<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://fire-safety.academy/w/index.php?action=history&amp;feed=atom&amp;title=Commercial_vehicle_fire</id>
	<title>Commercial vehicle fire - Revision history</title>
	<link rel="self" type="application/atom+xml" href="https://fire-safety.academy/w/index.php?action=history&amp;feed=atom&amp;title=Commercial_vehicle_fire"/>
	<link rel="alternate" type="text/html" href="https://fire-safety.academy/w/index.php?title=Commercial_vehicle_fire&amp;action=history"/>
	<updated>2026-11-21T22:43:55Z</updated>
	<subtitle>Revision history for this page on the wiki</subtitle>
	<generator>MediaWiki 1.43.11</generator>
	<entry>
		<id>https://fire-safety.academy/w/index.php?title=Commercial_vehicle_fire&amp;diff=9446&amp;oldid=prev</id>
		<title>Peter: Wiki review: corrected 3 errors: typo (3) (Claude Opus 5.5)</title>
		<link rel="alternate" type="text/html" href="https://fire-safety.academy/w/index.php?title=Commercial_vehicle_fire&amp;diff=9446&amp;oldid=prev"/>
		<updated>2026-11-15T23:49:00Z</updated>

		<summary type="html">&lt;p&gt;Wiki review: corrected 3 errors: typo (3) (Claude Opus 5.5)&lt;/p&gt;
&lt;table style=&quot;background-color: #fff; color: #202122;&quot; data-mw=&quot;interface&quot;&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;tr class=&quot;diff-title&quot; lang=&quot;en&quot;&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;← Older revision&lt;/td&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;Revision as of 00:49, 16 November 2026&lt;/td&gt;
				&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l35&quot;&gt;Line 35:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 35:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[[File:fse-commercial-vehicle-fire-v1.svg|thumb|upright=1.5|alt=Range bars on a logarithmic scale comparing peak heat release rates of cars, buses, heavy goods vehicles and tankers from design tables and fire tests|Peak heat release rates of road vehicles: NFPA 502 (2008) design values and full-scale test results.]]&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[[File:fse-commercial-vehicle-fire-v1.svg|thumb|upright=1.5|alt=Range bars on a logarithmic scale comparing peak heat release rates of cars, buses, heavy goods vehicles and tankers from design tables and fire tests|Peak heat release rates of road vehicles: NFPA 502 (2008) design values and full-scale test results.]]&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;These numbers show why the load of an ordinary truck is the main uncertainty in a [[&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;Tunnel &lt;/del&gt;fire]]. Unlike transit tunnels, where the operator controls vehicles and loads, a road tunnel admits any truck.&amp;lt;ref name=&quot;Bendelius-21-189&quot;&amp;gt;Bendelius (2008), p. 21-189.&amp;lt;/ref&amp;gt; An innocent-looking truck may carry a load that supports a fast-growing, potentially lethal fire without being classed as hazardous cargo. The incident truck in the Mont Blanc fire carried mainly margarine and flour, and other tunnel fires involved tyres, cheese, glue and rolls of plastic.&amp;lt;ref name=&quot;Bendelius-21-191&quot;&amp;gt;Bendelius (2008), pp. 21-190–21-191.&amp;lt;/ref&amp;gt; The wood floors of trailers and buses, in contrast, are relatively hard to ignite, burn slowly and matter only in very severe incidents.&amp;lt;ref name=&quot;Routhier-21-20&quot;&amp;gt;Routhier (2008), p. 21-20.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;These numbers show why the load of an ordinary truck is the main uncertainty in a [[&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;tunnel &lt;/ins&gt;fire]]. Unlike transit tunnels, where the operator controls vehicles and loads, a road tunnel admits any truck.&amp;lt;ref name=&quot;Bendelius-21-189&quot;&amp;gt;Bendelius (2008), p. 21-189.&amp;lt;/ref&amp;gt; An innocent-looking truck may carry a load that supports a fast-growing, potentially lethal fire without being classed as hazardous cargo. The incident truck in the Mont Blanc fire carried mainly margarine and flour, and other tunnel fires involved tyres, cheese, glue and rolls of plastic.&amp;lt;ref name=&quot;Bendelius-21-191&quot;&amp;gt;Bendelius (2008), pp. 21-190–21-191.&amp;lt;/ref&amp;gt; The wood floors of trailers and buses, in contrast, are relatively hard to ignite, burn slowly and matter only in very severe incidents.&amp;lt;ref name=&quot;Routhier-21-20&quot;&amp;gt;Routhier (2008), p. 21-20.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Fuel spills and pool fires ==&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Fuel spills and pool fires ==&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l62&quot;&gt;Line 62:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 62:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Cargo tanks and hazardous materials ==&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Cargo tanks and hazardous materials ==&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;A [[&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;Cargo &lt;/del&gt;tank vehicle]], also called a tank truck or tank motor vehicle, is the most common vehicle for moving flammable, combustible and corrosive liquids and compressed gases by road.&amp;lt;ref name=&quot;Routhier-21-23&quot; /&amp;gt; When such a tank is involved in an accident, the disaster potential is substantial. Leakage can occur in both contact and non-contact accidents, and the main causes of unintentional release are poor maintenance and deviation from tank specifications.&amp;lt;ref name=&quot;Routhier-21-24&quot;&amp;gt;Routhier (2008), p. 21-24.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;A [[&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;cargo &lt;/ins&gt;tank vehicle]], also called a tank truck or tank motor vehicle, is the most common vehicle for moving flammable, combustible and corrosive liquids and compressed gases by road.&amp;lt;ref name=&quot;Routhier-21-23&quot; /&amp;gt; When such a tank is involved in an accident, the disaster potential is substantial. Leakage can occur in both contact and non-contact accidents, and the main causes of unintentional release are poor maintenance and deviation from tank specifications.&amp;lt;ref name=&quot;Routhier-21-24&quot;&amp;gt;Routhier (2008), p. 21-24.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The 2008 handbook describes tank vehicles built to NFPA 385 and US Department of Transportation rules as able to withstand all but the most violent impacts without rupturing.&amp;lt;ref name=&amp;quot;Ordile-7-31&amp;quot;&amp;gt;Ordile (2008), p. 7-31.&amp;lt;/ref&amp;gt; Vents let vapour burn at the vent if the tank is exposed to fire, reducing the risk of rupture from internal pressure. For liquids other than viscous ones, a shutoff valve inside the tank shell stays closed except during loading and unloading. A shear section in the piping breaks in an accident and leaves this valve undamaged and closed. A remote control and a fusible element that operates at no more than 121 °C (250 °F) let the valve close in a fire.&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The 2008 handbook describes tank vehicles built to NFPA 385 and US Department of Transportation rules as able to withstand all but the most violent impacts without rupturing.&amp;lt;ref name=&amp;quot;Ordile-7-31&amp;quot;&amp;gt;Ordile (2008), p. 7-31.&amp;lt;/ref&amp;gt; Vents let vapour burn at the vent if the tank is exposed to fire, reducing the risk of rupture from internal pressure. For liquids other than viscous ones, a shutoff valve inside the tank shell stays closed except during loading and unloading. A shear section in the piping breaks in an accident and leaves this valve undamaged and closed. A remote control and a fusible element that operates at no more than 121 °C (250 °F) let the valve close in a fire.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l74&quot;&gt;Line 74:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 74:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The FMCSA fuel tank rules described in the 2008 handbook closely followed UL standards and had applied to diesel tanks since 1973.&amp;lt;ref name=&amp;quot;Routhier-21-21&amp;quot; /&amp;gt; They required drop, rupture, vent and spillage tests, with a safety vent limiting the pressure rise to 345 kPa (50 psig) in a specified fire test. The handbook reported no FMVSS, NHTSA or FMCSA fire-retardance requirement for cargo trailers or truck bodies.&amp;lt;ref name=&amp;quot;Routhier-21-20&amp;quot; /&amp;gt; It described FMCSR requirements for flooring in good condition and a prohibition on floors soaked with oil or petrol.&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The FMCSA fuel tank rules described in the 2008 handbook closely followed UL standards and had applied to diesel tanks since 1973.&amp;lt;ref name=&amp;quot;Routhier-21-21&amp;quot; /&amp;gt; They required drop, rupture, vent and spillage tests, with a safety vent limiting the pressure rise to 345 kPa (50 psig) in a specified fire test. The handbook reported no FMVSS, NHTSA or FMCSA fire-retardance requirement for cargo trailers or truck bodies.&amp;lt;ref name=&amp;quot;Routhier-21-20&amp;quot; /&amp;gt; It described FMCSR requirements for flooring in good condition and a prohibition on floors soaked with oil or petrol.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The FMCSRs described in the 2008 handbook required commercial vehicles in interstate commerce to carry fire extinguishers and drivers to check them at the start of each trip.&amp;lt;ref name=&quot;Routhier-21-18&quot; /&amp;gt; A power unit without placardable hazardous materials needed a 5-B:C extinguisher or two 4-B:C extinguishers.&amp;lt;ref name=&quot;Routhier-21-22&quot; /&amp;gt; A power unit carrying hazardous materials needed a 10-B:C extinguisher. The [[&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;Fire &lt;/del&gt;extinguisher rating]] B:C means the unit is suitable for flammable liquid fires and fires in energised electrical equipment.&amp;lt;ref name=&quot;Rivkin-21-38&quot;&amp;gt;Rivkin (2008a), p. 21-38.&amp;lt;/ref&amp;gt; The number indicates its relative extinguishing power.&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The FMCSRs described in the 2008 handbook required commercial vehicles in interstate commerce to carry fire extinguishers and drivers to check them at the start of each trip.&amp;lt;ref name=&quot;Routhier-21-18&quot; /&amp;gt; A power unit without placardable hazardous materials needed a 5-B:C extinguisher or two 4-B:C extinguishers.&amp;lt;ref name=&quot;Routhier-21-22&quot; /&amp;gt; A power unit carrying hazardous materials needed a 10-B:C extinguisher. The [[&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;fire &lt;/ins&gt;extinguisher rating]] B:C means the unit is suitable for flammable liquid fires and fires in energised electrical equipment.&amp;lt;ref name=&quot;Rivkin-21-38&quot;&amp;gt;Rivkin (2008a), p. 21-38.&amp;lt;/ref&amp;gt; The number indicates its relative extinguishing power.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The 2002 SFPE handbook describes only a few US fire safety requirements for buses.&amp;lt;ref name=&amp;quot;Bukowski-5-228&amp;quot; /&amp;gt; These include FMVSS 302 limits on interior linings and seats, a fire-resistive barrier around the engine compartment and protection of the fuel tank against penetration. The barrier gives the driver time to stop the bus and let the passengers out, and some buses also have fixed extinguishing systems in the engine compartment.&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The 2002 SFPE handbook describes only a few US fire safety requirements for buses.&amp;lt;ref name=&amp;quot;Bukowski-5-228&amp;quot; /&amp;gt; These include FMVSS 302 limits on interior linings and seats, a fire-resistive barrier around the engine compartment and protection of the fuel tank against penetration. The barrier gives the driver time to stop the bus and let the passengers out, and some buses also have fixed extinguishing systems in the engine compartment.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;

&lt;!-- diff cache key firesb_pjbsiy42-wiki_:diff:1.41:old-6506:rev-9446:php=table --&gt;
&lt;/table&gt;</summary>
		<author><name>Peter</name></author>
	</entry>
	<entry>
		<id>https://fire-safety.academy/w/index.php?title=Commercial_vehicle_fire&amp;diff=6506&amp;oldid=prev</id>
		<title>Mark: Remove source references from image captions</title>
		<link rel="alternate" type="text/html" href="https://fire-safety.academy/w/index.php?title=Commercial_vehicle_fire&amp;diff=6506&amp;oldid=prev"/>
		<updated>2026-11-13T07:23:49Z</updated>

		<summary type="html">&lt;p&gt;Remove source references from image captions&lt;/p&gt;
&lt;table style=&quot;background-color: #fff; color: #202122;&quot; data-mw=&quot;interface&quot;&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;tr class=&quot;diff-title&quot; lang=&quot;en&quot;&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;← Older revision&lt;/td&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;Revision as of 08:23, 13 November 2026&lt;/td&gt;
				&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l23&quot;&gt;Line 23:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 23:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Tyres are a second typical source. If one tyre of a dual-tyre pair runs flat or is seriously underinflated, flexing can build up enough internal heat to ignite it.&amp;lt;ref name=&amp;quot;Routhier-21-22&amp;quot; /&amp;gt; Overloading, sustained high speed and high ambient temperatures add to this risk, and dual tyres spaced so closely that they rub can also ignite. Tyres can also be ignited by an overheated axle and then release a large amount of heat.&amp;lt;ref name=&amp;quot;Babrauskas-3-27&amp;quot;&amp;gt;Babrauskas (2002b), pp. 3-27–3-28.&amp;lt;/ref&amp;gt; The 2002 SFPE handbook cited one documented test: a burning pair of truck tyres in a tandem arrangement reached roughly 1 MW, read from its published curve.&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Tyres are a second typical source. If one tyre of a dual-tyre pair runs flat or is seriously underinflated, flexing can build up enough internal heat to ignite it.&amp;lt;ref name=&amp;quot;Routhier-21-22&amp;quot; /&amp;gt; Overloading, sustained high speed and high ambient temperatures add to this risk, and dual tyres spaced so closely that they rub can also ignite. Tyres can also be ignited by an overheated axle and then release a large amount of heat.&amp;lt;ref name=&amp;quot;Babrauskas-3-27&amp;quot;&amp;gt;Babrauskas (2002b), pp. 3-27–3-28.&amp;lt;/ref&amp;gt; The 2002 SFPE handbook cited one documented test: a burning pair of truck tyres in a tandem arrangement reached roughly 1 MW, read from its published curve.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[[File:fse-commercial-vehicle-fire-v2.svg|thumb|upright=1.5|alt=Side view of a tractor-trailer with numbered callouts at brakes, dual tyres, axle, exhaust, fuel line, battery and cargo|Typical ignition sources on a heavy goods vehicle&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;. Based on Routhier (2008), pp. 21-15–21-23, and Babrauskas (2002b), p. 3-27&lt;/del&gt;.]]&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[[File:fse-commercial-vehicle-fire-v2.svg|thumb|upright=1.5|alt=Side view of a tractor-trailer with numbered callouts at brakes, dual tyres, axle, exhaust, fuel line, battery and cargo|Typical ignition sources on a heavy goods vehicle.]]&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The fuel and electrical systems are a third source. Diesel has a higher [[Flash point|flash point]] than petrol, but diesel engines run hotter, so fuel in the return line is warmer and more likely to ignite if it leaks onto a hot surface.&amp;lt;ref name=&amp;quot;Routhier-21-21&amp;quot;&amp;gt;Routhier (2008), p. 21-21.&amp;lt;/ref&amp;gt; A manual battery disconnect switch is desirable on buses and trucks, but such switches are rarely fitted. For buses, the great majority of fires are engine fires.&amp;lt;ref name=&amp;quot;Bukowski-5-228&amp;quot; /&amp;gt; Cargo can also be ignited by careless smoking during loading, which is why motor carriers generally prohibit it.&amp;lt;ref name=&amp;quot;Routhier-21-23&amp;quot;&amp;gt;Routhier (2008), p. 21-23.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The fuel and electrical systems are a third source. Diesel has a higher [[Flash point|flash point]] than petrol, but diesel engines run hotter, so fuel in the return line is warmer and more likely to ignite if it leaks onto a hot surface.&amp;lt;ref name=&amp;quot;Routhier-21-21&amp;quot;&amp;gt;Routhier (2008), p. 21-21.&amp;lt;/ref&amp;gt; A manual battery disconnect switch is desirable on buses and trucks, but such switches are rarely fitted. For buses, the great majority of fires are engine fires.&amp;lt;ref name=&amp;quot;Bukowski-5-228&amp;quot; /&amp;gt; Cargo can also be ignited by careless smoking during loading, which is why motor carriers generally prohibit it.&amp;lt;ref name=&amp;quot;Routhier-21-23&amp;quot;&amp;gt;Routhier (2008), p. 21-23.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l33&quot;&gt;Line 33:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 33:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;As summarised in the handbook, NFPA 502 (2008 edition) gives peaks of 20–30 MW for a bus, 70–200 MW for a heavy goods truck and 200–300 MW for a tanker.&amp;lt;ref name=&amp;quot;Bendelius-21-204&amp;quot; /&amp;gt; The peak may be reached within 10 minutes, and temperatures directly above the fire can reach 1,000 to 1,400 °C. In the Memorial Tunnel test programme of 1993–1995 in West Virginia, a 20 MW test fire represented a bus or truck, 50 MW a large truck and 100 MW a petrol tanker.&amp;lt;ref name=&amp;quot;Bendelius-21-208&amp;quot;&amp;gt;Bendelius (2008), p. 21-208.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;As summarised in the handbook, NFPA 502 (2008 edition) gives peaks of 20–30 MW for a bus, 70–200 MW for a heavy goods truck and 200–300 MW for a tanker.&amp;lt;ref name=&amp;quot;Bendelius-21-204&amp;quot; /&amp;gt; The peak may be reached within 10 minutes, and temperatures directly above the fire can reach 1,000 to 1,400 °C. In the Memorial Tunnel test programme of 1993–1995 in West Virginia, a 20 MW test fire represented a bus or truck, 50 MW a large truck and 100 MW a petrol tanker.&amp;lt;ref name=&amp;quot;Bendelius-21-208&amp;quot;&amp;gt;Bendelius (2008), p. 21-208.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[[File:fse-commercial-vehicle-fire-v1.svg|thumb|upright=1.5|alt=Range bars on a logarithmic scale comparing peak heat release rates of cars, buses, heavy goods vehicles and tankers from design tables and fire tests|Peak heat release rates of road vehicles: NFPA 502 (2008) design values and full-scale test results&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;. Based on Bendelius (2008), p. 21-204, Mawhinney (2008), p. 16-140, and Babrauskas (2002b), pp. 3-27–3-28&lt;/del&gt;.]]&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[[File:fse-commercial-vehicle-fire-v1.svg|thumb|upright=1.5|alt=Range bars on a logarithmic scale comparing peak heat release rates of cars, buses, heavy goods vehicles and tankers from design tables and fire tests|Peak heat release rates of road vehicles: NFPA 502 (2008) design values and full-scale test results.]]&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;These numbers show why the load of an ordinary truck is the main uncertainty in a [[Tunnel fire]]. Unlike transit tunnels, where the operator controls vehicles and loads, a road tunnel admits any truck.&amp;lt;ref name=&amp;quot;Bendelius-21-189&amp;quot;&amp;gt;Bendelius (2008), p. 21-189.&amp;lt;/ref&amp;gt; An innocent-looking truck may carry a load that supports a fast-growing, potentially lethal fire without being classed as hazardous cargo. The incident truck in the Mont Blanc fire carried mainly margarine and flour, and other tunnel fires involved tyres, cheese, glue and rolls of plastic.&amp;lt;ref name=&amp;quot;Bendelius-21-191&amp;quot;&amp;gt;Bendelius (2008), pp. 21-190–21-191.&amp;lt;/ref&amp;gt; The wood floors of trailers and buses, in contrast, are relatively hard to ignite, burn slowly and matter only in very severe incidents.&amp;lt;ref name=&amp;quot;Routhier-21-20&amp;quot;&amp;gt;Routhier (2008), p. 21-20.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;These numbers show why the load of an ordinary truck is the main uncertainty in a [[Tunnel fire]]. Unlike transit tunnels, where the operator controls vehicles and loads, a road tunnel admits any truck.&amp;lt;ref name=&amp;quot;Bendelius-21-189&amp;quot;&amp;gt;Bendelius (2008), p. 21-189.&amp;lt;/ref&amp;gt; An innocent-looking truck may carry a load that supports a fast-growing, potentially lethal fire without being classed as hazardous cargo. The incident truck in the Mont Blanc fire carried mainly margarine and flour, and other tunnel fires involved tyres, cheese, glue and rolls of plastic.&amp;lt;ref name=&amp;quot;Bendelius-21-191&amp;quot;&amp;gt;Bendelius (2008), pp. 21-190–21-191.&amp;lt;/ref&amp;gt; The wood floors of trailers and buses, in contrast, are relatively hard to ignite, burn slowly and matter only in very severe incidents.&amp;lt;ref name=&amp;quot;Routhier-21-20&amp;quot;&amp;gt;Routhier (2008), p. 21-20.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l57&quot;&gt;Line 57:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 57:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;As a worked example, consider a diesel spill on a concrete surface that feeds a 20 MW fire, the size of the Memorial Tunnel bus or truck fire.&amp;lt;ref name=&amp;quot;Bendelius-21-208&amp;quot; /&amp;gt; With 390 kW/m² for unconfined diesel, the pool needs an area of 20,000/390 = 51.3 m².&amp;lt;ref name=&amp;quot;Budnick-3-149&amp;quot; /&amp;gt; At a depth of 2.8 mm, this pool holds only 51.3 × 0.0028 = 0.144 m³, or about 144 litres. With about 36 MJ per litre of diesel, the pool contains about 5,170 MJ.&amp;lt;ref name=&amp;quot;NIPV-25&amp;quot;&amp;gt;Van der Graaf et al. (2021/2023), p. 25.&amp;lt;/ref&amp;gt; Using unrounded values gives an estimated duration of about 258 s, or 4.3 minutes. Because both energy and burning rate scale with area, a thin unconfined film burns for about the same time whatever its size.&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;As a worked example, consider a diesel spill on a concrete surface that feeds a 20 MW fire, the size of the Memorial Tunnel bus or truck fire.&amp;lt;ref name=&amp;quot;Bendelius-21-208&amp;quot; /&amp;gt; With 390 kW/m² for unconfined diesel, the pool needs an area of 20,000/390 = 51.3 m².&amp;lt;ref name=&amp;quot;Budnick-3-149&amp;quot; /&amp;gt; At a depth of 2.8 mm, this pool holds only 51.3 × 0.0028 = 0.144 m³, or about 144 litres. With about 36 MJ per litre of diesel, the pool contains about 5,170 MJ.&amp;lt;ref name=&amp;quot;NIPV-25&amp;quot;&amp;gt;Van der Graaf et al. (2021/2023), p. 25.&amp;lt;/ref&amp;gt; Using unrounded values gives an estimated duration of about 258 s, or 4.3 minutes. Because both energy and burning rate scale with area, a thin unconfined film burns for about the same time whatever its size.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[[File:fse-commercial-vehicle-fire-v4.svg|thumb|upright=1.5|alt=Line chart of pool fire heat release rate against pool area for confined and unconfined diesel, with the worked example marked at 51 square metres and 20 MW|Heat release rate of diesel pool fires against pool area, confined and unconfined, with the worked example&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;. Based on Budnick et al. (2008), p. 3-149&lt;/del&gt;.]]&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[[File:fse-commercial-vehicle-fire-v4.svg|thumb|upright=1.5|alt=Line chart of pool fire heat release rate against pool area for confined and unconfined diesel, with the worked example marked at 51 square metres and 20 MW|Heat release rate of diesel pool fires against pool area, confined and unconfined, with the worked example.]]&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The example shows that a spill on its own can give an intense but short fire, while the long fires of heavy goods vehicles may be fed by cargo. For tankers the picture changes, because the load itself is liquid fuel. As an illustration, a 200–300 MW fire would require a confined petrol pool of about 83–125 m² at 2,400 kW/m²; this area is calculated from the pool-fire model, not specified by NFPA 502.&amp;lt;ref name=&amp;quot;Budnick-3-149&amp;quot; /&amp;gt; The tanker design fire in NFPA 502 assumes adequate drainage that limits the area and duration of the pool fire.&amp;lt;ref name=&amp;quot;Bendelius-21-204&amp;quot; /&amp;gt; The method has clear limits. It assumes a steady fire, and the source gives the 2.8 mm spill depth for concrete surfaces only.&amp;lt;ref name=&amp;quot;Budnick-3-149&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;Budnick-3-150&amp;quot;&amp;gt;Budnick et al. (2008), p. 3-150.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The example shows that a spill on its own can give an intense but short fire, while the long fires of heavy goods vehicles may be fed by cargo. For tankers the picture changes, because the load itself is liquid fuel. As an illustration, a 200–300 MW fire would require a confined petrol pool of about 83–125 m² at 2,400 kW/m²; this area is calculated from the pool-fire model, not specified by NFPA 502.&amp;lt;ref name=&amp;quot;Budnick-3-149&amp;quot; /&amp;gt; The tanker design fire in NFPA 502 assumes adequate drainage that limits the area and duration of the pool fire.&amp;lt;ref name=&amp;quot;Bendelius-21-204&amp;quot; /&amp;gt; The method has clear limits. It assumes a steady fire, and the source gives the 2.8 mm spill depth for concrete surfaces only.&amp;lt;ref name=&amp;quot;Budnick-3-149&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;Budnick-3-150&amp;quot;&amp;gt;Budnick et al. (2008), p. 3-150.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l65&quot;&gt;Line 65:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 65:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The 2008 handbook describes tank vehicles built to NFPA 385 and US Department of Transportation rules as able to withstand all but the most violent impacts without rupturing.&amp;lt;ref name=&amp;quot;Ordile-7-31&amp;quot;&amp;gt;Ordile (2008), p. 7-31.&amp;lt;/ref&amp;gt; Vents let vapour burn at the vent if the tank is exposed to fire, reducing the risk of rupture from internal pressure. For liquids other than viscous ones, a shutoff valve inside the tank shell stays closed except during loading and unloading. A shear section in the piping breaks in an accident and leaves this valve undamaged and closed. A remote control and a fusible element that operates at no more than 121 °C (250 °F) let the valve close in a fire.&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The 2008 handbook describes tank vehicles built to NFPA 385 and US Department of Transportation rules as able to withstand all but the most violent impacts without rupturing.&amp;lt;ref name=&amp;quot;Ordile-7-31&amp;quot;&amp;gt;Ordile (2008), p. 7-31.&amp;lt;/ref&amp;gt; Vents let vapour burn at the vent if the tank is exposed to fire, reducing the risk of rupture from internal pressure. For liquids other than viscous ones, a shutoff valve inside the tank shell stays closed except during loading and unloading. A shear section in the piping breaks in an accident and leaves this valve undamaged and closed. A remote control and a fusible element that operates at no more than 121 °C (250 °F) let the valve close in a fire.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[[File:fse-commercial-vehicle-fire-v3.svg|thumb|upright=1.5|alt=Cutaway side view of a tank trailer showing vent, internal shutoff valve, shear section, remote control and placard|Fire protection features of a cargo tank for flammable liquids&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;. Based on Ordile (2008), p. 7-31, and Routhier (2008), p. 21-27&lt;/del&gt;.]]&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[[File:fse-commercial-vehicle-fire-v3.svg|thumb|upright=1.5|alt=Cutaway side view of a tank trailer showing vent, internal shutoff valve, shear section, remote control and placard|Fire protection features of a cargo tank for flammable liquids.]]&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;For fire fighters, the main hazards are wrong or mixed loads, defective safety controls, large releases and a possible [[BLEVE]].&amp;lt;ref name=&amp;quot;Routhier-21-24&amp;quot; /&amp;gt; Missing or incorrect placards and shipping papers make the situation worse. Responders therefore approach from upwind, avoid contact with spilled material and first identify the product.&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;For fire fighters, the main hazards are wrong or mixed loads, defective safety controls, large releases and a possible [[BLEVE]].&amp;lt;ref name=&amp;quot;Routhier-21-24&amp;quot; /&amp;gt; Missing or incorrect placards and shipping papers make the situation worse. Responders therefore approach from upwind, avoid contact with spilled material and first identify the product.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;

&lt;!-- diff cache key firesb_pjbsiy42-wiki_:diff:1.41:old-5911:rev-6506:php=table --&gt;
&lt;/table&gt;</summary>
		<author><name>Mark</name></author>
	</entry>
	<entry>
		<id>https://fire-safety.academy/w/index.php?title=Commercial_vehicle_fire&amp;diff=5911&amp;oldid=prev</id>
		<title>Peter: Add SVG figures fse-commercial-vehicle-fire-v1.svg, fse-commercial-vehicle-fire-v2.svg, fse-commercial-vehicle-fire-v3.svg, fse-commercial-vehicle-fire-v4.svg (list-3 visual plan)</title>
		<link rel="alternate" type="text/html" href="https://fire-safety.academy/w/index.php?title=Commercial_vehicle_fire&amp;diff=5911&amp;oldid=prev"/>
		<updated>2026-11-12T12:21:01Z</updated>

		<summary type="html">&lt;p&gt;Add SVG figures fse-commercial-vehicle-fire-v1.svg, fse-commercial-vehicle-fire-v2.svg, fse-commercial-vehicle-fire-v3.svg, fse-commercial-vehicle-fire-v4.svg (list-3 visual plan)&lt;/p&gt;
&lt;table style=&quot;background-color: #fff; color: #202122;&quot; data-mw=&quot;interface&quot;&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;tr class=&quot;diff-title&quot; lang=&quot;en&quot;&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;← Older revision&lt;/td&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;Revision as of 13:21, 12 November 2026&lt;/td&gt;
				&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l23&quot;&gt;Line 23:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 23:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Tyres are a second typical source. If one tyre of a dual-tyre pair runs flat or is seriously underinflated, flexing can build up enough internal heat to ignite it.&amp;lt;ref name=&amp;quot;Routhier-21-22&amp;quot; /&amp;gt; Overloading, sustained high speed and high ambient temperatures add to this risk, and dual tyres spaced so closely that they rub can also ignite. Tyres can also be ignited by an overheated axle and then release a large amount of heat.&amp;lt;ref name=&amp;quot;Babrauskas-3-27&amp;quot;&amp;gt;Babrauskas (2002b), pp. 3-27–3-28.&amp;lt;/ref&amp;gt; The 2002 SFPE handbook cited one documented test: a burning pair of truck tyres in a tandem arrangement reached roughly 1 MW, read from its published curve.&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Tyres are a second typical source. If one tyre of a dual-tyre pair runs flat or is seriously underinflated, flexing can build up enough internal heat to ignite it.&amp;lt;ref name=&amp;quot;Routhier-21-22&amp;quot; /&amp;gt; Overloading, sustained high speed and high ambient temperatures add to this risk, and dual tyres spaced so closely that they rub can also ignite. Tyres can also be ignited by an overheated axle and then release a large amount of heat.&amp;lt;ref name=&amp;quot;Babrauskas-3-27&amp;quot;&amp;gt;Babrauskas (2002b), pp. 3-27–3-28.&amp;lt;/ref&amp;gt; The 2002 SFPE handbook cited one documented test: a burning pair of truck tyres in a tandem arrangement reached roughly 1 MW, read from its published curve.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-deleted&quot;&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;[[File:fse-commercial-vehicle-fire-v2.svg|thumb|upright=1.5|alt=Side view of a tractor-trailer with numbered callouts at brakes, dual tyres, axle, exhaust, fuel line, battery and cargo|Typical ignition sources on a heavy goods vehicle. Based on Routhier (2008), pp. 21-15–21-23, and Babrauskas (2002b), p. 3-27.]]&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The fuel and electrical systems are a third source. Diesel has a higher [[Flash point|flash point]] than petrol, but diesel engines run hotter, so fuel in the return line is warmer and more likely to ignite if it leaks onto a hot surface.&amp;lt;ref name=&amp;quot;Routhier-21-21&amp;quot;&amp;gt;Routhier (2008), p. 21-21.&amp;lt;/ref&amp;gt; A manual battery disconnect switch is desirable on buses and trucks, but such switches are rarely fitted. For buses, the great majority of fires are engine fires.&amp;lt;ref name=&amp;quot;Bukowski-5-228&amp;quot; /&amp;gt; Cargo can also be ignited by careless smoking during loading, which is why motor carriers generally prohibit it.&amp;lt;ref name=&amp;quot;Routhier-21-23&amp;quot;&amp;gt;Routhier (2008), p. 21-23.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The fuel and electrical systems are a third source. Diesel has a higher [[Flash point|flash point]] than petrol, but diesel engines run hotter, so fuel in the return line is warmer and more likely to ignite if it leaks onto a hot surface.&amp;lt;ref name=&amp;quot;Routhier-21-21&amp;quot;&amp;gt;Routhier (2008), p. 21-21.&amp;lt;/ref&amp;gt; A manual battery disconnect switch is desirable on buses and trucks, but such switches are rarely fitted. For buses, the great majority of fires are engine fires.&amp;lt;ref name=&amp;quot;Bukowski-5-228&amp;quot; /&amp;gt; Cargo can also be ignited by careless smoking during loading, which is why motor carriers generally prohibit it.&amp;lt;ref name=&amp;quot;Routhier-21-23&amp;quot;&amp;gt;Routhier (2008), p. 21-23.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l32&quot;&gt;Line 32:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 33:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;As summarised in the handbook, NFPA 502 (2008 edition) gives peaks of 20–30 MW for a bus, 70–200 MW for a heavy goods truck and 200–300 MW for a tanker.&amp;lt;ref name=&amp;quot;Bendelius-21-204&amp;quot; /&amp;gt; The peak may be reached within 10 minutes, and temperatures directly above the fire can reach 1,000 to 1,400 °C. In the Memorial Tunnel test programme of 1993–1995 in West Virginia, a 20 MW test fire represented a bus or truck, 50 MW a large truck and 100 MW a petrol tanker.&amp;lt;ref name=&amp;quot;Bendelius-21-208&amp;quot;&amp;gt;Bendelius (2008), p. 21-208.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;As summarised in the handbook, NFPA 502 (2008 edition) gives peaks of 20–30 MW for a bus, 70–200 MW for a heavy goods truck and 200–300 MW for a tanker.&amp;lt;ref name=&amp;quot;Bendelius-21-204&amp;quot; /&amp;gt; The peak may be reached within 10 minutes, and temperatures directly above the fire can reach 1,000 to 1,400 °C. In the Memorial Tunnel test programme of 1993–1995 in West Virginia, a 20 MW test fire represented a bus or truck, 50 MW a large truck and 100 MW a petrol tanker.&amp;lt;ref name=&amp;quot;Bendelius-21-208&amp;quot;&amp;gt;Bendelius (2008), p. 21-208.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-deleted&quot;&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;[[File:fse-commercial-vehicle-fire-v1.svg|thumb|upright=1.5|alt=Range bars on a logarithmic scale comparing peak heat release rates of cars, buses, heavy goods vehicles and tankers from design tables and fire tests|Peak heat release rates of road vehicles: NFPA 502 (2008) design values and full-scale test results. Based on Bendelius (2008), p. 21-204, Mawhinney (2008), p. 16-140, and Babrauskas (2002b), pp. 3-27–3-28.]]&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;These numbers show why the load of an ordinary truck is the main uncertainty in a [[Tunnel fire]]. Unlike transit tunnels, where the operator controls vehicles and loads, a road tunnel admits any truck.&amp;lt;ref name=&amp;quot;Bendelius-21-189&amp;quot;&amp;gt;Bendelius (2008), p. 21-189.&amp;lt;/ref&amp;gt; An innocent-looking truck may carry a load that supports a fast-growing, potentially lethal fire without being classed as hazardous cargo. The incident truck in the Mont Blanc fire carried mainly margarine and flour, and other tunnel fires involved tyres, cheese, glue and rolls of plastic.&amp;lt;ref name=&amp;quot;Bendelius-21-191&amp;quot;&amp;gt;Bendelius (2008), pp. 21-190–21-191.&amp;lt;/ref&amp;gt; The wood floors of trailers and buses, in contrast, are relatively hard to ignite, burn slowly and matter only in very severe incidents.&amp;lt;ref name=&amp;quot;Routhier-21-20&amp;quot;&amp;gt;Routhier (2008), p. 21-20.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;These numbers show why the load of an ordinary truck is the main uncertainty in a [[Tunnel fire]]. Unlike transit tunnels, where the operator controls vehicles and loads, a road tunnel admits any truck.&amp;lt;ref name=&amp;quot;Bendelius-21-189&amp;quot;&amp;gt;Bendelius (2008), p. 21-189.&amp;lt;/ref&amp;gt; An innocent-looking truck may carry a load that supports a fast-growing, potentially lethal fire without being classed as hazardous cargo. The incident truck in the Mont Blanc fire carried mainly margarine and flour, and other tunnel fires involved tyres, cheese, glue and rolls of plastic.&amp;lt;ref name=&amp;quot;Bendelius-21-191&amp;quot;&amp;gt;Bendelius (2008), pp. 21-190–21-191.&amp;lt;/ref&amp;gt; The wood floors of trailers and buses, in contrast, are relatively hard to ignite, burn slowly and matter only in very severe incidents.&amp;lt;ref name=&amp;quot;Routhier-21-20&amp;quot;&amp;gt;Routhier (2008), p. 21-20.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l55&quot;&gt;Line 55:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 57:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;As a worked example, consider a diesel spill on a concrete surface that feeds a 20 MW fire, the size of the Memorial Tunnel bus or truck fire.&amp;lt;ref name=&amp;quot;Bendelius-21-208&amp;quot; /&amp;gt; With 390 kW/m² for unconfined diesel, the pool needs an area of 20,000/390 = 51.3 m².&amp;lt;ref name=&amp;quot;Budnick-3-149&amp;quot; /&amp;gt; At a depth of 2.8 mm, this pool holds only 51.3 × 0.0028 = 0.144 m³, or about 144 litres. With about 36 MJ per litre of diesel, the pool contains about 5,170 MJ.&amp;lt;ref name=&amp;quot;NIPV-25&amp;quot;&amp;gt;Van der Graaf et al. (2021/2023), p. 25.&amp;lt;/ref&amp;gt; Using unrounded values gives an estimated duration of about 258 s, or 4.3 minutes. Because both energy and burning rate scale with area, a thin unconfined film burns for about the same time whatever its size.&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;As a worked example, consider a diesel spill on a concrete surface that feeds a 20 MW fire, the size of the Memorial Tunnel bus or truck fire.&amp;lt;ref name=&amp;quot;Bendelius-21-208&amp;quot; /&amp;gt; With 390 kW/m² for unconfined diesel, the pool needs an area of 20,000/390 = 51.3 m².&amp;lt;ref name=&amp;quot;Budnick-3-149&amp;quot; /&amp;gt; At a depth of 2.8 mm, this pool holds only 51.3 × 0.0028 = 0.144 m³, or about 144 litres. With about 36 MJ per litre of diesel, the pool contains about 5,170 MJ.&amp;lt;ref name=&amp;quot;NIPV-25&amp;quot;&amp;gt;Van der Graaf et al. (2021/2023), p. 25.&amp;lt;/ref&amp;gt; Using unrounded values gives an estimated duration of about 258 s, or 4.3 minutes. Because both energy and burning rate scale with area, a thin unconfined film burns for about the same time whatever its size.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-deleted&quot;&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;[[File:fse-commercial-vehicle-fire-v4.svg|thumb|upright=1.5|alt=Line chart of pool fire heat release rate against pool area for confined and unconfined diesel, with the worked example marked at 51 square metres and 20 MW|Heat release rate of diesel pool fires against pool area, confined and unconfined, with the worked example. Based on Budnick et al. (2008), p. 3-149.]]&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The example shows that a spill on its own can give an intense but short fire, while the long fires of heavy goods vehicles may be fed by cargo. For tankers the picture changes, because the load itself is liquid fuel. As an illustration, a 200–300 MW fire would require a confined petrol pool of about 83–125 m² at 2,400 kW/m²; this area is calculated from the pool-fire model, not specified by NFPA 502.&amp;lt;ref name=&amp;quot;Budnick-3-149&amp;quot; /&amp;gt; The tanker design fire in NFPA 502 assumes adequate drainage that limits the area and duration of the pool fire.&amp;lt;ref name=&amp;quot;Bendelius-21-204&amp;quot; /&amp;gt; The method has clear limits. It assumes a steady fire, and the source gives the 2.8 mm spill depth for concrete surfaces only.&amp;lt;ref name=&amp;quot;Budnick-3-149&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;Budnick-3-150&amp;quot;&amp;gt;Budnick et al. (2008), p. 3-150.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The example shows that a spill on its own can give an intense but short fire, while the long fires of heavy goods vehicles may be fed by cargo. For tankers the picture changes, because the load itself is liquid fuel. As an illustration, a 200–300 MW fire would require a confined petrol pool of about 83–125 m² at 2,400 kW/m²; this area is calculated from the pool-fire model, not specified by NFPA 502.&amp;lt;ref name=&amp;quot;Budnick-3-149&amp;quot; /&amp;gt; The tanker design fire in NFPA 502 assumes adequate drainage that limits the area and duration of the pool fire.&amp;lt;ref name=&amp;quot;Bendelius-21-204&amp;quot; /&amp;gt; The method has clear limits. It assumes a steady fire, and the source gives the 2.8 mm spill depth for concrete surfaces only.&amp;lt;ref name=&amp;quot;Budnick-3-149&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;Budnick-3-150&amp;quot;&amp;gt;Budnick et al. (2008), p. 3-150.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l62&quot;&gt;Line 62:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 65:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The 2008 handbook describes tank vehicles built to NFPA 385 and US Department of Transportation rules as able to withstand all but the most violent impacts without rupturing.&amp;lt;ref name=&amp;quot;Ordile-7-31&amp;quot;&amp;gt;Ordile (2008), p. 7-31.&amp;lt;/ref&amp;gt; Vents let vapour burn at the vent if the tank is exposed to fire, reducing the risk of rupture from internal pressure. For liquids other than viscous ones, a shutoff valve inside the tank shell stays closed except during loading and unloading. A shear section in the piping breaks in an accident and leaves this valve undamaged and closed. A remote control and a fusible element that operates at no more than 121 °C (250 °F) let the valve close in a fire.&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The 2008 handbook describes tank vehicles built to NFPA 385 and US Department of Transportation rules as able to withstand all but the most violent impacts without rupturing.&amp;lt;ref name=&amp;quot;Ordile-7-31&amp;quot;&amp;gt;Ordile (2008), p. 7-31.&amp;lt;/ref&amp;gt; Vents let vapour burn at the vent if the tank is exposed to fire, reducing the risk of rupture from internal pressure. For liquids other than viscous ones, a shutoff valve inside the tank shell stays closed except during loading and unloading. A shear section in the piping breaks in an accident and leaves this valve undamaged and closed. A remote control and a fusible element that operates at no more than 121 °C (250 °F) let the valve close in a fire.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-deleted&quot;&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;[[File:fse-commercial-vehicle-fire-v3.svg|thumb|upright=1.5|alt=Cutaway side view of a tank trailer showing vent, internal shutoff valve, shear section, remote control and placard|Fire protection features of a cargo tank for flammable liquids. Based on Ordile (2008), p. 7-31, and Routhier (2008), p. 21-27.]]&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;For fire fighters, the main hazards are wrong or mixed loads, defective safety controls, large releases and a possible [[BLEVE]].&amp;lt;ref name=&amp;quot;Routhier-21-24&amp;quot; /&amp;gt; Missing or incorrect placards and shipping papers make the situation worse. Responders therefore approach from upwind, avoid contact with spilled material and first identify the product.&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;For fire fighters, the main hazards are wrong or mixed loads, defective safety controls, large releases and a possible [[BLEVE]].&amp;lt;ref name=&amp;quot;Routhier-21-24&amp;quot; /&amp;gt; Missing or incorrect placards and shipping papers make the situation worse. Responders therefore approach from upwind, avoid contact with spilled material and first identify the product.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;

&lt;!-- diff cache key firesb_pjbsiy42-wiki_:diff:1.41:old-4257:rev-5911:php=table --&gt;
&lt;/table&gt;</summary>
		<author><name>Peter</name></author>
	</entry>
	<entry>
		<id>https://fire-safety.academy/w/index.php?title=Commercial_vehicle_fire&amp;diff=4257&amp;oldid=prev</id>
		<title>Mark: FSE wiki: fact-check: correct historical statistics, design-fire scope and tank safeguards (written by Claude Opus 5.5)</title>
		<link rel="alternate" type="text/html" href="https://fire-safety.academy/w/index.php?title=Commercial_vehicle_fire&amp;diff=4257&amp;oldid=prev"/>
		<updated>2026-11-08T01:14:32Z</updated>

		<summary type="html">&lt;p&gt;FSE wiki: fact-check: correct historical statistics, design-fire scope and tank safeguards (written by Claude Opus 5.5)&lt;/p&gt;
&lt;a href=&quot;https://fire-safety.academy/w/index.php?title=Commercial_vehicle_fire&amp;amp;diff=4257&amp;amp;oldid=3274&quot;&gt;Show changes&lt;/a&gt;</summary>
		<author><name>Mark</name></author>
	</entry>
	<entry>
		<id>https://fire-safety.academy/w/index.php?title=Commercial_vehicle_fire&amp;diff=3274&amp;oldid=prev</id>
		<title>Mark: New FSE wiki article: Commercial vehicle fire (written by Claude Opus 5.5)</title>
		<link rel="alternate" type="text/html" href="https://fire-safety.academy/w/index.php?title=Commercial_vehicle_fire&amp;diff=3274&amp;oldid=prev"/>
		<updated>2026-11-07T21:17:45Z</updated>

		<summary type="html">&lt;p&gt;New FSE wiki article: Commercial vehicle fire (written by Claude Opus 5.5)&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;A &amp;#039;&amp;#039;&amp;#039;commercial vehicle fire&amp;#039;&amp;#039;&amp;#039; is a fire in a motor vehicle used in business to carry goods or passengers, such as a truck, tractor-trailer, tank truck, delivery van or bus. It shares the basic hazards of every [[Motor vehicle fire|motor vehicle fire]]: flammable fuel, hot engine and exhaust parts, electrical wiring and combustible trim.&amp;lt;ref name=&amp;quot;Routhier-21-15&amp;quot;&amp;gt;Routhier (2008), p. 21-15.&amp;lt;/ref&amp;gt; What sets it apart is the load. Trucks may carry cargo that is flammable, and tank trucks and other bulk vehicles may carry hazardous materials whose release turns a vehicle fire into a hazardous materials incident.&amp;lt;ref name=&amp;quot;Routhier-21-16&amp;quot;&amp;gt;Routhier (2008), p. 21-16.&amp;lt;/ref&amp;gt; Heavy vehicles also bring their own ignition sources, such as overheated brakes and dual tyres.&lt;br /&gt;
&lt;br /&gt;
A heavy goods truck can burn far more intensely than a car: road tunnel design fires for such trucks range from 70 to 200 MW, against 5–10 MW for a passenger car.&amp;lt;ref name=&amp;quot;Bendelius-21-204&amp;quot;&amp;gt;Bendelius (2008), p. 21-204.&amp;lt;/ref&amp;gt; The road tunnel fires at Mont Blanc and in the Tauern Tunnel in 1999 killed 51 people and destroyed 34 trucks and tractor-trailers.&amp;lt;ref name=&amp;quot;Bendelius-21-190&amp;quot;&amp;gt;Bendelius (2008), pp. 21-189–21-190.&amp;lt;/ref&amp;gt; In the United States, commercial vehicles in use fall under the Federal Motor Carrier Safety Regulations, which require fire extinguishers, fuelling precautions and special rules for vehicles carrying hazardous materials.&amp;lt;ref name=&amp;quot;Routhier-21-18&amp;quot;&amp;gt;Routhier (2008), p. 21-18.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== Definition and regulatory scope ==&lt;br /&gt;
The fire hazard of a commercial vehicle depends on the vehicle type, its use in commercial service, its age and maintenance, its fuel and the way that fuel is stored on board.&amp;lt;ref name=&amp;quot;Routhier-21-15&amp;quot; /&amp;gt; The materials carried as cargo, such as upholstery, plastic, wood, fuel and hazardous materials, are a further factor. The fuel may be diesel, petrol, propane, natural gas or alcohol.&lt;br /&gt;
&lt;br /&gt;
In the United States, two sets of federal rules apply. The Federal Motor Vehicle Safety Standards (FMVSS) of the National Highway Traffic Safety Administration apply to new vehicles.&amp;lt;ref name=&amp;quot;Routhier-21-17&amp;quot;&amp;gt;Routhier (2008), p. 21-17.&amp;lt;/ref&amp;gt; The Federal Motor Carrier Safety Regulations (FMCSRs), administered by the Federal Motor Carrier Safety Administration (FMCSA), apply to vehicles in use.&amp;lt;ref name=&amp;quot;Routhier-21-18&amp;quot; /&amp;gt; These regulations, in Title 49 of the Code of Federal Regulations, Parts 325–399, cover commercial vehicles in interstate or foreign commerce. Because most states have adopted them by reference, they also apply to most commercial vehicles that travel only within one state.&lt;br /&gt;
&lt;br /&gt;
Several of the fuel system rules for light vehicles stop at a gross vehicle weight rating of 4,536 kg (10,000 lb). The FMVSS 301 crash tests for fuel leakage apply to cars, trucks and buses up to that weight.&amp;lt;ref name=&amp;quot;Routhier-21-17&amp;quot; /&amp;gt; School buses above 4,536 kg are also covered, with a special moving barrier that strikes the bus at the front, rear and sides. Hazardous materials rules apply to both interstate and intrastate transport and are published in 49 CFR Parts 105–180.&amp;lt;ref name=&amp;quot;Routhier-21-18&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== Fire problem and major incidents ==&lt;br /&gt;
The US fire statistics in the source documents do not separate trucks and buses from cars. In 2000, there were an estimated 325,000 fires in highway vehicles, causing 450 civilian deaths and 1,325 civilian injuries.&amp;lt;ref name=&amp;quot;Routhier-21-15&amp;quot; /&amp;gt; In 1999–2003, fires in the cargo or trunk area made up 3% of all highway vehicle fires and 7% of the civilian injuries.&amp;lt;ref name=&amp;quot;Routhier-21-17&amp;quot; /&amp;gt; More detailed analyses of truck fires by the FMCSA were described in 2008 as dated.&amp;lt;ref name=&amp;quot;Routhier-21-16&amp;quot; /&amp;gt; Death and injury result from direct exposure to heat and from breathing toxic combustion products, sometimes because jammed doors or seats prevent escape.&amp;lt;ref name=&amp;quot;Routhier-21-16&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Hazardous cargo makes some commercial vehicle fires far more severe. The National Transportation Safety Board, the FMCSA and NFPA investigated many crashes in which hazardous materials exploded or burned.&amp;lt;ref name=&amp;quot;Routhier-21-16&amp;quot; /&amp;gt; These investigations led to changes in the rules for hazardous materials containers, but such cargo fires and explosions still occur. Fires on or under bridges can also damage the structure. In 1998, a tank truck carrying 33,000 litres of petrol jumped a barrier on Interstate 95 in Pennsylvania and exploded, killing both drivers involved.&amp;lt;ref name=&amp;quot;Bendelius-21-210&amp;quot;&amp;gt;Bendelius (2008), p. 21-210.&amp;lt;/ref&amp;gt; In 2004, a tank truck carrying 45,500 litres of fuel oil burned on the same highway in Connecticut, and the fire melted steel support beams of a bridge.&lt;br /&gt;
&lt;br /&gt;
The deadliest examples are fires in long road tunnels. In the Mont Blanc Tunnel between France and Italy in March 1999, 39 people died and 34 vehicles were destroyed, including 20 tractor-trailers.&amp;lt;ref name=&amp;quot;Bendelius-21-190&amp;quot; /&amp;gt; In the Austrian Tauern Tunnel in May 1999, 12 people died and 14 trucks and 20 cars were destroyed. In the Swiss St. Gotthard Tunnel in October 2001, 8 people died and 13 trucks and 10 cars were destroyed.&lt;br /&gt;
&lt;br /&gt;
Bus fires can also kill many people at once. In a 1988 crash in Kentucky, a pickup truck struck a church bus, and the following fire killed 27 people.&amp;lt;ref name=&amp;quot;Bukowski-5-228&amp;quot;&amp;gt;Bukowski (2002), p. 5-228.&amp;lt;/ref&amp;gt; Fuel leaking from the bus tank burned through cracks in the floor, the crash destroyed the front door, and luggage blocked the rear emergency exit.&lt;br /&gt;
&lt;br /&gt;
== Causes and ignition sources ==&lt;br /&gt;
Heavy vehicles share the ignition sources of all motor vehicles: electrical faults, hot exhaust parts, engine backfire and friction sparks from a collision.&amp;lt;ref name=&amp;quot;Routhier-21-15&amp;quot; /&amp;gt; Some sources, however, grow with the size and weight of the vehicle. Overused brakes can overheat until they smoulder or burn, and this problem increases with the size and gross weight of the vehicle.&amp;lt;ref name=&amp;quot;Routhier-21-22&amp;quot;&amp;gt;Routhier (2008), p. 21-22.&amp;lt;/ref&amp;gt; On long downgrades, drivers rely mainly on engine braking in a low gear, and engine braking devices are used on diesel trucks, especially in mountainous regions.&lt;br /&gt;
&lt;br /&gt;
Tyres are a second typical source. If one tyre of a dual-tyre pair runs flat or is seriously underinflated, flexing can build up enough internal heat to ignite it.&amp;lt;ref name=&amp;quot;Routhier-21-22&amp;quot; /&amp;gt; Overloading, sustained high speed and high ambient temperatures add to this risk, and dual tyres spaced so closely that they rub can also ignite. Tyres can also be ignited by an overheated axle and then release a large amount of heat.&amp;lt;ref name=&amp;quot;Babrauskas-3-27&amp;quot;&amp;gt;Babrauskas (2002b), pp. 3-27–3-28.&amp;lt;/ref&amp;gt; In the only documented test, a burning pair of truck tyres in a tandem arrangement reached roughly 1 MW, read from the published curve.&lt;br /&gt;
&lt;br /&gt;
The fuel and electrical systems are a third source. Diesel has a higher [[Flash point|flash point]] than petrol, but diesel engines run hotter, so fuel in the return line is warmer and more likely to ignite if it leaks onto a hot surface.&amp;lt;ref name=&amp;quot;Routhier-21-21&amp;quot;&amp;gt;Routhier (2008), p. 21-21.&amp;lt;/ref&amp;gt; A manual battery disconnect switch is desirable on buses and trucks, but such switches are rarely fitted. For buses, the great majority of fires are engine fires.&amp;lt;ref name=&amp;quot;Bukowski-5-228&amp;quot; /&amp;gt; Cargo can also be ignited by careless smoking during loading, which is why motor carriers generally prohibit it.&amp;lt;ref name=&amp;quot;Routhier-21-23&amp;quot;&amp;gt;Routhier (2008), p. 21-23.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== Heat release rate and fire load ==&lt;br /&gt;
The cargo can dominate the [[Heat release rate|heat release rate]] of a burning truck. A European test programme burned nearly two dozen vehicles, including cars, buses, trams, trucks and rail vehicles.&amp;lt;ref name=&amp;quot;Babrauskas-3-27&amp;quot; /&amp;gt; Many of these fires peaked at about 10–35 MW, and in the published curve a school bus peaked just below 35 MW after about 15 minutes. A truck loaded with 2 tonnes of modern upholstered furniture, however, peaked at about 120 MW. An unloaded truck has a [[Fire load|fire load]] of about 19,000 MJ, two to three times the 6,000 to 12,000 MJ of a passenger car.&amp;lt;ref name=&amp;quot;VR-4.4&amp;quot;&amp;gt;Van Rossum (2027), §4.4.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Full-scale tests in the Runehamar Tunnel in Norway in 2003 confirmed these large values. A typical heavy goods vehicle carrying furniture or foam mattresses produced a fire of 75 to 200 MW.&amp;lt;ref name=&amp;quot;Mawhinney-16-140&amp;quot;&amp;gt;Mawhinney (2008), p. 16-140.&amp;lt;/ref&amp;gt; At the time, NFPA 502, the US standard for road tunnels, suggested a design fire of 30 MW for such a vehicle. Ventilation designed for 30 MW cannot cope with a fire of 150 MW, a fivefold underestimate.&lt;br /&gt;
&lt;br /&gt;
As summarised in the handbook, NFPA 502 (2008 edition) gives peaks of 20–30 MW for a bus, 70–200 MW for a heavy goods truck and 200–300 MW for a tanker.&amp;lt;ref name=&amp;quot;Bendelius-21-204&amp;quot; /&amp;gt; The peak may be reached within 10 minutes, and temperatures directly above the fire can reach 1,000 to 1,400 °C. In the Memorial Tunnel test programme of 1993–1995 in West Virginia, a 20 MW test fire represented a bus or truck, 50 MW a large truck and 100 MW a petrol tanker.&amp;lt;ref name=&amp;quot;Bendelius-21-208&amp;quot;&amp;gt;Bendelius (2008), p. 21-208.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
These numbers show why the load of an ordinary truck is the main uncertainty in a [[Tunnel fire]]. Unlike transit tunnels, where the operator controls vehicles and loads, a road tunnel admits any truck.&amp;lt;ref name=&amp;quot;Bendelius-21-189&amp;quot;&amp;gt;Bendelius (2008), p. 21-189.&amp;lt;/ref&amp;gt; An innocent-looking truck may carry a load that supports a fast-growing, potentially lethal fire without being classed as hazardous cargo. The incident truck in the Mont Blanc fire carried mainly margarine and flour, and other tunnel fires involved tyres, cheese, glue and rolls of plastic.&amp;lt;ref name=&amp;quot;Bendelius-21-191&amp;quot;&amp;gt;Bendelius (2008), pp. 21-190–21-191.&amp;lt;/ref&amp;gt; The wood floors of trailers and buses, in contrast, are relatively hard to ignite, burn slowly and matter only in very severe incidents.&amp;lt;ref name=&amp;quot;Routhier-21-20&amp;quot;&amp;gt;Routhier (2008), p. 21-20.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== Fuel spills and pool fires ==&lt;br /&gt;
When fuel or a liquid cargo escapes, it forms a [[Pool fire|pool fire]], whose power is set by the size of the pool rather than by the vehicle materials.&amp;lt;ref name=&amp;quot;Long-21-9&amp;quot;&amp;gt;Long et al. (2008), p. 21-9.&amp;lt;/ref&amp;gt; The heat release rate equals the burning rate per unit area of the liquid times the area of the pool.&amp;lt;ref name=&amp;quot;Budnick-3-149&amp;quot;&amp;gt;Budnick et al. (2008), p. 3-149.&amp;lt;/ref&amp;gt; The duration equals the energy in the fuel divided by the heat release rate. A spill that spreads freely on a hard surface burns at about one fifth of the rate per unit area of a deep, confined pool, because heat is lost to the ground beneath. On concrete, such an unconfined spill is about 2.8 mm deep or less.&lt;br /&gt;
&lt;br /&gt;
&amp;lt;math display=&amp;quot;block&amp;quot;&amp;gt;\dot{Q} = \dot{q}&amp;#039;&amp;#039;A \qquad t_{FD} = \frac{M\,\Delta H_c}{\dot{Q}}&amp;lt;/math&amp;gt;&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
! Symbol !! Description !! Unit&lt;br /&gt;
|-&lt;br /&gt;
| &amp;lt;math&amp;gt;\dot{Q}&amp;lt;/math&amp;gt; || Heat release rate of the pool fire || kW&lt;br /&gt;
|-&lt;br /&gt;
| &amp;lt;math&amp;gt;\dot{q}&amp;#039;&amp;#039;&amp;lt;/math&amp;gt; || Heat release rate per unit area (diesel: 1,950 confined, 390 unconfined) || kW/m²&lt;br /&gt;
|-&lt;br /&gt;
| &amp;lt;math&amp;gt;A&amp;lt;/math&amp;gt; || Area of the burning pool || m²&lt;br /&gt;
|-&lt;br /&gt;
| &amp;lt;math&amp;gt;t_{FD}&amp;lt;/math&amp;gt; || Fire duration || s&lt;br /&gt;
|-&lt;br /&gt;
| &amp;lt;math&amp;gt;M\,\Delta H_c&amp;lt;/math&amp;gt; || Energy in the fuel: mass times heat of combustion, or volume times energy per litre || kJ&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
As a worked example, consider a diesel spill on a concrete surface that feeds a 20 MW fire, the size of the Memorial Tunnel bus or truck fire.&amp;lt;ref name=&amp;quot;Bendelius-21-208&amp;quot; /&amp;gt; With 390 kW/m² for unconfined diesel, the pool needs an area of 20,000/390 = 51.3 m².&amp;lt;ref name=&amp;quot;Budnick-3-149&amp;quot; /&amp;gt; At a depth of 2.8 mm, this pool holds only 51.3 × 0.0028 = 0.144 m³, or about 144 litres. With about 36 MJ per litre of diesel, the pool contains about 5,170 MJ.&amp;lt;ref name=&amp;quot;NIPV-25&amp;quot;&amp;gt;Van der Graaf et al. (2021/2023), p. 25.&amp;lt;/ref&amp;gt; The fire therefore lasts 5,170,000/20,000 = 258 s, or about 4 minutes. Because both energy and burning rate scale with area, a thin unconfined film burns for about the same time whatever its size.&lt;br /&gt;
&lt;br /&gt;
The example shows that a spill on its own gives an intense but short fire, while the long fires of heavy goods vehicles are fed by the cargo. For tankers the picture changes, because the load itself is liquid fuel. A 200–300 MW tanker design fire corresponds to a confined petrol pool of about 83–125 m², using 2,400 kW/m² for confined petrol.&amp;lt;ref name=&amp;quot;Budnick-3-149&amp;quot; /&amp;gt; The tanker design fire in NFPA 502 assumes adequate drainage that limits the area and duration of the pool fire.&amp;lt;ref name=&amp;quot;Bendelius-21-204&amp;quot; /&amp;gt; The method has clear limits. It assumes a steady fire, and the source gives the 2.8 mm spill depth for concrete surfaces only.&amp;lt;ref name=&amp;quot;Budnick-3-149&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;Budnick-3-150&amp;quot;&amp;gt;Budnick et al. (2008), p. 3-150.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== Cargo tanks and hazardous materials ==&lt;br /&gt;
A [[Cargo tank vehicle]], also called a tank truck or tank motor vehicle, is the most common vehicle for moving flammable, combustible and corrosive liquids and compressed gases by road.&amp;lt;ref name=&amp;quot;Routhier-21-23&amp;quot; /&amp;gt; When such a tank is involved in an accident, the disaster potential is substantial. Leakage can occur in both contact and non-contact accidents, and the main causes of unintentional release are poor maintenance and deviation from tank specifications.&amp;lt;ref name=&amp;quot;Routhier-21-24&amp;quot;&amp;gt;Routhier (2008), p. 21-24.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Tank vehicles built to NFPA 385 and US Department of Transportation rules are designed to withstand all but the most violent impacts without rupturing.&amp;lt;ref name=&amp;quot;Ordile-7-31&amp;quot;&amp;gt;Ordile (2008), p. 7-31.&amp;lt;/ref&amp;gt; Vents let vapour burn at the vent if the tank is exposed to fire, so that the tank does not rupture from internal pressure. For most liquids, a shutoff valve inside the tank shell stays closed except during loading and unloading. A shear section in the piping breaks in an accident and leaves this valve undamaged and closed. A remote control and a fusible element that operates at no more than 121 °C (250 °F) let the valve close in a fire.&lt;br /&gt;
&lt;br /&gt;
For fire fighters, the main hazards are wrong or mixed loads, defective safety controls, large releases and a possible [[BLEVE]].&amp;lt;ref name=&amp;quot;Routhier-21-24&amp;quot; /&amp;gt; Missing or incorrect placards and shipping papers make the situation worse. Responders therefore approach from upwind, avoid contact with spilled material and first identify the product.&lt;br /&gt;
&lt;br /&gt;
[[Hazardous materials placarding]] gives this information on the outside of the vehicle. In the United States, placards of 273 mm by 273 mm (10.8 in.) are required on bulk packages such as cargo tanks.&amp;lt;ref name=&amp;quot;Wright-13-124&amp;quot;&amp;gt;C. J. Wright (2008a), p. 13-124.&amp;lt;/ref&amp;gt; They show the hazard class by colour, symbol and number, together with either the class name or a four-digit identification number. Up to 454 kg (1,000 lb) of certain hazardous materials may be carried without a placard, so a vehicle without placards may still carry some hazardous materials.&lt;br /&gt;
&lt;br /&gt;
== Vehicle design and on-board protection ==&lt;br /&gt;
FMCSA fuel tank rules for commercial vehicles closely follow UL standards, and since 1973 they have also applied to diesel tanks.&amp;lt;ref name=&amp;quot;Routhier-21-21&amp;quot; /&amp;gt; Tanks must pass drop, rupture, vent and spillage tests, and the safety vent must limit the pressure rise to 345 kPa (50 psig) in a specified fire test. No FMVSS, NHTSA or FMCSA standard sets fire retardance requirements for cargo trailers or truck bodies.&amp;lt;ref name=&amp;quot;Routhier-21-20&amp;quot; /&amp;gt; The FMCSRs do require flooring in good condition and prohibit floors soaked with oil or petrol.&lt;br /&gt;
&lt;br /&gt;
Commercial vehicles in interstate commerce must carry fire extinguishers under the FMCSRs, and the driver must check the extinguisher at the start of each trip.&amp;lt;ref name=&amp;quot;Routhier-21-18&amp;quot; /&amp;gt; A power unit that does not carry placarded hazardous materials needs a 5-B:C extinguisher or two 4-B:C extinguishers.&amp;lt;ref name=&amp;quot;Routhier-21-22&amp;quot; /&amp;gt; A power unit carrying hazardous materials needs a 10-B:C extinguisher. The [[Fire extinguisher rating]] B:C means the unit is suitable for flammable liquid fires and fires in energised electrical equipment.&amp;lt;ref name=&amp;quot;Rivkin-21-38&amp;quot;&amp;gt;Rivkin (2008a), p. 21-38.&amp;lt;/ref&amp;gt; The number indicates its relative extinguishing power.&lt;br /&gt;
&lt;br /&gt;
Buses are covered by only a few fire safety requirements in the United States.&amp;lt;ref name=&amp;quot;Bukowski-5-228&amp;quot; /&amp;gt; These are the FMVSS 302 limits on interior linings and seats, a fire-resistive barrier around the engine compartment and protection of the fuel tank against penetration. The barrier gives the driver time to stop the bus and let the passengers out, and some buses also have fixed extinguishing systems in the engine compartment.&lt;br /&gt;
&lt;br /&gt;
The FMVSS 302 test exposes a horizontal sample to a 38 mm Bunsen flame for 15 seconds and limits the burn rate to 100 mm per minute.&amp;lt;ref name=&amp;quot;Stull-6-98&amp;quot;&amp;gt;Stull and Chines (2008), p. 6-98.&amp;lt;/ref&amp;gt; It provides only minimum protection, and in 2008 work was in progress on a more realistic test, especially for school buses. Extra padding on school bus seats protects occupants in a crash, but it also adds fuel. In a hazard assessment based on bench-scale and full-scale tests, two seat assemblies produced incapacitating conditions within 3 minutes, while three others did not produce untenable conditions.&amp;lt;ref name=&amp;quot;Bukowski-5-228&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
New drive systems add new hazards. Vehicles that run on liquefied petroleum gas range from cars to heavy-duty trucks.&amp;lt;ref name=&amp;quot;Rivkin-21-72&amp;quot;&amp;gt;Rivkin (2008b), p. 21-72.&amp;lt;/ref&amp;gt; Under NFPA 58, as summarised in 2008, buses may carry containers with a total water capacity of no more than 0.75 m³, against 1.1 m³ for vehicles not designed to carry passengers. Battery systems for trucks store 10 to 400 kWh, and in 2021 chargers of 600 kW already existed for buses and trucks.&amp;lt;ref name=&amp;quot;NIPV-21&amp;quot;&amp;gt;Van der Graaf et al. (2021/2023), pp. 12, 21.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== Fire response ==&lt;br /&gt;
The first steps are the same as for any vehicle fire. The engine and electrical systems are shut off, everyone moves well away, preferably uphill and upwind, the fire department is called, and the fire is fought only if this is safe.&amp;lt;ref name=&amp;quot;Routhier-21-22&amp;quot; /&amp;gt; If a combination vehicle is involved, the power unit is unhooked and moved away from the fire, if this can be done safely.&amp;lt;ref name=&amp;quot;Routhier-21-23&amp;quot; /&amp;gt; A burning flammable gas is left to burn until the leak is controlled, while a container exposed to flames is kept cool. If no hose streams are available, the handbook advises running away immediately.&lt;br /&gt;
&lt;br /&gt;
Two cases need special care. A tyre fire results from internal heat build-up, so portable extinguishers can only control the open flames, and large quantities of water are needed to cool the tyre.&amp;lt;ref name=&amp;quot;Routhier-21-23&amp;quot; /&amp;gt; A hot tyre is moved well away from the vehicle, or the driver waits until it is cool, because it may burst into flames and destroy the vehicle and its load. If smoke seeps from a closed van body, the doors stay closed until the fire department arrives. Opening them lets in oxygen and may cause a sudden flare-up.&lt;br /&gt;
&lt;br /&gt;
In European road tunnels, fixed suppression has gained ground since the Runehamar tests. These tests suggested that water-based suppression is in fact necessary to reduce the impact of heavy goods vehicle fires to a level that ventilation can handle.&amp;lt;ref name=&amp;quot;Mawhinney-16-140&amp;quot; /&amp;gt; A [[Water mist system|water mist system]] cools the gases, prevents spread beyond the first one or two vehicles and reduces the buoyant spread of smoke. It does not, however, clean the smoke: visibility does not improve enough and carbon monoxide is not removed. Full-scale tests have shown that water mist can protect life and property even against catastrophic heavy goods vehicle fires.&amp;lt;ref name=&amp;quot;Mawhinney-16-141&amp;quot;&amp;gt;Mawhinney (2008), p. 16-141.&amp;lt;/ref&amp;gt; In the Memorial Tunnel tests, a foam system with 3% aqueous film-forming foam put out a 50 MW fuel pan fire within 5 to 25 seconds in the transverse ventilation tests.&amp;lt;ref name=&amp;quot;Bendelius-21-208&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== See also ==&lt;br /&gt;
* [[Alternative fuel vehicle]]&lt;br /&gt;
* [[Bridge fire]]&lt;br /&gt;
* [[Electric vehicle fire]]&lt;br /&gt;
* [[Motor fuel dispensing facility]]&lt;br /&gt;
&lt;br /&gt;
== Notes ==&lt;br /&gt;
&amp;lt;references /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== References ==&lt;br /&gt;
* Babrauskas, V. (2002b). Heat release rates. In P. J. DiNenno, D. Drysdale, C. L. Beyler, W. D. Walton, R. L. P. Custer, J. R. Hall Jr., &amp;amp; J. M. Watts Jr. (Eds.), &amp;#039;&amp;#039;SFPE handbook of fire protection engineering&amp;#039;&amp;#039; (3rd ed., pp. 3-1–3-37). National Fire Protection Association; Society of Fire Protection Engineers.&lt;br /&gt;
* Bendelius, A. G. (2008). Road tunnels and bridges. In A. E. Cote, C. C. Grant, J. R. Hall Jr., &amp;amp; R. E. Solomon (Eds.), &amp;#039;&amp;#039;Fire protection handbook&amp;#039;&amp;#039; (20th ed., pp. 21-187–21-212). National Fire Protection Association.&lt;br /&gt;
* Budnick, E. K., Hunt, S. P., &amp;amp; Wright, M. T. (2008). Closed form enclosure fire calculations. In A. E. Cote, C. C. Grant, J. R. Hall Jr., &amp;amp; R. E. Solomon (Eds.), &amp;#039;&amp;#039;Fire protection handbook&amp;#039;&amp;#039; (20th ed., pp. 3-145–3-166). National Fire Protection Association.&lt;br /&gt;
* Bukowski, R. W. (2002). Fire hazard assessment for transportation vehicles. In P. J. DiNenno, D. Drysdale, C. L. Beyler, W. D. Walton, R. L. P. Custer, J. R. Hall Jr., &amp;amp; J. M. Watts Jr. (Eds.), &amp;#039;&amp;#039;SFPE handbook of fire protection engineering&amp;#039;&amp;#039; (3rd ed., pp. 5-227–5-233). National Fire Protection Association; Society of Fire Protection Engineers.&lt;br /&gt;
* Long, R. T., Jr., Colwell, J. D., Ray, R., Grossman, H. L., Thomas, B., &amp;amp; Strassburger, R. (2008). Passenger vehicle fires. In A. E. Cote, C. C. Grant, J. R. Hall Jr., &amp;amp; R. E. Solomon (Eds.), &amp;#039;&amp;#039;Fire protection handbook&amp;#039;&amp;#039; (20th ed., pp. 21-3–21-14). National Fire Protection Association.&lt;br /&gt;
* Mawhinney, J. R. (2008). Water mist fire suppression systems. In A. E. Cote, C. C. Grant, J. R. Hall Jr., &amp;amp; R. E. Solomon (Eds.), &amp;#039;&amp;#039;Fire protection handbook&amp;#039;&amp;#039; (20th ed., pp. 16-135–16-180). National Fire Protection Association.&lt;br /&gt;
* Ordile, A. M. (2008). Storage of flammable and combustible liquids. In A. E. Cote, C. C. Grant, J. R. Hall Jr., &amp;amp; R. E. Solomon (Eds.), &amp;#039;&amp;#039;Fire protection handbook&amp;#039;&amp;#039; (20th ed., pp. 7-15–7-33). National Fire Protection Association.&lt;br /&gt;
* Rivkin, C. H. (2008a). Automotive and marine service station operations. In A. E. Cote, C. C. Grant, J. R. Hall Jr., &amp;amp; R. E. Solomon (Eds.), &amp;#039;&amp;#039;Fire protection handbook&amp;#039;&amp;#039; (20th ed., pp. 21-29–21-40). National Fire Protection Association.&lt;br /&gt;
* Rivkin, C. H. (2008b). Vehicle fueling using gaseous fuels. In A. E. Cote, C. C. Grant, J. R. Hall Jr., &amp;amp; R. E. Solomon (Eds.), &amp;#039;&amp;#039;Fire protection handbook&amp;#039;&amp;#039; (20th ed., pp. 21-41–21-76). National Fire Protection Association.&lt;br /&gt;
* Routhier, B. (2008). Fire safety in commercial vehicles. In A. E. Cote, C. C. Grant, J. R. Hall Jr., &amp;amp; R. E. Solomon (Eds.), &amp;#039;&amp;#039;Fire protection handbook&amp;#039;&amp;#039; (20th ed., pp. 21-15–21-27). National Fire Protection Association.&lt;br /&gt;
* Stull, J. O., &amp;amp; Chines, S. A. (2008). Fibers and textiles. In A. E. Cote, C. C. Grant, J. R. Hall Jr., &amp;amp; R. E. Solomon (Eds.), &amp;#039;&amp;#039;Fire protection handbook&amp;#039;&amp;#039; (20th ed., pp. 6-75–6-102). National Fire Protection Association.&lt;br /&gt;
* Van der Graaf, J., Hessels, T., &amp;amp; Rosmuller, N. (2023). &amp;#039;&amp;#039;Fire safety of indoor car parks accommodating electrically powered vehicles&amp;#039;&amp;#039;. Nederlands Instituut Publieke Veiligheid. (Original work published 2021)&lt;br /&gt;
* Van Rossum, E. (2027). &amp;#039;&amp;#039;Introduction to Fire Safety Engineering&amp;#039;&amp;#039;. Fire Safety Academy.&lt;br /&gt;
* Wright, C. J. (2008a). Managing the response to hazardous material incidents. In A. E. Cote, C. C. Grant, J. R. Hall Jr., &amp;amp; R. E. Solomon (Eds.), &amp;#039;&amp;#039;Fire protection handbook&amp;#039;&amp;#039; (20th ed., pp. 13-117–13-144). National Fire Protection Association.&lt;br /&gt;
&lt;br /&gt;
[[Category:Special Hazards &amp;amp; Building Types]]&lt;/div&gt;</summary>
		<author><name>Mark</name></author>
	</entry>
</feed>