<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://fire-safety.academy/w/index.php?action=history&amp;feed=atom&amp;title=Fuel_cell_vehicle</id>
	<title>Fuel cell vehicle - Revision history</title>
	<link rel="self" type="application/atom+xml" href="https://fire-safety.academy/w/index.php?action=history&amp;feed=atom&amp;title=Fuel_cell_vehicle"/>
	<link rel="alternate" type="text/html" href="https://fire-safety.academy/w/index.php?title=Fuel_cell_vehicle&amp;action=history"/>
	<updated>2026-11-21T23:29:54Z</updated>
	<subtitle>Revision history for this page on the wiki</subtitle>
	<generator>MediaWiki 1.43.11</generator>
	<entry>
		<id>https://fire-safety.academy/w/index.php?title=Fuel_cell_vehicle&amp;diff=9453&amp;oldid=prev</id>
		<title>Peter: Wiki review: corrected 1 error: content (Claude Opus 5.5)</title>
		<link rel="alternate" type="text/html" href="https://fire-safety.academy/w/index.php?title=Fuel_cell_vehicle&amp;diff=9453&amp;oldid=prev"/>
		<updated>2026-11-15T23:49:23Z</updated>

		<summary type="html">&lt;p&gt;Wiki review: corrected 1 error: content (Claude Opus 5.5)&lt;/p&gt;
&lt;table style=&quot;background-color: #fff; color: #202122;&quot; data-mw=&quot;interface&quot;&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;tr class=&quot;diff-title&quot; lang=&quot;en&quot;&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;← Older revision&lt;/td&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;Revision as of 00:49, 16 November 2026&lt;/td&gt;
				&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l26&quot;&gt;Line 26:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 26:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Hydrogen has an extremely wide flammable range, from about 4 % to 75 % by volume in air, and the highest burning velocity of any gas.&amp;lt;ref name=&amp;quot;Lemoff-6-181&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;Rivkin-21-55&amp;quot;&amp;gt;Rivkin (2008b), p. 21-55.&amp;lt;/ref&amp;gt; Its ignition temperature is reasonably high, but its ignition energy is very low, and with a density of only 0.07 relative to air it disperses rapidly.&amp;lt;ref name=&amp;quot;Lemoff-6-181&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;Rivkin-21-55&amp;quot; /&amp;gt; Because it contains no carbon, it burns with a nonluminous flame that is often invisible in daylight and gives off little thermal radiation, so people can walk into it unaware.&amp;lt;ref name=&amp;quot;Lemoff-6-181&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;Lemoff-6-182&amp;quot;&amp;gt;Lemoff (2008), p. 6-182.&amp;lt;/ref&amp;gt; For [[Hydrogen safety|hydrogen safety]] these properties work in both directions. The wide flammable range and high burning rate accentuate the hazard, while the low ignition energy, low heat of combustion per unit volume and low-radiation flame counteract it in many cases.&amp;lt;ref name=&amp;quot;Lemoff-6-181&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Hydrogen has an extremely wide flammable range, from about 4 % to 75 % by volume in air, and the highest burning velocity of any gas.&amp;lt;ref name=&amp;quot;Lemoff-6-181&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;Rivkin-21-55&amp;quot;&amp;gt;Rivkin (2008b), p. 21-55.&amp;lt;/ref&amp;gt; Its ignition temperature is reasonably high, but its ignition energy is very low, and with a density of only 0.07 relative to air it disperses rapidly.&amp;lt;ref name=&amp;quot;Lemoff-6-181&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;Rivkin-21-55&amp;quot; /&amp;gt; Because it contains no carbon, it burns with a nonluminous flame that is often invisible in daylight and gives off little thermal radiation, so people can walk into it unaware.&amp;lt;ref name=&amp;quot;Lemoff-6-181&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;Lemoff-6-182&amp;quot;&amp;gt;Lemoff (2008), p. 6-182.&amp;lt;/ref&amp;gt; For [[Hydrogen safety|hydrogen safety]] these properties work in both directions. The wide flammable range and high burning rate accentuate the hazard, while the low ignition energy, low heat of combustion per unit volume and low-radiation flame counteract it in many cases.&amp;lt;ref name=&amp;quot;Lemoff-6-181&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;How a release behaves depends on its pressure. When gaseous hydrogen escapes at high pressure, small heat sources such as friction or static electricity can ignite it promptly, so it often behaves as if it were self-igniting. Such releases usually lead to fires rather than explosions.&amp;lt;ref name=&quot;Lemoff-6-181&quot; /&amp;gt; At low pressure self-ignition is unlikely, but an accumulated cloud can explode with a very rapid pressure rise that is extremely difficult to vent.&amp;lt;ref name=&quot;Lemoff-6-181&quot; /&amp;gt; Escaping hydrogen gas seldom &lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;leaves &lt;/del&gt;a &lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;situation without &lt;/del&gt;fire, because it either ignites promptly or rises rapidly.&amp;lt;ref name=&quot;Lemoff-6-182&quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;How a release behaves depends on its pressure. When gaseous hydrogen escapes at high pressure, small heat sources such as friction or static electricity can ignite it promptly, so it often behaves as if it were self-igniting. Such releases usually lead to fires rather than explosions.&amp;lt;ref name=&quot;Lemoff-6-181&quot; /&amp;gt; At low pressure self-ignition is unlikely, but an accumulated cloud can explode with a very rapid pressure rise that is extremely difficult to vent.&amp;lt;ref name=&quot;Lemoff-6-181&quot; /&amp;gt; Escaping hydrogen gas seldom &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;presents &lt;/ins&gt;a &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;&quot;no &lt;/ins&gt;fire&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;&quot; emergency&lt;/ins&gt;, because it either ignites promptly or rises rapidly &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;into the atmosphere&lt;/ins&gt;.&amp;lt;ref name=&quot;Lemoff-6-182&quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Whether a discharge from a vehicle can burn depends on how it mixes with air. A mixture of hydrogen, oxygen and nitrogen is potentially flammable when it contains more than 4 % hydrogen and more than 5 % oxygen by volume.&amp;lt;ref name=&amp;quot;SC-21-86&amp;quot; /&amp;gt; A discharge already diluted to 5 % hydrogen with inert gas never becomes flammable, because its hydrogen falls below 4 % before the oxygen reaches 5 %. Pure hydrogen, in contrast, passes through a flammable mixture as it disperses.&amp;lt;ref name=&amp;quot;SC-21-86&amp;quot; /&amp;gt; The 4 % limit comes from tests on uniform, quiescent mixtures. Tests on discharges have shown that flow and mixing can suppress ignition, and that more than 8 % hydrogen is typically needed to ignite them.&amp;lt;ref name=&amp;quot;SC-21-86&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Whether a discharge from a vehicle can burn depends on how it mixes with air. A mixture of hydrogen, oxygen and nitrogen is potentially flammable when it contains more than 4 % hydrogen and more than 5 % oxygen by volume.&amp;lt;ref name=&amp;quot;SC-21-86&amp;quot; /&amp;gt; A discharge already diluted to 5 % hydrogen with inert gas never becomes flammable, because its hydrogen falls below 4 % before the oxygen reaches 5 %. Pure hydrogen, in contrast, passes through a flammable mixture as it disperses.&amp;lt;ref name=&amp;quot;SC-21-86&amp;quot; /&amp;gt; The 4 % limit comes from tests on uniform, quiescent mixtures. Tests on discharges have shown that flow and mixing can suppress ignition, and that more than 8 % hydrogen is typically needed to ignite them.&amp;lt;ref name=&amp;quot;SC-21-86&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;

&lt;!-- diff cache key firesb_pjbsiy42-wiki_:diff:1.41:old-6651:rev-9453:php=table --&gt;
&lt;/table&gt;</summary>
		<author><name>Peter</name></author>
	</entry>
	<entry>
		<id>https://fire-safety.academy/w/index.php?title=Fuel_cell_vehicle&amp;diff=6651&amp;oldid=prev</id>
		<title>Mark: Remove source references from image captions</title>
		<link rel="alternate" type="text/html" href="https://fire-safety.academy/w/index.php?title=Fuel_cell_vehicle&amp;diff=6651&amp;oldid=prev"/>
		<updated>2026-11-13T07:29:52Z</updated>

		<summary type="html">&lt;p&gt;Remove source references from image captions&lt;/p&gt;
&lt;table style=&quot;background-color: #fff; color: #202122;&quot; data-mw=&quot;interface&quot;&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;tr class=&quot;diff-title&quot; lang=&quot;en&quot;&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;← Older revision&lt;/td&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;Revision as of 08:29, 13 November 2026&lt;/td&gt;
				&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l5&quot;&gt;Line 5:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 5:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Principle and main components ==&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Principle and main components ==&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;A [[Fuel cell]] has two electrodes, an anode and a cathode, separated by an electrolyte. Unlike a battery, it stores its fuel and oxidant outside the cell, so it keeps operating as long as both are replenished.&amp;lt;ref name=&amp;quot;Biggins-8-108&amp;quot;&amp;gt;Biggins (2008), p. 8-108.&amp;lt;/ref&amp;gt; Almost all prototype fuel cell cars and buses described in the 2008 handbook used proton exchange membrane (PEM) fuel cells. Each cell is a thin wafer: a catalyst-coated membrane enclosed in electrically conducting graphite or metal plates.&amp;lt;ref name=&amp;quot;SC-21-81&amp;quot;&amp;gt;Scheffler and Collins (2008), p. 21-81.&amp;lt;/ref&amp;gt; At the anode, hydrogen atoms release their electrons and become protons, which pass through the membrane to the cathode. There they combine with oxygen from the air and with the electrons, which have flowed through the external circuit, to form water.&amp;lt;ref name=&amp;quot;SC-21-81&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;A [[Fuel cell]] has two electrodes, an anode and a cathode, separated by an electrolyte. Unlike a battery, it stores its fuel and oxidant outside the cell, so it keeps operating as long as both are replenished.&amp;lt;ref name=&amp;quot;Biggins-8-108&amp;quot;&amp;gt;Biggins (2008), p. 8-108.&amp;lt;/ref&amp;gt; Almost all prototype fuel cell cars and buses described in the 2008 handbook used proton exchange membrane (PEM) fuel cells. Each cell is a thin wafer: a catalyst-coated membrane enclosed in electrically conducting graphite or metal plates.&amp;lt;ref name=&amp;quot;SC-21-81&amp;quot;&amp;gt;Scheffler and Collins (2008), p. 21-81.&amp;lt;/ref&amp;gt; At the anode, hydrogen atoms release their electrons and become protons, which pass through the membrane to the cathode. There they combine with oxygen from the air and with the electrons, which have flowed through the external circuit, to form water.&amp;lt;ref name=&amp;quot;SC-21-81&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[[File:fse-fuel-cell-vehicle-v1.svg|thumb|upright=1.5|alt=Cross-section of a PEM fuel cell with hydrogen at the anode, protons crossing the membrane, oxygen at the cathode and water leaving|Operating principle of a proton exchange membrane (PEM) fuel cell&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;. Based on Scheffler and Collins (2008), p. 21-81 (Figure 21.5.10, redrawn)&lt;/del&gt;.]]&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[[File:fse-fuel-cell-vehicle-v1.svg|thumb|upright=1.5|alt=Cross-section of a PEM fuel cell with hydrogen at the anode, protons crossing the membrane, oxygen at the cathode and water leaving|Operating principle of a proton exchange membrane (PEM) fuel cell.]]&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Cells are assembled in stacks to give enough power and voltage for the drive system; stacks of 50 kW to 150 kW powered prototype cars, minivans and transit buses.&amp;lt;ref name=&amp;quot;SC-21-81&amp;quot; /&amp;gt; The rest of the fuel cell system, the balance of plant, delivers hydrogen to the stack, supplies fresh air to the cathodes and manages stack temperature and water.&amp;lt;ref name=&amp;quot;SC-21-81&amp;quot; /&amp;gt; A power control turns the driver&amp;#039;s throttle input into electric power for the drive motors.&amp;lt;ref name=&amp;quot;SC-21-78&amp;quot; /&amp;gt; Many FCVs are hybrids that recover braking energy and store it in batteries or ultracapacitors. Some carry a separate small fuel cell, an auxiliary power unit of typically 3 kW to 10 kW, for systems such as radios and air conditioning.&amp;lt;ref name=&amp;quot;SC-21-78&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Cells are assembled in stacks to give enough power and voltage for the drive system; stacks of 50 kW to 150 kW powered prototype cars, minivans and transit buses.&amp;lt;ref name=&amp;quot;SC-21-81&amp;quot; /&amp;gt; The rest of the fuel cell system, the balance of plant, delivers hydrogen to the stack, supplies fresh air to the cathodes and manages stack temperature and water.&amp;lt;ref name=&amp;quot;SC-21-81&amp;quot; /&amp;gt; A power control turns the driver&amp;#039;s throttle input into electric power for the drive motors.&amp;lt;ref name=&amp;quot;SC-21-78&amp;quot; /&amp;gt; Many FCVs are hybrids that recover braking energy and store it in batteries or ultracapacitors. Some carry a separate small fuel cell, an auxiliary power unit of typically 3 kW to 10 kW, for systems such as radios and air conditioning.&amp;lt;ref name=&amp;quot;SC-21-78&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l17&quot;&gt;Line 17:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 17:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The storage system has four main functions. A filling receptacle, for example to SAE J2600, typically contains a check valve to limit backflow when the nozzle is disconnected, and a second check valve usually provides redundancy.&amp;lt;ref name=&amp;quot;SC-21-84&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;SC-21-85&amp;quot; /&amp;gt; One or more containers hold the gas, and shutoff valves and pressure regulators control its delivery to the fuel cells, as on compressed natural gas vehicles. One or more pressure relief devices are intended to reduce the risk of tank rupture if the system is exposed to fire.&amp;lt;ref name=&amp;quot;SC-21-85&amp;quot; /&amp;gt; The containers draw on experience with compressed natural gas and are designed to contain hydrogen without bursting.&amp;lt;ref name=&amp;quot;SC-21-85&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The storage system has four main functions. A filling receptacle, for example to SAE J2600, typically contains a check valve to limit backflow when the nozzle is disconnected, and a second check valve usually provides redundancy.&amp;lt;ref name=&amp;quot;SC-21-84&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;SC-21-85&amp;quot; /&amp;gt; One or more containers hold the gas, and shutoff valves and pressure regulators control its delivery to the fuel cells, as on compressed natural gas vehicles. One or more pressure relief devices are intended to reduce the risk of tank rupture if the system is exposed to fire.&amp;lt;ref name=&amp;quot;SC-21-85&amp;quot; /&amp;gt; The containers draw on experience with compressed natural gas and are designed to contain hydrogen without bursting.&amp;lt;ref name=&amp;quot;SC-21-85&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[[File:fse-fuel-cell-vehicle-v2.svg|thumb|upright=1.5|alt=Schematic of a vehicle compressed hydrogen system with receptacle, check valves, container, shutoff valve, relief device and regulator|Compressed hydrogen storage system of a fuel cell vehicle&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;. Based on Scheffler and Collins (2008), pp. 21-84–21-85 (Figure 21.5.19, redrawn)&lt;/del&gt;.]]&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[[File:fse-fuel-cell-vehicle-v2.svg|thumb|upright=1.5|alt=Schematic of a vehicle compressed hydrogen system with receptacle, check valves, container, shutoff valve, relief device and regulator|Compressed hydrogen storage system of a fuel cell vehicle.]]&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Compressed hydrogen cylinders are protected against overpressure by frangible (bursting) discs, alone or combined with fusible plugs. Because they contain no liquid, they are not subject to a [[BLEVE|boiling liquid expanding vapour explosion]], although they can still fail.&amp;lt;ref name=&amp;quot;Lemoff-6-181&amp;quot; /&amp;gt; For identification, SAE recommended a blue diamond label like the one used on natural gas vehicles, marked with compressed hydrogen or the other storage method used.&amp;lt;ref name=&amp;quot;SC-21-85&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Compressed hydrogen cylinders are protected against overpressure by frangible (bursting) discs, alone or combined with fusible plugs. Because they contain no liquid, they are not subject to a [[BLEVE|boiling liquid expanding vapour explosion]], although they can still fail.&amp;lt;ref name=&amp;quot;Lemoff-6-181&amp;quot; /&amp;gt; For identification, SAE recommended a blue diamond label like the one used on natural gas vehicles, marked with compressed hydrogen or the other storage method used.&amp;lt;ref name=&amp;quot;SC-21-85&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l29&quot;&gt;Line 29:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 29:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Whether a discharge from a vehicle can burn depends on how it mixes with air. A mixture of hydrogen, oxygen and nitrogen is potentially flammable when it contains more than 4 % hydrogen and more than 5 % oxygen by volume.&amp;lt;ref name=&amp;quot;SC-21-86&amp;quot; /&amp;gt; A discharge already diluted to 5 % hydrogen with inert gas never becomes flammable, because its hydrogen falls below 4 % before the oxygen reaches 5 %. Pure hydrogen, in contrast, passes through a flammable mixture as it disperses.&amp;lt;ref name=&amp;quot;SC-21-86&amp;quot; /&amp;gt; The 4 % limit comes from tests on uniform, quiescent mixtures. Tests on discharges have shown that flow and mixing can suppress ignition, and that more than 8 % hydrogen is typically needed to ignite them.&amp;lt;ref name=&amp;quot;SC-21-86&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Whether a discharge from a vehicle can burn depends on how it mixes with air. A mixture of hydrogen, oxygen and nitrogen is potentially flammable when it contains more than 4 % hydrogen and more than 5 % oxygen by volume.&amp;lt;ref name=&amp;quot;SC-21-86&amp;quot; /&amp;gt; A discharge already diluted to 5 % hydrogen with inert gas never becomes flammable, because its hydrogen falls below 4 % before the oxygen reaches 5 %. Pure hydrogen, in contrast, passes through a flammable mixture as it disperses.&amp;lt;ref name=&amp;quot;SC-21-86&amp;quot; /&amp;gt; The 4 % limit comes from tests on uniform, quiescent mixtures. Tests on discharges have shown that flow and mixing can suppress ignition, and that more than 8 % hydrogen is typically needed to ignite them.&amp;lt;ref name=&amp;quot;SC-21-86&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[[File:fse-fuel-cell-vehicle-v3.svg|thumb|upright=1.5|alt=Chart of oxygen versus hydrogen percentage with a potentially flammable region and two mixing lines from the discharge to air|Potential flammability of hydrogen discharges as they mix with air: a discharge diluted to 5 % hydrogen stays outside the potentially flammable region, a pure discharge crosses it&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;. Based on Scheffler and Collins (2008), p. 21-86 (Figure 21.5.20, redrawn)&lt;/del&gt;.]]&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[[File:fse-fuel-cell-vehicle-v3.svg|thumb|upright=1.5|alt=Chart of oxygen versus hydrogen percentage with a potentially flammable region and two mixing lines from the discharge to air|Potential flammability of hydrogen discharges as they mix with air: a discharge diluted to 5 % hydrogen stays outside the potentially flammable region, a pure discharge crosses it.]]&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;An ignited release from a small opening forms a [[Jet fire]]. The SFPE Handbook gives an example for hydrogen flowing from a 5 mm nozzle out of a reservoir at 300 kPa.&amp;lt;ref name=&amp;quot;Heskestad-2-5&amp;quot;&amp;gt;Heskestad (2002), p. 2-5.&amp;lt;/ref&amp;gt; The flow is choked at 3.65 g/s, the heat release rate is 436 kW, and the flame is about 239 nozzle diameters long, or about 1.2 m.&amp;lt;ref name=&amp;quot;Heskestad-2-5&amp;quot; /&amp;gt; In this momentum-dominated regime the flame length is proportional to the opening diameter for a given gas and discharge density.&amp;lt;ref name=&amp;quot;Heskestad-2-4&amp;quot;&amp;gt;Heskestad (2002), pp. 2-4–2-5.&amp;lt;/ref&amp;gt; Vehicle storage pressures are more than a hundred times higher than in this example, so it shows the scaling, not the flame length from a vehicle leak.&amp;lt;ref name=&amp;quot;SC-21-84&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;An ignited release from a small opening forms a [[Jet fire]]. The SFPE Handbook gives an example for hydrogen flowing from a 5 mm nozzle out of a reservoir at 300 kPa.&amp;lt;ref name=&amp;quot;Heskestad-2-5&amp;quot;&amp;gt;Heskestad (2002), p. 2-5.&amp;lt;/ref&amp;gt; The flow is choked at 3.65 g/s, the heat release rate is 436 kW, and the flame is about 239 nozzle diameters long, or about 1.2 m.&amp;lt;ref name=&amp;quot;Heskestad-2-5&amp;quot; /&amp;gt; In this momentum-dominated regime the flame length is proportional to the opening diameter for a given gas and discharge density.&amp;lt;ref name=&amp;quot;Heskestad-2-4&amp;quot;&amp;gt;Heskestad (2002), pp. 2-4–2-5.&amp;lt;/ref&amp;gt; Vehicle storage pressures are more than a hundred times higher than in this example, so it shows the scaling, not the flame length from a vehicle leak.&amp;lt;ref name=&amp;quot;SC-21-84&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l77&quot;&gt;Line 77:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 77:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Fuelling borrows its static protection from gasoline. The handbook describes a conductive path from the fuelling neck to the tyres and from the tyre contact surface to the station nozzle.&amp;lt;ref name=&amp;quot;SC-21-87&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;SC-21-88&amp;quot;&amp;gt;Scheffler and Collins (2008), p. 21-88.&amp;lt;/ref&amp;gt; This [[Bonding and grounding|bonding and grounding]] path reduces the risk of ignition by static sparks, and the countermeasure was adapted to hydrogen fuelling.&amp;lt;ref name=&amp;quot;SC-21-88&amp;quot; /&amp;gt; The handbook also calls for station leak detection, emergency shutoff on a fault, and breakaway protection if the vehicle moves off with the nozzle connected.&amp;lt;ref name=&amp;quot;SC-21-88&amp;quot; /&amp;gt; Station relief valves are intended to protect vehicle storage against overpressure. The stated setting is 1.38 times nominal working pressure: 48.3 MPa for a 35 MPa system and 96.6 MPa for a 70 MPa system.&amp;lt;ref name=&amp;quot;SC-21-88&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Fuelling borrows its static protection from gasoline. The handbook describes a conductive path from the fuelling neck to the tyres and from the tyre contact surface to the station nozzle.&amp;lt;ref name=&amp;quot;SC-21-87&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;SC-21-88&amp;quot;&amp;gt;Scheffler and Collins (2008), p. 21-88.&amp;lt;/ref&amp;gt; This [[Bonding and grounding|bonding and grounding]] path reduces the risk of ignition by static sparks, and the countermeasure was adapted to hydrogen fuelling.&amp;lt;ref name=&amp;quot;SC-21-88&amp;quot; /&amp;gt; The handbook also calls for station leak detection, emergency shutoff on a fault, and breakaway protection if the vehicle moves off with the nozzle connected.&amp;lt;ref name=&amp;quot;SC-21-88&amp;quot; /&amp;gt; Station relief valves are intended to protect vehicle storage against overpressure. The stated setting is 1.38 times nominal working pressure: 48.3 MPa for a 35 MPa system and 96.6 MPa for a 70 MPa system.&amp;lt;ref name=&amp;quot;SC-21-88&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[[File:fse-fuel-cell-vehicle-v4.svg|thumb|upright=1.5|alt=Horizontal bar chart of pressures for natural gas systems, hydrogen vehicle storage and hydrogen station relief settings|Pressures of natural gas and hydrogen fuelling systems, with station relief valve settings at 1.38 times the nominal working pressure&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;. Based on Scheffler and Collins (2008), pp. 21-84 and 21-88, and Rivkin (2008b), pp. 21-69 and 21-74&lt;/del&gt;.]]&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[[File:fse-fuel-cell-vehicle-v4.svg|thumb|upright=1.5|alt=Horizontal bar chart of pressures for natural gas systems, hydrogen vehicle storage and hydrogen station relief settings|Pressures of natural gas and hydrogen fuelling systems, with station relief valve settings at 1.38 times the nominal working pressure.]]&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Repair garages built to NFPA 30A, &amp;#039;&amp;#039;Code for Motor Fuel Dispensing Facilities and Repair Garages&amp;#039;&amp;#039;, were considered adequate for FCVs as long as nobody works on the hydrogen storage system.&amp;lt;ref name=&amp;quot;SC-21-88&amp;quot; /&amp;gt; Areas for such work need more. A vent system will probably be required to depressurise and purge the vehicle storage system before major repairs.&amp;lt;ref name=&amp;quot;SC-21-88&amp;quot; /&amp;gt; Ventilation, gas and fire detection, electrical classification, links between the ventilation system and other areas, and the fire rating of walls and doors should also be considered.&amp;lt;ref name=&amp;quot;SC-21-88&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Repair garages built to NFPA 30A, &amp;#039;&amp;#039;Code for Motor Fuel Dispensing Facilities and Repair Garages&amp;#039;&amp;#039;, were considered adequate for FCVs as long as nobody works on the hydrogen storage system.&amp;lt;ref name=&amp;quot;SC-21-88&amp;quot; /&amp;gt; Areas for such work need more. A vent system will probably be required to depressurise and purge the vehicle storage system before major repairs.&amp;lt;ref name=&amp;quot;SC-21-88&amp;quot; /&amp;gt; Ventilation, gas and fire detection, electrical classification, links between the ventilation system and other areas, and the fire rating of walls and doors should also be considered.&amp;lt;ref name=&amp;quot;SC-21-88&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;

&lt;!-- diff cache key firesb_pjbsiy42-wiki_:diff:1.41:old-5927:rev-6651:php=table --&gt;
&lt;/table&gt;</summary>
		<author><name>Mark</name></author>
	</entry>
	<entry>
		<id>https://fire-safety.academy/w/index.php?title=Fuel_cell_vehicle&amp;diff=5927&amp;oldid=prev</id>
		<title>Peter: Add SVG figures fse-fuel-cell-vehicle-v1.svg, fse-fuel-cell-vehicle-v2.svg, fse-fuel-cell-vehicle-v3.svg, fse-fuel-cell-vehicle-v4.svg (list-3 visual plan)</title>
		<link rel="alternate" type="text/html" href="https://fire-safety.academy/w/index.php?title=Fuel_cell_vehicle&amp;diff=5927&amp;oldid=prev"/>
		<updated>2026-11-12T12:22:38Z</updated>

		<summary type="html">&lt;p&gt;Add SVG figures fse-fuel-cell-vehicle-v1.svg, fse-fuel-cell-vehicle-v2.svg, fse-fuel-cell-vehicle-v3.svg, fse-fuel-cell-vehicle-v4.svg (list-3 visual plan)&lt;/p&gt;
&lt;table style=&quot;background-color: #fff; color: #202122;&quot; data-mw=&quot;interface&quot;&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;tr class=&quot;diff-title&quot; lang=&quot;en&quot;&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;← Older revision&lt;/td&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;Revision as of 13:22, 12 November 2026&lt;/td&gt;
				&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l5&quot;&gt;Line 5:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 5:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Principle and main components ==&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Principle and main components ==&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;A [[Fuel cell]] has two electrodes, an anode and a cathode, separated by an electrolyte. Unlike a battery, it stores its fuel and oxidant outside the cell, so it keeps operating as long as both are replenished.&amp;lt;ref name=&amp;quot;Biggins-8-108&amp;quot;&amp;gt;Biggins (2008), p. 8-108.&amp;lt;/ref&amp;gt; Almost all prototype fuel cell cars and buses described in the 2008 handbook used proton exchange membrane (PEM) fuel cells. Each cell is a thin wafer: a catalyst-coated membrane enclosed in electrically conducting graphite or metal plates.&amp;lt;ref name=&amp;quot;SC-21-81&amp;quot;&amp;gt;Scheffler and Collins (2008), p. 21-81.&amp;lt;/ref&amp;gt; At the anode, hydrogen atoms release their electrons and become protons, which pass through the membrane to the cathode. There they combine with oxygen from the air and with the electrons, which have flowed through the external circuit, to form water.&amp;lt;ref name=&amp;quot;SC-21-81&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;A [[Fuel cell]] has two electrodes, an anode and a cathode, separated by an electrolyte. Unlike a battery, it stores its fuel and oxidant outside the cell, so it keeps operating as long as both are replenished.&amp;lt;ref name=&amp;quot;Biggins-8-108&amp;quot;&amp;gt;Biggins (2008), p. 8-108.&amp;lt;/ref&amp;gt; Almost all prototype fuel cell cars and buses described in the 2008 handbook used proton exchange membrane (PEM) fuel cells. Each cell is a thin wafer: a catalyst-coated membrane enclosed in electrically conducting graphite or metal plates.&amp;lt;ref name=&amp;quot;SC-21-81&amp;quot;&amp;gt;Scheffler and Collins (2008), p. 21-81.&amp;lt;/ref&amp;gt; At the anode, hydrogen atoms release their electrons and become protons, which pass through the membrane to the cathode. There they combine with oxygen from the air and with the electrons, which have flowed through the external circuit, to form water.&amp;lt;ref name=&amp;quot;SC-21-81&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-deleted&quot;&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;[[File:fse-fuel-cell-vehicle-v1.svg|thumb|upright=1.5|alt=Cross-section of a PEM fuel cell with hydrogen at the anode, protons crossing the membrane, oxygen at the cathode and water leaving|Operating principle of a proton exchange membrane (PEM) fuel cell. Based on Scheffler and Collins (2008), p. 21-81 (Figure 21.5.10, redrawn).]]&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Cells are assembled in stacks to give enough power and voltage for the drive system; stacks of 50 kW to 150 kW powered prototype cars, minivans and transit buses.&amp;lt;ref name=&amp;quot;SC-21-81&amp;quot; /&amp;gt; The rest of the fuel cell system, the balance of plant, delivers hydrogen to the stack, supplies fresh air to the cathodes and manages stack temperature and water.&amp;lt;ref name=&amp;quot;SC-21-81&amp;quot; /&amp;gt; A power control turns the driver&amp;#039;s throttle input into electric power for the drive motors.&amp;lt;ref name=&amp;quot;SC-21-78&amp;quot; /&amp;gt; Many FCVs are hybrids that recover braking energy and store it in batteries or ultracapacitors. Some carry a separate small fuel cell, an auxiliary power unit of typically 3 kW to 10 kW, for systems such as radios and air conditioning.&amp;lt;ref name=&amp;quot;SC-21-78&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Cells are assembled in stacks to give enough power and voltage for the drive system; stacks of 50 kW to 150 kW powered prototype cars, minivans and transit buses.&amp;lt;ref name=&amp;quot;SC-21-81&amp;quot; /&amp;gt; The rest of the fuel cell system, the balance of plant, delivers hydrogen to the stack, supplies fresh air to the cathodes and manages stack temperature and water.&amp;lt;ref name=&amp;quot;SC-21-81&amp;quot; /&amp;gt; A power control turns the driver&amp;#039;s throttle input into electric power for the drive motors.&amp;lt;ref name=&amp;quot;SC-21-78&amp;quot; /&amp;gt; Many FCVs are hybrids that recover braking energy and store it in batteries or ultracapacitors. Some carry a separate small fuel cell, an auxiliary power unit of typically 3 kW to 10 kW, for systems such as radios and air conditioning.&amp;lt;ref name=&amp;quot;SC-21-78&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l16&quot;&gt;Line 16:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 17:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The storage system has four main functions. A filling receptacle, for example to SAE J2600, typically contains a check valve to limit backflow when the nozzle is disconnected, and a second check valve usually provides redundancy.&amp;lt;ref name=&amp;quot;SC-21-84&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;SC-21-85&amp;quot; /&amp;gt; One or more containers hold the gas, and shutoff valves and pressure regulators control its delivery to the fuel cells, as on compressed natural gas vehicles. One or more pressure relief devices are intended to reduce the risk of tank rupture if the system is exposed to fire.&amp;lt;ref name=&amp;quot;SC-21-85&amp;quot; /&amp;gt; The containers draw on experience with compressed natural gas and are designed to contain hydrogen without bursting.&amp;lt;ref name=&amp;quot;SC-21-85&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The storage system has four main functions. A filling receptacle, for example to SAE J2600, typically contains a check valve to limit backflow when the nozzle is disconnected, and a second check valve usually provides redundancy.&amp;lt;ref name=&amp;quot;SC-21-84&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;SC-21-85&amp;quot; /&amp;gt; One or more containers hold the gas, and shutoff valves and pressure regulators control its delivery to the fuel cells, as on compressed natural gas vehicles. One or more pressure relief devices are intended to reduce the risk of tank rupture if the system is exposed to fire.&amp;lt;ref name=&amp;quot;SC-21-85&amp;quot; /&amp;gt; The containers draw on experience with compressed natural gas and are designed to contain hydrogen without bursting.&amp;lt;ref name=&amp;quot;SC-21-85&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-deleted&quot;&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;[[File:fse-fuel-cell-vehicle-v2.svg|thumb|upright=1.5|alt=Schematic of a vehicle compressed hydrogen system with receptacle, check valves, container, shutoff valve, relief device and regulator|Compressed hydrogen storage system of a fuel cell vehicle. Based on Scheffler and Collins (2008), pp. 21-84–21-85 (Figure 21.5.19, redrawn).]]&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Compressed hydrogen cylinders are protected against overpressure by frangible (bursting) discs, alone or combined with fusible plugs. Because they contain no liquid, they are not subject to a [[BLEVE|boiling liquid expanding vapour explosion]], although they can still fail.&amp;lt;ref name=&amp;quot;Lemoff-6-181&amp;quot; /&amp;gt; For identification, SAE recommended a blue diamond label like the one used on natural gas vehicles, marked with compressed hydrogen or the other storage method used.&amp;lt;ref name=&amp;quot;SC-21-85&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Compressed hydrogen cylinders are protected against overpressure by frangible (bursting) discs, alone or combined with fusible plugs. Because they contain no liquid, they are not subject to a [[BLEVE|boiling liquid expanding vapour explosion]], although they can still fail.&amp;lt;ref name=&amp;quot;Lemoff-6-181&amp;quot; /&amp;gt; For identification, SAE recommended a blue diamond label like the one used on natural gas vehicles, marked with compressed hydrogen or the other storage method used.&amp;lt;ref name=&amp;quot;SC-21-85&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l27&quot;&gt;Line 27:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 29:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Whether a discharge from a vehicle can burn depends on how it mixes with air. A mixture of hydrogen, oxygen and nitrogen is potentially flammable when it contains more than 4 % hydrogen and more than 5 % oxygen by volume.&amp;lt;ref name=&amp;quot;SC-21-86&amp;quot; /&amp;gt; A discharge already diluted to 5 % hydrogen with inert gas never becomes flammable, because its hydrogen falls below 4 % before the oxygen reaches 5 %. Pure hydrogen, in contrast, passes through a flammable mixture as it disperses.&amp;lt;ref name=&amp;quot;SC-21-86&amp;quot; /&amp;gt; The 4 % limit comes from tests on uniform, quiescent mixtures. Tests on discharges have shown that flow and mixing can suppress ignition, and that more than 8 % hydrogen is typically needed to ignite them.&amp;lt;ref name=&amp;quot;SC-21-86&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Whether a discharge from a vehicle can burn depends on how it mixes with air. A mixture of hydrogen, oxygen and nitrogen is potentially flammable when it contains more than 4 % hydrogen and more than 5 % oxygen by volume.&amp;lt;ref name=&amp;quot;SC-21-86&amp;quot; /&amp;gt; A discharge already diluted to 5 % hydrogen with inert gas never becomes flammable, because its hydrogen falls below 4 % before the oxygen reaches 5 %. Pure hydrogen, in contrast, passes through a flammable mixture as it disperses.&amp;lt;ref name=&amp;quot;SC-21-86&amp;quot; /&amp;gt; The 4 % limit comes from tests on uniform, quiescent mixtures. Tests on discharges have shown that flow and mixing can suppress ignition, and that more than 8 % hydrogen is typically needed to ignite them.&amp;lt;ref name=&amp;quot;SC-21-86&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-deleted&quot;&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;[[File:fse-fuel-cell-vehicle-v3.svg|thumb|upright=1.5|alt=Chart of oxygen versus hydrogen percentage with a potentially flammable region and two mixing lines from the discharge to air|Potential flammability of hydrogen discharges as they mix with air: a discharge diluted to 5 % hydrogen stays outside the potentially flammable region, a pure discharge crosses it. Based on Scheffler and Collins (2008), p. 21-86 (Figure 21.5.20, redrawn).]]&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;An ignited release from a small opening forms a [[Jet fire]]. The SFPE Handbook gives an example for hydrogen flowing from a 5 mm nozzle out of a reservoir at 300 kPa.&amp;lt;ref name=&amp;quot;Heskestad-2-5&amp;quot;&amp;gt;Heskestad (2002), p. 2-5.&amp;lt;/ref&amp;gt; The flow is choked at 3.65 g/s, the heat release rate is 436 kW, and the flame is about 239 nozzle diameters long, or about 1.2 m.&amp;lt;ref name=&amp;quot;Heskestad-2-5&amp;quot; /&amp;gt; In this momentum-dominated regime the flame length is proportional to the opening diameter for a given gas and discharge density.&amp;lt;ref name=&amp;quot;Heskestad-2-4&amp;quot;&amp;gt;Heskestad (2002), pp. 2-4–2-5.&amp;lt;/ref&amp;gt; Vehicle storage pressures are more than a hundred times higher than in this example, so it shows the scaling, not the flame length from a vehicle leak.&amp;lt;ref name=&amp;quot;SC-21-84&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;An ignited release from a small opening forms a [[Jet fire]]. The SFPE Handbook gives an example for hydrogen flowing from a 5 mm nozzle out of a reservoir at 300 kPa.&amp;lt;ref name=&amp;quot;Heskestad-2-5&amp;quot;&amp;gt;Heskestad (2002), p. 2-5.&amp;lt;/ref&amp;gt; The flow is choked at 3.65 g/s, the heat release rate is 436 kW, and the flame is about 239 nozzle diameters long, or about 1.2 m.&amp;lt;ref name=&amp;quot;Heskestad-2-5&amp;quot; /&amp;gt; In this momentum-dominated regime the flame length is proportional to the opening diameter for a given gas and discharge density.&amp;lt;ref name=&amp;quot;Heskestad-2-4&amp;quot;&amp;gt;Heskestad (2002), pp. 2-4–2-5.&amp;lt;/ref&amp;gt; Vehicle storage pressures are more than a hundred times higher than in this example, so it shows the scaling, not the flame length from a vehicle leak.&amp;lt;ref name=&amp;quot;SC-21-84&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l74&quot;&gt;Line 74:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 77:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Fuelling borrows its static protection from gasoline. The handbook describes a conductive path from the fuelling neck to the tyres and from the tyre contact surface to the station nozzle.&amp;lt;ref name=&amp;quot;SC-21-87&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;SC-21-88&amp;quot;&amp;gt;Scheffler and Collins (2008), p. 21-88.&amp;lt;/ref&amp;gt; This [[Bonding and grounding|bonding and grounding]] path reduces the risk of ignition by static sparks, and the countermeasure was adapted to hydrogen fuelling.&amp;lt;ref name=&amp;quot;SC-21-88&amp;quot; /&amp;gt; The handbook also calls for station leak detection, emergency shutoff on a fault, and breakaway protection if the vehicle moves off with the nozzle connected.&amp;lt;ref name=&amp;quot;SC-21-88&amp;quot; /&amp;gt; Station relief valves are intended to protect vehicle storage against overpressure. The stated setting is 1.38 times nominal working pressure: 48.3 MPa for a 35 MPa system and 96.6 MPa for a 70 MPa system.&amp;lt;ref name=&amp;quot;SC-21-88&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Fuelling borrows its static protection from gasoline. The handbook describes a conductive path from the fuelling neck to the tyres and from the tyre contact surface to the station nozzle.&amp;lt;ref name=&amp;quot;SC-21-87&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;SC-21-88&amp;quot;&amp;gt;Scheffler and Collins (2008), p. 21-88.&amp;lt;/ref&amp;gt; This [[Bonding and grounding|bonding and grounding]] path reduces the risk of ignition by static sparks, and the countermeasure was adapted to hydrogen fuelling.&amp;lt;ref name=&amp;quot;SC-21-88&amp;quot; /&amp;gt; The handbook also calls for station leak detection, emergency shutoff on a fault, and breakaway protection if the vehicle moves off with the nozzle connected.&amp;lt;ref name=&amp;quot;SC-21-88&amp;quot; /&amp;gt; Station relief valves are intended to protect vehicle storage against overpressure. The stated setting is 1.38 times nominal working pressure: 48.3 MPa for a 35 MPa system and 96.6 MPa for a 70 MPa system.&amp;lt;ref name=&amp;quot;SC-21-88&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-deleted&quot;&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;[[File:fse-fuel-cell-vehicle-v4.svg|thumb|upright=1.5|alt=Horizontal bar chart of pressures for natural gas systems, hydrogen vehicle storage and hydrogen station relief settings|Pressures of natural gas and hydrogen fuelling systems, with station relief valve settings at 1.38 times the nominal working pressure. Based on Scheffler and Collins (2008), pp. 21-84 and 21-88, and Rivkin (2008b), pp. 21-69 and 21-74.]]&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Repair garages built to NFPA 30A, &amp;#039;&amp;#039;Code for Motor Fuel Dispensing Facilities and Repair Garages&amp;#039;&amp;#039;, were considered adequate for FCVs as long as nobody works on the hydrogen storage system.&amp;lt;ref name=&amp;quot;SC-21-88&amp;quot; /&amp;gt; Areas for such work need more. A vent system will probably be required to depressurise and purge the vehicle storage system before major repairs.&amp;lt;ref name=&amp;quot;SC-21-88&amp;quot; /&amp;gt; Ventilation, gas and fire detection, electrical classification, links between the ventilation system and other areas, and the fire rating of walls and doors should also be considered.&amp;lt;ref name=&amp;quot;SC-21-88&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Repair garages built to NFPA 30A, &amp;#039;&amp;#039;Code for Motor Fuel Dispensing Facilities and Repair Garages&amp;#039;&amp;#039;, were considered adequate for FCVs as long as nobody works on the hydrogen storage system.&amp;lt;ref name=&amp;quot;SC-21-88&amp;quot; /&amp;gt; Areas for such work need more. A vent system will probably be required to depressurise and purge the vehicle storage system before major repairs.&amp;lt;ref name=&amp;quot;SC-21-88&amp;quot; /&amp;gt; Ventilation, gas and fire detection, electrical classification, links between the ventilation system and other areas, and the fire rating of walls and doors should also be considered.&amp;lt;ref name=&amp;quot;SC-21-88&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;

&lt;!-- diff cache key firesb_pjbsiy42-wiki_:diff:1.41:old-4264:rev-5927:php=table --&gt;
&lt;/table&gt;</summary>
		<author><name>Peter</name></author>
	</entry>
	<entry>
		<id>https://fire-safety.academy/w/index.php?title=Fuel_cell_vehicle&amp;diff=4264&amp;oldid=prev</id>
		<title>Mark: FSE wiki: fact-check: qualify 2008 FCV design claims and hydrogen dilution example (written by Claude Opus 5.5)</title>
		<link rel="alternate" type="text/html" href="https://fire-safety.academy/w/index.php?title=Fuel_cell_vehicle&amp;diff=4264&amp;oldid=prev"/>
		<updated>2026-11-08T01:34:58Z</updated>

		<summary type="html">&lt;p&gt;FSE wiki: fact-check: qualify 2008 FCV design claims and hydrogen dilution example (written by Claude Opus 5.5)&lt;/p&gt;
&lt;a href=&quot;https://fire-safety.academy/w/index.php?title=Fuel_cell_vehicle&amp;amp;diff=4264&amp;amp;oldid=3225&quot;&gt;Show changes&lt;/a&gt;</summary>
		<author><name>Mark</name></author>
	</entry>
	<entry>
		<id>https://fire-safety.academy/w/index.php?title=Fuel_cell_vehicle&amp;diff=3225&amp;oldid=prev</id>
		<title>Mark: New FSE wiki article: Fuel cell vehicle (written by Claude Opus 5.5)</title>
		<link rel="alternate" type="text/html" href="https://fire-safety.academy/w/index.php?title=Fuel_cell_vehicle&amp;diff=3225&amp;oldid=prev"/>
		<updated>2026-11-07T21:15:38Z</updated>

		<summary type="html">&lt;p&gt;New FSE wiki article: Fuel cell vehicle (written by Claude Opus 5.5)&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;A &amp;#039;&amp;#039;&amp;#039;fuel cell vehicle&amp;#039;&amp;#039;&amp;#039; (&amp;#039;&amp;#039;&amp;#039;FCV&amp;#039;&amp;#039;&amp;#039;) is an electric vehicle in which a fuel cell turns hydrogen carried on board into electric power for the traction motors. The fuel cell works like a battery, except that it does not consume stored chemical energy but produces power continuously from a supply of hydrogen.&amp;lt;ref name=&amp;quot;SC-21-78&amp;quot;&amp;gt;Scheffler and Collins (2008), p. 21-78.&amp;lt;/ref&amp;gt; A hydrogen fuel cell vehicle emits only steam from its exhaust.&amp;lt;ref name=&amp;quot;SC-21-77&amp;quot;&amp;gt;Scheffler and Collins (2008), p. 21-77.&amp;lt;/ref&amp;gt; In the 20th edition of the NFPA &amp;#039;&amp;#039;Fire Protection Handbook&amp;#039;&amp;#039; (2008), FCVs were demonstration vehicles; about 300 fuel cell cars and buses were expected in California by 2007.&amp;lt;ref name=&amp;quot;SC-21-77&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
A typical FCV carries about 6 kg of hydrogen as compressed gas at 350 bar (35 MPa), with manufacturers moving to 700 bar, and its electric drive runs at 300 V to 600 V.&amp;lt;ref name=&amp;quot;SC-21-84&amp;quot;&amp;gt;Scheffler and Collins (2008), p. 21-84.&amp;lt;/ref&amp;gt;&amp;lt;ref name=&amp;quot;SC-21-82&amp;quot;&amp;gt;Scheffler and Collins (2008), p. 21-82.&amp;lt;/ref&amp;gt; The fire hazards therefore come from two sources: a gas with a very wide flammable range and an often invisible flame, and a high-voltage electrical system.&amp;lt;ref name=&amp;quot;Lemoff-6-181&amp;quot;&amp;gt;Lemoff (2008), p. 6-181.&amp;lt;/ref&amp;gt;&amp;lt;ref name=&amp;quot;SC-21-83&amp;quot;&amp;gt;Scheffler and Collins (2008), p. 21-83.&amp;lt;/ref&amp;gt; Vehicle designers counter them with fail-safe valves and disconnects, managed hydrogen discharges, and pressure relief devices that vent the hydrogen in a fire so that the container does not burst.&amp;lt;ref name=&amp;quot;SC-21-80&amp;quot;&amp;gt;Scheffler and Collins (2008), p. 21-80.&amp;lt;/ref&amp;gt;&amp;lt;ref name=&amp;quot;SC-21-85&amp;quot;&amp;gt;Scheffler and Collins (2008), p. 21-85.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== Principle and main components ==&lt;br /&gt;
A [[Fuel cell]] has two electrodes, an anode and a cathode, separated by an electrolyte. Unlike a battery, it stores its fuel and oxidant outside the cell, so it keeps operating as long as both are replenished.&amp;lt;ref name=&amp;quot;Biggins-8-108&amp;quot;&amp;gt;Biggins (2008), p. 8-108.&amp;lt;/ref&amp;gt; Almost all prototype fuel cell cars and buses use proton exchange membrane (PEM) fuel cells. Each cell is a thin wafer: a catalyst-coated membrane enclosed in electrically conducting graphite or metal plates.&amp;lt;ref name=&amp;quot;SC-21-81&amp;quot;&amp;gt;Scheffler and Collins (2008), p. 21-81.&amp;lt;/ref&amp;gt; At the anode, hydrogen atoms release their electrons and become protons, which pass through the membrane to the cathode. There they combine with oxygen from the air and with the electrons, which have flowed through the external circuit, to form water.&amp;lt;ref name=&amp;quot;SC-21-81&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Cells are assembled in stacks to give enough power and voltage for the drive system; stacks of 50 kW to 150 kW powered prototype cars, minivans and transit buses.&amp;lt;ref name=&amp;quot;SC-21-81&amp;quot; /&amp;gt; The rest of the fuel cell system, the balance of plant, delivers hydrogen to the stack, supplies fresh air to the cathodes and manages stack temperature and water.&amp;lt;ref name=&amp;quot;SC-21-81&amp;quot; /&amp;gt; A power control turns the driver&amp;#039;s throttle input into electric power for the drive motors.&amp;lt;ref name=&amp;quot;SC-21-78&amp;quot; /&amp;gt; Many FCVs are hybrids that recover braking energy and store it in batteries or ultracapacitors. Some carry a separate small fuel cell, an auxiliary power unit of typically 3 kW to 10 kW, for systems such as radios and air conditioning.&amp;lt;ref name=&amp;quot;SC-21-78&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
The case for FCVs rests on efficiency and emissions. An internal combustion engine converts on average only about 16 % of the energy in gasoline into motion of the wheels, whereas FCVs can exceed 50 %.&amp;lt;ref name=&amp;quot;SC-21-78&amp;quot; /&amp;gt; The exhaust contains no pollutants, although producing the hydrogen does cause some emissions.&amp;lt;ref name=&amp;quot;SC-21-77&amp;quot; /&amp;gt; Fuel cell types are named after their electrolyte. Phosphoric acid cells operate at about 200 °C and solid oxide cells at about 1,000 °C, while polymer electrolyte cells run cooler and were mainly used in mobile applications.&amp;lt;ref name=&amp;quot;Biggins-8-109&amp;quot;&amp;gt;Biggins (2008), p. 8-109.&amp;lt;/ref&amp;gt; In stationary use, the high operating temperatures of some fuel cells can ignite nearby combustibles, and the fuel is often a flammable gas or liquid.&amp;lt;ref name=&amp;quot;Biggins-8-109&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
FCVs range from 12.2 m (40 ft) transit buses down to motor scooters and fork-lift trucks.&amp;lt;ref name=&amp;quot;SC-21-78&amp;quot; /&amp;gt; Transit buses were seen as a good early market because they have well-defined duty cycles, central fuelling and maintenance, and dedicated maintenance staff.&amp;lt;ref name=&amp;quot;SC-21-79&amp;quot;&amp;gt;Scheffler and Collins (2008), p. 21-79.&amp;lt;/ref&amp;gt; As a hydrogen-fuelled vehicle, an FCV is one kind of [[Alternative fuel vehicle|alternative fuel vehicle]], since United States law lists hydrogen among the alternative fuels.&amp;lt;ref name=&amp;quot;Rivkin-21-41&amp;quot;&amp;gt;Rivkin (2008b), p. 21-41.&amp;lt;/ref&amp;gt; Most hydrogen vehicles are fuel cell powered; the few that burn hydrogen in an internal combustion engine present hazards similar to those of natural gas vehicles.&amp;lt;ref name=&amp;quot;Rivkin-21-73&amp;quot;&amp;gt;Rivkin (2008b), p. 21-73.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== Hydrogen storage on board ==&lt;br /&gt;
Hydrogen can be carried as compressed gas, as liquid, in reversible metal hydrides or as a chemical hydride. It can also be produced on board from hydrocarbon fuels or alcohol. All these methods have been demonstrated, but most FCVs use compressed hydrogen stored at high pressure in containers on the vehicle.&amp;lt;ref name=&amp;quot;SC-21-78&amp;quot; /&amp;gt; The technical challenge is to carry enough gas for a reasonable driving range. A typical FCV needs about 6 kg of hydrogen, which is why manufacturers were raising storage pressures from 350 bar to 700 bar (5,000 psig to 10,000 psig).&amp;lt;ref name=&amp;quot;SC-21-84&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
The storage system has four main functions. A filling receptacle, for example to SAE J2600, contains a check valve that prevents backflow when the nozzle is disconnected, and a second check valve usually provides redundancy.&amp;lt;ref name=&amp;quot;SC-21-84&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;SC-21-85&amp;quot; /&amp;gt; One or more containers hold the gas, and shutoff valves and pressure regulators control its delivery to the fuel cells, as on compressed natural gas vehicles. One or more pressure relief devices prevent the tank from bursting if the system is exposed to a fire.&amp;lt;ref name=&amp;quot;SC-21-85&amp;quot; /&amp;gt; The containers draw on experience with compressed natural gas and are designed to contain hydrogen and not burst.&amp;lt;ref name=&amp;quot;SC-21-85&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Compressed hydrogen cylinders are protected against overpressure by frangible (bursting) discs, alone or combined with fusible plugs. Because they contain no liquid, they are not subject to a [[BLEVE|boiling liquid expanding vapour explosion]], although they can still fail.&amp;lt;ref name=&amp;quot;Lemoff-6-181&amp;quot; /&amp;gt; For identification, SAE recommended a blue diamond label like the one used on natural gas vehicles, marked with compressed hydrogen or the other storage method used.&amp;lt;ref name=&amp;quot;SC-21-85&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
FCVs need clean hydrogen, and the industry was aiming for less than 1,000 ppm of impurities.&amp;lt;ref name=&amp;quot;SC-21-86&amp;quot;&amp;gt;Scheffler and Collins (2008), p. 21-86.&amp;lt;/ref&amp;gt; For this reason the fuel is not odorised, unlike natural gas. An odorant would either damage fuel cell components or pass through the cell and be concentrated up to 500 times in the exhaust, masking any real leak.&amp;lt;ref name=&amp;quot;SC-21-87&amp;quot;&amp;gt;Scheffler and Collins (2008), p. 21-87.&amp;lt;/ref&amp;gt; In liquid hydrogen all compounds except helium freeze, so an odorant would stay behind while the hydrogen leaked out.&amp;lt;ref name=&amp;quot;SC-21-87&amp;quot; /&amp;gt; Hydrogen delivered by pipeline with an odorant should therefore be deodorised before it is dispensed.&amp;lt;ref name=&amp;quot;SC-21-87&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== Hydrogen properties and release behaviour ==&lt;br /&gt;
Hydrogen has an extremely wide flammable range, from about 4 % to 75 % by volume in air, and the highest burning velocity of any gas.&amp;lt;ref name=&amp;quot;Lemoff-6-181&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;Rivkin-21-55&amp;quot;&amp;gt;Rivkin (2008b), p. 21-55.&amp;lt;/ref&amp;gt; Its ignition temperature is reasonably high, but its ignition energy is very low, and with a density of only 0.07 relative to air it disperses rapidly.&amp;lt;ref name=&amp;quot;Lemoff-6-181&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;Rivkin-21-55&amp;quot; /&amp;gt; Because it contains no carbon, it burns with a nonluminous flame that is often invisible in daylight and gives off little thermal radiation, so people can walk into it unaware.&amp;lt;ref name=&amp;quot;Lemoff-6-181&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;Lemoff-6-182&amp;quot;&amp;gt;Lemoff (2008), p. 6-182.&amp;lt;/ref&amp;gt; For [[Hydrogen safety|hydrogen safety]] these properties work in both directions. The wide flammable range and high burning rate accentuate the hazard, while the low ignition energy, low heat of combustion per unit volume and low-radiation flame counteract it in many cases.&amp;lt;ref name=&amp;quot;Lemoff-6-181&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
How a release behaves depends on its pressure. When gaseous hydrogen escapes at high pressure, small heat sources such as friction or static electricity can ignite it promptly, so it often behaves as if it were self-igniting. Such releases usually lead to fires rather than explosions.&amp;lt;ref name=&amp;quot;Lemoff-6-181&amp;quot; /&amp;gt; At low pressure self-ignition is unlikely. Instead, an accumulated cloud can explode with a very rapid pressure rise that is extremely difficult to vent.&amp;lt;ref name=&amp;quot;Lemoff-6-181&amp;quot; /&amp;gt; Escaping hydrogen gas seldom leaves a situation without fire, because it either ignites promptly or rises rapidly.&amp;lt;ref name=&amp;quot;Lemoff-6-182&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Whether a discharge from a vehicle can burn depends on how it mixes with air. A mixture of hydrogen, oxygen and nitrogen is potentially flammable when it contains more than 4 % hydrogen and more than 5 % oxygen by volume.&amp;lt;ref name=&amp;quot;SC-21-86&amp;quot; /&amp;gt; A discharge already diluted to 5 % hydrogen with inert gas never becomes flammable, because its hydrogen falls below 4 % before the oxygen reaches 5 %. Pure hydrogen, in contrast, passes through a flammable mixture as it disperses.&amp;lt;ref name=&amp;quot;SC-21-86&amp;quot; /&amp;gt; The 4 % limit comes from tests on uniform, quiescent mixtures. Tests on discharges have shown that flow and mixing can suppress ignition, and that more than 8 % hydrogen is typically needed to ignite them.&amp;lt;ref name=&amp;quot;SC-21-86&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
An ignited release from a small opening forms a [[Jet fire]]. The SFPE Handbook gives an example for hydrogen flowing from a 5 mm nozzle out of a reservoir at 300 kPa.&amp;lt;ref name=&amp;quot;Heskestad-2-5&amp;quot;&amp;gt;Heskestad (2002), p. 2-5.&amp;lt;/ref&amp;gt; The flow is choked at 3.65 g/s, the heat release rate is 436 kW, and the flame is about 239 nozzle diameters long, or about 1.2 m.&amp;lt;ref name=&amp;quot;Heskestad-2-5&amp;quot; /&amp;gt; In this momentum-dominated regime the flame length is proportional to the opening diameter for a given gas and discharge density.&amp;lt;ref name=&amp;quot;Heskestad-2-4&amp;quot;&amp;gt;Heskestad (2002), pp. 2-4–2-5.&amp;lt;/ref&amp;gt; Vehicle storage pressures are more than a hundred times higher than in this example, so it shows the scaling, not the flame length from a vehicle leak.&amp;lt;ref name=&amp;quot;SC-21-84&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== Hydrogen quantities: worked example ==&lt;br /&gt;
Three simple relations show what the hydrogen on board means for fire safety. The volume of the gas at ambient conditions is its mass divided by its density. The minimum volume of air needed to dilute that gas below its lower flammable limit follows from the method Slye (2008) gives for flammable vapours: (100 − LFL) volumes of air per LFL volumes of gas.&amp;lt;ref name=&amp;quot;Slye-6-202&amp;quot;&amp;gt;Slye (2008), p. 6-202.&amp;lt;/ref&amp;gt; The chemical energy stored is the mass multiplied by the heat of combustion.&amp;lt;ref name=&amp;quot;Heskestad-2-5&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;math display=&amp;quot;block&amp;quot;&amp;gt;V_\mathrm{g} = \frac{m}{\rho}&amp;lt;/math&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;math display=&amp;quot;block&amp;quot;&amp;gt;V_\mathrm{air} = V_\mathrm{g} \, \frac{100 - \mathrm{LFL}}{\mathrm{LFL}}&amp;lt;/math&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;math display=&amp;quot;block&amp;quot;&amp;gt;E = m \, \Delta H_\mathrm{c}&amp;lt;/math&amp;gt;&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
! Symbol !! Description !! Unit&lt;br /&gt;
|-&lt;br /&gt;
| &amp;lt;math&amp;gt;m&amp;lt;/math&amp;gt; || Mass of hydrogen || kg&lt;br /&gt;
|-&lt;br /&gt;
| &amp;lt;math&amp;gt;\rho&amp;lt;/math&amp;gt; || Density of hydrogen at ambient temperature and pressure || kg/m³&lt;br /&gt;
|-&lt;br /&gt;
| &amp;lt;math&amp;gt;V_\mathrm{g}&amp;lt;/math&amp;gt; || Volume of the hydrogen at ambient conditions || m³&lt;br /&gt;
|-&lt;br /&gt;
| &amp;lt;math&amp;gt;\mathrm{LFL}&amp;lt;/math&amp;gt; || Lower flammable limit of hydrogen in air || % by volume&lt;br /&gt;
|-&lt;br /&gt;
| &amp;lt;math&amp;gt;V_\mathrm{air}&amp;lt;/math&amp;gt; || Minimum volume of air to dilute the hydrogen below the lower flammable limit || m³&lt;br /&gt;
|-&lt;br /&gt;
| &amp;lt;math&amp;gt;\Delta H_\mathrm{c}&amp;lt;/math&amp;gt; || Heat of combustion of hydrogen || MJ/kg&lt;br /&gt;
|-&lt;br /&gt;
| &amp;lt;math&amp;gt;E&amp;lt;/math&amp;gt; || Chemical energy of the stored hydrogen || MJ&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
As a worked example, take the typical on-board quantity of 6 kg.&amp;lt;ref name=&amp;quot;SC-21-84&amp;quot; /&amp;gt; With a density of 0.083 kg/m³ at ambient temperature and pressure, it occupies 6 / 0.083 = 72.3 m³.&amp;lt;ref name=&amp;quot;Heskestad-2-5&amp;quot; /&amp;gt; To keep all of it below the lower flammable limit of 4 %, it would need at least 72.3 × 96 / 4 = 1,735 m³, or about 1,740 m³ of air.&amp;lt;ref name=&amp;quot;SC-21-86&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;Slye-6-202&amp;quot; /&amp;gt; With a heat of combustion of 120 MJ/kg, the 6 kg holds 720 MJ of chemical energy.&amp;lt;ref name=&amp;quot;Heskestad-2-5&amp;quot; /&amp;gt; Using the lower heating value and density of gasoline in the handbook, this equals the energy of about 16 kg to 17 kg, or 21 L to 24 L, of gasoline.&amp;lt;ref name=&amp;quot;Rivkin-21-56&amp;quot;&amp;gt;Rivkin (2008b), p. 21-56 (Table 21.4.14).&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
The dilution estimate assumes complete, uniform mixing, which never occurs in practice, so it is a lower bound and not a ventilation design value.&amp;lt;ref name=&amp;quot;Slye-6-203&amp;quot;&amp;gt;Slye (2008), pp. 6-202–6-203.&amp;lt;/ref&amp;gt; Hydrogen&amp;#039;s high diffusion rate also makes it difficult for the gas to accumulate in ordinary buildings unless it escapes quickly.&amp;lt;ref name=&amp;quot;Lemoff-6-182&amp;quot; /&amp;gt; On the other hand, the tests on vehicle discharges suggest that real jets often need more than 8 % hydrogen to ignite.&amp;lt;ref name=&amp;quot;SC-21-86&amp;quot; /&amp;gt; For garages and other structures, the SAE approach combines analysis with tests on the vehicle.&amp;lt;ref name=&amp;quot;SC-21-86&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== Vehicle safety design ==&lt;br /&gt;
The vehicles are designed so that foreseeable single-point hardware or software failures do not create an unreasonable risk or uncontrolled vehicle behaviour.&amp;lt;ref name=&amp;quot;SC-21-80&amp;quot; /&amp;gt; This calls for redundant safety features or, where redundancy is not possible, a high safety factor, as for a pressure vessel. Failure modes and effects analysis (FMEA) is the standard tool, and separating hazards prevents failures from cascading.&amp;lt;ref name=&amp;quot;SC-21-80&amp;quot; /&amp;gt; The design is fail-safe: electrical disconnects open and fuel shutoff valves close when they lose power. Any interruption of the control signal, by accident, equipment failure or human error, therefore isolates the electrical and fuel sources.&amp;lt;ref name=&amp;quot;SC-21-80&amp;quot; /&amp;gt; When crash sensors detect a collision, the fuel is normally shut off and the electrical system disconnected automatically.&amp;lt;ref name=&amp;quot;SC-21-81&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Hydrogen discharges are managed so that the vehicle can be used like a gasoline car. Under SAE J2578, discharges into compartments that may contain ignition sources must be rendered nonflammable.&amp;lt;ref name=&amp;quot;SC-21-85&amp;quot; /&amp;gt; The passenger compartment is kept nonhazardous by barriers, by dilution or by catalytic recombiners that remove hydrogen. A leak beyond these countermeasures triggers a staged warning and shutdown.&amp;lt;ref name=&amp;quot;SC-21-85&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
The local region where a discharge mixes with air should be unignitible at all times.&amp;lt;ref name=&amp;quot;SC-21-85&amp;quot; /&amp;gt; An SAE approach uses analysis and tests to verify that the atmosphere around a parked or operating vehicle stays unclassified for [[Hazardous area classification|hazardous area classification]] under Article 500 of NFPA 70. FCVs can then be parked in residential garages and ventilated commercial buildings without changes to building codes.&amp;lt;ref name=&amp;quot;SC-21-86&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
The electric drive operates at typically 300 V to 600 V and borrows its safety measures from electric and hybrid vehicles.&amp;lt;ref name=&amp;quot;SC-21-82&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;SC-21-83&amp;quot; /&amp;gt; Unlike low-voltage circuits, the high-voltage circuits are isolated from the chassis, so touching them at any single point does not give a shock. Interlocks or special fasteners prevent access to live parts, and fuses protect against overcurrent.&amp;lt;ref name=&amp;quot;SC-21-83&amp;quot; /&amp;gt; High-voltage cables have a permanent orange covering, and compartments carry a black-on-yellow high-voltage symbol. Automatic and manual disconnects can isolate both poles of the fuel cell stack, the traction battery and other high-voltage sources.&amp;lt;ref name=&amp;quot;SC-21-83&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;SC-21-84&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== Fuelling and maintenance ==&lt;br /&gt;
Hydrogen fuelling stations typically store the gas on site, often as a cryogenic liquid that is warmed back into gas before use.&amp;lt;ref name=&amp;quot;Rivkin-21-74&amp;quot;&amp;gt;Rivkin (2008b), p. 21-74.&amp;lt;/ref&amp;gt; They work at higher pressures than natural gas stations: up to 69 MPa (10,000 psi), against 20.7 MPa to 27.6 MPa (3,000 psi to 4,000 psi) for natural gas.&amp;lt;ref name=&amp;quot;Rivkin-21-74&amp;quot; /&amp;gt; The low density of hydrogen requires these high tank pressures to store enough fuel for a practical driving range.&amp;lt;ref name=&amp;quot;Rivkin-21-74&amp;quot; /&amp;gt; In 2008 the California Hydrogen Highway plan aimed for a network of stations along the state&amp;#039;s interstate highways by 2010.&amp;lt;ref name=&amp;quot;SC-21-87&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Fuelling borrows its static protection from gasoline. A vehicle keeps a conductive path from the fuelling neck to the tyres, and the station keeps one from the tyre contact surface to the nozzle.&amp;lt;ref name=&amp;quot;SC-21-87&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;SC-21-88&amp;quot;&amp;gt;Scheffler and Collins (2008), p. 21-88.&amp;lt;/ref&amp;gt; This [[Bonding and grounding|bonding and grounding]] path prevents sparks during filling, and the same countermeasures have been adapted to hydrogen.&amp;lt;ref name=&amp;quot;SC-21-88&amp;quot; /&amp;gt; The station also provides leak detection, an emergency shutoff if a fault is detected, and breakaway protection if the vehicle moves off with the nozzle connected.&amp;lt;ref name=&amp;quot;SC-21-88&amp;quot; /&amp;gt; Relief valves on the station protect the vehicle storage system against overpressure. They are set to 1.38 times the nominal working pressure, which for 35 MPa and 70 MPa systems means 48.3 MPa and 96.6 MPa.&amp;lt;ref name=&amp;quot;SC-21-88&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Repair garages built to NFPA 30A, &amp;#039;&amp;#039;Code for Motor Fuel Dispensing Facilities and Repair Garages&amp;#039;&amp;#039;, were considered adequate for FCVs as long as nobody works on the hydrogen storage system.&amp;lt;ref name=&amp;quot;SC-21-88&amp;quot; /&amp;gt; Areas for such work need more. A vent system will probably be required to depressurise and purge the vehicle storage system before major repairs.&amp;lt;ref name=&amp;quot;SC-21-88&amp;quot; /&amp;gt; Ventilation, gas and fire detection, electrical classification, links between the ventilation system and other areas, and the fire rating of walls and doors should also be considered.&amp;lt;ref name=&amp;quot;SC-21-88&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== Crash, fire and emergency response ==&lt;br /&gt;
In United States [[Motor vehicle fire|motor vehicle fire]] data, about 1.2 % (385) of the roughly 32,000 passenger vehicle occupants killed each year in traffic accidents died in post-collision fires. These fires are either fuel-fed or start in the engine compartment.&amp;lt;ref name=&amp;quot;Long-21-5&amp;quot;&amp;gt;Long et al. (2008), p. 21-5.&amp;lt;/ref&amp;gt; FCVs were expected to be at least as crashworthy as other vehicles. The SAE identified two keys to safety after a crash: nobody may be exposed to electric shock, and the hydrogen must stay contained.&amp;lt;ref name=&amp;quot;SC-21-88&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
In a crash, the hydrogen shutoff valves at the containers typically close and isolate the system. Only a small amount of gas remains downstream, whose energy is typically less than that of the fuel lines of a gasoline vehicle.&amp;lt;ref name=&amp;quot;SC-21-85&amp;quot; /&amp;gt; If the vehicle is then exposed to fire, from the crash or from another burning vehicle, the pressure relief devices activate thermally. They release the hydrogen so that the container does not burst, a practice adopted from natural gas vehicles.&amp;lt;ref name=&amp;quot;SC-21-85&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;SC-21-88&amp;quot; /&amp;gt; High-voltage circuits must be discharged or isolated from ground, so that they can be touched without a harmful shock.&amp;lt;ref name=&amp;quot;SC-21-88&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
For responders the main difficulty is that a hydrogen flame may be invisible. The handbook describes holding a broom out in front while advancing slowly and throwing dirt ahead; the particles glow and show the edge of the flame.&amp;lt;ref name=&amp;quot;Lemoff-6-182&amp;quot; /&amp;gt; Water should be applied to fire-exposed containers, and the flow of gas stopped if possible.&amp;lt;ref name=&amp;quot;Lemoff-6-182&amp;quot; /&amp;gt; A Dutch guidance document on car parks notes that the incident response risks of hydrogen cars can be as complex as those of [[Electric vehicle fire|electric vehicle fires]].&amp;lt;ref name=&amp;quot;VdG-19&amp;quot;&amp;gt;Van der Graaf et al. (2021/2023), p. 19.&amp;lt;/ref&amp;gt; It calls for more research into the flame egress and thermal load on car park structures of fires in hydrogen or natural gas vehicles.&amp;lt;ref name=&amp;quot;VdG-55&amp;quot;&amp;gt;Van der Graaf et al. (2021/2023), p. 55.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== Limits of the evidence ==&lt;br /&gt;
The handbook chapter on FCVs was written with contributions from members of the United States fuel cell industry association, at a time when the vehicles were still in demonstration.&amp;lt;ref name=&amp;quot;SC-21-77&amp;quot; /&amp;gt; Its safety conclusions rest partly on studies it quotes, such as a 1997 Ford study for the Department of Energy. That study judged an FCV potentially safer than gasoline or propane vehicles and equal to or better than natural gas vehicles.&amp;lt;ref name=&amp;quot;SC-21-85&amp;quot; /&amp;gt; Many of the SAE standards it describes, including the test methods for discharges and crashes, were still being developed.&amp;lt;ref name=&amp;quot;SC-21-86&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;SC-21-88&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
The source documents contain no fire test data for fuel cell vehicles. The Dutch car park guidance leaves hydrogen vehicles out of its scope because they were still rare, and refers to a separate report that is not among the sources.&amp;lt;ref name=&amp;quot;VdG-19&amp;quot; /&amp;gt; The handbook chapters also differ on the density of hydrogen relative to air, giving 0.07 and 0.1.&amp;lt;ref name=&amp;quot;Rivkin-21-55&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;Biggins-8-110&amp;quot;&amp;gt;Biggins (2008), p. 8-110.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== See also ==&lt;br /&gt;
* [[Car park fire]]&lt;br /&gt;
* [[Commercial vehicle fire]]&lt;br /&gt;
* [[Lithium-ion battery fire]]&lt;br /&gt;
* [[Motor fuel dispensing facility]]&lt;br /&gt;
&lt;br /&gt;
== Notes ==&lt;br /&gt;
&amp;lt;references /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== References ==&lt;br /&gt;
* Biggins, J. B. (2008). Stationary combustion engines and fuel cells. In A. E. Cote, C. C. Grant, J. R. Hall Jr., &amp;amp; R. E. Solomon (Eds.), &amp;#039;&amp;#039;Fire protection handbook&amp;#039;&amp;#039; (20th ed., pp. 8-105–8-111). National Fire Protection Association.&lt;br /&gt;
* Heskestad, G. (2002). Fire plumes, flame height, and air entrainment. In P. J. DiNenno, D. Drysdale, C. L. Beyler, W. D. Walton, R. L. P. Custer, J. R. Hall Jr., &amp;amp; J. M. Watts Jr. (Eds.), &amp;#039;&amp;#039;SFPE handbook of fire protection engineering&amp;#039;&amp;#039; (3rd ed., pp. 2-1–2-17). National Fire Protection Association; Society of Fire Protection Engineers.&lt;br /&gt;
* Lemoff, T. C. (2008). Gases. In A. E. Cote, C. C. Grant, J. R. Hall Jr., &amp;amp; R. E. Solomon (Eds.), &amp;#039;&amp;#039;Fire protection handbook&amp;#039;&amp;#039; (20th ed., pp. 6-165–6-186). National Fire Protection Association.&lt;br /&gt;
* Long, R. T., Jr., Colwell, J. D., Ray, R., Grossman, H. L., Thomas, B., &amp;amp; Strassburger, R. (2008). Passenger vehicle fires. In A. E. Cote, C. C. Grant, J. R. Hall Jr., &amp;amp; R. E. Solomon (Eds.), &amp;#039;&amp;#039;Fire protection handbook&amp;#039;&amp;#039; (20th ed., pp. 21-3–21-14). National Fire Protection Association.&lt;br /&gt;
* Rivkin, C. H. (2008b). Vehicle fueling using gaseous fuels. In A. E. Cote, C. C. Grant, J. R. Hall Jr., &amp;amp; R. E. Solomon (Eds.), &amp;#039;&amp;#039;Fire protection handbook&amp;#039;&amp;#039; (20th ed., pp. 21-41–21-76). National Fire Protection Association.&lt;br /&gt;
* Scheffler, G. W., &amp;amp; Collins, W. P. (2008). Fuel cell vehicles. In A. E. Cote, C. C. Grant, J. R. Hall Jr., &amp;amp; R. E. Solomon (Eds.), &amp;#039;&amp;#039;Fire protection handbook&amp;#039;&amp;#039; (20th ed., pp. 21-77–21-89). National Fire Protection Association.&lt;br /&gt;
* Slye, O. M., Jr. (2008). Flammable and combustible liquids. In A. E. Cote, C. C. Grant, J. R. Hall Jr., &amp;amp; R. E. Solomon (Eds.), &amp;#039;&amp;#039;Fire protection handbook&amp;#039;&amp;#039; (20th ed., pp. 6-197–6-208). National Fire Protection Association.&lt;br /&gt;
* Van der Graaf, J., Hessels, T., &amp;amp; Rosmuller, N. (2023). &amp;#039;&amp;#039;Fire safety of indoor car parks accommodating electrically powered vehicles&amp;#039;&amp;#039;. Nederlands Instituut Publieke Veiligheid. (Original work published 2021)&lt;br /&gt;
&lt;br /&gt;
[[Category:Special Hazards &amp;amp; Building Types]]&lt;/div&gt;</summary>
		<author><name>Mark</name></author>
	</entry>
</feed>