	<entry>
		<id>https://fire-safety.academy/w/index.php?title=Heat_detector&amp;diff=2823&amp;oldid=prev</id>
		<title>Emma: Revise Basic article against FSE writing guidelines: sourced explanations, examples and references (GPT-6)</title>
		<link rel="alternate" type="text/html" href="https://fire-safety.academy/w/index.php?title=Heat_detector&amp;diff=2823&amp;oldid=prev"/>
		<updated>2026-11-02T18:42:39Z</updated>

		<summary type="html">&lt;p&gt;Revise Basic article against FSE writing guidelines: sourced explanations, examples and references (GPT-6)&lt;/p&gt;
&lt;a href=&quot;https://fire-safety.academy/w/index.php?title=Heat_detector&amp;amp;diff=2823&amp;amp;oldid=974&quot;&gt;Show changes&lt;/a&gt;</summary>
		<author><name>Emma</name></author>
	</entry>
	<entry>
		<id>https://fire-safety.academy/w/index.php?title=Heat_detector&amp;diff=974&amp;oldid=prev</id>
		<title>Sanne: Add diagrams fse-heat-detector-v1.svg, fse-heat-detector-v2.svg, fse-heat-detector-v3.svg (level-1 visual plan)</title>
		<link rel="alternate" type="text/html" href="https://fire-safety.academy/w/index.php?title=Heat_detector&amp;diff=974&amp;oldid=prev"/>
		<updated>2026-11-02T07:09:21Z</updated>

		<summary type="html">&lt;p&gt;Add diagrams fse-heat-detector-v1.svg, fse-heat-detector-v2.svg, fse-heat-detector-v3.svg (level-1 visual plan)&lt;/p&gt;
&lt;table style=&quot;background-color: #fff; color: #202122;&quot; data-mw=&quot;interface&quot;&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;tr class=&quot;diff-title&quot; lang=&quot;en&quot;&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;← Older revision&lt;/td&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;Revision as of 08:09, 2 November 2026&lt;/td&gt;
				&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l22&quot;&gt;Line 22:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 22:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Heat reaches the sensing element by convection, with conduction into the element and possible radiation affecting its boundary. The element then warms according to its mass and thermal properties. This creates thermal lag, where the surrounding air can be hotter than the element&amp;#039;s rated temperature at activation.&amp;lt;ref name=&amp;quot;NUREG-1805-12-2&amp;quot;&amp;gt;U.S. Nuclear Regulatory Commission (2005), p. 12-2.&amp;lt;/ref&amp;gt;&amp;lt;ref name=&amp;quot;Schifiliti-4-7&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Heat reaches the sensing element by convection, with conduction into the element and possible radiation affecting its boundary. The element then warms according to its mass and thermal properties. This creates thermal lag, where the surrounding air can be hotter than the element&amp;#039;s rated temperature at activation.&amp;lt;ref name=&amp;quot;NUREG-1805-12-2&amp;quot;&amp;gt;U.S. Nuclear Regulatory Commission (2005), p. 12-2.&amp;lt;/ref&amp;gt;&amp;lt;ref name=&amp;quot;Schifiliti-4-7&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-deleted&quot;&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;[[File:fse-heat-detector-v1.svg|thumb|upright=1.5|alt=Plume and ceiling jet transfer heat to a detector element, which responds after a lag.|Heat-detector response depends on ceiling-jet exposure and thermal lag. Based on Australian Building Codes Board et al. (2005), p. 2.7-2 and Schifiliti, Meacham, and Custer (2002), p. 4-7.]]&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Detector response is not determined by ambient room temperature alone. Fire heat release rate, plume geometry and airflow change the local exposure. A detector that is appropriately rated for one ceiling and fire can respond differently in another.&amp;lt;ref name=&amp;quot;Schifiliti-4-7&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;Schifiliti-4-9&amp;quot;&amp;gt;Schifiliti, Meacham, and Custer (2002), p. 4-9.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Detector response is not determined by ambient room temperature alone. Fire heat release rate, plume geometry and airflow change the local exposure. A detector that is appropriately rated for one ceiling and fire can respond differently in another.&amp;lt;ref name=&amp;quot;Schifiliti-4-7&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;Schifiliti-4-9&amp;quot;&amp;gt;Schifiliti, Meacham, and Custer (2002), p. 4-9.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l32&quot;&gt;Line 32:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 33:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Thermal inertia causes the element to lag behind the surrounding gas temperature. The rated temperature is reached only after enough energy has been absorbed, so the air temperature at activation can be higher than the element&amp;#039;s nominal rating. This is one reason detector response cannot be predicted from rating alone.&amp;lt;ref name=&amp;quot;NUREG-1805-12-2&amp;quot;&amp;gt;U.S. Nuclear Regulatory Commission (2005), p. 12-2.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Thermal inertia causes the element to lag behind the surrounding gas temperature. The rated temperature is reached only after enough energy has been absorbed, so the air temperature at activation can be higher than the element&amp;#039;s nominal rating. This is one reason detector response cannot be predicted from rating alone.&amp;lt;ref name=&amp;quot;NUREG-1805-12-2&amp;quot;&amp;gt;U.S. Nuclear Regulatory Commission (2005), p. 12-2.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-deleted&quot;&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;[[File:fse-heat-detector-v2.svg|thumb|upright=1.5|alt=Gas temperature rises quickly while element temperature follows more slowly past the rating.|Element temperature lags behind gas temperature. Based on U.S. Nuclear Regulatory Commission (2005), p. 12-2 and Schifiliti, Meacham, and Custer (2002), p. 4-7.]]&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The lumped thermal model links element temperature with gas temperature and a convective coefficient. That model assumes a suitable thermal mass and exposure description. Detector-specific RTI data and the fire&amp;#039;s time-dependent heat flux must be consistent with it.&amp;lt;ref name=&amp;quot;IFEG-2.7-2&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;Schifiliti-4-7&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The lumped thermal model links element temperature with gas temperature and a convective coefficient. That model assumes a suitable thermal mass and exposure description. Detector-specific RTI data and the fire&amp;#039;s time-dependent heat flux must be consistent with it.&amp;lt;ref name=&amp;quot;IFEG-2.7-2&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;Schifiliti-4-7&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l44&quot;&gt;Line 44:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 46:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Fixed-temperature and rate-of-rise devices can favour different numbers of detectors. In one analysis, more fixed-temperature devices were required for a given objective than rate-of-rise devices, but this conclusion was not universal. Device type and scenario determine the comparison.&amp;lt;ref name=&amp;quot;Schifiliti-4-19&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Fixed-temperature and rate-of-rise devices can favour different numbers of detectors. In one analysis, more fixed-temperature devices were required for a given objective than rate-of-rise devices, but this conclusion was not universal. Device type and scenario determine the comparison.&amp;lt;ref name=&amp;quot;Schifiliti-4-19&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-deleted&quot;&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;[[File:fse-heat-detector-v3.svg|thumb|upright=1.5|alt=Fixed-temperature alarm at a threshold and rate-of-rise alarm during rapid increase.|Fixed-temperature and rate-of-rise detection principles. Based on U.S. Nuclear Regulatory Commission (2005), pp. 12-3–12-4 and Schifiliti, Meacham, and Custer (2002), p. 4-19.]]&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;C/VM2 uses a critical-velocity method and a heat-release rate method for heat-detector response in its 2025 design scenarios. Those are specific analytical methods, not universal guarantees of activation time. The required fire and ceiling conditions must be represented in the calculation.&amp;lt;ref name=&amp;quot;CVM2-26&amp;quot;&amp;gt;Ministry of Business, Innovation and Employment (2025), p. 26.&amp;lt;/ref&amp;gt;&amp;lt;ref name=&amp;quot;IFEG-2.7-2&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;C/VM2 uses a critical-velocity method and a heat-release rate method for heat-detector response in its 2025 design scenarios. Those are specific analytical methods, not universal guarantees of activation time. The required fire and ceiling conditions must be represented in the calculation.&amp;lt;ref name=&amp;quot;CVM2-26&amp;quot;&amp;gt;Ministry of Business, Innovation and Employment (2025), p. 26.&amp;lt;/ref&amp;gt;&amp;lt;ref name=&amp;quot;IFEG-2.7-2&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;

&lt;!-- diff cache key firesb_pjbsiy42-wiki_:diff:1.41:old-693:rev-974:php=table --&gt;
&lt;/table&gt;</summary>
		<author><name>Sanne</name></author>
	</entry>
	<entry>
		<id>https://fire-safety.academy/w/index.php?title=Heat_detector&amp;diff=693&amp;oldid=prev</id>
		<title>Jan: New FSE wiki article: Heat detector (written by Kimi Code CLI)</title>
		<link rel="alternate" type="text/html" href="https://fire-safety.academy/w/index.php?title=Heat_detector&amp;diff=693&amp;oldid=prev"/>
		<updated>2026-11-02T01:16:08Z</updated>

		<summary type="html">&lt;p&gt;New FSE wiki article: Heat detector (written by Kimi Code CLI)&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;A &amp;#039;&amp;#039;&amp;#039;Heat detector&amp;#039;&amp;#039;&amp;#039; is a fire-detection device that responds to thermal energy transferred from a fire to its sensing element. Fixed-temperature devices operate at a selected temperature, while rate-of-rise and rate-compensated devices respond to temperature change. Most heat detectors are located on or near the ceiling, where a ceiling jet delivers hot gases.&amp;lt;ref name=&amp;quot;NUREG-1805-12-1&amp;quot;&amp;gt;U.S. Nuclear Regulatory Commission (2005), pp. 12-1–12-2.&amp;lt;/ref&amp;gt;&amp;lt;ref name=&amp;quot;IFEG-2.7-2&amp;quot;&amp;gt;Australian Building Codes Board et al. (2005), p. 2.7-2.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Heat detectors are among the oldest automatic fire detectors and typically have a low false-alarm rate. They usually respond later than smoke detectors because they do not detect smoke. They are most suitable for confined spaces with rapidly growing high-heat fires, environments unsuitable for other detectors or applications where activation speed is secondary.&amp;lt;ref name=&amp;quot;NUREG-1805-12-1&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
The device measures a prescribed change in a physical or electrical property of its material or gas. That response depends on heat transfer, sensing-element properties and thermal inertia, so the air temperature at activation can differ from the element&amp;#039;s rated temperature.&amp;lt;ref name=&amp;quot;NUREG-1805-12-2&amp;quot;&amp;gt;U.S. Nuclear Regulatory Commission (2005), p. 12-2.&amp;lt;/ref&amp;gt;&amp;lt;ref name=&amp;quot;Schifiliti-4-7&amp;quot;&amp;gt;Schifiliti, Meacham, and Custer (2002), p. 4-7.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== Detector types ==&lt;br /&gt;
&lt;br /&gt;
Fixed-temperature heat detectors operate when their sensing element reaches a specified point. Fusible elements melt at a predetermined temperature and close alarm contacts, while bimetallic and electronic elements use other property changes. Fused elements and line sections can require replacement rather than reset.&amp;lt;ref name=&amp;quot;NUREG-1805-12-3&amp;quot;&amp;gt;U.S. Nuclear Regulatory Commission (2005), p. 12-3.&amp;lt;/ref&amp;gt;&amp;lt;ref name=&amp;quot;NUREG-1805-12-4&amp;quot;&amp;gt;U.S. Nuclear Regulatory Commission (2005), p. 12-4.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Rate-of-rise heat detectors respond to the rate at which temperature increases. Rate-compensated designs account for that increase in a different way, using compensation to reduce inappropriate response. These approaches can support earlier detection in suitable scenarios, but they still depend on heat transfer and the selected set point.&amp;lt;ref name=&amp;quot;NUREG-1805-12-4&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;Schifiliti-4-7&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Line-type detectors use a continuous sensitive element along a cable or tube. One arrangement melts insulation so that two conductors contact, while another uses a temperature-sensitive semiconductor to increase current. These provide spatial coverage different from a compact spot detector.&amp;lt;ref name=&amp;quot;NUREG-1805-12-4&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Pneumatic detectors use expansion of heated air in a tube or chamber to move a diaphragm and actuate the alarm. They can be available as line or spot types. Their operating principle differs from fusible-metal devices but still relies on heat reaching and changing the sensing system.&amp;lt;ref name=&amp;quot;NUREG-1805-12-4&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
[[Flame detector]] technologies detect radiant energy or flame characteristics rather than only convected heat. They address a different indication of fire and should not be used as interchangeable with heat detectors. The scenario determines which indication provides timely and reliable detection.&amp;lt;ref name=&amp;quot;Schifiliti-4-30&amp;quot;&amp;gt;Schifiliti, Meacham, and Custer (2002), pp. 4-30–4-31.&amp;lt;/ref&amp;gt;&amp;lt;ref name=&amp;quot;IFEG-1.8-7&amp;quot;&amp;gt;Australian Building Codes Board et al. (2005), p. 1.8-7.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== Heat transfer and ceiling jet ==&lt;br /&gt;
&lt;br /&gt;
A [[Ceiling jet]] forms when the plume reaches the ceiling and spreads horizontally. Hot gases transfer energy to the ceiling and to heat-responsive devices. The detector&amp;#039;s response therefore depends on the plume and ceiling-jet temperatures, velocity and position relative to the device.&amp;lt;ref name=&amp;quot;IFEG-2.7-2&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;NUREG-1805-12-2&amp;quot;&amp;gt;U.S. Nuclear Regulatory Commission (2005), p. 12-2.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Heat reaches the sensing element by convection, with conduction into the element and possible radiation affecting its boundary. The element then warms according to its mass and thermal properties. This creates thermal lag, where the surrounding air can be hotter than the element&amp;#039;s rated temperature at activation.&amp;lt;ref name=&amp;quot;NUREG-1805-12-2&amp;quot;&amp;gt;U.S. Nuclear Regulatory Commission (2005), p. 12-2.&amp;lt;/ref&amp;gt;&amp;lt;ref name=&amp;quot;Schifiliti-4-7&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Detector response is not determined by ambient room temperature alone. Fire heat release rate, plume geometry and airflow change the local exposure. A detector that is appropriately rated for one ceiling and fire can respond differently in another.&amp;lt;ref name=&amp;quot;Schifiliti-4-7&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;Schifiliti-4-9&amp;quot;&amp;gt;Schifiliti, Meacham, and Custer (2002), p. 4-9.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Smooth ceilings support more predictable distribution of hot gases, while obstructions and unusual ceiling forms change the flow. Spacing and location should therefore be based on actual construction and expected fire position rather than on a generic ceiling grid.&amp;lt;ref name=&amp;quot;NUREG-1805-12-3&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;Schifiliti-4-5&amp;quot;&amp;gt;Schifiliti, Meacham, and Custer (2002), p. 4-5.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== Response time index and thermal lag ==&lt;br /&gt;
&lt;br /&gt;
[[Response time index (RTI)]] characterises the thermal responsiveness of a heat-sensing element. It relates the element&amp;#039;s temperature change to its exposure and is used to estimate activation time under changing conditions. A lower-RTI device generally responds more quickly to a developing exposure, although the complete model still matters.&amp;lt;ref name=&amp;quot;Schifiliti-4-7&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;IFEG-2.7-2&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Thermal inertia causes the element to lag behind the surrounding gas temperature. The rated temperature is reached only after enough energy has been absorbed, so the air temperature at activation can be higher than the element&amp;#039;s nominal rating. This is one reason detector response cannot be predicted from rating alone.&amp;lt;ref name=&amp;quot;NUREG-1805-12-2&amp;quot;&amp;gt;U.S. Nuclear Regulatory Commission (2005), p. 12-2.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
The lumped thermal model links element temperature with gas temperature and a convective coefficient. That model assumes a suitable thermal mass and exposure description. Detector-specific RTI data and the fire&amp;#039;s time-dependent heat flux must be consistent with it.&amp;lt;ref name=&amp;quot;IFEG-2.7-2&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;Schifiliti-4-7&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
A heat detector can be approximated as having a low RTI for smoke-detector response in some nuclear methods. This provides a way to use heat-response analysis for smoke detectors, but it is an approximation rather than a complete smoke-response model. Smoke properties and entry processes add further uncertainty.&amp;lt;ref name=&amp;quot;NUREG-1805-11-6&amp;quot;&amp;gt;U.S. Nuclear Regulatory Commission (2005), p. 11-6.&amp;lt;/ref&amp;gt;&amp;lt;ref name=&amp;quot;Schifiliti-4-23&amp;quot;&amp;gt;Schifiliti, Meacham, and Custer (2002), p. 4-23.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== Activation time ==&lt;br /&gt;
&lt;br /&gt;
[[Detector activation time]] includes heat production, transport to the detector and heating of the sensing element. Fire growth, location, spacing and thermal properties all influence it. A faster fire can produce a shorter activation time under otherwise similar conditions, but the relationship need not be simple.&amp;lt;ref name=&amp;quot;Schifiliti-4-7&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;Schifiliti-4-9&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Spacing determines how far hot gases must travel before reaching the device. Schifiliti and colleagues analyse how ceiling height and detector spacing affect response, with different outcomes for fixed-temperature and rate-of-rise devices. These models are scenario-specific and should not be converted into a universal maximum spacing.&amp;lt;ref name=&amp;quot;Schifiliti-4-5&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;Schifiliti-4-19&amp;quot;&amp;gt;Schifiliti, Meacham, and Custer (2002), p. 4-19.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Fixed-temperature and rate-of-rise devices can favour different numbers of detectors. In one analysis, more fixed-temperature devices were required for a given objective than rate-of-rise devices, but this conclusion was not universal. Device type and scenario determine the comparison.&amp;lt;ref name=&amp;quot;Schifiliti-4-19&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
C/VM2 uses a critical-velocity method and a heat-release rate method for heat-detector response in its 2025 design scenarios. Those are specific analytical methods, not universal guarantees of activation time. The required fire and ceiling conditions must be represented in the calculation.&amp;lt;ref name=&amp;quot;CVM2-26&amp;quot;&amp;gt;Ministry of Business, Innovation and Employment (2025), p. 26.&amp;lt;/ref&amp;gt;&amp;lt;ref name=&amp;quot;IFEG-2.7-2&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== Heat and smoke detection ==&lt;br /&gt;
&lt;br /&gt;
A [[Smoke detector]] usually activates before a heat detector because smoke is produced earlier and does not require the same heat output. Using both can provide complementary information about the fire&amp;#039;s development. The combination should be selected for its actual response rather than assuming redundancy guarantees earlier detection.&amp;lt;ref name=&amp;quot;NUREG-1805-12-1&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;Schifiliti-4-23&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Heat detectors typically have a low false-alarm rate, while smoke detectors can be more susceptible to nuisance signatures. That does not make heat detection universally better, because slower activation can reduce available escape time. Selection must balance timeliness and reliability.&amp;lt;ref name=&amp;quot;NUREG-1805-12-1&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;Proulx-3-351&amp;quot;&amp;gt;Proulx (2002), p. 3-351.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Smoke-detector response can be approximated using heat-response models in some methods, but actual smoke entry and particle properties remain important. A low-RTI heat model alone does not describe every smoke-detector response. The two measurement problems should be distinguished.&amp;lt;ref name=&amp;quot;NUREG-1805-11-6&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;Schifiliti-4-23&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Heat and smoke detection can also initiate different responses. Heat detectors may be used to activate sprinklers or other thermal devices, while smoke detection can support earlier alarm and investigation. The complete alarm and suppression sequence should be assessed rather than only the sensor&amp;#039;s threshold.&amp;lt;ref name=&amp;quot;IFEG-2.7-2&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;NUREG-1805-11-6&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== Ambient conditions and unwanted alarms ==&lt;br /&gt;
&lt;br /&gt;
Detector rating must suit the ambient ceiling temperature. NUREG-1805 lists ordinary detectors rated from 57 to 74 °C for ceilings not exceeding 37.7 °C, with higher ratings for hotter environments. Choosing an inappropriate rating can cause premature activation and reduce credibility.&amp;lt;ref name=&amp;quot;NUREG-1805-12-3&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Hot rooms such as boiler rooms and dry kilns require special consideration. Detectors intended for those conditions need to withstand high ambient temperatures for long periods and should be selected to avoid nuisance activation. Normal temperature conditions should be at least 6.6 °C below the rating for low-degree devices in the cited guidance.&amp;lt;ref name=&amp;quot;NUREG-1805-12-3&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
[[Unwanted fire alarms]] can still occur even though heat detectors have a low false-alarm rate. Abnormal heat from uninsulated pipes, unsuitable placement or an incorrect rating can produce a non-fire signal. Those conditions should be investigated and corrected rather than accepted as unavoidable.&amp;lt;ref name=&amp;quot;NUREG-1805-12-3&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;Proulx-3-351&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Unwanted activation is not the only concern. Excessive sensitivity to an unusual environment can delay detection if the rating is raised unnecessarily to avoid it. The detector must be chosen for both the environment and the required response time.&amp;lt;ref name=&amp;quot;NUREG-1805-12-3&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;Schifiliti-4-7&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== Fire alarm system integration ==&lt;br /&gt;
&lt;br /&gt;
A [[Fire alarm system]] uses the detector&amp;#039;s signal to initiate alarm and notification. Detector selection should therefore include control, communication and the intended response. An appropriate heat detector can still fail to protect if the rest of the chain does not work.&amp;lt;ref name=&amp;quot;Schifiliti-4-1&amp;quot;&amp;gt;Schifiliti, Meacham, and Custer (2002), pp. 4-1–4-2.&amp;lt;/ref&amp;gt;&amp;lt;ref name=&amp;quot;IFEG-1.8-7&amp;quot;&amp;gt;Australian Building Codes Board et al. (2005), p. 1.8-7.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Heat detectors can be used in combination with smoke detectors and with suppression systems. Each initiation path should be defined, including whether an alarm, suppression action or smoke-control response follows. Backup paths should be checked for common failures rather than assumed independent.&amp;lt;ref name=&amp;quot;IFEG-1.2-24&amp;quot;&amp;gt;Australian Building Codes Board et al. (2005), p. 1.2-24.&amp;lt;/ref&amp;gt;&amp;lt;ref name=&amp;quot;IFEG-2.7-2&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
The detector&amp;#039;s response must be converted into an intelligible alarm. Occupants need to know what the signal means and what to do, and that message must be audible and credible. A low false-alarm rate alone does not create an effective evacuation.&amp;lt;ref name=&amp;quot;Proulx-3-350&amp;quot;&amp;gt;Proulx (2002), pp. 3-350–3-351.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Testing should cover the complete activation and notification chain. Fusible elements and line sections may need replacement, and control and sounders must be checked. System maintenance should preserve the intended rating, placement and operation.&amp;lt;ref name=&amp;quot;NUREG-1805-12-3&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;CVM2-13&amp;quot;&amp;gt;Ministry of Business, Innovation and Employment (2025), p. 13.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== Reliability and limitations ==&lt;br /&gt;
&lt;br /&gt;
Heat detectors are usually slower than smoke detectors and may not provide enough early warning in life-threatening scenarios. Their suitability depends on expected fire growth and the available response time. Using them where early detection is essential requires careful justification.&amp;lt;ref name=&amp;quot;NUREG-1805-12-1&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Their low false-alarm rate does not mean no unwanted alarms. Incorrect rating, abnormal ambient heat and unsuitable placement can still produce false or premature signals. Those conditions should be controlled through correct selection and management.&amp;lt;ref name=&amp;quot;NUREG-1805-12-3&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;Proulx-3-351&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Rated temperature and activation temperature are not identical. Thermal lag can make the surrounding air hotter than the element&amp;#039;s rating when it finally responds, and ceiling-jet temperature is not room-average temperature. Reporting should identify which temperature is meant.&amp;lt;ref name=&amp;quot;NUREG-1805-12-2&amp;quot;&amp;gt;U.S. Nuclear Regulatory Commission (2005), p. 12-2.&amp;lt;/ref&amp;gt;&amp;lt;ref name=&amp;quot;Schifiliti-4-7&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Finally, a heat detector is only one part of the alarm system. It must produce a signal that is transmitted, understood and acted upon. Effective fire safety depends on that complete sequence rather than on the detector&amp;#039;s nominal rating alone.&amp;lt;ref name=&amp;quot;Schifiliti-4-1&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;Proulx-3-350&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Response modelling should distinguish the surrounding gas, the ceiling jet and the sensing element. Their temperatures can differ, and the element responds only after absorbing enough energy. Reporting one ambient room temperature cannot represent that sequence or the thermal lag at activation.&amp;lt;ref name=&amp;quot;NUREG-1805-12-2&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;Schifiliti-4-7&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
RTI data should be tied to the actual element and exposure. A low-RTI element can respond quickly to a suitable ceiling jet, but changing its mass, mounting or boundary conditions can change the result. Detector-specific evidence is therefore necessary when activation time is critical.&amp;lt;ref name=&amp;quot;Schifiliti-4-7&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;IFEG-2.7-2&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
For spacing, the fire&amp;#039;s position and the ceiling&amp;#039;s shape should be established before applying a grid. A detector placed far from the plume can receive a weaker or later exposure, and obstructions can redirect that flow. A maximum spacing from one scenario should not be used as a universal allowance.&amp;lt;ref name=&amp;quot;Schifiliti-4-5&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;Schifiliti-4-19&amp;quot;&amp;gt;Schifiliti, Meacham, and Custer (2002), p. 4-19.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
For unwanted alarms, abnormal heat and rating should be reviewed before sensitivity is changed. An incorrect rating can create premature activation, while an unnecessarily high rating can delay genuine detection. Correct selection requires both the ambient condition and the required fire response.&amp;lt;ref name=&amp;quot;NUREG-1805-12-3&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;Proulx-3-351&amp;quot;&amp;gt;Proulx (2002), p. 3-351.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
A final evaluation should link detector response with notification and acceptance criteria. If the alarm arrives after the required intervention time, a lower false-alarm rate does not make the system successful. The detector must provide timely and credible information for the intended response.&amp;lt;ref name=&amp;quot;Schifiliti-4-1&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;Proulx-3-350&amp;quot;&amp;gt;Proulx (2002), pp. 3-350–3-351.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
The detector&amp;#039;s evidence should distinguish rated temperature, ceiling-jet temperature and element temperature. They describe different stages of exposure and can differ at activation. Keeping them separate prevents a nominal rating from being mistaken for a direct measurement of the room&amp;#039;s condition.&amp;lt;ref name=&amp;quot;NUREG-1805-12-2&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;Schifiliti-4-7&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
For acceptance, activation time should be compared with the required response, not just with another detector. A slower heat detector can be suitable for some scenarios, while an earlier but less reliable alternative can be preferable in others. The decision must consider both timeliness and the credibility of the resulting alarm.&amp;lt;ref name=&amp;quot;NUREG-1805-12-1&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;Proulx-3-351&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
A complete report should identify the detector type, rating, RTI where relevant, placement and the scenario used for evaluation. It should also record whether abnormal ambient conditions were included. Those details allow another reviewer to assess whether the detector&amp;#039;s performance applies to the intended installation.&amp;lt;ref name=&amp;quot;NUREG-1805-12-3&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;Schifiliti-4-7&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
For final acceptance, the complete exposure and response should be documented. The fire&amp;#039;s location, ceiling-jet behaviour, element properties and thermal lag determine activation, while the rating alone does not predict it. Those inputs should be shown explicitly so that another reviewer can assess the result.&amp;lt;ref name=&amp;quot;Schifiliti-4-7&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;IFEG-2.7-2&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
The detector should then be judged by the response it enables. An appropriate activation is one that produces a credible alarm and enough time for the intended action, not simply one that proves the element changed state. This connects heat detection with evacuation and fire-safety performance.&amp;lt;ref name=&amp;quot;Schifiliti-4-1&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;Proulx-3-350&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== See also ==&lt;br /&gt;
&lt;br /&gt;
* [[Detector activation time]]&lt;br /&gt;
* [[Response time index (RTI)]]&lt;br /&gt;
* [[Smoke detector]]&lt;br /&gt;
&lt;br /&gt;
== Notes ==&lt;br /&gt;
&lt;br /&gt;
&amp;lt;references /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== References ==&lt;br /&gt;
&lt;br /&gt;
* Australian Building Codes Board, National Research Council of Canada, International Code Council, &amp;amp; Department of Building and Housing New Zealand. (2005). &amp;#039;&amp;#039;International fire engineering guidelines&amp;#039;&amp;#039; (2005 ed.). Australian Building Codes Board.&lt;br /&gt;
* Ministry of Business, Innovation and Employment. (2025). &amp;#039;&amp;#039;C protection from fire: Verification method C/VM2&amp;#039;&amp;#039; (2nd ed.). New Zealand Government.&lt;br /&gt;
* Proulx, G. (2002). Movement of people: The evacuation timing. In P. J. DiNenno (Ed.), &amp;#039;&amp;#039;SFPE handbook of fire protection engineering&amp;#039;&amp;#039; (3rd ed.). National Fire Protection Association.&lt;br /&gt;
* Schifiliti, R. P., Meacham, B. J., &amp;amp; Custer, R. L. P. (2002). Design of detection systems. In P. J. DiNenno (Ed.), &amp;#039;&amp;#039;SFPE handbook of fire protection engineering&amp;#039;&amp;#039; (3rd ed.). National Fire Protection Association.&lt;br /&gt;
* U.S. Nuclear Regulatory Commission. (2005). &amp;#039;&amp;#039;Fire dynamics tools: Quantitative fire hazard analysis methods for the U.S. nuclear regulatory commission fire protection inspection program&amp;#039;&amp;#039; (NUREG-1805). Author.&lt;br /&gt;
&lt;br /&gt;
[[Category:Detection &amp;amp; Alarm]]&lt;/div&gt;</summary>