<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://fire-safety.academy/w/index.php?action=history&amp;feed=atom&amp;title=Firestopping</id>
	<title>Firestopping - Revision history</title>
	<link rel="self" type="application/atom+xml" href="https://fire-safety.academy/w/index.php?action=history&amp;feed=atom&amp;title=Firestopping"/>
	<link rel="alternate" type="text/html" href="https://fire-safety.academy/w/index.php?title=Firestopping&amp;action=history"/>
	<updated>2026-11-04T13:15:43Z</updated>
	<subtitle>Revision history for this page on the wiki</subtitle>
	<generator>MediaWiki 1.43.11</generator>
	<entry>
		<id>https://fire-safety.academy/w/index.php?title=Firestopping&amp;diff=2819&amp;oldid=prev</id>
		<title>Emma: Revise Basic article against FSE writing guidelines: sourced explanations, examples and references (GPT-6)</title>
		<link rel="alternate" type="text/html" href="https://fire-safety.academy/w/index.php?title=Firestopping&amp;diff=2819&amp;oldid=prev"/>
		<updated>2026-11-02T18:42:18Z</updated>

		<summary type="html">&lt;p&gt;Revise Basic article against FSE writing guidelines: sourced explanations, examples and references (GPT-6)&lt;/p&gt;
&lt;table style=&quot;background-color: #fff; color: #202122;&quot; data-mw=&quot;interface&quot;&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;tr class=&quot;diff-title&quot; lang=&quot;en&quot;&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;← Older revision&lt;/td&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;Revision as of 19:42, 2 November 2026&lt;/td&gt;
				&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l7&quot;&gt;Line 7:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 7:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== The route being sealed ==&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== The route being sealed ==&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Services often need to cross the walls or floors that form [[Fire compartmentation]]. Pipes, cables, cable trays and ventilation ducts can create openings through an otherwise continuous boundary&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;. A &lt;/del&gt;penetration seal addresses the route around those services. Its purpose is to preserve the intended separating function of the construction.&amp;lt;ref name=&quot;N_F-44&quot; /&amp;gt;&amp;lt;ref name=&quot;N_17-8&quot;&amp;gt;Iqbal and Salley (2004), p. 17-8.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Services often need to cross the walls or floors that form [[Fire compartmentation]]. Pipes, cables, cable trays and ventilation ducts can create openings through an otherwise continuous boundary&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;, and a &lt;/ins&gt;penetration seal addresses the route around those services. Its purpose is to preserve the intended separating function of the construction.&amp;lt;ref name=&quot;N_F-44&quot; /&amp;gt;&amp;lt;ref name=&quot;N_17-8&quot;&amp;gt;Iqbal and Salley (2004), p. 17-8.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;New Zealand&#039;s C/VM2, second edition of 2025, defines a fire stop as a material or construction method restricting spread within or through a fire separation. Its definition includes sealing around penetrations and narrow gaps between building elements&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;. The &lt;/del&gt;stated fire resistance must be no less than that of the separation. This is a requirement within that New Zealand method.&amp;lt;ref name=&quot;CVM_65&quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;New Zealand&#039;s C/VM2, second edition of 2025, defines a fire stop as a material or construction method restricting spread within or through a fire separation. Its definition includes sealing around penetrations and narrow gaps between building elements&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;, and the &lt;/ins&gt;stated fire resistance must be no less than that of the separation. This is a requirement within that New Zealand method.&amp;lt;ref name=&quot;CVM_65&quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[[File:fse-firestopping-v1.svg|thumb|upright=1.5|alt=Unsealed tray carrying flame and sealed penetration blocking it, with backing and contact shown.|Firestopping closes service paths through a fire separation. Based on Ministry of Business, Innovation and Employment (2025), p. 65.]]&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[[File:fse-firestopping-v1.svg|thumb|upright=1.5|alt=Unsealed tray carrying flame and sealed penetration blocking it, with backing and contact shown.|Firestopping closes service paths through a fire separation. Based on Ministry of Business, Innovation and Employment (2025), p. 65.]]&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;A visible gap and heat transmission through intact construction are different paths&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;. The &lt;/del&gt;International Fire Engineering Guidelines distinguish failed firestopping from excessive conduction through a barrier. Sealing an opening addresses the first mechanism but does not independently establish the thermal performance of the entire wall. The required functions remain those of the completed separation.&amp;lt;ref name=&quot;IFEG_1.6-7&quot; /&amp;gt;&amp;lt;ref name=&quot;KH_1-155&quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;A visible gap and heat transmission through intact construction are different paths&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;; the &lt;/ins&gt;International Fire Engineering Guidelines distinguish failed firestopping from excessive conduction through a barrier. Sealing an opening addresses the first mechanism but does not independently establish the thermal performance of the entire wall. The required functions remain those of the completed separation.&amp;lt;ref name=&quot;IFEG_1.6-7&quot; /&amp;gt;&amp;lt;ref name=&quot;KH_1-155&quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The surrounding construction matters to the seal&amp;#039;s performance. C/VM2&amp;#039;s construction commentary specifies proprietary products appropriate to the orientation and separating element. An installation in a floor and one in a wall are therefore not assumed interchangeable merely because their materials look similar. The evidence follows the application and construction in which the product is used.&amp;lt;ref name=&amp;quot;CVM_13&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The surrounding construction matters to the seal&amp;#039;s performance. C/VM2&amp;#039;s construction commentary specifies proprietary products appropriate to the orientation and separating element. An installation in a floor and one in a wall are therefore not assumed interchangeable merely because their materials look similar. The evidence follows the application and construction in which the product is used.&amp;lt;ref name=&amp;quot;CVM_13&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l19&quot;&gt;Line 19:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 19:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Materials and complete systems ==&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Materials and complete systems ==&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;A firestop is defined by the function of its installed arrangement&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;. The &lt;/del&gt;opening, service and surrounding separation form part of that arrangement. Iqbal and Salley&#039;s penetration-seal definition expressly includes wiring, cables, pipes, ducts and building joints. The same material name does not establish performance across all those geometries and duties.&amp;lt;ref name=&quot;N_F-44&quot; /&amp;gt;&amp;lt;ref name=&quot;CVM_13&quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;A firestop is defined by the function of its installed arrangement&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;: the &lt;/ins&gt;opening, service and surrounding separation form part of that arrangement. Iqbal and Salley&#039;s penetration-seal definition expressly includes wiring, cables, pipes, ducts and building joints. The same material name does not establish performance across all those geometries and duties.&amp;lt;ref name=&quot;N_F-44&quot; /&amp;gt;&amp;lt;ref name=&quot;CVM_13&quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;An [[Intumescent material]] expands when heated and can develop an insulating layer. Van Rossum identifies swelling as a process that changes thickness and heat transfer during fire&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;. This &lt;/del&gt;explains one possible protective-material mechanism. It does not establish a universal expansion factor, seal depth or application for an unspecified firestop product.&amp;lt;ref name=&quot;VR_5.2&quot;&amp;gt;Van Rossum (2027), §5.2.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;An [[Intumescent material]] expands when heated and can develop an insulating layer. Van Rossum identifies swelling as a process that changes thickness and heat transfer during fire&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;, and this &lt;/ins&gt;explains one possible protective-material mechanism. It does not establish a universal expansion factor, seal depth or application for an unspecified firestop product.&amp;lt;ref name=&quot;VR_5.2&quot;&amp;gt;Van Rossum (2027), §5.2.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Other aspects of an assembly can also change during exposure&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;. The &lt;/del&gt;International Fire Engineering Guidelines include damaged service pipes and cable trays among conditions that can create openings. Integrity therefore depends on more than the initial appearance of the filled gap. The assessment concerns whether the intended boundary remains effective through the relevant event.&amp;lt;ref name=&quot;IFEG_1.6-6&quot;&amp;gt;Australian Building Codes Board et al. (2005), p. 1.6-6.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Other aspects of an assembly can also change during exposure&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;; the &lt;/ins&gt;International Fire Engineering Guidelines include damaged service pipes and cable trays among conditions that can create openings. Integrity therefore depends on more than the initial appearance of the filled gap. The assessment concerns whether the intended boundary remains effective through the relevant event.&amp;lt;ref name=&quot;IFEG_1.6-6&quot;&amp;gt;Australian Building Codes Board et al. (2005), p. 1.6-6.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Product evidence and installation details consequently answer different but connected questions. Testing supports a stated construction under defined conditions. Installation establishes whether that construction has been reproduced in the building. New Zealand&amp;#039;s 2025 verification method explicitly connects construction detailing to the developed design.&amp;lt;ref name=&amp;quot;M_4-209_4-210&amp;quot;&amp;gt;Milke (2002), pp. 4-209–4-210.&amp;lt;/ref&amp;gt;&amp;lt;ref name=&amp;quot;CVM_13&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Product evidence and installation details consequently answer different but connected questions. Testing supports a stated construction under defined conditions. Installation establishes whether that construction has been reproduced in the building. New Zealand&amp;#039;s 2025 verification method explicitly connects construction detailing to the developed design.&amp;lt;ref name=&amp;quot;M_4-209_4-210&amp;quot;&amp;gt;Milke (2002), pp. 4-209–4-210.&amp;lt;/ref&amp;gt;&amp;lt;ref name=&amp;quot;CVM_13&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l29&quot;&gt;Line 29:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 29:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Distinction from dampers and cavity barriers ==&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Distinction from dampers and cavity barriers ==&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;A [[Fire damper]] closes the passage inside a ventilation duct or opening&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;. A &lt;/del&gt;penetration seal addresses the path around that assembly where it crosses a wall or floor. Those paths can exist at the same location but require different protective functions. Closing one does not demonstrate that the other has been protected.&amp;lt;ref name=&quot;N_F-19&quot; /&amp;gt;&amp;lt;ref name=&quot;N_F-44&quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;A [[Fire damper]] closes the passage inside a ventilation duct or opening&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;, and a &lt;/ins&gt;penetration seal addresses the path around that assembly where it crosses a wall or floor. Those paths can exist at the same location but require different protective functions. Closing one does not demonstrate that the other has been protected.&amp;lt;ref name=&quot;N_F-19&quot; /&amp;gt;&amp;lt;ref name=&quot;N_F-44&quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[[File:fse-firestopping-v2.svg|thumb|upright=1.5|alt=Damper stops airflow inside duct while firestop seals the gap between duct and wall.|Damper and firestop perform complementary functions. Based on Iqbal and Salley (2004), p. F-19 and p. F-44.]]&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[[File:fse-firestopping-v2.svg|thumb|upright=1.5|alt=Damper stops airflow inside duct while firestop seals the gap between duct and wall.|Damper and firestop perform complementary functions. Based on Iqbal and Salley (2004), p. F-19 and p. F-44.]]&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;A [[Cavity barrier]] restricts spread within a concealed space or closes an opening within that space. C/VM2 defines it separately from the fire stop used at a separation&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;. The &lt;/del&gt;distinction concerns the route and location being protected. It prevents every concealed barrier or service seal from being treated as the same type of construction.&amp;lt;ref name=&quot;CVM_62&quot; /&amp;gt;&amp;lt;ref name=&quot;CVM_65&quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;A [[Cavity barrier]] restricts spread within a concealed space or closes an opening within that space. C/VM2 defines it separately from the fire stop used at a separation&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;, and the &lt;/ins&gt;distinction concerns the route and location being protected. It prevents every concealed barrier or service seal from being treated as the same type of construction.&amp;lt;ref name=&quot;CVM_62&quot; /&amp;gt;&amp;lt;ref name=&quot;CVM_65&quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Building joints are another distinct application. Iqbal and Salley&#039;s list of standards separates through-penetration firestop tests from tests for building joint systems&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;. A &lt;/del&gt;joint and a service penetration therefore have different evidential descriptions in that source. Their performance cannot be established by ignoring what the cited test actually evaluates.&amp;lt;ref name=&quot;N_C-15&quot;&amp;gt;Iqbal and Salley (2004), p. C-15.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Building joints are another distinct application. Iqbal and Salley&#039;s list of standards separates through-penetration firestop tests from tests for building joint systems&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;; a &lt;/ins&gt;joint and a service penetration therefore have different evidential descriptions in that source. Their performance cannot be established by ignoring what the cited test actually evaluates.&amp;lt;ref name=&quot;N_C-15&quot;&amp;gt;Iqbal and Salley (2004), p. C-15.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Terminology can also vary between technical contexts&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;. The &lt;/del&gt;NUREG glossary uses fire stop for a feature restricting propagation along cables or towards nearby combustible material. It separately defines penetration seals at rated boundaries. A cable-tray fire stop described in an incident report is consequently not automatically a wall-penetration seal of the same design.&amp;lt;ref name=&quot;N_F-29&quot; /&amp;gt;&amp;lt;ref name=&quot;N_F-44&quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Terminology can also vary between technical contexts&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;, and the &lt;/ins&gt;NUREG glossary uses fire stop for a feature restricting propagation along cables or towards nearby combustible material. It separately defines penetration seals at rated boundaries. A cable-tray fire stop described in an incident report is consequently not automatically a wall-penetration seal of the same design.&amp;lt;ref name=&quot;N_F-29&quot; /&amp;gt;&amp;lt;ref name=&quot;N_F-44&quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Tests and the limits of a classification ==&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Tests and the limits of a classification ==&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l43&quot;&gt;Line 43:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 43:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;A [[Fire resistance test]] evaluates specified functions under a defined exposure. The assembly, measurement criteria and duration belong together. A generic material description does not provide these details. The evidence therefore needs to identify the tested protective arrangement and the function claimed from it.&amp;lt;ref name=&amp;quot;KH_1-155&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;M_4-209_4-210&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;A [[Fire resistance test]] evaluates specified functions under a defined exposure. The assembly, measurement criteria and duration belong together. A generic material description does not provide these details. The evidence therefore needs to identify the tested protective arrangement and the function claimed from it.&amp;lt;ref name=&amp;quot;KH_1-155&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;M_4-209_4-210&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The 2004 NUREG report identifies ASTM E814 and UL 1479 as through-penetration firestop test standards&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;. It &lt;/del&gt;separately lists UL 2079 for building joint systems. These references establish which test subjects the report distinguishes. The list is not a substitute for the full standards or a current classification of an installed product.&amp;lt;ref name=&quot;N_C-15&quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The 2004 NUREG report identifies ASTM E814 and UL 1479 as through-penetration firestop test standards&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;, and it &lt;/ins&gt;separately lists UL 2079 for building joint systems. These references establish which test subjects the report distinguishes. The list is not a substitute for the full standards or a current classification of an installed product.&amp;lt;ref name=&quot;N_C-15&quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The source&#039;s regulatory setting also remains relevant. NUREG-1805 supports the United States nuclear fire-protection inspection programme, while C/VM2 provides a New Zealand verification method&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;. Their &lt;/del&gt;definitions and examples can explain physical functions without becoming universal installation rules. Any stated requirement retains the country, document and edition from which it comes.&amp;lt;ref name=&quot;N_F-44&quot; /&amp;gt;&amp;lt;ref name=&quot;CVM_13&quot; /&amp;gt;&amp;lt;ref name=&quot;CVM_65&quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The source&#039;s regulatory setting also remains relevant. NUREG-1805 supports the United States nuclear fire-protection inspection programme, while C/VM2 provides a New Zealand verification method&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;; their &lt;/ins&gt;definitions and examples can explain physical functions without becoming universal installation rules. Any stated requirement retains the country, document and edition from which it comes.&amp;lt;ref name=&quot;N_F-44&quot; /&amp;gt;&amp;lt;ref name=&quot;CVM_13&quot; /&amp;gt;&amp;lt;ref name=&quot;CVM_65&quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Smoke performance requires its own interpretation. Klote explains that pressure differences can drive smoke through leakage paths around penetrations and construction joints. A fire-endurance description does not quantify that flow by itself. The credited smoke-separation function therefore needs evidence about the relevant path and operating conditions.&amp;lt;ref name=&amp;quot;Kl_4-277_4-278&amp;quot;&amp;gt;Klote (2002), pp. 4-277–4-278.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Smoke performance requires its own interpretation. Klote explains that pressure differences can drive smoke through leakage paths around penetrations and construction joints. A fire-endurance description does not quantify that flow by itself. The credited smoke-separation function therefore needs evidence about the relevant path and operating conditions.&amp;lt;ref name=&amp;quot;Kl_4-277_4-278&amp;quot;&amp;gt;Klote (2002), pp. 4-277–4-278.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l57&quot;&gt;Line 57:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 57:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The authors state that it was unclear whether the vertical fire stop delayed propagation. That uncertainty matters: continued spread does not establish the size of any delay, and no delay should be invented from the account. The observed horizontal outcome likewise does not prove that every horizontal arrangement performs the same way. The evidence concerns the reported installation and incident.&amp;lt;ref name=&amp;quot;N_H-23&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The authors state that it was unclear whether the vertical fire stop delayed propagation. That uncertainty matters: continued spread does not establish the size of any delay, and no delay should be invented from the account. The observed horizontal outcome likewise does not prove that every horizontal arrangement performs the same way. The evidence concerns the reported installation and incident.&amp;lt;ref name=&amp;quot;N_H-23&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The example also needs the correct object of comparison&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;. These &lt;/del&gt;were cable-tray propagation features, not a controlled comparison of every wall and floor penetration system. The NUREG terminology distinguishes those uses. Treating the incident as a universal product test would extend the observation beyond what the report establishes.&amp;lt;ref name=&quot;N_H-23&quot; /&amp;gt;&amp;lt;ref name=&quot;N_F-29&quot; /&amp;gt;&amp;lt;ref name=&quot;N_F-44&quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The example also needs the correct object of comparison&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;: these &lt;/ins&gt;were cable-tray propagation features, not a controlled comparison of every wall and floor penetration system. The NUREG terminology distinguishes those uses. Treating the incident as a universal product test would extend the observation beyond what the report establishes.&amp;lt;ref name=&quot;N_H-23&quot; /&amp;gt;&amp;lt;ref name=&quot;N_F-29&quot; /&amp;gt;&amp;lt;ref name=&quot;N_F-44&quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Configuration nevertheless has direct relevance to construction evidence. C/VM2&amp;#039;s separate requirement for appropriate orientation and separating element identifies the same need to retain application conditions. A result or observation becomes less informative when those conditions are removed. The evidence describes an arrangement, rather than the word firestop in isolation.&amp;lt;ref name=&amp;quot;CVM_13&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;N_H-23&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Configuration nevertheless has direct relevance to construction evidence. C/VM2&amp;#039;s separate requirement for appropriate orientation and separating element identifies the same need to retain application conditions. A result or observation becomes less informative when those conditions are removed. The evidence describes an arrangement, rather than the word firestop in isolation.&amp;lt;ref name=&amp;quot;CVM_13&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;N_H-23&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l67&quot;&gt;Line 67:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 67:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Later modifications can change the original arrangement. New services, altered openings or repairs can affect boundaries whose fire-safety role is not obvious locally. The guidelines note that passive components are liable to be overlooked during such work. Continued identification connects the alteration to the separation it crosses.&amp;lt;ref name=&amp;quot;IFEG_1.6-9&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Later modifications can change the original arrangement. New services, altered openings or repairs can affect boundaries whose fire-safety role is not obvious locally. The guidelines note that passive components are liable to be overlooked during such work. Continued identification connects the alteration to the separation it crosses.&amp;lt;ref name=&amp;quot;IFEG_1.6-9&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Inspection and records preserve information about the resulting condition. The guidelines call for maintenance requirements to be documented and outcomes recorded&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;. They &lt;/del&gt;do not provide one universal seal recipe or inspection interval. The relevant product evidence and construction details remain necessary to assess the actual installed system.&amp;lt;ref name=&quot;IFEG_1.6-9&quot; /&amp;gt;&amp;lt;ref name=&quot;CVM_13&quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Inspection and records preserve information about the resulting condition. The guidelines call for maintenance requirements to be documented and outcomes recorded&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;, but they &lt;/ins&gt;do not provide one universal seal recipe or inspection interval. The relevant product evidence and construction details remain necessary to assess the actual installed system.&amp;lt;ref name=&quot;IFEG_1.6-9&quot; /&amp;gt;&amp;lt;ref name=&quot;CVM_13&quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== See also ==&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== See also ==&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;

&lt;!-- diff cache key firesb_pjbsiy42-wiki_:diff:1.41:old-2766:rev-2819:php=table --&gt;
&lt;/table&gt;</summary>
		<author><name>Emma</name></author>
	</entry>
	<entry>
		<id>https://fire-safety.academy/w/index.php?title=Firestopping&amp;diff=2766&amp;oldid=prev</id>
		<title>Emma: Revise Basic article against FSE writing guidelines: sourced explanations, examples and references (GPT-6)</title>
		<link rel="alternate" type="text/html" href="https://fire-safety.academy/w/index.php?title=Firestopping&amp;diff=2766&amp;oldid=prev"/>
		<updated>2026-11-02T18:14:32Z</updated>

		<summary type="html">&lt;p&gt;Revise Basic article against FSE writing guidelines: sourced explanations, examples and references (GPT-6)&lt;/p&gt;
&lt;a href=&quot;https://fire-safety.academy/w/index.php?title=Firestopping&amp;amp;diff=2766&amp;amp;oldid=970&quot;&gt;Show changes&lt;/a&gt;</summary>
		<author><name>Emma</name></author>
	</entry>
	<entry>
		<id>https://fire-safety.academy/w/index.php?title=Firestopping&amp;diff=970&amp;oldid=prev</id>
		<title>Sanne: Add diagrams fse-firestopping-v1.svg, fse-firestopping-v2.svg, fse-firestopping-v3.svg (level-1 visual plan)</title>
		<link rel="alternate" type="text/html" href="https://fire-safety.academy/w/index.php?title=Firestopping&amp;diff=970&amp;oldid=prev"/>
		<updated>2026-11-02T07:09:19Z</updated>

		<summary type="html">&lt;p&gt;Add diagrams fse-firestopping-v1.svg, fse-firestopping-v2.svg, fse-firestopping-v3.svg (level-1 visual plan)&lt;/p&gt;
&lt;table style=&quot;background-color: #fff; color: #202122;&quot; data-mw=&quot;interface&quot;&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;tr class=&quot;diff-title&quot; lang=&quot;en&quot;&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;← Older revision&lt;/td&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;Revision as of 08:09, 2 November 2026&lt;/td&gt;
				&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l2&quot;&gt;Line 2:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 2:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Firestopping addresses the paths created by cables, pipes, ducts, cable trays, joints and other services. A fire-resisting wall or floor can otherwise be bypassed through those openings. The seal, the service and the surrounding element must therefore be assessed as one assembly.&amp;lt;ref name=&amp;quot;CVM2-13&amp;quot;&amp;gt;Ministry of Business, Innovation and Employment (2025), p. 13.&amp;lt;/ref&amp;gt;&amp;lt;ref name=&amp;quot;IFEG-1.6-7&amp;quot;&amp;gt;Australian Building Codes Board et al. (2005), p. 1.6-7.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Firestopping addresses the paths created by cables, pipes, ducts, cable trays, joints and other services. A fire-resisting wall or floor can otherwise be bypassed through those openings. The seal, the service and the surrounding element must therefore be assessed as one assembly.&amp;lt;ref name=&amp;quot;CVM2-13&amp;quot;&amp;gt;Ministry of Business, Innovation and Employment (2025), p. 13.&amp;lt;/ref&amp;gt;&amp;lt;ref name=&amp;quot;IFEG-1.6-7&amp;quot;&amp;gt;Australian Building Codes Board et al. (2005), p. 1.6-7.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-deleted&quot;&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;[[File:fse-firestopping-v1.svg|thumb|upright=1.5|alt=Unsealed tray carrying flame and sealed penetration blocking it, with backing and contact shown.|Firestopping closes service paths through a fire separation. Based on Ministry of Business, Innovation and Employment (2025), p. 64.]]&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The seal is not a generic filler. Its rating, orientation, movement, adhesion and compatibility with the barrier and service affect performance. A product that works in one penetration arrangement may be unsuitable in another.&amp;lt;ref name=&amp;quot;CVM2-13&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;Beyler-Hirschler-1-110&amp;quot;&amp;gt;Beyler and Hirschler (2002), p. 1-110.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The seal is not a generic filler. Its rating, orientation, movement, adhesion and compatibility with the barrier and service affect performance. A product that works in one penetration arrangement may be unsuitable in another.&amp;lt;ref name=&amp;quot;CVM2-13&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;Beyler-Hirschler-1-110&amp;quot;&amp;gt;Beyler and Hirschler (2002), p. 1-110.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l38&quot;&gt;Line 38:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 39:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;A [[Fire damper]] closes the interior of a duct to resist heat and flame, while firestopping seals the region between the duct and the separating element. These functions are complementary and should not be treated as interchangeable. Both are needed for a complete duct penetration.&amp;lt;ref name=&amp;quot;NUREG-1805-F-19&amp;quot;&amp;gt;U.S. Nuclear Regulatory Commission (2005), p. F-19.&amp;lt;/ref&amp;gt;&amp;lt;ref name=&amp;quot;CVM2-13&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;A [[Fire damper]] closes the interior of a duct to resist heat and flame, while firestopping seals the region between the duct and the separating element. These functions are complementary and should not be treated as interchangeable. Both are needed for a complete duct penetration.&amp;lt;ref name=&amp;quot;NUREG-1805-F-19&amp;quot;&amp;gt;U.S. Nuclear Regulatory Commission (2005), p. F-19.&amp;lt;/ref&amp;gt;&amp;lt;ref name=&amp;quot;CVM2-13&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-deleted&quot;&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;[[File:fse-firestopping-v2.svg|thumb|upright=1.5|alt=Damper stops airflow inside duct while firestop seals the gap between duct and wall.|Damper and firestop perform complementary functions. Based on U.S. Nuclear Regulatory Commission (2005), p. F-19 and p. F-28.]]&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The damper must close against airflow and maintain its fire-resistance rating, while the seal must remain compatible with the barrier. A damper that closes but leaves a gap around the duct does not provide the intended separation. The reverse is also true: a good seal around an open duct leaves a pathway for smoke and flame.&amp;lt;ref name=&amp;quot;NUREG-1805-F-19&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;IFEG-1.6-7&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The damper must close against airflow and maintain its fire-resistance rating, while the seal must remain compatible with the barrier. A damper that closes but leaves a gap around the duct does not provide the intended separation. The reverse is also true: a good seal around an open duct leaves a pathway for smoke and flame.&amp;lt;ref name=&amp;quot;NUREG-1805-F-19&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;IFEG-1.6-7&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l58&quot;&gt;Line 58:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 60:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The Waterford 3 incident described in NUREG-1805 shows that a fire stop in a horizontal cable tray can be effective, while a stop in a vertical cable tray may be ineffective. The fire jumped over the vertical stop and continued to propagate. This demonstrates that orientation and arrangement can determine whether a firestop performs.&amp;lt;ref name=&amp;quot;NUREG-1805-H-23&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The Waterford 3 incident described in NUREG-1805 shows that a fire stop in a horizontal cable tray can be effective, while a stop in a vertical cable tray may be ineffective. The fire jumped over the vertical stop and continued to propagate. This demonstrates that orientation and arrangement can determine whether a firestop performs.&amp;lt;ref name=&amp;quot;NUREG-1805-H-23&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-deleted&quot;&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;[[File:fse-firestopping-v3.svg|thumb|upright=1.5|alt=Horizontal stop holds fire while vertical tray fire jumps the stop and continues.|Waterford incident shows different firestop outcomes by orientation. Based on U.S. Nuclear Regulatory Commission (2005), p. H-23.]]&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The same account says it was not clear whether the vertical stop delayed propagation. A firestop should therefore not be credited with an untested delay or with total containment. Incident evidence must distinguish what the stop actually achieved from what was intended.&amp;lt;ref name=&amp;quot;NUREG-1805-H-23&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The same account says it was not clear whether the vertical stop delayed propagation. A firestop should therefore not be credited with an untested delay or with total containment. Incident evidence must distinguish what the stop actually achieved from what was intended.&amp;lt;ref name=&amp;quot;NUREG-1805-H-23&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;

&lt;!-- diff cache key firesb_pjbsiy42-wiki_:diff:1.41:old-689:rev-970:php=table --&gt;
&lt;/table&gt;</summary>
		<author><name>Sanne</name></author>
	</entry>
	<entry>
		<id>https://fire-safety.academy/w/index.php?title=Firestopping&amp;diff=689&amp;oldid=prev</id>
		<title>Jan: New FSE wiki article: Firestopping (written by Kimi Code CLI)</title>
		<link rel="alternate" type="text/html" href="https://fire-safety.academy/w/index.php?title=Firestopping&amp;diff=689&amp;oldid=prev"/>
		<updated>2026-11-02T00:56:02Z</updated>

		<summary type="html">&lt;p&gt;New FSE wiki article: Firestopping (written by Kimi Code CLI)&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;&amp;#039;&amp;#039;&amp;#039;Firestopping&amp;#039;&amp;#039;&amp;#039; is a material or method of construction used to restrict fire spread within or through fire separations, with a fire resistance rating no less than that of the separation. It is mainly used to seal around service penetrations and narrow gaps between building elements. Its purpose is to preserve the integrity of the complete barrier.&amp;lt;ref name=&amp;quot;CVM2-64&amp;quot;&amp;gt;Ministry of Business, Innovation and Employment (2025), p. 64.&amp;lt;/ref&amp;gt;&amp;lt;ref name=&amp;quot;NUREG-1805-F-28&amp;quot;&amp;gt;U.S. Nuclear Regulatory Commission (2005), p. F-28.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Firestopping addresses the paths created by cables, pipes, ducts, cable trays, joints and other services. A fire-resisting wall or floor can otherwise be bypassed through those openings. The seal, the service and the surrounding element must therefore be assessed as one assembly.&amp;lt;ref name=&amp;quot;CVM2-13&amp;quot;&amp;gt;Ministry of Business, Innovation and Employment (2025), p. 13.&amp;lt;/ref&amp;gt;&amp;lt;ref name=&amp;quot;IFEG-1.6-7&amp;quot;&amp;gt;Australian Building Codes Board et al. (2005), p. 1.6-7.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
The seal is not a generic filler. Its rating, orientation, movement, adhesion and compatibility with the barrier and service affect performance. A product that works in one penetration arrangement may be unsuitable in another.&amp;lt;ref name=&amp;quot;CVM2-13&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;Beyler-Hirschler-1-110&amp;quot;&amp;gt;Beyler and Hirschler (2002), p. 1-110.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== Purpose in compartmentation ==&lt;br /&gt;
&lt;br /&gt;
[[Fire compartmentation]] depends on continuous separating elements, and firestopping closes the gaps that would otherwise allow fire and smoke through. It helps maintain integrity and can provide time for evacuation and intervention. A barrier is only as continuous as its weakest unsealed path.&amp;lt;ref name=&amp;quot;IFEG-1.6-7&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;CVM2-13&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
C/VM2 requires the fire stop to have a fire resistance rating no less than that of the fire separation. This prevents the penetration from becoming a deliberate weak point in the boundary. The rating must still be demonstrated using suitable evidence and installation.&amp;lt;ref name=&amp;quot;CVM2-64&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Firestopping also supports fire resistance by limiting temperature transfer around a service. Heat can travel through the seal or along a metal pipe or cable, so sealing the visible gap alone may not address every thermal path. The service and its supports should be included in the assessment.&amp;lt;ref name=&amp;quot;Rockett-Milke-1-29&amp;quot;&amp;gt;Rockett and Milke (2002), p. 1-29.&amp;lt;/ref&amp;gt;&amp;lt;ref name=&amp;quot;NUREG-1805-17-7&amp;quot;&amp;gt;U.S. Nuclear Regulatory Commission (2005), p. 17-7.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
The method must preserve the barrier during movement and fire. Building joints can move, services can expand or vibrate, and the surrounding construction can deform. A rigid seal that cracks or detaches can open a path even if it was effective when first installed.&amp;lt;ref name=&amp;quot;CVM2-13&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;Beyler-Hirschler-1-110&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== Intumescent materials and seals ==&lt;br /&gt;
&lt;br /&gt;
[[Intumescent material]] expands or develops a protective layer during heating and can close gaps or reduce heat transfer. It can protect the service and surrounding element, but its expansion, adhesion and continuity must remain appropriate to the penetration. The protective layer must not simply fall away or become permeable.&amp;lt;ref name=&amp;quot;Beyler-Hirschler-1-110&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;Beyler-Hirschler-1-114&amp;quot;&amp;gt;Beyler and Hirschler (2002), p. 1-114.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Other firestop materials can provide limited-combustible or noncombustible seals. Their performance depends on composition, installation and orientation rather than on noncombustibility alone. Shrinkage, cracking and poor contact can create a continuous leakage path.&amp;lt;ref name=&amp;quot;NUREG-1805-F-28&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;Kodur-Harmathy-1-155&amp;quot;&amp;gt;Kodur and Harmathy (2002), p. 1-155.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
A firestop can be a proprietary product or a method of construction, and the choice must suit the actual separating element. C/VM2 calls for appropriate proprietary products for the orientation and specific use. Product documentation and installation detail are therefore part of the firestop&amp;#039;s performance.&amp;lt;ref name=&amp;quot;CVM2-13&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Seals around moving services need to accommodate expected movement. A seal that is too rigid can crack, while one that is too soft can be displaced or eroded by heat and gases. The required movement and exposure should be evaluated rather than assuming one product fits every joint.&amp;lt;ref name=&amp;quot;Beyler-Hirschler-1-110&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;CVM2-13&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== Cavity barriers and concealed spaces ==&lt;br /&gt;
&lt;br /&gt;
A [[Cavity barrier]] closes openings within a concealed space against fire and smoke spread. Cavities can connect rooms and floors without an obvious door or grille, so they require the same attention as visible penetrations. Their location and continuity must be established.&amp;lt;ref name=&amp;quot;CVM2-49&amp;quot;&amp;gt;Ministry of Business, Innovation and Employment (2025), p. 49.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Concealed spaces can also contain combustible material and services, which changes the fire scenario. A cavity barrier may need to work with detection or suppression to control that risk. The barrier&amp;#039;s condition and the contents of the cavity must be assessed together.&amp;lt;ref name=&amp;quot;CVM2-49&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;IFEG-1.6-7&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Vertical shafts and service risers provide another route for fire and smoke. Firestops at each relevant level can limit that pathway, but failures and bypasses can occur. Cables and supports can also transfer heat and provide a direct route around an intended seal.&amp;lt;ref name=&amp;quot;IFEG-1.6-7&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;NUREG-1805-H-23&amp;quot;&amp;gt;U.S. Nuclear Regulatory Commission (2005), p. H-23.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Cavity details can change during refurbishment. New services and access openings create paths that were absent from the original design. Inspection should include hidden spaces rather than relying on the appearance of the main wall or floor.&amp;lt;ref name=&amp;quot;CVM2-13&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;NIST-1-6A-iii&amp;quot;&amp;gt;National Institute of Standards and Technology (2005), p. iii.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== Fire dampers and service openings ==&lt;br /&gt;
&lt;br /&gt;
A [[Fire damper]] closes the interior of a duct to resist heat and flame, while firestopping seals the region between the duct and the separating element. These functions are complementary and should not be treated as interchangeable. Both are needed for a complete duct penetration.&amp;lt;ref name=&amp;quot;NUREG-1805-F-19&amp;quot;&amp;gt;U.S. Nuclear Regulatory Commission (2005), p. F-19.&amp;lt;/ref&amp;gt;&amp;lt;ref name=&amp;quot;CVM2-13&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
The damper must close against airflow and maintain its fire-resistance rating, while the seal must remain compatible with the barrier. A damper that closes but leaves a gap around the duct does not provide the intended separation. The reverse is also true: a good seal around an open duct leaves a pathway for smoke and flame.&amp;lt;ref name=&amp;quot;NUREG-1805-F-19&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;IFEG-1.6-7&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Cable trays and pipes require similar coordination. Their supports and contents can transfer heat, and their arrangement can make sealing difficult around irregular shapes. The firestop must cover those shapes without leaving channels for gases or flames.&amp;lt;ref name=&amp;quot;NUREG-1805-F-28&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;Rockett-Milke-1-29&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Penetration seals must also accommodate service operation. Ducts and pipes can move, cables can be added later, and maintenance can disturb the seal. A firestop that cannot be restored after access will not provide continuing protection.&amp;lt;ref name=&amp;quot;CVM2-13&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;NIST-1-6A-iii&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== Testing and evidence ==&lt;br /&gt;
&lt;br /&gt;
The [[Fire resistance test]] for through-penetration fire stops assesses the seal under specified exposure. NUREG-1805 identifies ASTM E814 and UL 1479 as relevant standards for penetration seals. These methods provide evidence for the tested arrangement, not a universal rating for every penetration.&amp;lt;ref name=&amp;quot;NUREG-1805-F-28&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;NUREG-1805-F-44&amp;quot;&amp;gt;U.S. Nuclear Regulatory Commission (2005), p. F-44.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
IEEE 634 provides a cable-penetration fire-stop qualification test. This is particularly relevant to cable arrangements and illustrates that service type matters when selecting evidence. A seal tested for one service or geometry should not be transferred to another without assessment.&amp;lt;ref name=&amp;quot;NUREG-1805-C-12&amp;quot;&amp;gt;U.S. Nuclear Regulatory Commission (2005), p. C-12.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Fire resistance ratings for the seal and barrier must be compatible. C/VM2 requires the fire stop to have no lower rating than the separation, and construction detailing must match the design. That creates a clear link between the tested product, installation and intended assembly.&amp;lt;ref name=&amp;quot;CVM2-13&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;CVM2-64&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Test evidence should also match orientation and installation. A seal in a wall can experience different heat and movement from one in a floor, and a seal around a single pipe differs from one around a dense tray. Product selection should use the closest relevant evidence and acknowledge any differences.&amp;lt;ref name=&amp;quot;CVM2-13&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;NUREG-1805-F-28&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== Failure and incident evidence ==&lt;br /&gt;
&lt;br /&gt;
The Waterford 3 incident described in NUREG-1805 shows that a fire stop in a horizontal cable tray can be effective, while a stop in a vertical cable tray may be ineffective. The fire jumped over the vertical stop and continued to propagate. This demonstrates that orientation and arrangement can determine whether a firestop performs.&amp;lt;ref name=&amp;quot;NUREG-1805-H-23&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
The same account says it was not clear whether the vertical stop delayed propagation. A firestop should therefore not be credited with an untested delay or with total containment. Incident evidence must distinguish what the stop actually achieved from what was intended.&amp;lt;ref name=&amp;quot;NUREG-1805-H-23&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Fire can also jump over a stop through deformation, nearby combustibles or other paths. A complete review must examine those alternatives rather than assuming that the presence of a seal closes the scenario. The full sequence helps explain why the barrier failed.&amp;lt;ref name=&amp;quot;NUREG-1805-H-23&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;IFEG-1.6-7&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
A firestop that remains in place can still transmit heat to adjacent fuel. Integrity and insulation are separate criteria, and the unexposed side must be assessed for ignition. An apparently intact seal is not proof that fire spread has been prevented.&amp;lt;ref name=&amp;quot;IFEG-1.6-7&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;Kanury-2-231&amp;quot;&amp;gt;Kanury (2002), pp. 2-231–2-232.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== Installation and maintenance ==&lt;br /&gt;
&lt;br /&gt;
Installation must reproduce the tested or designed detail. Gaps, poor contact, incorrect backing, unsuitable products and incomplete coverage can create leakage paths. The firestop must fit the actual service and the separating element rather than just the opening&amp;#039;s visible outline.&amp;lt;ref name=&amp;quot;CVM2-13&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;NUREG-1805-F-28&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Maintenance must preserve continuity. Seals can be displaced during service work, and new cables or pipes can be added without restoring them. Any alteration should trigger review and, where necessary, replacement with a compatible firestop.&amp;lt;ref name=&amp;quot;CVM2-13&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;NIST-1-6A-iii&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
The surrounding construction also changes over time. Moisture, movement, corrosion and damage can alter the barrier and the seal&amp;#039;s adhesion. A seal that was appropriate at installation may no longer maintain the intended rating or integrity.&amp;lt;ref name=&amp;quot;Beyler-Hirschler-1-110&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;Kodur-Harmathy-1-156&amp;quot;&amp;gt;Kodur and Harmathy (2002), p. 1-156.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Inspection should include concealed spaces and the unexposed side. A seal can look sound from one side while leaving a channel or damaged region on the other. Complete assessment requires access to the whole penetration where feasible.&amp;lt;ref name=&amp;quot;IFEG-1.6-7&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;NIST-1-6A-iii&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== Limits and common misunderstandings ==&lt;br /&gt;
&lt;br /&gt;
Firestopping is not ordinary sealant or decoration. It is a fire-resisting material or construction method with a rating at least equal to the fire separation. The claim requires appropriate evidence and installation, not merely a filled gap.&amp;lt;ref name=&amp;quot;CVM2-64&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;CVM2-13&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
A fire damper and a firestop are not the same. The damper closes the duct interior, while the firestop seals around the penetration. Treating one as a substitute for the other can leave an open pathway for heat, smoke and flame.&amp;lt;ref name=&amp;quot;NUREG-1805-F-19&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;CVM2-13&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
An intact-looking seal does not prove that fire spread is impossible. Heat can pass through it or along services, and other openings can bypass the barrier. Insulation and integrity must be assessed alongside the seal&amp;#039;s presence.&amp;lt;ref name=&amp;quot;IFEG-1.6-7&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;Rockett-Milke-1-29&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Finally, a firestop is not a guarantee of permanent containment. Orientation, installation, movement and incident conditions can defeat it. The Waterford example shows why actual performance and remaining uncertainty must be reported rather than assumed.&amp;lt;ref name=&amp;quot;NUREG-1805-H-23&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;CVM2-13&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
The selected product should be checked against the service&amp;#039;s shape and the barrier&amp;#039;s orientation. Irregular trays, dense cables and moving pipes create different sealing problems from a single circular penetration. A product&amp;#039;s fire test is meaningful only when the installed arrangement is comparable.&amp;lt;ref name=&amp;quot;CVM2-13&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;NUREG-1805-F-28&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Backing and contact are equally important. A rated material placed over an unsupported void or without contact to the surrounding construction can leave a continuous channel. The assessment should therefore inspect the whole seal, not only the material named in the specification.&amp;lt;ref name=&amp;quot;CVM2-13&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;Beyler-Hirschler-1-110&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Movement should be considered during both normal service and fire. Thermal expansion, vibration and structural deformation can crack or displace a seal, while heat can change its flexibility and adhesion. Those changes can turn an apparently complete installation into an open path.&amp;lt;ref name=&amp;quot;Beyler-Hirschler-1-110&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;Rockett-Milke-1-29&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Hidden voids require their own review. Cavity barriers can be bypassed through unsealed joints or by combustible contents and services that create new paths. Inspection should therefore include the full cavity and not only the visible face of the wall or floor.&amp;lt;ref name=&amp;quot;CVM2-49&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;IFEG-1.6-7&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
For service modifications, the firestop should be treated as part of the work scope. New cables or pipes can require a different seal, and access can destroy an earlier one. Reinstating a compatible seal is necessary to restore the barrier rather than merely closing the work area visually.&amp;lt;ref name=&amp;quot;CVM2-13&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;NIST-1-6A-iii&amp;quot;&amp;gt;National Institute of Standards and Technology (2005), p. iii.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Incident evidence should be read carefully. Waterford shows that a horizontal stop can work while a vertical one can be jumped, and the reason for failure is not always fully established. The report should state what was observed and what remains uncertain rather than assigning a universal success or failure rate.&amp;lt;ref name=&amp;quot;NUREG-1805-H-23&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
A final review should connect the seal&amp;#039;s rating with the actual exposure and acceptance criteria. Integrity, insulation and service movement each need appropriate evidence, and a rating for the material alone does not answer them. This makes firestopping a verifiable part of the complete fire separation.&amp;lt;ref name=&amp;quot;CVM2-64&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;Milke-4-209&amp;quot;&amp;gt;Milke (2002), p. 4-209.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
For final acceptance, the firestop should be reviewed as part of the complete opening rather than as an isolated product. The barrier, service, seal, backing and movement determine whether the intended rating is achieved. Each must match the evidence used for the application.&amp;lt;ref name=&amp;quot;CVM2-13&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;NUREG-1805-F-28&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
The assessment should also include the seal&amp;#039;s condition after movement and service work. A firestop that was correct at installation can become ineffective through cracking, displacement or added services. Maintaining the rating requires those changes to be identified and repaired with compatible materials and methods.&amp;lt;ref name=&amp;quot;CVM2-13&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;NIST-1-6A-iii&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
A final report should distinguish the firestop&amp;#039;s tested rating from observed field performance. It should identify what was verified, what was altered and which pathways remain. This makes firestopping a documented part of compartmentation rather than an assumed guarantee of containment.&amp;lt;ref name=&amp;quot;CVM2-64&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;NUREG-1805-H-23&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
The rating should finally be tied to the actual penetration and its installation. A firestop can have suitable material properties yet fail because of poor contact, an unsuitable backing or an altered service. Those details must be verified before the seal is credited with preserving the separation.&amp;lt;ref name=&amp;quot;CVM2-13&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;NUREG-1805-F-28&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
For final acceptance, integrity and insulation should be checked at both sides of the penetration and along the service itself. A seal that remains in place can still transmit enough heat to ignite adjacent material, so a visual check alone is insufficient. The complete thermal and structural path must satisfy the required criteria.&amp;lt;ref name=&amp;quot;IFEG-1.6-7&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;Rockett-Milke-1-29&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== See also ==&lt;br /&gt;
&lt;br /&gt;
* [[Cavity barrier]]&lt;br /&gt;
* [[Fire damper]]&lt;br /&gt;
* [[Fire resistance test]]&lt;br /&gt;
&lt;br /&gt;
== Notes ==&lt;br /&gt;
&lt;br /&gt;
&amp;lt;references /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== References ==&lt;br /&gt;
&lt;br /&gt;
* Australian Building Codes Board, National Research Council of Canada, International Code Council, &amp;amp; Department of Building and Housing New Zealand. (2005). &amp;#039;&amp;#039;International fire engineering guidelines&amp;#039;&amp;#039; (2005 ed.). Australian Building Codes Board.&lt;br /&gt;
* Beyler, C. L., &amp;amp; Hirschler, M. M. (2002). Thermal decomposition of polymers. In P. J. DiNenno (Ed.), &amp;#039;&amp;#039;SFPE handbook of fire protection engineering&amp;#039;&amp;#039; (3rd ed.). National Fire Protection Association.&lt;br /&gt;
* Kanury, A. M. (2002). Flaming ignition of solid fuels. In P. J. DiNenno (Ed.), &amp;#039;&amp;#039;SFPE handbook of fire protection engineering&amp;#039;&amp;#039; (3rd ed.). National Fire Protection Association.&lt;br /&gt;
* Kodur, V. K. R., &amp;amp; Harmathy, T. Z. (2002). Properties of building materials. In P. J. DiNenno (Ed.), &amp;#039;&amp;#039;SFPE handbook of fire protection engineering&amp;#039;&amp;#039; (3rd ed.). National Fire Protection Association.&lt;br /&gt;
* Ministry of Business, Innovation and Employment. (2025). &amp;#039;&amp;#039;C protection from fire: Verification method C/VM2&amp;#039;&amp;#039; (2nd ed.). New Zealand Government.&lt;br /&gt;
* National Institute of Standards and Technology. (2005). &amp;#039;&amp;#039;Passive fire protection&amp;#039;&amp;#039; (NIST NCSTAR 1-6A). U.S. Department of Commerce.&lt;br /&gt;
* Rockett, J. A., &amp;amp; Milke, J. A. (2002). Conduction of heat in solids. In P. J. DiNenno (Ed.), &amp;#039;&amp;#039;SFPE handbook of fire protection engineering&amp;#039;&amp;#039; (3rd ed.). National Fire Protection Association.&lt;br /&gt;
* U.S. Nuclear Regulatory Commission. (2005). &amp;#039;&amp;#039;Fire dynamics tools: Quantitative fire hazard analysis methods for the U.S. nuclear regulatory commission fire protection inspection program&amp;#039;&amp;#039; (NUREG-1805). Author.&lt;br /&gt;
&lt;br /&gt;
[[Category:Passive Fire Protection]]&lt;/div&gt;</summary>
		<author><name>Jan</name></author>
	</entry>
</feed>