-155.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[[File:fse-industrial_occupancy-v3.svg|thumb|upright=1.5|alt=Industrial occupancy: Life safety, Property, Continuity, Heritage, Environment|What the assessment has to establish for &lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;Industrial &lt;/del&gt;occupancy.]]&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[[File:fse-industrial_occupancy-v3.svg|thumb|upright=1.5|alt=Industrial occupancy: Life safety, Property, Continuity, Heritage, Environment|What the assessment has to establish for &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;an industrial &lt;/ins&gt;occupancy.]]&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;A hazard assessment then identifies possible ignition sources, combustible materials and the conditions through which fire could spread. The arrangement matters as well as the quantity of material. The description includes the building, its compartments and the protection systems that may affect the event. A hazard assessment asks what could happen under specified conditions. A risk assessment adds consideration of how likely those conditions and consequences are. A calculated consequence therefore does not, by itself, establish a probability of loss. &amp;lt;ref name=&amp;quot;MEACHAM-3d03e7f5&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;A hazard assessment then identifies possible ignition sources, combustible materials and the conditions through which fire could spread. The arrangement matters as well as the quantity of material. The description includes the building, its compartments and the protection systems that may affect the event. A hazard assessment asks what could happen under specified conditions. A risk assessment adds consideration of how likely those conditions and consequences are. A calculated consequence therefore does not, by itself, establish a probability of loss. &amp;lt;ref name=&amp;quot;MEACHAM-3d03e7f5&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;

&lt;!-- diff cache key firesb_pjbsiy42-wiki_:diff:1.41:old-7900:rev-9454:php=table --&gt;
&lt;/table&gt;</summary>
		<author><name>Peter</name></author>
	</entry>
	<entry>
		<id>https://fire-safety.academy/w/index.php?title=Industrial_occupancy&amp;diff=7900&amp;oldid=prev</id>
		<title>Daan: Add SVG figures fse-industrial_occupancy-v1.svg, fse-industrial_occupancy-v2.svg, fse-industrial_occupancy-v3.svg (list-7 visual plan)</title>
		<link rel="alternate" type="text/html" href="https://fire-safety.academy/w/index.php?title=Industrial_occupancy&amp;diff=7900&amp;oldid=prev"/>
		<updated>2026-11-13T08:15:47Z</updated>

		<summary type="html">&lt;p&gt;Add SVG figures fse-industrial_occupancy-v1.svg, fse-industrial_occupancy-v2.svg, fse-industrial_occupancy-v3.svg (list-7 visual plan)&lt;/p&gt;
&lt;table style=&quot;background-color: #fff; color: #202122;&quot; data-mw=&quot;interface&quot;&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;tr class=&quot;diff-title&quot; lang=&quot;en&quot;&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;← Older revision&lt;/td&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;Revision as of 09:15, 13 November 2026&lt;/td&gt;
				&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l5&quot;&gt;Line 5:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 5:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Processes and hazard identification ==&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Processes and hazard identification ==&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[[Sprinkler hazard classification]] concerns the fire challenge represented in a suppression design. [[Hazardous area classification]] addresses a different question concerning potentially hazardous atmospheres and equipment. Neither can be inferred completely from the word industrial. The handbook emphasises the diversity of fuels, processes and possible explosions within industrial facilities. The relevant classification needs the actual materials and operating conditions. &amp;lt;ref name=&amp;quot;FPH-22a95fc6&amp;quot;&amp;gt;Cote et al. (2008), §20.18, p. 20-204.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[[Sprinkler hazard classification]] concerns the fire challenge represented in a suppression design. [[Hazardous area classification]] addresses a different question concerning potentially hazardous atmospheres and equipment. Neither can be inferred completely from the word industrial. The handbook emphasises the diversity of fuels, processes and possible explosions within industrial facilities. The relevant classification needs the actual materials and operating conditions. &amp;lt;ref name=&amp;quot;FPH-22a95fc6&amp;quot;&amp;gt;Cote et al. (2008), §20.18, p. 20-204.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-deleted&quot;&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;[[File:fse-industrial_occupancy-v1.svg|thumb|upright=1.5|alt=Industrial occupancy: Material, Process, Ignition source, Possible consequence|Processes and hazard identification for Industrial occupancy.]]&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[[Ammonia refrigeration]] is one example of a specialised industrial system requiring its own hazard information. Its name does not provide the inventory, layout or release conditions needed for assessment. The broader method identifies equipment and materials before constructing incident scenarios. The same approach separates process-specific hazards from ordinary building hazards such as electrical equipment, heating and maintenance work. &amp;lt;ref name=&amp;quot;FPH-22a95fc6&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;MEACHAM-b6373d4d&amp;quot;&amp;gt;Meacham (2002), pp. 5-155–5-156.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[[Ammonia refrigeration]] is one example of a specialised industrial system requiring its own hazard information. Its name does not provide the inventory, layout or release conditions needed for assessment. The broader method identifies equipment and materials before constructing incident scenarios. The same approach separates process-specific hazards from ordinary building hazards such as electrical equipment, heating and maintenance work. &amp;lt;ref name=&amp;quot;FPH-22a95fc6&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;MEACHAM-b6373d4d&amp;quot;&amp;gt;Meacham (2002), pp. 5-155–5-156.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l12&quot;&gt;Line 12:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 13:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Movement, process change and preparedness ==&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Movement, process change and preparedness ==&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[[Common path of travel]] is one feature of the escape arrangement considered in industrial protection. The handbook identifies locked and obstructed exits among the contributors to serious losses. Route geometry and usable doors therefore need to be considered together. A route shown on a drawing provides little protection if operating practices prevent its use. &amp;lt;ref name=&amp;quot;FPH-2d7261ea&amp;quot;&amp;gt;Cote et al. (2008), §20.18, pp. 20-204, 20-209.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[[Common path of travel]] is one feature of the escape arrangement considered in industrial protection. The handbook identifies locked and obstructed exits among the contributors to serious losses. Route geometry and usable doors therefore need to be considered together. A route shown on a drawing provides little protection if operating practices prevent its use. &amp;lt;ref name=&amp;quot;FPH-2d7261ea&amp;quot;&amp;gt;Cote et al. (2008), §20.18, pp. 20-204, 20-209.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-deleted&quot;&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;[[File:fse-industrial_occupancy-v2.svg|thumb|upright=1.5|alt=Industrial occupancy: Changed process, Changed hazard, Protection review, Emergency roles|Movement, process change and preparedness for Industrial occupancy.]]&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;An [[Emergency action plan]] connects warning with actions such as evacuation, equipment shutdown and an authorised response. The handbook describes planning with the responding fire service and identifying hazardous materials on site plans. It also discusses exercises as a way to identify deficiencies. These activities make the plan a description of coordinated actions rather than a list of telephone numbers. &amp;lt;ref name=&amp;quot;FPH-b054bd8c&amp;quot;&amp;gt;Cote et al. (2008), §20.18, p. 20-209.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;An [[Emergency action plan]] connects warning with actions such as evacuation, equipment shutdown and an authorised response. The handbook describes planning with the responding fire service and identifying hazardous materials on site plans. It also discusses exercises as a way to identify deficiencies. These activities make the plan a description of coordinated actions rather than a list of telephone numbers. &amp;lt;ref name=&amp;quot;FPH-b054bd8c&amp;quot;&amp;gt;Cote et al. (2008), §20.18, p. 20-209.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l21&quot;&gt;Line 21:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 23:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== What the assessment has to establish ==&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== What the assessment has to establish ==&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;An assessment starts by identifying what could be harmed and how a fire could produce that harm. Life, property, continuity of operations, heritage and the environment can all be relevant. These objectives overlap, but they do not describe the same outcome. A building that allows everyone to escape can still suffer a loss that stops its activities. Equally, preserving the structure does not necessarily preserve its contents or services. Meacham&amp;#039;s account of building fire risk analysis makes these distinctions part of defining the problem. &amp;lt;ref name=&amp;quot;MEACHAM-3d03e7f5&amp;quot;&amp;gt;Meacham (2002), pp. 5-153–5-155.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;An assessment starts by identifying what could be harmed and how a fire could produce that harm. Life, property, continuity of operations, heritage and the environment can all be relevant. These objectives overlap, but they do not describe the same outcome. A building that allows everyone to escape can still suffer a loss that stops its activities. Equally, preserving the structure does not necessarily preserve its contents or services. Meacham&amp;#039;s account of building fire risk analysis makes these distinctions part of defining the problem. &amp;lt;ref name=&amp;quot;MEACHAM-3d03e7f5&amp;quot;&amp;gt;Meacham (2002), pp. 5-153–5-155.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-deleted&quot;&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;[[File:fse-industrial_occupancy-v3.svg|thumb|upright=1.5|alt=Industrial occupancy: Life safety, Property, Continuity, Heritage, Environment|What the assessment has to establish for Industrial occupancy.]]&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;A hazard assessment then identifies possible ignition sources, combustible materials and the conditions through which fire could spread. The arrangement matters as well as the quantity of material. The description includes the building, its compartments and the protection systems that may affect the event. A hazard assessment asks what could happen under specified conditions. A risk assessment adds consideration of how likely those conditions and consequences are. A calculated consequence therefore does not, by itself, establish a probability of loss. &amp;lt;ref name=&amp;quot;MEACHAM-3d03e7f5&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;A hazard assessment then identifies possible ignition sources, combustible materials and the conditions through which fire could spread. The arrangement matters as well as the quantity of material. The description includes the building, its compartments and the protection systems that may affect the event. A hazard assessment asks what could happen under specified conditions. A risk assessment adds consideration of how likely those conditions and consequences are. A calculated consequence therefore does not, by itself, establish a probability of loss. &amp;lt;ref name=&amp;quot;MEACHAM-3d03e7f5&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;

&lt;!-- diff cache key firesb_pjbsiy42-wiki_:diff:1.41:old-3721:rev-7900:php=table --&gt;
&lt;/table&gt;</summary>
		<author><name>Daan</name></author>
	</entry>
	<entry>
		<id>https://fire-safety.academy/w/index.php?title=Industrial_occupancy&amp;diff=3721&amp;oldid=prev</id>
		<title>Sanne: New FSE wiki article: Industrial occupancy (written by GPT-6)</title>
		<link rel="alternate" type="text/html" href="https://fire-safety.academy/w/index.php?title=Industrial_occupancy&amp;diff=3721&amp;oldid=prev"/>
		<updated>2026-11-07T21:35:08Z</updated>

		<summary type="html">&lt;p&gt;New FSE wiki article: Industrial occupancy (written by GPT-6)&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;An &amp;#039;&amp;#039;&amp;#039;industrial occupancy&amp;#039;&amp;#039;&amp;#039; is a building use involving manufacturing, processing or other industrial operations. The NFPA handbook describes a broad category ranging from facilities with many workers to equipment-intensive premises with few occupants. The materials and processes can create very different fire and explosion hazards within that category. &amp;lt;ref name=&amp;quot;FPH-2eeca0ba&amp;quot;&amp;gt;Cote et al. (2008), §20.18, pp. 20-203–20-204.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
The occupancy name is therefore only an initial description. The SFPE Handbook&amp;#039;s risk framework examines ignition sources, fuels, failure mechanisms and the resulting consequences. The industrial chapter similarly connects the available escape time with the contents, construction and protection systems. Life safety and property protection remain related but separate objectives. An operation with few employees can still create a severe loss exposure, while a crowded work area can require close attention to warning and usable escape routes. &amp;lt;ref name=&amp;quot;FPH-2eeca0ba&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;MEACHAM-ea1faa2f&amp;quot;&amp;gt;Meacham (2002), pp. 5-153–5-156.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== Processes and hazard identification ==&lt;br /&gt;
[[Sprinkler hazard classification]] concerns the fire challenge represented in a suppression design. [[Hazardous area classification]] addresses a different question concerning potentially hazardous atmospheres and equipment. Neither can be inferred completely from the word industrial. The handbook emphasises the diversity of fuels, processes and possible explosions within industrial facilities. The relevant classification needs the actual materials and operating conditions. &amp;lt;ref name=&amp;quot;FPH-22a95fc6&amp;quot;&amp;gt;Cote et al. (2008), §20.18, p. 20-204.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
[[Ammonia refrigeration]] is one example of a specialised industrial system requiring its own hazard information. Its name does not provide the inventory, layout or release conditions needed for assessment. The broader method identifies equipment and materials before constructing incident scenarios. The same approach separates process-specific hazards from ordinary building hazards such as electrical equipment, heating and maintenance work. &amp;lt;ref name=&amp;quot;FPH-22a95fc6&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;MEACHAM-b6373d4d&amp;quot;&amp;gt;Meacham (2002), pp. 5-155–5-156.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
The handbook identifies plant operators, plans, previous incidents and insurers as sources of assessment information. [[Fire insurance]] and organisations such as [[FM Global]] belong to the wider property-protection setting. Their evidence can contribute to understanding losses and protection, while the statutory framework establishes separate obligations. Information from one part of the system does not automatically settle every other question. &amp;lt;ref name=&amp;quot;FPH-22a95fc6&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;MEACHAM-ea1faa2f&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== Movement, process change and preparedness ==&lt;br /&gt;
[[Common path of travel]] is one feature of the escape arrangement considered in industrial protection. The handbook identifies locked and obstructed exits among the contributors to serious losses. Route geometry and usable doors therefore need to be considered together. A route shown on a drawing provides little protection if operating practices prevent its use. &amp;lt;ref name=&amp;quot;FPH-2d7261ea&amp;quot;&amp;gt;Cote et al. (2008), §20.18, pp. 20-204, 20-209.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
An [[Emergency action plan]] connects warning with actions such as evacuation, equipment shutdown and an authorised response. The handbook describes planning with the responding fire service and identifying hazardous materials on site plans. It also discusses exercises as a way to identify deficiencies. These activities make the plan a description of coordinated actions rather than a list of telephone numbers. &amp;lt;ref name=&amp;quot;FPH-b054bd8c&amp;quot;&amp;gt;Cote et al. (2008), §20.18, p. 20-209.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Changes in a process can alter the hazard without changing the building&amp;#039;s general occupancy. The handbook specifically identifies changes in fuel load or hazard beyond a sprinkler system&amp;#039;s original design basis. This creates a need to reassess the relationship between the hazard and its protection. The existence of installed equipment is not evidence that the current operation remains within its intended scope. &amp;lt;ref name=&amp;quot;FPH-22a95fc6&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
The roles assigned to employees also require a defined basis. The handbook distinguishes training for those expected to use firefighting equipment and wider preparations for evacuation. A person&amp;#039;s routine familiarity with production equipment does not establish competence in every emergency task. The planned role, available equipment and training need to be considered together. &amp;lt;ref name=&amp;quot;FPH-b054bd8c&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== What the assessment has to establish ==&lt;br /&gt;
An assessment starts by identifying what could be harmed and how a fire could produce that harm. Life, property, continuity of operations, heritage and the environment can all be relevant. These objectives overlap, but they do not describe the same outcome. A building that allows everyone to escape can still suffer a loss that stops its activities. Equally, preserving the structure does not necessarily preserve its contents or services. Meacham&amp;#039;s account of building fire risk analysis makes these distinctions part of defining the problem. &amp;lt;ref name=&amp;quot;MEACHAM-3d03e7f5&amp;quot;&amp;gt;Meacham (2002), pp. 5-153–5-155.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
A hazard assessment then identifies possible ignition sources, combustible materials and the conditions through which fire could spread. The arrangement matters as well as the quantity of material. The description includes the building, its compartments and the protection systems that may affect the event. A hazard assessment asks what could happen under specified conditions. A risk assessment adds consideration of how likely those conditions and consequences are. A calculated consequence therefore does not, by itself, establish a probability of loss. &amp;lt;ref name=&amp;quot;MEACHAM-3d03e7f5&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
The people affected need to be described with similar care. An occupancy name provides a useful starting point, but does not fully describe an individual&amp;#039;s ability to respond. The NFPA handbook treats occupancy classification as a substitute description for a collection of life safety characteristics. Detailed assessment needs more information when those characteristics determine the result. Age, mobility, awareness, familiarity and available assistance can change the protection that an occupant needs. A category suitable for organising code requirements is therefore not a complete prediction of an evacuation. &amp;lt;ref name=&amp;quot;FPH-5a916084&amp;quot;&amp;gt;Cote et al. (2008), §20.1, p. 20-9.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Different forms of evidence answer different questions. Inspection can identify an obstruction or an unprotected opening. A calculation can explore a fire scenario under stated assumptions. Historical records can indicate recurring causes or consequences. None of these sources removes the need to check whether the evidence applies to the particular building and activity. Meacham identifies changing materials, uncertain data and future changes in use as limitations when past experience informs a new assessment. &amp;lt;ref name=&amp;quot;MEACHAM-29bfd96c&amp;quot;&amp;gt;Meacham (2002), pp. 5-154–5-156.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Assessment also includes the behaviour of safeguards when conditions are unfavourable. A review can examine a failed component, an unavailable protection system or an action that does not occur as intended. Fault trees work backwards from an unwanted event towards possible causes. Event trees work forwards from an initiating event through possible outcomes. Their structure can clarify dependencies before reliable numerical probabilities are available. Assigning a number to each branch is a separate evidential step. &amp;lt;ref name=&amp;quot;MEACHAM-f72ba574&amp;quot;&amp;gt;Meacham (2002), p. 5-156.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
The resulting judgement depends on the purpose of the assessment and the acceptance criteria. A result that answers a narrow equipment question may leave wider building risks unresolved. Stakeholders can also value consequences differently, especially where life safety, economic loss and irreplaceable heritage are involved. Recording the scope makes the meaning of an acceptable result visible. It also identifies which changes in use, population or protection would require the assessment to be reconsidered. &amp;lt;ref name=&amp;quot;MEACHAM-3d03e7f5&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;IFEG-a681012e&amp;quot;&amp;gt;Australian Building Codes Board (2005), §1.2.4, pp. 1.2-6–1.2-7.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== Occupant response and escape ==&lt;br /&gt;
Escape involves more than movement through a doorway. An occupant must first receive or notice information, interpret it and decide what to do. These activities can take place before travel begins. Proulx distinguishes the delay before movement from the time spent moving towards safety. A calculation that represents only walking or flow therefore describes part of the evacuation process. Whether that part is sufficient for the question being studied depends on the stated scope of the analysis. &amp;lt;ref name=&amp;quot;PROULX-fd20bb69&amp;quot;&amp;gt;Proulx (2002), pp. 3-342, 3-347.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
The availability of an exit and its actual use are also different. Proulx reports that people may investigate ambiguous cues and favour familiar routes. The assumption that everyone immediately follows the nearest available escape route can therefore misrepresent response. Route familiarity, information and the actions of others affect how the physical escape system is used. The NFPA handbook makes a related distinction between egress adequacy and reliability. Capacity provides one part of the system; warning, marking, illumination and protection support its effective use. &amp;lt;ref name=&amp;quot;PROULX-88eb4f25&amp;quot;&amp;gt;Proulx (2002), p. 3-342.&amp;lt;/ref&amp;gt;&amp;lt;ref name=&amp;quot;FPH-1d934435&amp;quot;&amp;gt;Cote et al. (2008), §20.1, pp. 20-11–20-12.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Occupant characteristics determine whether an assumed response is plausible. The IFEG identifies state of alertness, mobility, hearing, vision and ability to understand instructions among the relevant characteristics. It separately identifies the help required and the help actually available. Staff numbers and shift patterns can therefore matter alongside the layout. Describing a population only by its total number omits information that can control evacuation performance. The relevant characteristics depend on the particular design question. &amp;lt;ref name=&amp;quot;IFEG-a681012e&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Smoke changes both the environment and the movement problem. It can obscure routes and lighting, reduce movement speed and expose occupants to harmful combustion products. Proulx describes occupants moving into smoke in real incidents, including situations where conditions changed after movement began. Such observations do not establish that travel through smoke is safe. They show why an escape assessment has to consider changing conditions along the route, rather than treating the destination alone as the point of concern. &amp;lt;ref name=&amp;quot;PROULX-a36dbc71&amp;quot;&amp;gt;Proulx (2002), p. 3-362.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Different times also describe different parts of the process. Flow time concerns how long a population takes to pass a particular element. Movement time concerns travel between locations. Total evacuation time includes delays and interactions beyond either of those measures. Treating these quantities as interchangeable can conceal a bottleneck or omit a period of exposure. Proulx&amp;#039;s timing framework connects the response sequence to the period during which the escape environment remains tenable, meaning tolerable for the people involved. &amp;lt;ref name=&amp;quot;PROULX-9d88c12d&amp;quot;&amp;gt;Proulx (2002), p. 3-347.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Protection of occupants can include controlling the fire, limiting smoke spread and supporting movement. The NFPA handbook presents prevention, management of fire and management of exposed occupants as related strategies. Their combination depends on the population and building. Where assistance is necessary, the assumed staff response becomes part of the safety system. Where an escape route is credited, its continuing usability matters. A description of the strategy therefore includes both physical features and the actions on which their effectiveness depends. &amp;lt;ref name=&amp;quot;FPH-d603624a&amp;quot;&amp;gt;Cote et al. (2008), §20.1, pp. 20-9–20-12.&amp;lt;/ref&amp;gt;&amp;lt;ref name=&amp;quot;IFEG-a681012e&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== Keeping the protection effective during use ==&lt;br /&gt;
The conditions recorded at design stage can change after a building opens. Contents, storage arrangements, activities and the population may differ from the original description. The NFPA handbook treats continued inspection as a means of checking that the occupancy and its protection remain consistent with the approved arrangements. This connects operational management with design assumptions. A protection measure that suited the original hazard may need reassessment when the hazard changes. The building&amp;#039;s outward appearance need not change for this issue to arise. &amp;lt;ref name=&amp;quot;FPH-664e7eb9&amp;quot;&amp;gt;Cote et al. (2008), §1.5, p. 1-84.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Inspection includes the escape system and the conditions that can lead to ignition or fire spread. The handbook identifies obstructed routes, accumulated combustible waste, storage practices, utilities and hazardous processes as matters for examination. Fire doors, exit signs and emergency lighting are also included. Looking at these features together connects prevention with the ability to respond if prevention fails. A check limited to visible extinguishers would leave substantial parts of the fire safety arrangement unexamined. &amp;lt;ref name=&amp;quot;FPH-664e7eb9&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Protection equipment requires its own evidence of continuing condition. Inspection can review whether alarms, pumps, sprinklers and other systems receive appropriate testing and maintenance. Records help establish what was examined and whether deficiencies remain. The handbook distinguishes installation inspections, continuing compliance inspections and follow-up visits. Each answers a different question about the life of the premises. The applicable frequency and authority for such work depend on the regulatory framework and the hazards involved. &amp;lt;ref name=&amp;quot;FPH-7c5133c9&amp;quot;&amp;gt;Cote et al. (2008), §1.5, pp. 1-84, 1-89.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
A record of a defect is different from a record that the defect was corrected. Follow-up closes that gap. The handbook emphasises reinspection after violations have been identified and notices issued. The property file can retain plans, specifications, permits, reports and correspondence so that later inspections have a reliable starting point. This history is also useful when changes in use or equipment are proposed. It links the observed conditions with the basis on which the building was previously assessed. &amp;lt;ref name=&amp;quot;FPH-7c5133c9&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Emergency procedures form another part of the operational system. Written arrangements describe responsibilities, but observation of a drill or exercise can reveal how those responsibilities work in practice. The handbook relates review of procedures to the occupancy and the protection features available. The IFEG adds that assistance available to occupants may vary between shifts. A procedure based on staffing that is absent during part of the operating day would describe different conditions from those actually present. &amp;lt;ref name=&amp;quot;FPH-664e7eb9&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;IFEG-220e690c&amp;quot;&amp;gt;Australian Building Codes Board (2005), §1.2.4, p. 1.2-6.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Management information also supports emergency responders. Construction, access, vertical openings, utilities and unusual hazards can be recorded during inspections and used in planning. That information serves a different purpose from merely recording a pass or fail against a checklist. It helps explain how an incident could develop and which features may assist or obstruct the response. Meacham notes that checklists are useful tools, but a narrow focus on their entries can obscure hazards outside the list. &amp;lt;ref name=&amp;quot;FPH-664e7eb9&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;MEACHAM-6039056e&amp;quot;&amp;gt;Meacham (2002), p. 5-155.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== Preparation, coordination and recovery ==&lt;br /&gt;
Emergency preparation starts by identifying the people, property, operations and environment that could be affected. The NFPA handbook connects this assessment with the resources needed to detect threats, warn people and stabilise an incident. A plan therefore describes more than the arrival of responders. It includes actions by the organisation itself and the conditions under which external assistance is required. The selected arrangements depend on the hazards and the consequences the programme is intended to control. &amp;lt;ref name=&amp;quot;FPH-44fccb20&amp;quot;&amp;gt;Cote et al. (2008), §1.8, p. 1-137.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Responsibilities extend across different parts of an organisation. Facilities, operations, security, health and safety, information technology and management may each control resources needed during an emergency. The handbook also identifies coordination with fire, police, medical services, public works and other external participants. Bringing those responsibilities together helps reveal dependencies before an incident occurs. A department&amp;#039;s individual plan can be internally clear while still conflicting with another department&amp;#039;s expected action. Coordination addresses that boundary. &amp;lt;ref name=&amp;quot;FPH-a76462df&amp;quot;&amp;gt;Cote et al. (2008), §1.8, p. 1-139.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Warning is a chain of actions rather than simply a sound. A threat has to be detected, relevant personnel notified and protective instructions communicated. The handbook discusses assigned operators, usable communication methods and messages that can be heard and understood. Rehearsal helps establish whether the people responsible can carry out those tasks. The communication arrangement is consequently assessed together with its intended audience and the actions expected after the message. &amp;lt;ref name=&amp;quot;FPH-48fc55ce&amp;quot;&amp;gt;Cote et al. (2008), §1.8, p. 1-147.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Training, drills and exercises provide different opportunities to develop and examine performance. Personnel need to understand their responsibilities, and leaders need to assess developing conditions and direct resources. The handbook treats periodic evaluation and updating as parts of the programme. Changes in hazards, staffing, facilities or contact arrangements can make an earlier plan less representative. Keeping the programme effective therefore involves maintaining organisational knowledge as well as maintaining equipment. &amp;lt;ref name=&amp;quot;FPH-c9a4e6dc&amp;quot;&amp;gt;Cote et al. (2008), §1.8, pp. 1-137, 1-139, 1-147.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Recovery raises questions that remain after immediate danger is controlled. Critical activities can depend on premises, data, utilities, suppliers and specialist staff. The handbook&amp;#039;s business impact analysis examines which functions are essential and what follows when they are unavailable. This can reveal losses that are not proportional to the visible physical damage. A small interruption at a critical point can affect the wider operation, while damaged nonessential space may have a different consequence. &amp;lt;ref name=&amp;quot;FPH-48fc55ce&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
The SFPE Handbook similarly distinguishes business continuity from the direct physical consequences of fire. Reputation, market position and prolonged disruption can matter alongside immediate repair costs. These objectives need to be identified explicitly because a strategy focused on evacuation may not address them. Preparation and recovery planning connect those objectives with responsibilities and resources. Their effectiveness remains dependent on realistic assumptions about what will be available during the event and throughout the period of restoration. &amp;lt;ref name=&amp;quot;MEACHAM-3d03e7f5&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;FPH-ec254854&amp;quot;&amp;gt;Cote et al. (2008), §1.8, pp. 1-137, 1-147.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== Notes ==&lt;br /&gt;
&amp;lt;references /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== References ==&lt;br /&gt;
* Australian Building Codes Board. (2005). &amp;#039;&amp;#039;International fire engineering guidelines&amp;#039;&amp;#039;.&lt;br /&gt;
* Cote, A. E., Grant, C. C., Hall, J. R., Jr., &amp;amp; Solomon, R. E. (Eds.). (2008). &amp;#039;&amp;#039;Fire protection handbook&amp;#039;&amp;#039; (20th ed.). National Fire Protection Association.&lt;br /&gt;
* Meacham, B. J. (2002). Building fire risk analysis. In P. J. DiNenno (Ed.), &amp;#039;&amp;#039;SFPE handbook of fire protection engineering&amp;#039;&amp;#039; (3rd ed., Section 5, Chapter 12, pp. 5-153–5-175). National Fire Protection Association.&lt;br /&gt;
* Proulx, G. (2002). Movement of people: The evacuation timing. In P. J. DiNenno (Ed.), &amp;#039;&amp;#039;SFPE handbook of fire protection engineering&amp;#039;&amp;#039; (3rd ed., Section 3, Chapter 13, pp. 3-342–3-366). National Fire Protection Association.&lt;br /&gt;
&lt;br /&gt;
[[Category:Special Hazards &amp;amp; Building Types]]&lt;/div&gt;</summary>
		<author><name>Sanne</name></author>
	</entry>
</feed>