<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://fire-safety.academy/w/index.php?action=history&amp;feed=atom&amp;title=Hydrogen_chloride</id>
	<title>Hydrogen chloride - Revision history</title>
	<link rel="self" type="application/atom+xml" href="https://fire-safety.academy/w/index.php?action=history&amp;feed=atom&amp;title=Hydrogen_chloride"/>
	<link rel="alternate" type="text/html" href="https://fire-safety.academy/w/index.php?title=Hydrogen_chloride&amp;action=history"/>
	<updated>2026-11-21T22:01:19Z</updated>
	<subtitle>Revision history for this page on the wiki</subtitle>
	<generator>MediaWiki 1.43.11</generator>
	<entry>
		<id>https://fire-safety.academy/w/index.php?title=Hydrogen_chloride&amp;diff=4850&amp;oldid=prev</id>
		<title>Linda: Remove bibliographic source lines from image captions and descriptions</title>
		<link rel="alternate" type="text/html" href="https://fire-safety.academy/w/index.php?title=Hydrogen_chloride&amp;diff=4850&amp;oldid=prev"/>
		<updated>2026-11-08T07:25:16Z</updated>

		<summary type="html">&lt;p&gt;Remove bibliographic source lines from image captions and descriptions&lt;/p&gt;
&lt;table style=&quot;background-color: #fff; color: #202122;&quot; data-mw=&quot;interface&quot;&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;tr class=&quot;diff-title&quot; lang=&quot;en&quot;&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;← Older revision&lt;/td&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;Revision as of 08:25, 8 November 2026&lt;/td&gt;
				&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l5&quot;&gt;Line 5:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 5:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Formation in heated materials ==&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Formation in heated materials ==&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Chlorine-bearing [[Plastics in fire]] can form HCl during pyrolysis, the thermal breakdown of a material. The halogen acids are formed even when that process does not lead to flaming combustion. Other halogen-bearing materials can form hydrogen bromide or [[Hydrogen fluoride]], and chlorine- or bromine-based fire retardants can add to the acid-gas yield.&amp;lt;ref name=&amp;quot;GB-13&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;GB-16&amp;quot; /&amp;gt; HCl is especially associated with [[Polyvinyl chloride]], whose chlorine is part of the polymer chain rather than merely an external contaminant.&amp;lt;ref name=&amp;quot;GB-13&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;BC-222&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Chlorine-bearing [[Plastics in fire]] can form HCl during pyrolysis, the thermal breakdown of a material. The halogen acids are formed even when that process does not lead to flaming combustion. Other halogen-bearing materials can form hydrogen bromide or [[Hydrogen fluoride]], and chlorine- or bromine-based fire retardants can add to the acid-gas yield.&amp;lt;ref name=&amp;quot;GB-13&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;GB-16&amp;quot; /&amp;gt; HCl is especially associated with [[Polyvinyl chloride]], whose chlorine is part of the polymer chain rather than merely an external contaminant.&amp;lt;ref name=&amp;quot;GB-13&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;BC-222&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[[File:fse-hydrogen-chloride-v1.svg|thumb|upright=1.5|alt=Flow diagram showing heated chlorine-bearing plastic releasing HCl, with some gas travelling in smoke and some depositing on surfaces|Heating chlorine-bearing plastic can release HCl before flaming; transport and deposition then separate generation from exposure&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;. Based on Gann and Bryner (2008), pp. 6-13 and 6-25&lt;/del&gt;.]]&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[[File:fse-hydrogen-chloride-v1.svg|thumb|upright=1.5|alt=Flow diagram showing heated chlorine-bearing plastic releasing HCl, with some gas travelling in smoke and some depositing on surfaces|Heating chlorine-bearing plastic can release HCl before flaming; transport and deposition then separate generation from exposure.]]&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The 2008 &amp;#039;&amp;#039;Fire Protection Handbook&amp;#039;&amp;#039; says that PVC readily evolves HCl at about 225–275 °C (437–527 °F).&amp;lt;ref name=&amp;quot;GB-13&amp;quot; /&amp;gt; Tewarson&amp;#039;s SFPE account reports that release can begin at temperatures as low as about 100 °C in particular tests, with HCl a major effluent up to about 200–220 °C.&amp;lt;ref name=&amp;quot;TE-138&amp;quot; /&amp;gt; These observations describe different materials and test conditions, so they should not be turned into a single universal onset temperature. A specimen may lose HCl before a large fraction of its carbon is consumed; the instantaneous HCl mass divided by the carbonaceous mass lost can therefore look unusually high early in decomposition.&amp;lt;ref name=&amp;quot;GB-13&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The 2008 &amp;#039;&amp;#039;Fire Protection Handbook&amp;#039;&amp;#039; says that PVC readily evolves HCl at about 225–275 °C (437–527 °F).&amp;lt;ref name=&amp;quot;GB-13&amp;quot; /&amp;gt; Tewarson&amp;#039;s SFPE account reports that release can begin at temperatures as low as about 100 °C in particular tests, with HCl a major effluent up to about 200–220 °C.&amp;lt;ref name=&amp;quot;TE-138&amp;quot; /&amp;gt; These observations describe different materials and test conditions, so they should not be turned into a single universal onset temperature. A specimen may lose HCl before a large fraction of its carbon is consumed; the instantaneous HCl mass divided by the carbonaceous mass lost can therefore look unusually high early in decomposition.&amp;lt;ref name=&amp;quot;GB-13&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l17&quot;&gt;Line 17:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 17:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The same table reports 0.480 g/g for that sheet in an inert atmosphere, 0.263 g/g for one PVC cable in air, and 0.117 g/g for one PVC–plasticiser–calcium carbonate mixture in nitrogen.&amp;lt;ref name=&amp;quot;TE-139&amp;quot; /&amp;gt; These values come from different formulations and conditions. They demonstrate why a single generic yield should not be assigned to every product bearing the PVC name. The table also shows that adding acid neutraliser and changing the proportions of PVC and plasticiser alter the measured release; it does not isolate any one change as the sole cause.&amp;lt;ref name=&amp;quot;TE-139&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The same table reports 0.480 g/g for that sheet in an inert atmosphere, 0.263 g/g for one PVC cable in air, and 0.117 g/g for one PVC–plasticiser–calcium carbonate mixture in nitrogen.&amp;lt;ref name=&amp;quot;TE-139&amp;quot; /&amp;gt; These values come from different formulations and conditions. They demonstrate why a single generic yield should not be assigned to every product bearing the PVC name. The table also shows that adding acid neutraliser and changing the proportions of PVC and plasticiser alter the measured release; it does not isolate any one change as the sole cause.&amp;lt;ref name=&amp;quot;TE-139&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[[File:fse-hydrogen-chloride-v2.svg|thumb|upright=1.5|alt=Three horizontal bars for HCl yields from different PVC specimens, labelled with each formulation and test atmosphere|Selected PVC specimens gave different HCl yields in the reported tests&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;. Based on Tewarson (2002), p. 3-139&lt;/del&gt;.]]&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[[File:fse-hydrogen-chloride-v2.svg|thumb|upright=1.5|alt=Three horizontal bars for HCl yields from different PVC specimens, labelled with each formulation and test atmosphere|Selected PVC specimens gave different HCl yields in the reported tests.]]&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The apparent yield can vary over the course of a test. Early HCl release may precede much of the material&amp;#039;s other mass loss, while later products include carbon monoxide and organic compounds.&amp;lt;ref name=&amp;quot;GB-13&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;TE-138&amp;quot; /&amp;gt; The yields in Tewarson&amp;#039;s table are reported as grams of HCl per gram of tested material. They must be kept separate from a room concentration, which depends on release rate, ventilation, mixing and removal.&amp;lt;ref name=&amp;quot;TE-139&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;GB-24&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;GB-25&amp;quot; /&amp;gt; For this reason, a material balance by itself does not show what an occupant breathes along an escape route.&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The apparent yield can vary over the course of a test. Early HCl release may precede much of the material&amp;#039;s other mass loss, while later products include carbon monoxide and organic compounds.&amp;lt;ref name=&amp;quot;GB-13&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;TE-138&amp;quot; /&amp;gt; The yields in Tewarson&amp;#039;s table are reported as grams of HCl per gram of tested material. They must be kept separate from a room concentration, which depends on release rate, ventilation, mixing and removal.&amp;lt;ref name=&amp;quot;TE-139&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;GB-24&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;GB-25&amp;quot; /&amp;gt; For this reason, a material balance by itself does not show what an occupant breathes along an escape route.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l23&quot;&gt;Line 23:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 23:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Effects on people ==&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Effects on people ==&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;HCl is both a sensory and a pulmonary [[Irritant gas]]. It can stimulate the eyes, nose, mouth and throat almost immediately. The handbook describes pain, blinking, tearing and mucus production; shutting the eyes can briefly relieve pain while making wayfinding harder.&amp;lt;ref name=&amp;quot;GB-16&amp;quot; /&amp;gt; A person may also cough or experience bronchoconstriction as HCl reaches the lungs. High exposures can lead to inflammation, pulmonary oedema and death, usually 6–48 hours after exposure in the account given by Gann and Bryner.&amp;lt;ref name=&amp;quot;GB-16&amp;quot; /&amp;gt; The delayed effect is one reason that an ability to keep moving during exposure does not establish that the exposure was harmless.&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;HCl is both a sensory and a pulmonary [[Irritant gas]]. It can stimulate the eyes, nose, mouth and throat almost immediately. The handbook describes pain, blinking, tearing and mucus production; shutting the eyes can briefly relieve pain while making wayfinding harder.&amp;lt;ref name=&amp;quot;GB-16&amp;quot; /&amp;gt; A person may also cough or experience bronchoconstriction as HCl reaches the lungs. High exposures can lead to inflammation, pulmonary oedema and death, usually 6–48 hours after exposure in the account given by Gann and Bryner.&amp;lt;ref name=&amp;quot;GB-16&amp;quot; /&amp;gt; The delayed effect is one reason that an ability to keep moving during exposure does not establish that the exposure was harmless.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[[File:fse-hydrogen-chloride-v3.svg|thumb|upright=1.5|alt=Two-path timeline showing immediate eye and airway irritation and possible later lung inflammation after high HCl exposure|HCl can impair escape promptly and may cause delayed lung injury after high exposure&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;. Based on Gann and Bryner (2008), p. 6-16&lt;/del&gt;.]]&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[[File:fse-hydrogen-chloride-v3.svg|thumb|upright=1.5|alt=Two-path timeline showing immediate eye and airway irritation and possible later lung inflammation after high HCl exposure|HCl can impair escape promptly and may cause delayed lung injury after high exposure.]]&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The handbook describes 75–100 µL/L as extremely irritating to the eyes and upper airway, with possible interference with physical activity needed for escape. For gas volume fractions, 1 µL/L is numerically equal to 1 part per million by volume (ppm).&amp;lt;ref name=&amp;quot;GB-16&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;GB-14&amp;quot;&amp;gt;Gann and Bryner (2008), p. 6-14.&amp;lt;/ref&amp;gt; Purser gives 50–100 ppm as strongly irritating in the human reports he reviews, and describes about 100–500 ppm as potentially slowing escape.&amp;lt;ref name=&amp;quot;PU-115&amp;quot;&amp;gt;Purser (2002), p. 2-115.&amp;lt;/ref&amp;gt;&amp;lt;ref name=&amp;quot;PU-119&amp;quot;&amp;gt;Purser (2002), p. 2-119.&amp;lt;/ref&amp;gt; Those are observations and expert interpretations with different exposure conditions, not a sharp boundary between safe and unsafe air.&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The handbook describes 75–100 µL/L as extremely irritating to the eyes and upper airway, with possible interference with physical activity needed for escape. For gas volume fractions, 1 µL/L is numerically equal to 1 part per million by volume (ppm).&amp;lt;ref name=&amp;quot;GB-16&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;GB-14&amp;quot;&amp;gt;Gann and Bryner (2008), p. 6-14.&amp;lt;/ref&amp;gt; Purser gives 50–100 ppm as strongly irritating in the human reports he reviews, and describes about 100–500 ppm as potentially slowing escape.&amp;lt;ref name=&amp;quot;PU-115&amp;quot;&amp;gt;Purser (2002), p. 2-115.&amp;lt;/ref&amp;gt;&amp;lt;ref name=&amp;quot;PU-119&amp;quot;&amp;gt;Purser (2002), p. 2-119.&amp;lt;/ref&amp;gt; Those are observations and expert interpretations with different exposure conditions, not a sharp boundary between safe and unsafe air.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l52&quot;&gt;Line 52:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 52:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The value of 1,000 µL/L should not be confused with every other HCl criterion. Purser&amp;#039;s 2002 SFPE chapter estimates that 200 ppm would impair escape in half the population and 900 ppm would incapacitate half. His first value concerns impaired movement; the second is a more severe endpoint.&amp;lt;ref name=&amp;quot;PU-121&amp;quot;&amp;gt;Purser (2002), p. 2-121.&amp;lt;/ref&amp;gt; The handbook&amp;#039;s 1,000 µL/L is a separate ISO-based incapacitation estimate, rather than a revision of Purser&amp;#039;s 200 ppm value.&amp;lt;ref name=&amp;quot;GB-16&amp;quot; /&amp;gt; The inputs differ in endpoint and judgement, even though both are used to discuss escape in a fire.&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The value of 1,000 µL/L should not be confused with every other HCl criterion. Purser&amp;#039;s 2002 SFPE chapter estimates that 200 ppm would impair escape in half the population and 900 ppm would incapacitate half. His first value concerns impaired movement; the second is a more severe endpoint.&amp;lt;ref name=&amp;quot;PU-121&amp;quot;&amp;gt;Purser (2002), p. 2-121.&amp;lt;/ref&amp;gt; The handbook&amp;#039;s 1,000 µL/L is a separate ISO-based incapacitation estimate, rather than a revision of Purser&amp;#039;s 200 ppm value.&amp;lt;ref name=&amp;quot;GB-16&amp;quot; /&amp;gt; The inputs differ in endpoint and judgement, even though both are used to discuss escape in a fire.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[[File:fse-hydrogen-chloride-v4.svg|thumb|upright=1.5|alt=Logarithmic HCl concentration scale marking 75 to 100 microlitres per litre irritation, and separate 200, 900 and 1000 escape criteria|Published HCl values refer to different irritation and escape endpoints&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;. Based on Gann and Bryner (2008), p. 6-16 and Purser (2002), p. 2-121&lt;/del&gt;.]]&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[[File:fse-hydrogen-chloride-v4.svg|thumb|upright=1.5|alt=Logarithmic HCl concentration scale marking 75 to 100 microlitres per litre irritation, and separate 200, 900 and 1000 escape criteria|Published HCl values refer to different irritation and escape endpoints.]]&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;For more sensitive people, a criterion of FEC = 1 is insufficient as a guarantee. The 2008 handbook&amp;#039;s illustrative susceptibility distribution associates FEC = 0.3 with 11.4 % of the population still susceptible to incapacitation at lower exposures and says no numerical criterion protects everybody.&amp;lt;ref name=&amp;quot;GB-25&amp;quot; /&amp;gt; Purser also proposes a 0.3 factor for escape impairment, but against his own 200 ppm reference and for a different outcome.&amp;lt;ref name=&amp;quot;PU-121&amp;quot; /&amp;gt; A workplace exposure limit or a one-hour emergency-planning level has yet another purpose; the handbook explicitly warns that occupational long-term limits are normally of little use for short, high fire exposures.&amp;lt;ref name=&amp;quot;GB-14&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;PU-121&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;For more sensitive people, a criterion of FEC = 1 is insufficient as a guarantee. The 2008 handbook&amp;#039;s illustrative susceptibility distribution associates FEC = 0.3 with 11.4 % of the population still susceptible to incapacitation at lower exposures and says no numerical criterion protects everybody.&amp;lt;ref name=&amp;quot;GB-25&amp;quot; /&amp;gt; Purser also proposes a 0.3 factor for escape impairment, but against his own 200 ppm reference and for a different outcome.&amp;lt;ref name=&amp;quot;PU-121&amp;quot; /&amp;gt; A workplace exposure limit or a one-hour emergency-planning level has yet another purpose; the handbook explicitly warns that occupational long-term limits are normally of little use for short, high fire exposures.&amp;lt;ref name=&amp;quot;GB-14&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;PU-121&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;

&lt;!-- diff cache key firesb_pjbsiy42-wiki_:diff:1.41:old-4802:rev-4850:php=table --&gt;
&lt;/table&gt;</summary>
		<author><name>Linda</name></author>
	</entry>
	<entry>
		<id>https://fire-safety.academy/w/index.php?title=Hydrogen_chloride&amp;diff=4802&amp;oldid=prev</id>
		<title>Lisa: Add 4 watermarked NFPA SVG illustrations</title>
		<link rel="alternate" type="text/html" href="https://fire-safety.academy/w/index.php?title=Hydrogen_chloride&amp;diff=4802&amp;oldid=prev"/>
		<updated>2026-11-08T07:22:01Z</updated>

		<summary type="html">&lt;p&gt;Add 4 watermarked NFPA SVG illustrations&lt;/p&gt;
&lt;table style=&quot;background-color: #fff; color: #202122;&quot; data-mw=&quot;interface&quot;&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;tr class=&quot;diff-title&quot; lang=&quot;en&quot;&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;← Older revision&lt;/td&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;Revision as of 08:22, 8 November 2026&lt;/td&gt;
				&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l5&quot;&gt;Line 5:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 5:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Formation in heated materials ==&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Formation in heated materials ==&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Chlorine-bearing [[Plastics in fire]] can form HCl during pyrolysis, the thermal breakdown of a material. The halogen acids are formed even when that process does not lead to flaming combustion. Other halogen-bearing materials can form hydrogen bromide or [[Hydrogen fluoride]], and chlorine- or bromine-based fire retardants can add to the acid-gas yield.&amp;lt;ref name=&amp;quot;GB-13&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;GB-16&amp;quot; /&amp;gt; HCl is especially associated with [[Polyvinyl chloride]], whose chlorine is part of the polymer chain rather than merely an external contaminant.&amp;lt;ref name=&amp;quot;GB-13&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;BC-222&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Chlorine-bearing [[Plastics in fire]] can form HCl during pyrolysis, the thermal breakdown of a material. The halogen acids are formed even when that process does not lead to flaming combustion. Other halogen-bearing materials can form hydrogen bromide or [[Hydrogen fluoride]], and chlorine- or bromine-based fire retardants can add to the acid-gas yield.&amp;lt;ref name=&amp;quot;GB-13&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;GB-16&amp;quot; /&amp;gt; HCl is especially associated with [[Polyvinyl chloride]], whose chlorine is part of the polymer chain rather than merely an external contaminant.&amp;lt;ref name=&amp;quot;GB-13&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;BC-222&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-deleted&quot;&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;[[File:fse-hydrogen-chloride-v1.svg|thumb|upright=1.5|alt=Flow diagram showing heated chlorine-bearing plastic releasing HCl, with some gas travelling in smoke and some depositing on surfaces|Heating chlorine-bearing plastic can release HCl before flaming; transport and deposition then separate generation from exposure. Based on Gann and Bryner (2008), pp. 6-13 and 6-25.]]&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The 2008 &amp;#039;&amp;#039;Fire Protection Handbook&amp;#039;&amp;#039; says that PVC readily evolves HCl at about 225–275 °C (437–527 °F).&amp;lt;ref name=&amp;quot;GB-13&amp;quot; /&amp;gt; Tewarson&amp;#039;s SFPE account reports that release can begin at temperatures as low as about 100 °C in particular tests, with HCl a major effluent up to about 200–220 °C.&amp;lt;ref name=&amp;quot;TE-138&amp;quot; /&amp;gt; These observations describe different materials and test conditions, so they should not be turned into a single universal onset temperature. A specimen may lose HCl before a large fraction of its carbon is consumed; the instantaneous HCl mass divided by the carbonaceous mass lost can therefore look unusually high early in decomposition.&amp;lt;ref name=&amp;quot;GB-13&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The 2008 &amp;#039;&amp;#039;Fire Protection Handbook&amp;#039;&amp;#039; says that PVC readily evolves HCl at about 225–275 °C (437–527 °F).&amp;lt;ref name=&amp;quot;GB-13&amp;quot; /&amp;gt; Tewarson&amp;#039;s SFPE account reports that release can begin at temperatures as low as about 100 °C in particular tests, with HCl a major effluent up to about 200–220 °C.&amp;lt;ref name=&amp;quot;TE-138&amp;quot; /&amp;gt; These observations describe different materials and test conditions, so they should not be turned into a single universal onset temperature. A specimen may lose HCl before a large fraction of its carbon is consumed; the instantaneous HCl mass divided by the carbonaceous mass lost can therefore look unusually high early in decomposition.&amp;lt;ref name=&amp;quot;GB-13&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l16&quot;&gt;Line 16:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 17:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The same table reports 0.480 g/g for that sheet in an inert atmosphere, 0.263 g/g for one PVC cable in air, and 0.117 g/g for one PVC–plasticiser–calcium carbonate mixture in nitrogen.&amp;lt;ref name=&amp;quot;TE-139&amp;quot; /&amp;gt; These values come from different formulations and conditions. They demonstrate why a single generic yield should not be assigned to every product bearing the PVC name. The table also shows that adding acid neutraliser and changing the proportions of PVC and plasticiser alter the measured release; it does not isolate any one change as the sole cause.&amp;lt;ref name=&amp;quot;TE-139&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The same table reports 0.480 g/g for that sheet in an inert atmosphere, 0.263 g/g for one PVC cable in air, and 0.117 g/g for one PVC–plasticiser–calcium carbonate mixture in nitrogen.&amp;lt;ref name=&amp;quot;TE-139&amp;quot; /&amp;gt; These values come from different formulations and conditions. They demonstrate why a single generic yield should not be assigned to every product bearing the PVC name. The table also shows that adding acid neutraliser and changing the proportions of PVC and plasticiser alter the measured release; it does not isolate any one change as the sole cause.&amp;lt;ref name=&amp;quot;TE-139&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-deleted&quot;&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;[[File:fse-hydrogen-chloride-v2.svg|thumb|upright=1.5|alt=Three horizontal bars for HCl yields from different PVC specimens, labelled with each formulation and test atmosphere|Selected PVC specimens gave different HCl yields in the reported tests. Based on Tewarson (2002), p. 3-139.]]&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The apparent yield can vary over the course of a test. Early HCl release may precede much of the material&amp;#039;s other mass loss, while later products include carbon monoxide and organic compounds.&amp;lt;ref name=&amp;quot;GB-13&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;TE-138&amp;quot; /&amp;gt; The yields in Tewarson&amp;#039;s table are reported as grams of HCl per gram of tested material. They must be kept separate from a room concentration, which depends on release rate, ventilation, mixing and removal.&amp;lt;ref name=&amp;quot;TE-139&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;GB-24&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;GB-25&amp;quot; /&amp;gt; For this reason, a material balance by itself does not show what an occupant breathes along an escape route.&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The apparent yield can vary over the course of a test. Early HCl release may precede much of the material&amp;#039;s other mass loss, while later products include carbon monoxide and organic compounds.&amp;lt;ref name=&amp;quot;GB-13&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;TE-138&amp;quot; /&amp;gt; The yields in Tewarson&amp;#039;s table are reported as grams of HCl per gram of tested material. They must be kept separate from a room concentration, which depends on release rate, ventilation, mixing and removal.&amp;lt;ref name=&amp;quot;TE-139&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;GB-24&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;GB-25&amp;quot; /&amp;gt; For this reason, a material balance by itself does not show what an occupant breathes along an escape route.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l21&quot;&gt;Line 21:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 23:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Effects on people ==&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Effects on people ==&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;HCl is both a sensory and a pulmonary [[Irritant gas]]. It can stimulate the eyes, nose, mouth and throat almost immediately. The handbook describes pain, blinking, tearing and mucus production; shutting the eyes can briefly relieve pain while making wayfinding harder.&amp;lt;ref name=&amp;quot;GB-16&amp;quot; /&amp;gt; A person may also cough or experience bronchoconstriction as HCl reaches the lungs. High exposures can lead to inflammation, pulmonary oedema and death, usually 6–48 hours after exposure in the account given by Gann and Bryner.&amp;lt;ref name=&amp;quot;GB-16&amp;quot; /&amp;gt; The delayed effect is one reason that an ability to keep moving during exposure does not establish that the exposure was harmless.&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;HCl is both a sensory and a pulmonary [[Irritant gas]]. It can stimulate the eyes, nose, mouth and throat almost immediately. The handbook describes pain, blinking, tearing and mucus production; shutting the eyes can briefly relieve pain while making wayfinding harder.&amp;lt;ref name=&amp;quot;GB-16&amp;quot; /&amp;gt; A person may also cough or experience bronchoconstriction as HCl reaches the lungs. High exposures can lead to inflammation, pulmonary oedema and death, usually 6–48 hours after exposure in the account given by Gann and Bryner.&amp;lt;ref name=&amp;quot;GB-16&amp;quot; /&amp;gt; The delayed effect is one reason that an ability to keep moving during exposure does not establish that the exposure was harmless.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-deleted&quot;&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;[[File:fse-hydrogen-chloride-v3.svg|thumb|upright=1.5|alt=Two-path timeline showing immediate eye and airway irritation and possible later lung inflammation after high HCl exposure|HCl can impair escape promptly and may cause delayed lung injury after high exposure. Based on Gann and Bryner (2008), p. 6-16.]]&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The handbook describes 75–100 µL/L as extremely irritating to the eyes and upper airway, with possible interference with physical activity needed for escape. For gas volume fractions, 1 µL/L is numerically equal to 1 part per million by volume (ppm).&amp;lt;ref name=&amp;quot;GB-16&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;GB-14&amp;quot;&amp;gt;Gann and Bryner (2008), p. 6-14.&amp;lt;/ref&amp;gt; Purser gives 50–100 ppm as strongly irritating in the human reports he reviews, and describes about 100–500 ppm as potentially slowing escape.&amp;lt;ref name=&amp;quot;PU-115&amp;quot;&amp;gt;Purser (2002), p. 2-115.&amp;lt;/ref&amp;gt;&amp;lt;ref name=&amp;quot;PU-119&amp;quot;&amp;gt;Purser (2002), p. 2-119.&amp;lt;/ref&amp;gt; Those are observations and expert interpretations with different exposure conditions, not a sharp boundary between safe and unsafe air.&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The handbook describes 75–100 µL/L as extremely irritating to the eyes and upper airway, with possible interference with physical activity needed for escape. For gas volume fractions, 1 µL/L is numerically equal to 1 part per million by volume (ppm).&amp;lt;ref name=&amp;quot;GB-16&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;GB-14&amp;quot;&amp;gt;Gann and Bryner (2008), p. 6-14.&amp;lt;/ref&amp;gt; Purser gives 50–100 ppm as strongly irritating in the human reports he reviews, and describes about 100–500 ppm as potentially slowing escape.&amp;lt;ref name=&amp;quot;PU-115&amp;quot;&amp;gt;Purser (2002), p. 2-115.&amp;lt;/ref&amp;gt;&amp;lt;ref name=&amp;quot;PU-119&amp;quot;&amp;gt;Purser (2002), p. 2-119.&amp;lt;/ref&amp;gt; Those are observations and expert interpretations with different exposure conditions, not a sharp boundary between safe and unsafe air.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l49&quot;&gt;Line 49:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 52:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The value of 1,000 µL/L should not be confused with every other HCl criterion. Purser&amp;#039;s 2002 SFPE chapter estimates that 200 ppm would impair escape in half the population and 900 ppm would incapacitate half. His first value concerns impaired movement; the second is a more severe endpoint.&amp;lt;ref name=&amp;quot;PU-121&amp;quot;&amp;gt;Purser (2002), p. 2-121.&amp;lt;/ref&amp;gt; The handbook&amp;#039;s 1,000 µL/L is a separate ISO-based incapacitation estimate, rather than a revision of Purser&amp;#039;s 200 ppm value.&amp;lt;ref name=&amp;quot;GB-16&amp;quot; /&amp;gt; The inputs differ in endpoint and judgement, even though both are used to discuss escape in a fire.&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The value of 1,000 µL/L should not be confused with every other HCl criterion. Purser&amp;#039;s 2002 SFPE chapter estimates that 200 ppm would impair escape in half the population and 900 ppm would incapacitate half. His first value concerns impaired movement; the second is a more severe endpoint.&amp;lt;ref name=&amp;quot;PU-121&amp;quot;&amp;gt;Purser (2002), p. 2-121.&amp;lt;/ref&amp;gt; The handbook&amp;#039;s 1,000 µL/L is a separate ISO-based incapacitation estimate, rather than a revision of Purser&amp;#039;s 200 ppm value.&amp;lt;ref name=&amp;quot;GB-16&amp;quot; /&amp;gt; The inputs differ in endpoint and judgement, even though both are used to discuss escape in a fire.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-deleted&quot;&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;[[File:fse-hydrogen-chloride-v4.svg|thumb|upright=1.5|alt=Logarithmic HCl concentration scale marking 75 to 100 microlitres per litre irritation, and separate 200, 900 and 1000 escape criteria|Published HCl values refer to different irritation and escape endpoints. Based on Gann and Bryner (2008), p. 6-16 and Purser (2002), p. 2-121.]]&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;For more sensitive people, a criterion of FEC = 1 is insufficient as a guarantee. The 2008 handbook&amp;#039;s illustrative susceptibility distribution associates FEC = 0.3 with 11.4 % of the population still susceptible to incapacitation at lower exposures and says no numerical criterion protects everybody.&amp;lt;ref name=&amp;quot;GB-25&amp;quot; /&amp;gt; Purser also proposes a 0.3 factor for escape impairment, but against his own 200 ppm reference and for a different outcome.&amp;lt;ref name=&amp;quot;PU-121&amp;quot; /&amp;gt; A workplace exposure limit or a one-hour emergency-planning level has yet another purpose; the handbook explicitly warns that occupational long-term limits are normally of little use for short, high fire exposures.&amp;lt;ref name=&amp;quot;GB-14&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;PU-121&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;For more sensitive people, a criterion of FEC = 1 is insufficient as a guarantee. The 2008 handbook&amp;#039;s illustrative susceptibility distribution associates FEC = 0.3 with 11.4 % of the population still susceptible to incapacitation at lower exposures and says no numerical criterion protects everybody.&amp;lt;ref name=&amp;quot;GB-25&amp;quot; /&amp;gt; Purser also proposes a 0.3 factor for escape impairment, but against his own 200 ppm reference and for a different outcome.&amp;lt;ref name=&amp;quot;PU-121&amp;quot; /&amp;gt; A workplace exposure limit or a one-hour emergency-planning level has yet another purpose; the handbook explicitly warns that occupational long-term limits are normally of little use for short, high fire exposures.&amp;lt;ref name=&amp;quot;GB-14&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;PU-121&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;

&lt;!-- diff cache key firesb_pjbsiy42-wiki_:diff:1.41:old-4390:rev-4802:php=table --&gt;
&lt;/table&gt;</summary>
		<author><name>Lisa</name></author>
	</entry>
	<entry>
		<id>https://fire-safety.academy/w/index.php?title=Hydrogen_chloride&amp;diff=4390&amp;oldid=prev</id>
		<title>Peter: New FSE wiki article: Hydrogen chloride (written by GPT-6)</title>
		<link rel="alternate" type="text/html" href="https://fire-safety.academy/w/index.php?title=Hydrogen_chloride&amp;diff=4390&amp;oldid=prev"/>
		<updated>2026-11-08T03:55:37Z</updated>

		<summary type="html">&lt;p&gt;New FSE wiki article: Hydrogen chloride (written by GPT-6)&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;&amp;#039;&amp;#039;&amp;#039;Hydrogen chloride&amp;#039;&amp;#039;&amp;#039; (&amp;#039;&amp;#039;&amp;#039;HCl&amp;#039;&amp;#039;&amp;#039;) is an acid gas that can be released when chlorine-containing materials are heated in a fire. Polyvinyl chloride (PVC), used in products including wiring, flooring and pipework, is a major source. HCl can appear during thermal decomposition before flames develop, so its presence cannot be inferred from flaming alone.&amp;lt;ref name=&amp;quot;GB-13&amp;quot;&amp;gt;Gann and Bryner (2008), p. 6-13.&amp;lt;/ref&amp;gt;&amp;lt;ref name=&amp;quot;BC-222&amp;quot;&amp;gt;Benedetti and Colonna (2008), p. 6-222.&amp;lt;/ref&amp;gt; It is a strong irritant to the eyes and airways. The pain, tearing and breathing difficulty can impede escape, while a sufficiently high inhaled dose can injure the lungs after the exposure has ended.&amp;lt;ref name=&amp;quot;GB-16&amp;quot;&amp;gt;Gann and Bryner (2008), p. 6-16.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
In [[Fire toxicity]] assessment, HCl has two distinct roles. Its immediate sensory effects are assessed against the concentration in the breathing zone, whereas serious lung injury depends on both concentration and duration.&amp;lt;ref name=&amp;quot;GB-16&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;GB-24&amp;quot;&amp;gt;Gann and Bryner (2008), p. 6-24.&amp;lt;/ref&amp;gt; The gas also deposits on wet or adsorptive surfaces. This can reduce the airborne concentration away from the fire, but creates a separate problem of chloride contamination and corrosion of equipment.&amp;lt;ref name=&amp;quot;GB-13&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;TE-138&amp;quot;&amp;gt;Tewarson (2002), p. 3-138.&amp;lt;/ref&amp;gt; Consequently, the HCl yield of a material, the concentration a person breathes and the contamination left on a surface are different quantities.&lt;br /&gt;
&lt;br /&gt;
== Formation in heated materials ==&lt;br /&gt;
Chlorine-bearing [[Plastics in fire]] can form HCl during pyrolysis, the thermal breakdown of a material. The halogen acids are formed even when that process does not lead to flaming combustion. Other halogen-bearing materials can form hydrogen bromide or [[Hydrogen fluoride]], and chlorine- or bromine-based fire retardants can add to the acid-gas yield.&amp;lt;ref name=&amp;quot;GB-13&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;GB-16&amp;quot; /&amp;gt; HCl is especially associated with [[Polyvinyl chloride]], whose chlorine is part of the polymer chain rather than merely an external contaminant.&amp;lt;ref name=&amp;quot;GB-13&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;BC-222&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
The 2008 &amp;#039;&amp;#039;Fire Protection Handbook&amp;#039;&amp;#039; says that PVC readily evolves HCl at about 225–275 °C (437–527 °F).&amp;lt;ref name=&amp;quot;GB-13&amp;quot; /&amp;gt; Tewarson&amp;#039;s SFPE account reports that release can begin at temperatures as low as about 100 °C in particular tests, with HCl a major effluent up to about 200–220 °C.&amp;lt;ref name=&amp;quot;TE-138&amp;quot; /&amp;gt; These observations describe different materials and test conditions, so they should not be turned into a single universal onset temperature. A specimen may lose HCl before a large fraction of its carbon is consumed; the instantaneous HCl mass divided by the carbonaceous mass lost can therefore look unusually high early in decomposition.&amp;lt;ref name=&amp;quot;GB-13&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
PVC products vary widely. The NFPA chapter describes hundreds of rigid and plasticised formulations, and says that most of the chlorine in PVC is released as HCl. Plasticisers and other additions affect fire behaviour, so building products should be tested in the form in which they are used.&amp;lt;ref name=&amp;quot;BC-222&amp;quot; /&amp;gt; Tewarson&amp;#039;s tests show that acid-neutralising fillers can sharply reduce the measured HCl yield.&amp;lt;ref name=&amp;quot;TE-139&amp;quot;&amp;gt;Tewarson (2002), p. 3-139.&amp;lt;/ref&amp;gt; Gann and Bryner attribute the low yield from PVC containing much calcium carbonate to the formation of solid calcium chloride.&amp;lt;ref name=&amp;quot;GB-13&amp;quot; /&amp;gt; The rate and amount of generation therefore have to be tied to a formulation and a heating condition.&lt;br /&gt;
&lt;br /&gt;
An electrical cable illustrates the distinction. Its jacket and insulation may contain different materials, and HCl from PVC wiring can serve as a fuel-specific fire signature in a telecommunications facility.&amp;lt;ref name=&amp;quot;CM-76&amp;quot;&amp;gt;Custer and Milke (2008), p. 2-76.&amp;lt;/ref&amp;gt; That is a clue to a possible source, not a measurement of how much HCl remains airborne elsewhere in the building. The gas can be retained in char, deposited on surfaces or carried away with the smoke.&amp;lt;ref name=&amp;quot;TE-143&amp;quot;&amp;gt;Tewarson (2002), p. 3-143.&amp;lt;/ref&amp;gt;&amp;lt;ref name=&amp;quot;GB-25&amp;quot;&amp;gt;Gann and Bryner (2008), p. 6-25.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== Yields and material composition ==&lt;br /&gt;
For pure PVC, Tewarson gives a stoichiometric HCl yield of 0.581 g per gram of material.&amp;lt;ref name=&amp;quot;TE-123&amp;quot;&amp;gt;Tewarson (2002), p. 3-123.&amp;lt;/ref&amp;gt; This is a composition-based upper reference, not the HCl concentration in a room. A specimen with less chlorine than pure PVC has a different maximum. One rigid PVC sheet in Tewarson&amp;#039;s table contained 49.3 % chlorine; converting that chlorine entirely to HCl gives 0.507 g HCl per gram of sheet. Its measured yield in air was 0.479 g/g, about 94.5 % of that specimen-specific maximum.&amp;lt;ref name=&amp;quot;TE-139&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
The same table reports 0.480 g/g for that sheet in an inert atmosphere, 0.263 g/g for one PVC cable in air, and 0.117 g/g for one PVC–plasticiser–calcium carbonate mixture in nitrogen.&amp;lt;ref name=&amp;quot;TE-139&amp;quot; /&amp;gt; These values come from different formulations and conditions. They demonstrate why a single generic yield should not be assigned to every product bearing the PVC name. The table also shows that adding acid neutraliser and changing the proportions of PVC and plasticiser alter the measured release; it does not isolate any one change as the sole cause.&amp;lt;ref name=&amp;quot;TE-139&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
The apparent yield can vary over the course of a test. Early HCl release may precede much of the material&amp;#039;s other mass loss, while later products include carbon monoxide and organic compounds.&amp;lt;ref name=&amp;quot;GB-13&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;TE-138&amp;quot; /&amp;gt; The yields in Tewarson&amp;#039;s table are reported as grams of HCl per gram of tested material. They must be kept separate from a room concentration, which depends on release rate, ventilation, mixing and removal.&amp;lt;ref name=&amp;quot;TE-139&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;GB-24&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;GB-25&amp;quot; /&amp;gt; For this reason, a material balance by itself does not show what an occupant breathes along an escape route.&lt;br /&gt;
&lt;br /&gt;
== Effects on people ==&lt;br /&gt;
HCl is both a sensory and a pulmonary [[Irritant gas]]. It can stimulate the eyes, nose, mouth and throat almost immediately. The handbook describes pain, blinking, tearing and mucus production; shutting the eyes can briefly relieve pain while making wayfinding harder.&amp;lt;ref name=&amp;quot;GB-16&amp;quot; /&amp;gt; A person may also cough or experience bronchoconstriction as HCl reaches the lungs. High exposures can lead to inflammation, pulmonary oedema and death, usually 6–48 hours after exposure in the account given by Gann and Bryner.&amp;lt;ref name=&amp;quot;GB-16&amp;quot; /&amp;gt; The delayed effect is one reason that an ability to keep moving during exposure does not establish that the exposure was harmless.&lt;br /&gt;
&lt;br /&gt;
The handbook describes 75–100 µL/L as extremely irritating to the eyes and upper airway, with possible interference with physical activity needed for escape. For gas volume fractions, 1 µL/L is numerically equal to 1 part per million by volume (ppm).&amp;lt;ref name=&amp;quot;GB-16&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;GB-14&amp;quot;&amp;gt;Gann and Bryner (2008), p. 6-14.&amp;lt;/ref&amp;gt; Purser gives 50–100 ppm as strongly irritating in the human reports he reviews, and describes about 100–500 ppm as potentially slowing escape.&amp;lt;ref name=&amp;quot;PU-115&amp;quot;&amp;gt;Purser (2002), p. 2-115.&amp;lt;/ref&amp;gt;&amp;lt;ref name=&amp;quot;PU-119&amp;quot;&amp;gt;Purser (2002), p. 2-119.&amp;lt;/ref&amp;gt; Those are observations and expert interpretations with different exposure conditions, not a sharp boundary between safe and unsafe air.&lt;br /&gt;
&lt;br /&gt;
The two effects follow different time patterns. Sensory discomfort is principally associated with the concentration encountered at a given moment and does not normally intensify merely because the same concentration continues. Lung injury depends on the inhaled dose, including exposure duration, and may become evident only later.&amp;lt;ref name=&amp;quot;GB-16&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;PU-115&amp;quot; /&amp;gt; Van Rossum likewise describes acidic halogen gases as obstructing vision and breathing during escape, although the Dutch engineering text does not supply an HCl-specific numerical criterion in that discussion.&amp;lt;ref name=&amp;quot;VR-77&amp;quot;&amp;gt;Van Rossum (2027), §7.7.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Animal results do not directly define a human escape limit. In short baboon exposures, trained animals still performed an escape manoeuvre at about 17,000 µL/L for five minutes. Yet deaths followed some exposures that had not stopped the manoeuvre.&amp;lt;ref name=&amp;quot;GB-16&amp;quot; /&amp;gt; The handbook cautions that humans may be endangered at far lower concentrations and that people with impaired lung function may be more susceptible.&amp;lt;ref name=&amp;quot;GB-16&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
For the distinct endpoint of lethality in rats, its Table 6.2.1 gives a 30-minute LC50 of 3,800 µL/L. The N-gas equation on the same page uses 3,700 in an HCl term and attributes small differences between models to experimental uncertainty.&amp;lt;ref name=&amp;quot;GB-18&amp;quot;&amp;gt;Gann and Bryner (2008), p. 6-18.&amp;lt;/ref&amp;gt; Neither number is a validated human escape concentration.&lt;br /&gt;
&lt;br /&gt;
== Concentration criteria and worked example ==&lt;br /&gt;
The 2008 handbook presents an ISO 13571 incapacitating volume fraction of 1,000 µL/L for HCl. It uses a [[Fractional effective concentration]] (FEC) to add the effects of irritants in a modelled smoke atmosphere.&amp;lt;ref name=&amp;quot;GB-16&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;GB-24&amp;quot; /&amp;gt; The HCl contribution at a particular time is the current HCl concentration divided by that criterion. The same source gives 500 µL/L for HF, so a two-gas illustration can be written as follows:&amp;lt;ref name=&amp;quot;GB-16&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;math display=&amp;quot;block&amp;quot;&amp;gt;\mathrm{FEC}_{\mathrm{HCl+HF}}=\frac{C_{\mathrm{HCl}}}{F_{\mathrm{HCl}}}+\frac{C_{\mathrm{HF}}}{F_{\mathrm{HF}}}&amp;lt;/math&amp;gt;&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|+ Symbols for the illustrative FEC calculation&lt;br /&gt;
! Symbol !! Description !! Unit&lt;br /&gt;
|-&lt;br /&gt;
| &amp;lt;math&amp;gt;C_{\mathrm{HCl}}, C_{\mathrm{HF}}&amp;lt;/math&amp;gt; || simultaneous breathing-zone volume fractions of the two gases || µL/L&lt;br /&gt;
|-&lt;br /&gt;
| &amp;lt;math&amp;gt;F_{\mathrm{HCl}}, F_{\mathrm{HF}}&amp;lt;/math&amp;gt; || source-specific incapacitating reference values || µL/L&lt;br /&gt;
|-&lt;br /&gt;
| &amp;lt;math&amp;gt;\mathrm{FEC}&amp;lt;/math&amp;gt; || sum of the concentration fractions at that instant || dimensionless&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
For a hypothetical breathing-zone snapshot of 300 µL/L HCl and 50 µL/L HF, the ISO-based fractions are 300/1,000 = 0.30 and 50/500 = 0.10. Their sum is FEC = 0.40. This is only a worked arithmetic example; it is not a measured fire atmosphere or a prediction of an individual&amp;#039;s escape or later lung injury.&amp;lt;ref name=&amp;quot;GB-16&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;GB-24&amp;quot; /&amp;gt; The full assessment requires the time-varying concentrations of all important gases at the person&amp;#039;s location, while heat and visibility present separate hazards.&amp;lt;ref name=&amp;quot;GB-24&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
The value of 1,000 µL/L should not be confused with every other HCl criterion. Purser&amp;#039;s 2002 SFPE chapter estimates that 200 ppm would impair escape in half the population and 900 ppm would incapacitate half. His first value concerns impaired movement; the second is a more severe endpoint.&amp;lt;ref name=&amp;quot;PU-121&amp;quot;&amp;gt;Purser (2002), p. 2-121.&amp;lt;/ref&amp;gt; The handbook&amp;#039;s 1,000 µL/L is a separate ISO-based incapacitation estimate, rather than a revision of Purser&amp;#039;s 200 ppm value.&amp;lt;ref name=&amp;quot;GB-16&amp;quot; /&amp;gt; The inputs differ in endpoint and judgement, even though both are used to discuss escape in a fire.&lt;br /&gt;
&lt;br /&gt;
For more sensitive people, a criterion of FEC = 1 is insufficient as a guarantee. The 2008 handbook&amp;#039;s illustrative susceptibility distribution associates FEC = 0.3 with 11.4 % of the population still susceptible to incapacitation at lower exposures and says no numerical criterion protects everybody.&amp;lt;ref name=&amp;quot;GB-25&amp;quot; /&amp;gt; Purser also proposes a 0.3 factor for escape impairment, but against his own 200 ppm reference and for a different outcome.&amp;lt;ref name=&amp;quot;PU-121&amp;quot; /&amp;gt; A workplace exposure limit or a one-hour emergency-planning level has yet another purpose; the handbook explicitly warns that occupational long-term limits are normally of little use for short, high fire exposures.&amp;lt;ref name=&amp;quot;GB-14&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;PU-121&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== Movement, deposition and corrosion ==&lt;br /&gt;
The HCl concentration at the point of generation need not persist as smoke moves. Gann and Bryner say that halogen-acid concentrations decay relatively quickly in effluent below 100 °C when water droplets and adsorptive surfaces are present.&amp;lt;ref name=&amp;quot;GB-13&amp;quot; /&amp;gt; They also explain why a mass-loss toxicity model that keeps all gases in fixed proportions can overestimate acid-gas concentration farther from the fire: acid gases stick to surfaces more readily than the narcotic gases.&amp;lt;ref name=&amp;quot;GB-25&amp;quot; /&amp;gt; This is a modelling tendency, not a guaranteed reduction for every compartment or escape route.&lt;br /&gt;
&lt;br /&gt;
The deposited chloride creates another exposure pathway for property. In a PVC floor-covering fire test in an unventilated room measuring 2.8 m × 2.8 m × 2.4 m, about half of the original chloride ions were deposited on walls.&amp;lt;ref name=&amp;quot;TE-138&amp;quot; /&amp;gt; In a separate apparatus experiment, HCl deposition on wet filter paper was almost four times that on dry paper.&amp;lt;ref name=&amp;quot;TE-138&amp;quot; /&amp;gt; Neither fraction should be applied unaltered to a different room: humidity, surface material, air movement and the fire itself affect deposition.&amp;lt;ref name=&amp;quot;TE-137&amp;quot;&amp;gt;Tewarson (2002), p. 3-137.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
HCl and deposited chloride can corrode metal and damage electronics. Tewarson describes chloride deposits reacting with zinc to form hygroscopic zinc chloride, which can form a conductive solution and lead to electrical shorting at low relative humidity.&amp;lt;ref name=&amp;quot;TE-137&amp;quot; /&amp;gt; In one handbook discussion, electronic equipment is described as vulnerable to smoke containing 0.01 % HCl, especially where restoration does not start promptly.&amp;lt;ref name=&amp;quot;MK-46&amp;quot;&amp;gt;Milke and Klote (2008), p. 18-46.&amp;lt;/ref&amp;gt; That statement addresses potential equipment damage, not an occupant tenability criterion. A different NFPA chapter says that acid gases are especially harmful to electronics, yet HCl deposited on intervening walls may reduce the concentration reaching equipment farther from the fire.&amp;lt;ref name=&amp;quot;HB-133&amp;quot;&amp;gt;Hurley and Bukowski (2008), p. 3-133.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
These competing effects make telecommunications facilities a clear example of the dual hazard. PVC wiring can identify the likely source of HCl, while smoke movement and deposition determine both exposure and contamination.&amp;lt;ref name=&amp;quot;CM-76&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;HB-133&amp;quot; /&amp;gt; In a fire involving a sensitive installation, an airborne reading alone cannot describe the chloride left on equipment. Equally, a contaminated surface does not by itself reconstruct the concentration that an occupant breathed earlier.&amp;lt;ref name=&amp;quot;TE-138&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;GB-25&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== Using the data in a fire assessment ==&lt;br /&gt;
An assessment starts with the actual products present, their plausible decomposition conditions and the location of people or assets. A yield from a laboratory specimen is an input to a release estimate; it is not automatically an input concentration for a person&amp;#039;s breathing zone.&amp;lt;ref name=&amp;quot;GB-24&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;TE-139&amp;quot; /&amp;gt; A fire-growth and smoke-spread calculation may distribute those gases through a building, but the handbook notes that the gas yields themselves remain inputs rather than being predicted by the fire model&amp;#039;s combustion chemistry.&amp;lt;ref name=&amp;quot;GB-24&amp;quot; /&amp;gt; The analysis must keep temperature, ventilation and deposition assumptions visible.&lt;br /&gt;
&lt;br /&gt;
The FEC calculation addresses immediate escape impairment from sensory irritants. It does not cover the dose-dependent lung effects of prolonged HCl exposure, nor the cumulative action of asphyxiants, heat or obscuration.&amp;lt;ref name=&amp;quot;GB-16&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;GB-24&amp;quot; /&amp;gt; The 30-minute rat LC50 and Purser&amp;#039;s derived 114,000 ppm·min dose belong to lethality discussions with specified endpoints and populations.&amp;lt;ref name=&amp;quot;GB-18&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;PU-119&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;PU-122&amp;quot;&amp;gt;Purser (2002), p. 2-122.&amp;lt;/ref&amp;gt; Dividing that dose by an arbitrary concentration would assume a linear concentration–time response outside the tested condition; it cannot establish a safe exposure duration or a human incapacitation time.&lt;br /&gt;
&lt;br /&gt;
Lastly, source disagreement should remain visible. The handbook&amp;#039;s 225–275 °C description of ready release and Tewarson&amp;#039;s report of an onset as low as 100 °C refer to different circumstances.&amp;lt;ref name=&amp;quot;GB-13&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;TE-138&amp;quot; /&amp;gt; The 200, 900 and 1,000 ppm values describe different escape endpoints or models.&amp;lt;ref name=&amp;quot;PU-121&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;GB-16&amp;quot; /&amp;gt; Concentrations in a compartment may also change through deposition while the contaminant remains on surfaces.&amp;lt;ref name=&amp;quot;GB-25&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;TE-138&amp;quot; /&amp;gt; These are reasons to select material-specific data and an explicit endpoint, rather than to treat any single HCl number as a universal fire limit.&lt;br /&gt;
&lt;br /&gt;
== See also ==&lt;br /&gt;
* [[Telecommunications facility]]&lt;br /&gt;
* [[Smoke inhalation]]&lt;br /&gt;
* [[Tenability criteria]]&lt;br /&gt;
* [[LC50]]&lt;br /&gt;
&lt;br /&gt;
== Notes ==&lt;br /&gt;
&amp;lt;references /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== References ==&lt;br /&gt;
* Benedetti, R. P., &amp;amp; Colonna, G. R. (2008). Polymeric materials. In A. E. Cote, C. C. Grant, J. R. Hall Jr., &amp;amp; R. E. Solomon (Eds.), &amp;#039;&amp;#039;Fire protection handbook&amp;#039;&amp;#039; (20th ed., pp. 6-209–6-231). National Fire Protection Association.&lt;br /&gt;
* Custer, R. L. P., &amp;amp; Milke, J. A. (2008). Fundamentals of fire detection. In A. E. Cote, C. C. Grant, J. R. Hall Jr., &amp;amp; R. E. Solomon (Eds.), &amp;#039;&amp;#039;Fire protection handbook&amp;#039;&amp;#039; (20th ed., pp. 2-75–2-78). National Fire Protection Association.&lt;br /&gt;
* Gann, R. G., &amp;amp; Bryner, N. P. (2008). Combustion products and their effects on life safety. In A. E. Cote, C. C. Grant, J. R. Hall Jr., &amp;amp; R. E. Solomon (Eds.), &amp;#039;&amp;#039;Fire protection handbook&amp;#039;&amp;#039; (20th ed., pp. 6-11–6-34). National Fire Protection Association.&lt;br /&gt;
* Hurley, M. J., &amp;amp; Bukowski, R. W. (2008). Fire hazard analysis techniques. In A. E. Cote, C. C. Grant, J. R. Hall Jr., &amp;amp; R. E. Solomon (Eds.), &amp;#039;&amp;#039;Fire protection handbook&amp;#039;&amp;#039; (20th ed., pp. 3-121–3-134). National Fire Protection Association.&lt;br /&gt;
* Milke, J. A., &amp;amp; Klote, J. H. (2008). Smoke movement in buildings. In A. E. Cote, C. C. Grant, J. R. Hall Jr., &amp;amp; R. E. Solomon (Eds.), &amp;#039;&amp;#039;Fire protection handbook&amp;#039;&amp;#039; (20th ed., pp. 18-43–18-55). National Fire Protection Association.&lt;br /&gt;
* Purser, D. A. (2002). Toxicity assessment of combustion products. In P. J. DiNenno, D. Drysdale, C. L. Beyler, W. D. Walton, R. L. P. Custer, J. R. Hall Jr., &amp;amp; J. M. Watts Jr. (Eds.), &amp;#039;&amp;#039;SFPE handbook of fire protection engineering&amp;#039;&amp;#039; (3rd ed., pp. 2-83–2-171). National Fire Protection Association; Society of Fire Protection Engineers.&lt;br /&gt;
* Tewarson, A. (2002). Generation of heat and chemical compounds in fires. In P. J. DiNenno, D. Drysdale, C. L. Beyler, W. D. Walton, R. L. P. Custer, J. R. Hall Jr., &amp;amp; J. M. Watts Jr. (Eds.), &amp;#039;&amp;#039;SFPE handbook of fire protection engineering&amp;#039;&amp;#039; (3rd ed., pp. 3-82–3-161). National Fire Protection Association; Society of Fire Protection Engineers.&lt;br /&gt;
* Van Rossum, E. (2027). &amp;#039;&amp;#039;Introduction to Fire Safety Engineering&amp;#039;&amp;#039;. Fire Safety Academy.&lt;br /&gt;
&lt;br /&gt;
[[Category:Smoke, Toxicity &amp;amp; Tenability]]&lt;/div&gt;</summary>
		<author><name>Peter</name></author>
	</entry>
</feed>