<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://fire-safety.academy/w/index.php?action=history&amp;feed=atom&amp;title=Fusible_link</id>
	<title>Fusible link - Revision history</title>
	<link rel="self" type="application/atom+xml" href="https://fire-safety.academy/w/index.php?action=history&amp;feed=atom&amp;title=Fusible_link"/>
	<link rel="alternate" type="text/html" href="https://fire-safety.academy/w/index.php?title=Fusible_link&amp;action=history"/>
	<updated>2026-11-21T22:34:44Z</updated>
	<subtitle>Revision history for this page on the wiki</subtitle>
	<generator>MediaWiki 1.43.11</generator>
	<entry>
		<id>https://fire-safety.academy/w/index.php?title=Fusible_link&amp;diff=9413&amp;oldid=prev</id>
		<title>Peter: Wiki review: corrected 8 errors: typo (6), grammar, markup (Claude Opus 5.5)</title>
		<link rel="alternate" type="text/html" href="https://fire-safety.academy/w/index.php?title=Fusible_link&amp;diff=9413&amp;oldid=prev"/>
		<updated>2026-11-15T23:47:14Z</updated>

		<summary type="html">&lt;p&gt;Wiki review: corrected 8 errors: typo (6), grammar, markup (Claude Opus 5.5)&lt;/p&gt;
&lt;table style=&quot;background-color: #fff; color: #202122;&quot; data-mw=&quot;interface&quot;&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;tr class=&quot;diff-title&quot; lang=&quot;en&quot;&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;← Older revision&lt;/td&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;Revision as of 00:47, 16 November 2026&lt;/td&gt;
				&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l1&quot;&gt;Line 1:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 1:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&#039;&#039;&#039;&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;Fusible &lt;/del&gt;link&#039;&#039;&#039; is a heat-sensitive mechanical element that releases a connected mechanism when heating causes its fusible connection to separate.&amp;lt;ref name=&quot;NFPA-§18.4,pp.18-59-18-61&quot;&amp;gt;Cote et al. (2008), §18.4, pp. 18-59–18-61.&amp;lt;/ref&amp;gt; The device responds to the temperature of its own sensing element. Heat must travel from the fire to the element before the release condition is reached; the operating temperature and thermal sensitivity therefore describe different aspects of its response. A link&#039;s nominal rating cannot by itself specify when it operates in a particular fire.&amp;lt;ref name=&quot;SMC-link&quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;A &lt;/ins&gt;&#039;&#039;&#039;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;fusible &lt;/ins&gt;link&#039;&#039;&#039; is a heat-sensitive mechanical element that releases a connected mechanism when heating causes its fusible connection to separate.&amp;lt;ref name=&quot;NFPA-§18.4,pp.18-59-18-61&quot;&amp;gt;Cote et al. (2008), §18.4, pp. 18-59–18-61.&amp;lt;/ref&amp;gt; The device responds to the temperature of its own sensing element. Heat must travel from the fire to the element before the release condition is reached; the operating temperature and thermal sensitivity therefore describe different aspects of its response. A link&#039;s nominal rating cannot by itself specify when it operates in a particular fire.&amp;lt;ref name=&quot;SMC-link&quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The released mechanism may open a vent or permit a closure to move; these are different protective actions, each requiring a defined sequence and suitable conditions. The National Fire Protection Association (NFPA) handbook distinguishes heat-operated release from smoke-responsive operation where smoke can affect an escape route before substantial heating occurs. Assessment therefore connects the release characteristic to the purpose of the controlled equipment.&amp;lt;ref name=&amp;quot;NFPA-link-lead&amp;quot;&amp;gt;Cote et al. (2008), §4.3, p. 4-84; §18.4, pp. 18-59–18-61.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The released mechanism may open a vent or permit a closure to move; these are different protective actions, each requiring a defined sequence and suitable conditions. The National Fire Protection Association (NFPA) handbook distinguishes heat-operated release from smoke-responsive operation where smoke can affect an escape route before substantial heating occurs. Assessment therefore connects the release characteristic to the purpose of the controlled equipment.&amp;lt;ref name=&amp;quot;NFPA-link-lead&amp;quot;&amp;gt;Cote et al. (2008), §4.3, p. 4-84; §18.4, pp. 18-59–18-61.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l6&quot;&gt;Line 6:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 6:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;A fusible link provides a local heat-operated release rather than a general indication of smoke. The NFPA handbook describes links used to initiate opening of heat vents and other protective mechanisms. Operation depends on heating of the link itself; the temperature of the surrounding gas and the temperature of the element need not be equal during a developing fire.&amp;lt;ref name=&amp;quot;NFPA-§18.4,pp.18-59-18-61&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;SMC-link&amp;quot;&amp;gt;Schifiliti et al. (2002), pp. 4-1–4-4.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;A fusible link provides a local heat-operated release rather than a general indication of smoke. The NFPA handbook describes links used to initiate opening of heat vents and other protective mechanisms. Operation depends on heating of the link itself; the temperature of the surrounding gas and the temperature of the element need not be equal during a developing fire.&amp;lt;ref name=&amp;quot;NFPA-§18.4,pp.18-59-18-61&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;SMC-link&amp;quot;&amp;gt;Schifiliti et al. (2002), pp. 4-1–4-4.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[[File:fse-fusible-link-v1.svg|thumb|upright=1.5|alt=Fusible link: heat-operated release and its limits, showing the relationships described in the text.|Heat-operated release and its limits in the assessment of &lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;Fusible &lt;/del&gt;link.]]&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[[File:fse-fusible-link-v1.svg|thumb|upright=1.5|alt=Fusible link: heat-operated release and its limits, showing the relationships described in the text.|Heat-operated release and its limits in the assessment of &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;a fusible &lt;/ins&gt;link.]]&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;A [[Fire damper|fire damper]] and a [[Fire door|fire door]] may use heat-operated release in particular applications. A [[Heat detector|heat detector]] is a related sensing device, but it can use other mechanisms and provide a signal to a control system. The [[Response time index|response time index]] describes thermal sensitivity in suitable heat-response models. It is not interchangeable with the element&amp;#039;s operating temperature.&amp;lt;ref name=&amp;quot;NFPA-§4.3,p.4-84&amp;quot;&amp;gt;Cote et al. (2008), §4.3, p. 4-84.&amp;lt;/ref&amp;gt;&amp;lt;ref name=&amp;quot;SMC-link&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;A [[Fire damper|fire damper]] and a [[Fire door|fire door]] may use heat-operated release in particular applications. A [[Heat detector|heat detector]] is a related sensing device, but it can use other mechanisms and provide a signal to a control system. The [[Response time index|response time index]] describes thermal sensitivity in suitable heat-response models. It is not interchangeable with the element&amp;#039;s operating temperature.&amp;lt;ref name=&amp;quot;NFPA-§4.3,p.4-84&amp;quot;&amp;gt;Cote et al. (2008), §4.3, p. 4-84.&amp;lt;/ref&amp;gt;&amp;lt;ref name=&amp;quot;SMC-link&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l15&quot;&gt;Line 15:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 15:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;A thermal element is one component of a protective sequence. Heating must reach the element, the link must release, and the connected equipment must move to its intended state. Each stage describes a different part of system performance. The NFPA handbook&amp;#039;s discussion of heat-operated vents illustrates why operation is associated with the developing fire and the location of the equipment.&amp;lt;ref name=&amp;quot;NFPA-release&amp;quot;&amp;gt;Cote et al. (2008), §18.4, pp. 18-59–18-61.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;A thermal element is one component of a protective sequence. Heating must reach the element, the link must release, and the connected equipment must move to its intended state. Each stage describes a different part of system performance. The NFPA handbook&amp;#039;s discussion of heat-operated vents illustrates why operation is associated with the developing fire and the location of the equipment.&amp;lt;ref name=&amp;quot;NFPA-release&amp;quot;&amp;gt;Cote et al. (2008), §18.4, pp. 18-59–18-61.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[[File:fse-fusible-link-v2.svg|thumb|upright=1.5|alt=Fusible link: release action and equipment dependencies, showing the relationships described in the text.|Release action and equipment dependencies in the assessment of &lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;Fusible &lt;/del&gt;link.]]&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[[File:fse-fusible-link-v2.svg|thumb|upright=1.5|alt=Fusible link: release action and equipment dependencies, showing the relationships described in the text.|Release action and equipment dependencies in the assessment of &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;a fusible &lt;/ins&gt;link.]]&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;A vent that opens discharges hot gases, while a door that closes restricts an opening. The same general principle of thermal release can therefore initiate opposite physical movements. The suitability of a link cannot be judged without identifying the controlled function. Its response must be interpreted within the complete arrangement rather than as an isolated temperature number.&amp;lt;ref name=&amp;quot;NFPA-release&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;NFPA-link-lead&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;A vent that opens discharges hot gases, while a door that closes restricts an opening. The same general principle of thermal release can therefore initiate opposite physical movements. The suitability of a link cannot be judged without identifying the controlled function. Its response must be interpreted within the complete arrangement rather than as an isolated temperature number.&amp;lt;ref name=&amp;quot;NFPA-release&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;NFPA-link-lead&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l47&quot;&gt;Line 47:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 47:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Transport from the fire to the sensing element ==&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Transport from the fire to the sensing element ==&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Hot gases rise in a plume and spread beneath a ceiling as a &lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;Ceiling &lt;/del&gt;jet. A detector in this flow receives heat from the moving gases. Both gas temperature and gas velocity affect the transfer of energy to the element. The International Fire Engineering Guidelines (IFEG, 2005) also identify the element&#039;s distance below the ceiling as relevant.&amp;lt;ref name=&quot;heatdetector_IFEG_2.7-2&quot;&amp;gt;Australian Building Codes Board et al. (2005), p. 2.7-2.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Hot gases rise in a plume and spread beneath a ceiling as a &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;ceiling &lt;/ins&gt;jet. A detector in this flow receives heat from the moving gases. Both gas temperature and gas velocity affect the transfer of energy to the element. The International Fire Engineering Guidelines (IFEG, 2005) also identify the element&#039;s distance below the ceiling as relevant.&amp;lt;ref name=&quot;heatdetector_IFEG_2.7-2&quot;&amp;gt;Australian Building Codes Board et al. (2005), p. 2.7-2.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The temperature and velocity are not uniform throughout the flow, and their values change with location relative to the fire and with depth below the ceiling. A detector placed outside the relevant hot flow does not receive the exposure assumed for a detector within it. Geometry is therefore part of the response calculation rather than a separate installation detail.&amp;lt;ref name=&amp;quot;heatdetector_IFEG_2.7-2&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;heatdetector_SMC_4-7&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The temperature and velocity are not uniform throughout the flow, and their values change with location relative to the fire and with depth below the ceiling. A detector placed outside the relevant hot flow does not receive the exposure assumed for a detector within it. Geometry is therefore part of the response calculation rather than a separate installation detail.&amp;lt;ref name=&amp;quot;heatdetector_IFEG_2.7-2&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;heatdetector_SMC_4-7&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l53&quot;&gt;Line 53:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 53:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Thermal lag is the delay caused by the sensing element taking time to heat. During rising gas temperature, the element can remain cooler than the surrounding gases. Consequently, the gas temperature at operation can exceed the detector&amp;#039;s nominal operating temperature. The rating applies to the element&amp;#039;s response, not to instantaneous equality between gas and element temperatures.&amp;lt;ref name=&amp;quot;heatdetector_N_12-3&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Thermal lag is the delay caused by the sensing element taking time to heat. During rising gas temperature, the element can remain cooler than the surrounding gases. Consequently, the gas temperature at operation can exceed the detector&amp;#039;s nominal operating temperature. The rating applies to the element&amp;#039;s response, not to instantaneous equality between gas and element temperatures.&amp;lt;ref name=&amp;quot;heatdetector_N_12-3&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The &lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;Detector &lt;/del&gt;activation time contains the effects of exposure and thermal response. A steady-exposure calculation begins when the assumed hot gases reach the element, so it does not automatically include the earlier transport of those gases from the fire. Schifiliti and colleagues explicitly identify this transport omission in the simplest steady ceiling-jet model.&amp;lt;ref name=&quot;heatdetector_SMC_4-7_4-8&quot;&amp;gt;Schifiliti et al. (2002), pp. 4-7–4-8.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;detector &lt;/ins&gt;activation time contains the effects of exposure and thermal response. A steady-exposure calculation begins when the assumed hot gases reach the element, so it does not automatically include the earlier transport of those gases from the fire. Schifiliti and colleagues explicitly identify this transport omission in the simplest steady ceiling-jet model.&amp;lt;ref name=&quot;heatdetector_SMC_4-7_4-8&quot;&amp;gt;Schifiliti et al. (2002), pp. 4-7–4-8.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Thermal response and response time index ==&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Thermal response and response time index ==&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l59&quot;&gt;Line 59:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 59:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;A common model treats the sensing element as a single uniform thermal mass. This is called the lumped-mass approximation. It assumes that temperature differences within the element can be neglected. The temperature then increases according to the heat transferred from the gas and the element&amp;#039;s thermal response.&amp;lt;ref name=&amp;quot;heatdetector_SMC_4-5_4-6&amp;quot;&amp;gt;Schifiliti et al. (2002), pp. 4-5–4-6.&amp;lt;/ref&amp;gt;&amp;lt;ref name=&amp;quot;heatdetector_N_12-6&amp;quot;&amp;gt;Iqbal and Salley (2004), p. 12-6.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;A common model treats the sensing element as a single uniform thermal mass. This is called the lumped-mass approximation. It assumes that temperature differences within the element can be neglected. The temperature then increases according to the heat transferred from the gas and the element&amp;#039;s thermal response.&amp;lt;ref name=&amp;quot;heatdetector_SMC_4-5_4-6&amp;quot;&amp;gt;Schifiliti et al. (2002), pp. 4-5–4-6.&amp;lt;/ref&amp;gt;&amp;lt;ref name=&amp;quot;heatdetector_N_12-6&amp;quot;&amp;gt;Iqbal and Salley (2004), p. 12-6.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The &lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;Response &lt;/del&gt;time index (RTI) expresses thermal sensitivity in this model. For a given gas exposure, a smaller RTI gives faster heating of the element. The governing equation relates the rate of element heating to gas velocity and the temperature difference. As the element approaches the gas temperature, that driving temperature difference becomes smaller.&amp;lt;ref name=&quot;heatdetector_SMC_4-6&quot;&amp;gt;Schifiliti et al. (2002), p. 4-6.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;response &lt;/ins&gt;time index (RTI) expresses thermal sensitivity in this model. For a given gas exposure, a smaller RTI gives faster heating of the element. The governing equation relates the rate of element heating to gas velocity and the temperature difference. As the element approaches the gas temperature, that driving temperature difference becomes smaller.&amp;lt;ref name=&quot;heatdetector_SMC_4-6&quot;&amp;gt;Schifiliti et al. (2002), p. 4-6.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&amp;lt;math display=&amp;quot;block&amp;quot;&amp;gt;\frac{dT_d}{dt}=\frac{\sqrt{u}}{\mathrm{RTI}}(T_g-T_d)&amp;lt;/math&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&amp;lt;math display=&amp;quot;block&amp;quot;&amp;gt;\frac{dT_d}{dt}=\frac{\sqrt{u}}{\mathrm{RTI}}(T_g-T_d)&amp;lt;/math&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l104&quot;&gt;Line 104:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 104:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Normal non-fire temperatures influence the selection of a thermal operating rating. NUREG-1805 discusses higher-temperature devices for locations where ordinary ambient conditions would otherwise cause premature operation. The relevant exposure is the temperature near the detector, including expected non-fire heat sources. A rating chosen without those conditions can produce unwanted alarms.&amp;lt;ref name=&amp;quot;heatdetector_N_12-1_12-3&amp;quot;&amp;gt;Iqbal and Salley (2004), pp. 12-1–12-3.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Normal non-fire temperatures influence the selection of a thermal operating rating. NUREG-1805 discusses higher-temperature devices for locations where ordinary ambient conditions would otherwise cause premature operation. The relevant exposure is the temperature near the detector, including expected non-fire heat sources. A rating chosen without those conditions can produce unwanted alarms.&amp;lt;ref name=&amp;quot;heatdetector_N_12-1_12-3&amp;quot;&amp;gt;Iqbal and Salley (2004), pp. 12-1–12-3.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[[File:fse-fusible-link-v3.svg|thumb|upright=1.5|alt=Fusible link: environmental effects and calculation limits, showing the relationships described in the text.|Environmental effects and calculation limits in the assessment of &lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;Fusible &lt;/del&gt;link.]]&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[[File:fse-fusible-link-v3.svg|thumb|upright=1.5|alt=Fusible link: environmental effects and calculation limits, showing the relationships described in the text.|Environmental effects and calculation limits in the assessment of &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;a fusible &lt;/ins&gt;link.]]&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The report&amp;#039;s simple ceiling-jet method assumes an unconfined flat ceiling and a fire away from walls and corners. It excludes a developed hot layer beneath the jet during the period of interest. Obstructions and irregular ceilings can undermine the assumed flow. The method also does not explicitly include direct radiant heating of the sensing element.&amp;lt;ref name=&amp;quot;heatdetector_N_12-10_12-11&amp;quot;&amp;gt;Iqbal and Salley (2004), pp. 12-10–12-11.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The report&amp;#039;s simple ceiling-jet method assumes an unconfined flat ceiling and a fire away from walls and corners. It excludes a developed hot layer beneath the jet during the period of interest. Obstructions and irregular ceilings can undermine the assumed flow. The method also does not explicitly include direct radiant heating of the sensing element.&amp;lt;ref name=&amp;quot;heatdetector_N_12-10_12-11&amp;quot;&amp;gt;Iqbal and Salley (2004), pp. 12-10–12-11.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l113&quot;&gt;Line 113:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 113:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The gas-flow calculation and the element-response calculation have separate limitations. Correctly integrating a thermal equation cannot compensate for an unsuitable gas temperature or velocity prediction. Conversely, suitable gas conditions do not establish the correct thermal model for every detector mechanism. The assessed geometry, fire development and device behaviour must all fit the chosen method.&amp;lt;ref name=&amp;quot;heatdetector_SMC_4-7_4-9&amp;quot;&amp;gt;Schifiliti et al. (2002), pp. 4-7–4-9.&amp;lt;/ref&amp;gt;&amp;lt;ref name=&amp;quot;heatdetector_N_12-10&amp;quot;&amp;gt;Iqbal and Salley (2004), p. 12-10.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The gas-flow calculation and the element-response calculation have separate limitations. Correctly integrating a thermal equation cannot compensate for an unsuitable gas temperature or velocity prediction. Conversely, suitable gas conditions do not establish the correct thermal model for every detector mechanism. The assessed geometry, fire development and device behaviour must all fit the chosen method.&amp;lt;ref name=&amp;quot;heatdetector_SMC_4-7_4-9&amp;quot;&amp;gt;Schifiliti et al. (2002), pp. 4-7–4-9.&amp;lt;/ref&amp;gt;&amp;lt;ref name=&amp;quot;heatdetector_N_12-10&amp;quot;&amp;gt;Iqbal and Salley (2004), p. 12-10.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;&lt;/del&gt;&lt;/div&gt;&lt;/td&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-added&quot;&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;== See also ==&lt;/del&gt;&lt;/div&gt;&lt;/td&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-added&quot;&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;&lt;/del&gt;&lt;/div&gt;&lt;/td&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-added&quot;&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;&lt;/del&gt;&lt;/div&gt;&lt;/td&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-added&quot;&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Notes ==&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Notes ==&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;

&lt;!-- diff cache key firesb_pjbsiy42-wiki_:diff:1.41:old-8792:rev-9413:php=table --&gt;
&lt;/table&gt;</summary>
		<author><name>Peter</name></author>
	</entry>
	<entry>
		<id>https://fire-safety.academy/w/index.php?title=Fusible_link&amp;diff=8792&amp;oldid=prev</id>
		<title>Thomas: Add SVG figures fse-fusible-link-v1.svg, fse-fusible-link-v2.svg, fse-fusible-link-v3.svg (list-6 visual plan)</title>
		<link rel="alternate" type="text/html" href="https://fire-safety.academy/w/index.php?title=Fusible_link&amp;diff=8792&amp;oldid=prev"/>
		<updated>2026-11-13T08:39:19Z</updated>

		<summary type="html">&lt;p&gt;Add SVG figures fse-fusible-link-v1.svg, fse-fusible-link-v2.svg, fse-fusible-link-v3.svg (list-6 visual plan)&lt;/p&gt;
&lt;table style=&quot;background-color: #fff; color: #202122;&quot; data-mw=&quot;interface&quot;&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;tr class=&quot;diff-title&quot; lang=&quot;en&quot;&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;← Older revision&lt;/td&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;Revision as of 09:39, 13 November 2026&lt;/td&gt;
				&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l6&quot;&gt;Line 6:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 6:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;A fusible link provides a local heat-operated release rather than a general indication of smoke. The NFPA handbook describes links used to initiate opening of heat vents and other protective mechanisms. Operation depends on heating of the link itself; the temperature of the surrounding gas and the temperature of the element need not be equal during a developing fire.&amp;lt;ref name=&amp;quot;NFPA-§18.4,pp.18-59-18-61&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;SMC-link&amp;quot;&amp;gt;Schifiliti et al. (2002), pp. 4-1–4-4.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;A fusible link provides a local heat-operated release rather than a general indication of smoke. The NFPA handbook describes links used to initiate opening of heat vents and other protective mechanisms. Operation depends on heating of the link itself; the temperature of the surrounding gas and the temperature of the element need not be equal during a developing fire.&amp;lt;ref name=&amp;quot;NFPA-§18.4,pp.18-59-18-61&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;SMC-link&amp;quot;&amp;gt;Schifiliti et al. (2002), pp. 4-1–4-4.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-deleted&quot;&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;[[File:fse-fusible-link-v1.svg|thumb|upright=1.5|alt=Fusible link: heat-operated release and its limits, showing the relationships described in the text.|Heat-operated release and its limits in the assessment of Fusible link.]]&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;A [[Fire damper|fire damper]] and a [[Fire door|fire door]] may use heat-operated release in particular applications. A [[Heat detector|heat detector]] is a related sensing device, but it can use other mechanisms and provide a signal to a control system. The [[Response time index|response time index]] describes thermal sensitivity in suitable heat-response models. It is not interchangeable with the element&amp;#039;s operating temperature.&amp;lt;ref name=&amp;quot;NFPA-§4.3,p.4-84&amp;quot;&amp;gt;Cote et al. (2008), §4.3, p. 4-84.&amp;lt;/ref&amp;gt;&amp;lt;ref name=&amp;quot;SMC-link&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;A [[Fire damper|fire damper]] and a [[Fire door|fire door]] may use heat-operated release in particular applications. A [[Heat detector|heat detector]] is a related sensing device, but it can use other mechanisms and provide a signal to a control system. The [[Response time index|response time index]] describes thermal sensitivity in suitable heat-response models. It is not interchangeable with the element&amp;#039;s operating temperature.&amp;lt;ref name=&amp;quot;NFPA-§4.3,p.4-84&amp;quot;&amp;gt;Cote et al. (2008), §4.3, p. 4-84.&amp;lt;/ref&amp;gt;&amp;lt;ref name=&amp;quot;SMC-link&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l14&quot;&gt;Line 14:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 15:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;A thermal element is one component of a protective sequence. Heating must reach the element, the link must release, and the connected equipment must move to its intended state. Each stage describes a different part of system performance. The NFPA handbook&amp;#039;s discussion of heat-operated vents illustrates why operation is associated with the developing fire and the location of the equipment.&amp;lt;ref name=&amp;quot;NFPA-release&amp;quot;&amp;gt;Cote et al. (2008), §18.4, pp. 18-59–18-61.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;A thermal element is one component of a protective sequence. Heating must reach the element, the link must release, and the connected equipment must move to its intended state. Each stage describes a different part of system performance. The NFPA handbook&amp;#039;s discussion of heat-operated vents illustrates why operation is associated with the developing fire and the location of the equipment.&amp;lt;ref name=&amp;quot;NFPA-release&amp;quot;&amp;gt;Cote et al. (2008), §18.4, pp. 18-59–18-61.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-deleted&quot;&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;[[File:fse-fusible-link-v2.svg|thumb|upright=1.5|alt=Fusible link: release action and equipment dependencies, showing the relationships described in the text.|Release action and equipment dependencies in the assessment of Fusible link.]]&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;A vent that opens discharges hot gases, while a door that closes restricts an opening. The same general principle of thermal release can therefore initiate opposite physical movements. The suitability of a link cannot be judged without identifying the controlled function. Its response must be interpreted within the complete arrangement rather than as an isolated temperature number.&amp;lt;ref name=&amp;quot;NFPA-release&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;NFPA-link-lead&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;A vent that opens discharges hot gases, while a door that closes restricts an opening. The same general principle of thermal release can therefore initiate opposite physical movements. The suitability of a link cannot be judged without identifying the controlled function. Its response must be interpreted within the complete arrangement rather than as an isolated temperature number.&amp;lt;ref name=&amp;quot;NFPA-release&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;NFPA-link-lead&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l102&quot;&gt;Line 102:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 104:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Normal non-fire temperatures influence the selection of a thermal operating rating. NUREG-1805 discusses higher-temperature devices for locations where ordinary ambient conditions would otherwise cause premature operation. The relevant exposure is the temperature near the detector, including expected non-fire heat sources. A rating chosen without those conditions can produce unwanted alarms.&amp;lt;ref name=&amp;quot;heatdetector_N_12-1_12-3&amp;quot;&amp;gt;Iqbal and Salley (2004), pp. 12-1–12-3.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Normal non-fire temperatures influence the selection of a thermal operating rating. NUREG-1805 discusses higher-temperature devices for locations where ordinary ambient conditions would otherwise cause premature operation. The relevant exposure is the temperature near the detector, including expected non-fire heat sources. A rating chosen without those conditions can produce unwanted alarms.&amp;lt;ref name=&amp;quot;heatdetector_N_12-1_12-3&amp;quot;&amp;gt;Iqbal and Salley (2004), pp. 12-1–12-3.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-deleted&quot;&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;[[File:fse-fusible-link-v3.svg|thumb|upright=1.5|alt=Fusible link: environmental effects and calculation limits, showing the relationships described in the text.|Environmental effects and calculation limits in the assessment of Fusible link.]]&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The report&amp;#039;s simple ceiling-jet method assumes an unconfined flat ceiling and a fire away from walls and corners. It excludes a developed hot layer beneath the jet during the period of interest. Obstructions and irregular ceilings can undermine the assumed flow. The method also does not explicitly include direct radiant heating of the sensing element.&amp;lt;ref name=&amp;quot;heatdetector_N_12-10_12-11&amp;quot;&amp;gt;Iqbal and Salley (2004), pp. 12-10–12-11.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The report&amp;#039;s simple ceiling-jet method assumes an unconfined flat ceiling and a fire away from walls and corners. It excludes a developed hot layer beneath the jet during the period of interest. Obstructions and irregular ceilings can undermine the assumed flow. The method also does not explicitly include direct radiant heating of the sensing element.&amp;lt;ref name=&amp;quot;heatdetector_N_12-10_12-11&amp;quot;&amp;gt;Iqbal and Salley (2004), pp. 12-10–12-11.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;/table&gt;</summary>
		<author><name>Thomas</name></author>
	</entry>
	<entry>
		<id>https://fire-safety.academy/w/index.php?title=Fusible_link&amp;diff=4117&amp;oldid=prev</id>
		<title>Linda: Source and style review: Fusible link (written by GPT-6)</title>
		<link rel="alternate" type="text/html" href="https://fire-safety.academy/w/index.php?title=Fusible_link&amp;diff=4117&amp;oldid=prev"/>
		<updated>2026-11-07T22:15:05Z</updated>

		<summary type="html">&lt;p&gt;Source and style review: Fusible link (written by GPT-6)&lt;/p&gt;
&lt;table style=&quot;background-color: #fff; color: #202122;&quot; data-mw=&quot;interface&quot;&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;tr class=&quot;diff-title&quot; lang=&quot;en&quot;&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;← Older revision&lt;/td&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;Revision as of 23:15, 7 November 2026&lt;/td&gt;
				&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l1&quot;&gt;Line 1:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 1:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&#039;&#039;&#039;Fusible link&#039;&#039;&#039; is a heat-sensitive mechanical element that releases a connected mechanism when heating causes its fusible connection to separate.&amp;lt;ref name=&quot;NFPA-§18.4,pp.18-59-18-61&quot;&amp;gt;Cote et al. (2008), §18.4, pp. 18-59–18-61.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&#039;&#039;&#039;Fusible link&#039;&#039;&#039; is a heat-sensitive mechanical element that releases a connected mechanism when heating causes its fusible connection to separate.&amp;lt;ref name=&quot;NFPA-§18.4,pp.18-59-18-61&quot;&amp;gt;Cote et al. (2008), §18.4, pp. 18-59–18-61.&amp;lt;/ref&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;&amp;gt; The device responds to the temperature of its own sensing element. Heat must travel from the fire to the element before the release condition is reached; the operating temperature and thermal sensitivity therefore describe different aspects of its response. A link&#039;s nominal rating cannot by itself specify when it operates in a particular fire.&amp;lt;ref name=&quot;SMC-link&quot; /&lt;/ins&gt;&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;The device responds to the temperature of its own sensing element. Heat must travel from the fire to the element before the release condition is reached; the operating temperature and thermal sensitivity therefore describe different aspects of its response. A link&#039;s nominal rating cannot by itself specify when it operates in a particular fire.&amp;lt;ref name=&quot;SMC-link&quot; /&amp;gt;&lt;/del&gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The released mechanism may open a vent or permit a closure to move; these are different protective actions, each requiring a defined sequence and suitable conditions. The &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;National Fire Protection Association (&lt;/ins&gt;NFPA&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;) &lt;/ins&gt;handbook distinguishes heat-operated release from smoke-responsive operation where smoke can affect an escape route before substantial heating occurs. Assessment therefore connects the release characteristic to the purpose of the controlled equipment.&amp;lt;ref name=&quot;NFPA-link-lead&quot;&amp;gt;Cote et al. (2008), §4.3, p. 4-84; §18.4, pp. 18-59–18-61.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt; &lt;/div&gt;&lt;/td&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-added&quot;&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The released mechanism may open a vent or permit a closure to move; these are different protective actions, each requiring a defined sequence and suitable conditions. The NFPA handbook distinguishes heat-operated release from smoke-responsive operation where smoke can affect an escape route before substantial heating occurs. Assessment therefore connects the release characteristic to the purpose of the controlled equipment.&amp;lt;ref name=&quot;NFPA-link-lead&quot;&amp;gt;Cote et al. (2008), §4.3, p. 4-84; §18.4, pp. 18-59–18-61.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-added&quot;&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Heat-operated release and its limits ==&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Heat-operated release and its limits ==&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l11&quot;&gt;Line 11:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 9:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;A [[Fire damper|fire damper]] and a [[Fire door|fire door]] may use heat-operated release in particular applications. A [[Heat detector|heat detector]] is a related sensing device, but it can use other mechanisms and provide a signal to a control system. The [[Response time index|response time index]] describes thermal sensitivity in suitable heat-response models. It is not interchangeable with the element&amp;#039;s operating temperature.&amp;lt;ref name=&amp;quot;NFPA-§4.3,p.4-84&amp;quot;&amp;gt;Cote et al. (2008), §4.3, p. 4-84.&amp;lt;/ref&amp;gt;&amp;lt;ref name=&amp;quot;SMC-link&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;A [[Fire damper|fire damper]] and a [[Fire door|fire door]] may use heat-operated release in particular applications. A [[Heat detector|heat detector]] is a related sensing device, but it can use other mechanisms and provide a signal to a control system. The [[Response time index|response time index]] describes thermal sensitivity in suitable heat-response models. It is not interchangeable with the element&amp;#039;s operating temperature.&amp;lt;ref name=&amp;quot;NFPA-§4.3,p.4-84&amp;quot;&amp;gt;Cote et al. (2008), §4.3, p. 4-84.&amp;lt;/ref&amp;gt;&amp;lt;ref name=&amp;quot;SMC-link&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;A [[Draft curtain|draft curtain]] and a [[Self-closing door|self-closing door]] also require their own intended operating sequence. The handbook warns that thermal release may occur after smoke has already affected a protected route. The release condition, the connected mechanism and the required fire-safety function therefore remain distinct. No universal smoke-protection performance follows from the presence of a fusible link.&amp;lt;ref name=&quot;NFPA-§4.3,p.4-84&quot; /&amp;gt;&amp;lt;ref name=&quot;NFPA-§18.4,pp.18-59-18-61&quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;A [[Draft curtain|draft curtain]] and a [[Self-closing door|self-closing door]] also require their own intended operating sequence. The handbook warns that thermal release may occur after smoke has already affected a protected route. The release condition, the connected mechanism and the required fire-safety function therefore remain distinct. No universal smoke-protection performance follows from the presence of a fusible link.&amp;lt;ref name=&quot;NFPA-§4.3,p.4-84&quot; /&amp;gt;&amp;lt;ref name=&quot;NFPA-§18.4,pp.18-59-18-61&quot; /&amp;gt; The released link and the mechanism it controls therefore require separate descriptions of thermal response and successful movement.&amp;lt;ref name=&quot;NFPA-link-lead&quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt; &lt;/div&gt;&lt;/td&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-added&quot;&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The released link and the mechanism it controls therefore require separate descriptions of thermal response and successful movement.&amp;lt;ref name=&quot;NFPA-link-lead&quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-added&quot;&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Release action and equipment dependencies ==&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Release action and equipment dependencies ==&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;A thermal element is one component of a protective sequence. Heating must reach the element, the link must release, and the connected equipment must move to its intended state&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;; each &lt;/del&gt;stage describes a different part of system performance. The NFPA handbook&#039;s discussion of heat-operated vents illustrates why operation is associated with the developing fire and the location of the equipment.&amp;lt;ref name=&quot;NFPA-release&quot;&amp;gt;Cote et al. (2008), §18.4, pp. 18-59–18-61.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;A thermal element is one component of a protective sequence. Heating must reach the element, the link must release, and the connected equipment must move to its intended state&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;. Each &lt;/ins&gt;stage describes a different part of system performance. The NFPA handbook&#039;s discussion of heat-operated vents illustrates why operation is associated with the developing fire and the location of the equipment.&amp;lt;ref name=&quot;NFPA-release&quot;&amp;gt;Cote et al. (2008), §18.4, pp. 18-59–18-61.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;A vent that opens discharges hot gases, while a door that closes restricts an opening. The same general principle of thermal release can therefore initiate opposite physical movements. The suitability of a link cannot be judged without identifying the controlled function. Its response must be interpreted within the complete arrangement rather than as an isolated temperature number.&amp;lt;ref name=&amp;quot;NFPA-release&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;NFPA-link-lead&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;A vent that opens discharges hot gases, while a door that closes restricts an opening. The same general principle of thermal release can therefore initiate opposite physical movements. The suitability of a link cannot be judged without identifying the controlled function. Its response must be interpreted within the complete arrangement rather than as an isolated temperature number.&amp;lt;ref name=&amp;quot;NFPA-release&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;NFPA-link-lead&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l93&quot;&gt;Line 93:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 89:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Worked example under constant exposure ==&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Worked example under constant exposure ==&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The SFPE Handbook&#039;s second example uses the gas conditions calculated for a 4 m² kerosene pool beneath a flat ceiling. The ceiling is 6 m above the fire and the detector is 6 m horizontally from the plume centre. The ambient temperature is 20 °C. Its calculated exposure is a gas temperature of 153 °C and a velocity of 2.4 m/s.&amp;lt;ref name=&quot;heatdetector_SMC_4-8&quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;Society of Fire Protection Engineers (&lt;/ins&gt;SFPE&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;) &lt;/ins&gt;Handbook&#039;s second example uses the gas conditions calculated for a 4 m² kerosene pool beneath a flat ceiling. The ceiling is 6 m above the fire and the detector is 6 m horizontally from the plume centre. The ambient temperature is 20 °C. Its calculated exposure is a gas temperature of 153 °C and a velocity of 2.4 m/s.&amp;lt;ref name=&quot;heatdetector_SMC_4-8&quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The example detector has an RTI of 55 m&amp;lt;sup&amp;gt;1/2&amp;lt;/sup&amp;gt;s&amp;lt;sup&amp;gt;1/2&amp;lt;/sup&amp;gt; and an operating temperature of 57 °C. Substituting those values gives an exposure response time of approximately 11.6 s. Rounded upwards to whole seconds, the required time is 12 s. This reproduces the response reported in the handbook example.&amp;lt;ref name=&amp;quot;heatdetector_SMC_4-8&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The example detector has an RTI of 55 m&amp;lt;sup&amp;gt;1/2&amp;lt;/sup&amp;gt;s&amp;lt;sup&amp;gt;1/2&amp;lt;/sup&amp;gt; and an operating temperature of 57 °C. Substituting those values gives an exposure response time of approximately 11.6 s. Rounded upwards to whole seconds, the required time is 12 s. This reproduces the response reported in the handbook example.&amp;lt;ref name=&amp;quot;heatdetector_SMC_4-8&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;

&lt;!-- diff cache key firesb_pjbsiy42-wiki_:diff:1.41:old-4001:rev-4117:php=table --&gt;
&lt;/table&gt;</summary>
		<author><name>Linda</name></author>
	</entry>
	<entry>
		<id>https://fire-safety.academy/w/index.php?title=Fusible_link&amp;diff=4001&amp;oldid=prev</id>
		<title>Linda: Source and style review: Fusible link (written by GPT-6)</title>
		<link rel="alternate" type="text/html" href="https://fire-safety.academy/w/index.php?title=Fusible_link&amp;diff=4001&amp;oldid=prev"/>
		<updated>2026-11-07T22:02:58Z</updated>

		<summary type="html">&lt;p&gt;Source and style review: Fusible link (written by GPT-6)&lt;/p&gt;
&lt;a href=&quot;https://fire-safety.academy/w/index.php?title=Fusible_link&amp;amp;diff=4001&amp;amp;oldid=2982&quot;&gt;Show changes&lt;/a&gt;</summary>
		<author><name>Linda</name></author>
	</entry>
	<entry>
		<id>https://fire-safety.academy/w/index.php?title=Fusible_link&amp;diff=2982&amp;oldid=prev</id>
		<title>Linda: New FSE wiki article: Fusible link (written by GPT-6)</title>
		<link rel="alternate" type="text/html" href="https://fire-safety.academy/w/index.php?title=Fusible_link&amp;diff=2982&amp;oldid=prev"/>
		<updated>2026-11-07T21:04:29Z</updated>

		<summary type="html">&lt;p&gt;New FSE wiki article: Fusible link (written by GPT-6)&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;&amp;#039;&amp;#039;&amp;#039;Fusible link&amp;#039;&amp;#039;&amp;#039; is a heat-sensitive mechanical element that releases a connected mechanism when heating causes its fusible connection to separate.&amp;lt;ref name=&amp;quot;NFPA-§18.4,pp.18-59-18-61&amp;quot;&amp;gt;Cote et al. (2008), §18.4, pp. 18-59–18-61.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
The device responds to the temperature of its own sensing element. Heat must travel from the fire to the element before the release condition is reached. The operating temperature and thermal sensitivity therefore describe different aspects of its response. A link&amp;#039;s nominal rating cannot by itself specify when it operates in a particular fire.&amp;lt;ref name=&amp;quot;SMC-link&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
The released mechanism may open a vent or permit a closure to move. These are different protective actions, each requiring a defined sequence and suitable conditions. The NFPA handbook distinguishes heat-operated release from smoke-responsive operation where smoke can affect an escape route before substantial heating occurs. Assessment therefore connects the release characteristic to the purpose of the controlled equipment.&amp;lt;ref name=&amp;quot;NFPA-link-lead&amp;quot;&amp;gt;Cote et al. (2008), §4.3, p. 4-84; §18.4, pp. 18-59–18-61.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== Heat-operated release and its limits ==&lt;br /&gt;
&lt;br /&gt;
A fusible link provides a local heat-operated release rather than a general indication of smoke. The NFPA handbook describes links used to initiate opening of heat vents and other protective mechanisms. Operation depends on heating of the link itself. The temperature of the surrounding gas and the temperature of the element need not be equal during a developing fire.&amp;lt;ref name=&amp;quot;NFPA-§18.4,pp.18-59-18-61&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;SMC-link&amp;quot;&amp;gt;Schifiliti et al. (2002), pp. 4-1–4-4.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
A [[Fire damper|fire damper]] and a [[Fire door|fire door]] may use heat-operated release in particular applications. A [[Heat detector|heat detector]] is a related sensing device, but it can use other mechanisms and provide a signal to a control system. The [[Response time index|response time index]] describes thermal sensitivity in suitable heat-response models. It is not interchangeable with the element&amp;#039;s operating temperature.&amp;lt;ref name=&amp;quot;NFPA-§4.3,p.4-84&amp;quot;&amp;gt;Cote et al. (2008), §4.3, p. 4-84.&amp;lt;/ref&amp;gt;&amp;lt;ref name=&amp;quot;SMC-link&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
A [[Draft curtain|draft curtain]] and a [[Self-closing door|self-closing door]] also require their own intended operating sequence. The handbook warns that thermal release may occur after smoke has already affected a protected route. The release condition, the connected mechanism and the required fire-safety function therefore remain distinct. No universal smoke-protection performance follows from the presence of a fusible link.&amp;lt;ref name=&amp;quot;NFPA-§4.3,p.4-84&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;NFPA-§18.4,pp.18-59-18-61&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
The released link and the mechanism it controls therefore require separate descriptions of thermal response and successful movement.&amp;lt;ref name=&amp;quot;NFPA-link-lead&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== Release action and equipment dependencies ==&lt;br /&gt;
&lt;br /&gt;
A thermal element is one component of a protective sequence. Heating must reach the element, the link must release, and the connected equipment must move to its intended state. Each stage describes a different part of system performance. The NFPA handbook&amp;#039;s discussion of heat-operated vents illustrates why operation is associated with the developing fire and the location of the equipment.&amp;lt;ref name=&amp;quot;NFPA-release&amp;quot;&amp;gt;Cote et al. (2008), §18.4, pp. 18-59–18-61.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
A vent that opens discharges hot gases, while a door that closes restricts an opening. The same general principle of thermal release can therefore initiate opposite physical movements. The suitability of a link cannot be judged without identifying the controlled function. Its response must be interpreted within the complete arrangement rather than as an isolated temperature number.&amp;lt;ref name=&amp;quot;NFPA-release&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;NFPA-link-lead&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Smoke presents a different timing problem from direct heating. A space can receive smoke before a link becomes hot enough to release. The NFPA handbook discusses this limitation in the protection of exit facilities. An appropriate assessment distinguishes the time when smoke threatens the route from the later thermal response of a heat-operated element.&amp;lt;ref name=&amp;quot;NFPA-link-lead&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
A detector-operated release adds a control-system path between sensing and movement. The handbook describes alarm interfaces that release doors held open for normal circulation. These systems introduce dependencies on the initiating device, interface and controlled mechanism. They are not equivalent to a link located directly in the hot gas stream.&amp;lt;ref name=&amp;quot;NFPA-interface&amp;quot;&amp;gt;Cote et al. (2008), §14.4, pp. 14-46–14-47.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Construction and commissioning establish whether the intended protection has actually been provided. The 2005 International Fire Engineering Guidelines distinguish the integrity of barriers from conformity of materials and components with their specifications. They also identify the operation of moving closures as a separate commissioning concern. A visual inspection of a finished surface cannot establish every one of those conditions.&amp;lt;ref name=&amp;quot;IFEG-commission&amp;quot;&amp;gt;Australian Building Codes Board et al. (2005), p. 1.6-9.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Building alterations can disturb protection after the original work has been completed. A new cable route, repaired lining or changed opening can affect a boundary whose purpose is not obvious from within one room. The guidelines identify this vulnerability in passive components. Continued identification of the separating construction makes the implications of a local alteration visible within the wider building arrangement.&amp;lt;ref name=&amp;quot;IFEG-commission&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
The same guidance distinguishes fixed barriers from operable closures when discussing maintenance. A fixed wall and an automatically closing door do not require identical checks. Operational tests provide information that a product label cannot supply. Records preserve the conditions inspected and the outcome of the check, allowing subsequent work to be understood against the established fire-safety function.&amp;lt;ref name=&amp;quot;IFEG-commission&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
These checks concern continued conformity with the intended arrangement. They do not replace the test evidence used to establish the original performance claim. Conversely, a successful laboratory test does not demonstrate that a later installation remains complete. Both forms of evidence are necessary to connect the rated system with the building in service.&amp;lt;ref name=&amp;quot;IFEG-commission&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== Fixed-temperature and rate-of-rise mechanisms ==&lt;br /&gt;
&lt;br /&gt;
A fusible fixed-temperature element uses a material that melts at its operating temperature. Melting releases a mechanism or closes contacts to initiate the signal; the fusible element is not restored simply by cooling. NUREG-1805 distinguishes this arrangement from bimetallic devices that can return to their original condition after heating stops.&amp;lt;ref name=&amp;quot;heatdetector_N_12-3&amp;quot;&amp;gt;Iqbal and Salley (2004), p. 12-3.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Bimetallic devices use metals with different thermal expansion behaviour: a strip can bend, or a shaped disc can reverse curvature when heated. This movement operates the electrical contacts. Electronic thermal detectors instead monitor a temperature-dependent electrical resistance and can apply a fixed-temperature or rate-of-rise criterion.&amp;lt;ref name=&amp;quot;heatdetector_N_12-3__12-5&amp;quot;&amp;gt;Iqbal and Salley (2004), pp. 12-3, 12-5.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
A pneumatic rate-of-rise detector uses expanding air in a chamber or tube: a small vent accommodates gradual changes, while sufficiently rapid heating produces pressure faster than it can escape. That pressure operates a diaphragm and contacts. NUREG-1805 describes example operating rates around 7–8 °C per minute; this is not a universal threshold for every product.&amp;lt;ref name=&amp;quot;heatdetector_N_12-4&amp;quot;&amp;gt;Iqbal and Salley (2004), p. 12-4.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Heat detection can cover a compact point or extend along a line. NUREG-1805 describes a continuous cable in which heat-sensitive insulation separates two conductors until the operating condition is reached. Another arrangement uses temperature-dependent electrical conduction within the cable assembly. Pneumatic line detection instead responds to expansion within a length of tubing. The exposed length and the distribution of heating then affect the signal.&amp;lt;ref name=&amp;quot;heatdetector_N_12-3__12-5&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Combination devices can include both fixed-temperature and rate-of-rise functions: the rapid-rise element can respond during fast heating, while the fixed-temperature function remains relevant during slower heating. Rate-compensated devices use differential expansion to reduce the effect of thermal lag. Their internal mechanisms differ from a simple element represented by one uniform temperature.&amp;lt;ref name=&amp;quot;heatdetector_N_12-4_12-5&amp;quot;&amp;gt;Iqbal and Salley (2004), pp. 12-4–12-5.&amp;lt;/ref&amp;gt;&amp;lt;ref name=&amp;quot;heatdetector_SMC_4-7&amp;quot;&amp;gt;Schifiliti, Meacham, and Custer (2002), p. 4-7.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== Transport from the fire to the sensing element ==&lt;br /&gt;
&lt;br /&gt;
Hot gases rise in a plume and spread beneath a ceiling as a Ceiling jet. A detector in this flow receives heat from the moving gases. Both gas temperature and gas velocity affect the transfer of energy to the element. The International Fire Engineering Guidelines (IFEG, 2005) also identify the element&amp;#039;s distance below the ceiling as relevant.&amp;lt;ref name=&amp;quot;heatdetector_IFEG_2.7-2&amp;quot;&amp;gt;Australian Building Codes Board et al. (2005), p. 2.7-2.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
The temperature and velocity are not uniform throughout the flow, and their values change with location relative to the fire and with depth below the ceiling. A detector placed outside the relevant hot flow does not receive the exposure assumed for a detector within it. Geometry is therefore part of the response calculation rather than a separate installation detail.&amp;lt;ref name=&amp;quot;heatdetector_IFEG_2.7-2&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;heatdetector_SMC_4-7&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Thermal lag is the delay caused by the sensing element taking time to heat. During rising gas temperature, the element can remain cooler than the surrounding gases. Consequently, the gas temperature at operation can exceed the detector&amp;#039;s nominal operating temperature. The rating applies to the element&amp;#039;s response, not to instantaneous equality between gas and element temperatures.&amp;lt;ref name=&amp;quot;heatdetector_N_12-3&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
The Detector activation time contains the effects of exposure and thermal response. A steady-exposure calculation begins when the assumed hot gases reach the element, so it does not automatically include the earlier transport of those gases from the fire. Schifiliti and colleagues explicitly identify this transport omission in the simplest steady ceiling-jet model.&amp;lt;ref name=&amp;quot;heatdetector_SMC_4-7_4-8&amp;quot;&amp;gt;Schifiliti, Meacham, and Custer (2002), pp. 4-7–4-8.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== Thermal response and response time index ==&lt;br /&gt;
&lt;br /&gt;
A common model treats the sensing element as a single uniform thermal mass. This is called the lumped-mass approximation. It assumes that temperature differences within the element can be neglected. The temperature then increases according to the heat transferred from the gas and the element&amp;#039;s thermal response.&amp;lt;ref name=&amp;quot;heatdetector_SMC_4-5_4-6&amp;quot;&amp;gt;Schifiliti, Meacham, and Custer (2002), pp. 4-5–4-6.&amp;lt;/ref&amp;gt;&amp;lt;ref name=&amp;quot;heatdetector_N_12-6&amp;quot;&amp;gt;Iqbal and Salley (2004), p. 12-6.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
The Response time index (RTI) expresses thermal sensitivity in this model. For a given gas exposure, a smaller RTI gives faster heating of the element. The governing equation relates the rate of element heating to gas velocity and the temperature difference. As the element approaches the gas temperature, that driving temperature difference becomes smaller.&amp;lt;ref name=&amp;quot;heatdetector_SMC_4-6&amp;quot;&amp;gt;Schifiliti, Meacham, and Custer (2002), p. 4-6.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;math display=&amp;quot;block&amp;quot;&amp;gt;\frac{dT_d}{dt}=\frac{\sqrt{u}}{\mathrm{RTI}}(T_g-T_d)&amp;lt;/math&amp;gt;&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
! Symbol !! Description !! Unit&lt;br /&gt;
|-&lt;br /&gt;
| &amp;lt;math&amp;gt;T_d&amp;lt;/math&amp;gt; || Temperature of the detector&amp;#039;s sensing element || °C&lt;br /&gt;
|-&lt;br /&gt;
| &amp;lt;math&amp;gt;T_g&amp;lt;/math&amp;gt; || Gas temperature at the sensing element || °C&lt;br /&gt;
|-&lt;br /&gt;
| &amp;lt;math&amp;gt;t&amp;lt;/math&amp;gt; || Time measured from the start of the assumed exposure || s&lt;br /&gt;
|-&lt;br /&gt;
| &amp;lt;math&amp;gt;u&amp;lt;/math&amp;gt; || Gas velocity at the element || m/s&lt;br /&gt;
|-&lt;br /&gt;
| &amp;lt;math&amp;gt;\mathrm{RTI}&amp;lt;/math&amp;gt; || Response time index || m&amp;lt;sup&amp;gt;1/2&amp;lt;/sup&amp;gt;s&amp;lt;sup&amp;gt;1/2&amp;lt;/sup&amp;gt;&lt;br /&gt;
|-&lt;br /&gt;
| &amp;lt;math&amp;gt;T_a&amp;lt;/math&amp;gt; || Initial element temperature, equal to ambient in this model || °C&lt;br /&gt;
|-&lt;br /&gt;
| &amp;lt;math&amp;gt;T_r&amp;lt;/math&amp;gt; || Element temperature required for operation || °C&lt;br /&gt;
|-&lt;br /&gt;
| &amp;lt;math&amp;gt;t_r&amp;lt;/math&amp;gt; || Time to operation under the assumed constant exposure || s&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
For constant gas temperature and velocity, the equation can be integrated to obtain the time to reach the operating temperature. The expression below uses the natural logarithm, and it applies when the element starts at ambient temperature and the gas temperature exceeds the operating threshold. It represents fixed-temperature response under the stated thermal assumptions.&amp;lt;ref name=&amp;quot;heatdetector_SMC_4-8&amp;quot;&amp;gt;Schifiliti, Meacham, and Custer (2002), p. 4-8.&amp;lt;/ref&amp;gt;&amp;lt;ref name=&amp;quot;heatdetector_N_12-6&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;math display=&amp;quot;block&amp;quot;&amp;gt;t_r=\frac{\mathrm{RTI}}{\sqrt{u}}\ln\left(\frac{T_g-T_a}{T_g-T_r}\right)&amp;lt;/math&amp;gt;&lt;br /&gt;
&lt;br /&gt;
The ratio inside the logarithm uses temperature differences, so consistent Celsius differences can be used. The response time becomes longer when the operating temperature approaches the imposed gas temperature. If the gas never becomes hot enough, this constant-exposure model does not predict threshold operation. A nominal temperature rating alone is therefore insufficient to calculate a response time.&amp;lt;ref name=&amp;quot;heatdetector_SMC_4-6_4-8&amp;quot;&amp;gt;Schifiliti, Meacham, and Custer (2002), pp. 4-6–4-8.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== Worked example under constant exposure ==&lt;br /&gt;
&lt;br /&gt;
The SFPE Handbook&amp;#039;s second example uses the gas conditions calculated for a 4 m² kerosene pool beneath a flat ceiling. The ceiling is 6 m above the fire and the detector is 6 m horizontally from the plume centre. The ambient temperature is 20 °C. Its calculated exposure is a gas temperature of 153 °C and a velocity of 2.4 m/s.&amp;lt;ref name=&amp;quot;heatdetector_SMC_4-8&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
The example detector has an RTI of 55 m&amp;lt;sup&amp;gt;1/2&amp;lt;/sup&amp;gt;s&amp;lt;sup&amp;gt;1/2&amp;lt;/sup&amp;gt; and an operating temperature of 57 °C. Substituting those values gives an exposure response time of approximately 11.6 s. Rounded upwards to whole seconds, the required time is 12 s. This reproduces the response reported in the handbook example.&amp;lt;ref name=&amp;quot;heatdetector_SMC_4-8&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;math display=&amp;quot;block&amp;quot;&amp;gt;t_r=\frac{55}{\sqrt{2.4}}\ln\left(\frac{153-20}{153-57}\right)\ \mathrm{s}\approx12\ \mathrm{s}&amp;lt;/math&amp;gt;&lt;br /&gt;
&lt;br /&gt;
This is the time for the specified element to heat under the specified exposure. It is not a claim that a detector will alarm 12 s after every kerosene fire ignites. The example assumes the calculated gas conditions are already present and remain constant. Fire growth, transport to the detector and subsequent alarm-system delays require separate treatment.&amp;lt;ref name=&amp;quot;heatdetector_SMC_4-2_4-3__4-8&amp;quot;&amp;gt;Schifiliti, Meacham, and Custer (2002), pp. 4-2–4-3, 4-8.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
For growing fires, Schifiliti and colleagues divide the changing exposure into short time intervals. The updated element temperature is carried from one interval into the next. Gas temperature and velocity can then change as the fire grows. This approach preserves the element&amp;#039;s heating history instead of restarting the calculation at ambient temperature each time.&amp;lt;ref name=&amp;quot;heatdetector_SMC_4-8_4-9&amp;quot;&amp;gt;Schifiliti, Meacham, and Custer (2002), pp. 4-8–4-9.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== Environmental effects and calculation limits ==&lt;br /&gt;
&lt;br /&gt;
Normal non-fire temperatures influence the selection of a thermal operating rating. NUREG-1805 discusses higher-temperature devices for locations where ordinary ambient conditions would otherwise cause premature operation. The relevant exposure is the temperature near the detector, including expected non-fire heat sources. A rating chosen without those conditions can produce unwanted alarms.&amp;lt;ref name=&amp;quot;heatdetector_N_12-1_12-3&amp;quot;&amp;gt;Iqbal and Salley (2004), pp. 12-1–12-3.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
The report&amp;#039;s simple ceiling-jet method assumes an unconfined flat ceiling and a fire away from walls and corners. It excludes a developed hot layer beneath the jet during the period of interest. Obstructions and irregular ceilings can undermine the assumed flow. The method also does not explicitly include direct radiant heating of the sensing element.&amp;lt;ref name=&amp;quot;heatdetector_N_12-10_12-11&amp;quot;&amp;gt;Iqbal and Salley (2004), pp. 12-10–12-11.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
The assumption of a constant RTI is itself an approximation. Schifiliti and colleagues discuss the complex gas flow around irregular detector shapes and the possibility of heat conduction into supporting parts. A plunge test may involve conditions in which those heat losses are relatively small, but their importance can differ during the slower flows of an actual fire. A thermal parameter obtained from one test condition therefore needs an appropriate range of application.&amp;lt;ref name=&amp;quot;heatdetector_SMC_4-6&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Modelled response after another protective device operates also requires care. The handbook notes that its basic calculations do not account for sprinkler cooling when predicting subsequent detector or sprinkler activation. The first operating device can change the environment experienced by other devices. Their later responses cannot automatically be inferred by continuing the original unsuppressed exposure unchanged.&amp;lt;ref name=&amp;quot;heatdetector_SMC_4-7&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
The gas-flow calculation and the element-response calculation have separate limitations. Correctly integrating a thermal equation cannot compensate for an unsuitable gas temperature or velocity prediction. Conversely, suitable gas conditions do not establish the correct thermal model for every detector mechanism. The assessed geometry, fire development and device behaviour must all fit the chosen method.&amp;lt;ref name=&amp;quot;heatdetector_SMC_4-7_4-9&amp;quot;&amp;gt;Schifiliti, Meacham, and Custer (2002), pp. 4-7–4-9.&amp;lt;/ref&amp;gt;&amp;lt;ref name=&amp;quot;heatdetector_N_12-10&amp;quot;&amp;gt;Iqbal and Salley (2004), p. 12-10.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== See also ==&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
== Notes ==&lt;br /&gt;
&lt;br /&gt;
&amp;lt;references /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== References ==&lt;br /&gt;
&lt;br /&gt;
* Australian Building Codes Board, National Research Council of Canada, International Code Council, &amp;amp; Department of Building and Housing New Zealand. (2005). &amp;#039;&amp;#039;International fire engineering guidelines&amp;#039;&amp;#039;. Australian Building Codes Board.&lt;br /&gt;
* Cote, A. E., Grant, C. C., Hall, J. R., Jr., &amp;amp; Solomon, R. E. (Eds.). (2008). &amp;#039;&amp;#039;Fire protection handbook&amp;#039;&amp;#039; (20th ed.). National Fire Protection Association.&lt;br /&gt;
* Iqbal, N., &amp;amp; Salley, M. H. (2004). &amp;#039;&amp;#039;Fire dynamics tools (FDTs): Quantitative fire hazard analysis methods for the U.S. Nuclear Regulatory Commission fire protection inspection program&amp;#039;&amp;#039; (NUREG-1805). U.S. Nuclear Regulatory Commission.&lt;br /&gt;
* Schifiliti, R. P., Meacham, B. J., &amp;amp; Custer, R. L. P. (2002). Design of detection systems. In P. J. DiNenno (Ed.), &amp;#039;&amp;#039;SFPE handbook of fire protection engineering&amp;#039;&amp;#039; (3rd ed., pp. 4-1–4-43). National Fire Protection Association.&lt;br /&gt;
&lt;br /&gt;
[[Category:Passive Fire Protection]]&lt;/div&gt;</summary>
		<author><name>Linda</name></author>
	</entry>
</feed>