<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://fire-safety.academy/w/index.php?action=history&amp;feed=atom&amp;title=Decontamination</id>
	<title>Decontamination - Revision history</title>
	<link rel="self" type="application/atom+xml" href="https://fire-safety.academy/w/index.php?action=history&amp;feed=atom&amp;title=Decontamination"/>
	<link rel="alternate" type="text/html" href="https://fire-safety.academy/w/index.php?title=Decontamination&amp;action=history"/>
	<updated>2026-11-21T21:45:48Z</updated>
	<subtitle>Revision history for this page on the wiki</subtitle>
	<generator>MediaWiki 1.43.11</generator>
	<entry>
		<id>https://fire-safety.academy/w/index.php?title=Decontamination&amp;diff=9340&amp;oldid=prev</id>
		<title>Peter: Wiki review: corrected 1 error: content (Claude Opus 5.5)</title>
		<link rel="alternate" type="text/html" href="https://fire-safety.academy/w/index.php?title=Decontamination&amp;diff=9340&amp;oldid=prev"/>
		<updated>2026-11-15T23:43:20Z</updated>

		<summary type="html">&lt;p&gt;Wiki review: corrected 1 error: content (Claude Opus 5.5)&lt;/p&gt;
&lt;table style=&quot;background-color: #fff; color: #202122;&quot; data-mw=&quot;interface&quot;&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;tr class=&quot;diff-title&quot; lang=&quot;en&quot;&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;← Older revision&lt;/td&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;Revision as of 00:43, 16 November 2026&lt;/td&gt;
				&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l23&quot;&gt;Line 23:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 23:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[[File:fse-decontamination-v3.svg|thumb|upright=1.5|alt=Four numbered selection steps leading to a choice among six decontamination options|Steps for selecting a decontamination process and the possible decontamination options.]]&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[[File:fse-decontamination-v3.svg|thumb|upright=1.5|alt=Four numbered selection steps leading to a choice among six decontamination options|Steps for selecting a decontamination process and the possible decontamination options.]]&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The third step is to seek advice. Immediate decontamination guidance is found in the first-aid sections of the numbered guide pages of the Emergency Response Guidebook.&amp;lt;ref name=&quot;Wr-13-141&quot; /&amp;gt; Other immediate sources are the pocket guide to chemical hazards of the National Institute &lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;of &lt;/del&gt;Occupational Safety and Health (NIOSH) and local planning documents.&amp;lt;ref name=&quot;Wr-13-141&quot; /&amp;gt; Follow-up guidance can come from poison control centres, from the shipper or manufacturer through CHEMTREC, and from the Agency for Toxic Substances and Disease Registry.&amp;lt;ref name=&quot;Wr-13-141&quot; /&amp;gt; The fourth step is to identify how clothing and equipment that cannot be decontaminated will be isolated, secured and disposed of.&amp;lt;ref name=&quot;Wr-13-141&quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The third step is to seek advice. Immediate decontamination guidance is found in the first-aid sections of the numbered guide pages of the Emergency Response Guidebook.&amp;lt;ref name=&quot;Wr-13-141&quot; /&amp;gt; Other immediate sources are the pocket guide to chemical hazards of the National Institute &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;for &lt;/ins&gt;Occupational Safety and Health (NIOSH) and local planning documents.&amp;lt;ref name=&quot;Wr-13-141&quot; /&amp;gt; Follow-up guidance can come from poison control centres, from the shipper or manufacturer through CHEMTREC, and from the Agency for Toxic Substances and Disease Registry.&amp;lt;ref name=&quot;Wr-13-141&quot; /&amp;gt; The fourth step is to identify how clothing and equipment that cannot be decontaminated will be isolated, secured and disposed of.&amp;lt;ref name=&quot;Wr-13-141&quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Water was the usual medium in the FDNY procedure, but not always. Members showered for a period set by the substance involved, except where the substance is made more active by water.&amp;lt;ref name=&amp;quot;LV-A-5.3.2&amp;quot;&amp;gt;Lawson and Vettori (2005), Appendix A, FDNY hazardous materials plan, §5.3.2.&amp;lt;/ref&amp;gt; The steps were designed for worst-case incidents, and the decision to apply all or part of them was to rest on a field analysis of the hazards and risks.&amp;lt;ref name=&amp;quot;LV-A-5.3.2&amp;quot; /&amp;gt; The toxicological and reactivity information that decided which techniques applied came from the Hazardous Materials Unit and the city departments of health and environmental protection.&amp;lt;ref name=&amp;quot;LV-A-5.3.2&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Water was the usual medium in the FDNY procedure, but not always. Members showered for a period set by the substance involved, except where the substance is made more active by water.&amp;lt;ref name=&amp;quot;LV-A-5.3.2&amp;quot;&amp;gt;Lawson and Vettori (2005), Appendix A, FDNY hazardous materials plan, §5.3.2.&amp;lt;/ref&amp;gt; The steps were designed for worst-case incidents, and the decision to apply all or part of them was to rest on a field analysis of the hazards and risks.&amp;lt;ref name=&amp;quot;LV-A-5.3.2&amp;quot; /&amp;gt; The toxicological and reactivity information that decided which techniques applied came from the Hazardous Materials Unit and the city departments of health and environmental protection.&amp;lt;ref name=&amp;quot;LV-A-5.3.2&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;

&lt;!-- diff cache key firesb_pjbsiy42-wiki_:diff:1.41:old-9088:rev-9340:php=table --&gt;
&lt;/table&gt;</summary>
		<author><name>Peter</name></author>
	</entry>
	<entry>
		<id>https://fire-safety.academy/w/index.php?title=Decontamination&amp;diff=9088&amp;oldid=prev</id>
		<title>Linda: Add SVG figures fse-decontamination-v1.svg, fse-decontamination-v2.svg, fse-decontamination-v3.svg, fse-decontamination-v4.svg (list-8 visual plan)</title>
		<link rel="alternate" type="text/html" href="https://fire-safety.academy/w/index.php?title=Decontamination&amp;diff=9088&amp;oldid=prev"/>
		<updated>2026-11-14T17:55:20Z</updated>

		<summary type="html">&lt;p&gt;Add SVG figures fse-decontamination-v1.svg, fse-decontamination-v2.svg, fse-decontamination-v3.svg, fse-decontamination-v4.svg (list-8 visual plan)&lt;/p&gt;
&lt;table style=&quot;background-color: #fff; color: #202122;&quot; data-mw=&quot;interface&quot;&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;tr class=&quot;diff-title&quot; lang=&quot;en&quot;&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;← Older revision&lt;/td&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;Revision as of 18:55, 14 November 2026&lt;/td&gt;
				&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l21&quot;&gt;Line 21:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 21:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Wright lists four steps for selecting a process. The first is to identify what needs decontamination: injured persons, response personnel, protective equipment, other equipment and emergency-care facilities.&amp;lt;ref name=&amp;quot;Wr-13-140&amp;quot; /&amp;gt; The second is to determine the contaminant and the type and amount of contamination.&amp;lt;ref name=&amp;quot;Wr-13-141&amp;quot; /&amp;gt; Relevant questions are whether the material is organic or inorganic, solid, liquid or gas, a skin or inhalation hazard, and local or systemic in its effect.&amp;lt;ref name=&amp;quot;Wr-13-141&amp;quot; /&amp;gt; Responders also judge whether it is life threatening, injurious or irritating, and whether physical trauma is involved.&amp;lt;ref name=&amp;quot;Wr-13-141&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Wright lists four steps for selecting a process. The first is to identify what needs decontamination: injured persons, response personnel, protective equipment, other equipment and emergency-care facilities.&amp;lt;ref name=&amp;quot;Wr-13-140&amp;quot; /&amp;gt; The second is to determine the contaminant and the type and amount of contamination.&amp;lt;ref name=&amp;quot;Wr-13-141&amp;quot; /&amp;gt; Relevant questions are whether the material is organic or inorganic, solid, liquid or gas, a skin or inhalation hazard, and local or systemic in its effect.&amp;lt;ref name=&amp;quot;Wr-13-141&amp;quot; /&amp;gt; Responders also judge whether it is life threatening, injurious or irritating, and whether physical trauma is involved.&amp;lt;ref name=&amp;quot;Wr-13-141&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-deleted&quot;&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;[[File:fse-decontamination-v3.svg|thumb|upright=1.5|alt=Four numbered selection steps leading to a choice among six decontamination options|Steps for selecting a decontamination process and the possible decontamination options.]]&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The third step is to seek advice. Immediate decontamination guidance is found in the first-aid sections of the numbered guide pages of the Emergency Response Guidebook.&amp;lt;ref name=&amp;quot;Wr-13-141&amp;quot; /&amp;gt; Other immediate sources are the pocket guide to chemical hazards of the National Institute of Occupational Safety and Health (NIOSH) and local planning documents.&amp;lt;ref name=&amp;quot;Wr-13-141&amp;quot; /&amp;gt; Follow-up guidance can come from poison control centres, from the shipper or manufacturer through CHEMTREC, and from the Agency for Toxic Substances and Disease Registry.&amp;lt;ref name=&amp;quot;Wr-13-141&amp;quot; /&amp;gt; The fourth step is to identify how clothing and equipment that cannot be decontaminated will be isolated, secured and disposed of.&amp;lt;ref name=&amp;quot;Wr-13-141&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The third step is to seek advice. Immediate decontamination guidance is found in the first-aid sections of the numbered guide pages of the Emergency Response Guidebook.&amp;lt;ref name=&amp;quot;Wr-13-141&amp;quot; /&amp;gt; Other immediate sources are the pocket guide to chemical hazards of the National Institute of Occupational Safety and Health (NIOSH) and local planning documents.&amp;lt;ref name=&amp;quot;Wr-13-141&amp;quot; /&amp;gt; Follow-up guidance can come from poison control centres, from the shipper or manufacturer through CHEMTREC, and from the Agency for Toxic Substances and Disease Registry.&amp;lt;ref name=&amp;quot;Wr-13-141&amp;quot; /&amp;gt; The fourth step is to identify how clothing and equipment that cannot be decontaminated will be isolated, secured and disposed of.&amp;lt;ref name=&amp;quot;Wr-13-141&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l28&quot;&gt;Line 28:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 29:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== The decontamination corridor ==&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== The decontamination corridor ==&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Decontamination takes place in the warm zone, the area between the hot zone around the release and the cold zone with the command post.&amp;lt;ref name=&amp;quot;Wr-13-142&amp;quot; /&amp;gt; Wright&amp;#039;s diagram of control zones shows a decontamination corridor crossing the warm zone, with access control points on the hot line and on the contamination control line.&amp;lt;ref name=&amp;quot;Wr-13-143&amp;quot; /&amp;gt; The FDNY plan called this zone the contamination reduction area and stated that all decontamination activities occur there.&amp;lt;ref name=&amp;quot;LV-A-5.2.2&amp;quot;&amp;gt;Lawson and Vettori (2005), Appendix A, FDNY hazardous materials plan, §5.2.2.&amp;lt;/ref&amp;gt; Its purpose is to prevent or reduce the transfer of contaminants picked up by personnel or equipment returning from the exclusion area, the plan&amp;#039;s term for the hot zone.&amp;lt;ref name=&amp;quot;LV-A-5.2.2&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Decontamination takes place in the warm zone, the area between the hot zone around the release and the cold zone with the command post.&amp;lt;ref name=&amp;quot;Wr-13-142&amp;quot; /&amp;gt; Wright&amp;#039;s diagram of control zones shows a decontamination corridor crossing the warm zone, with access control points on the hot line and on the contamination control line.&amp;lt;ref name=&amp;quot;Wr-13-143&amp;quot; /&amp;gt; The FDNY plan called this zone the contamination reduction area and stated that all decontamination activities occur there.&amp;lt;ref name=&amp;quot;LV-A-5.2.2&amp;quot;&amp;gt;Lawson and Vettori (2005), Appendix A, FDNY hazardous materials plan, §5.2.2.&amp;lt;/ref&amp;gt; Its purpose is to prevent or reduce the transfer of contaminants picked up by personnel or equipment returning from the exclusion area, the plan&amp;#039;s term for the hot zone.&amp;lt;ref name=&amp;quot;LV-A-5.2.2&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-deleted&quot;&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;[[File:fse-decontamination-v1.svg|thumb|upright=1.5|alt=Plan of hot, warm and cold zones with a decontamination corridor crossing the warm zone from the hot line to the contamination control line|Position of the decontamination corridor in the warm zone (schematic, not to scale).]]&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Two lines bound the corridor. The hot line separates the exclusion area from the contamination reduction area, and a decontamination station for personnel or equipment is set up close to it.&amp;lt;ref name=&amp;quot;LV-A-5.2.2&amp;quot; /&amp;gt; The contamination control line separates the possibly contaminated area from the clean zone. Leaving the contamination reduction area for the clean area requires removal of suspected or known contaminated clothing and equipment.&amp;lt;ref name=&amp;quot;LV-A-5.2.2&amp;quot; /&amp;gt; Unless otherwise demonstrated, everything leaving the exclusion area should be considered contaminated.&amp;lt;ref name=&amp;quot;LV-A-5.2.1&amp;quot;&amp;gt;Lawson and Vettori (2005), Appendix A, FDNY hazardous materials plan, §5.2.1.&amp;lt;/ref&amp;gt; Potentially contaminated clothing and equipment are not permitted in the support area, where normal fire-fighting clothing is worn.&amp;lt;ref name=&amp;quot;LV-A-5.2.3&amp;quot;&amp;gt;Lawson and Vettori (2005), Appendix A, FDNY hazardous materials plan, §5.2.3.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Two lines bound the corridor. The hot line separates the exclusion area from the contamination reduction area, and a decontamination station for personnel or equipment is set up close to it.&amp;lt;ref name=&amp;quot;LV-A-5.2.2&amp;quot; /&amp;gt; The contamination control line separates the possibly contaminated area from the clean zone. Leaving the contamination reduction area for the clean area requires removal of suspected or known contaminated clothing and equipment.&amp;lt;ref name=&amp;quot;LV-A-5.2.2&amp;quot; /&amp;gt; Unless otherwise demonstrated, everything leaving the exclusion area should be considered contaminated.&amp;lt;ref name=&amp;quot;LV-A-5.2.1&amp;quot;&amp;gt;Lawson and Vettori (2005), Appendix A, FDNY hazardous materials plan, §5.2.1.&amp;lt;/ref&amp;gt; Potentially contaminated clothing and equipment are not permitted in the support area, where normal fire-fighting clothing is worn.&amp;lt;ref name=&amp;quot;LV-A-5.2.3&amp;quot;&amp;gt;Lawson and Vettori (2005), Appendix A, FDNY hazardous materials plan, §5.2.3.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l39&quot;&gt;Line 39:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 41:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The procedure had nine steps. An entry point was marked to guide contaminated personnel into the area, and protective clothing was removed and isolated in sealed plastic bags placed in recovery drums.&amp;lt;ref name=&amp;quot;LV-A-5.3.2&amp;quot; /&amp;gt; Members then entered the rear of the unit under the supervision of emergency medical service (EMS) personnel, removed personal effects and work clothing, and showered.&amp;lt;ref name=&amp;quot;LV-A-5.3.2&amp;quot; /&amp;gt; After showering they received towels and clothing and left the unit.&amp;lt;ref name=&amp;quot;LV-A-5.3.2&amp;quot; /&amp;gt; EMS personnel then took a medical history, checked vital signs and followed up complaints, usually in a medical vehicle on the clean side, and transported members who needed further care.&amp;lt;ref name=&amp;quot;LV-A-5.3.2&amp;quot; /&amp;gt; Finally, the unit was disconnected, and the Department of Environmental Protection analysed the shower waste water.&amp;lt;ref name=&amp;quot;LV-A-5.3.2&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The procedure had nine steps. An entry point was marked to guide contaminated personnel into the area, and protective clothing was removed and isolated in sealed plastic bags placed in recovery drums.&amp;lt;ref name=&amp;quot;LV-A-5.3.2&amp;quot; /&amp;gt; Members then entered the rear of the unit under the supervision of emergency medical service (EMS) personnel, removed personal effects and work clothing, and showered.&amp;lt;ref name=&amp;quot;LV-A-5.3.2&amp;quot; /&amp;gt; After showering they received towels and clothing and left the unit.&amp;lt;ref name=&amp;quot;LV-A-5.3.2&amp;quot; /&amp;gt; EMS personnel then took a medical history, checked vital signs and followed up complaints, usually in a medical vehicle on the clean side, and transported members who needed further care.&amp;lt;ref name=&amp;quot;LV-A-5.3.2&amp;quot; /&amp;gt; Finally, the unit was disconnected, and the Department of Environmental Protection analysed the shower waste water.&amp;lt;ref name=&amp;quot;LV-A-5.3.2&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-deleted&quot;&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;[[File:fse-decontamination-v2.svg|thumb|upright=1.5|alt=Flowchart of nine numbered steps from marked entry point through clothing removal, shower and medical check to analysis of shower water|Personnel decontamination procedure of the Fire Department of the City of New York, 1994 (worst-case sequence).]]&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The plan also tracked people and equipment. The Safety Operating Battalion Chief normally confirmed that all exposed members took part in the decontamination procedure; if that officer did not attend, the Special Operations Decon Officer performed this function. The Safety Chief recorded members&amp;#039; names and units with a description of the procedures used.&amp;lt;ref name=&amp;quot;LV-A-6.1&amp;quot;&amp;gt;Lawson and Vettori (2005), Appendix A, FDNY hazardous materials plan, §6.1.&amp;lt;/ref&amp;gt; Apparatus, tools, clothing and personal items stayed at the site until a member of the Special Operations Command had decided what needed decontamination.&amp;lt;ref name=&amp;quot;LV-A-5.3.3&amp;quot;&amp;gt;Lawson and Vettori (2005), Appendix A, FDNY hazardous materials plan, §5.3.3.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The plan also tracked people and equipment. The Safety Operating Battalion Chief normally confirmed that all exposed members took part in the decontamination procedure; if that officer did not attend, the Special Operations Decon Officer performed this function. The Safety Chief recorded members&amp;#039; names and units with a description of the procedures used.&amp;lt;ref name=&amp;quot;LV-A-6.1&amp;quot;&amp;gt;Lawson and Vettori (2005), Appendix A, FDNY hazardous materials plan, §6.1.&amp;lt;/ref&amp;gt; Apparatus, tools, clothing and personal items stayed at the site until a member of the Special Operations Command had decided what needed decontamination.&amp;lt;ref name=&amp;quot;LV-A-5.3.3&amp;quot;&amp;gt;Lawson and Vettori (2005), Appendix A, FDNY hazardous materials plan, §5.3.3.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l50&quot;&gt;Line 50:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 53:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Fire stations need facilities for the same purpose. Acomb and LeBoeuf assume that station personnel, whether they provide [[fire-based emergency medical services|emergency medical care]] or hazardous materials response, will at some time meet a contamination problem requiring complete clothing removal.&amp;lt;ref name=&amp;quot;AL-12-239&amp;quot;&amp;gt;Acomb and LeBoeuf (2008), p. 12-239.&amp;lt;/ref&amp;gt; A decontamination room or space must then let personnel remove their outer clothing and clean their skin without contaminating the rest of the station.&amp;lt;ref name=&amp;quot;AL-12-239&amp;quot; /&amp;gt; Its equipment includes foot-activated hampers, motion- or foot-operated wash basins, automatic showers and doors, and spare clothes; a direct exterior entrance keeps contamination from spreading.&amp;lt;ref name=&amp;quot;AL-12-239&amp;quot; /&amp;gt; Laundry rooms with commercial machines clean turnout gear, because few commercial laundries will wash it.&amp;lt;ref name=&amp;quot;AL-12-240&amp;quot;&amp;gt;Acomb and LeBoeuf (2008), p. 12-240.&amp;lt;/ref&amp;gt; Under NFPA 1581, as described by Loflin, departments had to clean fire fighters&amp;#039; protective clothing at least every 6 months.&amp;lt;ref name=&amp;quot;Lof-12-115&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Fire stations need facilities for the same purpose. Acomb and LeBoeuf assume that station personnel, whether they provide [[fire-based emergency medical services|emergency medical care]] or hazardous materials response, will at some time meet a contamination problem requiring complete clothing removal.&amp;lt;ref name=&amp;quot;AL-12-239&amp;quot;&amp;gt;Acomb and LeBoeuf (2008), p. 12-239.&amp;lt;/ref&amp;gt; A decontamination room or space must then let personnel remove their outer clothing and clean their skin without contaminating the rest of the station.&amp;lt;ref name=&amp;quot;AL-12-239&amp;quot; /&amp;gt; Its equipment includes foot-activated hampers, motion- or foot-operated wash basins, automatic showers and doors, and spare clothes; a direct exterior entrance keeps contamination from spreading.&amp;lt;ref name=&amp;quot;AL-12-239&amp;quot; /&amp;gt; Laundry rooms with commercial machines clean turnout gear, because few commercial laundries will wash it.&amp;lt;ref name=&amp;quot;AL-12-240&amp;quot;&amp;gt;Acomb and LeBoeuf (2008), p. 12-240.&amp;lt;/ref&amp;gt; Under NFPA 1581, as described by Loflin, departments had to clean fire fighters&amp;#039; protective clothing at least every 6 months.&amp;lt;ref name=&amp;quot;Lof-12-115&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-deleted&quot;&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;[[File:fse-decontamination-v4.svg|thumb|upright=1.5|alt=Schematic floor plan of a station decontamination room with exterior entrance, hampers, showers, wash basins, clean clothing store and adjacent toilet|Schematic layout of a fire station decontamination room (illustrative, not to scale).]]&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Patients, hospitals and wider contamination ==&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Patients, hospitals and wider contamination ==&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;

&lt;!-- diff cache key firesb_pjbsiy42-wiki_:diff:1.41:old-5284:rev-9088:php=table --&gt;
&lt;/table&gt;</summary>
		<author><name>Linda</name></author>
	</entry>
	<entry>
		<id>https://fire-safety.academy/w/index.php?title=Decontamination&amp;diff=5284&amp;oldid=prev</id>
		<title>Linda: Add watermarked Fire Safety Academy illustration at the location specified in the visual plan</title>
		<link rel="alternate" type="text/html" href="https://fire-safety.academy/w/index.php?title=Decontamination&amp;diff=5284&amp;oldid=prev"/>
		<updated>2026-11-08T08:35:44Z</updated>

		<summary type="html">&lt;p&gt;Add watermarked Fire Safety Academy illustration at the location specified in the visual plan&lt;/p&gt;
&lt;table style=&quot;background-color: #fff; color: #202122;&quot; data-mw=&quot;interface&quot;&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;tr class=&quot;diff-title&quot; lang=&quot;en&quot;&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;← Older revision&lt;/td&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;Revision as of 09:35, 8 November 2026&lt;/td&gt;
				&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l35&quot;&gt;Line 35:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 35:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Personnel decontamination: the New York City procedure of 1994 ==&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Personnel decontamination: the New York City procedure of 1994 ==&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The FDNY plan, reproduced by the National Institute of Standards and Technology (NIST) in its report on the World Trade Center emergency response, sets out a complete personnel procedure. FDNY kept a Hazardous Materials Decontamination Unit consisting of a decontamination trailer and a support unit, and the police department had a similar unit as backup.&amp;lt;ref name=&amp;quot;LV-A-5.3.1&amp;quot;&amp;gt;Lawson and Vettori (2005), Appendix A, FDNY hazardous materials plan, §5.3.1.&amp;lt;/ref&amp;gt; Elsewhere in the United States, some departments acquired mobile decontamination trailers as part of domestic preparedness work.&amp;lt;ref name=&amp;quot;Den-12-64&amp;quot;&amp;gt;Denlinger (2008), p. 12-64.&amp;lt;/ref&amp;gt; The procedure applied to anything leaving the exclusion and contamination reduction areas, including personnel, protective equipment, monitoring equipment and clean-up equipment.&amp;lt;ref name=&amp;quot;LV-A-5.3&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The FDNY plan, reproduced by the National Institute of Standards and Technology (NIST) in its report on the World Trade Center emergency response, sets out a complete personnel procedure. FDNY kept a Hazardous Materials Decontamination Unit consisting of a decontamination trailer and a support unit, and the police department had a similar unit as backup.&amp;lt;ref name=&amp;quot;LV-A-5.3.1&amp;quot;&amp;gt;Lawson and Vettori (2005), Appendix A, FDNY hazardous materials plan, §5.3.1.&amp;lt;/ref&amp;gt; Elsewhere in the United States, some departments acquired mobile decontamination trailers as part of domestic preparedness work.&amp;lt;ref name=&amp;quot;Den-12-64&amp;quot;&amp;gt;Denlinger (2008), p. 12-64.&amp;lt;/ref&amp;gt; The procedure applied to anything leaving the exclusion and contamination reduction areas, including personnel, protective equipment, monitoring equipment and clean-up equipment.&amp;lt;ref name=&amp;quot;LV-A-5.3&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-deleted&quot;&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-deleted&quot;&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;[[File:fse-decontamination-v5.jpg|thumb|upright=1.5|alt=Responder in a chemical suit standing in a collection basin while a protected team member rinses the suit during an exercise|Decontamination of a responder in chemical protective clothing during a hazardous materials exercise.]]&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The procedure had nine steps. An entry point was marked to guide contaminated personnel into the area, and protective clothing was removed and isolated in sealed plastic bags placed in recovery drums.&amp;lt;ref name=&amp;quot;LV-A-5.3.2&amp;quot; /&amp;gt; Members then entered the rear of the unit under the supervision of emergency medical service (EMS) personnel, removed personal effects and work clothing, and showered.&amp;lt;ref name=&amp;quot;LV-A-5.3.2&amp;quot; /&amp;gt; After showering they received towels and clothing and left the unit.&amp;lt;ref name=&amp;quot;LV-A-5.3.2&amp;quot; /&amp;gt; EMS personnel then took a medical history, checked vital signs and followed up complaints, usually in a medical vehicle on the clean side, and transported members who needed further care.&amp;lt;ref name=&amp;quot;LV-A-5.3.2&amp;quot; /&amp;gt; Finally, the unit was disconnected, and the Department of Environmental Protection analysed the shower waste water.&amp;lt;ref name=&amp;quot;LV-A-5.3.2&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The procedure had nine steps. An entry point was marked to guide contaminated personnel into the area, and protective clothing was removed and isolated in sealed plastic bags placed in recovery drums.&amp;lt;ref name=&amp;quot;LV-A-5.3.2&amp;quot; /&amp;gt; Members then entered the rear of the unit under the supervision of emergency medical service (EMS) personnel, removed personal effects and work clothing, and showered.&amp;lt;ref name=&amp;quot;LV-A-5.3.2&amp;quot; /&amp;gt; After showering they received towels and clothing and left the unit.&amp;lt;ref name=&amp;quot;LV-A-5.3.2&amp;quot; /&amp;gt; EMS personnel then took a medical history, checked vital signs and followed up complaints, usually in a medical vehicle on the clean side, and transported members who needed further care.&amp;lt;ref name=&amp;quot;LV-A-5.3.2&amp;quot; /&amp;gt; Finally, the unit was disconnected, and the Department of Environmental Protection analysed the shower waste water.&amp;lt;ref name=&amp;quot;LV-A-5.3.2&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;

&lt;!-- diff cache key firesb_pjbsiy42-wiki_:diff:1.41:old-4293:rev-5284:php=table --&gt;
&lt;/table&gt;</summary>
		<author><name>Linda</name></author>
	</entry>
	<entry>
		<id>https://fire-safety.academy/w/index.php?title=Decontamination&amp;diff=4293&amp;oldid=prev</id>
		<title>Lisa: FSE wiki: fact-check corrections (written by Claude Opus 5.5)</title>
		<link rel="alternate" type="text/html" href="https://fire-safety.academy/w/index.php?title=Decontamination&amp;diff=4293&amp;oldid=prev"/>
		<updated>2026-11-08T02:39:49Z</updated>

		<summary type="html">&lt;p&gt;FSE wiki: fact-check corrections (written by Claude Opus 5.5)&lt;/p&gt;
&lt;a href=&quot;https://fire-safety.academy/w/index.php?title=Decontamination&amp;amp;diff=4293&amp;amp;oldid=3364&quot;&gt;Show changes&lt;/a&gt;</summary>
		<author><name>Lisa</name></author>
	</entry>
	<entry>
		<id>https://fire-safety.academy/w/index.php?title=Decontamination&amp;diff=3364&amp;oldid=prev</id>
		<title>Lisa: New FSE wiki article: Decontamination (written by Claude Opus 5.5)</title>
		<link rel="alternate" type="text/html" href="https://fire-safety.academy/w/index.php?title=Decontamination&amp;diff=3364&amp;oldid=prev"/>
		<updated>2026-11-07T21:21:46Z</updated>

		<summary type="html">&lt;p&gt;New FSE wiki article: Decontamination (written by Claude Opus 5.5)&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;&amp;#039;&amp;#039;&amp;#039;Decontamination&amp;#039;&amp;#039;&amp;#039;, also called contamination reduction, is the removal or neutralisation of contaminants from people and equipment after a hazardous materials release, so that foreseeable adverse health effects do not occur outside the area of exposure.&amp;lt;ref name=&amp;quot;Wr-13-140&amp;quot;&amp;gt;C. J. Wright (2008a), p. 13-140.&amp;lt;/ref&amp;gt; In the response model of the &amp;#039;&amp;#039;Fire Protection Handbook&amp;#039;&amp;#039; (20th edition, 2008), a decontamination process is chosen for every response option.&amp;lt;ref name=&amp;quot;Wr-13-137&amp;quot;&amp;gt;C. J. Wright (2008a), p. 13-137.&amp;lt;/ref&amp;gt; It is carried out in the warm zone, between the contaminated hot zone and the clean cold zone.&amp;lt;ref name=&amp;quot;Wr-13-142&amp;quot;&amp;gt;C. J. Wright (2008a), p. 13-142.&amp;lt;/ref&amp;gt; Possible methods are absorption, adsorption, chemical degradation, dilution, neutralisation and solidification, tailored to the hazards of the incident.&amp;lt;ref name=&amp;quot;Wr-13-140&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
A New York City fire department plan of 1994 calls decontamination one of the most important steps in ensuring personal safety at a hazardous materials emergency.&amp;lt;ref name=&amp;quot;LV-A-3.3&amp;quot;&amp;gt;Lawson and Vettori (2005), Appendix A, FDNY hazardous materials plan, §3.3.&amp;lt;/ref&amp;gt; Its personnel procedure includes showers and a medical check.&amp;lt;ref name=&amp;quot;LV-A-5.3&amp;quot;&amp;gt;Lawson and Vettori (2005), Appendix A, FDNY hazardous materials plan, §5.3.&amp;lt;/ref&amp;gt; Decontamination also covers protective clothing, tools and apparatus, but some garments cannot be cleaned and must be discarded.&amp;lt;ref name=&amp;quot;Tee-12-146&amp;quot;&amp;gt;Teele (2008), p. 12-146.&amp;lt;/ref&amp;gt; The sources also describe decontamination after radioactive releases and, in a Dutch study, of firefighters&amp;#039; clothing after fires in electric vehicles.&amp;lt;ref name=&amp;quot;Dav-7-53&amp;quot;&amp;gt;Davenport (2008), p. 7-53.&amp;lt;/ref&amp;gt;&amp;lt;ref name=&amp;quot;VdG-30&amp;quot;&amp;gt;Van der Graaf et al. (2021/2023), p. 30.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== Definition and purpose ==&lt;br /&gt;
C. J. Wright defines decontamination, or contamination reduction, as the act of removing or neutralising contaminants from equipment or personnel to preclude foreseeable adverse health effects outside the engulfed area.&amp;lt;ref name=&amp;quot;Wr-13-140&amp;quot; /&amp;gt; The engulfed area is the actual or potential area of exposure to a hazardous material.&amp;lt;ref name=&amp;quot;Wr-13-134&amp;quot;&amp;gt;C. J. Wright (2008a), p. 13-134.&amp;lt;/ref&amp;gt; The plan of the Fire Department of the City of New York (FDNY) gives a similar definition. Decontamination is the process of making personnel, equipment and supplies safe by reducing present levels of poisonous or otherwise harmful substances.&amp;lt;ref name=&amp;quot;LV-A-3.3&amp;quot; /&amp;gt; Neither the &amp;#039;&amp;#039;SFPE Handbook&amp;#039;&amp;#039; nor &amp;#039;&amp;#039;Introduction to Fire Safety Engineering&amp;#039;&amp;#039; defines the term, so both definitions come from fire service documents.&lt;br /&gt;
&lt;br /&gt;
The need arises because personnel, protective equipment, apparatus, tools and equipment may become contaminated at a hazardous materials incident.&amp;lt;ref name=&amp;quot;Wr-13-140&amp;quot; /&amp;gt; Decontamination is part of the system that prevents or reduces the physical transfer of contaminants from the site by people and equipment.&amp;lt;ref name=&amp;quot;LV-A-5.3&amp;quot; /&amp;gt; The FDNY plan treats site control as two activities: the physical arrangement and control of the work areas, and the removal of contaminants from people and equipment.&amp;lt;ref name=&amp;quot;LV-A-3.2&amp;quot;&amp;gt;Lawson and Vettori (2005), Appendix A, FDNY hazardous materials plan, §3.2.&amp;lt;/ref&amp;gt; The plan adds that the success of decontamination depends on the ability of the incident commander to keep control of personnel at the site.&amp;lt;ref name=&amp;quot;LV-A-3.3&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Two related terms appear in the sources. NFPA 473 separates two levels of emergency medical responders according to whether their patients still pose a significant risk of secondary contamination.&amp;lt;ref name=&amp;quot;HN-13-96&amp;quot;&amp;gt;Hildebrand and Noll (2008), p. 13-96.&amp;lt;/ref&amp;gt; Loflin describes cross-contamination by protective clothing. Clothing worn at an incident scene can contain harmful contaminants, and the possibility of such cross-contamination is real.&amp;lt;ref name=&amp;quot;Lof-12-115&amp;quot;&amp;gt;Loflin (2008), p. 12-115.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== Place in the hazardous materials response ==&lt;br /&gt;
In the [[hazardous materials response]] model described by Wright, decontamination appears in each duty. During planning, responders identify an appropriate decontamination process for each response option, alongside its protective equipment.&amp;lt;ref name=&amp;quot;Wr-13-137&amp;quot; /&amp;gt; Materials for decontamination are among the resources counted when an option is selected, and decontamination procedures form one of the ten components of the plan of action.&amp;lt;ref name=&amp;quot;Wr-13-141&amp;quot;&amp;gt;C. J. Wright (2008a), p. 13-141.&amp;lt;/ref&amp;gt; During implementation, decontamination is set up together with the control zones as part of scene control.&amp;lt;ref name=&amp;quot;Wr-13-142&amp;quot; /&amp;gt; The final duty, evaluating progress, includes a check on how well the decontamination process is working.&amp;lt;ref name=&amp;quot;Wr-13-143&amp;quot;&amp;gt;C. J. Wright (2008a), p. 13-143.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
In the United States, the Hazardous Waste Operations and Emergency Response (HAZWOPER) rule in the Code of Federal Regulations (29 CFR 1910.120) links decontamination to each responder level. First responders at the operations level must know how to implement basic decontamination measures, and technicians must understand and implement decontamination procedures.&amp;lt;ref name=&amp;quot;HN-13-89&amp;quot;&amp;gt;Hildebrand and Noll (2008), p. 13-89.&amp;lt;/ref&amp;gt; Specialists must be able to determine and implement them, and the on-scene incident commander must know and understand their importance.&amp;lt;ref name=&amp;quot;HN-13-90&amp;quot;&amp;gt;Hildebrand and Noll (2008), p. 13-90.&amp;lt;/ref&amp;gt; NFPA 471, the recommended practice for responding to hazardous materials incidents, also covers decontamination.&amp;lt;ref name=&amp;quot;HN-13-95&amp;quot;&amp;gt;Hildebrand and Noll (2008), p. 13-95.&amp;lt;/ref&amp;gt; An industrial fire brigade that acts as a hazmat team must have specific personnel decontamination procedures so that team members can safely leave a contaminated area.&amp;lt;ref name=&amp;quot;Sny-12-197&amp;quot;&amp;gt;Snyder (2008), p. 12-197.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Within an [[incident command system]], decontamination can be organised as a functional unit. The FDNY glossary of 1991 names a decon group as an example of a group, an organisational level with a specified functional assignment under a group supervisor.&amp;lt;ref name=&amp;quot;LV-A-gloss&amp;quot;&amp;gt;Lawson and Vettori (2005), Appendix A, FDNY ICS glossary, &amp;quot;Group&amp;quot;.&amp;lt;/ref&amp;gt; In the 1994 plan, a decontamination team of at least two members of the Hazardous Materials Unit managed the control zones and access control points.&amp;lt;ref name=&amp;quot;LV-A-4.3.4&amp;quot;&amp;gt;Lawson and Vettori (2005), Appendix A, FDNY hazardous materials plan, §4.3.4.&amp;lt;/ref&amp;gt; The same team set up the decontamination area, decontaminated the hazardous materials team and overpacked exposed equipment for further treatment or disposal.&amp;lt;ref name=&amp;quot;LV-A-4.3.4&amp;quot; /&amp;gt; A decontamination officer of the Special Operations Command was responsible for on-site and off-site decontamination, and determined the procedure together with the city&amp;#039;s Department of Environmental Protection.&amp;lt;ref name=&amp;quot;LV-A-4.3.6&amp;quot;&amp;gt;Lawson and Vettori (2005), Appendix A, FDNY hazardous materials plan, §4.3.6.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== Methods and selection of a process ==&lt;br /&gt;
Wright names six possible decontamination options: absorption, adsorption, chemical degradation, dilution, neutralisation and solidification.&amp;lt;ref name=&amp;quot;Wr-13-140&amp;quot; /&amp;gt; Procedures should be tailored to the specific hazards of the incident, and may vary in complexity and number of steps with the level of hazard and of exposure.&amp;lt;ref name=&amp;quot;Wr-13-140&amp;quot; /&amp;gt; The FDNY plan gives two extremes. An uncontaminated light oil with minimal hazard can be partially removed by flushing it from protective clothing, whereas a poisonous material requires a careful and detailed course of action.&amp;lt;ref name=&amp;quot;LV-A-3.3&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Wright lists four steps for selecting a process. The first is to identify what needs decontamination: injured persons, response personnel, protective equipment, other equipment and emergency-care facilities.&amp;lt;ref name=&amp;quot;Wr-13-140&amp;quot; /&amp;gt; The second is to determine the contaminant and the type and amount of contamination.&amp;lt;ref name=&amp;quot;Wr-13-141&amp;quot; /&amp;gt; Relevant questions are whether the material is organic or inorganic, solid, liquid or gas, a skin or inhalation hazard, and local or systemic in its effect.&amp;lt;ref name=&amp;quot;Wr-13-141&amp;quot; /&amp;gt; Responders also judge whether it is life threatening, injurious or irritating, and whether physical trauma is involved.&amp;lt;ref name=&amp;quot;Wr-13-141&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
The third step is to seek advice. Immediate decontamination guidance is found in the first-aid sections of the numbered guide pages of the Emergency Response Guidebook.&amp;lt;ref name=&amp;quot;Wr-13-141&amp;quot; /&amp;gt; Other immediate sources are the pocket guide to chemical hazards of the National Institute of Occupational Safety and Health (NIOSH) and local planning documents.&amp;lt;ref name=&amp;quot;Wr-13-141&amp;quot; /&amp;gt; Follow-up guidance can come from poison control centres, from the shipper or manufacturer through CHEMTREC, and from the Agency for Toxic Substances and Disease Registry.&amp;lt;ref name=&amp;quot;Wr-13-141&amp;quot; /&amp;gt; The fourth step is to identify how clothing and equipment that cannot be decontaminated will be isolated, secured and disposed of.&amp;lt;ref name=&amp;quot;Wr-13-141&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Water was the usual medium in the FDNY procedure, but not always. Members showered for a period set by the substance involved, except where the substance is made more active by water.&amp;lt;ref name=&amp;quot;LV-A-5.3.2&amp;quot;&amp;gt;Lawson and Vettori (2005), Appendix A, FDNY hazardous materials plan, §5.3.2.&amp;lt;/ref&amp;gt; The steps were designed for worst-case incidents, and the decision to apply all or part of them was to rest on a field analysis of the hazards and risks.&amp;lt;ref name=&amp;quot;LV-A-5.3.2&amp;quot; /&amp;gt; The toxicological and reactivity information that decided which techniques applied came from the Hazardous Materials Unit and the city departments of health and environmental protection.&amp;lt;ref name=&amp;quot;LV-A-5.3.2&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== The decontamination corridor ==&lt;br /&gt;
Decontamination takes place in the warm zone, the area between the hot zone around the release and the cold zone with the command post.&amp;lt;ref name=&amp;quot;Wr-13-142&amp;quot; /&amp;gt; Wright&amp;#039;s diagram of control zones shows a decontamination corridor crossing the warm zone, with access control points on the hot line and on the contamination control line.&amp;lt;ref name=&amp;quot;Wr-13-143&amp;quot; /&amp;gt; The FDNY plan called this zone the contamination reduction area and stated that all decontamination activities occur there.&amp;lt;ref name=&amp;quot;LV-A-5.2.2&amp;quot;&amp;gt;Lawson and Vettori (2005), Appendix A, FDNY hazardous materials plan, §5.2.2.&amp;lt;/ref&amp;gt; Its purpose is to prevent or reduce the transfer of contaminants picked up by personnel or equipment returning from the exclusion area, the plan&amp;#039;s term for the hot zone.&amp;lt;ref name=&amp;quot;LV-A-5.2.2&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Two lines bound the corridor. The hot line separates the exclusion area from the contamination reduction area, and a decontamination station for personnel or equipment is set up close to it.&amp;lt;ref name=&amp;quot;LV-A-5.2.2&amp;quot; /&amp;gt; The contamination control line separates the possibly contaminated area from the clean zone. Leaving the contamination reduction area for the clean area requires removal of suspected or known contaminated clothing and equipment.&amp;lt;ref name=&amp;quot;LV-A-5.2.2&amp;quot; /&amp;gt; Unless otherwise demonstrated, everything leaving the exclusion area is considered contaminated.&amp;lt;ref name=&amp;quot;LV-A-5.2.1&amp;quot;&amp;gt;Lawson and Vettori (2005), Appendix A, FDNY hazardous materials plan, §5.2.1.&amp;lt;/ref&amp;gt; Potentially contaminated clothing and equipment are not permitted in the support area, where normal fire-fighting clothing is worn.&amp;lt;ref name=&amp;quot;LV-A-5.2.3&amp;quot;&amp;gt;Lawson and Vettori (2005), Appendix A, FDNY hazardous materials plan, §5.2.3.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
The FDNY plan based its three-zone system and exacting decontamination procedures on a worst-case situation.&amp;lt;ref name=&amp;quot;LV-A-5.2.5&amp;quot;&amp;gt;Lawson and Vettori (2005), Appendix A, FDNY hazardous materials plan, §5.2.5.&amp;lt;/ref&amp;gt; Less stringent site control and decontamination could be used once air monitoring, instrument surveys and technical data gave more accurate information about the contaminants.&amp;lt;ref name=&amp;quot;LV-A-5.2.5&amp;quot; /&amp;gt; A hazardous materials incident safety officer should ensure that hot, warm, decontamination and other zone designations are clearly marked and communicated to all members.&amp;lt;ref name=&amp;quot;Lof-12-112&amp;quot;&amp;gt;Loflin (2008), p. 12-112.&amp;lt;/ref&amp;gt; People working in the corridor face their own exposure: Wright lists splashes during the decontamination of people or equipment among the exposure types to consider when selecting protective equipment.&amp;lt;ref name=&amp;quot;Wr-13-139&amp;quot;&amp;gt;C. J. Wright (2008a), p. 13-139.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== Personnel decontamination: the New York City procedure of 1994 ==&lt;br /&gt;
The FDNY plan, reproduced by the National Institute of Standards and Technology (NIST) in its report on the World Trade Center emergency response, sets out a complete personnel procedure. FDNY kept a Hazardous Materials Decontamination Unit consisting of a decontamination trailer and a support unit, and the police department had a similar unit as backup.&amp;lt;ref name=&amp;quot;LV-A-5.3.1&amp;quot;&amp;gt;Lawson and Vettori (2005), Appendix A, FDNY hazardous materials plan, §5.3.1.&amp;lt;/ref&amp;gt; Elsewhere in the United States, some departments acquired mobile decontamination trailers as part of domestic preparedness work.&amp;lt;ref name=&amp;quot;Den-12-64&amp;quot;&amp;gt;Denlinger (2008), p. 12-64.&amp;lt;/ref&amp;gt; The procedure applied to anything leaving the exclusion and contamination reduction areas, including personnel, protective equipment, monitoring equipment and clean-up equipment.&amp;lt;ref name=&amp;quot;LV-A-5.3&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
The procedure had nine steps. An entry point was marked to guide contaminated personnel into the area, and protective clothing was removed and isolated in sealed plastic bags placed in recovery drums.&amp;lt;ref name=&amp;quot;LV-A-5.3.2&amp;quot; /&amp;gt; Members then entered the rear of the unit under the supervision of emergency medical service (EMS) personnel, removed personal effects and work clothing, and showered.&amp;lt;ref name=&amp;quot;LV-A-5.3.2&amp;quot; /&amp;gt; After showering they received towels and clothing and left the unit.&amp;lt;ref name=&amp;quot;LV-A-5.3.2&amp;quot; /&amp;gt; EMS personnel then took a medical history, checked vital signs and followed up complaints, usually in a medical vehicle on the clean side, and transported members who needed further care.&amp;lt;ref name=&amp;quot;LV-A-5.3.2&amp;quot; /&amp;gt; Finally, the unit was disconnected, and the Department of Environmental Protection analysed the shower waste water.&amp;lt;ref name=&amp;quot;LV-A-5.3.2&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
The plan also tracked people and equipment. The Safety Operating Battalion Chief confirmed that all exposed members took part in the decontamination procedure, and recorded their names and units with a description of the procedures used.&amp;lt;ref name=&amp;quot;LV-A-6.1&amp;quot;&amp;gt;Lawson and Vettori (2005), Appendix A, FDNY hazardous materials plan, §6.1.&amp;lt;/ref&amp;gt; Apparatus, tools, clothing and personal items stayed at the site until a member of the Special Operations Command had decided what needed decontamination.&amp;lt;ref name=&amp;quot;LV-A-5.3.3&amp;quot;&amp;gt;Lawson and Vettori (2005), Appendix A, FDNY hazardous materials plan, §5.3.3.&amp;lt;/ref&amp;gt; Potentially contaminated breathing-air cylinders were not to be exchanged.&amp;lt;ref name=&amp;quot;LV-A-6.6&amp;quot;&amp;gt;Lawson and Vettori (2005), Appendix A, FDNY hazardous materials plan, §6.6.&amp;lt;/ref&amp;gt; Decontamination was done at the scene where possible, so that apparatus and equipment could return to service; otherwise the decontamination officer set a time and site.&amp;lt;ref name=&amp;quot;LV-A-4.3.6&amp;quot; /&amp;gt; Every incident involving decontamination was included in the post-incident review.&amp;lt;ref name=&amp;quot;LV-A-9.1&amp;quot;&amp;gt;Lawson and Vettori (2005), Appendix A, FDNY hazardous materials plan, §9.1.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== Protective clothing, equipment and fire stations ==&lt;br /&gt;
Protective clothing is both a barrier against contamination and a possible carrier of it. Teele notes that decontamination may not be possible when protective garments are contaminated with chemical, radiological or biological agents. Such garments should then be discarded in line with local, state and federal regulations.&amp;lt;ref name=&amp;quot;Tee-12-146&amp;quot; /&amp;gt; Chlorine bleach must not be used for any cleaning, decontamination or disinfection of protective equipment, because some components lose their physical integrity or flame resistance.&amp;lt;ref name=&amp;quot;Tee-12-146&amp;quot; /&amp;gt; For [[chemical protective clothing]] certified to NFPA 1991 or NFPA 1992, the manufacturer&amp;#039;s technical data should include decontamination procedures.&amp;lt;ref name=&amp;quot;Tee-12-157&amp;quot;&amp;gt;Teele (2008), p. 12-157.&amp;lt;/ref&amp;gt; Where a suit allows a choice, wearing the breathing apparatus inside the ensemble is strongly recommended, partly to reduce decontamination problems.&amp;lt;ref name=&amp;quot;Tee-12-157&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Some ensembles are not meant to be decontaminated at all. NFPA 1994 ensembles for chemical, biological, radiological and nuclear (CBRN) terrorism incidents are intended as single-exposure equipment that is discarded after use.&amp;lt;ref name=&amp;quot;Tee-12-158&amp;quot;&amp;gt;Teele (2008), p. 12-158.&amp;lt;/ref&amp;gt; They protect personnel exposed to victims or materials during assessment, rescue, decontamination, triage and treatment, and their classes consider the threat of contamination and cross-contamination.&amp;lt;ref name=&amp;quot;Tee-12-158&amp;quot; /&amp;gt; The military calls such agents [[weapons of mass destruction]].&amp;lt;ref name=&amp;quot;Tee-12-157&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Fire stations need facilities for the same purpose. Acomb and LeBoeuf assume that station personnel, whether they provide [[fire-based emergency medical services|emergency medical care]] or hazardous materials response, will at some time meet a contamination problem requiring complete clothing removal.&amp;lt;ref name=&amp;quot;AL-12-239&amp;quot;&amp;gt;Acomb and LeBoeuf (2008), p. 12-239.&amp;lt;/ref&amp;gt; A decontamination room or space must then let personnel remove their outer clothing and clean their skin without contaminating the rest of the station.&amp;lt;ref name=&amp;quot;AL-12-239&amp;quot; /&amp;gt; Its equipment includes foot-activated hampers, motion- or foot-operated wash basins, automatic showers and doors, and spare clothes; a direct exterior entrance keeps contamination from spreading.&amp;lt;ref name=&amp;quot;AL-12-239&amp;quot; /&amp;gt; Laundry rooms with commercial machines clean turnout gear, because few commercial laundries will wash it.&amp;lt;ref name=&amp;quot;AL-12-240&amp;quot;&amp;gt;Acomb and LeBoeuf (2008), p. 12-240.&amp;lt;/ref&amp;gt; Under NFPA 1581, as described by Loflin, departments had to clean fire fighters&amp;#039; protective clothing at least every 6 months.&amp;lt;ref name=&amp;quot;Lof-12-115&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== Patients, hospitals and wider contamination ==&lt;br /&gt;
Contaminated victims add a medical dimension. Wright warns that extreme caution is necessary when giving emergency medical care to victims of hazardous material incidents.&amp;lt;ref name=&amp;quot;Wr-13-143&amp;quot; /&amp;gt; Under NFPA 473, Level I personnel treat in the cold zone only patients who no longer pose a significant risk of secondary contamination.&amp;lt;ref name=&amp;quot;HN-13-96&amp;quot; /&amp;gt; Level II personnel work in the warm zone and may treat patients who still pose such a risk.&amp;lt;ref name=&amp;quot;HN-13-96&amp;quot; /&amp;gt; The FDNY plan required people exposed before a hazardous substance was recognised to be isolated, to avoid spreading contamination and to allow medical treatment and monitoring.&amp;lt;ref name=&amp;quot;LV-A-5.3&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Victims who leave the scene on their own create a separate problem. For mass casualty incidents, Teele notes that civilian victims may arrive at medical facilities without having been decontaminated at the scene, so medical first receivers should have protective equipment.&amp;lt;ref name=&amp;quot;Tee-12-156&amp;quot;&amp;gt;Teele (2008), p. 12-156.&amp;lt;/ref&amp;gt; Contamination can also be costly. Whitford reports that, after a pesticide release, the decontamination of ambulances and hospital rooms can reach thousands of dollars.&amp;lt;ref name=&amp;quot;Whi-6-234&amp;quot;&amp;gt;Whitford (2008), p. 6-234.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Decontamination also extends to buildings. Where radioactive materials are involved, Davenport calls the need to decontaminate buildings, equipment and materials a serious and complicated problem.&amp;lt;ref name=&amp;quot;Dav-7-53&amp;quot; /&amp;gt; Holmes notes that this necessity can delay salvage and the resumption of normal operations.&amp;lt;ref name=&amp;quot;Hol-9-199&amp;quot;&amp;gt;Holmes (2008a), p. 9-199.&amp;lt;/ref&amp;gt; For nuclear facilities, he advises emergency plans that prevent the spread of contamination and promptly decontaminate the area after a release.&amp;lt;ref name=&amp;quot;Hol-9-199&amp;quot; /&amp;gt; A nuclear reactor site needs a generous water supply for fire control and decontamination, and prearranged disposal or storage of contaminated water.&amp;lt;ref name=&amp;quot;Hol-9-199&amp;quot; /&amp;gt; Severson adds that extensive decontamination may become necessary if combustion products of long-lived radioactive waste spread through air-conditioning or compressed-air systems.&amp;lt;ref name=&amp;quot;Sev-7-67&amp;quot;&amp;gt;Severson (2008), p. 7-67.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
A Dutch report on indoor car parks by Van der Graaf, Hessels and Rosmuller gives a fire service example from the Netherlands. Fires in electric vehicles release toxic gases ([[fire toxicity]]), among them hydrogen fluoride (HF).&amp;lt;ref name=&amp;quot;VdG-26&amp;quot;&amp;gt;Van der Graaf et al. (2021/2023), p. 26.&amp;lt;/ref&amp;gt; Larsson and colleagues found that about 20 to 200 mg of HF is released per Wh of battery capacity.&amp;lt;ref name=&amp;quot;Lars&amp;quot;&amp;gt;Larsson et al. (2017), as cited in Van der Graaf et al. (2021/2023), p. 26.&amp;lt;/ref&amp;gt; According to the report, a 100 kWh battery pack can emit 2 to 20 kg of HF, depending on its state of charge.&amp;lt;ref name=&amp;quot;VdG-26&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Because HF deposits on surfaces and smoke particles, firefighting clothing becomes more contaminated.&amp;lt;ref name=&amp;quot;VdG-26&amp;quot; /&amp;gt; Citing the Dutch National Institute for Public Health and the Environment (RIVM), the report states that fighting such a fire requires the firefighters&amp;#039; clothing to be decontaminated, unlike a fire in a conventionally powered vehicle.&amp;lt;ref name=&amp;quot;VdG-30&amp;quot; /&amp;gt; The report also recommends that contaminated cooling water from an immersion tank is not discharged directly into the sewer.&amp;lt;ref name=&amp;quot;VdG-47&amp;quot;&amp;gt;Van der Graaf et al. (2021/2023), p. 47.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== Limits and common misconceptions ==&lt;br /&gt;
Decontamination is not always possible or complete. Some garments cannot be decontaminated and must be discarded, and some ensembles are designed to be thrown away after a single exposure.&amp;lt;ref name=&amp;quot;Tee-12-146&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;Tee-12-158&amp;quot; /&amp;gt; Water, the usual medium for showers and flushing, can be the wrong choice for substances made more active by water.&amp;lt;ref name=&amp;quot;LV-A-5.3.2&amp;quot; /&amp;gt; Wright&amp;#039;s selection process includes, as a separate step, plans for isolating, securing and disposing of clothing and equipment that cannot be decontaminated.&amp;lt;ref name=&amp;quot;Wr-13-141&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Decontamination is also distinct from clean-up of the site. In the FDNY plan, clean-up removed the hazardous material and all contaminated debris, including soil, water, containers, vehicles, tools and equipment.&amp;lt;ref name=&amp;quot;LV-A-8.1&amp;quot;&amp;gt;Lawson and Vettori (2005), Appendix A, FDNY hazardous materials plan, §8.1.&amp;lt;/ref&amp;gt; Clean-up was not a fire department function, although the department had to ensure that it took place.&amp;lt;ref name=&amp;quot;LV-A-8.1&amp;quot; /&amp;gt; Decontamination, by contrast, deals with people and equipment leaving the contaminated zones.&amp;lt;ref name=&amp;quot;LV-A-5.3&amp;quot; /&amp;gt; Its waste water is a further concern, which the FDNY plan addressed by having shower water analysed.&amp;lt;ref name=&amp;quot;LV-A-5.3.2&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
The sources describe US practice between 1994 and 2008 and, for electric vehicles, Dutch research published in 2021. The handbook describes NFPA 1994 in its 2007 edition but gives no edition for the other standards mentioned, which may since have changed.&amp;lt;ref name=&amp;quot;Tee-12-158&amp;quot; /&amp;gt; The procedures in this article are therefore examples of documented practice rather than universal requirements.&lt;br /&gt;
&lt;br /&gt;
== See also ==&lt;br /&gt;
* [[Fire station design]]&lt;br /&gt;
* [[Emergency Response Guidebook]]&lt;br /&gt;
* [[Structural firefighting protective clothing]]&lt;br /&gt;
* [[Self-contained breathing apparatus]]&lt;br /&gt;
* [[Incident safety officer]]&lt;br /&gt;
&lt;br /&gt;
== Notes ==&lt;br /&gt;
&amp;lt;references /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== References ==&lt;br /&gt;
* Acomb, D. J., &amp;amp; LeBoeuf, R. M. (2008). Fire rescue stations and fire service training centers. In A. E. Cote, C. C. Grant, J. R. Hall, Jr., &amp;amp; R. E. Solomon (Eds.), &amp;#039;&amp;#039;Fire protection handbook&amp;#039;&amp;#039; (20th ed., pp. 12-233–12-251). National Fire Protection Association.&lt;br /&gt;
* Davenport, J. A. (2008). Storage and handling of chemicals. In A. E. Cote, C. C. Grant, J. R. Hall, Jr., &amp;amp; R. E. Solomon (Eds.), &amp;#039;&amp;#039;Fire protection handbook&amp;#039;&amp;#039; (20th ed., pp. 7-43–7-55). National Fire Protection Association.&lt;br /&gt;
* Denlinger, R. F. (2008). Managing fire-rescue departments. In A. E. Cote, C. C. Grant, J. R. Hall, Jr., &amp;amp; R. E. Solomon (Eds.), &amp;#039;&amp;#039;Fire protection handbook&amp;#039;&amp;#039; (20th ed., pp. 12-51–12-78). National Fire Protection Association.&lt;br /&gt;
* Hildebrand, M. S., &amp;amp; Noll, G. G. (2008). Public fire protection and hazmat management. In A. E. Cote, C. C. Grant, J. R. Hall, Jr., &amp;amp; R. E. Solomon (Eds.), &amp;#039;&amp;#039;Fire protection handbook&amp;#039;&amp;#039; (20th ed., pp. 13-81–13-98). National Fire Protection Association.&lt;br /&gt;
* Holmes, W. D. (2008a). Nuclear facilities. In A. E. Cote, C. C. Grant, J. R. Hall, Jr., &amp;amp; R. E. Solomon (Eds.), &amp;#039;&amp;#039;Fire protection handbook&amp;#039;&amp;#039; (20th ed., pp. 9-191–9-201). National Fire Protection Association.&lt;br /&gt;
* Lawson, J. R., &amp;amp; Vettori, R. L. (2005). &amp;#039;&amp;#039;The emergency response operations&amp;#039;&amp;#039; (NIST NCSTAR 1-8). National Institute of Standards and Technology.&lt;br /&gt;
* Loflin, M. E. (2008). Safety, medical, and health issues and programs. In A. E. Cote, C. C. Grant, J. R. Hall, Jr., &amp;amp; R. E. Solomon (Eds.), &amp;#039;&amp;#039;Fire protection handbook&amp;#039;&amp;#039; (20th ed., pp. 12-107–12-125). National Fire Protection Association.&lt;br /&gt;
* Severson, P. R. (2008). Hazardous waste control. In A. E. Cote, C. C. Grant, J. R. Hall, Jr., &amp;amp; R. E. Solomon (Eds.), &amp;#039;&amp;#039;Fire protection handbook&amp;#039;&amp;#039; (20th ed., pp. 7-57–7-69). National Fire Protection Association.&lt;br /&gt;
* Snyder, M. (2008). Industrial fire loss prevention. In A. E. Cote, C. C. Grant, J. R. Hall, Jr., &amp;amp; R. E. Solomon (Eds.), &amp;#039;&amp;#039;Fire protection handbook&amp;#039;&amp;#039; (20th ed., pp. 12-177–12-198). National Fire Protection Association.&lt;br /&gt;
* Teele, B. W. (2008). Fire and emergency services protective clothing and protective equipment. In A. E. Cote, C. C. Grant, J. R. Hall, Jr., &amp;amp; R. E. Solomon (Eds.), &amp;#039;&amp;#039;Fire protection handbook&amp;#039;&amp;#039; (20th ed., pp. 12-143–12-160). National Fire Protection Association.&lt;br /&gt;
* Van der Graaf, J., Hessels, T., &amp;amp; Rosmuller, N. (2023). &amp;#039;&amp;#039;Fire safety of indoor car parks accommodating electrically powered vehicles&amp;#039;&amp;#039;. Nederlands Instituut Publieke Veiligheid. (Original work published 2021)&lt;br /&gt;
* Whitford, F. (2008). Pesticides in the workplace. In A. E. Cote, C. C. Grant, J. R. Hall, Jr., &amp;amp; R. E. Solomon (Eds.), &amp;#039;&amp;#039;Fire protection handbook&amp;#039;&amp;#039; (20th ed., pp. 6-233–6-245). National Fire Protection Association.&lt;br /&gt;
* Wright, C. J. (2008a). Managing the response to hazardous material incidents. In A. E. Cote, C. C. Grant, J. R. Hall, Jr., &amp;amp; R. E. Solomon (Eds.), &amp;#039;&amp;#039;Fire protection handbook&amp;#039;&amp;#039; (20th ed., pp. 13-117–13-144). National Fire Protection Association.&lt;br /&gt;
&lt;br /&gt;
[[Category:Firefighting &amp;amp; Fire Service]]&lt;/div&gt;</summary>
		<author><name>Lisa</name></author>
	</entry>
</feed>