<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://fire-safety.academy/w/index.php?action=history&amp;feed=atom&amp;title=Alcohol-resistant_foam</id>
	<title>Alcohol-resistant foam - Revision history</title>
	<link rel="self" type="application/atom+xml" href="https://fire-safety.academy/w/index.php?action=history&amp;feed=atom&amp;title=Alcohol-resistant_foam"/>
	<link rel="alternate" type="text/html" href="https://fire-safety.academy/w/index.php?title=Alcohol-resistant_foam&amp;action=history"/>
	<updated>2026-11-21T22:35:23Z</updated>
	<subtitle>Revision history for this page on the wiki</subtitle>
	<generator>MediaWiki 1.43.11</generator>
	<entry>
		<id>https://fire-safety.academy/w/index.php?title=Alcohol-resistant_foam&amp;diff=9279&amp;oldid=prev</id>
		<title>Peter: Wiki review: corrected 11 errors: citation (8), markup (3) (Claude Opus 5.5)</title>
		<link rel="alternate" type="text/html" href="https://fire-safety.academy/w/index.php?title=Alcohol-resistant_foam&amp;diff=9279&amp;oldid=prev"/>
		<updated>2026-11-15T23:40:05Z</updated>

		<summary type="html">&lt;p&gt;Wiki review: corrected 11 errors: citation (8), markup (3) (Claude Opus 5.5)&lt;/p&gt;
&lt;table style=&quot;background-color: #fff; color: #202122;&quot; data-mw=&quot;interface&quot;&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;tr class=&quot;diff-title&quot; lang=&quot;en&quot;&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;← Older revision&lt;/td&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;Revision as of 00:40, 16 November 2026&lt;/td&gt;
				&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l1&quot;&gt;Line 1:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 1:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&#039;&#039;&#039;Alcohol-resistant foam&#039;&#039;&#039; is a [[Firefighting foam|firefighting foam]] formulated to resist breakdown by specified water-miscible or polar-solvent fuels. The SFPE Handbook describes formulations that create a protective polymeric layer at the fuel interface. This separates the foam from a liquid that could otherwise destroy its aqueous bubble structure.&amp;lt;ref name=&quot;P-795ef6a1bf&quot;&amp;gt;Scheffey (2002), &lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;pp&lt;/del&gt;. 4-89.&amp;lt;/ref&amp;gt;&amp;lt;ref name=&quot;F-fcc18f638f&quot;&amp;gt;Cote et al. (2008), chapter 17.4, &lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;pp&lt;/del&gt;. 17-47.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&#039;&#039;&#039;Alcohol-resistant foam&#039;&#039;&#039; is a [[Firefighting foam|firefighting foam]] formulated to resist breakdown by specified water-miscible or polar-solvent fuels. The SFPE Handbook describes formulations that create a protective polymeric layer at the fuel interface. This separates the foam from a liquid that could otherwise destroy its aqueous bubble structure.&amp;lt;ref name=&quot;P-795ef6a1bf&quot;&amp;gt;Scheffey (2002), &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;p&lt;/ins&gt;. 4-89.&amp;lt;/ref&amp;gt;&amp;lt;ref name=&quot;F-fcc18f638f&quot;&amp;gt;Cote et al. (2008), chapter 17.4, &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;p&lt;/ins&gt;. 17-47.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[[File:fse-alcohol-resistant-foam-v1.svg|thumb|upright=1.5|alt=&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;Show protection of &lt;/del&gt;foam &lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;from &lt;/del&gt;a water-miscible fuel&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;.&lt;/del&gt;|&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;Show protection &lt;/del&gt;of foam from &lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;a &lt;/del&gt;water-miscible fuel.]]&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[[File:fse-alcohol-resistant-foam-v1.svg|thumb|upright=1.5|alt=&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;Conceptual section: &lt;/ins&gt;foam &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;blanket on top, a protective polymeric layer at the fuel interface and &lt;/ins&gt;a water-miscible fuel &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;below&lt;/ins&gt;|&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;Conceptual section &lt;/ins&gt;of &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;a suitable alcohol-resistant formulation: a protective polymeric layer separates the &lt;/ins&gt;foam &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;blanket &lt;/ins&gt;from &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;the &lt;/ins&gt;water-miscible fuel&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;. Products do not all behave identically&lt;/ins&gt;.]]&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The name describes a fuel-compatibility property, rather than one universal chemical recipe. Formulations can use different bases, including [[Aqueous film-forming foam|aqueous film-forming foam]] or [[Protein foam|protein foam]] components. The actual fuel and tested formulation determine the supported application.&amp;lt;ref name=&amp;quot;F-fcc18f638f&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The name describes a fuel-compatibility property, rather than one universal chemical recipe. Formulations can use different bases, including [[Aqueous film-forming foam|aqueous film-forming foam]] or [[Protein foam|protein foam]] components. The actual fuel and tested formulation determine the supported application.&amp;lt;ref name=&amp;quot;F-fcc18f638f&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l17&quot;&gt;Line 17:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 17:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Foam formation and extinguishing action ==&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Foam formation and extinguishing action ==&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The SFPE Handbook describes firefighting foam as air-filled bubbles formed from an aqueous solution. Concentrate is first mixed with water in the specified proportion. Air is then incorporated to create the bubble structure. Concentrate, solution and finished foam consequently refer to different stages, with different volumes. Keeping those stages separate is necessary when interpreting equipment capacities or an application-rate calculation.&amp;lt;ref name=&amp;quot;P-e29e7624aa&amp;quot;&amp;gt;Scheffey (2002), pp. 4-88–4-89.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The SFPE Handbook describes firefighting foam as air-filled bubbles formed from an aqueous solution. Concentrate is first mixed with water in the specified proportion. Air is then incorporated to create the bubble structure. Concentrate, solution and finished foam consequently refer to different stages, with different volumes. Keeping those stages separate is necessary when interpreting equipment capacities or an application-rate calculation.&amp;lt;ref name=&amp;quot;P-e29e7624aa&amp;quot;&amp;gt;Scheffey (2002), pp. 4-88–4-89.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[[File:fse-alcohol-resistant-foam-v2.svg|thumb|upright=1.5|alt=&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;Explain &lt;/del&gt;the &lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;mechanism supporting alcohol-resistant &lt;/del&gt;foam&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;.&lt;/del&gt;|&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;Explain &lt;/del&gt;the &lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;mechanism supporting alcohol-resistant &lt;/del&gt;foam.]]&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[[File:fse-alcohol-resistant-foam-v2.svg|thumb|upright=1.5|alt=&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;Concentrate and water combine into a solution (proportioning); air is then added to &lt;/ins&gt;the &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;solution to form finished &lt;/ins&gt;foam &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;(air expansion), which is applied to the fuel surface&lt;/ins&gt;|&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;Two distinct mixing stages: proportioning concentrate into water, then expanding &lt;/ins&gt;the &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;solution with air. Concentrate, solution and finished &lt;/ins&gt;foam &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;are different volumes&lt;/ins&gt;.]]&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;A foam blanket can suppress the release of combustible vapour from a liquid surface while its water content contributes cooling. The blanket must reach and cover the relevant surface, and sufficient foam must remain despite losses. Film-forming agents add a further mechanism through solution spreading across suitable hydrocarbon fuels. The SFPE discussion distinguishes that film from the bubble blanket and from the behaviour of ordinary protein foam.&amp;lt;ref name=&amp;quot;P-e29e7624aa&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;A foam blanket can suppress the release of combustible vapour from a liquid surface while its water content contributes cooling. The blanket must reach and cover the relevant surface, and sufficient foam must remain despite losses. Film-forming agents add a further mechanism through solution spreading across suitable hydrocarbon fuels. The SFPE discussion distinguishes that film from the bubble blanket and from the behaviour of ordinary protein foam.&amp;lt;ref name=&amp;quot;P-e29e7624aa&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l23&quot;&gt;Line 23:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 23:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Heat, drainage and contact with fuel can reduce the useful foam layer. Mechanical disturbance, including an unsuitable water stream, can also disrupt coverage. The Fire Protection Handbook therefore connects successful application with both supply and losses. A large volume discharged nearby is not necessarily equivalent to a maintained blanket on the burning surface, especially where wind or fire-driven air movement diverts the agent.&amp;lt;ref name=&amp;quot;F-a275fc79a7&amp;quot;&amp;gt;Cote et al. (2008), chapter 17.4, pp. 17-46, 17-49.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Heat, drainage and contact with fuel can reduce the useful foam layer. Mechanical disturbance, including an unsuitable water stream, can also disrupt coverage. The Fire Protection Handbook therefore connects successful application with both supply and losses. A large volume discharged nearby is not necessarily equivalent to a maintained blanket on the burning surface, especially where wind or fire-driven air movement diverts the agent.&amp;lt;ref name=&amp;quot;F-a275fc79a7&amp;quot;&amp;gt;Cote et al. (2008), chapter 17.4, pp. 17-46, 17-49.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The fire geometry limits the mechanism. A stable blanket is particularly relevant to a pool with a reasonably defined surface. Falling or pressurised fuel can create a continuing three-dimensional flame that is not controlled by covering a horizontal surface alone. The SFPE chapter describes combined-agent arrangements for such hazards, while the handbook stresses the need to match application method and fuel conditions.&amp;lt;ref name=&quot;P-1eb9986b02&quot;&amp;gt;Scheffey (2002), &lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;pp&lt;/del&gt;. 4-88.&amp;lt;/ref&amp;gt;&amp;lt;ref name=&quot;F-41e79dad0b&quot;&amp;gt;Cote et al. (2008), chapter 17.4, &lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;pp&lt;/del&gt;. 17-46.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The fire geometry limits the mechanism. A stable blanket is particularly relevant to a pool with a reasonably defined surface. Falling or pressurised fuel can create a continuing three-dimensional flame that is not controlled by covering a horizontal surface alone. The SFPE chapter describes combined-agent arrangements for such hazards, while the handbook stresses the need to match application method and fuel conditions.&amp;lt;ref name=&quot;P-1eb9986b02&quot;&amp;gt;Scheffey (2002), &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;p&lt;/ins&gt;. 4-88.&amp;lt;/ref&amp;gt;&amp;lt;ref name=&quot;F-41e79dad0b&quot;&amp;gt;Cote et al. (2008), chapter 17.4, &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;p&lt;/ins&gt;. 17-46.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Expansion, drainage and stability ==&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Expansion, drainage and stability ==&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Expansion describes how much finished foam is produced from a given volume of solution. It is distinct from the proportion of concentrate in that solution. A solution can be correctly proportioned but poorly aerated, or well expanded while containing an unsuitable concentrate percentage. The handbook treats proportioning, foam generation and distribution as separate operations because each affects the final result.&amp;lt;ref name=&amp;quot;F-04fed1f27d&amp;quot;&amp;gt;Cote et al. (2008), chapter 17.4, pp. 17-49–17-50.&amp;lt;/ref&amp;gt;&amp;lt;ref name=&amp;quot;P-cb791d46af&amp;quot;&amp;gt;Scheffey (2002), pp. 4-88–4-90.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Expansion describes how much finished foam is produced from a given volume of solution. It is distinct from the proportion of concentrate in that solution. A solution can be correctly proportioned but poorly aerated, or well expanded while containing an unsuitable concentrate percentage. The handbook treats proportioning, foam generation and distribution as separate operations because each affects the final result.&amp;lt;ref name=&amp;quot;F-04fed1f27d&amp;quot;&amp;gt;Cote et al. (2008), chapter 17.4, pp. 17-49–17-50.&amp;lt;/ref&amp;gt;&amp;lt;ref name=&amp;quot;P-cb791d46af&amp;quot;&amp;gt;Scheffey (2002), pp. 4-88–4-90.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Drainage describes liquid leaving the bubble structure over time. As liquid drains, the properties of the remaining foam change, affecting spreading and persistence. The handbook identifies the time for a specified fraction to drain as one measure used in foam evaluation. That measurement concerns a physical characteristic under test conditions, rather than a direct universal measure of extinguishing ability.&amp;lt;ref name=&quot;F-2ef4d8b6a4&quot;&amp;gt;Cote et al. (2008), chapter 17.4, &lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;pp&lt;/del&gt;. 17-68.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Drainage describes liquid leaving the bubble structure over time. As liquid drains, the properties of the remaining foam change, affecting spreading and persistence. The handbook identifies the time for a specified fraction to drain as one measure used in foam evaluation. That measurement concerns a physical characteristic under test conditions, rather than a direct universal measure of extinguishing ability.&amp;lt;ref name=&quot;F-2ef4d8b6a4&quot;&amp;gt;Cote et al. (2008), chapter 17.4, &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;p&lt;/ins&gt;. 17-68.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;More expansion is not automatically better. The SFPE discussion of early film-forming foam development describes a compromise between spreading, drainage and bubble stability. A stiff foam can resist flowing around obstructions, while a very wet foam can lose liquid rapidly. The appropriate characteristics depend on whether the task is surface coverage, retention, penetration into a solid fuel or filling a volume.&amp;lt;ref name=&quot;P-5377d100d3&quot;&amp;gt;Scheffey (2002), pp. 4-89–4-90.&amp;lt;/ref&amp;gt;&amp;lt;ref name=&quot;F-11110dd3cd&quot;&amp;gt;Cote et al. (2008), chapter 17.4, &lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;pp&lt;/del&gt;. 17-48.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;More expansion is not automatically better. The SFPE discussion of early film-forming foam development describes a compromise between spreading, drainage and bubble stability. A stiff foam can resist flowing around obstructions, while a very wet foam can lose liquid rapidly. The appropriate characteristics depend on whether the task is surface coverage, retention, penetration into a solid fuel or filling a volume.&amp;lt;ref name=&quot;P-5377d100d3&quot;&amp;gt;Scheffey (2002), pp. 4-89–4-90.&amp;lt;/ref&amp;gt;&amp;lt;ref name=&quot;F-11110dd3cd&quot;&amp;gt;Cote et al. (2008), chapter 17.4, &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;p&lt;/ins&gt;. 17-48.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The generating conditions therefore belong with any reported foam property. Concentrate identity, water quality, pressure, discharge device and air source can all affect the produced foam. High-expansion systems are particularly sensitive to the conditions of the air used for generation. The handbook describes reduced production and stability where hot, contaminated fire gases enter the generator, illustrating why a nominal expansion value is not sufficient by itself.&amp;lt;ref name=&amp;quot;F-2e24d1a4ce&amp;quot;&amp;gt;Cote et al. (2008), chapter 17.4, pp. 17-48–17-50, 17-67.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The generating conditions therefore belong with any reported foam property. Concentrate identity, water quality, pressure, discharge device and air source can all affect the produced foam. High-expansion systems are particularly sensitive to the conditions of the air used for generation. The handbook describes reduced production and stability where hot, contaminated fire gases enter the generator, illustrating why a nominal expansion value is not sufficient by itself.&amp;lt;ref name=&amp;quot;F-2e24d1a4ce&amp;quot;&amp;gt;Cote et al. (2008), chapter 17.4, pp. 17-48–17-50, 17-67.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l48&quot;&gt;Line 48:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 48:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;For liquid surfaces, gentle application can reduce disruption and mixing of foam with fuel. Fixed tank outlets and discharge devices are designed around that requirement and the tank geometry. A monitor operating from outside the hazard must additionally overcome wind, fire updrafts and limitations in positioning. The amount leaving the device can consequently exceed the amount that reaches and remains on the intended surface.&amp;lt;ref name=&amp;quot;F-f3c2d5f4e8&amp;quot;&amp;gt;Cote et al. (2008), chapter 17.4, pp. 17-49, 17-60–17-61.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;For liquid surfaces, gentle application can reduce disruption and mixing of foam with fuel. Fixed tank outlets and discharge devices are designed around that requirement and the tank geometry. A monitor operating from outside the hazard must additionally overcome wind, fire updrafts and limitations in positioning. The amount leaving the device can consequently exceed the amount that reaches and remains on the intended surface.&amp;lt;ref name=&amp;quot;F-f3c2d5f4e8&amp;quot;&amp;gt;Cote et al. (2008), chapter 17.4, pp. 17-49, 17-60–17-61.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Application rate describes solution delivered per unit area per unit time. It is not the same as the volume of expanded foam occupying that area. A successful application has to overcome foam destruction and leave a protective layer. The handbook relates the required rate to fuel, foam and application method, and presents test-based guidance rather than a single rate applicable to every liquid fire.&amp;lt;ref name=&quot;F-c9a598a0c9&quot;&amp;gt;Cote et al. (2008), chapter 17.4, &lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;pp&lt;/del&gt;. 17-49.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Application rate describes solution delivered per unit area per unit time. It is not the same as the volume of expanded foam occupying that area. A successful application has to overcome foam destruction and leave a protective layer. The handbook relates the required rate to fuel, foam and application method, and presents test-based guidance rather than a single rate applicable to every liquid fire.&amp;lt;ref name=&quot;F-c9a598a0c9&quot;&amp;gt;Cote et al. (2008), chapter 17.4, &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;p&lt;/ins&gt;. 17-49.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;High-expansion filling introduces a different delivery problem. The system has to build and retain sufficient foam volume while allowing displaced air to leave. Openings, foam collapse, obstruction and the effects of other water discharges can influence the rate of accumulation. The handbook consequently connects generation capacity with enclosure geometry and the time available to cover the hazard, instead of using expansion ratio alone as the design criterion.&amp;lt;ref name=&quot;F-aae3546b7e&quot;&amp;gt;Cote et al. (2008), chapter 17.4, &lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;pp&lt;/del&gt;. 17-67.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;High-expansion filling introduces a different delivery problem. The system has to build and retain sufficient foam volume while allowing displaced air to leave. Openings, foam collapse, obstruction and the effects of other water discharges can influence the rate of accumulation. The handbook consequently connects generation capacity with enclosure geometry and the time available to cover the hazard, instead of using expansion ratio alone as the design criterion.&amp;lt;ref name=&quot;F-aae3546b7e&quot;&amp;gt;Cote et al. (2008), chapter 17.4, &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;p&lt;/ins&gt;. 17-67.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Fuel compatibility and environmental conditions ==&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Fuel compatibility and environmental conditions ==&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l63&quot;&gt;Line 63:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 63:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Performance evidence and continuing condition ==&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Performance evidence and continuing condition ==&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Foam performance has a strong experimental basis. The SFPE chapter explains that physical properties and small-scale measurements do not always correlate directly with extinguishment in a particular fire test. A test result therefore needs its fuel, scale, equipment and application conditions. A generic claim of good expansion or rapid spreading cannot replace evidence for the intended protection arrangement.&amp;lt;ref name=&amp;quot;P-cb791d46af&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Foam performance has a strong experimental basis. The SFPE chapter explains that physical properties and small-scale measurements do not always correlate directly with extinguishment in a particular fire test. A test result therefore needs its fuel, scale, equipment and application conditions. A generic claim of good expansion or rapid spreading cannot replace evidence for the intended protection arrangement.&amp;lt;ref name=&amp;quot;P-cb791d46af&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[[File:fse-alcohol-resistant-foam-v3.svg|thumb|upright=1.5|alt=&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;Distinguish complementary &lt;/del&gt;evidence &lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;needed &lt;/del&gt;to &lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;assess alcohol-resistant foam.&lt;/del&gt;|&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;Distinguish complementary &lt;/del&gt;evidence &lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;needed to assess &lt;/del&gt;alcohol-resistant foam.]]&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[[File:fse-alcohol-resistant-foam-v3.svg|thumb|upright=1.5|alt=&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;Four measurements, each with what it does not prove: concentration (mixture ratio), expansion (foam to solution volume), drainage (liquid release over time) and discharge pattern (coverage and delivery); together they feed hazard-specific &lt;/ins&gt;evidence&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;, and changed conditions lead &lt;/ins&gt;to &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;review&lt;/ins&gt;|&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;Complementary &lt;/ins&gt;evidence &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;for assessing &lt;/ins&gt;alcohol-resistant foam&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;: concentration, expansion, drainage and discharge pattern. No single observation establishes complete performance&lt;/ins&gt;.]]&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The handbook distinguishes measurements of concentration, expansion, drainage and discharge pattern. These observations address different parts of foam production and application. Concentration examines proportioning; expansion examines incorporation of air; drainage examines changes in the bubble structure. The complete assessment relates these properties to the tested agent and equipment combination rather than selecting one favourable measurement as proof of all-round performance.&amp;lt;ref name=&amp;quot;F-2ef4d8b6a4&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The handbook distinguishes measurements of concentration, expansion, drainage and discharge pattern. These observations address different parts of foam production and application. Concentration examines proportioning; expansion examines incorporation of air; drainage examines changes in the bubble structure. The complete assessment relates these properties to the tested agent and equipment combination rather than selecting one favourable measurement as proof of all-round performance.&amp;lt;ref name=&amp;quot;F-2ef4d8b6a4&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;

&lt;!-- diff cache key firesb_pjbsiy42-wiki_:diff:1.41:old-6467:rev-9279:php=table --&gt;
&lt;/table&gt;</summary>
		<author><name>Peter</name></author>
	</entry>
	<entry>
		<id>https://fire-safety.academy/w/index.php?title=Alcohol-resistant_foam&amp;diff=6467&amp;oldid=prev</id>
		<title>Mark: Remove source references from image captions</title>
		<link rel="alternate" type="text/html" href="https://fire-safety.academy/w/index.php?title=Alcohol-resistant_foam&amp;diff=6467&amp;oldid=prev"/>
		<updated>2026-11-13T07:22:12Z</updated>

		<summary type="html">&lt;p&gt;Remove source references from image captions&lt;/p&gt;
&lt;table style=&quot;background-color: #fff; color: #202122;&quot; data-mw=&quot;interface&quot;&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;tr class=&quot;diff-title&quot; lang=&quot;en&quot;&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;← Older revision&lt;/td&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;Revision as of 08:22, 13 November 2026&lt;/td&gt;
				&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l1&quot;&gt;Line 1:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 1:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&amp;#039;&amp;#039;&amp;#039;Alcohol-resistant foam&amp;#039;&amp;#039;&amp;#039; is a [[Firefighting foam|firefighting foam]] formulated to resist breakdown by specified water-miscible or polar-solvent fuels. The SFPE Handbook describes formulations that create a protective polymeric layer at the fuel interface. This separates the foam from a liquid that could otherwise destroy its aqueous bubble structure.&amp;lt;ref name=&amp;quot;P-795ef6a1bf&amp;quot;&amp;gt;Scheffey (2002), pp. 4-89.&amp;lt;/ref&amp;gt;&amp;lt;ref name=&amp;quot;F-fcc18f638f&amp;quot;&amp;gt;Cote et al. (2008), chapter 17.4, pp. 17-47.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&amp;#039;&amp;#039;&amp;#039;Alcohol-resistant foam&amp;#039;&amp;#039;&amp;#039; is a [[Firefighting foam|firefighting foam]] formulated to resist breakdown by specified water-miscible or polar-solvent fuels. The SFPE Handbook describes formulations that create a protective polymeric layer at the fuel interface. This separates the foam from a liquid that could otherwise destroy its aqueous bubble structure.&amp;lt;ref name=&amp;quot;P-795ef6a1bf&amp;quot;&amp;gt;Scheffey (2002), pp. 4-89.&amp;lt;/ref&amp;gt;&amp;lt;ref name=&amp;quot;F-fcc18f638f&amp;quot;&amp;gt;Cote et al. (2008), chapter 17.4, pp. 17-47.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[[File:fse-alcohol-resistant-foam-v1.svg|thumb|upright=1.5|alt=Show protection of foam from a water-miscible fuel.|Show protection of foam from a water-miscible fuel&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;. Based on Scheffey (2002), pp. 4-89; Cote et al. (2008), chapter 17.4, pp. 17-47; Cote et al. (2008), chapter 17.4, pp. 17-46–17-49, 17-64&lt;/del&gt;.]]&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[[File:fse-alcohol-resistant-foam-v1.svg|thumb|upright=1.5|alt=Show protection of foam from a water-miscible fuel.|Show protection of foam from a water-miscible fuel.]]&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The name describes a fuel-compatibility property, rather than one universal chemical recipe. Formulations can use different bases, including [[Aqueous film-forming foam|aqueous film-forming foam]] or [[Protein foam|protein foam]] components. The actual fuel and tested formulation determine the supported application.&amp;lt;ref name=&amp;quot;F-fcc18f638f&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The name describes a fuel-compatibility property, rather than one universal chemical recipe. Formulations can use different bases, including [[Aqueous film-forming foam|aqueous film-forming foam]] or [[Protein foam|protein foam]] components. The actual fuel and tested formulation determine the supported application.&amp;lt;ref name=&amp;quot;F-fcc18f638f&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l17&quot;&gt;Line 17:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 17:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Foam formation and extinguishing action ==&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Foam formation and extinguishing action ==&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The SFPE Handbook describes firefighting foam as air-filled bubbles formed from an aqueous solution. Concentrate is first mixed with water in the specified proportion. Air is then incorporated to create the bubble structure. Concentrate, solution and finished foam consequently refer to different stages, with different volumes. Keeping those stages separate is necessary when interpreting equipment capacities or an application-rate calculation.&amp;lt;ref name=&amp;quot;P-e29e7624aa&amp;quot;&amp;gt;Scheffey (2002), pp. 4-88–4-89.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The SFPE Handbook describes firefighting foam as air-filled bubbles formed from an aqueous solution. Concentrate is first mixed with water in the specified proportion. Air is then incorporated to create the bubble structure. Concentrate, solution and finished foam consequently refer to different stages, with different volumes. Keeping those stages separate is necessary when interpreting equipment capacities or an application-rate calculation.&amp;lt;ref name=&amp;quot;P-e29e7624aa&amp;quot;&amp;gt;Scheffey (2002), pp. 4-88–4-89.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[[File:fse-alcohol-resistant-foam-v2.svg|thumb|upright=1.5|alt=Explain the mechanism supporting alcohol-resistant foam.|Explain the mechanism supporting alcohol-resistant foam&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;. Based on Scheffey (2002), pp. 4-88–4-89; Cote et al. (2008), chapter 17.4, pp. 17-46, 17-49; Scheffey (2002), pp. 4-88&lt;/del&gt;.]]&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[[File:fse-alcohol-resistant-foam-v2.svg|thumb|upright=1.5|alt=Explain the mechanism supporting alcohol-resistant foam.|Explain the mechanism supporting alcohol-resistant foam.]]&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;A foam blanket can suppress the release of combustible vapour from a liquid surface while its water content contributes cooling. The blanket must reach and cover the relevant surface, and sufficient foam must remain despite losses. Film-forming agents add a further mechanism through solution spreading across suitable hydrocarbon fuels. The SFPE discussion distinguishes that film from the bubble blanket and from the behaviour of ordinary protein foam.&amp;lt;ref name=&amp;quot;P-e29e7624aa&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;A foam blanket can suppress the release of combustible vapour from a liquid surface while its water content contributes cooling. The blanket must reach and cover the relevant surface, and sufficient foam must remain despite losses. Film-forming agents add a further mechanism through solution spreading across suitable hydrocarbon fuels. The SFPE discussion distinguishes that film from the bubble blanket and from the behaviour of ordinary protein foam.&amp;lt;ref name=&amp;quot;P-e29e7624aa&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l63&quot;&gt;Line 63:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 63:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Performance evidence and continuing condition ==&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Performance evidence and continuing condition ==&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Foam performance has a strong experimental basis. The SFPE chapter explains that physical properties and small-scale measurements do not always correlate directly with extinguishment in a particular fire test. A test result therefore needs its fuel, scale, equipment and application conditions. A generic claim of good expansion or rapid spreading cannot replace evidence for the intended protection arrangement.&amp;lt;ref name=&amp;quot;P-cb791d46af&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Foam performance has a strong experimental basis. The SFPE chapter explains that physical properties and small-scale measurements do not always correlate directly with extinguishment in a particular fire test. A test result therefore needs its fuel, scale, equipment and application conditions. A generic claim of good expansion or rapid spreading cannot replace evidence for the intended protection arrangement.&amp;lt;ref name=&amp;quot;P-cb791d46af&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[[File:fse-alcohol-resistant-foam-v3.svg|thumb|upright=1.5|alt=Distinguish complementary evidence needed to assess alcohol-resistant foam.|Distinguish complementary evidence needed to assess alcohol-resistant foam&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;. Based on Scheffey (2002), pp. 4-88–4-90; Cote et al. (2008), chapter 17.4, pp. 17-68; National Research Council of Canada et al. (2005), §0.3.2.6–0.3.2.8; pp. 0.3-6–0.3-7&lt;/del&gt;.]]&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[[File:fse-alcohol-resistant-foam-v3.svg|thumb|upright=1.5|alt=Distinguish complementary evidence needed to assess alcohol-resistant foam.|Distinguish complementary evidence needed to assess alcohol-resistant foam.]]&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The handbook distinguishes measurements of concentration, expansion, drainage and discharge pattern. These observations address different parts of foam production and application. Concentration examines proportioning; expansion examines incorporation of air; drainage examines changes in the bubble structure. The complete assessment relates these properties to the tested agent and equipment combination rather than selecting one favourable measurement as proof of all-round performance.&amp;lt;ref name=&amp;quot;F-2ef4d8b6a4&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The handbook distinguishes measurements of concentration, expansion, drainage and discharge pattern. These observations address different parts of foam production and application. Concentration examines proportioning; expansion examines incorporation of air; drainage examines changes in the bubble structure. The complete assessment relates these properties to the tested agent and equipment combination rather than selecting one favourable measurement as proof of all-round performance.&amp;lt;ref name=&amp;quot;F-2ef4d8b6a4&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;

&lt;!-- diff cache key firesb_pjbsiy42-wiki_:diff:1.41:old-6012:rev-6467:php=table --&gt;
&lt;/table&gt;</summary>
		<author><name>Mark</name></author>
	</entry>
	<entry>
		<id>https://fire-safety.academy/w/index.php?title=Alcohol-resistant_foam&amp;diff=6012&amp;oldid=prev</id>
		<title>Peter: Add SVG figures fse-alcohol-resistant-foam-v1.svg, fse-alcohol-resistant-foam-v2.svg, fse-alcohol-resistant-foam-v3.svg (list-4 visual plan)</title>
		<link rel="alternate" type="text/html" href="https://fire-safety.academy/w/index.php?title=Alcohol-resistant_foam&amp;diff=6012&amp;oldid=prev"/>
		<updated>2026-11-12T14:55:50Z</updated>

		<summary type="html">&lt;p&gt;Add SVG figures fse-alcohol-resistant-foam-v1.svg, fse-alcohol-resistant-foam-v2.svg, fse-alcohol-resistant-foam-v3.svg (list-4 visual plan)&lt;/p&gt;
&lt;table style=&quot;background-color: #fff; color: #202122;&quot; data-mw=&quot;interface&quot;&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;tr class=&quot;diff-title&quot; lang=&quot;en&quot;&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;← Older revision&lt;/td&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;Revision as of 15:55, 12 November 2026&lt;/td&gt;
				&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l1&quot;&gt;Line 1:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 1:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&amp;#039;&amp;#039;&amp;#039;Alcohol-resistant foam&amp;#039;&amp;#039;&amp;#039; is a [[Firefighting foam|firefighting foam]] formulated to resist breakdown by specified water-miscible or polar-solvent fuels. The SFPE Handbook describes formulations that create a protective polymeric layer at the fuel interface. This separates the foam from a liquid that could otherwise destroy its aqueous bubble structure.&amp;lt;ref name=&amp;quot;P-795ef6a1bf&amp;quot;&amp;gt;Scheffey (2002), pp. 4-89.&amp;lt;/ref&amp;gt;&amp;lt;ref name=&amp;quot;F-fcc18f638f&amp;quot;&amp;gt;Cote et al. (2008), chapter 17.4, pp. 17-47.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&amp;#039;&amp;#039;&amp;#039;Alcohol-resistant foam&amp;#039;&amp;#039;&amp;#039; is a [[Firefighting foam|firefighting foam]] formulated to resist breakdown by specified water-miscible or polar-solvent fuels. The SFPE Handbook describes formulations that create a protective polymeric layer at the fuel interface. This separates the foam from a liquid that could otherwise destroy its aqueous bubble structure.&amp;lt;ref name=&amp;quot;P-795ef6a1bf&amp;quot;&amp;gt;Scheffey (2002), pp. 4-89.&amp;lt;/ref&amp;gt;&amp;lt;ref name=&amp;quot;F-fcc18f638f&amp;quot;&amp;gt;Cote et al. (2008), chapter 17.4, pp. 17-47.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-deleted&quot;&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;[[File:fse-alcohol-resistant-foam-v1.svg|thumb|upright=1.5|alt=Show protection of foam from a water-miscible fuel.|Show protection of foam from a water-miscible fuel. Based on Scheffey (2002), pp. 4-89; Cote et al. (2008), chapter 17.4, pp. 17-47; Cote et al. (2008), chapter 17.4, pp. 17-46–17-49, 17-64.]]&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The name describes a fuel-compatibility property, rather than one universal chemical recipe. Formulations can use different bases, including [[Aqueous film-forming foam|aqueous film-forming foam]] or [[Protein foam|protein foam]] components. The actual fuel and tested formulation determine the supported application.&amp;lt;ref name=&amp;quot;F-fcc18f638f&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The name describes a fuel-compatibility property, rather than one universal chemical recipe. Formulations can use different bases, including [[Aqueous film-forming foam|aqueous film-forming foam]] or [[Protein foam|protein foam]] components. The actual fuel and tested formulation determine the supported application.&amp;lt;ref name=&amp;quot;F-fcc18f638f&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l16&quot;&gt;Line 16:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 17:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Foam formation and extinguishing action ==&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Foam formation and extinguishing action ==&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The SFPE Handbook describes firefighting foam as air-filled bubbles formed from an aqueous solution. Concentrate is first mixed with water in the specified proportion. Air is then incorporated to create the bubble structure. Concentrate, solution and finished foam consequently refer to different stages, with different volumes. Keeping those stages separate is necessary when interpreting equipment capacities or an application-rate calculation.&amp;lt;ref name=&amp;quot;P-e29e7624aa&amp;quot;&amp;gt;Scheffey (2002), pp. 4-88–4-89.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The SFPE Handbook describes firefighting foam as air-filled bubbles formed from an aqueous solution. Concentrate is first mixed with water in the specified proportion. Air is then incorporated to create the bubble structure. Concentrate, solution and finished foam consequently refer to different stages, with different volumes. Keeping those stages separate is necessary when interpreting equipment capacities or an application-rate calculation.&amp;lt;ref name=&amp;quot;P-e29e7624aa&amp;quot;&amp;gt;Scheffey (2002), pp. 4-88–4-89.&amp;lt;/ref&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-deleted&quot;&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;[[File:fse-alcohol-resistant-foam-v2.svg|thumb|upright=1.5|alt=Explain the mechanism supporting alcohol-resistant foam.|Explain the mechanism supporting alcohol-resistant foam. Based on Scheffey (2002), pp. 4-88–4-89; Cote et al. (2008), chapter 17.4, pp. 17-46, 17-49; Scheffey (2002), pp. 4-88.]]&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;A foam blanket can suppress the release of combustible vapour from a liquid surface while its water content contributes cooling. The blanket must reach and cover the relevant surface, and sufficient foam must remain despite losses. Film-forming agents add a further mechanism through solution spreading across suitable hydrocarbon fuels. The SFPE discussion distinguishes that film from the bubble blanket and from the behaviour of ordinary protein foam.&amp;lt;ref name=&amp;quot;P-e29e7624aa&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;A foam blanket can suppress the release of combustible vapour from a liquid surface while its water content contributes cooling. The blanket must reach and cover the relevant surface, and sufficient foam must remain despite losses. Film-forming agents add a further mechanism through solution spreading across suitable hydrocarbon fuels. The SFPE discussion distinguishes that film from the bubble blanket and from the behaviour of ordinary protein foam.&amp;lt;ref name=&amp;quot;P-e29e7624aa&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l61&quot;&gt;Line 61:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 63:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Performance evidence and continuing condition ==&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;== Performance evidence and continuing condition ==&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Foam performance has a strong experimental basis. The SFPE chapter explains that physical properties and small-scale measurements do not always correlate directly with extinguishment in a particular fire test. A test result therefore needs its fuel, scale, equipment and application conditions. A generic claim of good expansion or rapid spreading cannot replace evidence for the intended protection arrangement.&amp;lt;ref name=&amp;quot;P-cb791d46af&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Foam performance has a strong experimental basis. The SFPE chapter explains that physical properties and small-scale measurements do not always correlate directly with extinguishment in a particular fire test. A test result therefore needs its fuel, scale, equipment and application conditions. A generic claim of good expansion or rapid spreading cannot replace evidence for the intended protection arrangement.&amp;lt;ref name=&amp;quot;P-cb791d46af&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-deleted&quot;&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;[[File:fse-alcohol-resistant-foam-v3.svg|thumb|upright=1.5|alt=Distinguish complementary evidence needed to assess alcohol-resistant foam.|Distinguish complementary evidence needed to assess alcohol-resistant foam. Based on Scheffey (2002), pp. 4-88–4-90; Cote et al. (2008), chapter 17.4, pp. 17-68; National Research Council of Canada et al. (2005), §0.3.2.6–0.3.2.8; pp. 0.3-6–0.3-7.]]&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The handbook distinguishes measurements of concentration, expansion, drainage and discharge pattern. These observations address different parts of foam production and application. Concentration examines proportioning; expansion examines incorporation of air; drainage examines changes in the bubble structure. The complete assessment relates these properties to the tested agent and equipment combination rather than selecting one favourable measurement as proof of all-round performance.&amp;lt;ref name=&amp;quot;F-2ef4d8b6a4&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The handbook distinguishes measurements of concentration, expansion, drainage and discharge pattern. These observations address different parts of foam production and application. Concentration examines proportioning; expansion examines incorporation of air; drainage examines changes in the bubble structure. The complete assessment relates these properties to the tested agent and equipment combination rather than selecting one favourable measurement as proof of all-round performance.&amp;lt;ref name=&amp;quot;F-2ef4d8b6a4&amp;quot; /&amp;gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;

&lt;!-- diff cache key firesb_pjbsiy42-wiki_:diff:1.41:old-3869:rev-6012:php=table --&gt;
&lt;/table&gt;</summary>
		<author><name>Peter</name></author>
	</entry>
	<entry>
		<id>https://fire-safety.academy/w/index.php?title=Alcohol-resistant_foam&amp;diff=3869&amp;oldid=prev</id>
		<title>Thomas: New FSE wiki article: Alcohol-resistant foam (written by GPT-6)</title>
		<link rel="alternate" type="text/html" href="https://fire-safety.academy/w/index.php?title=Alcohol-resistant_foam&amp;diff=3869&amp;oldid=prev"/>
		<updated>2026-11-07T21:39:41Z</updated>

		<summary type="html">&lt;p&gt;New FSE wiki article: Alcohol-resistant foam (written by GPT-6)&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;&amp;#039;&amp;#039;&amp;#039;Alcohol-resistant foam&amp;#039;&amp;#039;&amp;#039; is a [[Firefighting foam|firefighting foam]] formulated to resist breakdown by specified water-miscible or polar-solvent fuels. The SFPE Handbook describes formulations that create a protective polymeric layer at the fuel interface. This separates the foam from a liquid that could otherwise destroy its aqueous bubble structure.&amp;lt;ref name=&amp;quot;P-795ef6a1bf&amp;quot;&amp;gt;Scheffey (2002), pp. 4-89.&amp;lt;/ref&amp;gt;&amp;lt;ref name=&amp;quot;F-fcc18f638f&amp;quot;&amp;gt;Cote et al. (2008), chapter 17.4, pp. 17-47.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
The name describes a fuel-compatibility property, rather than one universal chemical recipe. Formulations can use different bases, including [[Aqueous film-forming foam|aqueous film-forming foam]] or [[Protein foam|protein foam]] components. The actual fuel and tested formulation determine the supported application.&amp;lt;ref name=&amp;quot;F-fcc18f638f&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
A [[Pool fire|pool fire]] involving a polar solvent differs from one involving an immiscible hydrocarbon. [[Flammable and combustible liquid classification]] provides hazard context, but does not by itself establish foam compatibility. [[Foam application rate]] and the discharge method must also match the particular fuel and system evidence.&amp;lt;ref name=&amp;quot;F-d37420ebc2&amp;quot;&amp;gt;Cote et al. (2008), chapter 17.4, pp. 17-46–17-49, 17-64.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== Characteristics and practical interpretation ==&lt;br /&gt;
Water-miscible liquids can draw liquid from or otherwise disrupt ordinary foam. The handbook identifies alcohols, ketones and other polar solvents as examples requiring specific assessment. It also notes that mixtures containing these substances can affect conventional foam. A broad hydrocarbon description is therefore insufficient where the actual fuel contains a foam-destructive component.&amp;lt;ref name=&amp;quot;F-fcc18f638f&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
The polymeric layer described in the SFPE treatment provides a barrier between the fuel and foam. Its role differs from the freely spreading aqueous film produced on a suitable hydrocarbon by a film-forming agent. The same product can behave differently on these two fuel groups. The protection mechanism and test evidence need to follow the fuel actually present.&amp;lt;ref name=&amp;quot;P-795ef6a1bf&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;F-fcc18f638f&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Application conditions also matter. The handbook relates required rates and methods to the particular polar solvent and listing. Gentle application can help preserve the protective structure, while inappropriate plunging can disrupt it. A generic alcohol-resistant label therefore does not supply one rate or one nozzle arrangement for every water-miscible liquid.&amp;lt;ref name=&amp;quot;F-a6842d491c&amp;quot;&amp;gt;Cote et al. (2008), chapter 17.4, pp. 17-49, 17-60, 17-64.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Some formulations have viscosity characteristics that affect proportioning. The handbook discusses additional losses in concentrate piping and the resulting limits at low water flows. This can be significant in closed sprinkler arrangements before many outlets operate. Compatibility therefore extends beyond fuel resistance to the proportioner, concentrate piping and discharge device operating together.&amp;lt;ref name=&amp;quot;F-1653f2a790&amp;quot;&amp;gt;Cote et al. (2008), chapter 17.4, pp. 17-52, 17-64.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== Foam formation and extinguishing action ==&lt;br /&gt;
The SFPE Handbook describes firefighting foam as air-filled bubbles formed from an aqueous solution. Concentrate is first mixed with water in the specified proportion. Air is then incorporated to create the bubble structure. Concentrate, solution and finished foam consequently refer to different stages, with different volumes. Keeping those stages separate is necessary when interpreting equipment capacities or an application-rate calculation.&amp;lt;ref name=&amp;quot;P-e29e7624aa&amp;quot;&amp;gt;Scheffey (2002), pp. 4-88–4-89.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
A foam blanket can suppress the release of combustible vapour from a liquid surface while its water content contributes cooling. The blanket must reach and cover the relevant surface, and sufficient foam must remain despite losses. Film-forming agents add a further mechanism through solution spreading across suitable hydrocarbon fuels. The SFPE discussion distinguishes that film from the bubble blanket and from the behaviour of ordinary protein foam.&amp;lt;ref name=&amp;quot;P-e29e7624aa&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Heat, drainage and contact with fuel can reduce the useful foam layer. Mechanical disturbance, including an unsuitable water stream, can also disrupt coverage. The Fire Protection Handbook therefore connects successful application with both supply and losses. A large volume discharged nearby is not necessarily equivalent to a maintained blanket on the burning surface, especially where wind or fire-driven air movement diverts the agent.&amp;lt;ref name=&amp;quot;F-a275fc79a7&amp;quot;&amp;gt;Cote et al. (2008), chapter 17.4, pp. 17-46, 17-49.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
The fire geometry limits the mechanism. A stable blanket is particularly relevant to a pool with a reasonably defined surface. Falling or pressurised fuel can create a continuing three-dimensional flame that is not controlled by covering a horizontal surface alone. The SFPE chapter describes combined-agent arrangements for such hazards, while the handbook stresses the need to match application method and fuel conditions.&amp;lt;ref name=&amp;quot;P-1eb9986b02&amp;quot;&amp;gt;Scheffey (2002), pp. 4-88.&amp;lt;/ref&amp;gt;&amp;lt;ref name=&amp;quot;F-41e79dad0b&amp;quot;&amp;gt;Cote et al. (2008), chapter 17.4, pp. 17-46.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== Expansion, drainage and stability ==&lt;br /&gt;
Expansion describes how much finished foam is produced from a given volume of solution. It is distinct from the proportion of concentrate in that solution. A solution can be correctly proportioned but poorly aerated, or well expanded while containing an unsuitable concentrate percentage. The handbook treats proportioning, foam generation and distribution as separate operations because each affects the final result.&amp;lt;ref name=&amp;quot;F-04fed1f27d&amp;quot;&amp;gt;Cote et al. (2008), chapter 17.4, pp. 17-49–17-50.&amp;lt;/ref&amp;gt;&amp;lt;ref name=&amp;quot;P-cb791d46af&amp;quot;&amp;gt;Scheffey (2002), pp. 4-88–4-90.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Drainage describes liquid leaving the bubble structure over time. As liquid drains, the properties of the remaining foam change, affecting spreading and persistence. The handbook identifies the time for a specified fraction to drain as one measure used in foam evaluation. That measurement concerns a physical characteristic under test conditions, rather than a direct universal measure of extinguishing ability.&amp;lt;ref name=&amp;quot;F-2ef4d8b6a4&amp;quot;&amp;gt;Cote et al. (2008), chapter 17.4, pp. 17-68.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
More expansion is not automatically better. The SFPE discussion of early film-forming foam development describes a compromise between spreading, drainage and bubble stability. A stiff foam can resist flowing around obstructions, while a very wet foam can lose liquid rapidly. The appropriate characteristics depend on whether the task is surface coverage, retention, penetration into a solid fuel or filling a volume.&amp;lt;ref name=&amp;quot;P-5377d100d3&amp;quot;&amp;gt;Scheffey (2002), pp. 4-89–4-90.&amp;lt;/ref&amp;gt;&amp;lt;ref name=&amp;quot;F-11110dd3cd&amp;quot;&amp;gt;Cote et al. (2008), chapter 17.4, pp. 17-48.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
The generating conditions therefore belong with any reported foam property. Concentrate identity, water quality, pressure, discharge device and air source can all affect the produced foam. High-expansion systems are particularly sensitive to the conditions of the air used for generation. The handbook describes reduced production and stability where hot, contaminated fire gases enter the generator, illustrating why a nominal expansion value is not sufficient by itself.&amp;lt;ref name=&amp;quot;F-2e24d1a4ce&amp;quot;&amp;gt;Cote et al. (2008), chapter 17.4, pp. 17-48–17-50, 17-67.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== Proportioning and operating range ==&lt;br /&gt;
Proportioning establishes the concentrate fraction in the water-based solution. The handbook distinguishes systems that draw concentrate using a low-pressure region from systems that inject it using a pump or pressure head. Both must deliver the intended ratio under the relevant operating conditions. The proportioner is consequently matched to the concentrate, water supply and downstream discharge equipment.&amp;lt;ref name=&amp;quot;F-3ff37d7083&amp;quot;&amp;gt;Cote et al. (2008), chapter 17.4, pp. 17-50–17-52.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
A venturi eductor uses the flowing water&amp;#039;s pressure energy to create a region into which concentrate is drawn. Its performance depends on inlet conditions and the resistance downstream. Hose length, elevation and the discharge device can therefore affect the resulting mixture. The handbook&amp;#039;s discussion of in-line eductors makes this dependence explicit, rather than treating the metering setting alone as evidence of correct proportioning.&amp;lt;ref name=&amp;quot;F-4141d8cff4&amp;quot;&amp;gt;Cote et al. (2008), chapter 17.4, pp. 17-50–17-51.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Balanced-pressure and bladder arrangements establish the concentrate supply differently. Their useful operating range still has limits, particularly at low water flows. The handbook identifies the possibility of under-proportioning before a bladder arrangement reaches its approved flow range. Higher concentrate viscosity can increase losses in the concentrate piping and affect that limit. These issues are especially relevant when only a small number of closed sprinklers initially operate.&amp;lt;ref name=&amp;quot;F-77b0a3af40&amp;quot;&amp;gt;Cote et al. (2008), chapter 17.4, pp. 17-51–17-52.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
The mixture also affects available operating time. Too little concentrate can produce unsuitable foam, while excessive concentrate consumes the stored supply more rapidly. Verification therefore measures the delivered concentration under representative conditions, rather than relying only on the quantity originally placed in the tank. The handbook treats concentration testing as evidence about the proportioning system and distinguishes it from expansion and drainage measurements.&amp;lt;ref name=&amp;quot;F-6db4d5a963&amp;quot;&amp;gt;Cote et al. (2008), chapter 17.4, pp. 17-50, 17-68.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== Application method and useful delivery ==&lt;br /&gt;
Foam can be delivered through hand-held devices, monitors, fixed outlets and sprinkler arrangements. These methods differ in reach, aeration, distribution and dependence on operator positioning. The handbook therefore treats the discharge equipment as part of the tested system. Substituting a different nozzle can change foam quality and coverage even when the solution concentration remains the same.&amp;lt;ref name=&amp;quot;F-579ba26664&amp;quot;&amp;gt;Cote et al. (2008), chapter 17.4, pp. 17-59–17-61, 17-64.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
For liquid surfaces, gentle application can reduce disruption and mixing of foam with fuel. Fixed tank outlets and discharge devices are designed around that requirement and the tank geometry. A monitor operating from outside the hazard must additionally overcome wind, fire updrafts and limitations in positioning. The amount leaving the device can consequently exceed the amount that reaches and remains on the intended surface.&amp;lt;ref name=&amp;quot;F-f3c2d5f4e8&amp;quot;&amp;gt;Cote et al. (2008), chapter 17.4, pp. 17-49, 17-60–17-61.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Application rate describes solution delivered per unit area per unit time. It is not the same as the volume of expanded foam occupying that area. A successful application has to overcome foam destruction and leave a protective layer. The handbook relates the required rate to fuel, foam and application method, and presents test-based guidance rather than a single rate applicable to every liquid fire.&amp;lt;ref name=&amp;quot;F-c9a598a0c9&amp;quot;&amp;gt;Cote et al. (2008), chapter 17.4, pp. 17-49.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
High-expansion filling introduces a different delivery problem. The system has to build and retain sufficient foam volume while allowing displaced air to leave. Openings, foam collapse, obstruction and the effects of other water discharges can influence the rate of accumulation. The handbook consequently connects generation capacity with enclosure geometry and the time available to cover the hazard, instead of using expansion ratio alone as the design criterion.&amp;lt;ref name=&amp;quot;F-aae3546b7e&amp;quot;&amp;gt;Cote et al. (2008), chapter 17.4, pp. 17-67.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== Fuel compatibility and environmental conditions ==&lt;br /&gt;
The fuel&amp;#039;s interaction with the aqueous phase is a principal selection issue. Ordinary foam can break down rapidly on water-miscible polar solvents. Alcohol-resistant formulations provide protection appropriate to specified fuels, with some formulations forming a polymeric layer between fuel and foam. The SFPE and NFPA handbooks both distinguish this function from ordinary film formation on a hydrocarbon surface.&amp;lt;ref name=&amp;quot;P-795ef6a1bf&amp;quot; /&amp;gt;&amp;lt;ref name=&amp;quot;F-b8bcea31cb&amp;quot;&amp;gt;Cote et al. (2008), chapter 17.4, pp. 17-47–17-49.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Fuel temperature and geometry also influence performance. Hot liquid can destroy foam or cause disruptive boiling of its water content, while a continuing fuel release can prevent a stable blanket from developing. Compatibility therefore means more than assigning a general liquid-fire label. The agent, fuel, temperature, application method and tested protection arrangement define the conditions supporting an extinguishing claim.&amp;lt;ref name=&amp;quot;F-62ad716b6d&amp;quot;&amp;gt;Cote et al. (2008), chapter 17.4, pp. 17-46–17-49.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Water and air quality affect the generated product. Contaminated water can change foam properties, and smoke-laden or hot air can reduce high-expansion foam production. Equipment location must consequently be considered relative to the fire environment. The handbook identifies these effects as practical limitations on foam generation and distribution, alongside the influence of weather where foam is used outdoors.&amp;lt;ref name=&amp;quot;F-40e2680162&amp;quot;&amp;gt;Cote et al. (2008), chapter 17.4, pp. 17-48–17-49, 17-67.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Discharged solution can also carry fuel and other contaminants beyond the protected area. Environmental assessment therefore includes containment, drainage and the characteristics of the particular formulation. The handbook discusses toxicity, persistence, treatment and oxygen demand as different concerns. Its historical statements about named products or regulatory status do not establish the current acceptability of a formulation or an uncontrolled release.&amp;lt;ref name=&amp;quot;F-992b34afe2&amp;quot;&amp;gt;Cote et al. (2008), chapter 17.4, pp. 17-68–17-69.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== Performance evidence and continuing condition ==&lt;br /&gt;
Foam performance has a strong experimental basis. The SFPE chapter explains that physical properties and small-scale measurements do not always correlate directly with extinguishment in a particular fire test. A test result therefore needs its fuel, scale, equipment and application conditions. A generic claim of good expansion or rapid spreading cannot replace evidence for the intended protection arrangement.&amp;lt;ref name=&amp;quot;P-cb791d46af&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
The handbook distinguishes measurements of concentration, expansion, drainage and discharge pattern. These observations address different parts of foam production and application. Concentration examines proportioning; expansion examines incorporation of air; drainage examines changes in the bubble structure. The complete assessment relates these properties to the tested agent and equipment combination rather than selecting one favourable measurement as proof of all-round performance.&amp;lt;ref name=&amp;quot;F-2ef4d8b6a4&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Stored concentrate can change through contamination, extreme temperatures or separation. Pumps, valves and small openings can also deteriorate or become obstructed. The handbook consequently treats concentrate surveillance and equipment inspection as separate continuing tasks. Testing arrangements can sometimes assess components without distributing foam over the hazard, but the recorded scope needs to identify which functions were actually demonstrated.&amp;lt;ref name=&amp;quot;F-2ef4d8b6a4&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Changes to the protected use can invalidate a previously suitable system. A different fuel, altered storage height or revised discharge route can change the conditions supporting the original test evidence. The IFEG lifecycle framework connects alterations with review of the fire engineering assessment. This makes maintaining the design basis part of continuing protection, alongside maintaining the physical condition of tanks, proportioners and outlets.&amp;lt;ref name=&amp;quot;I-7b0907c015&amp;quot;&amp;gt;National Research Council of Canada et al. (2005), §0.3.2.6–0.3.2.8; pp. 0.3-6–0.3-7.&amp;lt;/ref&amp;gt;&amp;lt;ref name=&amp;quot;F-6527793bc1&amp;quot;&amp;gt;Cote et al. (2008), chapter 17.4, pp. 17-64, 17-68.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== Protection objectives and limits of performance ==&lt;br /&gt;
Suppression describes an intended change in a fire, but the required outcome needs further definition. Control can limit growth or reduce the rate of heat release without extinguishing every burning item. Extinguishment removes the continuing combustion under the conditions considered. Prevention of renewed burning may require cooling, continued agent retention or removal of an ignition source. These outcomes impose different demands on the protection arrangement.&amp;lt;ref name=&amp;quot;F-a7e389f0f3&amp;quot;&amp;gt;Cote et al. (2008), chapter 17.3, pp. 17-32–17-33.&amp;lt;/ref&amp;gt;&amp;lt;ref name=&amp;quot;F-5d55059c9a&amp;quot;&amp;gt;Cote et al. (2008), chapter 17.6, pp. 17-119–17-121.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Agent selection follows the fuel and the objective. Water can cool a solid surface, foam can maintain a barrier over a liquid, and a gaseous agent can change the atmosphere surrounding a fire. None of these descriptions establishes universal effectiveness. The protected material, fire geometry, ventilation and available delivery arrangement determine whether the relevant mechanism can operate where it is needed.&amp;lt;ref name=&amp;quot;F-4ad60f14bc&amp;quot;&amp;gt;Cote et al. (2008), chapter 17.3, pp. 17-32–17-33, 17-36–17-38.&amp;lt;/ref&amp;gt;&amp;lt;ref name=&amp;quot;F-36233581a2&amp;quot;&amp;gt;Cote et al. (2008), chapter 17.4, pp. 17-45–17-49.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
The assessment also distinguishes successful operation from unsuccessful or delayed operation. An explicit example appears in Australia&amp;#039;s Fire Safety Verification Method Standard, 2022 edition. Its structural-stability scenario considers failures of suppression, delayed fire brigade intervention and combinations of failures. That requirement belongs to the Australian method and its stated scenario. It illustrates why the mere presence of equipment is insufficient evidence of the building&amp;#039;s performance.&amp;lt;ref name=&amp;quot;B-2b63577d33&amp;quot;&amp;gt;Australian Building Codes Board (2022), §2.12.2; p. 19.&amp;lt;/ref&amp;gt;&lt;br /&gt;
&lt;br /&gt;
The protection claim consequently includes its conditions of use. These include the hazard, the quantity and distribution of agent, the expected activation sequence and the time for which protection is maintained. Changes to storage, ventilation or operating procedures can alter those conditions. The International Fire Engineering Guidelines connect continued building use and alterations with review of the original engineering assumptions.&amp;lt;ref name=&amp;quot;I-7b0907c015&amp;quot; /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== See also ==&lt;br /&gt;
* [[Foam expansion ratio]]&lt;br /&gt;
* [[Foam proportioner]]&lt;br /&gt;
* [[Foam-water sprinkler system]]&lt;br /&gt;
&lt;br /&gt;
== Notes ==&lt;br /&gt;
&amp;lt;references /&amp;gt;&lt;br /&gt;
&lt;br /&gt;
== References ==&lt;br /&gt;
* Australian Building Codes Board. (2022). &amp;#039;&amp;#039;Fire Safety Verification Method Standard 2022&amp;#039;&amp;#039;.&lt;br /&gt;
* Cote, A. E., Grant, C. C., Hall, J. R., Jr., &amp;amp; Solomon, R. E. (Eds.). (2008). &amp;#039;&amp;#039;Fire Protection Handbook&amp;#039;&amp;#039; (20th ed.). National Fire Protection Association.&lt;br /&gt;
* National Research Council of Canada, International Code Council, Department of Building and Housing, &amp;amp; Australian Building Codes Board. (2005). &amp;#039;&amp;#039;International Fire Engineering Guidelines&amp;#039;&amp;#039; (2005 ed.). Australian Building Codes Board.&lt;br /&gt;
* Scheffey, J. L. (2002). Foam agents and AFFF system design considerations. In P. J. DiNenno, D. Drysdale, C. L. Beyler, W. D. Walton, R. L. P. Custer, J. R. Hall, Jr., &amp;amp; J. M. Watts, Jr. (Eds.), &amp;#039;&amp;#039;SFPE Handbook of Fire Protection Engineering&amp;#039;&amp;#039; (3rd ed., chapter 4-4, pp. 4-88–4-122). National Fire Protection Association.&lt;br /&gt;
&lt;br /&gt;
[[Category:Fire Suppression]]&lt;/div&gt;</summary>
		<author><name>Thomas</name></author>
	</entry>
</feed>